You are on page 1of 2

PRODUCT DATASHEET

1-800-383-7323 / USA USA/CAN 1-800-383-7323 1-800-383-7323 / CANADA www.energizer.com

ENERGIZER E91
Classification: Chemical System: Designation: Nominal Voltage: Nominal IR: Operating Temp: Typical Weight: Typical Volume: Jacket: Shelf Life: Terminal:

Specifications
Alkaline Zinc-Manganese Dioxide (Zn/MnO 2) No added mercury or cadmium ANSI-15A, IEC-LR6 1.5 volts 150 to 300 milliohms (fresh) -18C to 55C (0F to 130F) 23.0 grams (0.8 oz.) 8.1 cubic centimeters (0.5 cubic inch) Plastic Label 10 years at 21C Flat Contact

AA

Industry Standard Dimensions


mm (inches)

14.50 (0.571) 13.50 (0.531) 5.50 (0.217) Maximum (+) 1.00 (0.039) Minimum

Milliamp-Hours Capacity
Continuous discharge to 0.8 volts at 21C
3000 Capacity (mAh)
50.50 (1.988) 49.50 (1.949)

2500 2000 1500 1000 500 0 25 100 250 500

(-) 0.10 (0.004) Typical 7.00 (0.276) Minimum

Discharge (mA)

Device Selection Guide:


Digital Camera Photoflash Games, CD's, MD's Tape Player Lighting Toy Remote Control Radio Clock

Battery Selection Indicator High Drain Devices

Moderate Drain Devices

Low Drain Devices Important Notice

This data sheet contains typical information specific to products manufactured at the time of its publication. Energizer Holdings, Inc. - Contents herein do not constitute a warranty.

Engineering Data
Form No. EBC - 1102O Page 1 of 2

PRODUCT DATASHEET

Engineering Data
1-800-383-7323 USA/CAN www.energizer.com

ENERGIZER E91
Constant Power Performance
Typical Characteristics (21C)
100 1000

AA
Typical Characteristics (21C)

Constant Current Performance

Service (hours)

Service (hours)

100

10 0.9 Volts 1.2 Volts 1 100 Discharge (mW) 1000

10

0.8 Volts 1.0 Volts 1.2 Volts 10 100 Discharge (mA) 1000

Constant Power Performance


Discharge Characteristics (21C)
1.6 1.5 Voltage (CCV) 1.3 1.2 1.1 1.0 0.9 0.8 0 8 16 Service (hours) 24 32 250 mW 100 mW Voltage (CCV) 1.4

Constant Current Performance


250 mA Discharge (-20C / 0C / 21C)
1.6 1.5 1.4 1.3 1.2 1.1 1.0
0.9

(21C)

(0C) (-20C) 0 2 4 Service (hours) 6 8

0.8

Industry Standard Tests (21C)


REMOTE 24 ohm 15 sec/min 8 hrs/day Voltage (CCV) RADIO 43 ohm 4 hrs/day TOOTHBRUSH PORTABLE LIGHTING TOY 500 mA 2/13 min 24 hrs/day 3.3 ohm LIF 3.9 ohm 1 hr/day Voltage (CCV)

1.6 1.4 1.2 1.0 0.8 0 20


CD/GAMES 250 mA 1 hr/day

1.6 1.4 1.2


1.0

RADIO REMOTE 40 60 80 100

0.8 0

BRUSH 2 4

LIGHT 6 8
Service (hours)

TOY 10

Service (hours)

DIGITAL AUDIO 100 mA 1 hr/day

DIGITAL CAMERA 1.5K/.65K mW 2./1./27.9s 10x

PHOTOFLASH 1K mA 10 sec/min 1 hr/day

1.6 1.4 1.2 1.0 0.8 0 7 14


Service (hours)

1.6 TAPE PLAYER


Voltage (CCV)

Voltage (CCV)

1.4 1.2 1.0 0.8 0 20 40 60 80 100 120


Service (minutes)

PHOTO CAMERA

CD/GAMES 21 28

This data sheet contains typical information specific to products manufactured at the time of its publication. Energizer Holdings, Inc. - Contents herein do not constitute a warranty.

Important Notice

Form No. EBC - 1102O

Page 2 of 2