You are on page 1of 6

ISO 9001

ISO 14001

R407C
Printed in Japan (H) HR-E577R Sep. 2010

NEW The High-efficiency Air-cooled Chiller "H series"


The air-cooled chiller "H series" with improved efficiency and functionality by several advanced technologies. This series with the world's best standard A-type screw compressor and newly designed shell and tube heat exchanger that have powerful cooling ability, low noise, low vibration, high efficiency and high reliability is the perfect answer to all your needs!!

Improved heat-exchange performance by using inverse M type Air Side Heat Exchanger

Protection Net (standard equipment)

Acoustic Chamber (standard equipment)

Product Series
RCUG-AHYZ1
Nominal Capacity Range (50Hz)

RCU-AHYZ1
Nominal Capacity Range (50Hz) 116 kW to 1,146 kW 33 USRT to 326 USRT 99,760 kcal/h to 985,560 kcal/h

R407C

110 kW to 1,089 kW 31 USRT to 310 USRT 94,600 kcal/h to 936,540 kcal/h

E nhanced Line-up

~up to 400 HP~

Wide Line-up
To meet the need for air conditioning systems for large facilities and the demand for higher capacity industrial cooling systems.

H igh-performance A-type Screw Compressor P recise Capacity Control Technology E xcellent Control Function
1

RCUG-AHYZ1

R407C
RCU-AHYZ1

H ighly Reliable Shell and Tube Heat Exchanger


2

Technical Features

H igh-performance A-type Screw Compressor ~Newly Designed~


Built-in Cyclone Oil Separator
Low oil carrying-out is realized and reduction of heat transfer efficiency is minimized.

P recise Capacity Control Technology


Continuous Capacity Control
The temperature of the chilled water outlet can be kept at the set temperature 1C by continuous capacity control, so it is suitable for industrial use.
Load-up signal
12sec.

High Technology by Internal Manufacture


Because all manufacturing processes, from rotor manufacturing to unit assembly, are done internally, exceptional reliability is achieved.
8

Start

60sec.

When there is a big difference between set temperature and actual temperature. Load-up signal Inlet water temperature Outlet water temperature Neutral zone standard

Capacity Controller Structural Outline


(HITACHI Patented System)
Load-up Load-down
Slide Valve Bypass Gas Pd Suction Gas Rotor SV1

Inlet water temperature Outlet water temperature 6 4

Slide Valve Bypass Gas

2sec. 60sec.

Low Pressure Gas Ps

Low Pressure Gas Ps

Pd Suction Gas Rotor SV1

New Screw Compressor Operation Image

SV3 SV2

SV3 SV2

Stop
A given load status is maintained. Load-down signal
2sec. 60sec.

Stop temperature standard Lapsed time

High Pressure Oil

High Pressure Oil

No outside pump is required due to the reliable differential-pressure oil-feeding system.


This oil-feeding system, which does not use any electrical mechanism, prevents the compressor from being damaged and maintains long-term stable operation.

Discharged Gas Suctioned Refrigerant Gas

Cyclone Oil Separator

The inlet water temperature is detected at a stop, and it is restarted by a rise in inlet water temperature.

Pd: Discharge pressure, Ps: Suction pressure, SV1,2,3 : Solenoid valve : Valve open : Valve close

Screw Rotor

E xcellent Control Function


Building Management System (BMS)
Hitachi uses Building Management System through LONWORKS . For chiller air-conditioning, Hitachi provides its own central station system. No complicated work is necessary.
R

Oil Oil Reservoir Differential Pressure Lubrication Mechanism

* : "LONWORKS
BMS System

" is a trademark of Echelon Corporation registered in the United States and other countries.

Simple Structure with a Small Number of Parts


Whereas the number of main parts for the casing, compression mechanism and capacity control mechanism of a reciprocating compressor is 268, that of a screw compressor is only 27, just one tenth of the number ! A structure with so few parts offers high reliability and easy maintenance.

(Supplied by BMS Maker)

List of Functions
*

Remote Setting
Other Building Equipment

ON / OFF Operation Chilled Water Temperature (Inlet or Outlet)


Remote Monitor

G/W communication adapter (option)


G/W communication adapter (option) can be connected up to 4 units.

ON / OFF Status Setting Chilled Water Temperature (Inlet or Outlet) Current Water Temperature of Inlet and Outlet Alarm Code

Low Vibration Level


No exclusive vibration control equipment is necessary by using low-vibration screw compressor.

Vibration Comparison
Type
Comp. speed (rpm) 50/60Hz Full amplitude At leg of comp. At base frame At leg of comp. At base frame

* In addition, up to 8 units can be connected using the G/W communication


Equipment below the dotted line is provided by HITACHI

adapter for the Hitachi Chiller Unit signal (RS485).

Reciprocating 1,430 / 1,720 20-30 20 23.8 / 28.7 23.8 / 28.7

Screw 2,880 / 3,470 5 -8 Less than 10 48.5 / 57.8 48 / 57.8

H ighly Reliable Shell and Tube Heat Exchanger ~Newly Designed~


Dry expansion cooler system Low environmental impact: refrigerant quantity reduced by 60% from the current unit Perfect matching with the chiller unit due to our own design - Downsized by redesigned heat-transfer tube - Improved efficiency by optimized refrigerant distribution

Vib. frequecy

Acceleration energy

Screw: 1/5 of reciprocating type

R407C
Model Power Source Nominal Cooling Capacity*1 Capacity Control Outer Dimensions Net Weight Refrigerant Type Flow Control Number of Circuits Type Compressor Model Quantity Heat Exchanger Fan Motor Power Intput Quantity Evaporator Condenser Condenser Fan kW Height Width Depth kW USRT kcal/h % mm kg

RCUG40AHYZ1 110 31 94,600

RCUG50AHYZ1 RCUG60AHYZ1 Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz 136 39 170 48

RCUG75AHYZ1 181 51 155,660

RCUG100AHYZ1 272 77 233,920

RCUG150AHYZ1 RCUG180AHYZ1 RCUG200AHYZ1 RCUG120AHYZ1 Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz 340 97 292,400 100~15(7.5)*2, 0 2,170 1,940 4,490 3,280 363 103 510 145 544 155 467,840

RCUG240AHYZ1 680 193 584,800 100~15(7.5)*2, 0 2,170 1,940 9,080(min.) 2 x 3,280

116,960 146,200 Continuous Capacity Control 100~15, 0 2,170 1,940 2,390 1,830 R407C 2,170 1,940 2,390 1,870

312,180 438,600 Continuous Capacity Control 2,170 1,940 4,490 3,320 R407C 2,170 1,940 6,590 4,865

100~15(5)*2, 0 2,170 1,940 6,590 4,900

2,170 1,940 2,390 1,790

2,170 1,940 2,390 1,890

2,170 1,940 4,490 3,210

Thermal Expansion Valve 1 Semi-Hermetic Screw Type 40ASCCW-Z 50ASCCW-Z 1 Cross Fin Type Direct Drive Propeller Fan 1.1 4 1.1 4 1.1 4 1.1 4 1.1 8 1.1 8 8 60ASCCW-Z 60ASCCW-Z 50ASCCW-Z 2 60ASCCW-Z 2

Thermal Expansion Valve 3 Semi-Hermetic Screw Type 60ASCCW-Z 60ASCCW-Z 3 60ASCCW-Z 4 60ASCCW-Z 4

Cross Fin Type Direct Drive Propeller Fan 1.1 1.1 12 1.1 12

1.1 2x8

Safety Devices Shipping Dimensions Shipping Weight Piping Connections for Water Side Heat Exchanger Connection Hole Inlet Outlet mm Height Width Depth

mm kg

Shell-and-Tube Type Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 2,510 2,510 2,510 2,510 2,190 2,600 2,000 2,190 2,600 2,040 2,190 2,600 2,080 2,190 2,600 2,100

2,510 2,190 4,700 3,610

Shell-and-Tube Type Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 2,510 2,510 2,510 2,510 2,190 4,700 3,680 2,190 4,700 3,720 2,190 6,800 5,500 2,190 6,800 5,535

2,510 2,190 2 x 4,700 2 x 3,680

With 90 Inner Diameter Companion Flange 233 x 140 3 x48; 2 x75

With 142 Inner Diameter Companion Flange 233 x 140 3 x48; 64; 52; 2 x75 2 x 233 x 140 6 x48; 2 x64; 2 x52; 4 x75

Main Power (square orifice) Circuit

Model Power Source Nominal Cooling Capacity* Capacity Control Outer Dimensions Net Weight Refrigerant Type Flow Control Number of Circuits Type Compressor Model Quantity Condenser
Heat Exchanger Height Width Depth
1

RCUG270AHYZ1

RCUG300AHYZ1 RCUG330AHYZ1 Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz 726 206 624,360 873 248 750,780

RCUG350AHYZ1 907 258 780,020

RCUG400AHYZ1 RCUG360AHYZ1 RCUG380AHYZ1 Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz
1,020 290 877,200 1,055 300 907,300

NOTES: 1. The nominal cooling capacities are based on the following conditions. (*1) Chilled Water Inlet / Outlet Temperature: 12C / 7C Condenser Air Inlet Temperature: 35C(DB) 2. The units greater than 240AHYZ1 including 240AHYZ1 consist of two modules and are separately shipped. The common chilled water piping (Filed-Supplied) between each water cooler shall be directly connected at site. 3. Water Flow 1) RCUG240, 300, 360, 400AHYZ1 It is necessary to control the common water flow volume to each cooler. 2) RCUG270, 330, 350, 380AHYZ1 The chilled water flow rate is different between No.1 & No.2 units. It is necessary to control the water flow volume of each unit with adjusting valves (Filed-Supplied). 4. It is required to connect electrical control wires between No.1 & No.2 units for the unit greater than 240AHYZ1 including 240AHYZ1. 5. ( ) marked with *2 is available by selection switch.

kW USRT kcal/h % mm kg

703 200 604,580 100~15(7.5)*2, 0 2,170 1,940 9,080(min.) 3,320 + 3,280

1,089 310 936,540

Continuous Capacity Control


2,170 1,940 9,080(min.) 2 x 3,320 2,170 1,940 11,180(min.) 4,865 + 3,320

100~15(6)*2, 0 2,170 1,940 11,180(min.) 4,900 + 3,320 2,170 1,940 13,280(min.) 2 x 4,865

Continuous Capacity Control 100~15(7.5)*2, 0 2,170


1,940 13,280(min.) 4,900 + 4,865 R407C Thermal Expansion Valve 2,170 1,940

13,280(min.) 2 x 4,900

R407C Thermal Expansion Valve


4 60ASCCW-Z 4 5

6 60ASCCW-Z 60ASCCW-Z Semi-Hermetic Screw Type 60ASCCW-Z 6 Cross Fin Type Direct Drive Propeller Fan 1.1 12 + 12 Shell-and-Tube Type

Semi-Hermetic Screw Type 60ASCCW-Z 60ASCCW-Z


5

60ASCCW-Z

Cross Fin Type kW


1.1 8+8 1.1 2x8

Condenser Fan Fan Motor Power Intput Quantity Evaporator

Direct Drive Propeller Fan

1.1

12 + 8

1.1 12 + 8

1.1 2 x 12

1.1 2 x 12

Safety Devices
Height Width Depth

Shipping Dimensions Shipping Weight

mm kg Inlet Outlet mm

Shell-and-Tube Type Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 2,510 2,510 2,510 2,510 2,190 2,190 2,190 2,190
2 x 4,700 2 x 4,700 2 x 3,720 6,800 + 4,700 5,500 + 3,720 3,720 + 3,680

Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, LowPressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve

2,510

2,510

2,510

2,190 2 x 6,800 2 x 5,500

2,190 2 x 6,800 5,535 + 5,500


With 142 Inner Diameter Companion Flange 2 x 233 x 140 6 x48; 2 x64; 2 x52; 4 x75

2,190 2 x 6,800 2 x 5,535

6,800 + 4,700
5,535 + 3,720

Working Range
Item Chilled Water Outlet Temperature Condenser Air Inlet Temperature (DB) Standard 5~15C 5~43C 6

Piping Connections for Water Side Heat Exchanger Connection Hole

With 142 Inner Diameter Companion Flange 2 x 233 x 140


6 x48; 2 x64; 2 x52; 4 x75

Main Power (square orifice) Circuit

Model Power Source Nominal Cooling Capacity*1 Capacity Control Outer Dimensions Net Weight Refrigerant Type Flow Control Number of Circuits Type Compressor Model Quantity Condenser Heat Exchanger Condenser Fan Fan Motor Power Intput Quantity Evaporator kW Height Width Depth kW USRT kcal/h % mm kg

RCU40AHYZ1 116 33 99,760

RCU50AHYZ1 RCU60AHYZ1 Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz 143 41 179 51

RCU75AHYZ1 191 54 164,260

RCU100AHYZ1 286 81 245,960

RCU150AHYZ1 RCU180AHYZ1 RCU120AHYZ1 RCU200AHYZ1 Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz 358 102 307,880 100~15(7.5)*2, 0 382 109 537 153 573 163 492,780

RCU240AHYZ1 716 204 615,760 100~15(7.5)*2, 0 2,170 1,940 9,080(min.) 2 x 3,280

122,980 153,940 Continuous Capacity Control 100~15, 0 2,170 1,940 2,390 1,830 R22 2,170 1,940 2,390 1,870

461,820 328,520 Continuous Capacity Control 2,170 1,940 4,490 3,320 R22 2,170 1,940 6,590 4,865

100~15(5)*2, 0 2,170 1,940 6,590 4,900

2,170 1,940 2,390 1,790

2,170 1,940 2,390 1,890

2,170 1,940 4,490 3,210

2,170 1,940 4,490 3,280

Thermal Expansion Valve 1 Semi-Hermetic Screw Type 40ASCCW-Z 50ASCCW-Z 1 Cross Fin Type Direct Drive Propeller Fan 1.1 4 1.1 4 1.1 4 1.1 4 1.1 8 1.1 8 8 60ASCCW-Z 60ASCCW-Z 50ASCCW-Z 2 60ASCCW-Z 2

Thermal Expansion Valve 3 Semi-Hermetic Screw Type 60ASCCW-Z 60ASCCW-Z Cross Fin Type Direct Drive Propeller Fan 1.1 1.1 12 1.1 12 1.1 2x8 3 60ASCCW-Z 4 60ASCCW-Z 4

Safety Devices Shipping Dimensions Shipping Weight Piping Connections for Water Side Heat Exchanger Connection Hole Inlet Outlet mm Height Width Depth

mm kg

Shell-and-Tube Type Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 2,510 2,510 2,510 2,510 2,190 2,600 2,000 2,190 2,600 2,040 2,190 2,600 2,080 2,190 2,600 2,100

2,510 2,190 4,700 3,610

Shell-and-Tube Type Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 2,510 2,510 2,510 2,510 2,190 4,700 3,680 2,190 4,700 3,720 2,190 6,800 5,500 2,190 6,800 5,535

2,510 2,190 2 x 4,700 2 x 3,680

With 90 Inner Diameter Companion Flange 233 x 140 3 x48; 2 x75

With 142 Inner Diameter Companion Flange 233 x 140 3 x48; 64; 52; 2 x75 2 x 233 x 140 6 x48; 2 x64; 2 x52; 4 x75

Main Power (square orifice) Circuit

Model Power Source Nominal Cooling Capacity* Capacity Control Outer Dimensions Net Weight Refrigerant Type Flow Control Number of Circuits Type Compressor Model Quantity Condenser
Heat Exchanger Height Width Depth
1

RCU270AHYZ1

RCU300AHYZ1 764 217 657,040

RCU330AHYZ1 919 261 790,340

RCU350AHYZ1 955 272 821,300

RCU360AHYZ1 1,074 305 923,640

RCU380AHYZ1 1,110 316 954,600

RCU400AHYZ1
1,146 326 985,560

NOTES: 1. The nominal cooling capacities are based on the following conditions. (*1) Chilled Water Inlet / Outlet Temperature: 12C / 7C Condenser Air Inlet Temperature: 35C(DB) 2. The units greater than 240AHYZ1 including 240AHYZ1 consist of two modules and are separately shipped. The common chilled water piping (Filed-Supplied) between each water cooler shall be directly connected at site. 3. Water Flow 1) RCU240, 300, 360, 400AHYZ1 It is necessary to control the common water flow volume to each cooler. 2) RCU270, 330, 350, 380AHYZ1 The chilled water flow rate is different between No.1 & No.2 units. It is necessary to control the water flow volume of each unit with adjusting valves (Filed-Supplied). 4. It is required to connect electrical control wires between No.1 & No.2 units for the unit greater than 240AHYZ1 including 240AHYZ1. 5. ( ) marked with *2 is available by selection switch.

Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz kW USRT kcal/h % mm kg
740 210 636,400 100~15(7.5)*2, 0

Main (AC 3) 380, 415V / 50Hz, Control (AC 1) 220, 240V / 50Hz

Continuous Capacity Control


2,170 1,940 9,080(min.) 2 x 3,320 2,170 1,940 11,180(min.) 4,865 + 3,320

2,170 1,940 9,080(min.)

100~15(6)*2, 0

Continuous Capacity Control


2,170 1,940 11,180(min.) 2,170 1,940 13,280(min.) 2 x 4,865

100~15(7.5)*2, 0 2,170
1,940 13,280(min.) 4,900 + 4,865 R22

2,170 1,940 13,280(min.) 2 x 4,900

3,320 + 3,280

4,900 + 3,320

R22 Thermal Expansion Valve


4 60ASCCW-Z 4 5

Thermal Expansion Valve 6 60ASCCW-Z 5 60ASCCW-Z Semi-Hermetic Screw Type 60ASCCW-Z 6 Cross Fin Type 1.1 1.1 12 + 8 1.1 2 x 12 Direct Drive Propeller Fan 1.1 12 + 12 Shell-and-Tube Type 1.1 2 x 12 60ASCCW-Z

Semi-Hermetic Screw Type 60ASCCW-Z 60ASCCW-Z Cross Fin Type

Fan Motor Power Intput Quantity Evaporator

Condenser Fan kW

1.1 8+8

1.1 2x8

Direct Drive Propeller Fan

12 + 8

Safety Devices
Height Width Depth

Shell-and-Tube Type Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve 2,510 2,510 2,510 2,510 mm kg
2,190 2 x 4,700 3,720 + 3,680 2,190 2 x 4,700 2 x 3,720 2,190 6,800 + 4,700 5,500 + 3,720 2,190 6,800 + 4,700 5,535 + 3,720

Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, LowPressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve

2,510 2,190

2,510

2,510 2,190

Shipping Dimensions Shipping Weight

2,190 2 x 6,800 5,535 + 5,500

2 x 6,800 2 x 5,500

2 x 6,800 2 x 5,535

Working Range
Item Chilled Water Outlet Temperature Condenser Air Inlet Temperature (DB) Standard 5~15C 5~43C 8

Piping Connections for Water Side Heat Exchanger Connection Hole

Inlet Outlet mm

With 142 Inner Diameter Companion Flange 2 x 233 x 140


6 x48; 2 x64; 2 x52; 4 x75

With 142 Inner Diameter Companion Flange 2 x 233 x 140 6 x48; 2 x64; 2 x52; 4 x75

Main Power (square orifice) Circuit

Dimensional Data
R407C RCUG40, 50, 60 and 75AHYZ1 R22 R407C RCUG240, 270 and 300AHYZ1 R22
2,390 2,100 Air Side Heat Exchanger 1,900 Air Discharge

RCU40, 50, 60 and 75AHYZ1


290

RCU240, 270 and 300AHYZ1


4,490 290 4,200

9,080(min.) 100(min.)

4,490 4,200 Air Side Heat Exchanger 290

1,900 Air Discharge

Air Side Heat Exchanger

2,170

2,170

Air Inlet Electric Control Box Water Outlet Temperature (With 90mm Inner Diameter Frange) 350

Air Inlet

Air Inlet Water Outlet Temperature (With 142mm Inner Diameter Frange) 264 430 485

Air Inlet Electric Control Box Rigging Holes (8-50) Mounting Holes (12-26) (1,945) 2,050 52.5

300

Screw Type Compressor Water Inlet Temperature (With 90mm Inner Diameter Frange) Earth Connection Terminal M10 100 1,900 700 1,110

485

Rigging Holes (4-50) Mounting Holes (4-26)

150

52.5

(1,945) 2,050

52.5

Earth Connection Terminal M10 1,950 4,200 No.1 Water Outlet 1,140 2,090

Screw Type Compressor 1,950

150

Earth Connection Terminal M10 1,950 4,200 No.2 Water Outlet 2,090

1,950 No.2 Water Inlet

Water Inlet Temperature (With 142mm Inner Diameter Frange) 52.5

No.1 Water Inlet 2,210

71

160

71

160

Fan NOTE: It should be surpport the water pipings properly to avoid its weight press on the unit directly.

Wiring Hole for Power Supply

Wiring Hole for Power Supply

Fan

NOTES: 1. It should be surpport the water pipings properly to avoid its weight press on the unit directly. 2. These chillers consist of unit No.1 & No.2 and they are supplied separately when dispatched. 3. Water Flow For RCU(G)240,300AHYZ1: It is necessary to control the same water quantity to each cooler. For RCU(G)270AHYZ1: The chilled water flow rate is different between No.1 & No.2 unit... It is necessary to control the water quantity of each unit with adjusting valves (Field-Supplied). 4. It needs to field connect the control wiring between the No.1 & No.2.

100

R407C RCUG100, 120 and 150AHYZ1 R22

500

R407C RCUG330 and 350AHYZ1 R22

RCU100, 120 and 150AHYZ1


290 4,490 4,200 1,900 Air Side Heat Exchanger Air Discharge

500

100

RCU330 and 350AHYZ1


6,690 11,180(min.) 100(min.) 4,490 4,200 Air Side Heat Exchanger 290 Air Discharge 1,900 6,300

290

Air Side Heat Exchanger

Air Inlet 2,170 Water Outlet Temperature (With 142mm Inner Diameter Frange) Water Inlet Temperature (With 142mm Inner Diameter Frange) Earth Connection Terminal M10 150 100 1,140 1,950 2,090 Screw Type Compressor 1,950 52.5 (1,945) 2,050 350

Air Inlet Electric Control Box 2,170

Air Inlet Water Outlet Temperature (With 142mm Inner Diameter Frange) P 1,950 264 430

Air Inlet Electric Control Box Rigging Holes (8-50) Mounting Holes (14-26) (1,945) 2,050 52.5

485

300

Rigging Holes (4-50) Mounting Holes (6-26) 52.5 100

485

150

Earth Connection Terminal M10 1,950

2,100 No.1 Water Outlet

Screw Type Compressor 1,950 No.1 Water Inlet 2,120

150

Earth Connection Terminal M10 1,950 No.2 Water Outlet 2,090

Water Inlet Temperature (With 142mm Inner 52.5 Diameter Frange) No.2 Water Inlet

71

160

71

160

3,125

2,150

Fan Wiring Hole for Power Supply

NOTE: It should be surpport the water pipings properly to avoid its weight press on the unit directly.

Wiring Hole for Power Supply

Fan

NOTES: 1. It should be surpport the water pipings properly to avoid its weight press on the unit directly. 2. These chillers consist of unit No.1 & No.2 and they are supplied separately when dispatched. 3. Water Flow For RCU(G)330,350AHYZ1: The chilled water flow rate is different between No.1 & No.2 unit. It is necessary to control the water quantity of each unit with adjusting valves (Field-Supplied). 4. It needs to field connect the control wiring between the No.1 & No.2. 5. In the No.2 unit, the data with the P mark is 300mm.

R407C RCUG180 and 200AHYZ1 R22

500

500

R407C RCUG360, 380 and 400AHYZ1 R22


6,590 6,300 1,900 Air Side Heat Exchanger Air Discharge 290

RCU180 and 200AHYZ1


290

RCU360, 380 and 400AHYZ1


6,590 6,300 13,280(min.) 100(min.) Air Side Heat Exchanger 6,590 6,300 Air Side Heat Exchanger 290 1,900

Air Discharge Air Inlet Water Outlet Temperature (With 142mm Inner Diameter Frange) 264 430 Air Inlet Electric Control Box Rigging Holes (8-50) (1,945) 2,050 Mounting Holes (16-26) 52.5

485

Water Outlet Temperature (With 142mm Inner Diameter Frange) Water Inlet Temperature (With 142mm Inner Diameter Frange) 150 Earth Connection Terminal M10 1,950 160 3,125 2,100 Screw Type Compressor 1,950 2,150 Fan 430 485

2,170

Electric Control Box Earth Connection Terminal M10 1,950 Screw Type Compressor 1,950 Earth Connection Terminal M10 1,950

2,170

Air Inlet

Air Inlet

264

Rigging Holes (4-50) Mounting Holes (8-26) 100

150

2,100

150

2,100

1,950

Water Inlet Temperature (With 142mm Inner Diameter Frange) 52.5 No.2 Water Inlet

52.5

(1,945) 2,050

52.5

No.1 Water Outlet 71 160 3,125 2,150

No.1 Water Inlet 4,105

No.2 Water Outlet 2,150

71

Wiring Hole for Power Supply

NOTES: 1. It should be surpport the water pipings properly to avoid its weight press on the unit directly. 2. Water connection flange (142mm) are supplied by factory with the unit.

Wiring Hole for Power Supply

Fan

NOTES: 1. It should be surpport the water pipings properly to avoid its weight press on the unit directly. 2. These chillers consist of unit No.1 & No.2 and they are supplied separately when dispatched. 3. Water Flow For RCU(G)360,400AHYZ1: It is necessary to control the same water quantity to each cooler. For RCU(G)380AHYZ1: The chilled water flow rate is different between No.1 & No.2 unit. It is necessary to control the water quantity of each unit with adjusting valves (Field-Supplied). 4. It needs to field connect the control wiring between the No.1 & No.2.

100

500

500

10