You are on page 1of 34

Click Here

General Technical

Burst Test

Leak Test

Hardness Test

Impulse Test

Vibration Test

The Fitting Authority

4300 Catalog

General Technical

How To Order ................................................................................. U3


Standard Nomenclature (Seal-Lok, Triple-Lok, Ferulok, Intru-Lok, JIS and K4) ...................................................................................................... U3 Hydraulic Flange Nomenclature ............................................................................ U4 EO/EO-2 Nomenclature ......................................................................................... U5

Connectors for World Class Products ......................................... U6 Conformance Standards .............................................................. U9 Compatibility ............................................................................... U10
Media Compatability ............................................................................................ U10 Material Compatibility .......................................................................................... U10 Corrosion of Base Metals in Contact ................................................................... U12 O-Ring / Seal Material Selection.......................................................................... U13

Tube Selection ............................................................................. U14


Tube and Fitting Material Compatibility ................................................................ U14 Determining Tube Size ......................................................................................... U15 Recommended Flow Diameters .......................................................................... U17 Inch Tube Pressure Ratings ................................................................................. U19 Metric Tube Pressure Ratings .............................................................................. U21

Tube Fitting Pressure Drop ........................................................ U22 Fitting and Adapter Pressure Ratings ....................................... U24 Port Details .................................................................................. U25
ISO 6149-1 (Metric ORB) .................................................................................... U25 SAE J1926-1 (SAE-ORB) .................................................................................... U26 SAE Straight Thread Connector Use in MS33649 ............................................... U27 ISO 6162 / SAE J518 (Code 61/62)..................................................................... U28 ISO 1179-1 (BSPP) ............................................................................................. U29 ISO 9974-1 .......................................................................................................... U30 NPT / NPTF ......................................................................................................... U31

Port End Summary ...................................................................... U32


Tube-to-Port Pairings ............................................................................... U32

Seal-Lok ....................................................................................... U33


3161 Gas and Fluids Chart .................................................................................. U33 Chemical Compatibility Chart .............................................................................. U34

U2

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

How to Order Seal-Lok, Triple-Lok, Ferulok, Intru-Lok, JIS and K4


TFD Standard Nomenclature Construction
Box 1 Size Box 2 Shape or Style Box 3 Sub-Style Box 4 Type

Box 5 Material

1 to 4 sets of numbers from Box 1

Letter code from Box 2

Number/Letter code from Box 3

Number/Letter code from Box 4

Letter code from Box 5

Example: Steel Seal-Lok Adjustable Elbow Connector 3/8 O.D. (-6) Tube to 7/16-20 UNF (-4) ORB =
(See the shading in the boxes below for the construction of this example)
Box 1 Paired Tube and Port End Size Code Table Tube End Port End Port End Dash Size -2 -3 -4 -5 -6 -8 -10 -12 -14 -16 -20 -24 -32 Tube O.D. 1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8 1 1 1/4 1 1/2 2 Dash SAE Straight Thread Size -2 5/16-24 -3 3/8-24 -4 7/16-20 -5 1/2-20 -6 9/16-18 -8 3/4-16 -10 7/8-14 -12 1 1/16-12 -14 1 3/16-12 -16 1 5/16-12 -20 1 5/8-12 -24 1 7/8-12 -32 2 1/2-12 Dash NPTF Pipe Size Thread -2 1/8 -2 1/8 -2 1/8 -2 1/8 -4 1/4 -6 3/8 -8 1/2 -12 3/4 -12 3/4 -16 1 -20 1 1/4 -24 1 1/2 -32 2 Box 2 Shape or Style Straights B Nut F* Male Connector Long Male Connector FF* or Pipe Nipple Extra Long Connector FFF* or Long Pipe Nipple FN Cap G* Female Connector H Union HH Long Union Plug, Straight Thread, HPN* Hollow Hex LH Large Hex Union Plug, Straight Thread, PN* Hex Head T Sleeve or Ferrule TP Sleeve, Parange TR Tube Reducer T22 Mountie W Bulkhead Union WF Bulkhead Male WG Bulkhead Female Bulkhead Locknut for WLN Triple-Lok, Ferulok and Intru-Lok Bulkhead Locknut for WLNL Seal-Lok 90 Elbows C* Male Elbow Connector CC* Long Male Elbow CCC* Extra Long Male Elbow D Female Elbow E Union Elbow WE Bulkhead Union Elbow 45 Elbows N Union Elbow V* Male Elbow Connector WN Bulhead Union Elbow Tees J Union Tee M Female Run Tee O Female Branch Tee R* Male Run Tee S* Male Branch Tee WJ Bulkhead Branch Tee WJJ Bulhead Run Tee Cross K Union Cross Box 3 Sub-Style Modiers (Connectors, Swivels and Plugs) Connectors (a) 3 BSPT Port End 4** BSPP Port End, O-ring & RR 5** SAE Straight Thread Port End 8** Metric Port End, O-ring & RR 9 SAE-ORB with Metal Seal 42 BSPP Port End, "ED" Seal 47** BSPP O-ring Port, B2351 82 Metric Port End, "ED" Seal 87** ISO 6149 Port End J4 (e) Banjo Connection, BSPP, Soft Seal J8 (e) Banjo Connection, Metric, Soft Seal Swivel Unions (b) 6 Female Swivel Swivel Connectors (c) 63 BSPT Port, Swivel Connector 64** BSPP Port, Swivel Connector 642 BSPP, "ED" Seal, Swivel Connector 65** SAE-ORB, Swivel Connector 68** Metric Port, Swivel Connector 682 Metric Port, Swivel Connector 687** ISO 6149, Swivel Connector Straight Thread Plugs (d) (Modiers for P) 4, 5, 8, 9 and 87 as in Connectors above. Notes a. Modiers for Connectors as noted with asterisk in Box 2. b. Modier for C, V, R, S, H, E and J in Box 2. c. Modiers for F only in Box 2. d. Modiers for P only in PN and HPN in Box 2. e. Applies to 90 elbows and tees only.

6-4 C5L-S

Box 4 Fitting Type I Intru-Lok K4 60 Cone BSPP L** Seal-Lok P4 JIS 60 Cone T4 JIS 30 Flare U Ferulok X Triple-Lok

** Placing the letter O after these sub-style modiers and tting types will indicate that you would like an O-ring on that corresponding end. Dimensions and pressures for reference only, subject to change.

Box 5 Material Code B Brass Cupro-Nickel CUNI (ex. CUNI 70/30) D Dural (Aluminum) M Monel Steel w/zinc S plating Stainless Steel, SS 316/316L passivated

U3

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

How to Order 4-Bolt Hydraulic Flanges


TFD Standard Nomenclature Construction
Box 1 Flange Size Box 2 Connection Description Box 3 Shape Box 4 Flange Connection Type Box 5 Mounting Style Box 6 Material Box 7 Kit Designation

Box 1 Port / Tube / Pipe Flange Size


Symbol One- to twodigit codes Description Size in inches x 16

Box 3 Shape Description


Symbol Description None Block and Pad, Straight* E Elbow 90 H Barstock, Straight J Tee * The Block has O-ring and drilled mounting holes, while the Pad has no O-ring groove and tapped mounting holes.

One code is required if end connections are the same size. Two codes are required if they are different sizes (e.g., 16-12).

Box 2 Port / Tube / Pipe Connection Description


Symbol B3 CP1 CP2 FCC1 FCC2 FCCT1 FCCT2 FCS1 FCS2 G G3 G4 G5 P SP SPG SPG5 SPGG5 WSD1 WSD2 W4 W4S W5 W5S W6 W6S W7 W7S WB1 WB3 WB5 WB7 WBT WPL W W2 W3 or WB Description Braze Socket silver braze Connector Plate Code 61 Connector Plate Code 62 Flange Clamp, Captive Code 61 Flange Clamp, Captive Code 62 Flange Clamp, Captive with Tapped Holes Code 61 Flange Clamp, Captive with Tapped Holes Code 62 Flange Clamp, Split Code 61 Flange Clamp, Split Code 62 NPTF Port BSPT Port BSPP Port SAE Port Plug (blanking end) Spacer w/o Gage Ports Spacer w/ 1/4-18 NPTF Gage Port Spacer w/ 7/16-20 UNF Gage Port Spacer w/ 1/4-18 NPTF & 7/16-20 UNF Ports Weld Sadle Pipe Weld Saddle Tube Flat Weld Socket Tube Flat Weld Socket Tube (shallow) Flat Weld Socket Pipe Flat Weld Socket Pipe (shallow) Extended Weld Socket Tube Extended Weld Socket Tube (shallow) Extended Weld Socket Pipe Extended Weld Socket Pipe (shallow) Weld Butt Schedule 40 Weld Butt Schedule 80 Weld Butt Schedule 160 Weld Butt Schedule XXS Weld Butt Tank Pilot Weld Plate Weld Socket Weld Nipple Weld Nipple Weld Butt, Tube

Box 4 Flange Connection Type


Symbol Q1 Q1N Q2 Q2N Q1B Q1P Q2B Q2P QSB QSP Description Code 61 Flange Head w/ O-ring Groove Code 61 Flange Head w/o O-ring Groove Code 62 Flange Head w/ O-ring Groove Code 62 Flange Head w/o O-ring Groove Code 61 Flange Block w/ O-ring Groove and Drilled Mounting Holes Code 61 Flange Block w/o O-ring Groove and Drilled Mounting Holes Code 62 Flange Block w/ O-ring Groove and Drilled Mounting Holes Code 62 Flange Pad w/o O-ring Groove and Tapped Mounting Holes Square Flange Block w/ O-ring Groove and Drilled Mounting Holes Square Flange Pad w/o O-ring Groove and Tapped Mounting Holes

Box 5 Mounting Style


Symbol Omit M Description Inch Mounting Bolts (screws) Metric Mounting Bolts (screws)

Box 6 Material
Symbol S SX SS Description Steel, Zinc Plated (braze or weld parts may not be plated) Steel, Oil Dipped Stainless Steel

Box 7 Kit Designation


Symbol Omit K Description Flange Only Kit (O-ring, 4 bolts and washers)

Dimensions and pressures for reference only, subject to change.

U4

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

How to Order EO and EO-2 Fittings and Accessories


TFD Standard Nomenclature Construction
Box 1 Shape / Style Box 2 Tube Size (mm) Box 3 EO-2 Designator Box 4 Pressure Series Box 5 Port Size / Designator Box 6 Port Sealing Method Modier Box 7 Modier 1 Box 8 Material Box 9 Modier 2

Box 1 - Shape/Style Code Straights Tees AS Weld Connector EL Swivel Nut Run AS__/ Weld Flange ET Swivel Nut Branch BFG Square Flange Connector GMA1/ Union w/ Test Point, Pin DA Distance Adapter GMA3/ Union w/ Test Point, M16x2 DG101/ Rotary Union LEE Adjustable Run DG102/ Rotary Connector T Union DG107/ Rotary Bulkhead Union TEE Adjustable Branch DVGE Plain Bearing Rotary TH High Pressure Banjo EGE Swivel Nut Connector TR Reducer Union EGEO ISO 6149 Swivel Nut Connector WV Alternating Valve Cross ESV Weld Bulkhead Union G Union K Union Accessories GAI Female Connector GE Male Connector D Cutting Ring GEO ISO 6149 Connector DKA Metal Seal Ring GFS__/ Flange Connector DKI Pressure Gage Seal GR Reducer Union DOZ EO-2 Seal Ring GZ Swivel Union DPR Progressive Ring GZR Reducer Swivel Union E Insert MAV Gage Connector ED EOlastic Seal MAVE Swivel Nut Gage Connector FM EO-2 Functional Nut RED Tube End Reducer GM Bulkhead Locknut SKA Weld Adapter KD Plastic Seal SV Bulkhead Union KDS Elastomeric Seal VKA1/ Test Point Connector, Pin M Tube Nut VKA3/ Test Point Connector, M16x2 OR O-ring 90 Elbows PSR Progressive Ring (new) BFW Square Flange Connector R Tube DG103/ Rotary Union ROV Plug DG104/ Rotary Connector VH Insert DG108/ Rotary Bulkhead Union VKA Cap DVWE Plain Bearing Rotary VSTI Hollow Hex Plug Valves EW Swivel Nut SWVE Banjo RHD Union Check W Union RHV Connector Check WAS Weld Connector RHZ Connector Check WE Male Connector RHDI Female Check WEE Adjustable RVP Cartridge Check WFS__/ Flange Connector DV Low Pressure Shut Off WH High Pressure Banjo LD Medium Pressure Shut Off WSV Bulkhead Union VDHA High Pressure Shut Off Double 90 Elbows VDHB High Pressure Shut Off DG105/ Rotary Union KH 2-way Ball Valve DG106/ Rotary Connector KH3/23-way Ball Valve 45 Elbows WV Alternating Union Tee EV Swivel Nut VEE Adjustable

Box 2 Tube Size (mm) 04 05 06 08 10 12 14 15 16 18 20 22 25 28 30 35 38 42

Box 3 EO-2 Designator Z EO-2 Assy.

Box 5 Port Size / Designator (optional) Metric M_ Metric Parallel Metric Parallel M_X_ (Jump Size) M_X_keg Metric Taper NPT Inch 1/8NPT NPT Thread 1/4NPT NPT Thread 3/8NPT NPT Thread 1/2NPT NPT Thread 3/4NPT NPT Thread 1NPT NPT Thread 1 1/4NPT NPT Thread 1 1/2NPT NPT Thread SAE-ORB 7/16UNF Inch Parallel Thread 9/16UNF Inch Parallel Thread 3/4UNF Inch Parallel Thread 3/4UNF Inch Parallel Thread 7/8UNF Inch Parallel Thread 11/16UN Inch Parallel Thread 15/16UN Inch Parallel Thread 1 5/8UN Inch Parallel Thread 1 7/8UN BSPP/BSPT R_ BSPP R_/_keg BSPT Box 6 Port Sealing Method Modier (optional) ED EOlastic Seal OR ISO 6149 O-ring KDS Banjo Seal-Ring Box 7 Modier 1 (optional) OMD Without Nut and Sleeve FPM (omitted for VIT Stainless) Nitrile Seals (omitted for NBR Steel and Brass) Special Cracking __B Pressure (check valve) Box 8 Material Chromium 6 Free Steel, Zinc Clear Plated Brass Stainless Steel Zinc Plated (tube only)

Box 4 Pressure Series LL L S Very light Light Heavy

CF A3K MS 71 VZ

Box 9 Modier 2 (optional) X Unassembled

Dimensions and pressures for reference only, subject to change.

U5

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
This challenge has been met through a very intensive and cooperative effort by the member nations of sub-committee 4 of the ISO Technical Committee 131 (ISO/TC131). The subcommittee started this effort in 1989 and has completed development of performance based standards for the most widely used ports and tube/hose connections to limit proliferation, and strongly endorsing those with elastomeric seals to eliminate leakage in hydraulic systems. Five ports, four threaded and the four bolt ange, and four tube/ hose connections as shown on the following page (Fig. U1) have been standardized. The threaded ports and tube/hose connections are paired in the ISO 8434 series of tting standards as dened in the table below. To minimize proliferation in port usage and promote leak free connections, the sub-committee strongly endorses use of ISO 6149 port for all new designs by including the following statement in all port standards: For threaded ports and stud ends specied in new designs in hydraulic uid power applications, only ISO 6149 shall be used. Threaded ports and stud ends in accordance with ISO 1179, ISO 9974 and ISO 11926 shall not be used for new designs in hydraulic uid power applications. On the tube/hose connection side, only ISO 8434-3 (O-ring Face Seal) and ISO 8434-4 (24 cone with weld nipple) feature elastomeric seal for zero leak performance. Combining these with the ISO 6149 for the port connection leads to two (2) combinations (complete ttings) for use in leak-free world class products. They are: ISO 8434-3 ISO 8434-4 O-ring Face Seal and ISO 6149 Port 24 Cone With Soft Seal and ISO 6149 Port
Return To Index

Connectors For World Class Products


Connector Proliferation:
Today many different types of connectors are being used around the world. Most of these have come about through historical use and local preference for a certain design concept. Some connections of the North American origin such as four bolt ange, SAE straight thread and 37 are have found some degree of acceptance and use in Europe and Japan as a result of the exports of U.S. machinery to the regions after World War II. But, large majority of usage is made up of a variety of indigenous port and tube connections. A quick review of the commonly used connections around the world reveals that there are eight different port connections and eleven different tube/hose connections. Port Connections: NPTF SAE Straight Thread (UN/UNF) 4-Bolt Flange ISO 1179 (BSPP) ISO 9974 (Metric) Tube/Hose Connections: 37 Flare (SAE) 24 Flareless, Inch Threads (SAE) 60 Cone Swivel, NPSM (SAE) O-Ring Face Seal (SAE) 24 Cone, Metric (DIN) 60 Cone, BSPP (BSi) ISO 6149 (Metric Straight Thread O-ring Port) JIS-PT (BSPT) JIS-B2351 (BSPP similar to SAE) 30 Flare, BSPP (JIS) 24 Flareless, Metric (JIS) 60 Cone, BSPP (JIS) 60 Cone, Metric (JIS) 37 Flare, Metric (Russia)

The Challenge:
Leakage is no longer acceptable in world class products. Above proliferation, besides limiting availability and increasing cost, increases leakage potential through misapplications. Therefore, the challenge facing the uid power industry is two fold eliminate leakage and minimize proliferation.

Meeting The Challenge:

For large port connections, the four bolt ange connection per ISO 6162 (SAE J518 is included in ISO 6162) remains widely used and the recommended connection.

Tube/Hose Connection Application For All Designs Port Metric ISO 6149 (SAE J2244) BSPP ISO 1179 (DIN 3852-2) Not for New Designs in Hydraulic Fluid Power Metric ISO 9974 (DIN 3852-1) UN/UNF ISO 11926 (SAE J1926) 24 Cone Flareless (DIN) (Bite Type) ISO 8434-1 37 Flare (Inch Threads) ISO 8434-2 ORFS ISO 8434-3 24 Cone Weld Nipple ISO 8434-4*

ISO 8434-1

ISO 8434-2

ISO 8434-4*

ISO 8434-1

ISO 8434-4*

ISO 8434-2

Table U1 ISO Standard Port and Tube/Hose Connection Combinations * Will be included in ISO 8434-1 at the next revision.
Dimensions and pressures for reference only, subject to change.

U6

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Tube / Hose End Summary


Tube / Hose End Type Seal-Lok O-Ring Face Seal Illustration Pressure Dynamic Pressure Static Seal Reliability
(in Rigid Systems)

Vibration Resistance

Ease of Ease of Installation Maintenance Reusability

Temperature

Excellent

Excellent

Excellent

Very Good

Excellent

Excellent

Excellent

Limited by Seal

Triple-Lok 37 Flare

Very Good

Very Good

Good

Good

Good

Very Good

Good

Excellent

Ferulok Inch Bite Type

Very Good

Very Good

Very Good

Very Good

Good

Good

Very Good

Excellent

EO Metric Bite Type

Excellent

Excellent

Very Good

Very Good

Good

Good

Very Good

Excellent

EO-2 Soft Seal Metric Bite Type

Excellent

Excellent

Excellent

Very Good

Very Good

Good

Excellent

Limited by Seal

Intru-Lok Brass Flareless

Fair (Low)

Fair (Low)

Very Good

Good

Good

Good

Good

Excellent

JIS 30 Flare

Good

Good

Very Good

Not Applicable

Very Good

Very Good

Very Good

Limited by Seal

JIS 60 Cone B8363

Good

Good

Very Good

Not Applicable

Very Good

Very Good

Very Good

Limited by Seal

Komatsu 30 Flare

Good

Good

Very Good

Not Applicable

Very Good

Very Good

Very Good

Limited by Seal

K4 BSP Adapters

Good

Good

Very Good

Not Applicable

Very Good

Very Good

Very Good

Limited by Seal

NPSM (Swivel)

Good

Good

Very Good

Not Applicable

Good

Very Good

Very Good

Limited by Seal

U7

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Port End Summary


Port End Type and Seal Style Tapered (NPT, NPTF, BSPT and Metric Taper) Illustration Pressure Dynamic Pressure Static Temperature Positioning Contamination Seal Reliability Reusability Fluid Compatibility

Poor

Good

Excellent

Poor

Poor

Poor

Poor

Excellent

O-Ring in Chamfer (SAE J1926, ISO 6149 and JIS B2351) Spot Face with ED Seal (ISO 1179-2 and ISO 9974-2) Spot Face with Bonded Seal (ISO 1179 and ISO 9974) Spot Face with Cutting Face (ISO 1179-4 and ISO 9974-3)

Excellent

Excellent

Limited by Seal

Excellent

Very Good

Excellent

Excellent

Limited by Seal

Excellent

Excellent

Limited by Seal

Not Applicable

Very Good

Excellent

Excellent

Limited by Seal

Good

Good

Good

Not Applicable

Very Good

Good

Excellent

Limited by Seal

Poor

Fair

Excellent

Not Applicable

Fair

Poor

Poor

Excellent

Spot Face with O-Ring and Retaining Ring (ISO 1179-3)

Good

Good

Good

Excellent

Very Good

Good

Excellent

Limited by Seal

Spot Face with Hard Metal Seal (ISO 1179 and ISO 9974) Spot Face with Soft Metal Seal (ISO 1179 and Iso 9974 with copper gasket)

Poor

Fair

Excellent

Not Applicable

Fair

Poor

Poor

Excellent

Poor

Fair

Good

Not Applicable

Very Good

Poor

Fair

Excellent

4 Bolt Flange (SAE J518 and ISO 6162)

Excellent

Excellent

Good

Good

Very Good

Good

Excellent

Limited by Seal

4 Bolt Flange (ISO 6164)

Excellent

Excellent

Good

Good

Good

Good

Excellent

Limited by Seal

U8

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Conformance to Applicable Specications and Approvals for TFD Products


By Product Type or Subject
Fittings Seal-Lok Metric Seal-Lok Triple-Lok Specications SAE J1453 ISO 8434-3 SAE J514 MIL-F-18866, MS Sheets MS51500 - MS51534 BS43687, part 4 ISO 8434-2 SAE J514 MIL-F-18866 MS Sheets MS51811 - MS51843* U.S. Coast Guard - meet applicable requirements of ASTM F1387 DIN 3861 ISO 8434-1-4, ISO 8434-4 Approvals DNV - cert. #P-9538 TUV - For CHG fuel cell applications - stainless AGA/CGA - Eng. Report #125-AGA1-85 American Bureau of Shipping (ABS) - cert. # 98-C12949-X Bureau Veritas cert. #2190 1907D00H (steel only) DNV cert. # P-9085/792-22 Germanischer Lloyd cert. # 9672890HH U.S. Coast Guard cert.#16703/46 CFR 56.60 U.S.S.R. Register of Shipping cert. #93.017.260

Ferulok

EO/EO-2

Flange Adapters

JIS Adapters* K4 Adapters Pipe Fittings Pipe Plugs Straight Thread Plugs Pipe Swivel Adapters

DIN 3865 DIN 3859 SAE J518 ISO 6162-1 ISO 6162-2 ISO 6164 JIS B8363 (with some exceptions) BS 5200, ISO 8434-6** SAE J514 SAE J531 SAE J514 SAE J514

Germanischer Lloyd Lloyd's Register of Shipping DNV ABS Russian Maritime Register of Shipping China Classication Society DVGW TUV

All catalog products


Plating Carbon Steel Chromium 6 Free Zinc Stainless Steel Passivation Carbon Steel Zinc Phosphate Design All Products Test Methods Leak, Burst, Impulse, Over-Torque and Repeated Assembly Vibration

Canadian Registration
Specication ASTM B633 Type II FE/ZN8* MIL-STD-171E JIS 8610 Class 1 Grade 3 QQ-P35 Type VI ASTM A380 DOD-P-16232, Class 1

CRN: OA9941.5

*Clear/Silver Color

Specication ASME / ANSI B31.1

Comment All products meet the design factor requirements of this specication.

Specication SAE J1644 ISO 19879 NFPA T3.8.3, ISO 7257

Table U2 Conformance Standards * Some parts do not meet dimensional requirements.

Dimensions and pressures for reference only, subject to change.

U9

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical

Fluid Compatibility
The uid compatibility chart on the following page is intended as a guide only and is not to be considered as a sole selection criteria to use Parker Tube Fittings in a specic application or with a specic uid. Other factors that must be considered include, but are not limited to: Fluid temperature, ambient temperature, system pressure (both operating and peak) and applicable standards or regulations. For media not listed, please contact your Parker representative or the Tube Fittings Division.

Choosing the Tube Material and Type


Selection of tube material depends on the uid, corrosive nature of the service environment, the operating temperature range and the maximum operating pressure. The tube O.D. and wall thickness selection depends on these four parameters. A simple method of selecting the proper tube type and material is described below. Table U7 lists several common tube types with their recommended operating temperature ranges, general application, and tting compatibility. Based on the uid system parameters and media, select the appropriate tube type and material. If media and/or service environment is different from the commonly used ones listed in the general application column, please consult the Fluid Compatibility chart on the following page or contact the Tube Fittings Division. For selecting proper tube O.D. and wall thickness use the procedure given on page U15. Caution: When working with highly corrosive media, always consult the Tube Fittings Division.

Return To Index

Protective Coatings on Steel


Protective coatings such as electroplated zinc and cadmium1) and zinc phosphate are usually applied to steel ttings for extending their useful service life in corrosive environments. Cadmium and zinc corrode sacricially, protecting the steel substrate from normal atmospheric rusting due to the common presence of oxygen, moisture and acidic gases. They are, however, rapidly attacked by many uids including those containing acidic hydrogen and reactive uorine, chlorine, bromine, iodine, and nitrogen. Zinc plating will further be attacked by strong bases or water with pH > 12. Zinc reacts with glycol based re resistant uids and forms a gelatinous compound that can plug up lters and be harmful otherwise, in a system with many zinc plated tube and hose ttings. Steel ttings with zinc phosphate coating or stainless steel ttings, along with brass ttings in low pressure applications, are viable options. The other option is to run the uid through the system, without components with moving parts in it, with an auxiliary power source, to generate and ush the gelatinous compound. Then re-connect all components, change lters and charge the system with new uid. The corrosion resistance of the Chromium-6 Free standard surface treatment is a minimum of 25% improved over traditional zinc gold (hexavalent) chromate surface. Additionally, the Chromium-6 Free surface meets the EU end of life vehicle directive and ROHS compliance. Zinc phosphate coatings protect steel by covering its surface and will retard rusting as long as the inhibiting barrier is not broken. Caution: Where low toxicity and low corrosion are required, as in food or beverage applications, steel coated with any form of zinc or other protective coatings is not recommended. Notes: 1) Cadmium is not allowed by SAE and ISO stardards for general industrial and commercial use. Some military applications still require cadmium plating. These requirements are met with special (non-standard) processing at extra cost.

U10

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Fitting Material Media Acetylene Air (oil free) @ 190 F Air (oil free) @ 300 F Air (oil free) @ 400 F Alcohol, Ethyl Animal Oils (Lard Oil) Aromatic Fuel - 50% Aromatic Solvents Asphalt ASTM Oil #1 ASTM Oil #2 ASTM Oil #3 ASTM Oil #4 ATF Oil Automotive Brake Fluid Benzene Brine (Sodium Chloride) Butane Carbon Dioxide Carbon Monoxide Chlorine (Dry) Compressed Air Crude Oil Cutting Oil Diesel Fuel Ethanol Ethers Freon 11 Freon 12 Freon 22 Fuel Oil Gasoline Gas, Liquid Propane (LPG) Gas, Natural Helium Hydraulic Oil, Petroleum Base Hydraulic Oil, Water Base Hydrogen Gas Jet Fuel Kerosene Lubricating Oil SAE 10, 20, 30, 40, 50 Methanol MIL-F-8192 (JP-9) MIL-H-5606 MIL-H-6083 MIL-H-7083 MIL-H-8446 (MLO-8515) Mil-L-2104 & 2104B MIL-L-7808 Mineral Oil Nitrogen Petrolatum Petroleum Oil (<250 F) Propane R134A Sea Water Skydrol 500, Type 2 Skydrol 7000, Type 2 Soap Solutions Steam (<400 F) Stoddard Solvent Transmission Fluid (Type A) Trichloroethane Water Brass NR S S S S F ID ID NR S S S S S ID NR NR NR S S F S NR ID S S S S S S NR S S F S S ID S S S S S S S S S F S NR S S S S S S F NR NR NR F F S ID S Steel F F F F NR F ID ID NR S S S S S ID F NR S F S F F F S S NR S ID S NR S F S S S S S S S S S S S S S S S S F S S S S S S NR S S NR S S S F F 316 SS S S S S NR F ID F S S S S S S ID NR S S S S NR S S S S NR S ID NR S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S BUNA-N S S F NR NR S F F F S S S F S NR NR S S S S NR S F S S NR NR F F NR S S S S S S F S S S S S NR S S S F S F S S S S S NR S NR NR S NR S S NR S

Seal Material Ethylene Propylene Fluorocarbon S S S S F S NR S S NR F S NR S ID S NR S NR S NR S NR S NR S NR S S NR NR S S S NR S S S S S ID F S S NR S NR S NR S S NR F F NR F NR S NR NR NR S NR S NR S NR S S S NR S S NR S S NR S NR S NR S S NR NR S NR S NR S S F NR S NR S NR S NR S S S NR S NR S NR S S NR S S S NR S F S S S NR NR S NR S NR S S F

Neoprene F S F NR S F NR NR F S F NR NR F F NR S S S F F S NR F NR S NR NR S S F NR F S S S F S NR F F S NR F S F S F NR F S F F F NR F NR NR F NR F F NR F

Table U4 Fluid Compatibility Chart

Codes: S = Satisfactory NR = Not recommended

F = Fair ID = Insufcient data

Dimensions and pressures for reference only, subject to change.

U11

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Corrosion of Base Metals in Contact


The susceptibility of different base metals to corrosion while in contact, depends upon the difference between the contact potentials, or the electromotive voltages of the metals involved. The greater the potential difference is, the greater is the tendency for corrosion. The metal with the higher potential forms the anode and is corroded. In other words, the larger the separation distance in the electromotive chart between the two metals in contact, the higher the contact potential and chances for corrosion. For example, zinc and aluminum are very short distance apart in the chart; therefore potential for corrosion when these two metals are in contact is very low. On the other hand, aluminum and passivated 316 stainless steel are far apart; hence, when in contact, the potential for corrosion is very high. Aluminum, being more anodic metal, will corrode in this combination. As a general guideline, if the metals are half the length of the chart or more apart, the combination should be avoided. Also, it is not a good idea to combine an anodic metal part with thin cross section, such as thin wall tubing, with a cathodic or less anodic metal part of a heavy cross section, such as a tting. Example: A thin wall brass tube with steel tting is a better, although not ideal, combination than a thin wall steel tube with brass tting.

Electromotive or Galvanic Series for Metals

+ Anodic (least noble) corroded

- Cathodic (most noble) protected

Magnesium Magnesium alloys Zinc (Parker steel ttings are zinc plated) Berillium Aluminum 5052, 3004, 3003, 1100, 6053 Cadmium Aluminum 2117, 2017, 2024 T4 Mild steel (1018), wrought iron, free machining steel (12L14) Low alloy high strength steel, cast iron Chrome iron (active) 430 Stainless (active) 302, 303, 321, 347, 410, 416, stainless steel (active) Ni-resist 316, 317 stainless steel (active) Carpenter 20Cb-3 stainless (active) Aluminum bronze (CA 687) Hastelloy C (active) Inconnel 625 (active) Titanium (active) Lead/Tin solder Lead Tin Inconnel 600 (active) Nickel (active) 60 Ni-15 Cr (active) 80 Ni-20 Cr (active) Hastelloy B (active) Naval brass (CA 464), Yellow brass (CA 268), Brass (CA360) Red brass (CA 230), Admiralty brass (CA 443) Copper (CA 102) Maganese bronze (CA 675), Tin bronze (CA 903, 905) 410, 416 Stainless (passive) Phospher bronze (CA 521, 524) Silicon bronze (CA 651, 655) Nickel silver (CA 732, 735, 745, 752, 754, 757, 764, 770, 794) Cupro Ni 90-10 Cupro Ni 80-20 430 Stainless steel (passive) Cupro Ni 70-30 Nickel aluminum bronze (CA 630, 632) Monel 400, K500 Silver solder Nickel (passive) 60 Ni 15 Cr (passive) Inconnel 600 (passive) 80 Ni 20 Cr (passive) Chrome iron (passive) 302, 303, 304, 321, 347 stainless stainless steel (passive) 316, 317 stainless steel (passive) (Parker stainless steel ttings are passivated) Carpenter 20 Cb-3 stainless (passive), Incoloy 825 Silver Titanium (passive), Hastelloy C & C276 (passive), Inconnel 625 (passive) Graphic Zirconium Gold Platinum

Electric current ows from plus to minus

Table U5 Electromotive or Galvanic Series for Metals

Direction of attack

U12

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

O-Ring Material Selection


Standard O-rings supplied with Parker tube ttings and adapters are 90 durometer hard nitrile (Buna-N) Parker compound #N0552. These O-rings are well suited for most industrial hydraulic and pneumatic systems.They have high extrusion resistance making them suitable for very high pressure static applications. Optional high temperature uorocarbon, Parker compound #V0894, is also available for higher temperature specications. O-rings for other than normal hydraulic media or higher temperature applications can be selected from the following chart. The
Abbreviated Name NBR NBR NBR NBR Parker Compound No. N0552 N0674 N0103 N1059 SAE Hardness J515 Shore Temperature Type "A"7) Range CH2) 906) -30 to 250 F 70 -30 to 250 F 70 -65 to 225 F CH2) 90 -30 to 275 F Recommended For Petroleum base oils and uids, mineral oils, ethylene glycol base uids, silicone and di-ester base lubricants, air, water under 150F, and natural gas. Hydrogen fuel cells. Hydrogen fuel cells. Meets FDA requirements for food products. CNG Applications Phosphate ester base hydraulic uids, hot water, steam to 400F, silicone oils and greases, dilute acids and alkalis, ketones, alcohols and automotive brake uids. CO2 climate control systems. Refrigerants (freons, ammonia), high aniline point petroleum oils, mild acids, and silicate ester lubricants. Petroleum base oils and uids, some phosphate ester base uids, silicone and silicate ester base lubricants, di-ester base lubricants, acids and halogenated hydrocarbons. Dry heat (air to 400F) and high aniline point oils. Not Recommended For Phosphate ester base hydraulic uids, automotive brake uids, strong acids, ozone, freons, ketones, halogenated hydrocarbons, and methanol.

chart should be used only as a general guide. Before making nal selection for a given application, it is recommended that appropriate tests be conducted to assure compatibility with the uid, temperature, pressure and other environmental conditions. For uids not shown in the chart, please contact the Tube Fittings Division.

Polymer Nitrile-Butadiene Nitrile-Butadiene Nitrile-Butadiene Nitrile-Butadiene (Low compression set) Nitrile-Butadiene Nitrile-Butadiene Nitrile-Butadiene Nitrile-Butadiene Ethylene-Propylene Ethylene-Propylene

Color Black Black Black Black

NBR NBR NBR NBR EPDM EPDM

N0507 N0 304 N0508 N0756 E0540 E0893

Black Black Black

90 75 75 756) 80 80

-65 to 180 F -65 to 225 F -35 to 250 F -65 to 275F -65 to 275 F -65 to 275 F

Black Black CA3) Purple1) CA3)

Petroleum base oils and di-ester base lubricants.

Ethylene-Propylene Neoprene Neoprene

EPDM CR CR

E0962 C0873 C0944

Black Black Red1)

90 70 70

-65 to 275 F -45 to 250 F -45 to 250 F

Phosphate ester uids and ketones.

Fluorocarbon

FKM5) or FPM

V0747 V0884 V0894

Black Brown1) Brown1) HK4)

75 75 906)

-15 to 400 F -15 to 400 F -15 to 400 F

Silicone

Si

S0604

Rust1)

70

-65 to 450 F

Ketones, skydrol uids, amines (VDMH), anhydrous ammonia, low molecular weight esters and ethers, and hot hydrouoric or chlorosulfonic acids. Most petroleum uids, ketones, water and steam.

Table U6 O-Ring Selection

1) These Parker Chromassure color assurance O-rings are available from the Parker Hannin O-Ring Division. They help eliminate assembly errors, reduce warranty costs and liability risks, and assure safety in aftermarket business. 2) Formerly SAE Type I. 3) Formerly SAE Type II. 4) Formerly SAE Type III. 5) FKM is the ASTM designation for uorocarbon. Its ISO designation is FPM. 6) Standard compounds available from stock. 7) Use 90 durometer hard O-rings for applications with 1500 psi or higher pressures.

Dimensions and pressures for reference only, subject to change.

U13

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Tube and Fitting Material Compatibility


As a general rule, tube and tting materials should be the same. If different materials must be considered, the following chart can be used as a general guide. Since operating conditions differ with applications, this chart should be used only as a guide and not a rm recommendation. Before making a nal decision on material combination, it should be sufciently tested under appropriate conditions to assure suitability for the intended application. For additional material combinations, contact the Tube Fittings Division.
Tube Material to Fitting & Material Compatibility Seal-Lok ORFS EO / EO-2 Triple-Lok Ferulok (SAE 37 Flare Flareless Intru-Lok Flareless J1453) (SAE J514) (SAE J514) Flareless (ISO 8434-1) S SS B S SS B M S SS M B S, SS, B, M E NR (6) G NR (6) NR E NR NR -65 to 500F -55 to 260C High pressure hydraulic, air, & some specialty chemicals E NR (6) E NR (6) NR E NR NR G NR (6) NR NR (6) NR G NR NR E NR (6) NR NR (6) NR E NR NR E NR (6) E NR (6) NR E NR NR -65 to 500F -55 to 260C -65 to 500F -55 to 260C High pressure hydraulic E NR (6) NR NR NR NR NR NR NR (10) E NR (6) NR NR NR NR NR NR NR High pressure hydraulics High pressure -65 to 500F hydraulic, air, & -55 to 260C some specialty chemicals High pressure, high -425 to 1200F temperature, or -255 to 650C generally corrosive (3) media (1) High pressure, high -425 to 1200 temperature, or -255 to 650C generally corrosive (3) media (1) Low pressure, low -325 to 400F temperature, water, -200 to 205C oil & air Low pressure, low -325 to 400F temperature, water, -200 to 205C oil, air & some specialty chemicals Sour gas, marine -400 to 800F & general chemical -240 to 425C processing media Lube lines, chemcial -60 to 200F process controls -50 to 95C & air -80 to 150F Instrumentation -60 to 65C lines 0 to 140F -20 to 60C General purpose laboratory use E NR NR NR NR NR NR NR NR NR (4) E NR NR G NR NR NR NR NR NR (6) (6) (6) E (6) (6) G (6) NR (6) E NR E (6) (6) E (6) NR (6) E NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR E NR NR E

Max. Specication Construction Condition Hardness SAE J524 Seamless (ASTM A179) (8) Welded & SAE J525 Carbon Steel Fully (ASTM A178) (8) HRB 72 Drawn C-1010 Annealed Welded & SAE J356 Flash Controlled Welded & SAE J2467 Flash Carbon Steel Fully HRB 75 Controlled C-1021 Annealed Welded & SAE J2435 Drawn Welded & Carbon Steel SAE 2613 Flash High Strength Sub-critically HRB 90 Controlled Low Alloy annealed Welded & SAE J2614 (HSLA) Drawn Alloy Steel ASTM A519 Seamless 4130 St 37.4 (Carbon Steel) Stainless Steel 304 & 316 1.4571 1.4541 Stainless Steel Copper Aluminum 6061 Monel 400 Nylon Polyethylene PVC ASTM D-1248 DIN 2391 Part 2 (Metric) ASTM A213 ASTM A269 ASTM A249 ASTM A269 DIN 17458 Tab 8 (Metric) SAE J528 (ASTM B-75) (8) ASTM-B210 Seamless Seamless Welded & Drawn Seamless Fully Annealed Fully Annealed Fully Annealed Soft Annealed Temper 0 T6 Temper Seamless 0 & T4 Temper Fully Annealed Flexible & Semi-Rigid Instrument Grade Instrument & Laboratory Grade HRB 72

Tube Material

Temperature Range (7)

Application

-65 to 500F -55 to 260C

High pressure hydraulic

HRB 90

HRB 90 60 Max. Rockwell 15T HRB 56 HRB 30 HRB 70

E NR (6) G NR NR NR E NR G NR NR (2)

Seamless

(6) E

G (6) E NR

E (6) (6) NR E E G

E NR NR NR G (2), (9) G (2), (9) NR

NR NR NR G NR NR NR

E NR NR (2) E E NR NR G NR NR NR NR NR (5) (2)

ASTM-B165

Seamless Extruded Extruded Extruded Extruded & Cintered

NR (6) NR NR (6) NR E NR (6) E NR NR NR NR NR NR NR NR NR NR NR NR NR NR G G G (2) (2) (2) G G G (2) (2) (2)

NR NR NR NR NR NR NR NR NR NR

PTFE

Very low pressure, -65 to 400F high temperature, G G G NR NR NR NR NR NR NR -55 to 205C fuel, lube, chemical (2) (2) (2) & air applications

G (2), (9)

Table U7 Tube and Fitting Material Compatibility Ratings Key: NR F G E Not Recommended Fair Good Excellent Notes: 1) For highly corrosive media or service environment, contact the Tube Fittings Division. 2) Requires different assembly procedure. Contact the Tube Fittings Division. 3) Low temperature limit for stainless steel Ferulok ttings is -20F (-30C). 4) For brazing only. Grade 4130 not recommended with Parange process. 5) For use with Parange process only. Not recommended with brazing. 6) Use depends on specic application. Contact the Tube Fittings Division. 7) Applies to tube material. 8) Comparable specications to SAE. 9) With metric version of tubing. 10) Not tested with Parange. Contact the Tube Fittings Division.
Dimensions and pressures for reference only, subject to change.

Fitting Materials Code: S Steel SS Stainless Steel B Brass M Monel

U14

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Step 2: Determine Tube O.D. and Wall Thickness Using Tables U15 and U16, determine the tube O.D. and wall thickness combination that satises the following two conditions: A. Has recommended design pressure equal to or higher than maximum operating pressure. B. Provides tube I.D. equal to or greater than required ow diameter determined earlier. Design pressure values in Tables U15 and U16 are based on the severity of service rating A (design factor of 4) in Table U10, and temperature derating factor of 1 in Table U11. If more severe operating conditions are involved, the values in Tables U15 and U16 should be multiplied by appropriate derating factors from Tables U10 and U11 before determining the tube O.D. and wall thickness combination. Contact the Tube Fittings Division when in doubt. Allowable design stress levels and formula used to arrive at the design pressure values are given in the following chart. Values in Table U8 are for fully annealed tubing.
Return To Index

Determining Tube Size for Hydraulic Systems


Proper tube material, type and size for a given application and type of tting is critical for efcient and trouble free operation of the uid system. Selection of proper tubing involves choosing the right tube material, and determining the optimum tube size (O.D. and wall thickness). Proper sizing of the tube for various parts of a hydraulic system results in an optimum combination of efcient and cost effective performance. A tube that is too small causes high uid velocity, which has many detrimental effects. In suction lines, it causes cavitation which starves and damages pumps. In pressure lines, it causes high friction losses and turbulence, both resulting in high pressure drops and heat generation. High heat accelerates wear in moving parts and rapid aging of seals and hoses, all resulting in reduced component life. High heat generation also means wasted energy, and hence, low efciency. Too large of a tube increases system cost. Thus, optimum tube sizing is very critical. The following is a simple procedure for sizing the tubes. Step 1: Determine Required Flow Diameter Use Tables U13 and U14 to determine recommended ow diameter for the required ow rate and type of line. The table is based on the following recommended ow velocities: Pressure lines 25 ft./sec. or 7.62 meters/sec. Return lines 10 ft./sec. or 3.05 meters/sec. Suction lines 4 ft./sec. or 1.22 meters/sec. If you desire to use different velocities than the above, use one of the following formulae to determine the required ow diameter.
Tube I.D. (in.) = 0.64 Flow in GPM Velocity in ft./sec. Flow in liters per minute Velocity in meters/sec.

Material and Type Steel C-1010 Steel C-1021 Steel, High Strength Low Alloy (HSLA) Stainless Steel 304 & 316 Alloy Steel C-4130 Copper, K or Y Aluminum 6061-T6 Monel, 400

Allowable Design Stress fo Design Factor of 4 at 72F 12,500 PSI 15,000 PSI 18,000 PSI 18,800 PSI 18,800 PSI 6,000 PSI 10,500 PSI 17,500 PSI

Tube Specication SAE J356, J524, J525 SAE J2435, J2467 SAE J2613, J2614 ASTM A213, A249, A269 ASTM A519 SAE J528, ASTM B75 ASTM B210 ASTM B165

OR
Tube I.D. (mm) = 4.61

Table U8 Design Stress Values

Design Pressure Formula (LAMES) D2 - d2 P=S where: D 2 + d2 D = Outside diameter of tube, in d = Inside diameter of tube (D-2T), in P = Recommended design pressure, psi S = Allowable stress for design factor of 4, psi T = Tube wall thickness, in.

( )

Table U9 Design Pressure Formula

For thin wall tubes (D/T 10) the following formula may be Used: P = 2ST/D

Dimensions and pressures for reference only, subject to change.

U15

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
1. Selecting Tube Material: Table U7 indicates that carbon steel, C-1010, tubing would meet the media, operating temperature range, and maximum operating pressure (high) requirements. Sizing the Tube: From Table U13, the recommended ow diameters for various lines for 10 GPM ow rate are: 0.405 for pressure line, 0.639 for return line, and 1.012 for suction line. Now, using Tables U15 and U16, we need to nd tubes with inside diameters (I.D.) equal to or larger than the above ow diameters, and wall thicknesses appropriate for design pressures of 3500 psi minimum for the pressure line and about 500 psi for return and suction lines. Since derating factors for Severity of Service (Table U10) and Max. Operating Temperature (Table U11) are both 1, design pressure values in Tables U15 and U16 do not need to be reduced. Matching tube I.D.s and design pressures in Tables U15 and U16 for above conditions, we nd: A) For the pressure line, we would choose 5/8 O.D. x .083 wall tubing. The .095 and .109 wall tubes would also be satisfactory if .083 wall is not readily available. B) For the return line, either 3/4 x .035 or 3/4 x .049 would meet the requirements. If Ferulok ttings are being used, we will need to go to 3/4 x .065 because .065 is the smallest wall thickness recommended for 3/4 O.D. tubing used with Ferulok ttings in Table U14. This reduces the ow diameter about 3% below the recommended value, but is still in the acceptable range. The alternative is to go to 7/8 O.D. x .072 wall tubing, which is way too large.
Steel Alloy Steel St. Steel Copper Monel SAE O-ring Face Seal Seal-Lok 1) .020 - .083 .020 - .095 .020 - .109 .028 - .148 .035 - .134 .035 - .148 .035 - .188 .049 - .220 .049 - .250 .065 - .220

Severity of Service A (Normal) B (Severe) C (Hazardous)

Description Moderate mechanical and hydraulic shocks. Severe hydraulic shocks and mechanical strain. Hazardous application with severe service conditions.

Design Factor 4.00 6.00 8.00

Derating Factor 1.00 0.67 0.50

Return To Index

2.

Table U10 Severity of Service Design and Derating Factors

The design factor is generally applied to ultimate strength of material (or burst pressure of tubing) to provide a measure of safety against the unknowns in material and operating conditions. The derating factors listed here should be applied directly to the design pressure values in Tables U15 and U16 to arrive at maximum recommended working pressures (i.e., multiply values in Tables U15 and U16 by these derating factors). Besides severity of service, high operating temperature also reduces allowable working pressure of the tubing. Temperature derating factors for various tube materials are given in Table U11. Where applicable, derating factors for severity of service and temperature should be applied to the design pressure values in Tables U15 and U16 to arrive at the maximum recommended working pressure. Example: Combined derating factor for 316SS tubing for B (severe) service and 500 F. operation is .67 x .9 = .603

Tube Selection Example:


Steel Maximum Operating C-1010 Temperature and (degrees F) C-4130 100 1.00 150 1.00 200 1.00 250 1.00 300 1.00 350 0.99 400 0.98 500 0.96 600 700 800 900 1000 1100 1200 Stainless Steel 304 1.00 0.91 0.84 0.79 0.75 0.72 0.69 0.65 0.61 0.59 0.57 0.54 0.52 0.47 0.32 316 1.00 1.00 1.00 1.00 1.00 0.99 0.97 0.90 0.85 0.82 0.80 0.78 0.77 0.62 0.37 Copper 1.00 0.85 0.80 0.80 0.78 0.67 0.50 Aluminum Monel 6061-T6 Type 400 1.00 1.00 1.00 0.97 1.00 0.94 0.94 0.91 0.80 0.88 0.60 0.86 0.43 0.85 0.84 0.84 0.84 0.83

Table U11 Temperature Derating Factors* for Tubes

* The derating factors are based on allowable design stress values at various temperatures per ASME B31.1 code for pressure piping (1986). To select tube material and tube sizes for pressure, return and suction lines for a hydraulic power unit with the following operating parameters known: Type of uid: Petroleum base hydraulic uid Operating temperature range: -20F to +140F. Maximum operating pressure: 3500 psi Maximum ow rate through each line: 10 GPM Severity of service: A (normal)

Steel St. Steel Tube Material Copper Size Aluminum SAE O.D. O.D. Dash 37 Flare (in.) (mm) Number Triple-Lok 1/8 4 -2 .010 - .035 3/16 6 -3 .010 - .035 1/4 8 -4 .020 - .065 5/16 10 -5 .020 - .065 3/8 12 -6 .020 - .065 1/2 14 -8 .028 - .083 5/8 15 -10 .035 - .095 3/4 16 -12 .035 - .109 7/8 18 -14 .035 - .109 1 20 -16 .035 - .120 1 1/4 22 -20 .049 - .120 1 1/2 25 -24 .049 - .120 2 28 -32 .058 - .134 30 35 38 42

Steel St. Steel Monel SAE Flareless Ferulok .010 - .035 .020 - .049 .028 - .065 .028 - .065 .035 - .095 .049 - .120 .058 - .120 .065 - .120 .072 - .120 .083 - .148 .095 - .188 .095 - .220 .095 - .220

Copper Aluminum Steel Plastics St. Steel Metric Intru-Lok Flareless .012 - .028 0.5 - 1 .012 - .035 1 - 2 .020 - .049 1 - 2.5 .020 - .065 1 - 3 .028 - .065 1.5 - 3.5 .035 - .083 1.5 - 4 .035 - .083 1.5 - 4 .035 - .095 2 - 4 .049 - .095 2 - 4 .049 - .120 2.5 - 4 2.5 - 4 2.5 - 4.5 2.5 - 4.5 2.5 - 5 3-5 3-6 3.5 - 7

1) Brazing to attach sleeve can be used for all wall thicknesses. For anging tool availability, see page S26. Table U12 Recommended Min./Max Tube Wall Thickness for Common Fittings

C) For the suction line, we can use any one of the following tubes: 1-1/4 O.D. x .049 to .083 wall tube for Triple-Lok or Seal-Lok ttings and 1-1/4 O.D. x .095 wall tube for Ferulok ttings. One nal consideration in choosing the right wall thickness for tubing is bending. If bending without the use of a mandrel is desired, then wall thickness of less than 7% of tube O.D. should not be used.

Dimensions and pressures for reference only, subject to change.

U16

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Recommended Flow Diameters In Inches


Recommended Flow Diameter in Inches Pressure Return Suction Lines Lines Lines 0.064 0.101 0.160 0.091 0.143 0.226 0.111 0.175 0.277 0.128 0.202 0.320 0.143 0.226 0.358 0.157 0.247 0.392 0.169 0.267 0.423 0.181 0.286 0.453 0.202 0.319 0.506 0.222 0.350 0.554 0.239 0.378 0.599 0.256 0.404 0.640 0.272 0.429 0.679 0.286 0.452 0.716 0.300 0.474 0.750 0.314 0.495 0.784 0.326 0.515 0.816 0.339 0.534 0.847 0.351 0.553 0.876 0.362 0.571 0.905 0.373 0.589 0.933 0.384 0.606 0.960 0.395 0.623 0.986 0.405 0.639 1.012 0.425 0.670 1.061 0.443 0.700 1.109 0.462 0.728 1.154 0.479 0.756 1.197 0.496 0.782 1.239 0.512 0.808 1.280 0.528 0.833 1.319 0.543 0.857 1.358 0.558 0.880 1.395 0.572 0.903 1.431 0.600 0.947 1.501 0.627 0.990 1.568 0.653 1.030 1.632 0.677 1.069 1.693 0.701 1.106 1.753 0.724 1.143 1.810 0.746 1.178 1.866 0.768 1.212 1.920 0.789 1.245 1.973 0.810 1.278 2.024 0.830 1.309 2.074 0.849 1.340 2.123 0.868 1.370 2.170 0.887 1.399 2.217 0.905 1.428 2.263 0.949 1.498 2.373 0.991 1.565 2.479 Recommended Flow Diameter in Inches Pressure Return Suction Lines Lines Lines 1.032 1.629 2.580 1.071 1.690 2.677 1.109 1.749 2.771 1.145 1.807 2.862 1.180 1.862 2.950 1.214 1.916 3.036 1.248 1.969 3.119 1.280 2.020 3.200 1.342 2.119 3.356 1.402 2.213 3.505 1.459 2.303 3.649 1.515 2.390 3.786 1.568 2.474 3.919 1.619 2.555 4.048 1.669 2.634 4.172 1.717 2.710 4.293 1.764 2.784 4.411 1.810 2.857 4.525

Maximum Flow Rate GPM 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00 34.00 36.00 38.00 40.00 42.00 44.00 46.00 48.00 50.00 55.00 60.00

Maximum Flow Rate GPM 65.00 70.00 75.00 80.00 85.00 90.00 95.00 100.00 110.00 120.00 130.00 140.00 150.00 160.00 170.00 180.00 190.00 200.00

Table U13 Recommended Flow Diameters, in Inches

Dimensions and pressures for reference only, subject to change.

U17

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Recommended Flow Diameters In Millimeters


Recommended Flow Diameter in Millimeters Pressure Return Suction Lines Lines Lines 1.670 2.640 4.180 2.362 3.734 5.911 2.893 4.573 7.240 3.340 5.280 8.360 3.734 5.903 9.347 4.091 6.467 10.239 4.418 6.985 11.059 4.723 7.467 11.823 5.010 7.920 12.540 5.281 8.348 13.218 5.785 9.145 14.480 6.249 9.878 15.640 6.680 10.560 16.720 7.085 11.201 17.734 7.468 11.806 18.694 7.833 12.383 19.606 8.181 12.933 20.478 8.515 13.461 21.314 8.837 13.970 22.118 9.147 14.460 22.895 9.447 14.934 23.646 9.738 15.394 24.373 10.020 15.840 25.080 10.295 16.274 25.767 10.562 16.697 26.437 11.203 17.710 28.040 11.809 18.668 29.557 12.385 19.579 31.000 12.936 20.449 32.378 13.464 21.284 33.700 13.972 22.088 34.972 14.463 22.863 36.200 14.937 23.613 37.387 15.397 24.340 38.538 15.843 25.045 39.655 16.277 25.732 40.742 16.700 26.400 41.800 17.515 27.689 43.840 18.294 28.920 45.790 19.041 30.101 47.659 19.760 31.237 49.458 20.453 32.333 51.194 21.124 33.394 52.873 21.774 34.421 54.501 22.405 35.419 56.081 23.019 36.390 57.617 23.617 37.335 59.114 24.770 39.158 61.999 25.872 40.899 64.756 26.928 42.569 67.400 27.944 44.176 69.945 Recommended Flow Diameter in Millimeters Pressure Suction Return Lines Lines Lines 28.925 45.726 72.400 29.874 47.226 74.774 30.793 48.679 77.075 31.686 50.090 79.310 32.554 51.463 81.483 33.400 52.800 83.600 35.426 56.003 88.671 37.342 59.032 93.468 39.165 61.913 98.030 40.906 64.667 102.389 42.577 67.307 106.570 44.184 69.848 110.592 45.735 72.299 114.474 47.235 74.670 118.228

Maximum Flow Rate LPM* 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 45 50 55 60 65 70 75 80 85 90 95 100 110 120 130 140 150 160 170 180 190 200 220 240 260 280

Maximum Flow Rate LPM* 300 320 340 360 380 400 450 500 550 600 650 700 750 800

Table U14 Recommended Flow Diameters, in Millimeters * LPM = Liters Per Minute

Dimensions and pressures for reference only, subject to change.

U18

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Inch Tube Pressure Ratings


Inch Tubes* Design Pressure (4:1 Design Factor), PSI Stainless Steel Steel 304 & 316, Steel 4130, HSLA Copper 1010 1021 2150 2600 3250 1050 4600 5500 6900 2200 6650 8000 10000 3200 8450 10150 12700 4050 1400 1700 2100 650 2950 3550 4450 1400 4250 5100 6400 2050 5450 6550 8200 2600 7850 9400 11800 3750 2150 2600 3250 1050 3100 3700 4650 1500 3950 4750 5950 1900 5750 6900 8650 2750 6900 8300 10400 3300 7800 9350 11750 3750 9950 11950 15000 4800 1700 2050 2550 800 2450 2950 3650 1150 3100 3700 4650 1500 4500 5400 6750 2150 5400 6500 8150 2600 6150 7400 9250 2950 6850 8200 10350 3300 8000 9600 12050 3850 9150 11000 13800 4400 1400 1700 2100 650 2000 2400 3000 950 2550 3050 3850 1200 3650 4400 5550 1750 4450 5350 6650 2100 5000 6000 7550 2400 5600 6700 8450 2700 6550 7900 9900 3150 7600 9100 11450 3650 8750 10500 13200 4200 1500 1800 2200 700 1850 2200 2800 900 2700 3250 4050 1300 3250 3900 4850 1550 3650 4400 5500 1750 4100 4900 6150 1950 4800 5750 7200 2300 5550 6650 8350 2650 6450 7750 9750 3100 7200 8650 10800 3450 8050 9650 12150 3850 8950 10750 13450 4300 11050 13250 16600 5300 Inch Tubes* Design Pressure (4:1 Design Factor), PSI Stainless Steel Steel 304 & 316, Steel 4130, HSLA Copper 1010 1021 1150 1400 1750 550 1500 1800 2200 700 2100 2500 3200 1000 2550 3050 3800 1200 2850 3400 4300 1350 3200 3850 4800 1550 3750 4500 5650 1800 4350 5200 6550 2100 5050 6050 7600 2450 5600 6700 8450 2700 6350 7600 9550 3050 1200 1450 1850 600 1750 2100 2600 850 2100 2500 3150 1000 2350 2800 3550 1150 2650 3200 3950 1250 3050 3650 4600 1450 3550 4250 5350 1700 4150 5000 6200 2000 4600 5500 6900 2200 5200 6250 7800 2500 5800 7000 8700 2800 7500 9000 11300 3600 1050 1250 1550 500 1500 1800 2200 700 1750 2100 2650 850 2000 2400 3000 950 2200 2650 3350 1050 2600 3100 3900 1250 3000 3600 4500 1450 3500 4200 5250 1650 3900 4700 5850 1850 4400 5300 6600 2100 4900 5900 7350 2350 900 1100 1350 450 1300 1550 1950 600 1550 1850 2300 750 1750 2100 2600 850 1950 2350 2900 950 2250 2700 3400 1100 2600 3100 3900 1250 3000 3600 4550 1450 3350 4000 5050 1600 3800 4550 5700 1800 4200 5050 6350 2000 4450 5350 6700 2150 5500 6600 8250 2650 6550 7850 9800 3150

Tube O.D. (in.) 0.125 0.125 0.125 0.125 0.188 0.188 0.188 0.188 0.188 0.250 0.250 0.250 0.250 0.250 0.250 0.250 0.313 0.313 0.313 0.313 0.313 0.313 0.313 0.313 0.313 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500

Wall Thick. (in.) 0.010 0.020 0.028 0.035 0.010 0.020 0.028 0.035 0.049 0.020 0.028 0.035 0.049 0.058 0.065 0.083 0.020 0.028 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.020 0.028 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.028 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.188

Tube I.D. (in.) 0.105 0.085 0.069 0.055 0.168 0.148 0.132 0.118 0.090 0.210 0.194 0.180 0.152 0.134 0.120 0.084 0.273 0.257 0.243 0.215 0.197 0.183 0.169 0.147 0.123 0.335 0.319 0.305 0.277 0.259 0.245 0.231 0.209 0.185 0.157 0.444 0.430 0.402 0.384 0.370 0.356 0.334 0.310 0.282 0.260 0.232 0.204 0.124

Tube O.D. (in.) 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.625 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.875 0.875 0.875 0.875 0.875 0.875 0.875 0.875 0.875 0.875 0.875 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000

Wall Thick. (in.) 0.028 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.188 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.035 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.156 0.188 0.220

Tube I.D. (in.) 0.569 0.555 0.527 0.509 0.495 0.481 0.459 0.435 0.407 0.385 0.357 0.680 0.652 0.634 0.620 0.606 0.584 0.560 0.532 0.510 0.482 0.454 0.374 0.805 0.777 0.759 0.745 0.731 0.709 0.685 0.657 0.635 0.607 0.579 0.930 0.902 0.884 0.870 0.856 0.834 0.810 0.782 0.760 0.732 0.704 0.688 0.624 0.560

* See Table U8 for tube specications. Table U15 Inch Tube Pressure Ratings

Dimensions and pressures for reference only, subject to change.

U19

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Inch Tube Pressure Ratings (contd.)


Inch Tubes* Design Pressure (4:1 Design Factor), PSI Tube O.D. (in.) 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 Wall Thick. (in.) 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.156 0.188 0.22 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.156 0.188 0.220 0.250 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.148 0.156 0.188 0.220 0.250 0.281 Tube I.D. (in.) 1.152 1.134 1.120 1.106 1.084 1.060 1.032 1.010 0.982 0.954 0.938 0.874 0.810 1.370 1.356 1.334 1.310 1.282 1.260 1.232 1.204 1.188 1.124 1.060 1.000 1.870 1.856 1.834 1.810 1.782 1.760 1.732 1.704 1.688 1.624 1.560 1.500 1.438 Stainless Steel 304 & 316, 4130, HSLA Copper 1550 500 1850 600 2050 650 2300 750 2650 850 3050 1000 3550 1150 3950 1250 4450 1400 4950 1600 5250 1700 6450 2050 7700 2450 1700 550 1900 600 2200 700 2550 800 2950 950 3250 1050 3650 1150 4050 1300 4300 1350 5300 1700 6300 2000 7250 2300 1250 400 1400 450 1600 500 1850 600 2150 700 2400 750 2700 850 3000 950 3150 1000 3850 1250 4600 1450 5250 1700 6000 1900

Steel 1010 1000 1200 1350 1500 1750 2050 2350 2650 2950 3300 3500 4300 5100 1150 1250 1450 1700 1950 2150 2450 2700 2850 3500 4150 4800 850 950 1100 1250 1450 1600 1800 2000 2100 2550 3050 3500 4000

Steel 1021 1200 1450 1600 1800 2100 2450 2800 3200 3550 3950 4200 5150 6100 1400 1500 1750 2050 2350 2600 2950 3250 3400 4200 5000 5750 1000 1150 1300 1500 1750 1900 2150 2400 2500 3050 3650 4200 4800

* See Table U8 for tube specications. Table U15 Inch Tube Pressure Ratings, contd.

Dimensions and pressures for reference only, subject to change.

U20

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index
Tube O.D. (mm) 25 25 25 28 28 28 28 30 30 30 30 30 35 35 35 35 38 38 38 38 38 38 42 42 42 50 50 65 Wall Thick. (mm) 4.0 4.5 5.0 1.5 2.0 2.5 3.0 2.0 2.5 3.0 4.0 5.0 2.0 2.5 3.0 4.0 2.5 3.0 4.0 5.0 6.0 7.0 2.0 3.0 4.0 6.0 9.0 8.0 Metric Tubes Static Design Pressure (Bar) Steel Stainless Tube I.D. Low-Carbon Steel St. 37-4 (mm) 1.4571 17.0 394 16.0 437 15.0 478 25.0 151 158 24.0 201 210 23.0 252 22.0 302 26.0 188 25.0 235 245 24.0 282 294 22.0 336 392 20.0 409 31.0 161 168 30.0 201 29.0 242 27.0 322 33.0 186 32.0 223 30.0 297 309 28.0 332 26.0 390 24.0 446 38.0 134 140 36.0 201 210 34.0 269 38.0 338 32.0 437 49.0 347

Metric Tube Pressure Ratings


Tube O.D. (mm) 4 4 4 5 6 6 6 6 6 8 8 8 8 10 10 10 10 10 12 12 12 12 12 12 14 14 14 14 14 14 15 15 15 15 16 16 16 16 18 18 18 18 18 20 20 20 20 20 20 22 22 22 22 25 25 25 Wall Thick. (mm) 0.5 0.75 1.0 1.0 0.75 1.0 1.5 2.0 2.25 1.0 1.5 2.0 2.5 1.0 1.5 2.0 2.5 3.0 1.0 1.5 2.0 2.5 3.0 3.5 1.5 2.0 2.5 3.0 3.5 4.0 1.0 1.5 2.0 3.0 1.5 2.0 2.5 3.0 1.0 1.5 2.0 2.5 3.0 1.5 2.0 2.5 3.0 3.5 4.0 1.5 2.0 2.5 3.0 2.0 2.5 3.0 Metric Tubes Static Design Pressure (Bar) Steel Stainless Tube I.D. Low-Carbon Steel St. 37-4 (mm) 1.4571 3.0 313 2.5 409 2.0 522 600 3.0 432 4.5 333 4.0 389 426 3.0 549 600 2.0 692 1.5 757 6.0 333 368 5.0 431 472 4.0 549 3.0 658 8.0 282 294 7.0 373 389 6.0 478 498 5.0 576 4.0 666 10.0 235 245 9.0 353 368 8.0 409 426 7.0 495 6.0 576 5.0 651 11.0 302 315 10.0 357 420 9.0 434 452 8.0 507 7.0 576 6.0 641 13.0 188 196 12.0 282 294 11.0 336 392 9.0 478 13.0 264 276 12.0 353 368 11.0 386 403 10.0 452 472 16.0 157 15.0 235 245 14.0 313 327 13.0 392 12.0 409 17.0 212 16.0 282 294 15.0 353 368 14.0 373 389 13.0 426 12.0 478 19.0 192 200 18.0 256 267 17.0 320 16.0 343 21.0 226 20.0 282 294 19.0 338 353

Table U16 Metric Tube Pressure Ratings

Dimensions and pressures for reference only, subject to change.

U21

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Tube Fittings Pressure Drop


In hydraulic systems, pressure drop represents loss of energy and therefore should be kept to a minimum. Pressure loss in straight tubing and hose is mainly caused by the frictional resistance of the walls, while in ttings it is mainly caused by changes in the magnitude or direction of the uid velocity. Mathematical analysis of pressure drop, even though possible, may not be exact because of the interrelationship of factors such as uid density, velocity, ow area and frictional co-efcients. The following pressure drop charts were derived from actual test data and may be used as a guide for determining pressure drops at various ow rates through ttings for uid indicated. To determine pressure drop for a given ow, trace a vertical line up from the ow axis to the desired size line then trace a horizontal line from this intersection over to the pressure drop axis. Example: A size 8 CTX, with oil, similar to the test uid, owing through it at 4 gallons per minute, would cause a pressure drop of approximately 2.3 psi. Conversions will have to be made for uids which are not similar to test uid. The Tube Fittings part numbers are listed below the Pressure Drop Chart to which they apply.

Examples:

Fig. U2 Pressure Drop Chart for 90 Fittings or Branch Path Through a Tee or Cross Fitting (Triple-Lok)

Pressure Drops for Other Fitting: *These pressure drop curves were established with Triple-Lok ttings. The pressure drop values can be adjusted for other ttings of the same size by multiplying the value from the chart by the ratio of Triple-Lok ow diameter to that of the other tting, raised to the 4th power. Example: Find pressure drop for 6C5L at 5 gallons per minute ow rate: From the chart, the pressure drop for 6C5X is 10 psi. Also, the ratio of 6C5X to 6C5L ow diameters is 0.297/0.264, or 1.125. Therefore, the pressure drop for Seal-Lok = 10 x (1.125)4 = 16 psi. Pressure Drops for Other Fluids: Pressure drop through a tting is mainly caused by change in direction and velocity of the uid. Therefore, it is directly proportional to the specic gravity of the uid. The drop due to friction, which is dependent on the viscosity of the uid, is so small in this case that it can be ignored. Thus, the pressure drop with a different uid can be calculated by multiplying the value from the graph above by the ratio of specic gravity of the two uids, or: New Drop = Value from the graph x Specic Gravity of New Fluid Specic Gravity of Test Fluid (0.873)
Dimensions and pressures for reference only, subject to change.

U22

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Examples:
Return To Index

Fig. U3 Pressure Drop Chart for Straight Fittings and Run Legs of Tees and Crosses (Triple-Lok)

Example:

Fig. U4 Pressure Drop Chart for 45 Elbow Fittings (Triple-Lok)

Dimensions and pressures for reference only, subject to change.

U23

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Fitting and Adapter Pressure Ratings


Pressure Ratings
Pressure ratings shown on the product pages of this catalog are for dynamic systems. A vast majority of systems where our ttings are used fall in this category. However, there are applications, such as hydraulic jacks, where the system pressure is essentially static once it is pressurized. For this type of an application the ttings can be used at higher pressures. The dynamic and static systems can be dened as follows: Dynamic: A system in which the operating pressure uctuates, in accordance with load, up to a maximum pressure limited by the relief valve. In addition, the system may also experience shocks, vibration and temperature excursions. Example: A backhoe. Static: A system, once pressurized, is essentially free of pressure uctuations, shock, vibration and temperature excursions, with such pressurizations not exceeding 30,000 in the life of the system. Example: A hydraulic jack. The dynamic pressure ratings are based on a minimum design factor of 4. In other words, the tting is capable of holding a pressure equal to 4 times the rated pressure before leakage or failure. For static applications, the design factor can be 3. Hence, the static rating can be determined by multiplying the dynamic rating by 1.33. Static pressure rating = 1.33 x Dynamic pressure rating Example: Static pressure rating for a tting rated at 6000 psi = 1.33 x 6000 = 8000 psi

Higher (dynamic) Ratings


Some parts are capable of performing at higher pressures than those shown on the product pages. For information on higher ratings, contact Tube Fittings Division.

Dimensions and pressures for reference only, subject to change.

U24

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

ISO 6149-1 Metric Straight Thread O-Ring Port


(SAE 2244-1/DIN 3852, Part 3) Metric ISO 261, M Thread

Thread Size d11) M8 X 1 M10 X 1 M12 X 1.5 M14 X 1.56) M16 X 1.5 M18 X 1.5 M22 X 1.5 M27 X 2 M30 X 2 M33 X 2 M42 X 2 M48 X 2 M60 X 2

Large d22) min 17 20 23 25 28 30 33 40 44 49 58 63 74

Small d23) min 14 16 19 21 24 26 29 34 38 43 52 57 67

d34) ref. 3 4.5 6 7.5 9 11 14 18 21 23 30 36 44

d4

d5 + 0.1 0

d6 +0.5 0 14 16 19 21 24 26 29 34 38 43 52 57 67

L1 +0.4 0 1.6 1.6 2.4 2.4 2.4 2.4 2.4 3.1 3.1 3.1 3.1 3.1 3.1

L25) min 11.5 11.5 14 14 15.5 17 18 22 22 22 22.5 25 27.5

L3 max 1 1 1.5 1.5 1.5 2 2 2 2 2.5 2.5 2.5 2.5

L4 min full thread 10 10 11.5 11.5 13 14.5 15.5 19 19 19 19.5 22 24.5

Z 1 12 12 15 15 15 15 15 15 15 15 15 15 15 Parker O-ring Size8) M8 ISO O-ring M10 ISO O-ring M12 ISO O-ring M14 ISO O-ring M16 ISO O-ring M18 ISO O-ring M22 ISO O-ring M27 ISO O-ring M30 ISO O-ring M33 ISO O-ring M42 ISO O-ring M48 ISO O-ring M60 ISO O-ring

12.5 14.5 17.5 19.5 22.5 24.5 27.5 32.5 36.5 41.5 50.5 55.5 65.5

9.1 11.1 13.8 15.8 17.8 19.8 23.8 29.4 32.4 35.4 44.4 50.4 62.4

FOR CARTRIDGE VALVE CAVITIES ONLY (SEE ISO 7789) M20X1.57) 32 27 25.5 21.8 27 2.4 2 14.5 15 M20 ISO O-ring

Table U17 Port Detail ISO 6149-1

1) Per ISO 261 tolerance class 6H. Tap drill per ISO 2306 class 6H. 2) Spotface diameter with the optional identication ridge. 3) Spotface diameter without identication ridge. Port to be identied by marking metric next to it or ISO 6149-1 Metric on component name plate. 4) Reference only. Connecting hole application may require a different size. 5) Tap drill depths given require use of a bottoming tap to produce the specied full thread lengths. Where standard taps are used, increase tap drill depths accordingly. 6) Preferred for diagnostic port applications. 7) For cartridge valve cavity applications only. 8) 90 durometer nitrile is standard for hydraulic applications. NOTE: For port tapping tools, see pages S34 and S35. See page T6 for assembly torques.

Dimensions and pressures for reference only, subject to change.

U25

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

SAE J1926-1 SAE Straight Thread O-ring Port (ISO 11926-1)


(Conforms to MS16142. Does NOT conform to MS33649(8).) UN/UNF Threads

Nominal Tube OD1) Nom SAE Dash Size -2 -3 -4 -5 -6 -8 -10 -12 -14 -16 -20 -24 -32
2)

Thread Size ANSI B1.1 (ISO 263) (in) 5/16-24 UNF-2B 3/8-24 UNF-2B 7/16-20 UNF-2B 1/2-20 UNF-2B 9/16-18 UNF-2B 3/4-16 UNF-2B 7/8-14 UNF-2B 1 1/16-12 UN-2B 1 3/16-12 UN-2B 1 5/16-12 UN-2B 1 5/8-12 UN-2B 1 7/8-12 UN-2B 2 1/2-12 UN-2B

d2 dia.3) d3 dia. d4 dia. d5 dia.4) min. (mm) 17 19 21 23 25 30 34 41 45 49 58 65 88 (mm) 1.6 3.2 4.4 6.0 7.5 10.0 12.5 16.0 18.0 21.0 27.0 33.0 45.0 min. (mm) 11 13 15 16 18 22 26 32 35 38 48 54 70 +0.13 -0.00 (mm) 9.1 10.7 12.4 14.0 15.6 20.6 23.9 29.2 32.3 35.5 43.5 49.8 65.7

L1

L25)

L33), 6)

L4 Full Thread min. (mm) 10.0 10.0 11.5 11.5 12.7 14.3 16.7 19.0 19.0 19.0 19.0 19.0 19.0

Z 1 deg 12 12 12 12 12 15 15 15 15 15 15 15 15 Parker O-ring Size7) 3-902 3-903 3-904 3-905 3-906 3-908 3-910 3-912 3-914 3-916 3-920 3-924 3-932

Inch (in) 1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8 1 1 1/4 1 1/2 2

Metric (mm) 4 6 8 10 12 14, 15, 16 18, 20 22 25, 28 30, 32, 35 38, 42 50

+0.4 min. max. -0.0 (mm) (mm) (mm) 1.9 1.9 2.4 2.4 2.5 2.5 2.5 3.3 3.3 3.3 3.3 3.3 3.3 12.0 12.0 14.0 14.0 15.5 17.5 20.0 23.0 23.0 23.0 23.0 23.0 23.0 1.6 1.6 1.6 1.6 1.6 2.4 2.4 2.4 2.4 3.2 3.2 3.2 3.2

Table U18 Port Detail SAE J1926-1 (ISO 11926-1)

1) Nominal tube OD is shown for the standard inch sizes and the conversion to equivalent millimeter sizes. Figures are for reference only, as any boss can be used for a tubing size depending upon other design criteria. 2) See SAE J846 for more information. 0.2 3) If face of boss is on a machined surface, dimensions d2 and L3 need not apply as long as corner radius R0.1 is maintained. 4) Diameter d5 shall be concentric with thread pitch diameter within 0.004 in (0.1mm) FIM, and shall be free from longitudinal and spiral tool marks. Annular tool marks up to 100 in (2.5m) max shall be permissible. 5) Tap drill depths given require use of bottoming taps to produce the specied full thread lengths. Where standard taps are used, the tap drill depths must be increased accordingly. 6) Maximum recommended spotface depth to permit sufcient wrench grip for proper tightening of the tting or locknut. 7) 90 durometer nitrile is standard for hydraulic applications. 8) See page U27. NOTE: For port tapping tools, see page S34. For assembly torques see page T5.
Dimensions and pressures for reference only, subject to change.

U26

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

SAE Straight Thread Connector Use in MS33649


SAE straight thread connectors, such as Parker F5OX, need a special hex chamfer of 35 to a controlled diameter to function properly in MS33649 port. In the past, when MS33649 was more popular, Parker ttings were made with this chamfer. However, this port has been superseded by SAE J1926-1 in industrial applications for over 50 years. Since J1926-1 is a superior design, Parker, along with other manufacturers, discourages the use of MS33649 port in nonaircraft applications. In fact, a chamfer modication requirement for MS33649 will not be in the next printing of the SAE J514 specication, again to discourage the use of this port. If you must use this port, you have to request ttings with this special chamfer requirement, which makes them special and more expensive.

U27

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

ISO 6162 Four-Bolt Flange Connection (Includes SAE J518)

Nominal Flange Size D3 Type I (in) (mm) Thread

2.5 to 31.5 MPa Series1) (SAE Code 61) Clamping Screws Screw Holes Type II2) (SAE J518) C max. t1 Min. depth Thread (UNC) t1 Min. depth 0.25 Flange Half and Bolt Pattern

O-Rings3) Parker J min. W 0.25 Y Ref. L5 L6 ISO 3601-1 ID x Section O-Ring Size

1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 5

13 19 25 32 38 51 64 76 89 102 127

M8 x 1.25 M10 x 1.5 M10 x 1.5 M10 x 1.5 M12 x 1.75 M12 x 1.75 M12 x 1.75 M16 x 2 M16 x 2 M16 x 2 M16 x 2

12.5 16.5 14.5 16.5 19.5 19.5 21.5 28.5 28.5 25.5 27.5

5/16 - 18 3/8 - 16 3/8 - 16 7/16 - 14 1/2 - 13 1/2 - 13 1/2 - 13 5/8 - 11 5/8 - 11 5/8 - 11 5/8 - 11

24 22 22 28 27 27 30 30 33 30 33

38.1 47.6 52.4 58.7 69.9 77.8 88.9 106.4 120.7 130.2 152.4

54.9 65.8 70.6 80.3 94.5 103.1 115.8 136.7 153.9 163.6 182.6

53.1 64.3 69.1 78.5 93.0 100.1 112.8 133.4 150.9 160.3 185.7

17.5 22.3 26.2 30.2 35.7 42.9 50.8 61.9 69.9 77.8 92.1

46 52 59 73 83 97 109 131 140 152 181

13 14 16 144) 16 16 19 22 22 25 28

19 22 22 24 25 26 38 41 28 35 41

19 x 3.55 25 x 3.55 32.5 x 3.55 37.5 x 3.55 47.5 x 3.55 56 x 3.55 69 x 3.55 85 x 3.55 97.5 x 3.55 112 x 3.55 136 x 3.55

2-210 2-214 2-219 2-222 2-225 2-228 2-232 2-237 2-241 2-245 2-253

Nominal Flange Size D3 Type I (in) (mm) Thread

40 MPa Series1) (SAE Code 62) Clamping Screws Screw Holes Type II2) (SAE J518) C max. t1 Min. depth Thread (UNC) t1 Min. depth 0.25 Flange Half and Bolt Pattern

O-Rings3) Parker J min. W 0.25 Y Ref. L5 L6 ISO 3601-1 ID x Section O-Ring Size

1/2 3/4 1 1 1/4 1 1/2 2

13 19 25 32 38 51

M8 x 1.25 M10 x 1.5 M12 x 1.75 M12 x 1.75 M16 x 2 M20 x 2.5

14.5 16.5 21.5 18.5 25.5 33.5

5/16 - 18 3/8 - 16 7/16 - 14 1/2 - 13 5/8 - 11 3/4 - 10

21 24 27 25 35 38

40.5 50.8 57.2 66.6 79.3 96.8

57.2 55.6 72.1 70.6 81.8 80.3 96.0 94.5 114.3 111.3 134.9 131.8

18.2 23.8 27.8 31.8 36.5 44.5

48 60 70 78 95 114

16 19 24 27 30 37

22 28 33 38 43 52

19 x 3.55 25 x 3.55 32.5 x 3.55 37.5 x 3.55 47.5 x 3.55 56 x 3.55

2-210 2-214 2-219 2-222 2-225 2-228

Table U19 Port Detail ISO 6162

1) 1 MPa = 10 bar = 145 PSI. 2) Not for new design. 3) 90 durometer nitrile is standard for hydraulic applications. 4) 16 mm is also acceptable. NOTE: For assembly procedure and torques, see page T8.
Dimensions and pressures for reference only, subject to change.

U28

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

ISO 1179-11) Flat Face Port with British Standard Pipe, Parallel (BSPP) Threads
(DIN 3852, Part 2) ISO 228-1 G Threads

D4 (mm) Thread Size (ISO 228-1) G 1/8-28 G 1/4-19 G 3/8 19 G 1/2-14 G 3/4-14 G 1-11 G 1 1/4-11 G 1 1/2-11 G 2-11 D3 (mm) 9.9 13.3 16.8 21.1 26.6 33.5 42.2 48.1 59.9 Narrow Types B&E 15 20 23 28 33 41 51 56 69 Wide Types G&H 17.2 20.7 24.5 34.0 40.0 46.1 54.0 60.5 73.3 L1 max. (mm) 1.0 1.5 2.0 2.5 2.5 2.5 2.5 2.5 3.0 L2 min. (mm) 8.5 12.5 12.5 14.5 16.5 18.5 20.5 22.5 26.0

EOlastic Seal (Type E)

O-Ring and Retaining Ring (Types G & H)3 Parker O-Ring I.D. x Section Retaining Ring O-Ring Size2 (mm) Part Number 5-585 7.98 x 1.88 1/8 Retaining Ring 2-111 10.77 x 2.62 1/4 Retaining Ring 2-113 13.94 x 2.62 3/8 Retaining Ring 5-256 17.96 x 2.62 1/2 Retaining Ring 2-119 23.47 x 2.62 3/4 Retaining Ring 2-217 29.74 x 3.53 1 Retaining Ring 2-222 37.69 x 3.53 1 1/4 Retaining Ring 2-224 44.04 x 3.53 1 1/2 Retaining Ring Bonded Washer Part No.4 D9DT-2 D9DT-4 D9DT-6 D9DT-8 D9DT-12 D9DT-16 D9DT-20 D9DT-24 D9DT-32

Part Number ED10X1X ED14X1.5X EDR3/8X EDR1/2X ED26X1.5X ED33X2X ED42X2X ED48X2X

Table U20 Port Detail ISO 1179-1

1) Conforms to proposed revision. 2) 90 durometer nitrile is standard for hydraulic applications. 3) See page O5 for O-ring and retaining ring ordering information. 4) See page O6 for details.
Dimensions and pressures for reference only, subject to change.

U29

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

ISO 9974-1 Flat Face Port with Metric Threads


(DIN 3852, Part 1) Metric ISO261, M Thread

(See Note 1)

ISO 9974 Port seal types available from Parker Thead Size (ISO 261) M8 x 1 M10 x 1 M12 x 1.5 M14 x 1.5 M16 x 1.5 M18 x 1.5 M20 x 1.53) M22 x 1.5 M24 x 1.54) M26 x 1.5 M27 x 2 M33 x 2 M36 x 24) M42 x 2 M45 x 24) M48 x 2 D3 (mm) 8 +0.2 10 +0.2 12 +0.2 14 +o.2 16 +0.2 18 +0.2 20 +0.2 22 +0.2 26 +0.2 26 +0.2 27 +0.2 33 +0.3 36 +0.3 42 +0.3 45 +0.3 48 +0.3 D4 (mm) 13 15 18 20 23 25 27 28 30 33 33 41 43 51 50 56 L1 max. (mm) 1 1 1.5 1.5 1.5 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 L2 min. (mm) 8 8 12 12 12 12 14 14 14 16 16 18 18 20 20 22 W (mm) EOlastic Seal (Type E) Part no. ED8X1X ED10X1X ED12X1.5X ED14X1.5X ED16X1.5X ED18X1.5XX ED20X1.5X ED22X1.5X ED26X1.5X ED26X1.5X ED33X2X ED42X2X ED48X2X O-ring and Retaining Ring1) O-ring O-ring ID x section Retaining Ring Size2) (mm) Part No. 3-902 6-074 2-012 2-013 3-907 2-114 2-017 2-018 2-019 2-118 2-119 2-122 2-124 2-128 2-130 2-132 6.07 x 1.63 8.00 x 1.50 9.25 x 1.78 10.82 x 1.78 13.46 x 2.08 15.54 x 2.62 17.17 x 1.78 18.77 x 1.78 20.35 x 1.78 21.89 x 2.62 23.47 x 2.62 28.24 x 2.62 31.42 x 2.62 37.77 x 2.62 40.94 x 2.62 44.12 x 2.62 M8 RR M10 RR M12 RR M14 RR M16 RR M18 RR M20 RR M22 RR M24 RR M26 RR M27 RR M33 RR M36 RR M42 RR M45 RR M48 RR

0.1

0.2

Table U21 Port Detail ISO 9974-1

1) Seal types G and H are not covered in ISO 9974-1. See page O4 for retaining ring and O-ring ordering information. 2) 90 durometer nitrile is standard for hydraulic applications. 3) For diagnostic applications. 4) These sizes are not covered in ISO 9974-1.
Dimensions and pressures for reference only, subject to change.

U30

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

NPTF and BSPT Dimensions


Male NPTF

Female NPTF

Thread Size NPTF 1/8-27 1/4-18 3/8-18 1/2-14 3/4-14 1-11 1/2 1 1/4-11 1/2 1 1/2-11 1/2 2-11 1/2

O.D. Male Thread Large Dia. 0.41 0.55 0.68 0.85 1.06 1.33 1.67 1.91 2.39

D Min. Thread Length 0.31 0.44 0.47 0.59 0.63 0.75 0.78 0.81 0.81

B Min. Tap Drill Depth 1) 0.38 0.47 0.53 0.69 0.75 0.84 0.84 0.88 0.91

E Chmf. Dia. 0.42 0.55 0.69 0.85 1.06 1.34 1.68 1.92 2.39

Table U22 NPTF Dimensions

1) For bottoming taps only.

Male BSPT

Female BSPT

Thread Size BSPT 1/8-28 1/4-19 3/8-19 1/2-14 3/4-14 1-11 1 1/4-11 1 1/2-11 2-11

O.D. Male Thread Large Dia. 0.39 0.53 0.67 0.84 1.06 1.33 1.67 1.90 2.37

D Min. Thread Length 0.31 0.44 0.47 0.59 0.63 0.75 0.78 0.81 0.81

B Min. Tap Drill Depth 1) 0.38 0.47 0.53 0.69 0.75 0.84 0.84 0.88 0.91

E Chmf. Dia. 0.42 0.55 0.69 0.85 1.06 1.34 1.68 1.92 2.39

Table U23 BSPT Dimensions

1) For bottoming taps only.


Dimensions and pressures for reference only, subject to change.

U31

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Tube to Port1) Pairing for Medium Pressure2) Applications


Tube O.D. Inch (Dash Size) 1/8 (-2) 3/16 (-3) 1/4 (-4) 5/16 (-5) 3/8 (-6) 1/2 (-8) 5/8 (-10) 3/4 (-12) 7/8 (-14) 1 (-16) 1 1/4 (-20) 1 1/2 (-24) 2 (-32) Metric (mm) 4 5 6 8 10 12 15 16, 18 20 22 25, 28 30, 35 38, 42 50 Port Thread SAE 5/16-24 3/8-24 7/16-20 1/2-20 9/16-20 3/4-16 3/4-16 7/8-14 1 1/16-12 1 3/16-12 1 5/16-12 1 5/8-12 1 7/8-12 2 1/2-12 ISO M8 x 1 M10 x 1 M10 x 1 M12 x 1.5 M14 x 1.5 M16 x 1.5 M18 x 1.5 M22 x 1.5 M27 x 2 M27 x 2 M33 x 2 M42 x 2 M48 x 2 M60 x 2 NPTF 1/16-27 1/8-27 1/8-27 1/8-27 1/4-18 3/8-18 1/2-14 1/2-14 3/4-14 3/4-14 1-11 1/2 1 1/4-11 1/2 1 1/2-11 1/2 2-11 1/2 BSPP G 1/8-28 G 1/8-28 G 1/8-28 G 1/4-19 G 1/4-19 G 3/8-19 G 1/2-14 G 1/2-14 G 3/4-14 G 3/4-14 G 1-11 G 1 1/4-11 G 1 1/2-11 G 2-11

Table U24 Tube to Port Pairing for Medium Pressure Applications Notes: 1) Ports are in accordance with the standards listed below: SAE J1926-1, ISO 6149-1, NPTF-SAE J476 and BSPP-ISO 1179-1 2) The pressure range covering all the sizes shown is 1000 to 5000 PSI.

Tube to Port1) Pairing for High Pressure2) Applications


Tube O.D. Inch (Dash Size) 1/8 (-2) 3/16 (-3) 1/4 (-4) 5/16 (-5) 3/8 (-6) 1/2 (-8) 5/8 (-10) 3/4 (-12) 7/8 (-14) 1 (-16) 1 1/4 (-20) 1 1/2 (-24) 2 (-32) Metric (mm) 4 5 6 8 10 12 14, 16 20 25 30 38 50 Port Thread SAE 5/16-24 3/8-24 7/16-20 1/2-20 9/16-20 3/4-16 7/8-14 1 1/16-12 1 3/16-12 1 5/16-12 1 5/8-12 1 7/8-12 2 1/2-12 ISO M8 x 1 M10 x 1 M12 x 1.5 M14 x 1.5 M16 x 1.5 M18 x 1.5 M22 x 1.5 M27 x 2 M30 x 2 M33 x 2 M42 x 2 M48 x 2 M60 x 2 NPTF 1/16-27 1/8-27 1/8-27 1/8-27 1/4-18 3/8-18 1/2-14 3/4-14 3/4-14 1-11 1/2 1 1/4-11 1/2 1 1/2-11 1/2 2-11 1/2 BSPP G 1/8-28 G 1/8-28 G 1/8-28 G 1/4-19 G 3/8-19 G 3/8-19 G 1/2-14 G 3/4-14 G 3/4-14 G 1-11 G 1 1/4-11 G 1 1/2-11

Table U25 Tube to Port Pairing for High Pressure Applications Notes: 1) Ports are in accordance with the standards listed below. SAE J1926-1, ISO 6149-1, NPTF-SAE J476 and BSPP-ISO 1179-1 2) Pressure range covering all sizes shown is 2500 to 9000 PSI.

Dimensions and pressures for reference only, subject to change.

U32

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

316L Gas and Fluids Chart


Conveyed Media Gases or Fluids Combustion Gases Cooking Oil Diesel Fuel Freon 12 Gasoline, unleaded Grease Helium Hydraulic Oil Hydrogen Gas Manufactured (Town) Gas Motor Oil Natural Gas Propane Gas Steam Water, Deionized Water, Distilled Water, Fresh Compatibility A A A A A A A A A A A A A A A A A

Recommended for Use with Seal-Lok Lite

Table B7 316L Gas and Fluids Chart Ratings Chemical Effect A = Excellent, 250F max. based upon O-ring.

Dimensions and pressures for reference only, subject to change.

U33

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd

4300 Catalog

General Technical
Return To Index

Chemical Compatibility Chart


Chemical Aluminum Chloride 20% Aluminum Fluoride Aluminum Hydroxide Ammonium Phosphate, Dibasic Ammonium Phosphate, Monobasic Aniline Hydrochloride Antimony Trichloride Aqua Regia (80% HCl, 20% HNO3) Aromatic Hydrocarbons Benzonitrile Bromine Chloric Acid Chlorine Water Chlorine, Anhydrous Liquid Copper Chloride Copper Cyanide Copper Fluoborate Ethyl Sulfate Ferric Chloride Ferrous Chloride Hydrobromic Acid 100% Hydrobromic Acid 20% Hydrochloric Acid 100% Hydrochloric Acid 20% Hydrochloric Acid 37% Hydrochloric Acid, Dry Gas Hydrouoric Acid 20% Hydrouoric Acid 50% Hydrouoric Acid 75% Hydrouosilicic Acid 100% Ink Iodine Lead Sulfamate Magnesium Chloride Melamine Mercuric Chloride (dilute) Mercuric Cyanide Nickel Chloride Nitrating Acid (<15% HNO3) Nitrating Acid (>15% H2SO4) Nitrating Acid (15% H2SO4) Oils: Ginger Pentane Perchloric Acid Phosphoric Acid (>40%) Phosphoric Acid (molten) Phosphoric Acid (40%) Plating Solutions, Chromium Plating: Barrel Chrome Bath 95F Plating Solutions, Chromium Plating: Black Chrome Bath 115F Plating Solutions, Chromium Plating: Chromic-Sulfuric Bath 130F Plating Solutions, Chromium Plating: Fluoride Bath 130F Compatibility C D C C C D D D C D D C C C D B D D D D D D D D D D D D D D C D C D D D C C D C C D C C D C C D C C D

Chemicals NOT Recommended for Use with Seal-Lok Lite


Chemical Plating Solutions, Chromium Plating: Fluosilicate Bath 95F Plating Solutions, Copper Plating (Acid): Copper Fluoborate Bath 120F Plating Solutions, Copper Plating (Acid): Copper Sulfate Bath R.T. Plating Solutions, Gold Plating: Acid 75F Plating Solutions, Gold Plating: 75F Plating Solutions, Indium Sulfamate Plating R.T. Plating Solutions, Iron Plating: Ferrous Am Sulfate Bath 150F Plating Solutions, Iron Plating: Ferrous Chloride Bath 190F Plating Solutions, Iron Plating: Ferrous Sulfate Bath 150F Plating Solutions, Iron Plating: Fluoborate Bath 145F Plating Solutions, Iron Plating: Sulfamate 140F Plating Solutions, Iron Plating: Sulfate-Chloride Bath 160F Plating Solutions, Lead Fluoborate Plating Plating Solutions, Nickel Plating: Fluoborate 100-170F Plating Solutions, Nickel Plating: High-Chloride 130-160F Plating Solutions, Nickel Plating: Sulfamate 100-140F Plating Solutions, Nickel Plating: Watts Type 115-160F Plating Solutions, Rhodium Plating 120F Plating Solutions, Tin-Fluoborate Plating 100F Plating Solutions, Tin-Lead Plating 100F Plating Solutions, Zinc Plating: Acid Chloride 140F Plating Solutions, Zinc Plating: Acid Fluoborate Bath R.T. Plating Solutions, Zinc Plating: Acid Sulfate Bath 150F Sea Water Silver Bromide Sodium Bisulfate Sodium Bromide Sodium Fluoride Sodium Hypochlorite (<20%) Sodium Hypochlorite (100%) Sodium Sulde Stannic Chloride Sulfur Chloride Sulfur Trioxide Sulfuric Acid (10-75%) Sulfuric Acid (75-100%) Sulfuric Acid (hot concentrated) Tartaric Acid Tin Salts Trichloroacetic Acid Compatibility C D D C C C C D C D D D C C C C C D C C D C C C D C C D C D D D D C D D C C D C

Table B8 Chemical Compatibility Chart Ratings Chemical Effect C = Fair Moderate Effect. Not recommended for continuous use. Softening, loss of strength, swelling may occur. D = Severe Effect. Not recommended for ANY use.
Dimensions and pressures for reference only, subject to change.

U34

Parker Hannin Corporation Tube Fittings Division Columbus, Ohio http://www.parker.com/tfd