Professional Documents
Culture Documents
Page 0.02
www.condor-cpc.com
The Company
It all started more than 100 years ago. In 1893 August Frede founded a company which manufactured machinery and equipment
primarily for agricultural purposes. Above all, this included centrifuges and pumps. Tradition has it that the first, or rather one of the first milking machines ever made was designed and manufactured by Condor
In the Thirties - at which time the company was christened Condor - due to it's intensive activity in the field of pump technology, the company was granted a patent which is still relevant up to the present day for diaphragm based pressure
switches manufactured all over the world. That laid the foundation in the field of electronic engineering; the era of Condor switchgear had begun
Within the company, more and more added value is generated by customized individual solutions based on electronic components. Electrical and electronic components as well as individually taylored controls of the highest quality make up a perfect package.
www.condor-cpc.com
Page 0.03
Page 0.04
www.condor-cpc.com
Table of Contents
Page
General
The Company ISO Certificate Table of contents Index 0.03 0.04 0.05 0.06
Electronic Components
Electronic pressure transducer EDI Electronic pressure sensor EDS Electronic pressure control EDR Electronic pressure control EDRA Staging and sequencing control GLW 4 Universal test instrument VARIOTEST Phase-sequence indicator ROTATEST Test device for residual current circuit breakers DELTATEST Adjustable sensor simulator CSG420 Multifunction timer relay FMF Multifunction timer relay IMF
1.01 1.02 1.03 1.04 1.06 1.08 1.11 1.12 1.13 1.14 1.15 1.18
Subsidiaries Condor-Werke
Condor Systems GmbH Scharco Elektronik GmbH Condor USA, Inc.
Pressure switches
Single phase Pressure switch MDR 1 Pressure switch MDR 11 Pressure switch MDR 2 Pressure switch MDR 21 3-phase Pressure switch MDR 3 Pressure switch MDR 4 Pressure switch MDR 5
Level controls
Level control technology Float switches PSN Electronic pump control ENP Electronic level control ENR Electronic level control relay HRH-2 Stainless steel level sensor ENS
www.condor-cpc.com
Page 0.05
A
A IP 55 AEV 1 S AEV 2 .. AEV 2 .. AEV 3 .. AEV 4 .. AEV 5 .. AS AZ Moulded plastic enclosure IP 55 Unloader valve for difficult motor starting condition Unloader valve for difficult motor starting condition Unloader valve for difficult motor starting condition Unloader valve for difficult motor starting condition Unloader valve for difficult motor starting condition Unloader valve for difficult motor starting condition Shunt release Supplementary set for enclosure 6.05, 6.08 3.03, 3.06 3.09 3.12 3.17 3.23 3.27 6.05 6.05 H 124-114 H 124-88 H 124g-127 H1 H1-EA H2 H21 H21-EA H2-EA H3 H3-B .. H3-EA H3-EA-B .. Moulded plastic enclosure Weight for float switches 6.05 5.07 H4 H4 SD H4 S-EA Moulded plastic enclosure Star/Delta Starter Adjustable sensor simulator 6.05 6.13 1.14 H43 H5 H5-K Haube MDR1+ Hi HRH-2 Gauge fitting Blanking plug Console Cover MDR 1 Cover MDR 1 with ON- and OFF-switch Cover MDR 2 Cover MDR 21 Cover MDR 21 with ON- and OFF-switch Cover MDR 2 with ON- and OFF-switch Cover MDR 3 Hourmeter kit and cover MDR 3 Cover MDR 3 with ON- and OFF-switch Hourmeter kit and cover EA MDR 3 Cover MDR 4 Cover for MDR 4 SD, transparent Cover MDR 4 with ON- and OFF-switch Cover MDR 43, transparent Cover MDR 5, MDR 53 Cover MDR 5 with ON- and OFF-switch Supplementary set cover MDR 1 Auxiliary contact Level control relay 4.18 4.18 4.18 3.03 3.03 3.09 3.12 3.12 3.09 3.17 3.16 3.17 3.16 3.23 3.23 3.23 4.12 3.27, 4.14 3.27 3.03 6.05, 6.08 5.14
B
B IP 55 BG-PS
C
C IP 55 C-SDU CSG420
D
DELTATEST RCCB Tester 1.13
E
E IP 54 EDI EDR EDRA EDS ENP ENR ENS EV 1 S EV 2 .. EV 2 .. EV 3 .. EV 4 .. EV 5 .. Frontplate with mounting support Electronic pressure transducer Electronic pressure control Electronic pressure control with digital display Electronic pressure sensor Electronic dual pump control Electronic level control Stainless steel level sensor Unloader valve Unloader valve Unloader valve Unloader valve Unloader valve Unloader valve 6.05 1.02 1.04 1.06 1.03 5.10 5.12 5.16 3.03, 3.06 3.09 3.12 3.17 3.23 3.27
I
IG-PS IMF Weight for float switch Multifunction timer relay 5.07 1.18
K
K-PS Cable holder for float switches 5.07
M
MDR - F .. MDR 1 MDR 11 MDR 2 MDR 21 MDR 3 MDR 4 S MDR 4 SD MDR 4 SU MDR 43 MDR 5 MDR 53 MDR 5-K MDR-1 + Diff. MDR-F D+32 MDR-F D-32 MDR-F Haube MDR-F Haube R MDR-F M20 MDR-F RT-1 MKE2 Control pressure switch Pressure switch Pressure switch Pressure switch Pressure switch Pressure switch Pressure switch Pressure switch Pressure switch Control pressure switch Pressure switch Control pressure switch Pressure switch Differential adjustment MDR 1 / MDR 11 Throttle as of 32 bar Throttle up to 32 bar Cover MDR-F Cover MDR-F for reset switch Cable glands MDR-F Reset push-button Manual motor starter with thermal and magnetic releases Mounting support MDR 3 4.02 3.02 3.05 3.08 3.11 3.14 3.21 3.21 3.22 4.11 3.26 4.13 3.26 3.03, 3.06 4.08 4.08 4.08 4.08 4.08 4.08 6.02
F
FF 142 . FFg 142 . FMF Control pressure switch Control pressure switch Multifunction timer relay 4.16 4.17 1.15
G
G IP 65 GLW 4 GLW 4-S Enclosure in die-cast aluminium Electronic staging and sequencing control Electronic staging and sequencing control without accessories Electronic staging and sequencing control with accessories 6.05 1.08 1.08
1.08
H
H enclosure H 6.11 MW 3
3.17
Page 0.06
www.condor-cpc.com
Index
MW 4 MW 5 Mounting support MDR 4, MDR 43 Mounting support MDR 5, MDR 53 3.23, 4.12 3.27, 4.14 ROTATEST RU .. Phase-sequence indicator Undervolage release 1.12 3.17
S
SK 3 SK 3-S Contact block Contact block with lock mechanism Thermal overlaod relay 3.17 3.17 3.17
N
NAK Emergency-OFF-device IP 54 6.05
SK R3 / ..
O
OKE2 OKN Manual motor starter with thermal releases Manual motor starter with thermal releases 6.02 6.10
T
TEL-.. TFA 2 TFE 2 Immersion electrode Protective device for motors with thermocontacts Protective device for motors with thermocontacts 5.14 6.08 6.08
P
PG .. -1 PG .. 11/21 PG .. 2/4/43 PG .. 3 PG .. 5/53 PS 1 PSN-.. PSN-.. +ST PSN-O DB PSN-X SP Cable glands MDR 1 Cable glands MDR 11, MDR 21 Cable glands MDR 2, MDR 4, MDR 43 Cable glands MDR 3 Cable glands MDR 5, MDR 53 Control pressure switch Float switches Float switches with plug Float switch, special versions Float switch, special versions 3.03 3.06, 3.12 3.09, 3.22, 4.12 3.17 3.27, 4.14 4.20 5.07 5.07 5.07 5.07
U
US Undervoltage release 6.05
V
V VARIOTEST Padlock blockade device Acoustic universal test instrument 6.05 1.11
W
WN WN .. 11/21/3 WN .. 2/4/43 Cable grommet MDR 1 Cable grommet MDR 11, MDR 21, MDR 3 Cable grommet MDR 2, MDR 4, MDR 43 Cable grommet MDR 5, MDR 53 3.03 3.06, 3.12, 3.17 3.09, 3.23, 4.12 3.27, 4.14
R
R5 .. RA .. R-AD 10 .. R-AD 6 Thermal overload relay Shunt release Ermeto-connector Ermeto-connector 3.27 3.17 4.18 4.18
WN .. 5/53
www.condor-cpc.com
Page 0.07
Page 0.08
www.condor-cpc.com
Electronic Components
EDS
1.03
EDR
1.04
EDRA
1.06
GLW 4
1.08
Test devices
VARIOTEST
The Condor-VARIOTEST is a universal test instrument featuring acoustic signals for: The Condor-ROTATEST is a Phase-sequence indicator with optical display The Condor-DELTATEST is a test device for residual current circuit breakers The Condor-CSG420 is an adjustable sensor simulator 4-20 mA Page 1.11
ROTATEST
1.12
DELTATEST
1.13
CSG420
1.14
IMF
Multifunction timer relay featuring installation type dimensions 4 switchable time ranges universal current
1.18
www.condor-cpc.com
Page 1.01
Max. inaccuracy at 25 C
2.5 % 2.5 %
Part No.
3700080 3700090
Output signal
4 - 20 mA
Enclosure
-20 C up to + 60 C 10% up to 90% -40 C up to + 80 C VDE 0110 any position max. 1 VA Material Mounting Enclosure-protection Protection against shock Terminals Cross section Weight RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
Pressure connection
Quick-connect suitable pneumatic tube 6 x 1 mm Festo PAN
Page 1.02
www.condor-cpc.com
Max. inaccuracy at 25 C
2.5 % 2.5 % 2.5 %
Part No.
1090210008 1090210007 1090210001
Accessories EDS
Order reference
EDS-ST
Description
connection socket EDS, DIN 43650-A
Weight in g
110
Part No.
1090210002
Pressure connection
G 1/4
Output signal
4 - 20 mA
Enclosure
Enclosure-protection Terminals Cross section Weight max. IP 65 Quick connects Quick connects 4,5 mm 150 g
www.condor-cpc.com
Page 1.03
Part No.
3700010 3700030
Accessories EDR
Order reference
KL-S
Description
Jack 2.5 mm for analogue output connection (cable length 5 m)
Weight in g
15
Part No.
3709400
Enclosure
RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
Output signal
Analogue voltage signal max. 5 mA short-circuit proof 0 - 10 V
Page 1.04
www.condor-cpc.com
Dimensions EDR
www.condor-cpc.com
Page 1.05
Max. inaccuracy at 25 C
2.5 %
Part No.
3700060
Enclosure
RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
Power section
max. 1 VA Series voltage acc. to VDE 0660 and VDE 0110 Group C Maximum continuous current per contact Maximum switching capacity per contact Mechanical life Cycles Electrical life (max load) Cycles 250 V-AC 6 A-AC 1.500 VA (AC) 50 W (DC) 7 approx. 1 x 10 approx. 2 x 10
5
Pressure connection
Quick-connect suitable pneumatic tube e.g. 6 x 1 mm Festo PAN
Page 1.06
www.condor-cpc.com
Dimensions EDRA
www.condor-cpc.com
Page 1.07
Following functions can be activated: Internal pressure transducer 0 to 16 bar Connection of an external pressure transducer, two-wire 4 to 20mA Programmable internal time switch (controls up to 6 profiles) Programmable primary load and load changeover functions, allowing for the primary load compressor to operate without taking part in the rotation process. Only the load changeover compressors are rotated. Programmable ball valve control with max. 3 compressors Direct switchover after the load changeover time has elapsed. Four digital inputs (e.g. for hourmeter ) Input: bridge time switch Input: remote release Parameter password protection Units reversible bar/psi
Description
GLW 4 without wiring, enclosure
Part No.
237761
GLW 4-S
GLW 4 in pre-wired plastic enclosure, (dimensions: 420x300 x170mm), DIN-Rail mounting, internal terminal blocks and wiring diagram. GLW 4 in pre-wired plastic enclosure, (dimensions: 420x300 x170mm), DIN-Rail mounting, internal terminal blocks and wiring diagram. Additionally wired for 4 compressors: isolator, rotary switch bridge timer, rotary switch compressor 1 - 4, indicator lamps for voltage supply and compressors 1 4.
291534
291527
Page 1.08
www.condor-cpc.com
= = = = = = = =
A1 A2
I11 I21 I31 I41 I51 I61 I12 I22 I32 I42 I52/62 14
12 11
24 22
21 34
32 31
44 42
41 54
52 51
p+ p-
OK
4 digital Inputs, 250V AC1, e. g. operating hours External release input, 250V AC1 Bridge time switch input, 250V AC 1 Isolated SPDT outputs for max. 4 compressors 230V AC, max. 5A AC1 Isolated alarm relay 230V AC, max. 5A AC1 External analogue connection 4 - 20mA Two wire Ub= 18-21V DC V 24-Interface for PC programming
GLW 4
COM Control & Solution
p+ / pCOM
A1; A2; I51 and I52/62 must be connected to enable basic functionality. No special programming knowledge is required.
GLW 4
Technical Data
Technical operating data
Permissible operating voltage range Operating voltage influence at 10% operating voltage fluctuation Duty factor Permissible ambient and media temperature Permissible ambient humidity rel. humidity, non-condensing Permissible storage temperature Clearance and creepage distances 90 265 V AC 50 60 Hz <0.1% 100% -20 C up to +60 C 10% up to 90% -40 C up to +80 C VDE 0110 4 Relay outputs isolated SPDT's 1 Alarm relay isolated SPDT Internal buzzer 4 digital inputs 250V Input 250V-AC1 (I51/52) Bridge time switch
Analogue Interface
Working position Power consumption Control Any position 10 VA Input analogue pressure transducer UB 4 - 20 mA, 2 wire Integrated pressure transducer With quick connect 18 21V-DC 016 bar
Power section
Series voltage acc. to VDE 0660 and VDE 0110 Group C Maximum continuous current per contact Maximum switching capacity per contact Mechanical life Cycles Electrical life (max load) Cycles 250 V-AC 6 A-AC 1.100 VA (AC) 50 W (DC) approx. 1 x 7 10 approx. 2 x 5 10 Material Mounting Enclosure-protection
Enclosure
RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
Pressure connection
Pneumatic tube diameter suitable pneumatic tube e.g. 6 x 1 mm Festo PAN
Page 1.10
www.condor-cpc.com
VARIOTEST
The Condor-Variotest is a universal test instrument featuring acoustic signals for: Continuity and/or resistance testing up to 20 k Direct and alternating voltage checking up to 500 V Polarity test for D.C. from 6 V to 500 V Phase checking (outer conductor) Mp conductor and protective conductor Checking function of RCCB's with IN max. 30 mA Semi-conductor testing The Condor-VARIOTEST
- is protected against external voltages up to 500 V and limits the current input to max. 4 mA. Destruction as a result of incorrect handling is practically impossible. - distinguishes between D.C. and A.C. voltages or a resistance value by sound pitch and frequency change respectively. - is equipped with an ON-OFF switch. - is supplied with the battery inserted and is ready for immediate use. - Measuring probes and leads acc. to IEC 1010 Part 2-031.
Type overview
Order reference
VARIOTEST
Packing (units)
1
Weight in g
115
Part No.
3066100
Dimensions
Audio frequency
Leads
80 cm
Measuring probes
crush proof
Protection
www.condor-cpc.com
Page 1.11
ROTATEST
The Condor-Rotatest indicates the phase sequence in a three-phase mains circuit and thus the direction of rotation for electromotive appliances.
The additional phase monitoring glow lamps also indicate whether all the outer conductors are live and ensure that the neutral and outer conductors have not been interchanged.
VDE 0100 stipulates: Three-phase sockets shall be connected in such a manner that a rotation field to the right is reached when looking at the front of the sockets clockwise.
Type overview
Order reference
ROTATEST
Packing (units)
1
Weight in g
195
Part No.
3066300
Technical Data
Technical operating data
Voltage range 250 V up to max. 650 V 5 mA
Dimensions
100 %
80 cm
Measuring probes
crush proof
Page 1.12
www.condor-cpc.com
DELTATEST
The Condor-Deltatest is used for testing residual current circuit breakers and electrical installations which are monitored by them. It "simulates" at any point of the installation (much easier is a socket outlet) a fault current with an effective duration (< 200 ms) according to Specifications and which value is set by a selector switch to the rated fault current of the previously connected RCCB (10, 30, 100, 300 and 500 mA).
The Condor-Deltatest is not a measuring instrument in the sense of VDE 0413 and therefore may not be used for measurements acc. to VDE 0100 Part 600.
VDE 0664 Part 1 stipulates: That the breaking delay time of an RCCB shall not exceed 0.2 seconds for A.C. rated operating fault currents and at 1.4 times the rated operating fault current of pulsating D.C. currents. Measuring probes and leads acc. to IEC 1010 Part 2-031.
Type overview
Order reference
DELTATEST
Packing (units)
1
Weight in g
115
Part No.
3066400
Technical Data
Technical operating data
Voltage range 250 V ~
Dimensions
Test cycle
approx. 5 s
Leads
80 cm
Measuring probes
crush proof
Protection
www.condor-cpc.com
Page 1.13
CSG420
The sensor simulator Condor-CSG420 is used to simulate a level sensor (4 20 mA) on an electronic control unit
Features LCD Display Functions selector switch Potentiometer for current adjustment
Type overview
Order reference
CSG420
Packing (units)
1
Weight in g
220
Part No.
249634
Technical Data
Technical operating data
Adjustable current range 3.5 mA up to 25.5 mA 8.5 V up to 32 V
Dimensions
Display accuracy
Leads
Page 1.14
www.condor-cpc.com
Multifunction relay in compact industrial standard casing 8 selectable time ranges Universal current 2 SPDT's Remote-control terminal Voltage activation
The multifunction timer relay FMF is specifically prevents destruction of the devices due to faulty designed for rough industrial environments. All wiring. inputs and outputs are both interference free and Adjustable functions: non-destructive at voltage surges of up to 2 kV. Contact activation may be carried out not only by delay on make conventional means such as an isolated contact delay on break (between A1 and B1) but also by applying the on-delay single shot operating voltage to B1. This helps to reduce flashing wiring and contact requirements of the control and Remote control: A remote control can be realised with 2 wires connected to the terminals Z1 / Z2 and a 100 k potentiometer, whereby the FMF potentiometer must be set to 0.
Time
0.1 s ca. 7 h
SPDT's
2
Part No.
230403
Output contacts
Series voltage acc. to VDE 0660 and VDE 0110 Group C Maximum continuous current 1 change over, 2-change -over Maximum switching capacity per contact Mechanical life Cycles Electrical life (max load) Cycles Resistance of remote-control Standard 250 V-AC 6 A-AC
1.500 VA (AC)
www.condor-cpc.com
Page 1.15
General data
Tolerance range Repeatability Temperature range Recovery time 10% 0.5 % approx. 0,2 % / C < 100 ms
Time ranges
2 x 1.5 mm 200 g Initial value 0,05 s 0,2 s 1,6 s 12.5 s 5s 20 s 160 s (approx. 2.7 min.) 1250 s (approx. 21 min.) End value 1s 4s 32 s 250 s 100 s 400s 3200 s (approx. 53 min.) 25000 s (approx. 417 min.)
Page 1.16
www.condor-cpc.com
Delay on make
Delay on break
Operating voltage UB
Output
www.condor-cpc.com
Page 1.17
Multifunction relay featuring installation type dimensions 4 selectable time ranges Universal current 1 SPDT Contact activation
The multifunction timer relay IMF is specifically designed for rough industrial environments. All inputs and outputs are both interference free and non-destructive at voltage surges of up to 2.000 V. Contact activation may be carried out not only by conventional means such as a voltage-free contact (between A1 and B1), but also by applying the operating voltage to B1. This helps to reduce wiring and contact requirements of the control and
prevents destruction of the devices due to faulty wiring. Adjustable functions: delay on make delay on break on-delay single shot flashing
Time
0.6 s 60 min
SPDT
1
Part No.
230410
Output contacts
Series voltage acc. to VDE 0660 and VDE 0110 Group C Maximum continuous current 1 change over, 2-change -over Maximum switching capacity per contact Mechanical life Cycles Electrical life (max. load) Cycles 250 V-AC 6 A-AC
1.500 VA (AC)
Page 1.18
www.condor-cpc.com
Enclosure data
Material Mounting Enclosure-protection Protection against shock Terminals Cross-section Weight RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
General data
Tolerance range Repeatability Temperature range Recovery time 10% 0.5 % ca. 0.2 % / C < 100 ms
Time ranges
2.5 mm 75 g Initial value 0.6 s 6s 0.6 min 6 min End value 6s 60 s 6 min 60 min
www.condor-cpc.com
Page 1.19
Operating voltage UB
Output
Page 1.20
www.condor-cpc.com
Overview
Setting reference A short overview regarding pressure and pressure differential settings of a pressure switch
Page 2.02
High performance pressure switches for AC currents Technical data synoptic tables which enable quick selection of a required pressure switch High performance pressure switches for 3-phase currents Technical data synoptic tables which enable quick selection of a required pressure switch Control pressure switches Technical data synoptic tables which enable quick selection of a required control pressure switch
2.04
2.05
2.06
Type code For high performance pressure switches and control pressure switch MDR 43 and MDR 53 For decoding match codes of the different pressure switch types and accessories Type code for control pressure switch MDR-F For decoding match codes of the different pressure switch types and accessories
2.08
2.10
Media resistance tables For selecting a suitable pressure switch for a given media
2.11
www.condor-cpc.com
Page 2.01
Page 2.02
www.condor-cpc.com
Repeatability The permissible tolerance of the switching values (repeatability) lies at under < 3% of the upper range value. Service Our service offers you the possibility of carrying out pressure settings depending on your requirements. We, of course, can also mount any accessories you may need on demand, profiting at the same time from a complete warrantee.
www.condor-cpc.com
Page 2.03
Type designation* Media * No. of poles Contact function Voltage Motor switching capacity Rated current Flange types *
MDR 1
air 2 pole 2 N.C. 230 V 4.0 kW 20 A G 1/4 F4 1/4 F4 3/8 F4 1/4 NPT 1 2.5 - 11 IP 44 -570 C
MDR 1
water 2 pole 2 N.C. 230 V 4.0 kW 20 A G 1/4 steel G 1/4 steel * 1 2.5 - 6 IP 44
MDR 11
air 2 pole 2 N.C. 230 V 4.0 kW 20 A G 1/4 F4 1/4 F4 3/8 1 2.5 - 11 IP 41/44 -570 C
MDR 11
water 2 pole 2 N.C. 230 V 4.0 kW 20 A G 1/4 steel G 1/4 steel * 1 2.5 - 6 IP 41/44
MDR 2
air 2 pole 2 N.C. 230 V 2.2 kW 16 A G 1/4 F4 1/4 F4 3/8 F4 1/2 2 1.5 12 IP 44 -580 C
MDR 21
air 2 pole 2 N.C. 230 V 4.0 kW 24 A G 1/4 F4 1/4 F4 3/8 F4 1/2 F4 1/4 NPT 2 1.5 12 IP 41/44 -580 C
Pressure ranges (bar) Cut-out pressure from - to Degree of Protection Permissible media temperature: Air Permissible media temperature: Water Max. cross-section (fine stranded) Standard Cable glands Standard On / Off lever Standard Differential setting Standard Delayed (AEV) Unloader valve (EV)
70 C 2.5 mm with PG 11 Z/ZK with/without EA without differential setting (only as accessory) with AEV (Accessory EV) 2.5 mm with PG 11 Z/ZK Without EA without differential setting (only as accessory) without 2.5 mm with PG 13.5 Z/ZK with EA without differential setting (only as accessory) with AEV (Accessory EV)
70 C 2.5 mm with PG 13.5 Z/ZK with EA without differential setting (only as accessory) without 2.5 mm with 2xWN * (Accessory PG11 - 13) with/without EA with differential setting without (Accessory EV, AEV)
4
2.5 mm with 2xWN * (Accessory PG11 - 13) with/without EA with differential setting without (Accessory EV, AEV)
4
* Table refers to catalogue product * Preferred / most used media, further media, see table on page 2.11 or on demand * e.g. four-way flange F4 3/8 (main connection G3/8, additionally 3 x G 1/4 ports) * = switch need not be turned, use swivel nut for mounting *4 WN = grommet
Page 2.04
www.condor-cpc.com
Type designation* Media * No. of poles Contact function Voltage * Motor switching capacity Rated current Flange types *
2 3 1
MDR 3
Air and water 3 pole 3 NC 400 V 7.5 kW (11 kW) 24 A G 1/2" G 1/4 F4 1/2" F4 3/8 F4 1/4" F4 1/4" NPT 5 1.3 35 IP 54 -580 C 80 C 4.0 mm with 2 x WN * (Accessory PG11 - 16) with/without EA with differential setting without (accessory EV, AEV)
4
MDR 4 S
Air and water 3 pole 3 NC 400 V 5.5 kW 20 A G 1/2" G 1/4 G 1/2 + G 1/4
MDR 4 SD
Air and water 3 pole 3 NC 400 V 5.5 kW 20 A G 1/2" G 1/4
MDR 4 SU
Air and water 3 pole 3 NO 400 V 4 kW 16 A G 1/2"
MDR 5
Air and water 3 pole 3 NC 400 V 5.5 kW 25 A G 1/2" G 1/2 + G 1/4
Pressure ranges (bar) Cut-out pressure from - to Degree of Protection Permissible media temperature: Air Permissible media temperature: Water max. cross-section (fine stranded) Standard Cable glands Standard On / Off lever Standard Differential setting Standard delayed (AEV) unloader valve (EV)
3 1.5 16 IP 44 -580 C 80 C 2.5 mm with 2 x WN * (Accessory PG11 - 13) with/without EA with differential setting without (accessory EV, AEV)
4
2 1.5 11 IP 44 -580 C 80 C 2.5 mm with 2 x WN * (Accessory PG11 - 13) without EA with differential setting without (accessory EV, AEV)
4
3 1.5 16 IP 44 -580 C 80 C 2.5 mm with 2 x WN * (Accessory PG11 - 13) without EA with differential setting without
4
4 1.5 16 IP 54 -580 C 80 C 2.5 mm without (Accessory PG11 - 16) with/without EA with differential setting without (accessory EV, AEV)
* Table refers to catalogue product * Preferred / most used media, further media, see table on page 2.11 or on demand * e.g. four-way flange F4 3/8 (main connection G3/8, additionally 3 x G 1/4 ports) *3 Higher voltages on demand *4 WN = grommets
www.condor-cpc.com
Page 2.05
Overview
MDR F..H Type designation Contact function Voltage Motor switching capacity Current AC 15 Flange types Standard (bold)
Die-cast aluminum
MDR-F..Y
Plastic
MDR-F..HE
Stainless steel
MDR-F..HH
High pressure
MDR-F..
Reset function
1 SPDT* 230 V 0.55 kW 4A G 3/8" G 1/2" G 1/4 1/4 NPT Inner thread (Die-cast aluminum) 6 0.11 - 32 IP 54 / IP 65 WN / M 20 70 C
Pressure ranges (bar) Cut-out pressure from - to Degree of Protection Cable glands Permissible media temperature
5 0.11 - 16 IP 54 / IP 65 WN / M 20 70 C
2 1 - 30 IP 54 / IP 65 WN / M 20 200 C
3 8 - 250 IP 54 / IP 65 WN / M 20 70 C
Page 2.06
www.condor-cpc.com
Overview
Type designation Contact function Voltage Motor switching capacity Current AC 15 Flange types
MDR 43 1 NC 1 NO 230 V 1.1 kW 8A G 1/2 G 1/4 Inner thread (Die-cast aluminum) 4 0.5 - 16 bar IP 44 PG 11 13.5 80 C
FF 142 2 SPDT's* 230 V 0.55 kW 6A G 3/8 Inner thread (Plastic) G 1/4 Outer thread (Steel) 7 -0.4 - 40 bar IP 55 PG 13.5 - 30 .. + 70 C
FFg 142 2 SPDT's* 230 V 0.55 kW 6A G 3/8 Inner thread (Plastic) G 1/4 Outer thread (Steel) 6 -0.4 - 40 bar IP 65 PG 13.5 - 30 .. + 70 C
Pressure ranges Cut-out pressure from to Degree of Protection Cable glands Permissible media temperature
4 0.3 - 16 bar IP 54 PG 11 16 80 C
www.condor-cpc.com
Page 2.07
Type code
For high performance pressure switches and control pressure switches MDR 43 and MDR 53 For decoding of pressure switch types: Standard settings
MDR X
See next page For details
Pressure ranges
3 bar / 43.5 psi / 300 kpa 5 bar /72.5 psi / 500 kpa 6 bar /87 psi / 600 kpa 8 bar /116 psi / 800 kpa 9 bar / 130.5 psi/ 900 kpa 11 bar /159.5 psi / 1100 kpa 16 bar /232 psi / 1600 kpa 25 bar /362,5 psi / 2500 kpa MDR 3 35 bar / 507,5 psi/ 3500 kpa MDR 3 3 bar, pressure-resistant up to 25 bar MDR 5 8 bar, pressure-resistant up to 25 bar MDR 5 B C D E F G H I J N O
Flange
G 1/2" G 1/4" G 3/8" G 1/2", 4-Way G 1/4", 4-Way G 3/8", 4-Way 1/4", NPT 3/8", NPT 1/4", NPT, 4-Way 3/8", NPT, 4-Way G 1/2", Gauge connection 1/4" G 1/4", Gauge connection 1/4" G 3/8", Gauge connection 1/4" G 1/4", Steel G 1/4", Steel, with swivel nut A B C D E F H I K L O P Q S T
Diaphragm
Standard For tight pressure differential (roller diaphragm) Suitable for use with foodstuffs A B D
Version
EURO-Standard with screw terminals US-Standard with screw terminals EURO-Standard screw terminals and UL Standard with quick-connects Large wiring space (MDR 4S)
Reverse switching function, large wiring space (MDR 4SU)
Pressure (units)
A B C D E Bar (> 1 bar => 010) psi Kpa (> 100 kpa => 010 Bar (< 1 bar => 100)
Kpa (< 100 kpa => 100)
Cut-out pressure
xxx
Pressure in figures number) (3-figure
Printing
Condor A
Page 2.08
www.condor-cpc.com
Type code
For high performance pressure switches and control pressure switches MDR 43 und MDR 53 For De-coding of pressure switch types: Accessories
MDR X
X A B G
X A B C D E F G
A G used by MDR 3
Valves
Without unloader valves Unloader valves EV, screw fitting 6 mm Unloader valves EV i, screw fitting 1/4" Unloader valves EV S, quick-connect 6 mm Unloader valves EV W, 90, screw fitting 6 mm Unloader valves EV Wi, 90, screw fitting 1/4" Unloader valves EV WS, 90, quick-connect. 6 mm Unloader valves EV M5, screw fitting 6 mm, port fitting M5 Unloader valves EVi M5, screw fitting 1/4", port fitting M5 Unloader valves EV WSi, 90, quick-connect 1/4" Unloader valves EV Ei, screw fitting 1/4" Unloader valves EV L, screw fitting 6 mm, port fitting 6 mm Unloader valves EV Li, screw fitting 1/4", port fitting 6 mm Unloader valves AEV, screw fitting 6 mm Unloader valves AEV i, screw fitting 1/4" Unloader valves AEV S, quick connect 6 mm Unloader valves AEV W, 90, screw fitting 6 mm Unloader valves AEV Wi, 90, screw fitting 1/4" Unloader valves AEV WS90, quick-connect 6 mm Unloader valves AEV WSi, 90, quick-connect 1/4" Unloader valves EV E, screw fitting 6 mm for MDR 5, 6 Unloader valves EV 5, screw fitting 6 mm, port fitting 6 mm Unloader valves EV Si, quick-connect 6 mm
X A B C D E F G H I J M N O P Q R S T U V W Y
X C D E F G H I J K L M N O P Q R S T U V W Y
Releases (Note use off small/capital initial letters) Without overload relay Without contact block Overload relay 0.63 1.0 A Overload relay 1.6 2.5 A Overload relay 1.0 1.6 A Overload relay 2.5 4.0 A Overload relay 4.0 6.3 A Overload relay 6.3 10.0 A Overload relay 10.0 16.0 A Overload relay 16.0 20.0 A Overload relay 20.0 24.0 A Overload relay 20.0 30.0 A, 2 pole
Overload relay 10.,0 16.0 A, for higher switching capacity Overload relay 16.0 20.0 A, for higher switching capacity Overload relay 20.0 24.0 A, for higher switching capacity
Overload relay 0.86 1.5 A Overload relay 1.5 2.45 A Overload relay 2.4 4.2 A Overload relay 4.0 7.0 A Overload relay 6.1 10.3 A Overload relay 9.0 14.0 A Overload relay 11.0 18.0 A Overload relay 18.0 25.0 A - 2 pole
Cable glands
Without cable glands Cable grommets / blanking plug PG 11 conduit PG 11 Complete PG 11 Z with strain relief
PG 11 ZK with strain relief and cable support
strain relief and cable support strain relief and cable support
PG 16/13,5 ZK with
www.condor-cpc.com
Page 2.09
Pressure range
2 bar 4 bar 8 bar 10 bar 12 bar 16 bar 30 bar 32 bar 60 bar 120 bar 250 bar 002 004 008 010 012 016 030 032 060 120 250 A B C D E F G H
Output contacts
A B Microswitch, 1 SPDT Microswitch, 1 SPDT, gold-flashed
Terminals
A S Cage clamps Screw terminals
Page 2.10
www.condor-cpc.com
Diaphragm resistance
MDR F
(high pressure)
MDR 43 MDR 53
4.06, 4.08 CR + PA6.6 603 C 1 1
MDR 3 RM
3.14 CR 1031/55 2 1 1 X 1
MDR 1 MDR 11
3.02, 3.05 TPE Hytrel 1 1
PS 1
4.20 Messing 1 1 X X 1
Acetone CH3COCH3 Acetylene HC = CH Air Ammonia, watery 100 % Ammonia, 25 % (ammonia solution) Benzene Butane C4H10 Butyl acetate CH3COOC4H9 Butyl alcohol CH3-CH2-CH2-CH2OH Carbon dioxide CO2 Carbonic acid H2CO3 Chlorine Cl2 Cooling liquid Diesel Dimethylbenzene C6H4(CH3)2 Ethyl acetate CH3OOOC2H5 Ethylene glycol CH2OH- CH2OH Fuel oil Gasoline Glycerol CH2OH-CHOH-CH2OH Hydrogen H2 Methyl chloride CH3Cl Mineral oils Natural gas Nitrogen N2 Oxygen O2 Ozone Perchlorethylene CCI2=CCL2 Petroleum Phenolic acid C6H5(OH) Propane C3H8 Protective gas Silicon oil Sulphur dioxide SO2 Silicon oil Synthetic oils Toluene (Phenylmethane) C6H5CH3 Trichlorethene CHCI=CCI2 Urine Vegetable oil Vinegar 25 % Water H2O Water Distilled, aired Water sea water Water steam
1 X
2 1 2
1 1 1
1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 X X X 2 1 X 2 1 1 X 2 1 1 2 X 2 1 1
1 1 2 2 2 1 2 1 1 2 1 1 1 X 1
1 1 1 1 1 1 1 1
1 1 1 1 1
1 1 1
1 1 2 1
1 1
1 1 1 1 1
1 1
1 1 1 1 1
1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 2 X 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1 1 1
1 1 1 1 1 1 1
1 1 1 1 1
1 = resistant, 2 = limited resistance, x = not resistant, empty field = not tested The data in the table results not only from laboratory tests but also from year long experience. These serve as reference points. Since the chemical effect of a given media may be affected by additives, temperature differences and mixtures amongst themselves, we recommend carrying out a media resistance test before using the product.
www.condor-cpc.com
Page 2.11
Page 2.12
www.condor-cpc.com
MDR 11
AC current; switching capacity 4.0 kW Max. cut-out pressure 11 bar / 160 psi UL / CSA-approval AC current; switching capacity 2.2 kW Max. cut-out pressure 12 bar
3.05
MDR 2
3.08
MDR 21
AC current; switching capacity 4.0 kW Max. cut-out pressure 12 bar / 175 psi UL / CSA-approval
3.11
MDR 4
3.21
MDR 5
3-phase; switching capacity 5.5 kW available with overload relays Max. cut-out pressure 16 bar
3.26
www.condor-cpc.com
Page 3.01
Flange
G 1/4" ST G 1/4" ST-
Weight in g
220 220
Part No.
212119 212126
Flange
G 1/4" F4 F4 3/8 G 1/4" F4 1/4 " F4 3/8
Weight in g
220 220 220 220 220 220
Part No.
212133 212140 212157 216049 216025 216063
MDR-1 GBA AAEA 060A080 QDE XXX EA MDR-1 GEA AAEA 060A080 QDE XXX EA MDR-1 GFA AAEA 060A080 QDE XXX EA MDR-1 GBA BAEA 060A080 QDE XXX MDR-1 GEA BAEA 060A080 QDE XXX MDR-1 GFA BAEA 060A080 QDE XXX Unloader valves and cable glands for retrofitting see Accessories!
120 600
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
Page 3.02
www.condor-cpc.com
Accessories MDR 1
Order reference
EV 1S
Description
Unloader valves with quick-connect 6 mm for plastic unloader valves Delayed unloader valves with quick-connect 6 mm for plastic unloader valves Cable glands Grommet Conduits for mounting of cable glands (Inner thread) With strain relief With strain relief and cable support Cover Cover without On/Off lever (Neutral version, without marking) Cover with On/Off lever for manual On/Off (Neutral version, without marking) Conversion kit H1 to cover H1-EA Differential adjustment Kit for setting cut-in and differential pressures (10 pcs.)
Weight in g
25
Part No
226765
AEV 1S
25
217541
WN PG 11 G PG 11 Z PG 11 ZK
6 6 12 12
H1
(Cover MDR 1) H1-EA (Cover MDR 1+EA)
40 40 40
20
230618
EV 1S
AEV 1S
EV 1S / AEV 1S
www.condor-cpc.com
Page 3.03
Grommet
PG 11 G
PG 11 Z
PG 11 ZK
Explanation
Devices without differential pressure adjustment After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. If only the cut-out pressure is known, the cut-in pressure to be set can also be determined from the diagram. Example: MDR 1/6 without differential pressure adjustment For a preselected cut-in pressure of 4 bar, the cut-out pressure is 5 bar. If, for example, the cut-out pressure is to be 4 bar, a cut-in pressure of approx. 2.7 bar has to be set. Devices with differential pressure adjustment An intersecting point is determined in the diagram by selecting a pair of cut-in and cut-out pressure values. If this point lies within the shaded area, this pair of values can be set on the pressure switch. If this point lies outside the shaded area, these values cannot be set. Example: MDR 1/11 with differential pressure adjustment With a preselected cut-in pressure of 4 bar, the cut-out pressure can be determined and set between 5.4 and 8 bar using the differential pressure adjustment
Page 3.04
www.condor-cpc.com
Flange
G 1/4" ST G 1/4" ST-
Weight in g
300 320
Part No.
235712 235729
ON / OFF lever
EA EA
Flange
G 1/4" F4
Weight in g
300 320
Part No.
235736 235743
> 5 x 10
120 600
2.5 / 2.5mm
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
www.condor-cpc.com
Page 3.05
Accessories MDR 11
Order reference
EV 1 S EV 1 WSi
Description
Unloader valves with quick-connect 6 mm for plastic unloader valves 90 unloader valve with quick-connect for 1/4 plastic tubes, quick-connect can be rotated 360 Delayed unloader valves with quick-connect 6 mm for plastic unloader valves Cable glands Grommets With strain relief With strain relief and cable support Differential pressure adjustment Kit for setting cut-in and differential pressures (10 pcs.)
Weight in g
25 25
Part No.
226765 247593
AEV 1 S
25
217541
6 12 12
20
230618
EV 1S
EV 1WSi
AEV 1S
WN
PG 13.5 Z-21
PG 13.5 ZK-21
Page 3.06
www.condor-cpc.com
EV 1S / AEV 1S
EV 1WSi
Explanation
Devices without differential pressure adjustment After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. If only the cut-out pressure is known, the cut-in pressure to be set can also be determined from the diagram. Example: MDR 1/6 without differential pressure adjustment For a preselected cut-in pressure of 4 bar, the cut-out pressure is 5 bar. If, for example, the cut-out pressure is to be 4 bar, a cut-in pressure of approx. 2.7 bar has to be set. Devices with differential pressure adjustment An intersecting point is determined in the diagram by selecting a pair of cut-in and cut-out pressure values. If this point lies within the shaded area, this pair of values can be set on the pressure switch. If this point lies outside the shaded area, these values cannot be set. Example: MDR 1/11 with differential pressure adjustment With a preselected cut-in pressure of 4 bar, the cut-out pressure can be determined and set between 5.4 and 8 bar using the differential pressure adjustment
www.condor-cpc.com
Page 3.07
Flange
G 1/4" G 1/4" F4 1/4" F4 3/8" F4 1/2" F4 1/4" F4 1/4" F4 1/4" F4 3/8" F4 1/2"
Weight in g
300 300 320 320 320 300 300 320 320 320
Part No.
212164 212171 212188 212195 212201 217381 217404 219408 226888 226895
2.5 / 2.5mm
120 600
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
Page 3.08
www.condor-cpc.com
Description
Unloader valves With screw connection for 6 mm plastic or copper discharge tubes With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or discharge copper tubes 90 with screw connection for 1/4" mm plastic or discharge copper tubes
Weight in g
25 25 25 15 15
Part No.
200666 200680 200697 200703 200710
90 with quick-connect for 6 mm plastic discharge tubes Delayed unloader valves With quick-connect for 6 mm plastic discharge tubes 90 with screw connection for 6 mm plastic or copper discharge tubes 90 with screw connection for 1/4" mm plastic or copper discharge tubes 90 with quick-connect for 6 mm plastic discharge tubes Cable glands Grommet Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Cover Cover without On/Off lever (Neural version without marking) Cover with On/Off lever for manual On/Off (neutral version, without marking)
25 15 15 15
6 6 12 12 12 6 12 12 12
H2
(Haube MDR 2) H2-EA (Haube MDR 2+EA)
40 40
217510 229445
EV 2
EV 2S
AEV 2S
EV 2W / EV 2Wi
EV 2WS
AEV 2WS
www.condor-cpc.com
Page 3.09
WN
PG .. G
PG .. V
PG .. Z
PG .. ZK
EV 2
EV 2S
AEV 2S
Pressure Diagrams
Page 3.10
www.condor-cpc.com
Flange
G 1/4" F4 1/4" G 1/4" F4 1/4" G 1/4" F4 1/4" G 1/4" F4 1/4"
Weight in g
300 320 300 320 300 320 300 320
Part No.
212218 212225 212232 212249 219910 226901 226918 226925
120
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
www.condor-cpc.com
Page 3.11
Description
Unloader valves With screw connection for 6 mm plastic or copper discharge tubes With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or discharge copper tubes 90 with screw connection for 1/4" mm plastic or discharge copper tubes
Weight in g
25 25 15 15 15
Part No.
200666 200680 200697 200703 200710
90 with quick-connect for 6 mm plastic discharge tubes Unloader valves for difficult motor starting conditions With quick-connect for 6 mm plastic discharge tubes 90 with screw connection for 6 mm plastic or copper discharge tubes 90 with screw connection for 1/4" mm plastic or copper discharge tubes 90 with quick-connect for 6 mm plastic discharge tubes Cable glands Grommet With strain relief With strain relief and cable support Cover Cover without On/Off lever (Neural version without marking) Cover with On/Off lever for manual On/Off (neutral version, without marking)
25 15 15 15
6 12 12
H 21
(Cover MDR 21) H 21-EA (Cover MDR 21+EA)
40 40
229452 217503
EV 2
EV 2S
AEV 2S
EV 2W / EV 2Wi
EV 2WS
AEV 2WS
WN
PG 13,5 Z-21
PG 13,5 ZK-21
Page 3.12
www.condor-cpc.com
EV 2
EV 2S
AEV 2S
Pressure Diagrams
www.condor-cpc.com
Page 3.13
3-phase Switching capacity 7.5 (11) kW Available with overload relay Max. cut-out pressure 35 bar 3-pole (N.C.) Acc. to EN 60947 UL / CSA-approval
Flange
G 1/2" G 1/2" G 1/4" F4 1/4" F4 1/2" F4 3/8" G 1/2" G 1/4" F4 1/4" F4 1/2" F4 3/8" G 1/2" F4 1/2" G 1/2" F4 1/2" G 1/2" G 1/2" G 1/4" F4 1/4" F4 1/2" F4 3/8" G 1/2" G 1/4" F4 1/4" F4 1/2" F4 3/8" G 1/2" F4 1/2" G 1/2" F4 1/2"
Weight in g
610 610 610 640 640 640 610 610 640 640 640 610 640 610 640 590 590 590 620 620 620 590 590 620 620 620 590 620 590 620
Part No.
212256 212263 212270 212287 212294 212300 212317 212324 212313 212348 212355 212362 212379 229711 229728 226932 226949 226956 226963 226970 226987 226994 227007 227014 227021 227038 227045 227052 229698 229704
Page 3.14
www.condor-cpc.com
Flange
G 1/2" G 1/2" G 1/2+1/4" G 1/2" G 1/2+1/4" G 1/2" G 1/2+1/4" G 1/2" G 1/2+1/4"
Weight in g
770 770 810 800 850 770 810 800 800
Part No.
229674 227595 227601 227632 227649 227618 227625 227656 227663
6 / 4 mm
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
www.condor-cpc.com
Page 3.15
MDR 3
MDR 3 EA 3 R 3 RA 3
MDR 3 EA 3 R 3 RU 3
MDR 3 EA 3 RA 3
MDR 3 EA 3 RU 3
MDR 3 EA 3 R 3
Description
Hourmeter and Cover for MDR-3 Hourmeter and Cover for MDR-3 Hourmeter and Cover for MDR-3+EA Hourmeter and Cover for MDR-3+EA
Voltage
230 V / 50 Hz 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz
Packing (units)
1 1 1 1
Part No.
237297 237303 237310 237327
Page 3.16
www.condor-cpc.com
Description
Unloader valves With screw connection for 6 mm plastic or copper discharge tubes With screw connection for 1/4 plastic or copper discharge tubes With quick-connect for 6 mm plastic discharge tubes 90 unloader valve with screw connection for 6 mm plastic or copper discharge tubes 90 unloader valve with screw connection for 1/4 plastic or copper discharge tubes 90 unloader valve with quick-connect for 6 mm plastic discharge tubes With screw connection for 6 mm plastic or copper discharge tubes Delayed unloader valves With screw connection for 6 mm plastic or copper discharge tubes With quick-connect for 6 mm plastic discharge tubes 90 unloader valve with screw connection for 6 mm plastic or copper discharge tubes 90 unloader valve with screw connection for 1/4 plastic or copper discharge tubes 90 unloader valve with quick-connect for 6 mm plastic discharge tubes Cable glands With strain relief (for additional wiring) Grommet Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Mounting bracket Cover Cover without rotary knob (Neutral version, without marking) Cover with rotary knob for manual On/Off (Neutral version, without marking)
Weight in g
25 25 25 18 18 10 30
Part No.
201045 201052 201069 201076 201083 201090 201229
25 25 18 18 10
12 6 6 12 12 12 6 12 12 12 6 12 12 18 65
201373 201243 201250 201267 201274 201281 201298 201304 201311 201328 201335 201342 201359 201366 230021
100 100
229490 230007
SK 3 SK 3-S SK R3/ 1,0 SK R3/ 1,6 SK R3/ 2,5 SK R3/ 4,0 SK R3/ 6,3 SK R3/ 10,0 SK R3/ 16,0 SK R3/ 20,0 SK R3/ 24,0 SK R3/ 30/2
Thermal, 3-pole overload relay Arc-chamber without lock mechanism (supplied as standard with MDR 3...) SK 3-S Arc-chamber with lock mechanism (supplied as standard with MDR 3...+EA) 0.63 1.00 A 1.00 1.60 A 1.60 2.50 A 2.50 4.00 A 4.00 6.30 A 6.30 10.00 A 10.00 16.00 A 16.00 20.00 A 20.00 24.00 A 22.00 30.00 A, 2 pole Undervoltage and shunt releases Undervoltage release 24 V, 50 Hz Undervoltage release 230 V, 50 Hz Undervoltage release 400 V, 50 Hz Shunt release 24 V, 50 Hz Shunt release 110 V, 50 Hz Shunt release 230 V, 50 Hz Shunt release 240 V, 60 Hz Shunt release 400 V, 50 Hz Shunt release 480 V, 60 Hz
90 110 145 145 145 145 145 145 145 145 145 145
201380 201397 201403 201410 201427 201434 201441 201458 201465 201472 201489 201496
RU 3/24-50 RU 3/230-50 RU 3/400-50 RA 3/24-50 RA 3/110-50 RA 3/230-50 RA 3/240-60 RA 3/400-50 RA 3/480-60 *up to 16 bar
www.condor-cpc.com
Page 3.17
EV 3 / EV 3i
EV 3S
AEV 3S
AEV 3
EV 3L
EV 3W / EV 3Wi
EV 3WS
AEV 3WS
WN
PG .. G
PG .. V
PG .. Z
PG .. ZK
MW 3
SK 3
SK 3-S
SK R3 / .. Pg 9 Z
RU ..
RA ..
Page 3.18
www.condor-cpc.com
EV 3 / EV 3i
EV 3S
AEV 3S
AEV 3
EV 3L
www.condor-cpc.com
Page 3.19
Page 3.20
www.condor-cpc.com
Flange
G 1/4" G 1/2" G 1/2" + 1/4 G 1/4" G 1/2" G 1/2" + 1/4 G 1/4" G 1/2" G 1/2" + 1/4 G 1/4" G 1/2" G 1/2" + 1/4 G 1/4" G 1/2" G 1/2" + 1/4 G 1/4" G 1/2" G 1/2" + 1/4
Weight in g
420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420
Part No.
212584 212591 212607 212614 212621 212638 212645 212652 212669 220084 220077 220121 204251 206194 227069 204244 220107 227076
Flange
1/2" 1/4" 1/2"
Weight in g
420 420 420
Part No.
212737 212744 212751
MDR-4 DAA BFDA 040A060 XAA XXX MDR-4 DBA BFDA 040A060 XAA XXX MDR-4 GAA BFDA 090A110 XAA XXX Unloader valves and cable glands for retrofitting see Accessories!
www.condor-cpc.com
Page 3.21
Flange
1/2" 1/2" 1/2"
Weight in g
420 420 420
Part No.
212706 212713 212720
> 5 x 10
120
2.5 / 2.5mm
120
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
Page 3.22
www.condor-cpc.com
Dimensions MDR 4
MDR 4 S
MDR 4 SD
MDR 4 SU
Accessories MDR 4
Order reference
EV 4 EV 4S EV 4W EV 4Wi EV 4WS
Description
Unloader valves With screw connection for 6 mm plastic or copper discharge tubes With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or discharge copper tubes 90 with screw connection for 1/4" mm plastic or discharge copper tubes
Weight in g
25 25 15 15 15
Part No
201601 201625 255055 255062 201656
90 with quick-connect for 6 mm plastic discharge tubes Unloader valves for difficult motor starting conditions With quick-connect for 6 mm plastic discharge tubes 90 with screw connection for 6 mm plastic or copper discharge tubes 90 with screw connection for 1/4" mm plastic or copper discharge tubes 90 with quick-connect for 6 mm plastic discharge tubes Cable glands Grommet Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Conduits for mounting of cable glands (Inner thread) Cable gland complete With strain relief With strain relief and cable support Mounting bracket Cover Cover without rotary knob (Neutral version, without marking) Cover with rotary knob for manual On/Off (Neutral version, without marking) Cover without rotary knob for MDR 4 SD (transparent)
25 15 15 15
6 6 12 12 12 6 12 12 12 65
200888 200895 200901 200925 200918 200963 200932 200956 200949 230021
H4
(Cover MDR 4S)
70 70 70
H4S+EA
(Cover MDR 4S+EA)
H4SD
(Cover MDR 4SD)
www.condor-cpc.com
Page 3.23
EV 4
EV 4S
AEV 4S
EV 2W / EV 4Wi
EV 4WS
AEV 4WS
MW 4
WN
PG .. G
PG .. V
PG .. Z
PG .. ZK
EV 4 S
AEV 4 S
www.condor-cpc.com
Page 3.25
ON / OFF buttons
K* K* K* K* K* K* K* K*
Flange
G 1/2" G 1/2" G 1/2 + 1/4" G 1/2 + 1/4" G 1/2" G 1/2" G 1/2 + 1/4" G 1/2 + 1/4" G 1/2" G 1/2" G 1/2 + 1/4" G 1/2 + 1/4" G 1/2" G 1/2" G 1/2 + 1/4" G 1/2 + 1/4"
Weight in g
820 860 860 900 820 860 860 900 820 860 860 900 820 860 860 900
Part No.
212850 212867 212874 212881 212898 212904 212911 212928 212935 212942 212959 212966 212973 212980 212997 213000
* For these switches, a thermal, 3-pole overload relay has to be ordered separately, otherwise the ON/OFF switching mechanism will not function. Unloader valves and cable glands for retrofitting see Accessories!
Technical Data
Technical Data MDR 5 acc. to EN 60947
Rated insulation voltage Ui Motor switching capacity (AC 3) Ue=240 V (1~) Motor switching capacity (AC 3) Ue=230 V (3~) Motor switching capacity (AC 3) Ue=400 V (3~) Motor switching capacity (AC 3) Ue=500 V (1~) Electrical life (AC 3) Cycles Mechanical life Cycles Max. electrical cycles Cycles/h Max. mechanical cycles Cycles/h Rated operational current Ie at 240 V AC 500 V 2.5 kW 4.0 kW 5.5 kW 4.0 kW > 1 x 10 > 5 x 10
5
4 / 4mm
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
Page 3.26
www.condor-cpc.com
Dimensions MDR 5
MDR 5
MDR 5K R5
Accessories MDR 5
Order reference
EV 5 EV 5i EV 5E EV 5Ei
Description
Unloader valves With screw connection for 6 mm plastic or copper discharge tubes, screw connection for vent port With screw connection for 1/4" plastic or copper discharge tubes With screw connection for 6 mm plastic or copper discharge tubes With screw connection for 1/4" plastic or copper discharge tubes Delayed unloader valves With screw connection for 6 mm plastic or copper discharge tubes With screw connection for 1/4" plastic or copper discharge tubes Cable glands Grommet Cable glands complete With strain relief With strain relief and cable support Reduced to PG 13.5 with strain relief Reduced to PG 13.5 with strain relief and cable support Reduced to PG 11 Mounting bracket Cover Cover without push-buttons Cover with On/Off push-buttons (Only functions together with the thermal R5 overload relay) Thermal, 3-pole overload relay 0.86 1.50 A 1.50 2.45 A 2.40 4.20 A 4.00 7.00 A 6.10 10.3 A 9.00 14.0 A 11.0 18.0 A
Weight in g
30 30 25 25
Part No.
201878 201885 201892 201908
AEV 5 AEV 5i
25 25
201939 201946
6 12 12 12 12 12 12 120
130 150
230052 217527
www.condor-cpc.com
Page 3.27
EV 5, EV 5i
EV 5E / EV 5 Ei
AEV 5 / AEV 5i
WN 5
PG 16 V-5
PG 16 Z-5
PG 16 ZK-5
PG 16/11 V-5
Accessories, Miscellaneous
MW 5
H5
H5-K
R 5/ ..
Dimensions, Accessories
EV 5, EV 5i
EV 5E / EV 5 Ei
AEV 5 / AEV 5i
Page 3.28
www.condor-cpc.com
www.condor-cpc.com
Page 3.29
Page 3.30
www.condor-cpc.com
MDR - F
Pressure ranges up to 250 bar Ample wiring room Simple calibration High repeatability 1 SPDT Acc. to EN 60947 Ample variety of models Pressure ranges up to 16 bar Transparent cover 1 N.O. + 1 N.C. Acc. to EN 60947
Page 4.02
MDR 43
4.11
MDR 53
Pressure ranges up to 16 bar Ample wiring room High switching accuracy 1 PSDT Acc. to EN 60947 UL / CSA-approval Pressure ranges up to 40 bar Ample wiring room Simple calibration 2 SPDT's Acc. to EN 60947 Insulate and die-cast Pressure ranges up to 31 bar Simple calibration 1 SPDT Acc. to EN 60947 UL / CSA-approval Also for vacuum applications
4.13
FF 142
4.16
PS 1
4.20
www.condor-cpc.com
Page 4.01
Application The Condor pressure switch series MDR-F can be universally used and are suitable for: - Monitoring and controlling the pressure of liquids or gaseous media in pipelines, tanks, vats, pressure vessels and apparatus. - Tasks in process control, cooling, pneumatics and hydraulics. - Pressure monitoring of cooling circuits and lubrication systems on various types of machinery. - Automatic switching of pump and compressor motors for supplying water to dwellings, booster pumps, fire-fighting equipment and on compressed air systems.
When the pressure reaches the upper switching point, the micro switch contacts change position. In normal cases e.g. a connected motor is switched off (up to 550 watts direct or using additional switches like a contactor etc.). Should the pressure fall below the lower switch point, then the micro switch contact returns to its default position and the motor is switched on. The upper and lower switching points can be set independently using a screw driver. Both switching points can be read off the scale. Pressure connection, pressure sensing element and electrical connections are all fitted on to a diecast aluminum base. The sealable transparent, polycarbonate cover protects the scales and switch against environmental effects. Standard scope of delivery: rubber grommets MDR-F..H Die-cast aluminum flange MDR-F..Y Plastic flange (in particular for use in water technology applications)
Mode of operation: The pressure of the monitored medium operates against a diaphragm, bellows or a plunger all of which have different media resistance. Switching operation is carried out with the use of a micro switch ensuring flutter-free switching.
Besides the standard types with Perbunan diaphragms, the following new types are available: - Pressure switch with stainless steel pressure sensing element e.g. for liquid fuels, oils up to 200C etc. - High pressure switch with plastic plunger press. sensing element with stainless steel connection up to 250 bar - Pressure switch with manual reset function and die-cast aluminum flange for oil, water and air etc. - Pressure switch with Viton diaphragm and die-cast aluminum flange for increased media resistance The MDR-F pressure switch program is being constantly expanded. Along with the VdS approval, the following approvals are being presently processed: Atex, Germanischer Lloyd etc. The VdS version will be available no later than beginning 2008.
Page 4.02
www.condor-cpc.com
Matchcode
Part No.
MDR-F 2 HAA AAA A 005A015 MDR-F 2 HAA ABA A 005A015 MDR-F 4 HAA AAA A 010A030 MDR-F 4 HAA ABA A 010A030 MDR-F 8 HAA AAA A 020A060 MDR-F 8 HAA ABA A 020A060 MDR-F 10 HAA AAA A 040A050 MDR-F 10 HAA ABA A 040A050 MDR-F 16 HAA AAA A 040A120 MDR-F 16 HAA ABA A 040A120 MDR-F 32 HAA AAA A 100A200 MDR-F 32 HAA ABA A 100A200
252511 252528 252535 252542 252559 252566 252573 252580 252597 252603 252610 252627
Matchcode
Part No.
MDR-F 2 HAA SAA A 005A015 MDR-F 2 HAA SBA A 005A015 MDR-F 4 HAA SAA A 010A030 MDR-F 4 HAA SBA A 010A030 MDR-F 8 HAA SAA A 020A060 MDR-F 8 HAA SBA A 020A060 MDR-F 10 HAA SAA A 040A050 MDR-F 10 HAA SBA A 040A050 MDR-F 16 HAA SAA A 040A120 MDR-F 16 HAA SBA A 040A120 MDR-F 32 HAA SAA A 100A200 MDR-F 32 HAA SBA A 100A200
253501 253518 253525 253532 253549 253556 253563 253570 253587 253594 253600 253617
Matchcode
Part No.
MDR-F 2 YAA AAA A 005A015 MDR-F 2 YAA ABA A 005A015 MDR-F 4 YAA AAA A 010A030 MDR-F 4 YAA ABA A 010A030 MDR-F 8 YAA AAA A 020A060 MDR-F 8 YAA ABA A 020A060 MDR-F 10 YAA AAA A 040A050 MDR-F 10 YAA ABA A 040A050 MDR-F 16 YAA AAA A 040A120 MDR-F 16 YAA ABA A 040A120
252634 252641 252658 252665 252672 252689 252696 252702 252719 252726
www.condor-cpc.com
Page 4.03
Matchcode
Part No.
MDR-F 2 YAA SAA A 005A015 MDR-F 2 YAA SBA A 005A015 MDR-F 4 YAA SAA A 010A030 MDR-F 4 YAA SBA A 010A030 MDR-F 8 YAA SAA A 020A060 MDR-F 8 YAA SBA A 020A060 MDR-F 10 YAA SAA A 040A050 MDR-F 10 YAA SBA A 040A050 MDR-F 16 YAA SAA A 040A120 MDR-F 16 YAA SBA A 040A120
253624 253631 253648 253655 253662 253679 253686 253693 253709 253716
Matchcode
Part No.
MDR-F 12 HEC AAA A 060A070 MDR-F 12 HEC ABA A 060A070 MDR-F 30 HEC AAA A 160A200 MDR-F 30 HEC ABA A 160A200
Matchcode
Part No.
MDR-F 12 HEC SAA A 060A070 MDR-F 12 HEC SBA A 060A070 MDR-F 30 HEC SAA A 160A200 MDR-F 30 HEC SBA A 160A200
Matchcode
Part No.
MDR-F 60 HHC AAA A 200A400 MDR-F 60 HHC ABA A 200A400 MDR-F 120 HHC AAA A 200A800 MDR-F 120 HHC ABA A 200A800 MDR-F 250 HHC AAA A 100F200 MDR-F 250 HHC ABA A 100F200
Page 4.04
www.condor-cpc.com
Matchcode
Part No.
MDR-F 60 HHC SAA A 200A400 MDR-F 60 HHC SBA A 200A400 MDR-F 120 HHC SAA A 200A800 MDR-F 120 HHC SBA A 200A800 MDR-F 250 HHC SAA A 100F200 MDR-F 250 HHC SBA A 100F200
MDR-F .. Htro (SPDT with manual reset as run-dry protection) The manual reset button must be held when the pressure rises beyond the switching point to be monitored or pressed once at the current pressure. When the pressure falls, contact 11-12 closes and opens contact 11-14 when the monitored pressure point is reached. When the pressure rises above the adjusted value, contact 11-12 opens and closes contact 11-14 again automatically. Industrial cage clamp version
Order reference
MDR-F 2Hmax MDR-F 4Hmax MDR-F 8Hmax MDR-F 10Hmax MDR-F 16Hmax MDR-F 32Hmax MDR-F 2Hmin MDR-F 4Hmin MDR-F 8Hmin MDR-F 10Hmin MDR-F 16Hmin MDR-F 32Hmin MDR-F 2Htro MDR-F 4Htro MDR-F 8Htro MDR-F 10Htro MDR-F 16Htro MDR-F 32Htro
Matchcode
Part No.
MDR-F 2 HAA AAH A 005A015 MDR-F 4 HAA AAH A 010A030 MDR-F 8 HAA AAH A 020A060 MDR-F 10 HAA AAH A 040A050 MDR-F 16 HAA AAH A 040A120 MDR-F 32 HAA AAH A 100A200 MDR-F 2 HAA AAL A 005A015 MDR-F 4 HAA AAL A 010A030 MDR-F 8 HAA AAL A 020A060 MDR-F 10 HAA AAL A 040A050 MDR-F 16 HAA AAL A 040A120 MDR-F 32 HAA AAL A 100A200 MDR-F 2 HAA AAG A 005A015 MDR-F 4 HAA AAG A 010A030 MDR-F 8 HAA AAG A 020A060 MDR-F 10 HAA AAG A 040A050 MDR-F 16 HAA AAG A 040A120 MDR-F 32 HAA AAG A 100A200
253075 253082 253099 253105 253112 253129 253136 253143 253150 253167 253174 253181 253433 253440 253457 253464 253471 253488
www.condor-cpc.com
Page 4.05
Matchcode
Part No.
MDR-F 2 HAA SAH A 005A015 MDR-F 4 HAA SAH A 010A030 MDR-F 8 HAA SAH A 020A060 MDR-F 10 HAA SAH A 040A050 MDR-F 16 HAA SAH A 040A120 MDR-F 32 HAA SAH A 100A200 MDR-F 2 HAA SAL A 005A015 MDR-F 4 HAA SAL A 010A030 MDR-F 8 HAA SAL A 020A060 MDR-F 10 HAA SAL A 040A050 MDR-F 16 HAA SAL A 040A120 MDR-F 32 HAA SAL A 100A200 MDR-F 2 HAA SAG A 005A015 MDR-F 4 HAA SAG A 010A030 MDR-F 8 HAA SAG A 020A060 MDR-F 10 HAA SAG A 040A050 MDR-F 16 HAA SAG A 040A120 MDR-F 32 HAA SAG A 100A200
254065 254072 254089 254096 254102 254119 254126 254133 254140 254157 254164 254171 254188 254195 254201 254218 254225 254232
Additional MDR-F pressure switch versions .. Reset function are available on request (e.g. as stainless steel bellows version, with gold-flashed contacts, as high pressure switch etc.).
Matchcode
Part No.
MDR-F 2 HAV AAA A 005A015 MDR-F 4 HAV AAA A 010A030 MDR-F 8 HAV AAA A 020A060 MDR-F 10 HAV AAA A 040A050 MDR-F 16 HAV AAA A 040A120 MDR-F 32 HAV AAA A 100A200
Matchcode
Part No.
MDR-F 2 HAV SAA A 005A015 MDR-F 4 HAV SAA A 010A030 MDR-F 8 HAV SAA A 020A060 MDR-F 10 HAV SAA A 040A050 MDR-F 16 HAV SAA A 040A120 MDR-F 32 HAV SAA A 100A200
Additional pressure switch versions MDR-F .. HV are available on request (e.g. as manual reset pressure switches, with gold-flashed contacts, with plastic flange etc.).
Page 4.06
www.condor-cpc.com
IP 65
- 20 C .. + 70 C 1.5 mm 2.5 mm
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
www.condor-cpc.com
Page 4.07
Dimensions MDR - F
For special applications e.g. VdS, individual circuits are possible due to the use of integrated PCB's (as default, contacts A and B are bridged)
Accessories MDR - F
Order reference
MDR-F M20 Cable glands Cable gland M20 Throttle MDR-F up to 32 bar MDR-F as of 32 bar Covers MDR-F Cover, transparent, Standard MDR-F Cover, transparent, for manual reset Reset push-button Reset push-buttons for mounting on cover R
Description
Weight in g
35
Part No.
254249
1 2
254256 254263
90 90
254270 254287
MDR-F RT-1
25
254294
Page 4.08
www.condor-cpc.com
www.condor-cpc.com
Page 4.09
Druckschalter MDR - F
Page 4.10
www.condor-cpc.com
Druckschalter MDR 43
Flange
G 1/2" G 1/4" G 1/2" G 1/4" G 1/2" G 1/4" G 1/2" G 1/4"
Weight in g
420 420 420 420 420 420 420 420
Part No.
212775 212782 212799 212805 212812 217829 217836 219843
Electrical life (AC 3) Cycles Mechanical life Cycles Max. electrical cycles Cycles/h Max. mechanical cycles Cycles/h Rated operational current Ie at 240 V AC Bursting strength Pz
resistant Acetylene, Butane, Natural gas, Petroleum, Vinegar 25 %, Glycerol, Carbon dioxide, Air, Propane, Sulphur dioxide, Silicon oil, Water, Distilled water, Hydrogen, Sea water A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
Description
Cable glands Grommet Conduits for mounting cable glands (inner thread) Cable glands complete With strain relief With strain relief and cable support Conduits for mounting cable glands (inner thread) Cable glands complete With strain relief With strain relief and cable support Mounting bracket Cover Cover (Transparent)
Weight in g
6 6 12 12 12 6 12 12 12 65
Part No.
200888 200895 200901 200925 200918 200963 200932 200956 200949 230021
H43
(Cover MDR 43)
70
230038
MW 4
WN
PG .. G
PG .. V
PG .. Z
PG .. ZK
Page 4.12
www.condor-cpc.com
ON / OFF
-
Flange
G 1/2" G 1/2" G 1/2" G 1/2" G 1/2"
Weight in g
740 780 780 740 740
Part No
213079 216919 213086 213130 213147
* xxx = Cut-out pressure is preset, cut-in pressure is the tightest possible pressure differential. ** xxx = Cut-out pressure is preset, cut-in pressure is the tightest possible pressure differential and pressure-resistant up to 25 bar, SOType. A screw plug is also supplied. Cable glands for retrofit assembly to be ordered separately see Accessories!
Electrical life (AC 3) Cycles Mechanical life Cycles Max. electrical cycles Cycles/h Max. mechanical cycles Cycles/h Rated operating current Ie Bursting strength Pz Rated operating current Ie at 240 V AC
10 A > 40 bar
- 5...+ 80 C
Acetylene, Butane, Natural gas, Petroleum, Vinegar 25 %, Glycerol, Carbon dioxide, Air, Propane, Sulphur dioxide, Silicon oil, Water, Distilled water, Hydrogen, Sea water
resistance
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
www.condor-cpc.com
Page 4.13
Description
Cable glands Grommet Cable glands, complete With strain relief With strain relief and cable support Reduced to PG 13,5 with strain relief Reduced to PG 13,5 with strain relief and cable support Reduced to PG 11 Mounting bracket Cover Cover without On/Off push-buttons
Weight in g
6 12 12 12 12 12 12 120
Part No.
201953 201960 201977 201984 202004 202011 201991 230045
H5 (Cover MDR 5)
130
230052
WN 5
PG 16 V-5
PG 16 Z-5
PG 16 ZK-5
PG 16/11 V-5
MW 5
H5
Page 4.14
www.condor-cpc.com
www.condor-cpc.com
Page 4.15
Applications The FF 142 Series is a pressure switch which has been standardized in a wide variety of industrial, commercial and sea-going applications to monitor or control the pressure of liquid or gaseous media: - Pipelines - Containers - Pressure vessels - Apparatus - Process technology - Pneumatics and hydraulics - Refrigeration and heating plants - Lubrication systems - Pump motors for water supply to dwellings
Function description Turning the setting knob Pmax. changes both the upper and the lower switch points. By turning the differential spindle Dp only, the lower switch point is adjusted, while the upper setting remains unchanged.
Construction The standard FF 142 series are fitted in insulation enclosures, made of ABS. Large clear scales ease exact adjustment of upper switch point and switching differential. They are marked both in bar and in psi units. Scales are connected to the frame of the device and remain in place, when the cover is removed. Ample wiring room simplifies wiring.
Page 4.16
www.condor-cpc.com
www.condor-cpc.com
Page 4.17
A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
Description
Weight in g
4
Part No
1090401021
Page 4.18
www.condor-cpc.com
www.condor-cpc.com
Page 4.19
Pressure ranges up to 31 bar Simple calibration 1 SPDT Acc. to EN 60947 UL / CSA-approval Also for vacuum applications
Features
Tight adjustable differentials (depending on type) Range and differential adjustments in bar und psi Range and differential adjustments are
Wiring bridge for reduced installation costs Different mounting plates Special approvals
Description The PS 1 is an adjustable pressure switch for use in refrigeration units and heat pumps. These pressure switches serve to fulfil many different control purposes in the units (e.g. Pump-Down) and as safety devices, e.g. safety pressure limiter against rising pressure. While control functions are usually intended for mostly acceptable or optimized unit operations, safety functions are generally absolutely required by national law. Following national and international standards therefore, facilitates the abidance of legal requirements. Standardization is within the EC a continuous process. The most important standards for safety and environmental requirements for refrigeration units are EN 378 und DIN 8901. The PS1 series contains pressure switches which have been built and approved according to DIN 32733. Therefore these pressure switches can be used to fulfil the requirements of DIN 8901and EN 378.
individually sealable Change over contacts with high ratings Cover with captive screw Robust, finger protected terminals with self retaining screws cable centering Test lever with front operation for maintenance and plant filling Versions with automatic manual reset Convertible reset automatic / manual
Special versions Alternative pressure connectors including 6mm ODF Golf-flashed contacts for circuits with low contact current loads (PLC's)
Type overview PS 1
Order reference
PS 1 - A1R PS 1 A2R PS 1 A3R PS 1 A4R PS 1 A5R PS 1 A6R Upper switch point (bar) - 0.75 .. 3 - 0.8 .. 1.5 - 0.5 .. 7 1 .. 20 6 .. 31 4 .. 12 Pressure diff. (bar) 0.25 .. 2 0.2 .. 1 0.5 .. 5 1 .. 10 2 .. 15 0.5 .. 7 Lower switch point (bar) - 0.9 - 1.0 - 0.9 0.3 3.0 0.1 Factory setting (bar) 0.5 / 1 0.5 / 1 3.5 / 4.5 8 / 10 16 / 20 6/7 Leakage test pressure (bar) 13 13 13 23 36 16 Pressure connection G outer G outer G outer G outer G outer G outer Part No.
Page 4.20
www.condor-cpc.com
Technical Data PS 1
Technical Data PS 1 acc. to EN 60947 UL/CSA
Rated operational current Ie AC 1 Ue=230 V AC Rated operational current Ie AC 15 Ue=230 V AC Rated operational current Ie DC 13 Ue=230 V DC Motor rating (FLA) Locked rotor (LRA) / startup (AC3) 24 A / 230 V AC 10 A / 230 V AC 0.1 A / 230 V AC 3 A / 24 V AC 6 A / 12 V AC 24 A / 230 V AC 144 A / 230 V A
Vibration resistance
4 g 10...1000 Hz
** Switch mounted flush against wall
Brass/Bronze Copper/Bronze
resistant Acetone, Acetylene, Gasoline, Benzene, Butane, Butyl alcohol, Diesel, Natural gas, Ethylene glycol, Petroleum, Carbon dioxide, Carbonic acid, Air, Mineral oils, Vegetable oil, Propane, Oxygen, Sulphur dioxide, Water, Hydrogen A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11
www.condor-cpc.com
Page 4.21
Pressure Diagrams PS 1
Page 4.22
www.condor-cpc.com
Level Monitoring
Overview
Page 5.02
PSN
Float switches which switch On and Off depending on the cable length
5.06
ENP
Electronic pump control Single and dual pump control with monitoring functions
5.10
ENR
5,12
HRH - 2
5.14
ENS
5.16
www.condor-cpc.com
Page 5.01
For level measurement there are different methods that can be used
1. Level measurement method using
CPSmodular
float switches
2. Impact pressure
Lid
Backlog vane
Application e.g. using: Electronic level transducer ENI 2 and Closed wet bell GGL
In this application the level change is transmitted via a pneumatic tube to the sensor and evaluated. The two types of systems closed and open - are described in more detail below:
Closed system For the use of a closed system, a completely sealed measuring system is an absolute necessity. A leak in the system, through which air can diffuse, leads to a drop in pressure and subsequently a malfunction of the device. The sealed bell GGL-8 (see accessories section) placed into the medium seals the measurement system at the "measuring point".
Application e.g. using: Level control ENP and Open wet bell
OGL-GU
www.condor-cpc.com
Page 5.03
In this application, the aid of a small compressor is necessary, whereby in either continuous or periodic operation, air is fed into the system. The pressure within the measuring system (pneumatic tube) therefore remains constant. Only when a change in the level occurs is the pressure altered in the measuring system, which is subsequently detected by the evaluating unit.
Application e.g. using: Electronic level relay ENR2 T-connector for pneumatic tube Small air compressor Rena Open wet bell OGL
Air 100
Application e.g. using: Electronic level relay HRH-2 and Electrodes TEL
- ..
Page 5.04
www.condor-cpc.com
In this application, a level sensor is lowered into the medium within a sealed enclosure, whereby ceramic or piezoresistive sensors are used. The filling level pressure then acts directly on the ceramic or piezoresistive sensor and the subsequent value is then transmitted as a 4-20 mA signal via the connecting lead.
Application e.g. using: Electronic pump control CPS Level sensor ENS
modular 2 and
www.condor-cpc.com
Page 5.05
PSN-F
Float switches for filling. On reaching the lower switching threshold the switching mechanism activates the pump. On reaching the upper switching threshold the pump is switched off.
PSN-X
Float switches for filling and emptying
PSN-.. + ST
Float switch with plug and socket for pump connection.
PSN-O DB
Float switches for emptying with integrated cable breakage and short-circuit monitoring, with gold flashed contacts.
PSN-X-SP
Float switches for filling and emptying for PLC application and for intrinsically safe circuits, with gold flashed contacts.
Neoprene Insulated Lead Highly flexible lead acc. to VDE 282 Part 4 resp. HD 22.4 S3 guarantees a long service life Protective Conductor Connection acc. to VDE 0631 Part 1 protection class 1 resp. EN 60730-1 A metal shield connected to the protective conductor of the lead ensures additional protection against electrical shock.
Perfect Casing The inner chamber with the switch mechanism and lead are seamlessly enclosed by isolating polypropylene.
Contact Rating Motors with a switching capaacity of up to 1.1 kW (at 250 V~) may be switched directly. High Quality HR-Foam Floating Body Physical properties and chemical resistance of the polypropylene body are extraordinarily high, so that damages due to mechanical impact or chemical influence may be ruled out. KLS Ball Guiding System The new ball guiding system KLS ensures an even higher switching accuracy within the tolerance range.
Page 5.06
www.condor-cpc.com
Float switch
PSN- ..
PSN-F 3 m PSN-F 5 m PSN-F 10 m PSN-F 15 m PSN-F 20 m PSN-X 3 m PSN-X 5 m PSN-X 10 m PSN-X 15 m PSN-X 20 m PSN-O + ST 5 m PSN-O + ST 10 m PSN-F + ST 5 m PSN-F + ST 10 m PSN-O DB 5 m PSN-O DB 10 m
for filling
Float switch
PSN- ..+ ST
for emptying with integrated cable breakage and short-circuit monitoring, with gold flashed contacts for filling and emptying for PLC application and for intrinsically safe circuits, with gold flashed contacts, exportversion without protective conductor, 1 SPDT
5m 10 m 15 m 20 m 30 m 40 m
Weight BG - PS
Cable support K - PS
K - PS
www.condor-cpc.com
Page 5.07
60 C 85 C IP 68 3 x 1 mm H 07 RN-F
60 C 85 C IP 68 3 x 1 mm H 07 RN-F
Limited resistance
Acetic acid (hydrous 10%), Nitric acid (hydrous 10%), Chlorinated water, Hydrogen peroxide
Types
Page 5.08
www.condor-cpc.com
The conditions can be evaluated with any PLC or with special controls featuring an analogue input.
Dimensions
www.condor-cpc.com
Page 5.09
Electronic pump control for filling and emptying a tank with integrated relative pressure transducer for panel board mounting, connection for pneumatic tube, four adjustable switching points, 3 relay outputs, staging and sequencing control, isolating transformer acc. to VDE 0550. Function: The device analyses the pressure applied to the sensor. Two pumps for emptying a tank are connected to terminals 11/14 and 21/24 an alarm can be connected to terminals 31/34. All levels are adjustable. The LED's illuminate when the pumps, or the alarm are switched on. The relays are activated. The tripping delay for the alarm is fixed, preset value.
Accessories ENP
Order reference
KL-S
Description
Jack 2.5 mm for analogue output connection (cable length 5 m)
Part No.
3709400
Enclosure
RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
Analogue output
Analogue voltage signal max. 5 mA short-circuit proof 0 - 10 V
Page 5.10
www.condor-cpc.com
Terminal connection
Terminal connection
Analogue output
Analogue output
0 10 V B A1 A2 = Operating voltage UB B = Quick-connect for pneumatic tube 11, 12, 14 = SPDT contacts Pump 1 31, 34 = Alarm contact +, = Analogue output 0 10 V Bridge between contacts 11 - 21 Bridge between contacts 14 - 24 B
0 10 V
A1 A2 = Operating voltage UB B = Quick-connect for pneumatic tube 11, 12, 14 = SPDT contacts Pump 1 21, 24 = Contacts Pump 2 31, 34 = Alarm contact +, = Analogue output 0 10 V
www.condor-cpc.com
Page 5.11
0.01 m
3700300
Accessories ENR
Order reference
KL-S
Description
Jack 2.5 mm for analogue output connection (cable length 5 m)
Part No.
3709400
Enclosure
RABS flameproof, ULapproved
snap on 35 mm DIN-rail connector acc. to EN 50 035
Analogue output
Analogue voltage signal max. 5 mA short-circuit proof 0 - 10 V
Page 5.12
www.condor-cpc.com
Dimensions ENR
www.condor-cpc.com
Page 5.13
Time reaction
< 400 ms
Part No.
3702500
Description
Application
Part No.
236467 3702100 3702110 3702120 3702200
3702210 3702220
Page 5.14
www.condor-cpc.com
Output contacts
Series voltage acc. to VDE 0660 and VDE 0110 Group C Maximum continuous current per contact Maximum switching capacity per contact Mechanical life Cycles Electrical life (max load) Cycles 250 V-AC 6 A-AC 4.000 VA (AC) 384 W (DC) 7 approx. 3 x 10 approx. 0,7 x 10
5
Electrode TEL-05
www.condor-cpc.com
Page 5.15
With ceramic measuring cell, shielded cable and a specially designed stainless steel enclosure, Condor offers a precision level sensor for all different types of applications, like e.g. wastewater. The sensor offers extremely high media resistance and the especially large membrane makes the sensor insensitive to pollution. The shielded cable protects the output signal (4 20 mA) against electromechanical influences. The ENS level sensor is also available with ATEX (explosive atmosphere) approval.
X X X X X X X X X X X X X
Accessories ENS
Description
Galvanized fixing clamp for level sensor Stainless steel fixing clamp for level sensor Protective cap for level sensor as replacement Cable extension, max. 200 m possible Part No. 290223 242227 242735 242734
Temperature range:
EX-protection:
Page 5.16
www.condor-cpc.com
Dimensions ENS
Application example: Level sensor ENS Monitors e.g. Wastewater/Water level in a pump shaft
www.condor-cpc.com
Page 5.17
Page 5.18
www.condor-cpc.com
Motor Technology
Overview
OKE2
Manual motor starters with push-button 3-pole operation Thermal trip Setting range 1.0 25.0 A; 500 V AC Switching capacity 11 kW Switching operations 60/h Manual motor starters with push-button 3-pole operation Thermal/magnetic trip Setting range 1.0 25.0 A; 500 V AC Switching capacity 11 kW Switching operations 60/h Manual motor starters with push-button 3-polig Thermal/magnetic trip Thermal contacat Setting range 0.40 10.0 A; 230 V AC
Page 6.02
MKE2
6.02
TFE2
6.08
TFA2
Manual motor starters with push-button 3-pole operation Electronic release Thermal contact Setting range 0.10 25.0 A; 400 V AC
6.08
OKN
Manual motor starters with push-button 3-pole operation Thermal trip with phase drop protection Setting range 0.25 27.0 A; 500 V AC Switching capacity 7.5 kW Switching operations 30/h Star/Delta starter With manual motor starter Thermal/magnetic trip Switching capacity 5,5 / 7,5 and 11 kW
6.10
C-SDU
6.13
www.condor-cpc.com
Page 6.01
Manual Motor Starter OKE2, 3-pole Thermal trip Setting range 1.0 25.0 A; 500 V AC Switching capacity 11 kW Switching operations 60/h Including PE/N bar (left side)
OKE2 1.6 OKE2 2.5 OKE2 4.0 OKE2 6.3 OKE2 10.0 OKE2 16.0 OKE2 25.0
202 721 202 738 202 745 202 752 202 769 202 776 202 783
Manual Motor Starter MKE2, 3-pole Thermal/magnetic trip Setting range 0.10 25.0 A; 500 V AC Switching capacity 11 kW Switching operations 60/h Including PE/N bar (left side)
MKE2 0.16 MKE2 0.5 MKE2 0.40 MKE2 0.63 MKE2 1.00 MKE2 1.60 MKE2 2.50 MKE2 4.00 MKE2 6.30 MKE2 10.0 MKE2 16.0 MKE2 25.0
202 158 202 165 202 172 202 189 202 196 202 202 202 219 202 226 202 233 202 240 202 257 202 264
Page 6.02
www.condor-cpc.com
Auxiliary contact (OKE2 / MKE2) Auxiliary current paths Rated insulation voltage IEC 947 Thermal current Ith2 Short-circuit protection back-up fuse gL MCB B 6 A
230 V 6A 10 A B6A
6A 4A
400 V AC 500 V AC may be used for low voltage and PLC inputs acc. to DIN 19240
3A 1A
Standards (OKE 2/MKE 2) The devices comply with the requirements of major international, European and national specifications
Degree of Protection acc. to DIN 40050 open type enclosed type * with cable end sleeve
Undervoltage release (OKE 2/MKE 2) Energizing voltage % von Uc De-energizing voltage % von Uc Relative Duty factor % von Uc Power consumption Closing Holding
85 35 .. 70 100
Shunt release (OKE 2/MKE 2) Energizing voltage % von Uc Power consumption Closing Holding
ca. 70
6.0 VA 3.0 VA
6.0 VA 3.0 VA
www.condor-cpc.com
Page 6.03
1.0 1.6 1.6 2.5 2.5 4.0 4.0 6.3 6.3 10.0 10.0 16.0 16.0 25.0
0.10 0.16 0.16 0.25 0.25 0.40 0.40 0.63 0.63 1.0 1.0 1.6 1.6 2.5 2.5 4.0 4.0 6.3 6.3 10.0 10.0 16.0 16.0 25.0
63 63 63 63
35 50 63 63 63
25 50 50 50 50
Protection of PVC-insulated cables against thermal overload due to short-circuit: According to VDE 0100 Parts 430 and 523, cables and wires have to be protected against overload and short-circuit. The table shows which cable cross-sections are protected against short circuit by the MKE 2.
Page 6.04
www.condor-cpc.com
Packing (units) 1 1 1
Part No.
Hi 10 Hi 01 Hi 11
AS 230-50 AS 400-50
1 1
60 60
1 1 1
60 60 60
A IP 55 B IP 55 C IP 54 G IP 65 E IP 54
1 1 1 1 1
202 554 202 561 202 585 202 578 202 622
NAK V AZ
1 1 1
55 40 25
Enclosure A
Enclosure G + MKE2
www.condor-cpc.com
Page 6.05
Enclosure A
Enclosure B
Enclosure C
Enclosure G
Page 6.06
www.condor-cpc.com
www.condor-cpc.com
Page 6.07
Motor starter for motors with integrated thermal contacts TFE Thermal/magnetic trip Thermal contact Single phase version 230 V (1~) Setting range 0.4 10.0 A; 230 V AC
TFE2 230 Hi 10 Hi 01 Hi 11 A IP 55
210 078 202 228 202 301 202 325 202 554
Motor starter for motors with integrated thermal contacts TFA Electronic trip Thermal contact 3-phase version 400 V (3~) Setting range 0.10 25.0 A; 400 V AC
TFA2 400 Hi 10 Hi 01 A IP 55
Page 6.08
www.condor-cpc.com
Enclosure A
TFA2 +
Enclosure A Enclosure A
www.condor-cpc.com
Page 6.09
Manual motor starter with rotary knob, 2/3-pole Thermal trip with phase-drop protection Setting range 0.25 27.0 A; 500 V AC Switching capacity 7.5 kW Switching operations 30/h
OKN 0.4 OKN 0.63 OKN 1.0 OKN 1.6 OKN 2.5 OKN 4.0 OKN 6.3 OKN 10.0 OKN 16.0 OKN 22.0 OKN 27.0 OKN 30.0 OKN 37.0
0.25 0.40 A 0.40 0.63 A 0.63 1.00 A 1.00 1.60 A 1.60 2.50 A 2.50 4.00 A 4.00 6.30 A 6.00 10.0 A 10.0 16.0 A 16.0 22.0 A 22.0 27.0 A 22.0 30.0 A (2-pole) 28.0 37.0 A (2-pole)
1 1 1 1 1 1 1 1 1 1 1 1 1
170 170 170 170 170 170 170 170 170 170 170 170 170
203 391 203 407 203 414 203 421 203 438 203 445 203 452 203 469 203 476 203 483 203 490 203 506 236 665
2 x M4* 100.000 30 2/3 37 A / 250 V 27 A / 500 V 37 A, 2-pol / 27 A, / 3-pol 22 37 A , 2-pol 0.25 27 A, 3-pol 2 / 11 1.8...3.2 W 10A
-25...+ 70 C -25...+ 60 C -25...+ 40 C yes IEC 68 T2-3, 2-30 Intensity 850C preferably vertical 3000 m 25 Hz b.+/- 1 mm Amplitude (2,5 g) 20 g (11 ms)
Numbers of ranges Current dissipation loss Main current paths at Ie max./Phase Trip class *not included
Page 6.10
www.condor-cpc.com
6 kA 3 kA 3 kA 1 kA
Standards (OKN) The devices comply with the requirements of major international, European and national specifications
7.5 kW 11.5 kW 15 kW
Accessories OKN
Order reference Description Enclosure-accessories Enclosure H, protection IP 41 Packing (units) 1 Weight in g 225 Part No
203 513
OKN +
Enclosure H Enclosure H
www.condor-cpc.com
Page 6.11
Enclosure H
Page 6.12
www.condor-cpc.com
Star/Delta starter
Star/Delta starters for motors
The Condor Pressure Control GmbH C-SDU Star/Delta starters offer, in due consideration of the relevant standards, the possibility of economically operating motors with a switching capacity greater than 4 kW using public mains networks. With this 2-stage starter the inrush current (Star circuit) is reduced by 1/3 of that to be expected when starting the motor directly. The torque is equally reduced during startup phase. During the start-up phase (1 32 seconds), a special change-over relay with a contact switching time of 40 ms, guarantees reliable change over from star to delta operation. During continuous operation, all motors connected to the Star/Delta starter are protected by a manual motor starter with thermal and magnetic trip.
C-SDU 7.5
4250
238 577
C-SDU 11.0
4400
238 584
www.condor-cpc.com
Page 6.13
Page 6.14
www.condor-cpc.com
Overview
Your Partners
Our Team introduces itself Page 7.02
7.03
Representatives Europe
7.04
Representatives Worldwide
7.06
Terms of Delivery
7.07
www.condor-cpc.com
Page 7.01
Your Partners
Sales Exports
Rudi Pfeiffer Sales Manager Export Phone: Telefax: Mobile: http:// e-Mail: Phone: Telefax: http:// e-Mail: Phone: Telefax: http:// e-Mail: +49 (0) 25 87 / 89 - 206 +49 (0) 25 87 / 89 - 44 - 206 +49 (0) 172 / 27 87 708 www.condor-cpc.com rpfeiffer@condor-cpc.com +49 (0) 25 87 / 89 - 154 +49 (0) 25 87 / 89 - 140 www.condor-cpc.com mborrmann@condor-cpc.com +49 (0) 25 87 / 89 - 153 +49 (0) 25 87 / 89 - 140 www.condor-cpc.com akasperczyk@condor-cpc.com
Monika Borrmann Sales Administration Export Annette Kasperczyk Sales Administration Export
Page 7.02
www.condor-cpc.com
Holding
Condor-Werke Gebr. Frede GmbH & Co. KG Warendorfer Strae 47 - 51 (Ortsteil Westkirchen) D-59320 Ennigerloh Phone: Telefax: http:// e-Mail: +49 (0) 25 87 / 89 - 0 +49 (0) 25 87 / 89 - 127 www.condor-werke.com info@condor-werke.com
Subsidiaries
Condor Pressure Control GmbH Warendorfer Strae 47 - 51 (Ortsteil Westkirchen) D-59320 Ennigerloh Condor Systems GmbH Warendorfer Strae 47 - 51 (Ortsteil Westkirchen) D-59320 Ennigerloh Condor USA, Inc. 8318 Pineville-Mathews Rd. Suite 276 Charlotte, NC 28226 Scharco Elektronik GmbH Tilsiter Strae 8 D-42227 Wuppertal Phone: Telefax: http:// e-Mail: Phone: Telefax: http:// e-Mail: Phone: Telefax: http:// e-Mail: Phone: Telefax: http:// e-Mail: +49 (0) 25 87 / 89 - 0 +49 (0) 25 87 / 89 - 140 www.condor-cpc.com info@condor-cpc.com +49 (0) 25 87 / 895 - 00 +49 (0) 25 87 / 895 - 99 www.condor-systemtechnik.de info@condor-systemtechnik.de +1 704 544-8847 +1 704 756-8397 www.condor-usa.com info@condor-usa.com +49 (0) 202 / 52 601 - 0 +49 (0) 202 / 52 601 - 30 www.scharco.de scharco@scharco.de
www.condor-cpc.com
Page 7.03
Representatives Europe
Austria
Fabig Handelsgesellschaft mbH Felmayergasse 4 A-1214 Wien Phone: Telefax: http:// e-Mail: +43 1 2584 606-0 +43 1 2584 606-229 www.fabig.at aichberger@fabig.at
Benelux
Condor Benelux Postbus 178 NL-2740 AD Waddinxveen Condor Benelux Magazijn Coenecoop 9 NL-PG 2741 Waddinxveen
Great Britain
Alpha Controls PLC First Floor, Unit 5 Ridgeway Estate GB-Iver, Buckinghamsh. SLO9HX Phone: Telefax: http:// e-Mail: +44 1942 52 58 33 +44 1942 52 34 13 www.alphacontrols.co.uk technicalsales@alphacontrols.co.uk
Italy
Mazzeri S.R.L. Via Teodosio 61-65 20131 Milano Phone: Telefax: e-Mail: +39 02 2871 161 +39 02 2828 636 mazzeri@mazzeri.it
Portugal
Casa das Lampadas, Lda. Rua da Arroteia, 894 PT-4465-586 Lea do Balio Phone: Telefax: http:// e-Mail: +351 22 905 90 00 +351 22 902 45 93 www.casadaslampadas.com calamp@casadaslampadas.com
Russia
Econika Techno Alleya Pervoi Mayovki 15 RU-111395 Moscow Phone: Telefax: http:// e-Mail: +7 095 250 6848 +7 095 250 6805 www.et.ru air@et.ru
Spain
Seicom, S. L. (Sensors i Components Ind.) Modolell 39 E-08021 Barcelona Phone: Telefax: http:// e-Mail: +34 932 411 566 +34 934 146 199 www.seicomsl.es comercial@seicomsl.es
Page 7.04
www.condor-cpc.com
Representatives Europe
Sweden
Solar AB Industry Division Electrica P. O. Box 311 S-40 125 Gothenburg Phone: Telefax: http:// e-Mail: +46 19 192 908 +46 19 192 917 www.solar.se solar@solar.se
Switzerland
SM Handels AG Industriestr. 2 CH-8108 Dllikon Phone: Telefax: http:// e-Mail: +41 44 844 06 08 +41 44 844 57 44 www.smhandelsag.ch info@smhandelsag.ch
Turkey
ZETA Enerji Elk. Mak. Tic. Ltd. Sti. Teyyarecci Resmi Sok. Arman A 9/15 TR-34744 Bostanci-Istanbul Phone: Telefax: hhtp:// e-Mail: +90 212 210 97 50 +90 212 220 39 81 www.zetaenerji.com nmadern@zetaenerji.com
www.condor-cpc.com
Page 7.05
Representatives Worldwide
Australia
Ross Brown Sales Pty. Ltd. ACN 000 690 362 21 Brookhollow Ave P.O.Box 6345 BHBC AU-Baulkham Hills NSW 2153 Phone: Telefax: http:// e-Mail: +61 2 9899 2744 +61 2 9899 4233 www.rossbrownsales.com.au sales@rossbrownsales.com.au
Iran
Tehran Condor Sadai Allee P.O.Box 11365-3845 Tehran Phone: Telefax: e-Mail: +98 21 390 4413 +98 21 393 3616 thr_condor@dpimil.net
Korea
Han Young Fluid Co., Ltd. 456-17, Poongmu-Dong, Gimpo-City Gyounggi-Do, 456-17 Korea
Phone: Telefax:
South Africa
AC / DC Dynamics P.O.Box 19287 ZA-Fischers Hill 1408 Phone: Telefax: +27 (11) 8 73-34 74 +27 (11) 8 73-11 3
USA
Condor USA, Inc. 8318 Pineville-Mathews Rd. Suite 276 Charlotte, NC 28226 Phone: Telefax: http:// e-Mail +1 704 544-8847 +1 704 756-8397 www.condor-usa.com info@condor-usa.com
Page 7.06
www.condor-cpc.com
Terms of Delivery
Terms of Delivery
During handling of order the General Terms and Conditions (AGB) of the Condor Pressure Control GmbH are determining. These conditions can be seen under www.condor-cpc.com. The retention of title applies also if our goods are finished or already worked on, as well as with mixture or blending with other goods. For demands from far sales of supplied goods the extended retention of title applies.
You find the current price list on our homepage www.condor-cpc.com as pdf-file for downloading. Place of delivery and area of jurisdiction is Warendorf in Germany.
Impressum
Subject to design changes which serve further development without prior notice. Illustrations, dimensions and possible typing errors are not-binding and without obligation.
www.condor-cpc.com
Page 7.07
Page 7.08
www.condor-cpc.com
Subsidiaries of Condor-Werke
Overview
Page 8.02
8.03
8.04
www.condor-cpc.com
Page 8.01
In the course of expansion of the product service spectrum range "System Technology", Condor Systems GmbH emerges beginning 2003 as an independent corporate division within the Condor group. Consequently, Condor Systems GmbH, carries forth the over 100 year old Condor-Werke tradition in the field of water engineering which originally began with the manufacturing of water pumps.
Fill level measurement Level monitoring, regulation and control Pump controls Rainwater harvesting Septic tank control
Based on customer requirements and specifications, Condor Systems manufactures controls mainly for the pressure and water technology sectors (including waste water sector), shows how a problem can be solved and furnishes technical documentation for manufacturing the control or in advance for units still to be planned. Furthermore, a large part of the components which are used in the controls are manufactured by Condor Systems; this specially ensures safety as well as product and delivery reliability.
In the Thirties - at which time the company was christened Condor - due to it's intensive activity in the field of pump technology, the company was granted a patent which is still relevant up to the present day for diaphragm based pressure switches manufactured all over the world. That laid the foundation in the field of electronic engineering; the era of Condor switchgear had begun. With the manufacturing of electronic monitoring, regulating and control units Condor Systems carries out the next step:
Control
Regulate
Monitor
Is the motto with special focus on complete problem solutions in the range of pressure and water engineering, e.g.: Effluent treatment Pressure measurement, regulation and control Compressor monitoring and control User-specific, individual and tailored, we will gladly present you our problem solving solutions!
Page 8.02
www.condor-cpc.com
Based on long year experience in the field of control engineering, Scharco Elektronik offers customized solutions to almost all sectors of industrial electronics.
water engineering, shop-fitting, gas stations and automobile electronics. In the scope of competent consulting, we analyse the exact conception and requests of our clients. In close co-operation with the client, a team of qualified development engineers create CAE supported diagrams, layouts, software and designs.
Our strength lies in first-rate facilities and the integrated logical system which offers you longterm price stability and flexibility.
This contains: Project management Production and control Development support and technological advice Prototyping Highest efficiency guarantees the production of RoHS compliant products on state of the art SMT and wave soldering machines.
During the entire process, from project planning to batch delivery, all customer specific products are subject to the high quality requirements of ISO 9001:2000. Our highly qualified engineers and more than 40 years of experience in the different industrial branches ensure the success of our products in compliance with relevant standards including those for approval obligatory or safetyrelated controls (TV, PTB, etc.). Our major activity lies in pressure, water and motor technology as well as controls for waste
www.condor-cpc.com
Page 8.03
The illustration above shows a Condor pressure switch which has been especially developed and manufactured for the US market.
Condor USA has its own R&D department in order to exactly match the individual products with the customer's requirements and applications. Here, special products and solutions are developed for the requirements of the US market. Before starting mass production, every product will be thoroughly checked in own test laboratories.
An assembly department ensures the necessary flexibility in order to meet special requests of our customers. All distribution and shipment of the products for customers all over the American continent is handled by a central logistic center in Kentucky.
Page 8.04
www.condor-cpc.com
05.04.2007
www.condor-cpc.com
Page 8.05