Mains voltage Output current Width [mm] Height [mm] Depth [mm] Weight [kg]
1 x 208, 230, 240 V 1.8 x of rated current for 30 secs 70 193 152 1.6 70 218 177 2.3 70 218 177 2.3 70 300 250 4.4 120 300 250 6.5
3 x 400, 440, 460 V 1.5 x of rated current for 60 secs 170 300 250 7.2 250 345 325 20 300 550 305 31 412 500 362 60
CDA3000
Technical Information
the drive solution, with control from 0.75 kW up to 132 kW
Drive features Voltage Frequency Control (VFC) Sensorless Flux Control (SFC) Field Orientation Control (FOR) Output frequency Invertersystem Inputs/outputs
0 ... 400 Hz (0,75 kW to 15 kW), 0 ... 200 Hz (from 22 kW to 132 kW) Analog IN/OUT 2/1 Digital IN/OUT 5/3 Encoderevaluation Optical Encoder Brakechopperelectronics integrated User Modul IN/OUT 8/4 Communication Modul CANLust CANopen PROFIBUS-DP
OELOG 7LWH
Swithing frequency EMC acceptance Interference transmission radiation/ power line Acceptances/ Standard Software performance Ambient temperature Motor monitoring Protection type Motor type
4, 8, 16 kHz (0,75 kW to 15 kW), 4 kHz (from 22 kW to 132 kW) Inverter modules 0.37 to 7.5 kW (internal) For public and industrial environments conforming to EN61800-3 Inverter modules from 11 to 132 kW (external) For public and industrial environments conforming to EN61800-3 CE, cUL 16 selectable drive solutions for horizontal, vertical and rotational drive 4 user data sets, freely available 0 ... 45 C, max. 55 C Klixon, PTC and linear PTC IP20 Inverter, IP54 cooling design DS standard motor, synchro-motor, reluctance motor, asynchronous servo-motor 38 software functions such as power failure protection, data record switching, etc.
Adress:
Lust Antriebstechnik GmbH Gewerbestr. 5-9 D-35633 Lahnau Internet:http://www.lust-tec.de email: info@lust-tec.de
VA L
SM A CA RT RD
ANTR
H1
H2
H3
Typ Net
X4
z: Aus g.:
VAL
Hz
SN .: 000.0
00.00
0000
00
Hz
X2
X1
U V W
X3
RB RB L-
L1 L2 L3
ATTENTION WARNING ACHTUNG Kondensatorent- capacitor disschargetemps de decharge ladezeit >3 Min. time >3 minutes. du condensteur BetriebsanleitungPay attention to the >3 min. observer le operation manual! mode dmploi! beachten!
Tradition
We have continued our tradition that dates back many years, and in addition have established technical feedback and control standards in drive technology, along with creating important and essential building blocks for future-oriented flexibility in machines and systems.
Keep cool
Inverters need to stay cool for the output components to be used to their full potential. Only the modular cooling concept has been able to ensure a free selection of whatever installation situation happens to be present. Whether it is a cold plate or with heat sink inside or outside the installation area, it is possible to make a situation-based decision.
wall mounted
VAL
Hz
1 2
ANTRIEBSTECHNIK
Cold Plate
stop return
start enter
2 5 6 3 7 4 8 5 9 6 10 7 11 8 12 9 10 16 11 12 16 17 18 19 1 2
20
17 18 1 19 2 20
The new inverter system is designed so that in spite of extended functions and extensive system components, the user can configure and implement into operation optimal drive solutions even faster and more simply.