340MAV
Sizes 040 thru 140
Sealed Combustion (Direct-Vent) SystemEnclosed burner assembly isolates operating noise without the expense of sound deadening devices. The sealed combustion (direct-vent) system brings outdoor air directly into the combustion chamber, reducing infiltration of cold air into the structure and reducing heat loss. 3-Pass Primary Heat ExchangersThis design accelerates heat transfer and extracts heat that conventional heat exchangers waste up the flue. The primary heat exchanger is made of aluminized steel for corrosion resistance. Flow-Through Secondary Heat ExchangersEach cell is laminated with our patented EverlasticTM polypropylene for greater resistance to corrosion. This breakthrough in heating technology helps extend the life of the furnace for years of dependable performance. The heat exchanger is positioned in the furnace to extract additional heat from the combustion products regardless of furnace orientation. WarrantyThe 340MAV is backed by a 20-year Limited Warranty on the heat exchangers and a 1-year Limited Warranty on all other parts. Control CenterThe printed-circuit board and all internal wiring are factory installed. Convenient terminals permit quickconnection of a thermostat and air conditioning control circuits. Connections for a humidifier and air cleaner are also provided. The control has a built-in status indicator and self-test feature. The status indicator flashes to indicate a problem condition and assists the servicer in diagnosis. The self-test feature allows for a complete check of the major components in only seconds. The model 340MAV Multipoise Condensing Furnace is specifically designed to meet the needs of the new construction market. This high-efficiency furnace utilizes a unique 4-way multipoise design and compact size to fit where other furnaces will not. The model 340MAV can be installed in any of 4 positions including horizontally in attics or crawlspaces, freeing space formerly used as a utility or furnace room. Except for the 140 size, all sizes of the model 340MAV can be installed in a manufactured (mobile) home when the optional kit is used. Sidewall or through-the-roof venting options and the use of PVC pipe eliminate the need for dedicated chimneys or chaseways to facilitate furnace venting. Time-saving installation features yield a very cost effective way to provide new home buyers with a high-efficiency and high-quality home comfort system. Combustion Air and VentilationThe 340MAV advanced design allows Schedule 40PVC, PVC-DWV, SDR-21 PVC, SDR-26 PVC (not approved in Canada), ABS-DWV, or ABSF628 Schedule 40 pipe to bring outdoor air into the furnace for combustion. The extracted heat lowers the temperature of the combustion products to a point (typically below 115F) that any of the approved types of pipe can also be used for venting combustion products outside the structure. The combustion-air and vent pipes can terminate through a side wall or through the roof when using 1 of our approved vent termination kits. Insulated CasingFoil-faced insulation in the heat exchanger section cuts heat loss. The casing also has the required openings for left- or right-side connection of gas, electric, drain, and vent connections. CertificationsThe 340MAV units are A.G.A. and C.G.A. design certified for use with natural and propane gases, as well as GAMA efficiency rating certified. The furnace is factoryshipped for use with natural gas. A CSA (A.G.A./C.G.A.) listed gas conversion kit is required to convert furnace for use with propane gas. The model 340MAV meets California Air Quality Management District emission requirements. Except for the 140 size unit, all 340MAV models can be installed in a manufactured (mobile) home when the optional kit is used. Quality RegistrationThe 340MAV is engineered and manufactured under an ISO 9001 registered quality system.
FEATURES
4-Way Multipoise DesignAllows a model 340MAV to be installed in an upflow, downflow, or horizontal orientation. The model 340MAV is available in 12 heat/airflow combinations, and when combined with the 4-way design, allows for 48 different applications. Factory configured for upflow application, this furnace can easily be made ready for downflow or horizontal installations.
26 14" A
13
28 12" 26 1516"
24 12" /16" D OUTLET 2-IN. COMBUSTIONAIR CONN 2-IN. DIA GAS CONN
1 7
22 /16" OUTLET CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL LEFT)
7 9 16" TYP
516"
16" 8"
CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL RIGHT) OR ALTERNATE 1 2-IN. DIA GAS CONN 8-IN. DIA POWER CONN
16"
1 7
2-IN. DIA THERMOSTAT ENTRY 22 1116" 8-IN. DIA ACCESSORY POWER ENTRY 29 1116" TYP 27 58" 27 916" TYP 24 12" 18 14" 30 2"
1
39 78"
22 1116"
14 12" TYP
SIDE INLET
SIDE INLET
1"
INLET
11/16"
114" 1" E
11/16"
16"
11
2 DIMENSIONS (In.)
UNIT SIZE A D E
26 1516" TYP
16"
NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturers recommendations for equivalent diameters. 2. Minimum return-air opening at furnace: a. For 800 CFM16-in. round or 141/2 x 12-in. rectangle. b. For 1200 CFM20-in. round or 141/2 x 191/2-in. rectangle. c. For 1600 CFM22-in. round or 141/2 x 231/4-in. rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM at 0.5 W.C. ESP.
A02147
024040 036040 024060 036060 048060 036080 048080 060080 048100 060100 060120 060140
15-7/8 15-7/8 15-7/8 15-7/8 15-7/8 15-7/8 15-7/8 19-3/8 19-3/8 19-3/8 22-7/8 22-7/8
165 166 172 174 174 188 194 206 219 221 250 250
CLEARANCE TO COMBUSTIBLES
INSTALLATION
This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size Furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications. This furnace is for indoor installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate and using factory authorized kit. This furnace may be installed on combustible flooring in alcove or closet at minimum clearance from combustible material. This appliance requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC, PVC-DWV, CPVC, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials). Cette fournaise air puls est quipe pour utilisation avec gaz naturel et altitudes comprises entre 0 - 3,050m (0-10,000 pi), except queles fournaises de 140 taille sont pour altitudes comprises entre 0 - 2,135m (0 - 7,000 pi). Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel. Cette fournaise air puls est pour installation lintrieur dans un btiment construit sur place. Cette fournaise air puls peut tre installe dans une maison prfabrique (maison mobile) si prescrit par la plaque signaltique et si lon utilise une trousse specifie par le fabricant. Cette fournaise peut tre installe sur un plancher combustible dans un enfoncement ou un placard en observant les dgagements minimums avec les matriaux combustibles. Cet appareil ncessite un systme dvacuation spcial. La mthode dinstallation et la liste des pices ncessaires figurent dans les instructions dinstallation.Cette fournaise doit sutiliser avec la tuyauterie des nomenclatures 40 PVC, PVC-DWV, CPVC, ou ABS-DWV et elle ne peut pas tre ventile conjointment avec dautres appareils gaz. paisseur de la construction au travers de laquelle il est possible de faire passer les tuyaux daration (admission/vacuation): 24 po (600 mm) maximum, 3/4 po (19 mm) minimum (y compris la toiture).
For upflow and downflow applications, furnace must be installed level, or pitched within 1/2" of level. For a horizontal application, the furnace must be pitched minimum 1/4" to maximum of 1/2" forward for proper drainage. See Installation Manual for IMPORTANT unit support details on horizontal applications. Pour des applications de flux ascendant et descendant, la fournaise doit tre installe de niveau ou incline pas plus de 1/2" du niveau. Pour une application horizontale, la fournaise doit tre incline entre minimum 1/4" et maximum 1/2" du niveau pour le drainage appropri. En cas d'installation en position horizontale, consulter les renseignements IMPORTANTS sur le support dans le manuel d'installation.
ALL POSITIONS:
R
UPFLOW OR DOWNFLOW
FRONT
FRONT
HORIZONTAL
This furnace is approved for UPFLOW, DOWNFLOW and HORIZONTAL installations. Cette fournaise est approuve pour linstallation HORIZONTALE et la circulation dair VERS LE HAUT et VERS LE BAS. Clearance arrows do not change with furnace orientation.
Minimum front clearance for service 30 inches (762mm). 140 size furnaces require 1 inch back clearance to combustible materials. For installation on combustible floors only when installed on special base No. KGASB0201ALL, Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC. Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket, and building joists, studs, or framing. Clearance shown is for air inlet and air outlet ends. 120 and 140 size furnaces require 1 inch bottom clearance to combustible materials.
DOWNFLOW POSITIONS:
1"
TOP/PLENUM DESSUS/CHAMBRE DAI
HORIZONTAL POSITIONS:
Les flches de dgagement ne change pas avec lorientation de la gnrateur dair chaud.
0"B
R
A C RI K ER E
Pour les fournaises de 140 taille, 1 po (25mm) dgagement des matriaux combustibles est requis
au-arriere.
POUR LA POSITION COURANT DESCENDANT:
E AC SE RN A I F U URN T O ON F F R AN T AV
DE SI E S T CO
0"
Pour linstallation sur le plancher combustible seulement quand on utilise la base spciale, pice
POUR LA POSITION HORIZONTALE:
Le contact nest permis qentre les lignes formes par les intersections du dessus et des deuxcts de la chemise de la fournaise, et des solives, des montants ou de la charpente du btiment. La distance indique concerne lextrmit du tuyau darrive dair et lextrmit du tuyau de sortie dair. Pour les fournaises de 120 et 140 taille, 1 po (25mm) dgagement des matriaux combustibles est requis au-dessous.
BOTTOM DESSOUS
n KGASB0201ALL, lensemble serpentin, pice n CD5 ou CK5, ou le carter de serpentin, pice n KCAKC.
0"
DE SI E S T CO
F R A V ON T A NT
S E NT R VI RE C TI E EN
* 30
3"
MIN
0"
A02148
* Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application.
* Model HP and 2S thermostat must be field converted to air conditioner operation. **Dual Fuel thermostat is used with furnace and heat pump application ***Thermidistat Control can be configured for multiple use and staging, it must be configured for each specific application.
SPECIFICATIONS
UNIT SIZE RATINGS AND PERFORMANCE Input Btuh* Output Capacity Nonweatherized ICS AFUE% Certified Temperature Rise Range F Certified External Static Pressure Airflow CFM ELECTRICAL Unit VoltsHertzPhase Operating Voltage Range MinMax** Maximum Unit Amps Unit Ampacity Minimum Wire Size Maximum Wire Length (Ft) Maximum Fuse Size or Ckt Bkr Amps (Time-Delay Type Recommended) Transformer (24v) External Control Power Available Air Conditioning Blower Relay CONTROLS Limit Control Heating Blower Control (Off Delay) Burners (Monoport) Gas Connection Size GAS CONTROLS Gas Valve (Redundant) Manufacturer Min Inlet Pressure (In. wc) Max Inlet Pressure (In. wc) Ignition Device BLOWER DATA Direct-Drive Motor HP (Permanent Split Capacitor) Motor Full Load Amps RPM (Nominal)Speeds Blower Wheel Diameter x Width (In.) Filter Size (In.)Permanent Washable FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS Gas Conversion KitNatural-to-Propane Gas Conversion KitPropane-to-Natural Twinning KitUpflow ONLY Manufactured (Mobile) Home Kit Downflow Base*** Vent Termination Kit (Bracket Only for 2 Pipes) Concentric Vent Termination Kit (Single Exit) Condensate Freeze Protection Kit Side Filter Rack (Without Filter)Upflow ONLY Electronic/Mechanical Air Cleaner Humidifier Heat/Energy Recovery Ventilator N/A KGAMH0101KIT KGASB0201ALL 2-in.KGAVT0101BRA 2-in.KGAVT0501CVT 3-in.KGAVT0201BRA 3-in.KGAVT0601CVT KGANP2901ALL KGAPN2301ALL
KGATW0601HSI
024040 40,000 Multipoise Upflow/Horizontal Downflow Heating Cooling Heating Cooling 37,000 92.1 91.0 3060 0.10 0.50 850 895
036040 40,000 37,000 92.1 91.0 1545 0.10 0.50 1125 1215
024060 60,000 56,000 92.1 91.0 4575 0.12 0.50 885 900
036060 60,000 56,000 92.1 91.0 3060 0.12 0.50 1065 1200
048060 60,000 56,000 92.1 91.0 2050 0.12 0.50 1320 1545
036080 80,000 74,000 92.1 91.0 4070 0.15 0.50 1190 1245
115601 104127 6.1 8.4 14 44 15 Heating Cooling 7.3 10.0 14 37 15 6.1 8.4 14 44 15 40va 12va 21va Standard SPST Factory-Set at 135 Sec 2 2 3 1/2-in. NPT White-Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Hot Surface 1/5 4.9 10753 10 x 6 1/3 5.8 10754 10 x 7 1/5 4.9 10753 10 x 6 10 x 7 (1) 16 x 25 x 1 1/3 5.8 1/2 7.9 10754 11 x 8 1/3 5.8 10 x 7 3 3 4 7.1 9.8 14 38 15 9.5 12.8 14 29 15 7.6 10.4 14 36 15
N/A
KGAHT0101CFP KGAFR0206ALL Model AIRA, 902B, MACA, or FILCAB Model HUM Model HRV
SPECIFICATIONS Continued
UNIT SIZE RATINGS AND PERFORMANCE Input Btuh* Output Capacity Nonweatherized ICS AFUE% Certified Temperature Rise Range F Certified External Static Pressure Airflow CFM ELECTRICAL Unit VoltsHertzPhase Operating Voltage Range MinMax** Maximum Unit Amps Unit Ampacity Minimum Wire Size Maximum Wire Length (Ft) Maximum Fuse Size or Ckt Bkr Amps (Time-Delay Type Recommended) Transformer (24v) External Control Power Available Air Conditioning Blower Relay CONTROLS Limit Control Heating Blower Control (Off Delay) Burners (Monoport) Gas Connection Size GAS CONTROLS Gas Valve (Redundant) Manufacturer Min Inlet Pressure (In. wc) Max Inlet Pressure (In. wc) Ignition Device BLOWER DATA Direct-Drive Motor HP (Permanent Split Capacitor) Motor Full Load Amps RPM (Nominal)Speeds Blower Wheel Diameter x Width (In.) Filter Size (In.)Permanent Washable FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS Gas Conversion KitNatural-to-Propane Gas Conversion KitPropane-to-Natural Twinning KitUpflow ONLY Manufactured (Mobile) Home Kit Downflow Base*** Vent Termination Kit (Bracket Only for 2 Pipes) Concentric Vent Termination Kit (Single Exit) Condensate Freeze Protection Kit Side Filter Rack (Without Filter)Upflow ONLY Electronic/Mechanical Air Cleaner Humidifier Heat/Energy Recovery Ventilator KGANP2901ALL KGAPN2301ALL KGATW0601HSI KGAMH0101KIT KGASB0201ALL 2-in.KGAVT0101BRA 2-in.KGAVT0501CVT 3-in.KGAVT0201BRA 3-in.KGAVT0601CVT N/A N/A 11 x 8 11 x 10 11 x 8 (1) 20 x 25 x 1 1/2 7.9 3/4 11.1 1/2 7.9 10754 11 x 10 11 x 10 11 x 10 (2)16 x 25 x 1 3/4 11.1 3/4 11.1 3/4 11.1 White-Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Hot Surface 4 4 5 1/2-in. NPT SPST Factory-Set at 135 Sec 5 6 6 Heating Cooling 10.0 13.4 14 28 20 14.1 18.4 12 31 15 10.2 13.5 14 27 20 40va 12va 21va Standard 115601 104127 14.8 19.3 12 30 20 14.6 19.1 12 30 20 14.3 18.8 12 30 20 Heating Cooling Heating Cooling Multipoise Upflow/Horizontal Downflow 80,000 74,000 92.1 91.0 3060 0.15 0.50 1285 1525 80,000 74,000 92.1 91.0 2050 0.15 0.50 1785 1925 100,000 93,000 92.1 91.0 4575 0.20 0.50 1315 1570 100,000 93,000 92.1 91.0 3060 0.20 0.50 1690 1930 120,000 112,000 92.1 91.0 4070 0.20 0.50 1720 2000 138,000 127,000 92.0 91.0 5080 0.20 0.50 1970 1990 048080 060080 048100 060100 060120 060140
KGAHT0101CFP KGAFR0206ALL Model AIRA, 902B, MACA, or FILCAB Model HUM Model HRV
* Gas input ratings are certied for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate the unit 5% from 2000 to 4500 ft above sea level. Capacity and AFUE in accordance with U.S. Government DOE test procedures. Airow shown is for bottom only return-air supply. Air delivery above 1800 CFM may require that both sides, a combination of 1 side and bottom, or bottom only of the furnace be used for return air, see Air Delivery table. Where 2 sets of data are listed, the rst set is for bottom only return-air supply. The second set is for both sides, or 1 side and bottom return-air supply. A lter is required for each return-air supply. ** Permissible voltage limits for proper furnace operation. Unit ampacity = 125% of largest components full load amps plus 100% of all other potential operating components (EAC, humidier, etc.). Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. *** Required for installation on combustible oors when no coil box is used, or when any coil box other than a Bryant CD5, CK5, or KCAKC cased coil is used. N/ANot applicable ICSIsolated Combustion System
UNIT SIZE 024040 036040 024060 036060 048060 036080 048080 060080
1 5 70 70 20 70 10 55 70 5 40 70 10 45 70 5 40 60 70 67 70 17 70 49
2 NA 70 70 15 70 NA 50 70 NA 30 70 NA 40 70 NA 35 56 70 62 70 12 67 44
5 NA 60 70 NA 70 NA 30 70 NA 10 70 NA 25 70 NA 20 44 70 52 70 NA 61 25
6 NA 55 70 NA 70 NA 20 70 NA NA 70 NA 20 70 NA 15 40 70 47 70 NA 61 15
0 to 2000
060140 024040 036040 024060 036060 048060 036080 048080 060080 048100 060100 060120
2001 to 3000
060140 024040 036040 024060 036060 048060 036080 048080 060080 048100 060100 060120 060140 024040 036040 024060 036060 048060 036080 048080 060080 048100 060100 060120 060140 See notes on page 7.
3001 to 4000
4001 to 5000
5001 to 6000
6001 to 7000
7001 to 8000
8001 to 9000
9001 to 10,000
* Disk usageUnless otherwise specied, use perforated disk assembly (factory-supplied in loose parts bag). If 1 disk is stated, separate 2 halves of perforated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box. Wide radius elbow. Vent sizing for Canadian installations above 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction. NANot Allowed; pressure switch will not make. NOTES: 1. Do not use pipe size greater than those specied in table or incomplete combustion, ame disturbance, or ame sense lockout may occur. 2. Size both the combustion-air and vent pipe independently, then use the larger diameter for both pipes. 3. Assume two 45 elbows equal one 90 elbow. Long radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 5. The minimum pipe length is 5 ft for all applications. 6. Use 3 in. diameter vent termination kit for installations requiring 4 in. diameter pipe.
MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*
UNIT SIZE 024040 036040 WINTER DESIGN TEMPERATURE (F) 20 0 20 024060 036060 048060 036080 048080 060080 20 0 20 20 0 20 20 048100 060100 0 20 20 060120 0 20 20 060140 0 20 MAX PIPE DIAMETER (IN.) 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 3 3 3 4 4 4 4 4 4 WITHOUT INSULATION 51 28 16 65 35 20 70 47 28 70 50 28 70 48 23 70 57 30 WITH 3/8-IN. OR THICKER INSULATION 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70
* Pipe length (ft) specified for maximum vent pipe lengths located in unconditioned spaces. Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in Maximum Allowable Pipe Length table. Insulation thickness based on R value of 3.5 per in.
CONDENSATE TRAP
BLOWER SHELF CONDENSATE TRAP (INSIDE) FURNACE DOOR CONDENSATE TRAP FURNACE SIDE FURNACE DOOR
FURNACE SIDE
4 78
4 534 4 26 1 4
34
534
26 1 4
11 2
SIDE VIEW
FRONT VIEW
END VIEW
FRONT VIEW
UPFLOW APPLICATIONS
HORIZONTAL APPLICATIONS
14
OD COLLECTOR BOX TO TRAP RELIEF PORT OD INDUCER HOUSING DRAIN CONNECTION OD COLLECTOR BOX DRAIN CONNECTION
12
58
PVC OR CPVC
FRONT VIEW
SIDE VIEW
A93026
ama
MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
A PP R O VED R
As an ENERGY STARSM Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency.
REGISTERED QUALITY SYSTEM These products are engineered and manufactured under an ISO 9001 registered quality system.
10
ACCESSORIES
B IN. DIA PVC VENT/EXHAUST
CONCENTRIC VENT
1 14 (TYP)
2 38 1 14 25 18
3
17 18
23 18 OPENING
16 18 14 12 OPENING
A80199
NOTE: See furnace Installation Instructions when venting multiple furnaces near each other.
A97110
DIMENSIONS (In.)
PART NO. KGAVT0501CVT KGAVT0601CVT A* 33-3/8 38-7/8 B 2 3 C 3-1/2 4-1/2 D 16-5/8 21-1/8 E 6-1/4 7-3/8 F 5-3/4 6-1/2
* Dimension A will change accordingly as dimension D is lengthened or shortened. Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. minimum.
B D
LOCATING TAB
1 2 3 4
Disassembled
;;;; ;;;;
1 1/4 TYP PLENUM OPENING
A97427
Assembled
PLENUM OPENING* FURNACE IN DOWNFLOW APPLICATION Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box A 15-1/8 18-5/8 22-1/8 B 19 19 19
* The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above.
11
036040
024060
036060
048060
036080
048080
060080
060100
* A lter is required for each return-air supply. For horizontal and downow applications, use 1 side or bottom or bottom only as airow reference.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS 340M.40.10
2002 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indianapolis, IN 46231
12
PRINTED IN U.S.A.
7-02