Professional Documents
Culture Documents
3rd Edition
DSX-1
Table of Contents
FlexDSX Family
Introduction Design Elements...................................................................................................23-24
84-Termination Rear Cross-Connect Panels..................................................................................25
84-Termination Front Cross-Connect Panels.................................................................................26
64-Termination Front Cross-Connect Panels.................................................................................27
56-Termination Front Cross-Connect Panels.................................................................................28
Front or Rear Cross-Connect Skeleton Bays..................................................................................29
Rack Hardware.......................................................................................................................30-31
Super High-Density Bay and Rear Cross-Connect System.........................................................32-34
Specialty Panels
FlexDSX Multifunction Panel...................................................................................................35-36
Modular DS1/DS3 Combination Panel..........................................................................................37
103253AE
DSXi Family
Introduction Design Elements..........................................................................................................9
84-Termination Rear Cross-Connect Panels..................................................................................10
64-Termination Rear Cross-Connect Panels..................................................................................11
56-Termination Rear Cross-Connect Panels..................................................................................12
84-Termination Front Cross-Connect Panels.................................................................................13
64-Termination Front Cross-Connect Panels.................................................................................14
56-Termination Front Cross-Connect Panels.................................................................................15
84-Termination Total Front Access Cross-Connect Panels..............................................................16
64-Termination Total Front Access Cross-Connect Panels..............................................................17
56-Termination Total Front Access Cross-Connect Panels..............................................................18
Rear Cross-Connect Skeleton Bays...............................................................................................19
Front Cross-Connect Skeleton Bays..............................................................................................20
Rack Hardware.......................................................................................................................21-22
6/07
DSX-1
Introduction
Cross-Connect System...................................................................................................................1
Connecting with Your Network..................................................................................................2-3
Bantam Jack Technology Features..................................................................................................4
Panel Configuration Features ........................................................................................................5
Skeleton Bay Lineup Features......................................................................................................6-7
Product Family Features.................................................................................................................8
www.adc.com
+1-952-938-8080
1-800-366-3891
DSX-1
Table of Contents
6/07
103253AE
DSX-1
Auxiliary Equipment
Cross Aisle Panels...................................................................................................................44-45
Interbay Patch Panels..............................................................................................................46-47
Bay Tracer Illuminator.................................................................................................................48
DS1 Repeaters........................................................................................................................49-50
Communications Panels...............................................................................................................51
Communications Panel Accessories and Writing Shelves..............................................................52
Fuse Panels..................................................................................................................................53
Horizontal Cable Troughs.............................................................................................................54
Horizontal Ring Panels.................................................................................................................54
Accessories
Bantam Plugs...............................................................................................................................55
Terminating Plugs....................................................................................................................55
Looping Plugs..........................................................................................................................55
Hole Plugs...............................................................................................................................55
Conversion Plugs.....................................................................................................................55
Dummy Plugs..........................................................................................................................55
Circuit Guard Plugs..................................................................................................................56
Ordering Information...............................................................................................................57
Patch Cords.................................................................................................................................58
Three-Conductor.....................................................................................................................58
Conversion..............................................................................................................................59
Patch Cords Specialty................................................................................................................60
Alligator Patch Cords...............................................................................................................60
EZ Hook Patch Cords...............................................................................................................60
Banana-Type Patch Cords........................................................................................................60
BNC to Bantam Plug Patch Cords............................................................................................61
RJ11 Telephone Plug to Bantam Plug Patch Cords....................................................................61
Bantam Plug to AT&T 800 Style Plug Patch Cords....................................................................61
Ordering Information...............................................................................................................62
Patch Cords Accessory Kits . .....................................................................................................63
Patch Cords Controlled Environment Vault Kits ........................................................................64
Cross-Connect Wire.....................................................................................................................65
Wire-Wrap Tool Kits.....................................................................................................................65
Replacement LED Modules...........................................................................................................66
Index.......................................................................................................................................................... 67-69
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
Cross-Connect System
Increased demand for optimal network
performance has created a greater need for
reliable connectivity equipment. ADCs digital
signal cross-connect (DSX) products provide
a competitive advantage by managing digital
equipment and maintaining superior cable
management. DSX equipment is used as a
centralized cross-connect interface between
network elements (NE), enabling nonintrusive and
intrusive access for testing, patching, and circuit
reconfiguration without disturbing permanent
equipment connections.
6/07
103253AE
DSX-1
Technology
The DSX interface enables patching, terminating
and rearranging of circuits as traffic patterns
change and demands on the network grow.
At DS1 (1.544 Mbps) digital signal rates, DSX
equipment connects NEs such as office repeaters,
digital switches, channel banks, digital loop
carriers, multiplexers, and digital loop switches.
DSX-1
MON
MON
OUT
Tx OUT
IN
Rx IN
Equipment
Cable
X-OUT
OUT
IN
Network
Element B
DSX-1
X-OUT
Out
IN
X-IN
M
O
I
OUT
Tx OUT
IN
Rx IN
X-IN
CrossConnect
Jumper
Equipment
Cable
Application
The management of equipment cables and cross-connect jumpers is addressed at the DSX bay
framework, ensuring an organized and expandable network. The DSX system should be placed in a
centralized location. Whether in a central office, remote site, or wireless bay station or hub, DSX delivers
a flexible centralized location to access and monitor network signals.
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
6/07
103253AE
DSX-1
Circuit access
Flexibility
Change is inevitable. In todays dynamic,
evolving networks, it isnt a matter of if things
will changeits a matter of how much. Todays
communications networks demand a migration
platform equipped with the cable management
and physical rearrangement flexibility to
accommodate new services and network
elements. Todays networks demand the flexibility
of DSX.
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
6/07
103253AE
DSX-1
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
Typical Cross-Connect
DSX-1
Mult. to - 48V
Mult. to - 48V
Mult. to Shield Gnd
Mult. to Gnd
MON
R
T
OUT
IN
Typical
Cross-connect
IN/OUT
Pins
T
OUT
Digital R
Switch T
R IN
T
R
Cross-Connects
TRACER
OUT
OUT
IN
IN
R2
MON
R
T
OUT
IN
SemiPermanent
Connections
(Cross-Connect)
T
R
Cross-Connects
TRACER
OUT
IN
6/07
To
Office
Repeater A
IN
Mult. to - 48V
Mult. to Shield Gnd
Mult. to Gnd
R2
MON
R
T
OUT
Typical
Patch
IN/OUT
Pins
OUT T
R
T
IN R
OUT
Jackfield
TL
103253AE
Jackfield
TL
IN
Temporary Patch Connections
Supercede Semi-Permanent
Connections at Cross-Connects
T
R
Cross-Connects
TRACER
T
R
T
R2 = 430 ohms
OUT
OUT
IN
IN/OUT
Pins
T
OUT R
T
IN R
To
Office
Repeater B
IN
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
Rear
Cross-Connect
Rear cross-connect panels feature jacks on the
front of the panel. Equipment cable interfaces
and cross-connect interfaces are located on the
rear of the panel.
DSX-1
Front (Split)
Cross-Connect
Front (split) cross-connect panels feature both
jacks and cross-connect interfaces on the front of
the panel. Half of the cross-connects are on the
left side of the jacks, half are on the right side.
Equipment cable interfaces are located on the
rear of the panel.
103253AE
Front (Below)
Cross-Connect
Front (below) cross-connect panels feature both
jacks and cross-connect interfaces on the front of
the panel. The entire cross-connect field is located
below the jacks. Equipment cable interfaces are
located on the rear of the panel.
6/07
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
103253AE
DSX-1
6/07
2.13 m x 190.5 mm
(7' X 7.5") Rack Filler Panel
Rear
Jumper Trough
Fuse Panel
Reserve Panel
Panel #14
Panel #13
Panel #12
Panel #10
Panel #9
Panel #8
Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2
Panel #1
Rear
Jumper Trough
Rear
Jumper Trough
Fuse Panel
Reserve Panel
Panel #14
Panel #13
Panel #12
Panel #10
Panel #9
Panel #8
Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2
Panel #1
Rear
Jumper Trough
Rear
Jumper Trough
Fuse Panel
Reserve Panel
Panel #14
Panel #13
Panel #12
Panel #10
Panel #9
Panel #8
Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2
Panel #1
Rear
Jumper Trough
660 mm
(26")
660 mm
(26")
660 mm
(26")
63.5 mm
(2.5")
63.5 mm
(2.5")
190.5 mm
(7.5")
190.5 mm
(7.5")
Rear
Jumper Trough
Fuse Panel
Reserve Panel
Panel #14
Panel #13
Panel #12
Panel #10
Panel #9
Panel #8
Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2
Panel #1
Rear
Jumper Trough
63.5 mm (2.5")
190.5 mm
(7.5")
Growth
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
6/07
103253AE
DSX-1
www.adc.com
+1-952-938-8080
1-800-366-3891
Introduction
FlexDSX
Panels
Modular
Bantam
Panels
Front Cross-Connect
Rear Cross-Connect
Fixed-Circuit Panels
Modular Chassis
Removable Jacks
Single Monitor Jack (3 ports)
Dual Monitor Jacks (4 ports)
In-Service Patching
Ability to Prewire Backplane
without Jacks
Tracer LEDs
Designation Labels
WECO/EIA Mounting
84
84
112
84
Interconnect
Panels
6/07
103253AE
DSX-1
Feature
www.adc.com
+1-952-938-8080
1-800-366-3891
DSXi Family
Features
Increased density
Up to 27 percent greater bay density, saving
valuable floor space.
Innovative design
Easier circuit access and faster identification to
help save time and money.
Brighter LED
Improved designation
Increased density
Sleek, ergonomic design
Front View
6/07
103253AE
DSX-1
Wire-wrap connections
Rear View
www.adc.com
+1-952-938-8080
1-800-366-3891
DSXi Family
Di-G2CU1
(Rear View)
CrossConnect
IN/OUT
Cabling
6/07
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Rear
Wire-wrap
1-28 A
1-28 B
1-28 C
Di-G2GU1
Rear
Wire-wrap
1-84
Di-G2CU1
Rear
64-pin
1-28 A
1-28 B
1-28 C
Di-G3GU1
Rear
64-pin
1-84
Di-G3CU1
Rear
Wire-wrap
1-28 A
1-28 B
1-28 C
Di-F2GU1*
Rear
Wire-wrap
1-84
Di-F2CU1*
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
10
DSXi Family
Di-D2CU1
(Rear View)
CrossConnect
IN/OUT
Cabling
Dimensions
(HxWxD)
Designation
Mounting
Options
Catalog
Number
Rear
Wire-wrap
1-32 A
1-32 B
Di-D2GU1*
Rear
Wire-wrap
1-64
Di-D2CU1*
6/07
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
11
DSXi Family
Di-A2GU1
(Rear View)
CrossConnect
IN/OUT
Cabling
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Rear
Wire-wrap
1-28 A
1-28 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A2GU1*
Rear
Wire-wrap
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A2CU1*
Rear
64-pin
1-28 A
1-28 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A3GU1*
Rear
64-pin
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A3CU1*
6/07
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
12
DSXi Family
Di-M2GU1
(Front View)
6/07
Di-M2GU1
(Rear View)
Ordering Information
CrossConnect
IN/OUT
Cabling
Dimensions
(HxWxD)
Designation
Mounting
Options
Catalog
Number
Front
(split)
Wire-wrap
1-28 A
1-28 B
1-28 C
Di-M2GU1
Front
(split)
Wire-wrap
1-84
Di-M2CU1
Front
(split)
64-pin
1-28 A
1-28 B
1-28 C
Di-M3GU1
Front
(split)
64-pin
1-84
Di-M3CU1
Front
(below)
Wire-wrap
1-28 A
1-28 B
1-28 C
Di-T2GU1*
Front
(below)
Wire-wrap
1-84
Di-T2CU1*
103253AE
DSX-1
www.adc.com
+1-952-938-8080
1-800-366-3891
13
DSXi Family
Di-K2GU1
(Front View)
Di-K2GU1
(Rear View)
103253AE
DSX-1
Ordering Information
CrossConnect
IN/OUT
Cabling
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Front
(split)
Wire-wrap
1-32 A
1-32 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-K2GU1
Front
(split)
Wire-wrap
1-64
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-K2CU1
Front
(below)
Wire-wrap
1-32 A
1-32 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-R2GU1*
Front
(below)
Wire-wrap
1-64
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-R2CU1*
6/07
www.adc.com
+1-952-938-8080
1-800-366-3891
14
DSXi Family
4"
Di-H2GU1
V:-42/-56VDC
A: 2A MAX.
Di-H2GU1
(Rear View)
IN/OUT
Cabling
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Wire-wrap
1-28 A
1-28 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H2GU1*
Front
(split)
Wire-wrap
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H2CU1*
Front
(split)
64-pin
1-28 A
1-28 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H3GU1*
Front
(split)
64-pin
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H3CU1*
Front
(below)
Wire-wrap
1-28 A
1-28 B
Flush,
19"
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N2GU1*
Front
(below)
Wire-wrap
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N2CU1*
Front
(below)
64-pin
1-28 A
1-28 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N3GU1*
Front
(below)
64-pin
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N3CU1*
103253AE
Front
(split)
CrossConnect
6/07
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
15
4"
DSXi Family
Ordering Information
CrossConnect
IN/OUT
Cabling
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Total
front
access
Wire-wrap
1-28 A
1-28 B
1-28 C
Di-X2GU1
Total
front
access
Wire-wrap
1-84
Di-X2CU1
6/07
103253AE
DSX-1
www.adc.com
+1-952-938-8080
1-800-366-3891
16
DSXi Family
CrossConnect
IN/OUT
Cabling
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Total
front
access
Wire-wrap
1-32 A
1-32 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-W2GU1
Total
front
access
Wire-wrap
1-64
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-W2CU1
6/07
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
17
DSXi Family
Di-U2GU1
(Front View)
Di-U2GU1
REAR VIEW
ROTATED 180?
(Rear View)
CrossConnect
IN/OUT
Cabling
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Total
front
access
Wire-wrap
1-28 A
1-28 B
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-U2GU1*
Total
front
access
Wire-wrap
1-56
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-U2CU1*
6/07
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
18
DSXi Family
Features
Accommodates rear cross-connect style
DSXi panels
35
30
35
RESERVE FOR
MISCELLANEOUS APPLICATION
30
RESERVE FOR
MISCELLANEOUS APPLICATION
25
20
2.14 m
(7')
20
2.14 m
(7')
15
15
10
10
6/07
103253AE
DSX-1
5
5
1
1
658 mm
(25.9") 658 mm
(25.9")
DMB-77WC01
(Front View)
381 mm
(15") 381 mm
Footprint (15")
Footprint
(Side View)
Ordering Information
Dimensions
(HxWxD)
Description
Catalog
Number
19" bay
Rear cross-connect skeleton bay, empty
Accommodates up to (14) 102 mm (4") high
56-termination panels, 784 terminations
DMB-77WC02
DMB-77WC01
DMB-72WC02
DMB-72WC01
23" bays
www.adc.com
+1-952-938-8080
1-800-366-3891
19
DSXi Family
2.14 m
(7')
103253AE
DSX-1
658 mm
(25.9")
381 mm
(15")
DMB-78WC01
(Front View)
Ordering Information
Dimensions
(HxWxD)
Description
Catalog
Number
19" bay
Front cross-connect skeleton bay, empty
Accommodates up to (14) 102 mm (4") high
56-termination panels, 784 terminations
DMB-78WC02
DMB-78WC01
DMB-71WC02
DMB-71WC01
6/07
23" bays
www.adc.com
+1-952-938-8080
1-800-366-3891
20
DSXi Family
Rack Hardware
64 mm
(2.5")
2.14 m
(7')
381 mm
(15")
381 mm
(15")
127 mm
(5")
Ordering Information
Dimensions
(HxW)
Description
381 mm (15")
Deep System
Catalog Number
RAC-7C0539
RAC-7C0545
RAC-7C0810
6/07
103253AE
DSX-1
2.14 m
(7')
RAC-7C0551
RAC-7C0633
RAC-7C0639
RAC-7C0811
RAC-7C0645
2.14 m (7')
RAC-7B0162
www.adc.com
+1-952-938-8080
1-800-366-3891
21
DSXi Family
Rack Hardware
DSX-1
Ordering Information
Description
Dimensions (HxW)
Catalog Number
AC raceway
With outlet (2 per rack where outlets are required)
ACOK-PWNB
ACB-PWNB
AC-PWNB-RS2.5
AC-PWNB-RS5
AC-PWNB-RS10
Blank panels
WECO
6/07
103253AE
AC raceway filler
EIA
PWBP-2023
PWBP-4023
PWBP-6023
PWBP-8023
PWBP-1723
PWBP-3523
PWBP-5223
PWBP-7023
RINST-DSX7-PW
RINST-DSXRFL-PW
www.adc.com
+1-952-938-8080
1-800-366-3891
22
FlexDSX Family
103253AE
DSX-1
Tracer
Lamp
TL
TL
RET
RET
MON OUT
OUT
Front
-48V
RO
RO
XRO
XRO
XTO
XTO
TO
IN
TO
TI
TI
XTI
XTI
XRI
XRI
RI
RI
SG
SG
MON IN
-48V
RET Power
SG
Rear
TL
Cross
Connect
OUT
IN
T
OUT
R
T IN Equipment
R
T
R
T
6/07
Tracer
Lamp
TL
TL
RET
RET
MON OUT
Front
-48V
OUT
SG
SG
RO
RO
XRO
XRO
XTO
XTO
TO
IN
TO
TI
TI
XTI
XTI
XRI
XRI
RI
RI
MON IN
TL
Cross OUT
Connect
IN
-48V
RET Power
SG
Rear
T
OUT
R
T IN Equipment
R
T
R
T
R
www.adc.com
+1-952-938-8080
1-800-366-3891
23
FlexDSX Family
Four-Pack Module
FlexDSX four-pack module contains four
individual jack cards. IN/OUT equipment cable
terminations on the backplane maximize flexibility.
Chassis
The FlexDSX chassis is loaded with four-pack
modules. The fully loaded chassis system
simplifies ordering and minimizes expense.
FlexDSX Chassis
103253AE
DSX-1
Four-Pack Module
Skeleton Bay
6/07
www.adc.com
+1-952-938-8080
1-800-366-3891
24
FlexDSX Family
DFX-100084-R
(Front View)
DFX-100084-R
(Rear View)
Ordering Information
Terminations
Designation
84
1-84
Dimensions
(HxWxD)
Mounting
Options
Flush
Catalog Number
DFX-100084-R
6/07
103253AE
DSX-1
www.adc.com
+1-952-938-8080
1-800-366-3891
25
FlexDSX Family
DFX-100084
(Rear View)
Ordering Information
Cross-Connect
Terminations
Designation
84
1-84
Front
Dimensions
(HxWxD)
Mounting
Options
Flush
84-Termination Panel
Empty chassis
4-pack with jacks
Catalog
Number
DFX-100084
DFX-9T0001
DFX-9T1000
6/07
103253AE
DSX-1
www.adc.com
+1-952-938-8080
1-800-366-3891
26
FlexDSX Family
Ordering Information
Cross-Connect
Terminations
Designation
64
1-64
Mounting
Options
Flush
Catalog
Number
DFX-100064*
64-Termination Panel
Empty chassis
4-pack with jacks
DFX-9T0003
DFX-9T1000
6/07
103253AE
DSX-1
Front
Dimensions
(HxWxD)
www.adc.com
+1-952-938-8080
1-800-366-3891
27
FlexDSX Family
Ordering Information
Cross-Connect
Terminations
Designation
56
1-56
Mounting
Options
Flush
Catalog
Number
DFX-100056*
56-Termination Panel
DFX-9T0004
DFX-9T1000
6/07
103253AE
DSX-1
Front
Dimensions
(HxWxD)
www.adc.com
+1-952-938-8080
1-800-366-3891
28
FlexDSX Family
Features
Accommodates both the front and rear
cross-connect style FlexDSX chassis
23-inch WECO network-style rack
Equipped with fuse panel, upper and lower
horizontal jumper troughs, and vertical
jumper rings
Bay color: putty
Ordering Information
Dimensions
(HxWxD)
Catalog
Number
23" bays
Front cross-connect skeleton bay, empty
Acccomodates up to (10) 152 mm (6") high chassis;
840 terminations
DFX-B7S001
103253AE
DSX-1
Description
Rack Ground
Post Terminal
Power Wire
Bracket
35
51 mm (2")
Stand-Off
Bracket
6/07
Position 10
30
Position 9
Position 8
25
Position 7
Position 6
20
2.14 m
(7')
Position 5
15
Position 4
Position 3
10
Position 2
Lower
Cable
Trough
Position 1
114 mm
(4.50")
www.adc.com
658 mm
(25.9")
305 mm
(12")
Footprint
(Front View)
DFX-B7S001
(Side View)
Cable Ring
Welded On Trough
To Support
Crossing Cables
Between Bays
+1-952-938-8080
(Rear View)
1-800-366-3891
29
FlexDSX Family
Rack Hardware
64 mm
(2.5")
2.14 m
(7')
6/07
127 cm
(5")
305 mm
(12")
305 mm
(12")
Ordering Information
Dimensions
(HxW)
Description
305 mm (12")
Deep System
Catalog Number
7RFP-5NPW
RAC-7C0554
RAC-7C0353
103253AE
DSX-1
2.14 m
(7')
2.14 m (7')
7RFP-25NPW
UEGP-7PW
www.adc.com
+1-952-938-8080
1-800-366-3891
30
FlexDSX Family
Rack Hardware
DSX-1
Ordering Information
Description
Dimensions (HxW)
Catalog Number
AC raceway
With outlet (2 per rack where outlets are required)
ACOK-PWNB
ACB-PWNB
AC-PWNB-RS2.5
AC-PWNB-RS5
AC-PWNB-RS10
Blank panels
WECO
6/07
103253AE
AC raceway filler
EIA
PWBP-2023
PWBP-4023
PWBP-6023
PWBP-8023
PWBP-1723
PWBP-3523
PWBP-5223
PWBP-7023
RINST-DSX7-PW
RINST-DSXRFL-PW
www.adc.com
+1-952-938-8080
1-800-366-3891
31
FlexDSX Family
The FlexDSX super high-density bay achieves greater density in a 7' height x 26" width x 18.75" depth,
accommodating up to 1512 (7') usable DSX jack terminations. ADCs flexible ordering guide allows
bay designs in 64 or 84 jacks per panel. This eliminates jack waste or complications in circuit
management administration.
Features
Quick to install
Simplifies engineering
6/07
103253AE
DSX-1
The FlexDSX super high-density bay enables service providers to realize additional cost savings by
conserving valuable floor space. The bay provides more than 30% floor space savings, while doubling
the density and provides dual monitoring with ADCs reliable FlexDSX jack technology.
Cross-connect block design provides clear identification of each circuit by offering expanded labeling space
improving network documentation and decreasing potential mistakes while troubleshooting
Colored cross-connect labels allow for easy determination of circuit terminations
www.adc.com
+1-952-938-8080
1-800-366-3891
32
FlexDSX Family
6/07
103253AE
DSX-1
DFX-SHD001
(Front View)
Ordering Information
Jacks Per
# of
Panel
Terminations
Description
# of Tie Pair
Circuits
Catalog
Number
84
1512
160
DFX-SHD001
84
1512
160
DFX-SHD002
Overhead cabling
84
1344
160
DFX-SHD003*
84
1344
160
DFX-SHD004*
Overhead cabling denotes the cable enters the top of the bay and the equipment termination blocks are at the top
of the bay. Raised floor cabling denotes the cable enters from the raised floor into the bottom of the bay and the
equipment blocks are at the bottom of the bay.
*Maintenance bays are equipped with one 56-position interbay panel.
www.adc.com
+1-952-938-8080
1-800-366-3891
33
FlexDSX Family
Catalog Number
ACOK-PWNB
SHD-HR-85
RINST-FLR
Raised floor
SHD-HR-91
RINST-DSXRFL-PW
SHD-HR-44N
6/07
103253AE
DSX-1
Installation kits
www.adc.com
+1-952-938-8080
1-800-366-3891
34
Specialty Panels
DSX-1
Features
Increased modularity
Increased efficiency and flexibility
One panel meets DS1/3, fiber, and Ethernet
termination requirements
Interchangeable modules allow
maximum flexibility
- DS1
- DS3
- Fiber terminations
103253AE
- Ethernet modules
Compact size for standard mounting
- 5.25" high EIA
- 6" high WECO
Supports bidirectional testing
High-density
- 16 modules in 19" width
6/07
www.adc.com
+1-952-938-8080
1-800-366-3891
35
Specialty Panels
DSX-1
6/07
103253AE
DS1 Module
DS3 Module
Fiber Module
RJ Module
Ordering Information
Description
Dimensions (HxWxD)
Catalog Number
Panels
19" empty panel;
16 module capacity
DFX-9E0002
DFX-9T0001
Modules
DS1 module;
includes 4 jack cards with dual monitor
1 module width
DFX-9T1000
1 module width
DFX-D3000
2 module width
DFX-SC0002
1 module width
DFX-9RJ002
1 module width
DFX-9RJ006
www.adc.com
+1-952-938-8080
1-800-366-3891
36
Specialty Panels
Front View
Tracer LEDs eliminate manual tracing of crossconnect wires for fast circuit identification
6/07
103253AE
DSX-1
Rear View
Ordering Information
Circuit
Density
Dimensions
(HxWxD)
28
D1M-1X0012*
84 DS1
18 DS3
DIM1X0027
28
D1M-1A0042
4 midsize
jacks
D3M-XRMC11
4
standard
size jacks
D3M-XRSC11
1 DS3
DSX-4H-MBRC-BA
6 DS3
DSX4H-6HDSL
84 DS1
3 DS3
D1M-1A0060
Description
Catalog Number
Chassis
Modules
DS1 module; mounts into
D1M-1X0012 chassis;
1-14, 15-28 designation
* Chassis has three total module positions. One 28-termination module is included. The two additional modules
are ordered separately.
www.adc.com
+1-952-938-8080
1-800-366-3891
37
Features
Cost-effective solution for applications where
circuit reconfiguration is infrequent
Creates permanent, dedicated connection
between two network elements to the DSX
interface
Application
DSX-1
Network
Element
Network
Element
MON
OUT
Tx OUT
Permanent
Equipment
Cables
Rx IN
IN
Permanent
Equipment
Cables
IN
OUT
Rx IN
Tx OUT
103253AE
MON
Permanent
Equipment Cable
To Network
Element B
6/07
Permanent
Equipment
Cable
To Network
Element A
www.adc.com
+1-952-938-8080
1-800-366-3891
38
D1M-1E1101
(Front View)
Ordering Information
Circuit Density
Number of
Terminations
56
112
Designation
Dimensions
(HxWxD)
Mounting
Options
1-56 A
1-56 Z
Flush
Catalog
Number
D1M-1E1101
6/07
103253AE
DSX-1
D1M-1E1101
(Rear View)
www.adc.com
+1-952-938-8080
1-800-366-3891
39
The digital distribution point (DDP-1) chassis is an interface point placed between a digital cross-connect
system (DCS) and digital NEs, providing a flexible alternative to hard wiring NEs directly to the DCS.
A digital distribution point provides cable termination and circuit access to digital circuits at the DS1,
DS1C, E1 and VT1.5 signal levels. Software cross-connects between two NEs are provided by the DCS.
The DDP-1 chassis is available in a single access configuration. Various circuit densities are available to
match DCS group quantities; i.e., 56-, 84-circuit. Various wiring connection styles; i.e., wire-wrap, 50-pin
or 64-pin connectors and equipment rack styles; i.e., 19-inch, 23-inch mounting are available.
Single-Access Chassis
The single-access chassis allows access to the NE side or the DCS side but not simultaneously. An access
card is inserted in the normal position (with monitor jack on top) to access the NE. The access card is
inserted in the inverted position (monitor jack on bottom) to access the DCS.
DSX-1
Features
A cost-effective alternative to hardwiring digital equipment directly to the 1/3 DCS backplane
Smooth, flexible and economical migration of service to a 1/3 DCS in an office
In-service or out-of-service cutover options using DDP-1
Catastrophic access options utilizing the optional jack access card (monitoring in
both directions from one location and patching options)
Superior cable management and additional cabling flexibility as the office grows
Economical access solution since permanent jacks are not required for each circuit
DDP-1
DDP-3
DS1
NE
103253AE
6/07
DS1
NE
Twisted Pair
Cable
DS1
PORT
DS3
PORT
DS1
PORT
DS3
PORT
DS3
NE
DS3
NE
Coaxial
Cable
1/3 DCS
DDP-1 POS #1
DS1
NE1
XMIT
RCV
Chassis
M
DS1
NE1
DCS Access
XMIT
RCV
DCS
DS1
XMIT
PORT RCV
A
Software
Cross-Connects
DS1
NE2
DCS
DS1
PORT
A
DS1
PORT XMIT
RCV
B
O
XMIT
RCV
O
I
NE Access
DCS Access
XMIT
RCV
DDP-1 POS #2
Software
Cross-Connects
to Other DCS Ports
www.adc.com
+1-952-938-8080
1-800-366-3891
40
DD1-351001
(Front View with
Door Closed)
DD1-351001
(Rear View)
Ordering
Number of
Circuits
84
584 mm
(23)
In
fo
rmation
566
mm
(22.3)
Cable
Connections
DCS IN/OUT
Cable
Connections
NE IN/OUT
Wire-wrap
Wire-wrap
Cable
Termination Mounting
Access 152 mm
Options
Rear
44 mm
(1.75)
(6)
Flush or 2"
recess
WECO/EIA
Dimensions
(HxWxD)
152 mm x 584 mm
x 213 mm
(6" x 23" x 8.4")
Catalog
Number
DD1-351001
6/07
103253AE
DSX-1
DD1-351001
(Front View with
Door Open)
584 mm
(23)
566 mm
(22.3)
NETWORK
ELEMENT
152 mm
(6)
DD1-351001
(Rear View)
DD1-351001
(Front View with
Door Open)
44 mm
(1.75)
NETWORK
ELEMENT
www.adc.com
+1-952-938-8080
1-800-366-3891
41
DD1-311001
(Front View with
Door Closed)
DD1-311001
(Front View with
Door Open)
Ordering Information
Cable
Connections
DCS IN/OUT
Cable
Connections
NE IN/OUT
Cable
Termination
Access
56
Wire-wrap
Wire-wrap
56
Wire-wrap
Wire-wrap
Number
of Circuits
Mounting
Options
Dimensions
(HxWxD)
Catalog
Number
Rear
Flush or
51 mm (2")
recess
WECO/EIA
66 mm x 584 mm x
203 mm
(2.6" x 23" x 8")
DD1-311001
Rear
121 mm
(4.75")
recess
WECO/EIA
76 mm x 482 mm x
292 mm
(3" x 19" x 11.5")
DD1-211001
6/07
103253AE
DSX-1
DD1-311001
(Rear View)
203 mm
(8")
31.8 mm
(1.25")
31.8 mm
(1.25")
CKT 1
51 mm
(2")
DD1-311001
(Top View)
566 mm
(22")
584 mm
(23")
CKT 56
66 mm
(2.6")
31.8 mm
(1.25")
DD1-311001
(Front View)
www.adc.com
+1-952-938-8080
1-800-366-3891
42
Cards are inserted into the DDP-1 chassis only when equipment installation or maintenance activities are
required. A variety of cards provide many functions during installation and maintenance activities. Each
access card has a lock and release device for secure attachment in the chassis. All cards containing jacks
use industry-standard bantam jacks.
Description
Catalog Number
Loopback card; provides loopback of transmit to receive for both the NE and DCS
equipment
DD1-100002
Terminating card; provides 135 Ohm termination across tip and ring for transmit and
receive of both NE and DCS equipment
DD1-100003
Opening card; provides opening of transmission path between NE and DCS (isolates NE
from DCS for continuity testing during installation)
DD1-100004
Jack access card; provides MON, OUT and IN jacks for circuit access to NE equipment and
provides MON, OUT and IN jacks for circuit access to DCS equipment
DD1-100005
Drop and insert card; provides MON, OUT and IN jacks for both the NE and DCS
equipment for full duplex circuit access. This provides dual access functionality in
the single access chassis
DD1-100006
Circuit guard card; provides circuit guard with red label for a single mounting slot
within the chassis. This prevents insertion of an access card for high priority circuits
DD1-100008
Monitor only card; provides MON jack for circuit access to the NE equipment transmit
and provides MON jack for circuit access to the DCS equipment transmit when the card is
inverted
DD1-100012
DSO access card; provides jack access to voice frequency circuits when DDP-1 chassis is
used in special analog applications
DD1-100020
DD1-100025
Module extractor tool; used to extract DDP-1 card from its mounting slot in the chassis
DD1-000001
6/07
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
43
Auxiliary Equipment
Cross Aisle Panels
Cross aisle panels are placed in nonadjacent DSX-1 environments, such as multiple bay lineups, multiple
floor locations, customer hand-off interface locations, etc. The cross aisle panels are connected to
each other by permanent tie cables. When service is required between the two environments, a
semi-permanent cross-connect jumper is run between the DSX-1 module and the cross aisle
panel in each environment to complete the circuit path.
Features
Keep jumpers accessible for reconfiguration
Application
Network
Element
Cross
Aisle
Panel
DSX-1
Tx OUT
Cross
Aisle
Panel
MON
OUT
IN
Rx IN
Tx OUT
OUT
IN
Rx IN
Cross-Connect
Jumper
Cross-Connect
Jumper
DSX-1 Lineup #1
6/07
Network
Element
DSX-1
Cross
Aisle
Tie
Cable
MON
103253AE
DSX-1
DSX-1 Lineup #2
Cross Aisle
Tie Cables
Cross
Aisle
Panels
To Network
Element
A
Permanent
Equipment
Cable
To Network
Element
B
DSX Lineup #1
Cross-connect
Jumper
Permanent
Equipment
Cable
DSX Lineup #2
www.adc.com
+1-952-938-8080
1-800-366-3891
44
Auxiliary Equipment
Cross Aisle Panels
Features
Color-coded wire-wrap terminals
Wire fanning strips located below terminals
Flush or 2-inch recess mounting available
DSX-CAP-BEST
(Front View)
Ordering Information
Designation
Dimensions
(HxW)
Jumper
Rings
Color
Catalog Number
100 5-wire
terminations,
with LED
1-100
102 mm x 584 mm
(4" x 23")
102 mm x 102 mm
(4" x 4")
cable rings
Putty
DSX-CAP-BEST
100 5-wire
terminations
with rear 50-pin
AMP IN/OUT
connectors
1-100
102 mm x 584 mm
(4" x 23")
102 mm x 102 mm
(4" x 4")
cable rings
Putty
DSX-CAP-BEST/CONN
200 5-wire
terminations
1-50A, 1-50B,
1-50C, 1-50D
102 mm x 584 mm
(4" x 23")
102 mm x 102 mm
(4" x 4")
cable rings
Putty
DSX-CAP-D-PWT-4CR
200 5-wire
terminations
1-50A, 1-50B,
1-50C, 1-50D
127 mm x 584 mm
(5" x 23")
102 mm x 127 mm
(4" x 5")
cable rings
Putty
DSX-CAP-D-PWT-5CR
80-circuit, 5-wire
terminations
1-80
762 mm x 584 mm
(3" x 23")
102 mm x 102 mm
(4" x 4")
cable rings
Putty
DSX-CAP-BEST/80
240-circuit, 5-wire
terminations
1-240
177.8 mm x 584 mm
(7" x 23")
102 mm x 102 mm
(4" x 4")
cable rings
Putty
DSX-CAP-BEST/240
6/07
103253AE
DSX-1
Circuit Density
www.adc.com
+1-952-938-8080
1-800-366-3891
45
Auxiliary Equipment
Interbay Patch Panels
In lengthy or multiple DSX bay lineups, the interbay patch panel provides a means of extending a
standard-length patch cord. The interbay patch panel is hardwired, daisy-chain style, circuit to circuit.
Patches are made from the DSX port-of-signal origin to the nearest interbay panel. The signal is then
transmitted via hardwire connections, in the interbay panel, to the closest interbay panel at the other
end. A second patch is made from this interbay panel to the DSX jack. The LED stays lit when the circuit
is in use.
Application
Network
Element
Interbay
Patch
Panel
DSX-1
Interbay
Patch
Panel
MON
OUT
IN
Network
Element
MON
Interbay
Tie
Cable
OUT
IN
Rx IN
OUT
IN
Patch cords
Tx OUT
OUT
IN
Rx IN
Patch cords
DSX-1 Lineup #1
DSX-1 Lineup #2
Short
Patch
Cord
To
Network
Element
A
6/07
103253AE
DSX-1
Tx OUT
DSX-1
Short
Patch
Cord
To
Network
Element
B
Maintenance
Bay
DSX Lineup #1
DSX Lineup #2
www.adc.com
+1-952-938-8080
1-800-366-3891
46
Auxiliary Equipment
Interbay Patch Panels
Features
Bantam jack terminations
Rear wire-wrap terminals
Red tracer LEDs
Panel color: black
DSX-IB-23A
Circuit
Density
Number of
Termination
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
25 Left
25 Right
50
89 mm x 483 mm x 203 mm
(3.5" x 19" x 8")
Flush
25 Left
25 Right
50
Flush,
102 mm x 127 mm
(4", 5") recess
DSX-IB-23A
28 Left
28 Right
56
89 mm x 584 mm x 203 mm
(3.5" x 23" x 8")
Flush
DSX-IB-23B
DSX-IB-19
6/07
103253AE
DSX-1
Ordering Information
www.adc.com
+1-952-938-8080
1-800-366-3891
47
Auxiliary Equipment
Bay Tracer Illuminator
Features
Big savings for big lineups
Immediate savings
Easy to install
Easy to see
6/07
103253AE
DSX-1
90 second timer
44 mm
(1.75")
Reset feature
108 mm
(4.25")
76 mm
(3.00")
Application
The unit is automatically activated through the
DSX fuse panel whenever an individual tracer
LED is activated. After a 90-second flashing cycle,
the Bay Tracer will turn off until the next tracer
event. The DSX jack LED flashes for 30 seconds
and then stays lit, as before, until a technician
deactivates the LED.
Ordering Information
Description
Catalog Number
AUX-BT0001
AUX-BTLF01
PWBP-8023BT
AUX-0X6671
AUX-0X6672
AUX-0X6673
www.adc.com
+1-952-938-8080
1-800-366-3891
48
Auxiliary Equipment
DS1 Repeaters
DSX-1
DSX-1
Bay
Up To 200 m
(655')
DS-1 Dual
I/O Repeater
Up To 200 m
(655')
DSX
DSX
Up To 200 m
(655')
MUX OR
Digital
Switch
6/07
103253AE
www.adc.com
+1-952-938-8080
1-800-366-3891
49
Auxiliary Equipment
DS1 Repeaters
6/07
103253AE
DSX-1
Ordering Information
Dimensions
(HxWxD)
Description
Dual intraoffice repeater card
T1 (1.544 Mbps)
Rack-mounted chassis
28-position, empty; wire-wrap signal connection, wirewrap terminal power and alarm connections
94 mm x 257 mm
(3.7" x 10.1")
102 mm x 584 mm x 292 mm
(4" x 23" x 11.5")
Catalog
Number
T1544-00E
IOR-MA4280
Ordering Information
Dimensions
(HxWxD)
Description
Dual bridging office repeater card
T1 (1.544 Mbps)
Rack-mounted chassis
28-position, empty; wire-wrap signal connection,
wire-wrap terminal power and alarm connections
www.adc.com
+1-952-938-8080
94 mm x 257 mm
(3.7" x 10.1")
102 mm x 584 mm x 292 mm
(4" x 23" x 11.5")
1-800-366-3891
Catalog
Number
T1544-11B
IOR-MA4280
50
Auxiliary Equipment
Communications Panels
Features
Touch key access to nine dial lines; lines 8
and/or 9 may be changed to signaling or
intercom mode by switch setting
6/07
103253AE
DSX-1
Ordering Information
Dimensions
(HxWxD)
Catalog
Number
Communications panel
Touch key access to 9 dial lines (POTS or 1A2 key
telephone) or 7 dial lines and any combination of 2 office
intercom and signal lines along with hold, conferencing
and on-hook features; access to dial and intercom lines
is via jack connected to 52-type headset or equivalent
telephone set; comes with reversible mounting ears for
19" or 23" (483 mm or 584 mm) racks.
COMP-21
Communications panel
Includes all same features as COMP-21. Equipped with
remote headset extension jack circuit. 9 touch keys that
permit remote headset extension jacks to be connected
to any telephone line key position while allowing the
panel to be free for use on other telephone or intercom
lines; comes with reversible mounting ears for 19" or 23"
(483 mm or 584 mm) racks.
COMP-11
89 mm x 450 mm x 127 mm
(3.5" x 17.7" x 5")
COMP-31
Description
www.adc.com
+1-952-938-8080
1-800-366-3891
51
Auxiliary Equipment
Catalog Number
COMP-HDS
COMP-HNDSKIT
COMP-HNR-P
HSE-100001
Allows daisy chaining COMP-11, 21, 31 to older 660 style communications panels
COMP-CNVN CORD
Allows daisy chaining COMP-11, 21, 31 to Porta type 925 communications panels
COMP-CNVN PORTA
Writing Shelves
Retractable writing shelves provide a writing
surface during maintenance activities. The shelves
are usually mounted at arm level on the bay for
easily accessible writing space.
RWS23
Ordering Information
Dimensions
(HxWxD)
Description
Retractable writing shelf
Color
Catalog Number
44 mm x 584 mm x 290 mm
(1.75" x 23" x 11.4")
Gray
RWS23
44 mm x 483 mm x 290 mm
(1.75" x 19" x 11.4")
Gray
RWS19
44 mm x 584 mm x 290 mm
(1.75" x 23" x 11.4")
Putty
RWS23-PUT
44 mm x 584 mm x 290 mm
(1.75" x 23" x 11.4")
Black
RWS23-BLK
6/07
103253AE
DSX-1
Cable assembly
www.adc.com
+1-952-938-8080
1-800-366-3891
52
Auxiliary Equipment
Fuse Panels
Primarily used to power LEDs in DSX modules, fuse panels are also used to power auxiliary equipment
such as intraoffice and bridging repeaters and communication panels.
Features
NEBS Level 3, UL, NEC 1999 and CSA compliant
Ordering Information
Description
Dimensions (HxW)
45 mm x 483/584 mm
(1.75" x 19"/23")
103253AE
Input power:
Bus amperage:
Remote alarm contact (resistive load):
Local alarm indicator:
GMT Fuses:
GMT Fuses
6/07
Catalog Number
PDP-FPCS201PWWXX
Specifications
DSX-1
ELECTRICAL
-42 to -56 Vdc (no strapping required)
60 Amps maximum per bus
125V maximum
LED
3 Amps maximum per fuse
Ordering Information
Catalog Number
Catalog Number
with Pin Identifier
Blue
F-3
P-3
Description
Amperage
Fuse Color
GMT Fuses
www.adc.com
Orange
F-2
P-2
1 - 1/3
White
F-1 1/3
P-1 1/3
Gray
F-1
P-1
3/4
Brown
F-3/4
P-3/4
1/2
Red
F-1/2
P-1/2
1/4
Violet
F-1/4
P-1/4
Dummy fuse
N/A
GMT-DUMMY
N/A
+1-952-938-8080
1-800-366-3891
53
Auxiliary Equipment
Cable troughs are used for horizontal cable management. Generally two cable troughs are required,
one at the top and one at the bottom of each rack.
AUX-2D0025
(Figure 2)
DSX-CT-23H
(Figure 1)
6/07
103253AE
DSX-1
Ordering Information
Dimensions
(HxWxD)
Description
Horizontal cable trough
Rounded bottom edges ensure proper coaxial cable
bend radius (see figure 1)
Catalog Number
AUX-2D0010
AUX-2D5010
AUX-2D0009
AUX-2D0006
AUX-2D0012
DSX-CT-23H
AUX-2D0026
AUX-2D0025
AUX-2D0028
AUX-2D0034
AUX-2D0031
AUX-2D0027
AUX-2D0033
AUX-2D0037
www.adc.com
+1-952-938-8080
1-800-366-3891
54
Accessories
Bantam Plugs
Terminating Plugs
The bantam terminating plug is used to terminate a circuit with a specific load. It has an integrated 0.5
watt 1 percent resistor. The plug shell is marked with the resistance value. Other resistance values
available on special order.
6.35 mm
(.250")
11.18 mm
(.44")
29.06 mm
(1.144")
7.24 mm
(.285")
4.39 mm
(.173")
51.71 mm
(2.036")
81.36 mm
(3.203")
.5 mm (.02'')
21.97 mm
(.865")
12.7 mm
(.5")
34.67 mm
(1.365")
Looping Plugs
Bantam looping plugs are used to loop OUT
jacks to IN jacks at the DSX. The plug conductors
are strapped internally. The three-conductor plugs
are wired tip to tip, ring to ring and sleeve to
sleeve.
7.92 mm
(.312")
21.97 mm
(.865")
44.45 mm
(1.75")
66.67 mm
(2.625")
Looping Plug
Hole Plugs
Dummy Plugs
19.84 mm
6.10 mm DIA
(.24")
6/07
103253AE
DSX-1
Terminating Plug
7.92 mm
(.312")
DIA
21.97 mm
(.865")
21.84 mm
(.860")
7.88 mm
(.31")
DIA
Hole Plug
Three-Conductor
Conversion Plugs
13.97 mm
(.55")
6.35 mm
(.25")
30.71 mm
(1.209")
86.51 mm
(3.406")
Conversion plugs provide a means to interface longframe [310] jacks to bantam
jacks. The rear of the
longframe plug is modified to accept either two-conductor or three-conductor bantam plugs.
13.97 mm
(.55")
6.35 mm
(.25")
30.71 mm
(1.209")
11.18 mm
(.44")
6.35 mm
(.25")
29.06 mm
(1.144")
86.51 mm
(3.406")
81.36 mm
(3.203")
11.18 mm
(.44")
6.35 mm
(.25")
29.06 mm
(1.144")
www.adc.com
81.36 mm
(3.203")
+1-952-938-8080
1-800-366-3891
55
Accessories
Bantam Plugs
Features
Single circuit guard plugs identify and block
7.37 mm
(.290")
DIA.
4.65 mm
(.183")
DIA.
DSX-1
12.19 mm
(.480")
5.59 mm
(.22")
Single
103253AE
7.92 mm
(.312")
3.81 mm
(.15")
4.06 mm
(.160")
TYP. (2)
15.49 mm
(.610")
7.92 mm
(.312")
3.81 mm
(.15")
12.19 mm
(.480")
15.49 mm
(.610")
6/07
6.67 mm
(.266")
Quad
1.27 mm
(.05")
4.65 mm
(.183")
7.92 mm
(.312")
15.54 mm
(.612")
3.81 mm
(.15")
1.27 mm
(.05")
11.81 mm
(.465")
1.52 mm
(.06")
3.56 mm
(.14")
6.67 mm
(.266")
Dual
www.adc.com
+1-952-938-8080
1-800-366-3891
56
Accessories
Bantam Plugs
Ordering Information
Description
Catalog Number
Terminating plugs
100 Ohm (actual resistor value: 100 Ohm, 1%)
PJ800
PJ744
PJ743
PJ749
PJ801
PJ802
PJ806
Two-conductor
PJ745
Three-conductor
PJ746
Hole plugs
Black
PJ729B
Red
PJ729R
PJ748
AP051
PJ925R
White
PJ925W
Red
PJ926R
PJ926W
6/07
103253AE
DSX-1
Looping plugs
Black
PJ926B
PLG-100051
White
PLG-100052
Black
PLG-100050
www.adc.com
+1-952-938-8080
1-800-366-3891
57
Accessories
Patch Cords
Three-Conductor
Bantam patch cords are plastic jacketed, shielded
cords with molded-on plugs and molded
insulation between conductors. The patch cords
are available with single and dual three-conductor
plugs. A cord strain relief feature is included in
the plug construction. Dual twisted pair patch
cords are recommended for protection against
crosstalk, especially during switch cutovers and
when patch cords over 12 feet are used.
Three-Conductor Single Patch Cord
(PJ722)
Ordering Information
Description
Length
(1')
PJ712
.92 m
(3')
PJ716
1.83 m
(6')
PJ722
3.05 m
(10')
PJ1210
3.66 m
(12')
PJ1212
4.58 m
(15')
PJ1415
6.1 m
(20')
PJ1420
7.63 m
(25')
PJ1425
9.15 m
(30')
PJ1430
15.25 m (50')
PJ1450
.3 m
(1')
PJ762
.92 m
(3')
PJ766
1.83 m
(6')
PJ772
3.05 m
(10')
PJ1310
2.66 m
(12')
PJ1312
6.1 m
(20')
PJ1520
7.63 m
(25')
PJ1525
9.15 m
(30')
PJ1530
103253AE
DSX-1
.3 m
6/07
Three-conductor
single
Catalog
Number*
Three-conductor
dual
Three-conductor
dual
(twisted pair)
15.25 m (50')
PJ1550
.92 m
(3')
PJ1303TP
4.58 m
(15')
PJ1315TP
6.1 m
(20')
PJ1320TP
7.63 m
(25')
PJ1325TP
4.39 mm
(.173")
44.45 mm MAX
(1.75")
7.80 mm
(.307")
Single Plug
7.92 mm
(.312")
21.97 mm
(.865")
44.45 mm MAX
(1.75")
Dual Plug
www.adc.com
+1-952-938-8080
1-800-366-3891
58
Accessories
Patch Cords
Conversion
Bantam conversion patch cords are manufactured
to interface longframe [310] jacks to bantam
jacks when patching and testing circuits.
6.35 mm DIA
(.25")
82.55 mm
(3.25")
Ordering Information
Description
Length
Dual conversion
Catalog
Number
1.83 m (6')
PJ946
3.66 m (12')
PJ952
6.10 m (20')
PJ1920
7.63 m (25')
PJ1925
9.15 m (30')
PJ1930
2.44 m (8')
PJ694
3.66 m (12')
PJ696
66.68 mm
(2.625")
44.45 mm MAX
(1.75")
6.35 mm
(.25")
7.92 mm
(.312")
103253AE
DSX-1
Single conversion
4.42 mm DIA.
(.174")
96.01 mm MAX
(3.78")
6/07
www.adc.com
+1-952-938-8080
1-800-366-3891
59
Accessories
44.20 mm
(1.74")
Lead Wires
7.24 mm
(0.285")
4.39 mm
(0.173")
Alligator
Clips
Bantam
Three-Conductor Plug
254 mm
(10")
Length
11.94 mm
(0.47") DIA.
21.97 mm
(0.865")
6/07
44.45 mm
(1.75")
7.24 mm
(0.285")
EZ Hook
Plugs
4.39 mm
(0.173")
Bantam
Three-Conductor Plug
152.4 mm
(6")
Length
35.81 mm
(1.41")
57.15 mm
(2.25")
1.468"
(37.29 mm)
103253AE
DSX-1
These patch cords incorporate EZ Hook prongs on one end of a patch cord and either bantam or
longframe plugs on the other end.
4.39 mm
(0.173")
www.adc.com
62.23 mm
(2.45")
Bantam
Three-Conductor Plug
41.28 mm
(1.625")
7.92 mm
(.312")
+1-952-938-8080
1873.25 mm
(73.75")
34.93 mm
(1.375")
Banana
Type Plug
1-800-366-3891
60
Accessories
7.24 mm
(0.285")
44.45 mm
(1.75")
3.81 mm
(.150")
BnC
4.39 mm
(0.173")
length
Bantam
three-Connector Plug
21.97 mm
(0.865")
7.24 mm
(0.285")
44.20 mm
(1.74")
RJ11 Telephone
Plug
4.39 mm
(0.173")
Bantam
Three-Conductor Plug
Length
44.96 mm
(1.770")
6/07
Bantam
Three-Conductor Plug
www.adc.com
Tip
(Far Side)
Length
103253AE
DSX-1
These patch cords incorporate a two-conductor RJ11 telephone plug on one end of a patch cord and a
single bantam three-conductor plug on the other end.
Ring
(Far Side)
7.62 mm
(0.300")
+1-952-938-8080
Shield
1-800-366-3891
61
Accessories
Length
1.83 m (6')
CCCDSMB02
2.44 m (8')
CCCDSMB03
3.05 m (10')
CCCDSMB04
1.83 m (6')
PAT-106630
1.53 m (5')
PAT-100079
2.14 m (7')
LPC001
1.83 m (6')
PAT-100654
.915 m (3')
PAT-005
1.53 m (5')
PAT-006
2.44 m (8')
PAT-007
1.83 m (6')
BJR2M6
.915 m (3')
PAT-100092
1.83 m (6')
PAT-100093
3.66 m (12')
PAT-100094
.915 m (3')
PAT-100096
1.83 m (6')
PAT-100097
3.66 m (12')
PAT-100098
6/07
103253AE
DSX-1
Catalog Number
www.adc.com
+1-952-938-8080
1-800-366-3891
62
Accessories
Patch Cords
Accessory Kits
Bantam accessory kits include bantam patch
cords, plugs and terminating plugs to
simplify ordering.
Ordering Information
Catalog
Number
6/07
103253AE
DSX-1
Description
Accessory kit 1 includes:
1 600 Ohm terminating plug
4 135 Ohm terminating plug
1 900 Ohm terminating plug
10 Single red circuit guard
3 1.2 m (4') single patch cord
3 1.2 m (4') dual patch cord
2 1.8 m (6') single patch cord
2 1.8 m (6') conversion patch cord
(PJ743)
(PJ744)
(PJ749)
(PJ925R)
(PJ718)
(PJ768)
(PJ722)
(PJ946)
(PJ743)
(PJ744)
(PJ749)
(PJ925R)
(PJ746)
(PJ748R)
(PJ718)
(PJ768)
(PJ722)
(PJ772)
(PJ1208)
(PJ1308)
(PJ948)
(PJ743)
(PJ744)
(PJ749)
(PJ925R)
(PJ746)
(PJ748R)
(PJ722)
(PJ772)
(PJ1208)
(PJ1308)
(PJ948)
(PJ1210)
(PJ1310)
www.adc.com
ACK-1
ACK-2
ACK-3
+1-952-938-8080
1-800-366-3891
63
Accessories
Patch Cords
6/07
103253AE
DSX-1
Ordering Information
Description
Catalog Number
ACK-CEV-1
ACK-CEV-2
www.adc.com
+1-952-938-8080
1-800-366-3891
64
Accessories
Cross-Connect Wire
6/07
103253AE
DSX-1
tracer identification
Ordering Information
Description
Catalog Number
Cross-connect wire
152 m (500') roll
DSX-CCW/500
DSX-CCW/1000
DSX-CCW/2000
AUX-0X6667
Catalog Number
AUX-0X0165
AUX-0X0800
www.adc.com
+1-952-938-8080
1-800-366-3891
65
Accessories
Ordering Information
Description
Catalog Number
DSX-1
FLEDR
Green
FLEDG
Yellow
FLEDY
Orange
FLEDO
FLEDR1
Green
FLEDG1
Yellow
FLEDY1
Orange
FLEDO1
Di-FLEDR
6/07
103253AE
www.adc.com
+1-952-938-8080
1-800-366-3891
66
Index
Symbols
7RFP-25NPW...............................................30
7RFP-5NPW.................................................30
6/07
103253AE
DSX-1
A
AC-PWNB-RS2.5....................................22, 31
AC-PWNB-RS5.......................................22, 31
AC-PWNB-RSID............................................22
ACB-PWNB............................................22, 31
ACK-1.........................................................63
ACK-2.........................................................63
ACK-3.........................................................63
ACK-CEV-1..................................................64
ACK-CEV-2..................................................64
ACOK-PWNB...................................22, 31, 34
AL-PWNB-RS10............................................31
AP051.........................................................57
AUX-0X0165...............................................65
AUX-0X0800...............................................65
AUX-0X6667...............................................65
AUX-0X6671...............................................48
AUX-0X6672...............................................48
AUX-0X6673...............................................48
AUX-2D0006...............................................54
AUX-2D0009...............................................54
AUX-2D0010...............................................54
AUX-2D0012...............................................54
AUX-2D0025...............................................54
AUX-2D0026...............................................54
AUX-2D0027...............................................54
AUX-2D0028...............................................54
AUX-2D0031...............................................54
AUX-2D0033...............................................54
AUX-2D0034...............................................54
AUX-2D0037...............................................54
AUX-2D5010...............................................54
AUX-BT0001................................................48
AUX-BTLF01................................................48
B
BJR2M6.......................................................62
C
CCCDSMB02...............................................62
CCCDSMB03...............................................62
CCCDSMB04...............................................62
COMP-11....................................................51
COMP-21....................................................51
COMP-31....................................................51
COMP-CNVNCORD......................................52
COMP-HDS..................................................52
www.adc.com
+1-952-938-8080
COMP-HNDSKIT...........................................52
COMP-HNR-P...............................................52
D
D1M-1A0042..............................................37
D1M-1A0060..............................................37
D1M-1E1101...............................................39
D1M-1X001.................................................37
D1M-1X0012...............................................37
D3M-XRMC11.............................................37
D3M-XRSC11..............................................37
DD1-000001................................................43
DD1-100002................................................43
DD1-100003................................................43
DD1-100004................................................43
DD1-100005................................................43
DD1-100006................................................43
DD1-100008................................................43
DD1-100012................................................43
DD1-100020................................................43
DD1-100025................................................43
DD1-211001................................................42
DD1-311001................................................42
DD1-351001................................................41
DFX-100056*..............................................28
DFX-100064*..............................................27
DFX-100084................................................26
DFX-100084-R.............................................25
DFX-9E0002................................................36
DFX-9RJ002.................................................36
DFX-9RJ006.................................................36
DFX-9T0001..........................................26, 36
DFX-9T0003................................................27
DFX-9T0004................................................28
DFX-9T1000..............................26, 27, 28, 36
DFX-B7C002................................................29
DFX-B7S001................................................29
DFX-D3000..................................................36
DFX-SC0002................................................36
DFX-SHD001................................................33
DFX-SHD002................................................33
DFX-SHD003................................................33
DFX-SHD004................................................33
Di-A2CU1....................................................12
Di-A2GU1....................................................12
Di-A3CU1....................................................12
Di-A3GU1....................................................12
Di-D2CU1....................................................11
Di-D2GU1....................................................11
Di-F2CU1.....................................................10
Di-F2GU1.....................................................10
Di-FLEDR......................................................66
1-800-366-3891
67
6/07
103253AE
DSX-1
Index
Di-G2CU1....................................................10
Di-G2GU1....................................................10
Di-G3CU1....................................................10
Di-G3GU1....................................................10
Di-H2CU1....................................................15
Di-H2GU1....................................................15
Di-H3CU1....................................................15
Di-H3GU1....................................................15
Di-K2CU1....................................................14
Di-K2GU1....................................................14
Di-M2CU1...................................................13
Di-M2GU1...................................................13
Di-M3CU1...................................................13
Di-M3GU1...................................................13
Di-N2CU1....................................................15
Di-N2GU1....................................................15
Di-N3CU1....................................................15
Di-N3GU1....................................................15
Di-R2CU1....................................................14
Di-R2GU1....................................................14
Di-T2CU1.....................................................13
Di-T2GU1....................................................13
Di-U2CU1....................................................18
Di-U2GU1....................................................18
Di-W2CU1...................................................17
Di-W2GU1...................................................17
Di-X2CU1....................................................16
Di-X2GU1....................................................16
DIM1X0027...............................................37
DMB-71WC01.............................................20
DMB-71WC02.............................................20
DMB-72WC01.............................................19
DMB-72WC02.............................................19
DMB-77WC01.......................................19, 29
DMB-77WC02.............................................19
DMB-78WC01.............................................20
DMB-78WC02.............................................20
DSX-4H-MBRC-BA.......................................37
DSX-6HDSL..................................................37
DSX-CAP-BEST.............................................45
DSX-CAP-BEST/240......................................45
DSX-CAP-BEST/80........................................45
DSX-CAP-BEST/CONN..................................45
DSX-CAP-D-PWT-4CR..................................45
DSX-CAP-D-PWT-5CR..................................45
DSX-CCW/1000...........................................65
DSX-CCW/2000...........................................65
DSX-CCW/500.............................................65
DSX-CT-23H.................................................54
DSX-IB-19....................................................47
DSX-IB-23A..................................................47
DSX-IB-23B..................................................47
www.adc.com
+1-952-938-8080
DSX4H-GHDSL.............................................37
F
F-1...............................................................53
F-1/2............................................................53
F-1/4............................................................53
F-1 1/3.........................................................53
F-2...............................................................53
F-3...............................................................53
F-3/4............................................................53
FLEDG..........................................................66
FLEDG1........................................................66
FLEDO..........................................................66
FLEDO1........................................................66
FLEDR..........................................................66
FLEDR1........................................................66
FLEDY..........................................................66
FLEDY1........................................................66
G
GMT-DUMMY..............................................53
H
HSE-100001................................................52
I
IOR-MA4280...............................................50
L
LPC001........................................................62
N
N/A..............................................................53
P
P-1...............................................................53
P-1/2............................................................53
P-1/4............................................................53
P-1 1/3.........................................................53
P-2...............................................................53
P-3...............................................................53
P-3/4............................................................53
PAT-005.......................................................62
PAT-006.......................................................62
PAT-007.......................................................62
PAT-100079.................................................62
PAT-100092.................................................62
PAT-100093.................................................62
PAT-100094.................................................62
PAT-100096.................................................62
1-800-366-3891
68
6/07
103253AE
DSX-1
Index
PAT-100097.................................................62
PAT-100098.................................................62
PAT-100654.................................................62
PAT-106630.................................................62
PDP-FPCS201PWWXX..................................53
PJ1208.........................................................63
PJ1210...................................................58, 63
PJ1212.........................................................58
PJ1303TP.....................................................58
PJ1308.........................................................63
PJ1310...................................................58, 63
PJ1312.........................................................58
PJ1315TP.....................................................58
PJ1320TP.....................................................58
PJ1325TP.....................................................58
PJ1415.........................................................58
PJ1420.........................................................58
PJ1425.........................................................58
PJ1430.........................................................58
PJ1450.........................................................58
PJ1520.........................................................58
PJ1525.........................................................58
PJ1530.........................................................58
PJ1550.........................................................58
PJ1920.........................................................59
PJ1925.........................................................59
PJ1930.........................................................59
PJ694...........................................................59
PJ696...........................................................59
PJ712...........................................................58
PJ716...........................................................58
PJ718...........................................................63
PJ722.....................................................58, 63
PJ729B.........................................................57
PJ729R.........................................................57
PJ743.....................................................57, 63
PJ744.....................................................57, 63
PJ745...........................................................57
PJ746.....................................................57, 63
PJ748...........................................................57
PJ748R.........................................................63
PJ749.....................................................57, 63
PJ762...........................................................58
PJ766...........................................................58
PJ768...........................................................63
PJ772.....................................................58, 63
PJ800...........................................................57
PJ801...........................................................57
PJ802...........................................................57
PJ806...........................................................57
PJ925R...................................................57, 63
PJ925W.......................................................57
www.adc.com
+1-952-938-8080
PJ926B.........................................................57
PJ926R.........................................................57
PJ926W.......................................................57
PJ946.....................................................59, 63
PJ948...........................................................63
PJ952...........................................................59
PLG-100050................................................57
PLG-100051................................................57
PLG-100052................................................57
PWBP-1723...........................................22, 31
PWBP-2023...........................................22, 31
PWBP-3523...........................................22, 31
PWBP-4023...........................................22, 31
PWBP-5223...........................................22, 31
PWBP-6023...........................................22, 31
PWBP-7023...........................................22, 31
PWBP-8023...........................................22, 31
PWBP-8023BT..............................................48
R
RAC-7B0162................................................21
RAC-7C0353...............................................30
RAC-7C0539...............................................21
RAC-7C0545...............................................21
RAC-7C0551...............................................21
RAC-7C0554...............................................30
RAC-7C0633...............................................21
RAC-7C0639...............................................21
RAC-7C0645...............................................21
RAC-7C0810...............................................21
RAC-7C0811...............................................21
RINST-DSX7-PW.....................................22, 31
RINST-DSXRFL-PW............................22, 31, 34
RINST-FLR.....................................................34
RWS19........................................................52
RWS23........................................................52
RWS23-BLK.................................................52
RWS23-PUT.................................................52
S
SHD-HR-44N................................................34
SHD-HR-85..................................................34
SHD-HR-91..................................................34
T
T1544-00E...................................................50
T1544-11B...................................................50
U
UEGP-7PW...................................................30
1-800-366-3891
69
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 For a listing of ADCs global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
103253AE 6/07 Revision 2007 ADC Telecommunications, Inc. All Rights Reserved