You are on page 1of 1

CMP

CABLE GLAND AND CABLE CONNECTION SPECIALISTS

CMP HAZARDOUS AREA PRODUCTS

PX2K CABLE GLAND

PX2K Flameproof Ex d, Increased Safety Ex e, Restricted Breathing Ex nR Compound Barrier Cable Gland
CMP Type PX2K Triple Certified Flameproof (Type d), Increased Safety (Type e) and Restricted Breathing (Type nR) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of armoured cable providing a compound barrier seal around the cable conductors and an environmental seal on the cable outer sheath. The cable gland provides mechanical cable retention and electrical continuity via armour termination. A combined detachable armour cone and compound tube, together with AnyWay universal clamping ring arrangement allows the cable to be easily disconnected from the equipment, for maintenance and change out etc., and re-connected with the same consummate ease. This feature also facilitates remote make off procedures when the termination is to be conducted in confined spaces or in areas of restricted access. The CMP PX2K cable gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14. The PX2K is supplied in kit form inclusive of two detachable armour cones. Stepped Cone is suitable for SWA cables, Grooved Cone is suitable for all other approved armoured cables.
C

TECHNICAL DATA
Type Design Specification ATEX Cetification Code of Protection Category PX2K BS 6121:Part 1:1989, EN 50262:1999 SIRA06ATEX1097X II 2 GD Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66 - Equipment ATEX Zone 1, Zone 2, Zone 21, & Zone 22 - Gas Groups IIA, IIB, IIC EN 60079-0:2004, EN 60079-1:2004, EN 60079-7:2003, EN 60079-15:2003, EN 61241-0:2004, EN 61241-1:2004 IECEx SIR 06.0044X Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66 IEC 60079-0:2004, IEC 60079-1:2003, IEC 60079-7:2001, IEC 60079-15:2005, IEC 61241-0:2004, IEC 61241-1:2004 POCC GB. 05.B01912 Ex d IIC U, Ex e II U OCT P 52350.0-2005, OCT P 52350.1-2005, OCT P 52350.7-2005 PPC 00-18262 KZ7500052.05.01.00063 08-067693 01/00172 E-6157 01-LD 234401-PDA -60C to +100C IP66, IP67, IP68 5046 C549G DTS01 : 91 5046 C549G-D Brass, Electroless Nickelplated Brass, Stainless Steel, Aluminium CMP SOLO LSF Thermoplastic Elastomer / Epoxy Resin Barrier Compound Wire Braid Armour, Single Wire Armour (SWA), Screened Flexible Wire Braid (e.g. CY / SY), Steel Tape Armour (STA) Pliable Wire Armour (PWA) Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring Unique CMP "LRS" Outer Seal (Load Retention Seal) Inner Compound Barrier & Cable Outer Sheath Locknut, Shroud, Entry Thread Seal, Serrated Washer, Earth Tag, Adaptor/Reducer
L L
E A

TEL 0044 191 490 1547 FAX 0044 477 5371 TEL 0044 117 977 4647 FAX 0044 977 5582 WWW.THORNEANDDERRICK.CO.UK

Compliance Standards IECEx Approval Number Code of Protection Category Compliance Standards GOST R Certificate Number Code of Protection Category Compliance Standards GGTN Permit Number GOST K Certificate Number RoK Permit for Use Number Lloyds Approval Number DNV Approval Number ABS Approval Number Continuous Operating Temperature Ingress Protection Rating Ingress Protection Document Deluge Protection Compliance Deluge Protection Document Cable Gland Material Seal Material Cable Type Armour Clamping Sealing Technique Sealing Area(s) Optional Accessories

THORNE & DERRICK UK

WWW.CABLEJOINTS.CO.UK

Note: Dedicated version for Steel Wire Armour type is PX2KW. Dedicated version for all other Armour types is PX2KX Note: This standard design concept is also available with bi-code approvals, suitable for installation in systems complying with NEC wiring code rules.

Cable Gland Selection Table


Available Entry Threads C Cable Gland Size 20S/16 20S 20 25S 25 32 40 50S 50 63S 63 75S 75 90 Standard Metric M20 M20 M20 M25 M25 M32 M40 M50 M50 M63 M63 M75 M75 M90 NPT 1/2 1/2 1/2 3/4 3/4 1 1-1/4 1-1/2 2 2 2-1/2 2-1/2 3 3 Option NPT 3/4 3/4 3/4 1 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 3 3-1/2 3-1/2

Armour Range Diameter Number Overall Ordering Cable Across Across Nominal Over Cable PVC Minimum of Gland Flats Corners Protrusion Reference Conductors Diameter Grooved Stepped Thread Shroud Cores D Cone Cone Weight Length (Brass Metric) A B D Length E Reference* (Kgs) F # Max Max Min Max Min Max Min Max Max Max 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 12.6 12.6 12.6 17.5 17.5 23.6 30.0 36.6 41.0 47.9 53.7 59.8 64.3 75.3 15 15 15 29 29 51 80 122 149 205 259 320 364 500 6.1 9.5 12.5 14.0 18.2 23.7 27.9 35.2 40.4 45.6 54.6 59.0 66.7 76.2 11.5 15.9 20.9 22.0 26.2 33.9 40.4 46.7 53.1 59.4 65.9 72.1 78.5 90.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.9 1.25 24.0 1.0 0.9 1.25 24.0 1.0 0.9 1.25 30.5 1.0 1.25 1.6 37.5 1.0 1.25 1.6 37.5 1.0 1.6 2.0 46.0 1.0 1.6 2.0 55.0 1.0 2.0 2.5 60.0 1.0 2.0 2.5 70.0 1.0 2.0 2.5 75.0 1.0 2.0 2.5 80.0 1.0 2.0 2.5 89.0 1.0 2.0 2.5 99.0 1.6 3.15 3.15 114.0 26.6 26.6 33.3 40.5 40.5 51.0 61.0 66.5 78.6 83.2 89.0 101.6 111.1 128.6 58.5 58.5 60.5 67.5 67.5 69.5 78.0 75.5 80.5 91.5 92.0 99.0 102.0 120.0
20S16PX2K1RA

All dimensions in millimetres


Note: *LSF Shrouds also available on request. Alternative armour clamping range available for non-standard armour sizes. Marine approvals including Lloyds, DNV & ABS are also available from CMP Products. # Other thread forms are available

131

www.cmp-products.com

LL

LL

B D

05

20SPX2K1RA 20PX2K1RA 25SPX2K1RA 25PX2K1RA 32PX2K1RA 40PX2K1RA 50SPX2K1RA 50PX2K1RA 63SPX2K1RA 63PX2K1RA 75SPX2K1RA 75PX2K1RA 90PX2K1RA

PVC04 PVC04 PVC06 PVC09 PVC09 PVC11 PVC15 PVC18 PVC21 PVC23 PVC25 PVC28 PVC30 PVC32

0.200 0.200 0.230 0.330 0.330 0.510 0.720 0.825 0.860 1.450 1.600 2.300 3.050 5.000