PRDS Valve

Pressure reduction and desuperheating in a single valve Efficient mixing of steam with spray water Compact High turndown ratios upto 40:1 Ease of maintenance Designed to suit almost all your applications for accurate pressure and temperature control Different Options for use Standard Arca PRDS valve with single stage pressure reduction for normal duty conditions. Special Arca PRDS valve for high pressure drops with a multi-step trim Pressure balanced trims to achieve less thrust requirements for actuator even at very high differential pressures Perforated plugs and p silencer cages to keep the noise level within acceptable limits Angle valve design on request Working Principle In the Arca combined PRDS valve, spray water is injected at the Vena contracted region immediately after the pressure reduction. This is a highly turbulent zone and since steam is at an adiabatically cooled condition, the spray water evaporates spontaneously thus effectively desuperheating the steam. Reduction of noise level due to mist formation by water is an added advantage. This is the most effective way of desuperheating since steam temperature, after pressure reduction, is not allowed to recover back.

Sr No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Description VALVE BODY TOP FLANGE(STD.) BOTTOM FLANGE SEAT PLUG BALL SPINDLE SPRING DOWEL PIN BOTTOM RING GLAND PACKING RINGS GLAND FOLLOWER GLAND NUT SLOTTED NUT GASKET (TOP & BOTTOM) GUIDE BUSH BOLTS NUTS GLAND PACKING RINGS SLEEVE COOLING WATER FLANGE GASKET COOLING WATER FLANGE BOLTS NUTS

Technical Specifications
Size Body Material 25 NB to 250 NB A216WCB, A217WC6, A351GrCF8M Others on request Rating, ANSI class #150, #300, #600, Higher on request Trim Material SS410 / SS316 Nitriding / Stelliting option also available, others on request Trim Form Parabolic, perforated, multi stage Standard Characteristics Linear, Equal %, Modified characteristics on request End Connections Flanged to ANSI B 16.5. / Butt weld to ANSIB16.25 Bonnet Standard, Extended (with Cooling Fins), Water cooled Packing Material Graphite Range ability 40:1, Higher on request

Requirements for Efficient Working of PRDS Valves Minimum downstream straight length recommended = 4 mts. Location of temperature sensor from the PRDS valve = 11m Location of pressure sensor from PRDS Valve = 1.5m A strainer at upstream of PRDS valve & Water Control Valve is a must. Spray water shall be of boiler feed water quality. Air shall be of instrument air quality. Minimum controllable temperature shall be saturation temperature +7C. Minimum pipeline velocity of 3 to 3.5 mts/sec desired.

CLICK FOR ADDRESS

You might also like