CONDUCTIVITY LIQUID LEVEL SWITCH ELECTRONICS

Intrinsically Safe Relay Versions Available


The LVC700 Series conductivity switch electronics are intended for use with OMEGA LVC-E Series electrodes and LVC-S, LVC-N, and LVC-F Series mounting assemblies. They are available in three basic series. The LVC750 series models feature a 0.3 amp solid-state switched output with the following hazardous area classifications: FM-approved intrinsically safe for Class I, Division 1, Groups A, B, C, D and Class II, Division 1, Groups E, F, and G. The LVC750 series relays can also be used with other nonpowered, strictly mechanical relay closures to provide intrinsic safety in hazardous areas. The LVC710 features a 1 amp electromechanical switched output for non-hazardous locations, bracket mounted with the bracket maintained at ground potential. The protective cover (supplied) must be in place over the screw terminal connections after wiring has been completed. The LVC710 and LVC750 are sealed in a blue polysulfone case.

Model LVC-751

125

LVC751

SPECIFICATIONS
Input and Switched Voltage: 108 to 132 Vac, 50/60 Hz Ambient Temp. Range: LVC710 and LVC750: -40 to 49C (-40 to 120F) OFF Max. Current Leakage (mA): LVC710 and LVC750: 5; LVC720: 3 Sensing Circuit, Low Level Open Circuit Max. (VAC, RMS): LVC710 and LVC750: 28 Turn-Off Time, Max.: LVC750: 12 input frequency of 50/60 Hz ac power input; LVC710: 0.5 sec; LVC720: 0.2 sec Output Switching Time, Off to On (milliseconds, approx.): LVC710: 15; LVC750: Dimensions (H x L x W): LVC710 and LVC750: 2.25 x 3 x 3.125" (57 x 76 x 79 mm); LVC720: 1.5 x 4 x 2.875" (37 x 102 x 73 mm) Weight: 1 lb (.45 kg) for LVC710 and LVC750
Note: Always treat hazardous areas with respect. Intrinsically safe relays must be installed by experienced personnel familiar with intrinsic safety wiring, and installation must be in accordance with the National Electrical Code (NEC). The relay must be mounted in a non-hazardous location, intrinsically safe wiring must be separated from non-intrinsically safe wiring, and the capacitance and inductance limitations of your copper wire run must not exceed the specifications listed in the current installation manual. Consult your local electrical code inspector for further details.

MOST POPULAR MODELS HIGHLIGHTED!

To Order (Specify Model Number)


Model Number LVC711 LVC712 LVC751 LVC752 Price $120 120 125 125 Output Current (Amps, RMS) 1 0.3 Output Circuit NO NC NO NC Function Pump-Down Pump-Up Pump-Down Pump-Up Max. Media Resistance () 50 K 50 K 50 K 50 K

Comes with complete operators manual. *Non-latching. Pump-up/pump-down units can be used for high or low latching alarm when used with an external reset switch.

K-51

One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) |

info@omega.com

www.omega.com
UNITED KINGDOM www. omega.co.uk Manchester, England 0800-488-488 UNITED STATES www.omega.com 1-800-TC-OMEGA Stamford, CT. CANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA GERMANY www.omega.de Deckenpfronn, Germany 0800-8266342 FRANCE www.omega.fr Guyancourt, France 088-466-342 CZECH REPUBLIC www.omegaeng.cz Karvin, Czech Republic 596-311-899 BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44

More than 100,000 Products Available!


Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire

Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers

Pressure, Strain and Force


Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves

Flow and Level


Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters

Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters

pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation