- Download the PSSE university version: http://www.energy.siemens.com/hq/en/services/power-transmission-distribution/power-techno logies-international/software-solutions/pss-e.htm#content=PSS%C2%AEE%20University - IEEE data download: Down load from http://www.ee.washington.

edu/research/pstca/ - Convert IEEE standard data into .raw


IEEE pss/e32I pss/e Utilities data converter, IEEE PF CONVERT DATA raw CONVERT RAW 32 -unsolved Data format Slider Binary file (*.sld) classification Save Case file (*.sav) be? .sav and .sld cannot If we build a case or a single diagram to present a power system, which format is gonna single line diagram can be open by using notepad, it shows data after Power flow raw data file (*.raw)

.raw file can be converted into a single line diagram by means of function auto draw The different between . sav file and .raw file
raw sav raw sav raw HVDC i=s] cwh0223 2012-3-8 14:49 PSS/E raw PSS/E PSS/E *.dat,*.raw *.sav *.dat *.raw*.raw *.sav

Converting load characteristics It is observed that the load characteristic is only converted from constant MVA load to constant current load and constant admittance load. The opposite is not supportive. The diagram tool including disconnect/connect busbar is not found. P103, how the sequence information is stored into the file .seq?
sequence data

But how to get this data

I didnt find the dynamic simulation interface .P120 Feeder transformer

The dynamic spreadsheet includes three models, they are device models, protection models, and other models, together with one dynamic data

The dynamic analysis can be performed at any time ,unlike previous version of pSs/e ,where it is necessary to switch back and forth between the dynamics and power flow modes using LOFL and RTRN CON, ICON and STATE initial value ???? For more information, see Program application guide

What is the conec models and conet models? Pp945 PSS/E32 PSSPLT PLT PSS/E

pdf

How to assign the zone\area \owner name.

Z base = Vbase^2/Sbase = 69*69/100=47.61 R = 1/47.61 = 0.02 X = 10/47.61 = 0.21 B = 0.002/(1/47.61) = 0.095 Power factor = true power[W]/apparent power[VA], Inductive reactance produces
a lagging power factor, Capacitive reactance produces a leading power factor.

40MVA @ 0.85 lagging Fill in the Transformer Change the character of the .txt file

P = 0.85*40MVA = 34MW

Q = 21.07MVar

---- TXT CMF - The file .con pay attention on the last line end otherwise, it continues constantly.

Cant open the sequence file thus dont know how to assign the sequence data in to the file and do a short-circuit analysis. Why before doing dynamic simulation,would the generators and load representation be converted? stabilizer