You are on page 1of 6

INTRO PLEASE EDIT ONLY LIGHT BLUE CELLS (BOX) NOT OTHER CELLS THANKS! ENGR. LEANDRO B.

PICZON II (leandrobpiczonii@hotmail.com) Professional Regulation Commission Number 0088397 Gandara, Samar, Philippines .............................................................................................. NOTE: Least Input Value is 0.001 Turn ON/OFF Earthquake Analysis by inputing ON or OFF

Download as .xls file RELEASED 1.0 Ground Floor Design

Page 1

INTRO

Page 2

INTRO

Dedication Public License (DPL)

By downloading the spreadsheet, you confirm your agreement in this license.

I. Freeware First of all, the reasons why My Structural Analysis is free: I.a. Dedication My Structural Analysis is dedicated to the most wonderful people on earth :) Annabelle, Papa Leandro I and Mama Isabel (Deceased) My Structural Analysis is dedicated to the most wonderful place on earth :) Gandara, Samar, Philippines 6706 I.b. Binary What do you get if you buy software? Lots of ones and zeros, nothing more. If they were distributed as art, I could understand paying it. But if the main goal of their order is to earn money - by fees or ads - I don't like it! I.c. Conclusion This means that I grant you the license to use My Structural Analysis as much as you like. But if you like it, I ask two things of you: say a prayer for me (and the most wonderful girl and parents you're at it ;) ) to your god - or whatever you believe - and wish us some luck.

II. Limitations II.a. Reverse Engineering Reverse Engineering is not allowed as with nearly any software. If anyone has doubts in the honesty of the code, I will give insight to a trusted organization like a university under certain limitations (for example only one copy, for a limited time, and that has to be removed after the evaluation time has ended). II.b. Warranty I tried my very best to make the code of My Structural Analysis as stable as possible, and I give you the warranty that I placed no code to cause intentional harm to your system. However, adventuring sometimes involves cutting deep into the system sometimes, and I cannot guarantee that your system will be running the same as before. For example, tensional stress hosts may stop working.

I can also give you no warranty that My Structural Analysis will calculate any structural forms, or that it will give you no false positives. For your own verification the location of the problem is shown with every entry, and if you have any questions remaining you can visit the support forum for more information. II.c. Liability Under no circumstances can you make me liable for any damage, however caused, including, but not limited to damage you might do to your system using My Structural analysis. II.d. Use of application in whole Free use is limited to the application in whole. Usage of parts only, for example the database or the plug-ins, is not permitted. II.e. Corporate use As companies are not individual persons and would have problems fullfilling the above terms, there is a license for corporate users that can be found at safer-networking.ie.

III. Distribution Here are some basic rules about distributing My Structural Analysis.

Page 3

INTRO
III.a. Private distribution You may give away single copies of the software as long as you don't modify this license or other files of the archive. III.b. Mirroring If you want to mirror My Structural Analysis, feel free to do so as long as you don't modify the original archive. If you want to be kept up to date about major updates, you can subscribe to the mailing list. III.c. Publishing You may publish My Structural Analysis in a book or magazine (or other media) by simply sending a written request for permission, including a description of your specific needs. I request a copy of the media in which My Structural Analysis is published as compensation.

Page 4

Analysis

My Structural Analysis
Computing for LIVE LOAD Weight of Person + Environment Gravity Constant Weight in Newtons Number of Person/s per Square Meter Slab Self Weight Thickness CHB per SQ.M. Total Actual Load LL + Slab 84.00 9.81 824.04 0.82 6.00 50.00 2.77 10.00 0.10 9.31 kgs m/sec2 Newton (N) KiloNewton (KN) person/s millimeter 2 KN/m kgs KN/m2 2 KN/m

Earthquake

NSCP 2.2.5.2.1 (1992)

Design Base Shear Seismic Zone Factor Importance Factor Numerical Coeff Numerical Coeff

Status : (ON;OFF) (ZIC/Rw)W V=

V= Z= I= Rw= C= S= hn= Ct=

ON 64.426 0.40 1.00 10.00 582.50 2.00 0.00 0.05 0.00 2.77

KN

C= 1.25(S)/T Site Coeff Fundamental Period of Vibration Height Ct(hn)

(2/3)

mts

T= Applied Weight

3/4

T= W=

KN

Page 1

ROAD
REINFORCED CONCRETE SLAB DESIGN SLAB 1 Edge 1 C = Continuous Ls 1000.01 mm Edge 4 Edge 2 D = Discontinuous EDGE CONDITIONS Edge 1 Edge 2 Edge 3 Edge 4 Edge 3 SHORT SPAN LENGTH OF SLAB SPAN Steel Yield Strength Concrete Compressive Strength Concrete Cover ASSUMED SLAB THICKNESS Minimum Thickness Maximum Thickness Concrete Density LOADS Selfweight Dead Load Live Load Actual Load SHORT SPAN s Actual Moment kN-m BAR SIZE mm assumed spacing along mm layer 1 or 2 effective depth mm Act. Steel Ratio Minimum Steel Ratio 0.006 0.23 20 999.999 B1 20.00 0.0157 0.0056 0.0428 0.0321 0.0157 1.27 SAFE DUCTILE 343 LONG SPAN 0.028 0.99 20 999.999 kN/m2 kN/m kN/m
2 2

D C C C LONG SPAN 2000

Ll 2000 mm

mm 2 WAY MPA MPA mm mm OK OK mm mm kN/m3

1000.01 0.50 250 21 20 50.0 33.3 54.6 26.0218 2.77 0.10 6.54 36.12

kN/m2

per M length

DESIGNED PORTION DESIGNED PORTION

B2 0.00 #DIV/0! 0.0056 0.0428 0.0321 #DIV/0! 1.27 SAFE #DIV/0! 343

bal
Max. Steel Ratio Adapted Steel Ratio Resulting Moment kN-m Remarks Concrete Condition development length mm

Page 1

You might also like