You are on page 1of 16

BNPE

IT T
Goulds Pumps
G&L Series NPE
316L SS NPE Series End Suction Centrifugal Pumps Bombas Centrfugas de Succin Final Serie NPE

Commercial Water

Goulds Pumps is a brand of ITT Corporation. Goulds Pumps es una marca de fbrica de ITT Corporation. www.goulds.com

Engineered for life

A Full Range of Product Features Una Gama Total de Caractersticas del Producto
Superior Materials of Construction: Complete AISI 316L stainless steel liquid handling components and mounting bracket for corrosion resistance, quality appearance, and improved strength and ductility. High Efficiency Impeller: Enclosed impeller with unique floating seal ring design maintains maximum efficiencies over the life of the pump without adjustment. Casing and Adapter Features: Stainless steel construction with NPT threaded, centerline connections, easily accessible vent, prime and drain connections with stainless steel plugs. Optional seal face vent/flush available. Mechanical Seal: Standard John Crane Type 21 with carbon versus silicon-carbide faces, Viton elastomers, and 316 stainless metal parts. Optional high temperature and chemical duty seals available. Motors: NEMA standard open drip-proof, totally enclosed fan cooled or explosion proof enclosures. Rugged ball bearing design for continuous duty under all operating conditions. Materiales Superiores de Construccin: Componentes completos para manejo de lquidos en acero inoxidable AISI 316L y consola para el montaje para resistencia a la corrosin, apariencia de calidad, y fuerza y ductilidad mejoradas. Impulsor de Eficiencia Superior: El impulsor encerrado con un diseo nico de anillo del sello flotante, mantiene sin ajustes, la eficiencia mxima sobre la vida de la bomba. Caractersticas de la Carcasa y del Adaptador: Construccin en acero inoxidable con NPT roscado, conexiones centrales, vlvulas de fcil acceso, conexiones de cebado y drenaje con enchufes de acero inoxidable. Cara del sello vlvula/chorro opcional disponible. Sello Mecnico: Estndar John Crane Tipo 21 con carbn en contraste con caras de silicn-carbide, elastmeros de Viton, y partes metlicas de acero inoxidable 316. Sellos de alta temperatura y productos qumicos estn disponibles. Motores: Estndar NEMA a prueba de goteo, ventilador totalmente encerrado o recintos a prueba de explosin. Diseo robusto de balineras de bolas para trabajo continuo en todas las condiciones de funcionamiento.

NPE Product Line Numbering System Lnea de Producto NPE Sistema de Numeracin
Example Product Code, Ejemplo Cdigo del Producto
1 ST 2 C 1 A 4 F Seal Vent/Flush Option, Opcin de Sello Vlvula/ChorroSeal Ven Mechanical Seal and O-ring 4 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below. Sello Mecnico y Anillo O 4 = Estndar aprobado Para sello mecnico opcional modificar el nmero de orden del catlogo con el cdigo del sello anotado abajo.
John Crane Type 21 Mechanical Seal (58 seal), Sello Mecnico John Crane Tipo 21 (sello de 58) Seal Code, Cdigo del Sello 2 4 5 6 Rotary, Stationary, Elastomers, Rotativo Estacionario Elastmeros EPR Viton EPR Viton Metal Parts, Partes Metlicas Part No., Pieza Nmero 10K18 10K55 10K81 10K62

Carbon Silicon Carbide

Silicon Carbide

316 SS

Impeller Option . . . No Adder Required For optional impeller diameters modify catalog order no. with impeller code listed. Select optional impeller diameter from pump performance curve. Cdigo del Impulsor Opcional Para impulsores con dimetros opcionales modificar el nmero de orden del catlogo con el cdigo del impulsor anotado. Escoger el impul con dimetro opcional de la curva de funcionamiento de la bomba.
Impeller Code, Cdigo del Impulsor K G H A B C D E F Pump Size, Tamao de la Bomba 1 x 1 6 1 x 1 6 1 x 2 6 Diameter Diameter Diameter 618 51516 538 5 5 618 5 4 5 5116 458 5316 478 438 4 458 4116 4716 4 358 4116 378

The various versions of the NPE are identified by a product code number on the pump label. This number is also the catalog number for the pump. The meaning of each digit in the product code number is shown at left.

Las diferentes versiones de la NPE se identifican con un nmero de cdigo del producto en la etiqueta de la bomba. Este nmero es tambin el nmero del catlogo para la bomba. El significado de cada dgito en el nmero de cdigo del producto se muestra a la izquierda.

Driver, Conductor 1 = 1 PH, ODP 7 = 3 PH, XP 2 = 3 PH, ODP 8 = 575 V, XP For frame 3 = 575 V, ODP 9 = 3 PH, TEFC mounted 4 = 1 PH, TEFC Premium Eff. version, 5 = 3 PH, TEFC 0 = 1 PH, XP substitute the 6 = 575 V, TEFC letters FRM in HP Rating, HP Potencia these positions. C = HP E = 1 HP G = 2 HP J = 5 HP Para la versin D = HP F = 1 HP H = 3 HP con el armazn Driver: Hertz/Pole/RPM, montado, Conductor: Hercios/Polo/RPM sustituya las 1 = 60 Hz, 2 pole, 3500 RPM letras FRM 2 = 60 Hz, 4 pole, 1750 RPM en estas 3 = 60 Hz, 6 pole, 1150 RPM posiciones. 4 = 50 Hz, 2 pole, 2900 RPM 5 = 50 Hz, 4 pole, 1450 RPM Material ST = Stainless steel, Acero inoxidable Pump Size, Tamao de la Bomba 1 = 1 x 1 6 2 = 1 x 1 6 3 = 1 x 2 6

GOULDS PUMPS
Commercial Water

Performance Coverage (60 Hz) Alcance de Funcionamiento (60 Hz)


METERS METROS FEET PIES

50

160 140

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

40 120 30 100 80 20 60 40

1" x 114" 6 1 2 3 HP 3500 RPM

1ST

1 1 4 " x 1 1 2 " 6 3 4 5 HP 3500 RPM

2ST

112" x 2" 6 1 5 HP 3500 RPM

3ST

10

1ST 20 1750 RPM


0

2ST 1750 RPM


20 5 40 10 60 15 80 20

3ST 1750 RPM


100 25 120 30 140 35 160 U.S. GPM m3/hr

0 0

CAPACITY (CAPACIDAD) Q

NoTES: Not recommended for operation beyond printed H-Q curve. For critical application conditions consult factory. Not all combinations of motor, impeller and seal options are available for every pump model. Please check with G&L on noncataloged numbers. All standard 3500 RPM ODP and TEFC motors supplied by Goulds Pumps, have minimum of 1.15 service factor. Standard catalog units may utilize available service factor. Any motors supplied other than Goulds Pumps check available service factor.

NOTAS: No se recomienda para funcionamiento superior al impreso en la curva H-Q. Para condiciones de aplicaciones crticas consultar con la fbrica. No todas las combinaciones de las opciones de motor, impulsor y sello estn disponibles para cada modelo de bombas. Por favor verifique con G&L en los nmeros no catalogados. Todos los motores estndar de 3500 RPM, ODP (abiertos resguardados) y TEFC (totalmente encerrados con enfriamiento forzado) provistos por Goulds Pumps tienen un factor mnimo de servicio de 1,15. Las unidades estndar de catlogo pueden utilizar el factor de servicio disponible. Verificar el factor de servicio disponible de todo motor no provisto por Goulds Pumps.

GOULDS PUMPS
Commercial Water
3

NPE Close Coupled Pump Major Components: Materials of Construction Bomba Cerrada Acoplada NPE Componentes Principales: Materiales de Construccin
100 101 347 370 513 184 108 383 123

184A

108A
349

412B

408

371

1, 2 and 3 HP 1, 2 y 3 HP

Seal Face Vent/Flush Option, Opcin Cara del Sello Vlvula/Chorro

Item No., Description, Parte No. Descripcin 100 101 108 108A 123 184 184 A 347 349 370 371 383 408 412B 513 Motor Motor Casing; Carcasa Impeller; Impulsor Motor adapter; Adaptador del motor Motor adapter seal vent/flush; Sello vlvula/chorro del adaptador del motor Deflector; Deflector Seal housing; Alojamiento del sello Seal housing seal vent/flush; Sello vlvula/chorro del alojamiento del sello Guidevane; Difusor Seal ring, guidevane; Anillo del sello, difusor Socket head screws, casing; Encajes cabezas de tornillos, carcasa Bolts, motor; Tornillos, motor Mechanical seal; Sello mecnico Drain and vent plug, casing; Enchufes de drenaje y vlvula, carcasa O-ring, drain and vent plug; Anillo O, enchufe de drenaje y vlvula O-ring, casing; Anillo O, carcasa NEMA standard, 56J flange; NEMA estndar, brida 56J

Materials, Materiales

AISI 316L SS; AISI 316L Acero inoxidable BUNA-N AISI 316L SS; AISI 316L Acero inoxidable Viton AISI 410 SS; AISI 410 Acero inoxidable Plated steel; Acero chapeado **see chart, ver tabla AISI 316L SS; AISI 316L Acero inoxidable Viton (Standard, estndar) EPR (Optional, Opcional)

, and 1 HP , y 1 HP

Footed motor for 5 HP ODP and TEFC, all explosion proof motors, see page 13. Motor con pie para 5 HP ODP y TEFC, a prueba de explosiones motores, en la pgina 13.

GOULDS PUMPS
Commercial Water

NPE Frame Mounted Pump Major Components: Materials of Construction Bomba NPE de Armazn Montado Componentes Principales: Materiales de Construccin
347 100 101 361 349 109 139 383 370 513 184 108 168 122 112 370C
184A

108A

304

412B

408

Seal Face Vent/Flush Option, Opcin Cara del Sello Vlvula/Chorro


138
Item No., Description, Parte No. Descripcin 100 101 108 108A 109 112 122 138 139 168 184 184 A 228 Casing; Carcasa Impeller; Impulsor Adapter; Adaptador Motor adapter seal vent/flush; Sello vlvula/chorro del adaptador del motor Bearing cover; Cubierta de balineras Ball bearing (outboard); Balineras de bolas (exterior) Shaft; Eje Lip-seal (inboard); Sello cubierto (interior) Lip-seal (outboard); Sello cubierto (exterior) Ball bearing (inboard); Balineras de bolas (interior) Seal housing; Alojamiento del sello Seal housing seal vent/flush; Sello vlvula/chorro del alojamiento del sello Bearing frame; Armazn de balineras AISI 316L SS; AISI 316L Acero inoxidable Cast iron; Hierro fundido Steel; Acero AISI 316 SS; AISI 316 Acero inoxidable BUNA/steel; BuNA/acero BUNA/steel; BuNA/acero Steel; Acero AISI 316L SS; AISI 316L Acero inoxidable Cast iron, Hierro fundido 371 383 400 408 412B 513

371
Materials, Materiales

228
Item No., Description, Parte No. Descripcin 304 347 349 361 370 370C Impeller locknut; Contratuerca del impulsor Guidevane; Difusor Retaining ring; Anillo de retencin Socket head screws, casing; Encaje cabeza del tornillo, carcasa Hex head screw, bearing cover; Tornillo de cabeza hexagonal, cubierta de balineras Hex head screw, bearing frame; Tornillo de cabeza hexagonal, armazn de balineras Mechanical seal; Sello mecnico Shaft key; Llave del eje Drain and vent plug, casing; Enchufes de drenaje y vlvula, carcasa O-ring, drain and vent plug; Anillo O, enchufe de drenaje y vlvula O-ring, casing; Anillo O, carcasa Materials, Materiales AISI 316 SS; AISI 316 Acero inoxidable Steel; Acero AISI 410 SS; AISI 410 Acero inoxidable Plated steel; Acero chapeado Plated steel; Acero chapeado **see chart; ver tabla Steel; Acero AISI 316 SS; AISI 316 Acero inoxidable Viton (Standard, estndar) EPR (Optional, Opcional)

Seal ring, guidevane; Anillo del sello, difusor Viton

GOULDS PUMPS
Commercial Water
5

Performance Curves 60 Hz, 3500 RPM Curvas de Funcionamiento 60 Hz, 3500 RPM
Model NPE / 1ST Size (Tamao) 1 x 114-6 RPM 3500 Curve (Curva) CN0231R01
NPSH R FEET (PIES) 50
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

METERS METROS

FEET PIES

Impeller Selections for ODP & TEFC Motors Selecciones del Impulsor para Motores ODP & TEFC
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Ordering Standard Code, HP Rating, Imp. Cdigo Estndar HP Dia. de Pedido Potencia

160 140 A 618" DIA. B 534" 120 100 80 C 5316" D 434" E 4716" 60 40 45

E D C

1 1 2

4716 4 5316 5 618

5' 48 50

6'

8' 10'

40

51 52 53 51 50

12' 48 EFF %

B A

30

HP

20

2H 1H
1 2

1 12

NoTE: Although not recommended, the pump may pass a 116 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 116.

HP

10 20 0 0

H P

3 4

HP

0 0

10

20 5

30
CAPACITY (CAPACIDAD) Q

40 10

50

60 U.S. GPM
m3 hr

METERS METROS 50

FEET PIES

Model NPE / 1ST Size (Tamao) 1 x 114-6 Impeller Selections for Exp. Proof Motors Selecciones del Impulsor para Motores Exp. Proof RPM 3500 Curve (Curva) CN0231R01
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Ordering Standard Code, HP Rating, Imp. Cdigo Estndar HP Dia. de Pedido Potencia

160 140 A 618" DIA.

NPSH R FEET (PIES)

F E

1 1 2 3

5' 45 48 50

4116 spec. 4716 4 5316 5 618

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

6' 51 52

8 10' 51 12' 48 EFF % 3H P

D C B A

40 120 100 80 20

B 534" C 5316" D 434" E 4716"


60 40

53

50

30

2H
1 1
P
2

F 4 16" Spec.
1

8' 10' 12'


1 2

1H
H P
3 4

HP

NoTE: Although not recommended, the pump may pass a 116 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 116.

10 20 0 0

H P

10

20 5

30

40 10

50

60 U.S. GPM
m3 hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS
Commercial Water

Performance Curves 60 Hz, 3500 RPM Curvas de Funcionamiento 60 Hz, 3500 RPM
Model NPE / 2ST Size (Tamao) 114 x 112-6 RPM 3500 Curve (Curva) CN0235R02
NPSH R FEET (PIES) G 5 16" DIA.
15

METERS METROS

FEET PIES

Impeller Selections for ODP & TEFC Motors Selecciones del Impulsor para Motores ODP & TEFC
10'
NOTE: Not recommended for operation beyond printed HQ curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

5' 50 55

7' 58 60 62 64 66

Ordering Standard Code, HP Rating, Imp. Cdigo Estndar HP Dia. de Pedido Potencia

40

130 120

F E D

1 1 2 3 3 5 5

378 4 458 478 5116 5 5 51516

35
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

110 100 90

H 512" A 5 1 4 " B 5116" C 478" D 458" E 4 1 4 "

15' 20' 58 55 EFF %

30

C B A
5

25

80 70 60

20

H
HP

15

50 40

F 3 7 8 "
3 4

3
HP
2

HP

10

30 20 10 0 0 20 5

HP

11 2

HP

HP

NoTE: Although not recommended, the pump may pass a 316 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 316.
160 35
U.S. GPM m3 hr

40 10

60 15

80 20

100 25

120 30

140

CAPACITY (CAPACIDAD) Q

METERS METROS

FEET PIES

Model NPE / 2ST Size (Tamao) 114 x 112-6 Impeller Selections for Exp. Proof Motors RPM 3500 Curve (Curva) CN0235R01 Selecciones del Impulsor para Motores Exp. Proof
NPSH R FEET (PIES) 5' 50 7' 58 60 62 64 66 64 D 458" E 414" 62 60 58 55 EFF % 20' 10' 15'
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Ordering Standard Code, HP Rating, Imp. Cdigo Estndar HP Dia. de Pedido Potencia

F E D B

1 1 2 3

378 4 458 5116

110
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

55

30

100 90

B 5116" DIA.

25

80 70 6

20

15

50 40

NoTE: Although not recommended, the pump may pass a 316 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 316.

F 378"

3
3 4

10

30 20 10 0 0 20 5 40

HP

2
1 HP

HP

11 2

HP

HP

60 10 15

80 20

100 25

120 30

140

160

U.S. GPM m3 hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS
Commercial Water
7

Performance Curves 60 Hz, 3500 RPM Curvas de Funcionamiento 60 Hz, 3500 RPM
Model NPE / 3ST Size (Tamao) 112 x 2-6 RPM 3500 Curve (Curva) No. CN0239RO2
NPSH R FEET (PIES) 50 5'

METERS METROS

FEET PIES

Impeller Selections for ODP & TEFC Motors Selecciones del Impulsor para Motores ODP & TEFC
NOTE: Not recommended for operation beyond printed HQ curve. NOTA: No se recomienda para funcionamiento superior al 64 impreso en la curva H-Q.

Ordering Standard Code, HP Rating, Imp. Cdigo Estndar HP Dia. de Pedido Potencia

35

120

55

60

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

30 100

G 538" DIA. H 5"

6'

E D C B A

1 1 2 3 3 5 5

358 4116 438 458 4 5 538

7'

66

10'
5 HP

17' 66EFF % 64 60 55

25 80 20 60 15 40

A 434" B 458" C 438" D 4116" E 358"


1H P

H G

10

3H
1 1 HP
2H P

20

NOTE: Although not recommended, the pump may pass a 11 32 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 1132.

0 0

20 5

40 10

60 15

80 20

100 25

120 30

140

160 35

U.S. GPM m3 hr

CAPACITY (CAPACIDAD) Q

METERS METROS

FEET PIES

Model NPE / 3ST Size (Tamao) 11/2 x 2-6 Impeller Selections for Exp. Proof Motors RPM 3500 Curve (Curva) CN0239R01 Selecciones del Impulsor para Motores Exp. Proof
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Ordering Standard Code, HP Rating, Imp. Cdigo Estndar HP Dia. de Pedido Potencia

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

30

100

NPSH R FEET (PIES) 50 55

5'

E D

1 2 3

358 4116 458

6' 60

7' 64 66 66 64 60 55 EFF % 10'

25

80

B 4 8" DIA.
5

20

60

D 4116" E 3 8"
5

NOTE: Although not recommended, the pump may pass a 11 32 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 1132.

15 40 10 20

1H

P
1 1
2

3H
HP 2H P

0 0

20 5

40 10

60 15

80 20

100 25

120 30

140

160 35

U.S. GPM m3 hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS
Commercial Water

Performance Curves 60 Hz, 1750 RPM Curvas de Funcionamiento 60 Hz, 1750 RPM
Model NPE / 1ST Size (T amao) 1 x 114-6 RPM 1750 Curve (Curva) CN0233R00
METERS FEET METROS PIES NoTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller, Impulsor Opcional Ordering Code, Cdigo de Pedido Dia.

NPSH R FEET (PIES) 12


TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

40 35 A 618" DIA. B 534" 30 C 5316" D 434" 45

A
5' 48 50 51 52 53 51 6' 8' 10' 12' 50 48 EFF %
1 3

618 5 5316 4 4716 4116

B C D E F

10

25 20

H P

E 4716" 4 15 10 2 5 0 F 4116" 8' 9' 12'

NOTE: Although not recommended, the pump may pass a 116 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 116.

0 0 1

5 2

10 3

15 4 5

20 6

25 7

30 8

U.S. GPM m3 hr

CAPACITY (CAPACIDAD) Q

METERS METROS

FEET PIES

Model NPE / 2ST Size (T amao) 114 x 112-6 RPM 1750 60 Hz


K 6 8" DIA.
1

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller, Impulsor Opcional Ordering Code, Cdigo de Pedido Dia.

NPSHR FEET (PIES) 50 5' 55 7' 58 10' 60 62 64 66 58 55 EFF % 15' 20'

35 10
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

32.5 G 51516" 30 H 512"

K G H A B C D
1 /2 H

618 51516 5 5 5116 478 458 4 378

9 8 7 6 5 4 3 2

27.5 A 514" 25 22.5 20 17.5 15 12.5 10 7.5 5 0 0 10 2 4 20 6 30 8 B 5116" C 478" D 458" E 414"

E F

F 378"
1 /3

HP

40 10

50 12

60 14

70 16

80

U.S. GPM m3 hr

NOTE: Although not recommended, the pump may pass a 316 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 316.

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS
Commercial Water
9

Performance Curves 60 Hz, 1750 RPM Curvas de Funcionamiento 60 Hz, 1750 RPM
Model NPE / 3ST Size (Tamao) 112 x 2-6 RPM 1750 60 Hz
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

METERS METROS

FEET PIES

Optional Impeller, Impulsor Opcional Ordering Code, Cdigo de Pedido Dia.

NPSH R FEET (PIES) 30


TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

5' 50 G 5 8" DIA.


3

55

G
60 6' 64 7' 66 10'

538 5 4 458 438 4116 358

H
17' 66 64 60 55 EFF %
1

8 7 6 5

25 H 5" 20 A 434" B 458" C 438" 15 D 4116" E 358"

A B C D
/2 H

4 3 2 5 1 0 0 0 0 10

/3

HP

NOTE: Although not recommended, the pump may pass a 11 32 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 1132.

10 2 4

20 6

30 8

40 10

50 12

60 14

70 16

80 18

U.S. GPM m3 hr

CAPACITY (CAPACIDAD) Q

Performance Curves 50 Hz, 2900 RPM Curvas de Funcionamiento 50 Hz, 2900 RPM
Model NPE / 1ST Size (Tamao) 1 x 114-6 RPM 2900 50 Hz
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

METERS METROS

FEET PIES

Optional Impeller, Impulsor Opcional Ordering Code, Cdigo de Pedido Dia.

40 120
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

A
NPSH R FEET (PIES) EFF % 45 5' 48 50 51 53 52 6' 8' 10' 51 50 12' 48

618 5 5316 4 4716 4116

B C D E F
1 1/
1

30

100

A 6 8" DIA.
1

80 20

B 5 4 "
3

C 5316" 60 D 43 4 " E 4716" 40 10 20 F 4116" 8' 9' 12'

HP

HP

NOTE: Although not recommended, the pump may pass a 116 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 116.

/4 H P

/2 H

0 0

10

20 5

30
CAPACITY (CAPACIDAD) Q

40 10

50

U.S. GPM 60 m3 hr

GOULDS PUMPS
Commercial Water

10

Performance Curves 50 Hz, 2900 RPM Curvas de Funcionamiento 50 Hz, 2900 RPM
METERS METROS FEET PIES

Model NPE / 2ST Size (Tamao) 114 x 112-6 RPM 2900 50 Hz


K 618" DIA. 50 EFF % 5' 55 58 60 62 66 64 7' 10'

30

100 90

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller, Impulsor Opcional Ordering Code, Cdigo de Pedido Dia.

NPSH R FEET (PIES)

G 51516" H 512" A 514" B 5116" C 478" D4


58"

K
15' 58 20' 55

618 51516 5 5 5116 478 458 4 378

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

25

80 70

G H A B C
3 HP

20 60 15 50 40 10 30 20

E 4 1 4 " F 378"
11 /2
3

D E F

HP

/4

10 7

HP

HP

HP
120 25 30
U.S. GPM m3 hr

0 0

20 5

40 10

60 15

80 20

100

NOTE: Although not recommended, the pump may pass a 316 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 316.

CAPACITY (CAPACIDAD) Q

METERS METROS

FEET PIES

Model NPE / 3ST Size (Tamao) 112 x 2-6 RPM 2900 50 Hz

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Optional Impeller, Impulsor Opcional Ordering Code, Cdigo de Pedido Dia.

25 EFF % 70
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H

NPSH R FEET (PIES) G 538" DIA. H 5" A 434" B 458" C 438" 50 5' 55 60 6' 6 66 7' 10' 66 64 3 HP 60 55

G H A B C D E
2H P

538 5 4 458 438 4116 358

20 60 50 40 10 30 20 5 10 0 0

15

D 4116" E 358"

1 1
1H
3

HP

4 H

P
U.S. GPM

NOTE: Although not recommended, the pump may pass a 11 32 sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 1132.

0 0

20 5

40 10

60 15

80 20

100 25

120 30

m3 hr

CAPACITY (CAPACIDAD) Q

GOULDS PUMPS
Commercial Water
11

NPE Close Coupled Dimensions, Weights and Specifications NPE Acople Cerrado Dimensiones, Pesos y Especificaciones
Clockwise Rotation Viewed from Drive End Rotacin en Direccin de las Agujas del Reloj Visto desde el Extremo del Motor
DISCHARGE DESCARGA FILL AND VENT CARGA Y VLVULA 414 Y W C MAX.
1 PHASE UNITS ONLY UNIDADES MONOFSICAS SOLAMENTE

2 34

SUCTION SUCCIN

6 516 MAX.
30 TYP.

414

311/16 MAX. (4) 1332 DIA. MOUNTING HOLES (4) 1332 DIA. AGUJEROS DE MONTAJE

DRAIN PLUG 14 ENCHUFE DE DRENAJE 14

21516 678

21516

16

5 6 12

34

oDP and TEFC , and 1 HP (standard), ODP y TEFC , y 1 HP (estndar)


DISCHARGE DESCARGA FILL AND VENT CARGA Y VALVULA 41 4 Y W C MAX. 1 PHASE ONLY MONOFSICA SOLAMENTE

234

X
SUCTION SUCCIN

612 MAX.

MOTOR CRADLE HORQUILLA DEL MOTOR DRAIN DRENAJE

30 TYP

41 4

31116 4 MAX. HOLE 4-MOUNTING HOLES DIA. 4-AGUJEROS DE MONTAJE


1332 13 32 DIA.

21516 818

21516

5 814

13132

oDP and TEFC 1, 2 and 3 HP (standard), ODP y TEFC 1, 2 y 3 HP (estndar)

Specifications Especificaciones
Capacities to: 85 GPM (322L/min) at 1750 RPM 170 GPM (643L/min) at 3500 RPM Heads to: 39 feet (12 m) at 1750 RPM 150 feet (46 m) at 3500 RPM Working pressures to: 125 PSIG (9 bars) Maximum temperatures to: 250 F (121 C) Direction of rotation: Clockwise when viewed from motor end. Motor specifications: NEMA 56J frame, 1750 RPM, HP. 3500 RPM through 5 HP. Open drip-proof, totally enclosed fan-cooled or explosion proof enclosures. Stainless steel shaft with ball bearings. Single phase: Voltage 115/230 ODP and TEFC. (3 and 5 HP model 230 V only) Built-in overload with auto-reset provided. Three phase: Voltage 208230/460 ODP, TEFC and EX PROOF. NOTE: For three phase motors, overload protection must be provided in starter unit. Starter and heaters must be ordered separately. Capacidades: 85 GPM (322L/min) a 1750 RPM 170 GPM (643L/min) a 3500 RPM Cargas: 39 pies (12 m) a 1750 RPM 150 pies (46 m) a 3500 RPM Presin de trabajo: 125 PSIG (9 baras) Temperatura mxima: 250 F (121 C) Direccin de rotacin: En direccin de las agujas del reloj visto desde el extremo final del motor. Motores: Armazn 56J NEMA, 1750 RPM HP 3500 RPM a 5 HP . . Cubiertas abiertas resguardadas, totalmente encerradas enfriadas por ventilador o a prueba de explosiones. Eje de acero inoxidable con balineras de bolas. Monofsicos: Voltaje 115/230 ODP y TEFC. (modelo 3 y 5 HP 230 voltios solamente) Se proporciona proteccin trmica contra sobrecarga construida con reseteo automtico. Trifsicos: Voltaje 208-230/460 ODP TEFC y EX PROOF. , NOTA: Para motores trifsicos se debe de proporcionar la proteccin trmica contra sobrecarga en la unidad de arranque. El arrancador y los calentadores se deben pedir por separado.

GOULDS PUMPS
Commercial Water

12

NPE Close Coupled with Footed Motor, Explosion-proof and 5 HP Motors NPE Acople Cerrado con Motor con Patas, Motores a Prueba de Explosin Y 5 HP
All Explosion Proof Motors and 5 HP oDP and TEFC Todos los motores son a prueba de explosiones, 5 HP, ODP (abiertos resguardados) y TEFC (totalmente encerrados con enfriamiento forzado)
DISCHARGE DESCARGA

FILL AND VENT CARGA Y VLVULA SUCTION SUCCIN 8 1/ 2 4 1/ 4 Y W

C. MAX.

X 61/2 DIA. 31/2


1/3

4 1/4

7/8

M DRAIN PLUG 1/4 ENCHUFE DE DRENAJE 1/4

3 33/4

47/8 61/2

Dimensions Determined by Pump, Dimensiones Determinadas por la Bomba


Pump, Bomba 1ST 2ST 3ST Suction, Succin 1 1 2 Discharge, Descarga 1 1 1 HP 3 5 15 W 3 516 3 3 X 438 4 4 8
5

Y 2 218 2 8
1

L 4916 5 18 5 8
1

M 7516 7 78 7 78

Available Motor Weights and Dimensions, Pesos y Dimensiones Disponibles del Motor
HP 1 1 2 3 5 Motor Weights, Pesos del Motor 1 Phase, Monofsicos 3 Phase, Trifsicos ODP 16 19 22 28 33 40 42 TEFC 21 24 26 35 39 43 EXP 47 41 49 56 60 ODP 19 21 23 27 32 41 42 TEFC 18 21 21 27 33 37 45 EXP 27 30 30 37 44 C Max. Length, (Longitud) 91516 10 11 11516 12116 12 16
7

NoTES: 1. Pump will be shipped with top vertical discharge position as standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 6mm bolts to 5 6 lbs.-ft. 2. Motor dimensions may vary with motor manufacturers. 3. Dimensions in inches, weights in pounds. 4. For explosion proof motor dimensions consult factory for information. 5. Not to be used for construction purposes unless certified.

NOTAS: 1. Las bombas se transportarn con la descarga vertical superior como estndar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posicin deseada, y reemplazar y apretar los tornillos de 6mm a 5 6 libras-pies. 2. Las dimensiones del motor puede que varen con los fabricantes. 3. Dimensiones en pulgadas, pesos en libras. 4. Para las dimensiones de los motores a prueba de explosin consultar con la fbrica para informacin. 5. No usar para propsitos de construccin sin certificar.

14

Dimensions in inches, weights in pounds. Dimensiones en pulgadas, pesos en libras.

GOULDS PUMPS
Commercial Water
13

NPE Frame Mounted Dimensions, Weights and Specifications NPE Armazn Montado Dimensiones, Pesos y Especificaciones
DISCHARGE DESCARGA FILL AND VENT CARGA Y VLVULA 41/4 Y W 2 X SUCTION SUCCIN 77/8 MAX. 311/16 4 MAX. DRAIN DRENAJE HG HE HA HE HL HF HB HD
7 /8

CP

31/2

SPACER COUPLING (ACOPLE DEL ESPACIADOR) COUPLING GUARD GUARDA ACOPLE


LOCATION FOR SINGLE PHASE ONLY UBICACIN PARA MONOFSICOS SOLAMENTE

C. MAX.

31/8 MAX.

KEYWAY 3/32 X 3/16 CHAVETERO 3/32 X 3/16

4 HOLES 38 DIA. 4 AGUJEROS 38 DIA. HP

Specifications Especificaciones
Capacities to: 85 GPM (322L/min) at 1750 RPM 170 GPM (643L/min) at 3500 RPM Heads to: 39 feet (12 m) at 1750 RPM 150 feet (47 m) at 3500 RPM Working pressures to: 125 PSIG (9 bars) Maximum temperatures to: 250F (121C) Direction of rotation: Clockwise when viewed from motor end. Motor specifications: T-frame single and three phase. Open drip-proof, TEFC or explosion proof enclosures are available for 60 Hz, 3500 and 1750 RPM operation. For three phase motors, overload protection must be provided in starter unit. Starter and heaters must be ordered separately. Capacidades: 85 GPM (322L/min) a 1750 RPM 170 GPM (643L/min) a 3500 RPM Cargas: 39 pies (12 m) a 1750 RPM 150 pies (47 m) a 3500 RPM Presin de trabajo: 125 PSIG (9 baras) Temperatura mxima: 250F (121C) Direccin de rotacin: En direccin de las agujas del reloj visto desde el extremo final del motor. Motores: Armazn T- monofsico y trifsico. A prueba de goteo, TEFC o recintos a prueba de explosin estn disponibles para funcionamiento de 60 Hz, 3500 y 1750 RPM. Para motores trifsicos se debe de proporcionar la proteccin trmica contra sobrecarga en la unidad de arranque. El arrancador y los calentadores se deben pedir por separado.

NPE-F

FILL AND VENT CARGA Y VLVULA

4 1 4

DISCHARGE DESCARGA

CP MAX. Y W

SUCTION X SUCCIN

2
7 /8

KEYWAY 332 x 316 CHAVETERO 332 x 316

412 DRAIN DRENAJE 2 5 1 4 2

31116 MAX. 4 L

12

4 HOLES 38 DIA. 4 AGUJEROS 38 DIA.

314 41316

916

GOULDS PUMPS
Commercial Water

14

Dimensions and Weights Dimensiones y Pesos


Dimensions and Weights Determined by Pump, Dimensiones y Pesos Determinados por la Bomba
Dim. HL Determined by Pump and Motor, Dim. HL Determinadas por la Bomba y el Motor X 438 4 12 4 58 Y 2 2 1/8 Wt., Peso 22 12 23 Frame, Armazn 56 140 4 916 518 180 6716 7

Pump, Bomba 1ST 2ST 3ST

Suct. NPT, Disch. NPT, Succin Descarga NPT NPT 1 14 1 1 12 2 114 112

CP 121516 13 12

L 6 716 7

W 35/16 3 34

Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundacin y del Motor
Motor Frame, Armazn HA del Motor 56 143T 145T 182T 184T 8 10 HB HD HE HF HG HP Wt. Max., Peso Mx 30 43 Shims, Deflector 1 Horsepower, Fuerza Frame Size, Tamao del Armazn 56 26 7 14 3 34 24 234
7 1

3500 RPM Single Phase, Monofsicos ODP 2 1 2


1 1

Three Phase, Trifsicos ODP


1

C Max.

Wt. Max., Peso Mx. 45 45 52 63 112

26

6 78

3 18 22 38 238

1 8

TEFC 2 1 2
1

TEFC
1

2 1 112

2 1 112

13 13 38 14 14 16 58 18 8
1

143T 145T 182T 184T

2 3 5

2 3 5

NOTES: 1. Pump will be shipped with top vertical discharge position as standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 6mm bolts to 5 6 lbs.-ft. 2. Motor dimensions may vary with motor manufacturers. 3. Dimensions in inches, weights in pounds. 4. For explosion proof motor dimensions consult factory for information. 5. Not to be used for construction purposes unless certified.

NOTAS: 1. Las bombas se transportarn con la descarga vertical superior como estndar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posicin deseada, y reemplazar y apretar los tornillos de 6mm a 5 6 libras-pies. 2. Las dimensiones del motor puede que varen con los fabricantes. 3. Dimensiones en pulgadas, pesos en libras. 4. Para las dimensiones de los motores a prueba de explosin consultar con la fbrica para informacin. 5. No usar para propsitos de construccin sin certificar.

1 12 3 5

112 2 3 5

GOULDS PUMPS
Commercial Water
15

IT T
Typical Applications, Aplicaciones Tpicas
Specifically designed for a broad range of general applications traditionally requiring various materials such as all iron, bronze fitted or all bronze construction. Water circulation Booster service Liquid transfer Spray system Chillers Washing/cleaning systems Injection molding cooling Reverse osmosis Air scrubbers Heat exchangers Filtration systems Jockey pumps OEM applications General water services Diseadas especficamente para una amplia variedad de aplicaciones generales, requiriendo tradicionalmente varios materiales, tales como hierro, bronce empotrado o todas las construcciones de bronce. Circulacin de agua Aumento de presin Transferencia de lquidos Sistemas de aspersin Enfriadores Sistemas de lavado/limpieza Enfriamiento con molde por inyeccin Osmosis reversa Depuradores de aire Termopermutadores Sistemas de filtracin Bombas auxiliares Aplicaciones OEM Servicios generales de agua Car Wash, Lavadero de Autos Pure Water/ OEM, Agua Pura/ OEM

Commercial Water

Brewery, Fbrica de Cerveza

Pressure Booster System, Sistema de Aumento de Presin

Chiller, Enfriador

Goulds Pumps, G&L and the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Corporation.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Goulds Pumps, G&L y el smbolo ITT Engineered Blocks son marcas registradas y marcas comerciales de ITT Corporation.
LAS ESPECIFICACIONES ESTN SuJETAS A CAMBIO SIN PREVIO AVISO.

BNPE June, 2008 2008 ITT Corporation

Junio, 2008

Engineered for life

You might also like