You are on page 1of 8

Planning Manual Esprit 770 Dynamic Power

Ergoline has opened a new era in UV performance with its fu-


ture-oriented Dynamic Power technology.
Adjustable electronic ballasts give around 25% extra UV output
on each watt of energy input. By investing in technology, we
help you secure the future of your business.
Computer-calculated Power Settings give our sunbeds real
versatility – for example, you can operate our Dynamic Power
to save energy or operate at full tanning performance to match
whichever way you prefer to run your salon – no lamp changes,
no adaptations to your sunbeds. Simply set the configuration
and it’s done. Good to know: Energy-saving mode extends the
lamp’s life to up to 1,200 hours. The Power Setting chosen en-

Esprit 770
sures even lamp control up to the maximum power level select-
ed throughout each lamp’s lifespan. Each Dynamic Power
model is available with an IQ-Sensor technology for an individ-
ual tan from head to toe.

Contents

Device description . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maximum exhaust pipe lengths. . . . . . . . . . . . . . . . . 5
Device cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Surround cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Exhaust air accessories. . . . . . . . . . . . . . . . . . . . . . . 7
Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . 8
Sound system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AQUA FRESH AROMA system . . . . . . . . . . . . . . . . . 8
IR interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
IQ sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Esprit 770 Dynamic Power – 1


Esprit 770 Dynamic Power Planning Manual

Device description

1. Air nozzles facial cooling 16 17 18


2. Face tanner (UV high-pressure lamps)
3. Shoulder tanner with sound system
12 13 14 12 15
4. Headphone jack and MP3 connection
5. Infrared interface 11
6. Acrylic glass panel, base
7. Intermediate panel
Esprit 770

8. UV low-pressure lamps, base 10 20 19


9. Air nozzles body cooling, feet end
10. UV low-pressure lamps, side part
2
11. UV low-pressure lamps, canopy
1
12. Nozzles AQUA FRESH AROMA system 3
13. Air nozzles body cooling 4
14. Service handle
15. Display unit 21
16. Accent lighting internal
17. Central exhaust air bracket (optional)
18. Accent lighting canopy 5
19. Signature lighting
20. Accent lighting front panel
21. Sensor and base station (optional) 9 8 7 6 07952 / 0

21

15660 / 0

2 – Esprit 770 Dynamic Power


Planning Manual Esprit 770 Dynamic Power

Technical data

Electrical data Noise emission


Nominal power consumption: Acoustic pressure level: 62.9 db (A)
w/o air condition 14 000 W Inlet and exhaust air
with air condition 16 900 W Temperature difference, supply/exhaust air: 14 °C
Nominal voltage: 400 – 415 V 3N~ Max. air requirement: 2900 m3/h
Nominal frequency: 50 Hz Opt. ambient temperature: 25 °C – 30 °C
Rated fusing: 3 x 35 A (time-delay)

Esprit 770
Max. ambient temperature: 15 °C – 40 °C
Mains supply line (for example): H05VV-F 5G 6 mm² Max. inlet air temperature: 40 °C
or Exhaust cross section w/o exhaust system: 588 cm2
Nominal voltage: 230 – 240 V ~3 Cabin inlet air cross section at 1.5 m/s: 5370 cm2
Nominal frequency: 50 Hz Exhaust cross section with exhaust system: 710 cm2
Rated fusing: 3 x 50 A (time-delay) Warm air return: possible
Mains supply line (for example): H05VV-F 4G 10 mm²
Performance:
Canopy:
UV low pressure lamps 22 x 80 – 200 W1)
UV high pressure lamps 3 x 520 W2)
Lower part:
UV low pressure lamps 18 x 80 – 200 W1)
Side part:
UV low pressure lamps 8 x 80 – 200 W1)
UV high pressure lamps 1 x 520 W2)
Shoulder tanner:
UV high pressure lamps 2 x 250 W
1) Electronically controlled
2) Broad-band radiators

Esprit 770 Dynamic Power – 3


Esprit 770 Dynamic Power Planning Manual

Dimensions

B 1525 mm Z

H5
B1 845 mm

H4
B2 205 mm L3
L2 L4
B+ 1545 mm
B– 1380 mm
X
L (w/o shoulder tanner) 2234 mm L1
B1
Esprit 770

L (with shoulder tanner) 2380 mm

H1
L1 2200 mm

Y
H
L
H2 L
L2 1762 mm
TK BK
L3 235 mm
B-
L4 243 mm B
B+
L5 867 mm 07677 / 1
L7 1120 mm L5
B2
H 1470 mm o
L7

H1 1965 mm
H2 1106 mm
H3 – mm
H4 450 mm
H5 56 mm
H9
H8

H6 1879 mm
H7
H6

H7 2002 mm
H8 2215 mm
H9 2360 mm
X 1245 mm 07678 / 0

Y 582 mm
Z 2236 mm
∅ 300 mm
BK 2400 mm
TK 2300 mm

4 – Esprit 770 Dynamic Power


Planning Manual Esprit 770 Dynamic Power

Maximum exhaust pipe lengths

Calculation base (without additional ventilator):


Back pressure 100 Pascal
Air pressure 100,000 Pascal
Air temperature 40 °C
Density 1.112 kg/m3
Dynamic inertia of the air 1.92E-05 Pa x s

Esprit 770
Roughness Permissible
Corrugated pipe 90° bend in line
(at centre) Flow volume Loss coefficient length of
∅ (metal)
kabsolute straight line
mm mm m³/h of pipe of bend pieces m
0 10
1 9
300 8 2550 0.1821) 0.211)
2 8
3 7
Roughness Permissible
Corrugated pipe 90° bend in line
(at centre) Flow volume Loss coefficient length of
∅ (metal)
kabsolute straight line
mm mm m³/h of pipe of bend pieces m
0 30
1 26
300 0.1 2550 0.0611) 0.211)
2 22
3 18
1) zeta value (ζ)

Esprit 770 Dynamic Power – 5


Esprit 770 Dynamic Power Planning Manual

Device cooling
Cabin or studio air is drawn in beneath the front panel (1) of the lower part of the sunbed 3 2
and over the filter mats in the canopy (2) (inlet air) in order to cool the equipment.
The inlet air is first cleaned in a filter, then fed past the hot UV low-pressure and high-
pressure lamps and finally expelled as warm exhaust air via the central exhaust air
bracket (3) at the rear of the sunbed.
Esprit 770

1 15320 / 0

Surround cooling
Surround air ventilation for the user is provided automatically. The intensity is adjusta-
ble in 9 steps. Cabin or studio air is drawn in and used for cooling.
The air is fed through several nozzles over the whole length in the middle of the canopy.
In the head area there are two air nozzles that can be switched on separately.
Studio air is also supplied via the air inlet slots beneath the front panel of the sunbed
base and fed to two nozzles at feet level at the lying surface height, thus surrounding
the body with cooling air.
The user can have a pleasant cooling mist (AQUA FRESH) sprayed from the outer noz-
zles in the body area.
Depending on the equipment, an air conditioner enables the additional climate control
of the bed surface and the body air. 15321 / 0

With the optionally available air conditioning unit (Climatronic), the user can pre-select
the temperature of the bed surface and the body air according to his needs.

6 – Esprit 770 Dynamic Power


Planning Manual Esprit 770 Dynamic Power

Exhaust air accessories


Connection to a central exhaust system is possible upwards, upwards right, upwards 5 2 3 4 3
left and to the rear.
The apertures intended for this purpose are located above the central exhaust air
bracket.

Corrugated pipe 1

Suitable device exhaust is possible with an exhaust pipe up to 10 metres in length (with-
out 90° bend). An auxiliary fan is required for exhaust pipes longer than 10 metres.

Esprit 770
Smooth pipe
15322 / 0
Suitable device exhaust is possible with an exhaust pipe up to 30 metres in length (with-
out 90° bend). An auxiliary fan is required for exhaust pipes longer than 30 metres.

Warm air recycling


Warm air recycling is a technically advanced, secure device which feeds part of the hot
cooling air back to the studio via a motor-controlled air choke. A thermostat provides
fully automatic control of the studio temperature, between 15 °C and 25 °C as required.
The exhaust air bracket and warm air recycling can also be retrofitted.

Item Accessory parts Article No. Notes


1 Central exhaust air bracket Brilliant Silver 100000890 With connection possible for exhaust air pipes
with warm air recycling, thermostatically con- (∅ 300 mm) on the top, top right, top left and to the rear
trolled including connector piece, see Item 4
Central exhaust air bracket Brilliant Silver, but 100001061
without warm air recycling
2 90° Pipe bend in Brilliant Silver 100001292 For inlet and exhaust air ducting to right, left or to rear,
plus tube adapter for direct connection to central
exhaust air bracket [possible with tube (∅ 300 mm)]
3 Corrugated pipe (∅ 300 mm, 6 m length, 34502800 –
flexible, grey) including 2 pipe clamps
4 Corrugated pipe connector piece 34502700 For connecting two corrugated pipes
(∅ 300 mm)
5 Connector bracket for corrugated pipe 34503600 Connection of the corrugated pipe, e.g. to a canal
(∅ 300 mm)
6 Exhaust air adapter in black (not shown) 34526600 For double rear wall

Esprit 770 Dynamic Power – 7


Esprit 770 Dynamic Power Planning Manual

Electrical connections

Mains supply line included


Electr. control line none
Line for external music and channel selection none

Sound system
Esprit 770

Description: Article No. Notes


3D sound unit1) with shoulder tanner 100000857 re-fittable accessory
Audio wiring set 50000060 with channel selection
Audio wiring set 50000061 w/o channel selection
1) includes Voice Guide, MP3 dock-in and SD card slot

Controls

Control Article No. Notes


MCS III plus hand-held remote control 34010600 with chip card terminal
MCS IV plus 34010400 with electronic coin tester
MCS VI 34009700 with electronic coin tester + chip card terminal
Studio Pilot 34009900 with electronic coin tester + chip card terminal
Studio Manager 34529000 software

Air conditioner
Equipment variant: Climatronic for support panel and Surround Cooling with fully integrated climate control of body cooling; Cabin
climate control via body cooling run-on (temperature-controlled), no re-fitting possible.

AQUA FRESH AROMA system


Equipment variant (Aroma and body cooling for the user), no re-fitting possible.

IR interface
Standard equipment: Access to the device data with a hand-held unit (Palm).

IQ sensor
Equipment variant, re-fitting possible.
Further information about the IQ sensor, see Esprit 770 Dynamic Power IQ.