You are on page 1of 4

www.ecomanonline.

com

POWER SYSTEM ANALYSIS & CALCULATIONS IN ELECTRICAL NETWORKS USING ETAP POWER STATION

ON SITE TRAINING
SAVE over 50% by having an EcoMan workshop presented at your premises. Customise the training to YOUR workplace. Have the training delivered when and where you need it. Contact us for a FREE proposal. Group bookings of three or more delegates, qualify for a 10% discount. Book and pay by Before the event start date 4 weeks ahead to get the early bird discount

EcoMan has always been a great place to work but we have worked very hard during the last two years to make it even better. We have recruited a number of well trained, highly motivated innovative managers and trainers to cope with our ever increasing project demands. We are committed to global uni cation of work practice and standards, o ering template solutions to regional o ces and clients alike. And we have implemented a program of high-involvement innovation through policies which: Make people management our highest priority Link sta training to global and regional business planning Install TEAM structures formally train our leaders to assist quicker TEAM cohesiveness. Focus on TEAM work rather than individual tasks through the incorporation of project management concepts Shift focus to knowledge management rather than task management because we see our people as 'assets' to be cultivated rather than 'labour costs' to be minimized

w w w . e c o m a n o n l i n e . c o m I E-mail: info@ecoman-uae.com I Tel. : + 9 7 1 2 6 2 6 3 3 2 6 I Fax : + 9 7 1 2 6 2 6 2 3 0 0

EcoMan provides world-class sessions on topics spanning the industry, from Exploration & Production to Surface Facilities, HSE, Petroleum Business, and Soft Skills EcoMan makes it easier with one-stop convenience to meet all your training needs. contact us.

Seminar Description
Power system equipment must withstand not only the rated voltage, which corresponds to the highest voltage of a particular system, but also expected short level. Accordingly, it is necessary to set protective relays based on these results obtained from short circuit study. One of hot issues now related to these is arc flashing study which is mainly based on the studies of short circuit and relay co-ordination as well. All these three issues should be dealt as integral parts & bulk. Power System Analysis means verifying the adequacy of the power distribution system and its components recognize coordination related disturbances and outages and collecting the required data to perform a detailed required study. The continuity and quality of electricity delivered safely and economically by todays and futures electrical power networks are important for both developed and developing economies. The correct modeling of power system equipment and correct fault analysis of electrical networks are pre-requisite to ensuring safety and they play a critical role in the identification of economic network investments. Environmental and economic factors require engineers to maximize the use of existing assets which in turn require accurate modeling and analysis techniques

Seminar Objective
On successful completion of this course, participants will be able to: Exploring the powerful capabilities of ETAP Power Station from OTI. Understand importance of power system modeling Understand the need for calculation the short circuit current. Manual calculation of short circuit using simple methods like MVA method, P.U. system, etc Balanced & unbalanced power flow analysis. Voltage drops & Cable sizing. Transformer MVA Sizing. Analyze the motor starting/acceleration either static or dynamic. Switchgear rating (breaking & making capacities). Importance of arc flashing and relay co-ordination studies from operation & safety point of view. Design of S/S grid Earthing using ETAP. Test cases simulation using computer softwares (ETAP 7.00).

Seminar Certificate
EcoMan certificate will be issued to all attendees completing minimum of 75% of the total tuition hours of the workshop.

Who Should attend?


This course is intended for anyone who must perform calculations, provide settings or approve the work performed by others. The trainee should be a graduate engineer or have the equivalent practical work experience in electrical power systems. i.e. Consulting Engineers. Electrical Engineers. Project Engineers. Maintenance Engineers. Commissioning & testing Engineers. Training Methodology The course is designed to maximize delegate benefit from the outset. The goals of each participant are discussed to ensure their needs are fulfilled as far as possible. Questions are encouraged throughout particularly at the daily wrap up sessions. This provides opportunities for participants to discuss specific issues and if possible find appropriate solutions. Case studies are employed to highlight particular points and appropriate video materials used to illustrate particular conditions. Understanding system design and limitations is fundamental to ensuring adequate design & specification activities are undertaken. Moreover, some simulations will be utilized during course sessions using world trade available softwares (ETAP power station).

w w w . e c o m a n o n l i n e . c o m I E-mail: info@ecoman-uae.com I Tel. : + 9 7 1 2 6 2 6 3 3 2 6 I Fax : + 9 7 1 2 6 2 6 2 3 0 0

Seminar Agenda
Overview of ETAP Capabilities & Limitations. One-Line Diagram/One line View (OLV). Creating & Merging different revisions, presentations & configuration Scenario, Study & Project Wizards. Crystal Reports & Customizations. AC & DC Element Descriptions. Load modeling. Add, updating and remove from ETAP library. Electrical systems modeling and fundamentals. Load flow (balanced & unbalanced) analysis. Load Flow & Cable sizing. Transformer sizing. Benefits of calculated short circuit currents. Introduction to Fault current Calculations in brief. Breaking & making currents. Per unit systems. Different typical values of positive, negative & zero phase sequence impedances for unbalance faults. Manual Calculations of Isc by MVA Method. Calculation of Isc by Impedance method. Calculation of Isc by symmetrical components. Calculations as defined & recommended by IEC/ANSI standards. Short Circuit Studies (Fault-Levels Switchgear/Fuse Rating). Typical cases for switchgear sizing. Relay co-ordination & Arc Flashing studies. Coordination Fundamentals Procedures Data Collection Plotting Time/Current Curves Relay Coordination Intervals Equipments damage curves for cables, transformers, etc... System Modeling for Device Coordination Study ETAP Star (Device Co-ordination/selectivity). System earthing (Solid, resistance & reactance or even ungrounded systems) Substation grounding grid design & Calculations. Motor Parameter Estimation. Motor Acceleration Analysis (Dynamic & Static). Different test simulation cases using ETAP power station version 7.00. Course Evaluations & Summary

w w w . e c o m a n o n l i n e . c o m I E-mail: info@ecoman-uae.com I Tel. : + 9 7 1 2 6 2 6 3 3 2 6 I Fax : + 9 7 1 2 6 2 6 2 3 0 0

REGISTRATION / INQUIRY DETAILS


Complete & send by Fax / Mail to address given below Please register me on the following programmes: Please send me more information on the following programmes PROGRAMME TITLE DATES

SPONSOR
We wish to register this delegate for the course mentioned above and undertake to pay his/her fee. Name : ............................................................................................ Designation : .................................................................................. Company : ...................................................................................... Mailing Address: .......................................................................... ......................................................................................................... Telephone : .................................................................................... Fax : .................................................................................................. Email : ..............................................................................................

PERSONAL DETAILS
First Name (Mr./Ms) : ................. .... ............................................ Family Name : ................................................................................ Designation : ........................................................................................ Company: ............................................................................................. Mailing Address: ................................................................................ ................................................................................................................... Telephone: ..................................................................................... Fax : ................................................................................................. Email : .............................................................................................

TYPE OF PAYMENT
Please nd enclosed a cheque made payable to EcoMan Please invoice me Please invoice my company (Sponsor)

SEMINAR
DOCUMENTATION High Quality material has been prepared by the Seminar Leader for distribution to delegates. In addition a special note pad to facilitate note taking will be provided. CERTIFICATES A Certicate of Attendance will be issued to those who attend and successfully complete the programme. FEES The Fee for the seminar includes instruction materials, documentation, lunch, coee / tea breaks. HOTEL ACCOMMODATION EcoMan has negotiated special rates for a limited number of rooms in the hotel. Early registration will help to secure a room at the reduced rate.

FOUR EASY WAYS TO REGISTER

Telephone: +971 2 626 33 26 to provisionally reserve your place.

Fax your completed registration form to: +971 2 62 62 300

E-mail us : E-mail: info@ecoman-uae.com

Complete and return the booking form with cheque to: EcoMan P.O. Box: 31441, Abu Dhabi, U.A.E.

w w w . e c o m a n o n l i n e . c o m I E-mail: info@ecoman-uae.com I Tel. : + 9 7 1 2 6 2 6 3 3 2 6 I Fax : + 9 7 1 2 6 2 6 2 3 0 0

You might also like