Direction for use


Model See the label Indications The cable is indicated for use for signal transferring of patient monitor, EKG, EEG machine Contraindication Do not put the sensor on the burned site, not suitable for the one who is allergy for the plastic like TUP, PVC, TPE, ABS. Structure: It consists of instrument connector, ECG trunk cable, yoke, leads set, terminal. All material is made of medical PVC and TPU. Plug made with golden plated brass. Notice: a) Firstly ensure choosing the correct electrode, suitable for the right ECG cable, Change the electrode or ECG cable if some interference on the transferring signal b) Ensure the electrode put as wanted c) A few machine require earth cable, connect with it when the machine requires before using d) This cable just used for medical equipment, check carefully to see if it is compatible; if not, it will decrease the test accuracy, even break the cable or machine. e) Refer to the manual before use it. Instructions for Use 1, Connect the yoke connector with the leadwire, then put the plug in the equipment connector to ensure reliable connection. 2, Plug the cable terminal in the suitable electrode (some cables will require disposable electrode, to ensure accuracy, it is suggested not to use it again.) 3, Use the physiological saline clean on the body, fix the electrode on the body. (Notice: put the electrode on the right site of the patient without error) 4, Start the machine to test it. 5 May need leadwires direction according to the machine (refer to the machine manual) To clean or care the sensor a) Check it carefully to see if broken and clean it. b) Clean: Saturate a clean, dry gauze pad with the cleaning solution, wipe all surfaces of the cable with this gauze pad. Wipe all surfaces of the cable with this gauze pad. c) Disinfection: use solution to disinfect cable like isopropyl alcohol. Caution: Do NOT sterilize by irradiation or steam. d) Sterilization: Sterilize the cable by ethylene oxide (ETO) on the condition of maximum temperature of 50 (122F) then ventilation according to the suggestion of machine manufacturer. Time Limited Suggest changing the cable since having used for 6 months. If want to use longer, kindly check carefully before use.

Expert of medical accessories

www.chino86.com

Storage Put the products into one sealed bag after clean, disinfect, dry the ECG cable. Storage Environment requirement: Temperature (Storage/Transportation): -10~+40 Humidity: 0~80% Condensing Hyperbaric Pressure (Storage/Transportation): 86 Kpa~106Kpa Warranty As informed by the representative. Expiry: See label (stop using since ex-factory for 24 months.)

You might also like