Sr No Particulars Specification
Date:- 06/12/2012 1 2 3 4 5 6 7 8 9 10 11 12 13 Envirment Condition Voltage Variation Frequency Variation Performance Dimensions Rating Enclosure Frame Insulation Rotor Type Of Construction Cooling & Ventillation External Cooling Fan Highly Corrosive, Caustic & Acid Fumes 415V +/- 10% 50 Hz +/- 5% Performance should Confirm to IS:325, IEC 34-PART1 Dimensions should confirm to IS:4691 , (For Foot Mounted), IS: 2223 ( For Flange Mounted) Cont.Duty at 50 deg C Ambient Duty-S1 IP55 degree of protection as a standard, feature IS:4691 & IEC 34 part - 5 Rugged Construction Class 'F' with temperature rise restricted, to Class 'B' Winding.Overheating to be, coated with EPOXY GEL COAT-Dr.Beck DIE CAST, Shaft center should be provided with tapped hole as per standards IMB as per IS 2253 & IEC 34 part 7, with single shaft CONSTRUCTION Type of cooling is IC 0141and as per IS:6362 Al.Die Cast Aluminium Location Of Terminal Box is on top of the Housing. The Terminal boxes should be rotated in steps of 90 deg & should be suitable for proper Aluminium cable termination. Six Winding leads to be brought out & terminated on a suitable terminal block. Tin Plated Material. Terminal Plate DMC only. Terminal Box Size should be considered one size Higher to the standard size Re-arranging facility should be provided for DE & NDE Bearings, with nipple at the top of the end cover. All motors should be provided with minimum 3 earthing terminal one in the terminal box and two on the stator Housing. Efficiency values of motors at 100% rated o/p should remain unchanged up to 60% of rated o/p utilisation. The Motor should have the maximum Efficiency (Efficiency Figures to be approved before placement of the order.) Acid and Alkali resistant. 631 Test Certificates and Performance Curves Should be supplied alogn with Motors IE 3 Class
14
Terminal Box
15 16
17
Earthing Systems
18
Efficiency
19 20 21
22 23 26 28 30 31 32 33
Routine Test Service Factor Foundation Arrangement T/S speed curve Speed Range Bearing Series-63 Inverter Duty Motors Accessories
For all Motors 1-1.2 Suitable for Both Frame For Inverter duty motors-1/20 base speed of IGBT Power/ Constant torque at any speed For Inverter Duty Motors 63 Series required on DE & NDE side Extra Cooling Fan Required. SS hardware, SS name plate with DE & NDE bearing details
Center
Date:- 06/12/2012
Vendor Remarks
Aditya Birla Cellulosic Fiber Reserch Center Dept:- Electrical Summary Of Motors For 2TPD Project
Date:- 06/12/2012
General Motors
Sr. No
1 2 3 4 5 6 7 8 9
HP
1 2 3 5 5 7.5 10 12.5 20
RPM
1440 2900 1440 1440 2900 2900 2900 1440 2900
Mounting
FT FT FT FT FT FT FT FT FT
Pole
4 2 4 4 2 2 2 4 2
Starter
DOL DOL DOL DOL DOL DOL DOL DOL DOL
Quantity
1 4 4 7 1 3 1 3 1
HP
3 3
RPM
2900 960
Mounting
FT FT
Pole
2 6
Starter
VFD VFD
Quantity
2 1
3 Total Motors
28