INDUSTRIAL CONNECTORS

CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT- OUTS 11KV 33KV CABLE JOINTS & CABLE TERMINATIONS FURSE EARTHING www.cablejoints.co.uk Thorne and Derrick UK Tel 0044 191 490 1547 Fax 0044 191 477 5371 Tel 0044 117 977 4647 Fax 0044 117 9775582

INDUSTRIAL CONNECTORS

A-BELCO

Engineering Solutions
Formerly Reyrolle

Design to Manufacture

Introduction & Group History

INDUSTRIAL CONNECTORS

A-BELCO

A-Belco Industrial Connectors


A-Belco Industrial Connectors is a specialist manufacturer of industrial plugs, sockets, connectors and combination units for the control and distribution of electrical power. The range includes EASIGO, CEEGO, HEAVY DUTY, FUSE and CUSTOM BUILD ranges. The Easigo range is an unrivalled product range formerly produced by Reyrolle since 1910, and manufactured to the exact same standards today by A-Belco. A-Belco Industrial Connectors are widely used in heavy duty applications where a robust product is specified.

GROUP OF COMPANIES

A-BELCO
The A-Belco Group incorporates four specialist divisions offering Electrical & Mechanical engineering excellence to a wide range of markets worldwide. A-Belco Hazardous Area A-Belco Electrical Engineering A-Belco Industrial Connectors MEP Solutions ATEX and IEC Ex approved Explosion proof electrical equipment Low voltage electrical distribution and switchgear solutions Heavy Duty plugs, sockets, connectors and custom build units, to BS196 and BS4343 Standards M&E prefabricated multi-service pipework modules

HISTORY
1910 1947 1991 Easigo Range manufactured by A. Reyrolle & Co (Hebburn) Reyrolle Industrial Accessories (RIA) formed; Easigo Range production moves to Ashington Acquisition of RIA from Rolls Royce Plc Company renamed BALS Industrial Accessories Reyrolle BS196 plugs, sockets and connectors range retained BALS Engineering Group Joint Ventures formed: Cortem UK & Scame UK Easigo, Ceego, Heavy Duty and Fuse Ranges now marketed via Scame UK. BALS high voltage division sold to GE; low voltage division retained BALS renamed A-Belco MEP Solutions formed A-Belco Group re structured to bring synergy and facilitate growth strategies: A-Belco Ltd A-Belco Electrical Engineering A-Belco Hazardous Area A-Belco Industrial Connectors MEP Solutions Ltd

1994 1999 2001 2002 2006

Original Range, 1910

INDUSTRIAL CONNECTORS

A-BELCO

Contents

Easigo Range
3 - 10

Ceego Range
11 - 14

Heavy Duty Range


15 - 16

Fuse Range
17 - 19

Custom Build
20

Dimensional Drawings
21 - 27

Index
28 - 29

Easigo Reyrolle

INDUSTRIAL CONNECTORS

A-BELCO

EASIGO (Formerly Reyrolle)


The Easigo range of industrial plugs and sockets BS196.1961 is now manufactured by A-Belco. The BS196.1961 Easigo range continues to provide a comprehensive choice of protected type non-reversible single phase plugs, sockets and switched interlocked sockets in current ratings from 5, 15 and 30 amperes. Easigo also includes 3-phase fittings rated from 15 to 60 amperes using the same principles of construction and safety as defined in BS196. The robust design combines cast metal and high performance moulded materials making them suited for the most arduous of environments - typical industries where this product is well entrenched are Power Stations, Steel Mills, Distilleries and Breweries, Chemical Plants, Railways and Airports not only in the United Kingdom but worldwide.

EASIGO - FEATURES
Range of protected type non-reversible plugs and sockets with scraping earth connections 5-60 Amperes. The EASIGO range comprises single phase plugs and sockets to BS196 and also three-phase with our own arrangement of pin centres. The fittings have die cast zinc alloy casings and insulated materials are used for the back casings of the angle entry plugs and the spring flap covers of the 5 and 15 ampere 2 pole flush sockets. These materials have been specifically selected to withstand the arduous conditions encountered in industrial applications.

BS196 FITTINGS (5-30 AMPERES)


In 1930, BS196 was issued as the first British Standard covering industrial plugs and sockets. The standard was revised in 1961 at which time many of the innovations introduced by ourselves since 1930 were included e.g. keys and keyways for voltage discrimination and fused plugs. The standard covers single phase fittings in current ratings of 5, 15 and 30 amperes.

THREE PHASE FITTINGS (15-60 AMPERES)


Until 1968, when BS4343 was issued, no British Standard existed to cover the requirement for three-phase plugs and sockets. In similar manner to other manufacturers we produced fittings with their own unique pin configurations.

DEGREES OF INGRESS PROTECTION


The accessories supplied by A-Belco conform to the ingress protection requirements specified by Clause 27, Section 5 of British Standard 196: 1961. Flush sockets 5-15 ampere, single phase have increased ingress protection to IP55. However, if fittings are being used in exposed outdoor installations, it is recommended that additional means of protection, such as canopies or enclosures, should be provided. The SCRAPING EARTH feature provided by permanently resilient tongues fitted to the socket and connector casings ensures that the earth connection is made before and breaks after the main circuit connections and eliminates the need for a separate earth pin and tube. Only BS196 offers the facility of industrial ring socket outlets which will prevent the insertion of an unfused plug. A range of appropriate fused plugs is available. The EASIGO range of switch sockets incorporates mechanical interlocks which are designed so that the socket contacts are never accessible when live. The plug can only be withdrawn from the socket with the switch in the OFF position and the switch cannot be closed until the plug is fully inserted. Some of the switch sockets can be provided with RCCB protection.
Screw in fuse pin Colour coding

Ring main sockets Shrouded plug pins Scraping earth Deeply recessed contact tubes Robust construction

INDUSTRIAL CONNECTORS

A-BELCO

Easigo Reyrolle

The pilot contacts provided are intended for use with continuously monitored earth proving devices, but they can be used with any protective system requiring an insulated contact. The pilot contact pin in the plugs is shorter in length than the phase pins and so makes after and breaks before the phase contacts. The current carrying capacity of the pilot contact is: 15 amp size 30 amp size 10 amps 25 amps

The pilot contact is not the earth contact of the fitting. Switch sockets can be supplied incorporating a pilot contact for use in multi-outlet earth monitoring systems which require the monitoring circuit to be maintained when the plug is removed. These have an auxiliary contact on the rotary switch which opens before the main contacts close and closes after the main contacts open. All switch sockets incorporate double pole or triple pole double break switches. The 5 and 15 ampere 2 pole switches are suitable for A.C. and D.C. while the remainder are suitable for A.C. systems only. The units containing mercury switches are suitable for A.C. and D.C. systems and must be mounted vertically.

EASIGO - FEATURES
Plug and socket key and keyway positions for non-interchangeability. In addition to the differences in the size of the casings and the size and position of the contact pins, BS196: 1961 requires that undesirable interchangeability between accessories shall also be prevented by the use of keys and keyways on the plug and socket casings. The key and keyway combinations which have been established for different systems are as shown here and the diagram below. The corresponding key positions of the plug or appliance inlet when looked at from the front are the opposite to those shown below.

COMMONLY USED CONFIGURATIONS


Voltage 25 50 110 240 Frequency 50 50 50 50 Frequency 50 other than 50 (e.g. 60) other than 50 (e.g. 60) other than 50 (e.g. 60) other than 50 (e.g. 60) D.C. D.C. D.C. D.C. Keyway 1 None None None None Keyway 2 0 135 45 None Keyway 3 180 315 225 None Keyway 3 210 300 300 300 300 240 240 240 240 Earth Yes Yes Yes Yes Earth Yes Yes Yes Yes Yes Yes Yes Yes Yes Code AN XK DR None Code CQ AJW XJW DJW CJW AES XES DES CES
for ed erv eys Rescket K o S

25V 50~

SP F
B
15

used

~ 50

V 50

337

.5

30 0

nonreversibility recess

30
45

11 0V
D

50 ~

25 0V 50 ~

31 5

N
0

spare

Normal scraping-earth position

285

270

255

24

* Included for situations where complete non-interchangeability is essential. Original design to BS196: 1930.

THREE-PHASE PLUGS AND SOCKETS

In addition to the standard 415 volt arrangements, the three-phase (3 pole) fittings are also available as types AN, XK and DR. In this connection the symbols are used for the purpose of convenience and do not necessarily conform with the appropriate voltage and frequency laid down for single phase fittings in BS196: 1961. Code AN Code XK Code DR Normally for 125V 200Hz systems Normally for 50V 50Hz systems Normally for 110V 50Hz systems

COLOUR CODING
In addition to the above key and keyway system, the 5 and 15 ampere 2 pole fittings are colour coded as follows: 240 volt 110 volt 50 volt 25 volt blue yellow white violet

13

22

.5 175

180

195

21

0V 11

~ 50

AC

DC

ot he rt ha n5 0~
6V 5 0~
12V

DC
12 ~ V 50

ALTERNATIVE CONFIGURATIONS
Voltage m * 240 m 25 m m
n5 0~

E
60

Keyway 1 Keyway 2 None 30 0 120 315 45 30 0 315 45 30 120 120 120 60 60 60 60

spare
50~

Normal scraping-earth position

75
90

50 110 240

105
12 0

H
J

6V 5

0~

AC
50 V 50

oth

er

tha

m 25 m 50 m 110 m 240

25 0V 50 ~

for ed erv eys Rescket K So

DP fu sed

25V 50~

m Only available with EASIGO flush socket outlets with spring flap covers & angle entry plugs. Fused plugs must not be used in D.C. systems

CURRENT RATINGS
The plugs and sockets can carry currents in excess of their stated capacity. The maximum continuous ratings are as follows, provided that adequate cabling is used: 5 ampere 15 ampere 30 ampere 60 ampere 10 ampere max 20 ampere max 40 ampere max 80 ampere max
4

Easigo - Plugs and Sockets

INDUSTRIAL CONNECTORS

A-BELCO

Plugs Straight Angled

Sockets Surface

Amps 5

Poles 2P+E

Volts/ Colour 25 50 110 240 25 50 110 240 25 50 110 240 50 110 125 415 50 110 125 415 25 50 110 240 25 50 110 240 50 110 125 415 50 110 125 415 240 240 415 415 415

15

2P+E

2P+E with pilot 3P+E

Unfused 3082AN 3082XK 3082DR 3082 3290AN 3290XK 3290DR 3290

Unfused with retaining ring 6042AN 6042XK 6042DR 6042 6130AN 6130XK 6130DR 6130

200Hz

3P+E with pilot 30 2P+E

3295XK 3295DR 3295AN 3295

6135XK 6135DR 6135AN 6135

200Hz

2P+E with pilot 3P+E

200Hz

3P+E with pilot 60 2P+E 2P+P+E 3P+E 3P+P+E 3P+N+E

200Hz 3570 3910 3590 3930 3940

Unfused 3092AN 3092XK 3092DR 3092 3302AN 3302XK 3302DR 3302 3603AN 3603XK 3603DR 3603 3307XK 3307DR 3307AN 3307 3680XK 3680DR 3680AN 3680 3452AN 3452XK 3452DR 3452 3730AN 3730XK 3730DR 3730 3457XK 3457DR 3457AN 3457 3780XK 3780DR 3780AN 3780

Single Fuse 1515AN 1515XK 1515DR 1515 1110AN 1110XK 1110DR 1110 1310AN 1310XK 1310DR 1310 Straight with 3 fuses

Double Fuse 1615AN 1615XK 1615DR 1615 1210AN 1210XK 1210DR 1210 1410AN 1410XK 1410DR 1410 1715XK 1715DR 1715AN 1715

Unfused with retaining ring

1830AN 1830XK 1830DR 1830

1930AN 1930XK 1930DR 1930

6230AN 6230XK 6230DR 6230

6235XK 6235DR 6235AN 6235

3017AN 3017XK 3017DR 3017 3221AN 3221XK 3221DR 3221 3600AN 3600XK 3600DR 3600 3227XK 3227DR 3227AN 3227 3650XK 3650DR 3650AN 3650 3402AN 3402XK 3402DR 3402 3700AN 3700XK 3700DR 3700 3407XK 3407DR 3407AN 3407 3750XK 3750DR 3750AN 3750

With Screw Cap 6010AN 6010XK 6010DR 6010 6100AN 6100XK 6100DR 6100

6105XK 6105DR 6105AN 6105

6200AN 6200XK 6200DR 6200

6205XK 6205DR 6205AN 6205

3565** 3905** 3585** 3925/P** 3925**

Fuse links for 1715 series plugs see p9. ** Push on Cover

INDUSTRIAL CONNECTORS

A-BELCO

Easigo - Sockets, Connectors And Appliance Inlets

Sockets* Flush with spring flap cover

Connectors Straight Angled

Appliance Inlets Surface Flush with spring flap cover

Poles Amps 5 2P+E

15

2P+E

2P+E with pilot 3P+E

3P+E with pilot 2P+E

30

2P+E with pilot 3P+E

3P+E with pilot 60 2P+E 2P+P+E 3P+E 3P+P+E 3P+N+E

Volts/ Colour 25 50 110 240 25 50 110 240 25 50 110 240 50 110 125 200Hz 415 50 110 125 200Hz 415 25 50 110 240 25 50 110 240 50 110 125 200Hz 415 50 110 125 200Hz 415 240 240 415 415 415

Ring main 2000AN 2000XK 2000DR 2000 2050AN 2050XK 2050DR 2050 2100AN 2100XF 2100DR 2100 2150AN 2150XK 2150DR 2150 2200XK 2200DR 2200AN 2200 2250AN 2250XK 2250DR 2250 2300AN 2300XF 2300DR 2300 2350XK 2350DR 2350AN 2350 2400XK 2400DR 2400AN 2400 2500 2550 2600 2650/P 2650 2000FAN 2000FXK 2000FDR 2000F 2050FAN 2050FXK 2050FDR 2050F 2100FAN 2100FXK 2100FDR 2100F

2250FAN 2250FXK 2250FDR 2250F

For interlock plugs 2015AN 2015XK 2015DR 2015 2065AN 2065XK 2065DR 2065 2115AN 2115XK 2115DR 2115 2165XK 2165DR 2165AN 2165 2215XK 2215DR 2215AN 2215 2265AN 2265XK 2265DR 2265 2315AN 2315XK 2315DR 2315 2365XK 2365DR 2365AN 2365 2415XK 2415DR 2415AN 2415

With screw cap 6070AN 6070XK 6070DR 6070 6160AN 6160XK 6160DR 6160 6630AN 6630XK 6630DR 6630 6165XK 6165DR 6165AN 6165

With retaining ring 6050XK 6050DR 6050 6140AN 6140XK 6140DR 6140 2070AN 2070XK 2070DR 2070

6690XK 6690DR 6690AN 6690 6260AN 6260XK 6260DR 6260 6740AN 6740XK 6740DR 6740 6265XK 6265DR 6265AN 6265 6790XK 6790DR 6790AN 6790

6145XK 6145DR 6145AN 6145

6240AN 6240XK 6240DR 6240

6245XK 6245DR 6245AN 6245

* Ring main sockets only accept fused plugs

Easigo - Interlocked Switched Sockets

INDUSTRIAL CONNECTORS

A-BELCO

Interlocked Switched Sockets* Sparkless Units Micro Switch Mercury Switch

Amps 5

Poles 2P+E

15

2P+E

2P+E with pilot 3P+E

3P+E with pilot 30 2P+E

2P+E with pilot 3P+E

3P+E with pilot 60 2P+E 2P+P+E 3P+E 3P+P+E 3P+N+E

Volts/ Colour 25 50 110 240 25 50 110 240 25 50 110 240 50 110 125 200Hz 415 50 110 125 200Hz 415 25 50 110 240 25 50 110 240 50 110 125 200Hz 415 50 110 125 200Hz 415 240 240 415 415 415

With auxiliary contacts

Double Pole 10577AN 10577XK 10577DR 10577 10586AN 10586DR

Ring Main 10577FAN 10577FXK 10577FDR 10577F

Single Pole 10555AN 10555XK 10555DR 10555 10565AN 10565XK 10565DR 10565

10615DR 10600AN 10600XK 10600DR 10600 10610XK 10610DR 10610 10620XK 10620DR 10620 10630AN 10630XK 10630DR 10630 10640AN 10640XK 10640DR 10640 10650XK 10650DR 10650 10660XK 10660DR 10660 10670 10675 10680 10685/P 10685 10602AN 10602XK 10602DR 10602

Ring Main 10555FAN 10555FXK 10555FDR 10555F 10565FAN 10565FXK 10565FDR 10565F

Double Pole 10575AN 10575XK 10575DR 10575 10585AN 10585XK 10585DR 10585

Ring Main 10575FAN 10575FXK 10575FDR 10575F 10585FAN 10585FXK 10585FDR 10585F

10622XK 10622DR 10622

10642AN 10642XK 10642DR 10642

10662XK 10662DR 10662

* Ring main sockets only accept fused plugs

INDUSTRIAL CONNECTORS

A-BELCO

Easigo - Interlocked Switched Sockets and Plugs

Interlocked Switched Sockets* With RCD protection

Plugs - Interlocked Straight Angled

Amps 5

Poles 2P+E

15

2P+E

2P+E with pilot 3P+E

3P+E with pilot 30 2P+E

2P+E with pilot 3P+E

3P+E with pilot 60 2P+E 2P+P+E 3P+E 3P+P+E 3P+N+E

Volts 25 50 110 240 25 50 110 240 25 50 110 240 50 110 125 200Hz 415 50 110 125 200Hz 415 25 50 110 240 25 50 110 240 50 110 125 200Hz 415 50 110 125 200Hz 415 240 415 240 415 415 415

Single Pole 10505AN 10505XK 10505DR 10505 10515AN 10515XK 10515DR 10515

Ring Main 10505FAN 10505FXK 10505FDR 10505F 10515FAN 10515FXK 10515FDR 10515F

Fused F Unfused U

RES1151DR RES1151 RES1152DR RES1152 RES1153DR RES1153 RES1154DR RES1154 RES1301DR RES1301 RES1302DR RES1302 RES1303DR RES1303 RES1304DR RES1304 RES1600 RES1601 RES1602 RES1603 RES1604 RES1605 3570 3571 3910 3590 3930 3940

1765XK 1765DR 1765AN 1765

F F F F

Unfused 7200AN 7200XK 7200DR 7200 7210AN 7210XK 7210DR 7210 7220AN 7220XK 7220DR 7220 7230XK 7230DR 7230AN 7230 7240XK 7240DR 7240AN 7240 7250AN 7250XK 7250DR 7250 7260AN 7260XK 7260DR 7260 7270XK 7270DR 7270AN 7270 7280XK 7280DR 7280AN 7280

Single Fuse 1525AN 1525XK 1525DR 1525 1120AN 1120XK 1120DR 1120 1320AN 1320XK 1320DR 1320

Double Fuse 1625AN 1625XK 1625DR 1625 1220AN 1220XK 1220DR 1220 1420AN 1420XK 1420DR 1420

1880AN 1880XK 1880DR 1880

1980AN 1980XK 1980DR 1980

U U U U U

Fuse links for 1765 series plugs see p9. * Ring main sockets only accept fused plugs

TYPICALLY USED IN AIRCRAFT INDUSTRIES


Angle Entry Plug Interlocked Switch Socket Flush Mounting Socket Outlet

Amps 5A

Poles 4P+E

Volts 25 50 110 240

7204-AN 7204-XK 7204-DR 7204

Micro Switch 10576-AN 10576-XK 10576-DR 10576

Mercury Switch 10574-AN 10574-XK 10574-DR 10574

2004-AN 2004-XK 2004-DR 2004

Easigo - Conduit Boxes, Multi-Socket Outlets and Fuse Pins

INDUSTRIAL CONNECTORS

A-BELCO

CONDUIT BOXES
Socket Types Surface Flush Push On Covers

Amps 5 15

30

60

Poles 2P+E 2P+E 2P+P+E 3P+E 3P+P+E 2P+E 2P+P+E 3P+E 3P+P+E All

For circular sockets 611 621 631 631 651 651 651 651 651

For square sockets 711 721 721 721 741 741 741 741 741 661

715 725 725 725 745 745 745 745 745

For circular sockets 3162 3352 3353 3353 3423 3413 3423 3423 3423

MULTI-SOCKET OUTLETS
Insulated Housing 2 gang 3 gang Metal Housing 2 gang

Amps 5

Poles 2P+E

15

2P+E

15

2P+E with pilot

Volts 25 50 110 240 25 50 110 240 25 50 110 240

MSS0522AN MSS0522XK MSS0522DR MSS0522 MSS1522AN MSS1522XK MSS1522DR MSS1522

Ring Main MSS0522FAN MSS0522FXK MSS0522FDR MSS0522F MSS1522FAN MSS1522FXK MSS1522FDR MSS1522F

MSS0523AN MSS0523XK MSS0523DR MSS0523 MSS1523AN MSS1523XK MSS1523DR MSS1523

6530AN 6530XK 6530DR 6530 6540AN 6540XK 6540DR* 6540 6550AN 6550XK 6550DR 6550

Ring Main 6530FAN 6530FXK 6530FDR 6530F 6540FAN 6540FXK 6540FDR* 6540F 6550FAN 6550FXK 6550FDR 6550F

* 6540DR & 6540FDR are CGB approved

FUSE PINS
Plug rating amps 5 15 Fuse pin rating amps 5 10 5 10 15 20 15 30 Cat. No 1055 1060 1005 1010 1000 1020 1034 1030

FUSE LINKS FOR 1715 & 1765 SERIES PLUGS


Rating amps 2 6 10 16 Cat. No F313 F316 F318 F319

30

INDUSTRIAL CONNECTORS

A-BELCO

Easigo - Fuse Switch Socket with Rccb Protection

DESCRIPTION
Designed for and approved by the former Central Electricity Generating Board to GDCD 238.

FEATURES
Sheet steel enclosure with durable stoved enamel grey finish to ESI 98 which has been subjected to appropriate environmental tests. Units meet IP44 specification. The units have undrilled gland plates to top and bottom, facilitating top or bottom cable entry. A die cast cover with padlocking facility gives access to the RCCB which has a tripping sensitivity of 30mA operating in a maximum of 30mS. The fuse switch is interlocked with the lid and the socket outlet. Unit is fully interlocked and cannot be switched on until the correct plug is fully inserted, nor can the plug be withdrawn on load. Provision for padlocking the switch handle in the OFF position. Units are tested at through fault level of 31.5MVA. If necessary, units can be supplied without the RCCB and solid links can be fitted in place of fuses. Units can also be provided with an earth monitoring facility in accordance with optional feature in CEGB specification. Designed to loop up to 35mm2 cables.

CEGB APPROVAL NO. EPA 177


Amps 60 Poles 3P+E 3P+N+E 3P+P+E Volts 415 415 415 Fused 12604 With RCCB 13604 13605CN 13605DX With RCCB and EMU*

15604DX

* EMU - Earth Monitoring Unit

B D F
305

AE
305

10

Dimensions A B 560 326

C 205

D 296

E 440

F 60

G 75

H 2

J 155

Max Cable Phase 35mm2

Earth Stud M8

Weight Kg 23

10

Ceego

INDUSTRIAL CONNECTORS

A-BELCO

DESCRIPTION
The CEEGO range, in both single and 3-phase, is manufactured in current ratings of 16, 32, 63 and 125 amperes. The CEEGO multi-socket outlets comprise insulated sockets mounted on an insulated box, the design and construction of which is suitable for the arduous conditions of industrial applications. The maximum load for each units is: 2 way - 32 amperes 3 and 4 way - 40 amperes Other arrangements of voltage/frequency can be provided to meet specific requirements.

CEEGO
The CEEGO range conform to EN 60309-1 and EN 60309-2 and consists of plugs, sockets, connectors, switched interlocked sockets and multi socket units. The plugs sockets and connectors are available in both IP44 and IP65 versions. The socket range has both panel and surface mounting products. The switched interlocked socket range is particularly suited to heavy industrial installation. There are units with combinations of MCB, RCD and fused protection. In addition there are special units for power station applications including earth monitoring. Twin sockets are housed in both metal and insulated casing. They can be used as trailing or wall mounting sockets. They are available in IP44 or IP65.

TWIN SOCKETS
Caravans and Marinas Normal supplies are via 16 Amp 240 Volts 2P+E (Blue) devices. Both splashproof and watertight are used dependent on location and housings. 16 Amp 110 Volt 2P+E (Yellow) devices are the norm for hand tools and temporary lighting. Splashproof units are widely used. A full range of construction site electrcal equipment s available. 32 Amp 440 Volt 3P+E (Red) 3 hour position units are the international standard. Standard units have 30mA sensitivity trip within 30mS

Construction sites

Refrigerated containers

Residual Current Circuit Breakers (RCCB)

IP PROTECTION DEGREE
Splashproof units to IP44 gve protection against solid bodies larger than 1 mm and projections of water from all directions. These devices are suitable for most indoor uses and non-continuous outdoor use. Where dust and moisture are normally present devices to IP65 should be selected. Watertight units to IP65 give protection against dust and the effect of Jets of water from all directions. Pilot pins are standard on 63A and 125A devices.

11

INDUSTRIAL CONNECTORS

A-BELCO

Ceego - Plugs And Sockets

Ceego - Plugs And Sockets PLUGS AND SOCKETS REFERENCE STANDARD: EN 60309-1 AND EN 60309-2
Spare fuse pins are available for F.R.P. series plugs 5A-1065, 10A-1061. Plugs Angled Central Entry with Grommet Fused Angled

Hz 50/60

Poles 2P+E

50/60

3P+N+E

Volts 110 110 240 240 110 415

h. 4 6 4 6

16 A IP44 P1-4h P1-6h P3-4h P3-6h

16 A IP44 RP1-4h RP1-6h

16 A IP44 FRP51-4(5A)/ FRP101-4(10A) FRP51-6(5A)/ FRP101-6(10A)

32 A IP44 P21-4h P21-6h P23-4h P23-6h

Fused Plug - with pin centres to BS EN 60309 (BS4343)


A fitting which provides localised protection for the individual piece of apparatus. An adaptation of the well-proven concept of the BS196 fuse pin. Designed and tested to recognised safety standards.

PLUGS AND SOCKETS REFERENCE STANDARD: EN 60309-1 AND EN 60309-2

Sockets* Large Square Flange Small Square Flange Large Square Flange

Hz 50/60 50/60

Poles 2P+E 3P+N+E

Volts 110 240 110 415

h. 4 6 4 6

16 A IP44 S1-4h S1-6h S3-4h S3-6h

16 A IP44 RS1-4h/A1-4h RS1-6h/A1-6h

32 A IP44 S21-4h S21-6h S23-4h S23-6h

*When panel mounting without box a special gasket is required

Metal surface mounting box for large square flange sockets CAT 721

Insulated surface mounting box for small square flange sockets Type RSI CAT CB-16G

Metal sunk box for large square flange sockets CAT 725

12

Ceego - Plugs And Sockets

INDUSTRIAL CONNECTORS

A-BELCO

Ceego - Plugs And Sockets Multi-socket Outlets


# Central entry plugs shouldbe used with these units Straight Sockets Inclined Sockets # Straight Sockets

Hz

Poles

Volts h. 110 240 4 6

50/60 2P + E

Insulated Housings 16 A 2 Way 3 Way IP44 IP44 MSS1632-4h MSS1633-4h MSS1632-6h MSS1633-6h

4 Way 3 Way 4 Way IP44 MSS1634-4h MSA1632-4h MSA1633-4h MSA1634-4h MSS1634-6h MSS1632-6h MSS1633-6h MSS1634-6h

16 A 2 Way

Metal Housings 16 A 2 Way IP44 6640-4 6640-6

2 Way IP65 6640W-4 6640W-6

PLUGS AND SOCKETS REFERENCE STANDARDS: EN 60309-1 AND EN 60309-2

Plugs with Pilot Flanged socket Plug with gland

Hz 50/60

Poles 3P+N+E

Volts 346 - 415

h. 6

32 A IP65 RS36-6h

32 A IP65 RP36-6h

PLUGS AND SOCKETS REFERENCE STANDARDS: EN 60309-1 AND EN 60309-2

Sockets Square Flange with pilots

Plugs With Gland

Poles 2P+E 3P+E 3P+N+E

Poles 2P+E 3P+E 3P+N+E

Volts 240 415 415

h. 6 6 6

63 A IP65 S42-6h S44-6h S46-6h

63 A IP65 P42-6h P44-6h P46-6h

13

INDUSTRIAL CONNECTORS

A-BELCO

Ceego - Interlock Switch Sockets to Power Station Specifications

FEATURES
Sheet steel enclosure with durable dark Admiralty grey ESI 98 finish which has been subjected to appropriate enviromental tests. Units meet IP65 specification. The units have undrilled gland plates to top and bottom, facilitating top or bottom cable entry. A die cast cover with padlocking facility gives access to the RCCB which has a tripping sensitivity of 30mA operating in a maximum of 30 mS. The fuse switch is interlocked with the lid and the socket outlet. Unit is fully interlocked and cannot be switched on until the correct plug is fully inserted, nor can the plug be withdrawn on load. Provision for padlocking the switch handle in the OFF position. Units are tested at through fault level of 31.5MVA. If necessary, unit can be supplied without the RCCB and solid links can be fitted in place of fuses. 63 ampere unit available fitted with EASIGO 60 ampere sockets. Unit meets IP44 specifications. 32A 3P+N, 63A and 125 A units can also be provided with an earth monitoring facility in accordance with optional feature in CEGB specification. Designed to loop up to 35mm2 cables.

METAL HOUSINGS REFERENCE STANDARD: EN 60309-2 BS EN 60309-2, CEE 17 - (BS 4343) Power station units meet CEGB specification GDCD 238 16 and 32A - CEGB approval No EPA208 63A - CEGB approval No EPA177 125A - CEGB approval No EPA233 R.C.C.B is 30mA sensitivity

Interlock Switch Sockets

Fused
Standard without RCCB IP65 12165-6 12325-6 12326-6 12635-6 12636-6 12096-6 With RCCB IP65 13165-6 13325-6 13326-6 13635-6 13636-6 13096-6

Solid Links
With RCCB & earth monitor IP65 15326-6 15635-6 15636-6 15095-6 15096-6 With RCCB IP65 14165-6 14325-6 14326-6 14635-6 14636-6 14096-6

Amps 16 32 (Pilot) 63 (Pilot) 125 (Pilot)

Poles 3P+N+E 3P+N+E 3P+N+P+E 3P+E 3P+N+E 3P+E 3P+N+P+E

Volts 415 415 415 415 415 415 415

h. 6 6 6 6 6 6 6

INTERLOCK SWITCH SOCKETS METAL HOUSINGS REFERENCE STANDARD:

Interlocks to Industrial Specification

EN 60309-2 BS EN 60309-2, CEE 17 - (BS 4343)

Amps 16

Poles 2P+E 3P+E 3P+N+E 2P+E 3P+E 3P+N+E 3P+N+P+E 2P+E 3P+E 3P+N+E 3P+N+P+E

32

(Pilot) 63 (Pilot) 125 (Pilot)

Volts 110 240 415 415 110 240 415 415 415 110 240 415 415 415

h. 4 6 6 6 4 6 6 6 6 4 6 6 6 6

Standard without RCCB IP44 SISR134-4 SISR134-6 SISR144-6 SISR154-6 SISR234-4 SISR234-6 SISR144-6 SISR254-6

With RCCB IP44 SIRR134-4 SIRR134-6 SIRR144-6 SIRR154-6 SIRR234-4 SIRR234-6 SIRR244-6 SIRR254-6 SIRR255-6

Standard without RCCB IP65 SISR135-6

With RCCB IP65

SIRR255-6 SISR435-4 SISR435-6 SISR445-6 SISR455-6 SISR855-6 SIRR435-4 SIRR435-6 SIRR445-6 SIRR455-6

Splashproof units to IP44 give protection against solid bodies larger than 1mm and projections of water from all directions. These devices are suitable for most indoor uses and non-continuous outdoor use. Where dust and moisture are normally present devices to IP65 should be selected. Watertight units to IP65 give protection against dust and the effect of jets of water. Pilot pins are standard on 63 and 125 Ampere devices.

14

Heavy Duty

INDUSTRIAL CONNECTORS

A-BELCO

DESCRIPTION
The Heavy Duty Range covers applications for current ratings from 30 to 150 Amps. All fittings are constructed with brass casings enabling applications under the most arduous working conditions where standard industrial fittings cannot meet the physical requirements.

HEAVY DUTY
The Heavy Duty range consists of plugs connectors and interlocked sockets from 30-150 amps.

FEATURES
The brass casings ensure that they can withstand arduous conditions where standard fittings could not operate. The 100A outlet and connector feature a locking arrangement to prevent accidental withdrawal on load.

APPLICATION
The Heavy Duty range represent a total system of connections typically used in heavy Industry environments such as: Shipyards Cement works Quarries Foundries This range has been tried & tested in the harshest environments for over 80 years.

FUSE UNITS
Supplied only with 30 and 60 Ampere units, and incorporating Pullcap fuse assemblies.

INTERLOCKS
The switch cannot be closed whilst the plug is withdrawn. The plug cannot be removed whilst the switch is closed.

CABLE FACILITIES
60 Ampere HH units can be supplied complete with extension cable box. 150 Ampere units are fitted with a cable dividing box. (fused only) Glands are not provided.

ENCLOSURES
Units are supplied for indoor use. For outdoor installation we recommend the addition of an overall canopy. 2-Pole + Earth 3-Pole + Earth 3-Pole + Neutral + Earth

15

INDUSTRIAL CONNECTORS

A-BELCO

Heavy Duty - Plugs, Sockets, Inlets, Connectors And Interlocks

PLUGS, SOCKETS, INLETS, CONNECTORS AND INTERLOCKS


Plugs Sockets & Inlets Connectors

Sockets
Amps 100 Poles 2P+E 3P+E 3P+P+E Volts 660 660 660 For flexible cables 9350 9355 9390 For pliable armoured cables 9352 9357 9392 Flanged base (square) 9370 9375 9410

Inlets
Flanged base (square) 9360 9365 9400 For flexible cables 9340 9345 9380 For pliable armoured cables 9342 9347 9382

Interlocks

Mating Plug or Connector

Socket
Amps 30 60 60 60 150 Poles 3P+E 2P+E 3P+E 3P+N+E 2P+E 3P+E 3P+N+E Volts 415 415 550 415 550 550 550 550 550 Unfused 10650

Inlet
Unfused 10220 10230

Socket
Fused 11003 11008 11013 Unfused 11000 11005 11010 11170* 11175* 11180

refer to Easigo 3457 5890 (connector) 3571 (plug) 5910 (connector) 3590 (plug) 3940 (plug) 9391 (plug)

* Accepts 100A plugs 9350 or 9355

16

Fuse Range

INDUSTRIAL CONNECTORS

A-BELCO

DESCRIPTION
The range consist of Fuse Bases, Cover plates, Fuse Carriers and Fuse Links suitable for Domestic and Industrial installations. The current ratings start at 2 amp through to 60amp for the Pullcap fuse assemblies and 5-600amp for the type 20 range.

PULLCAP FUSE ASSEMBLIES - Current ratings 2 -60 Amperes

Pullcap fuse assemblies for industrial and domestic use contain fuse links which are easily replaceable without the use of tools. Constructed with hardwearing phenolic mouldings, this versatile range features a selection of base cable terminations for varied requirements. The 30Ampere unit can be supplied with a DIN rail mounting which facilitates multiple fuse assemblies. Pullcap fuse assemblies contain fuse links to BS1361 and BS88, and are approved by Lloyds.

TYPE 20 FUSE LINKS - Current ratings 5 - 600 Amperes

Type 20 Fuse Links can be replaced without use of tools, and are suitable for existing Type 20 Fuse Carriers and Bases. The range consists of Fuse Bases, Cover Plates, Fuse Carriers and Fuse Links suitable for domestic and industrial installations.

5, 15 and 30AMP PULLCAP FUSE A SSEMBLIES

60AMP PULLCAP FUSE

Fuse Rating

E 22.2

F 4.8 6.3 7.9

5A

30.2 14.3 44.4 6.3 19

15A 34.9

48.4 10.3 25.4

30A 41.3 22.2 51.6 12.7 28.6

17

INDUSTRIAL CONNECTORS

A-BELCO

Fuse Range

FUSE LINKS

FUSE BASES - FC/FC Front-connections both ends

COVER PLATES

FUSE CARRIERS
BC/FC One back and one front connection BC/BC Two back connections

TYPE LA TO FIT CARRIER F194


CURRENT RATING 2A 5A Solid link PACK QTY. 10 10 10 CATALOGUE NUMBER F382 F190* SL-A

TYPE LD TO FIT CARRIER F196


CURRENT RATING 20A 31A Solid link PACK QTY. 10 10 10 CATALOGUE NUMBER F564 F192* SL-D

Complying with BS88 1952 (250A C4) and (*) also with BS1361 1947 (250 A C3) class Q1 fusing factor.

Complying with BS88 1952 (250A C4) and (*) also with BS1361 1947 (250 A C3) class Q1 fusing factor.

TYPE LC TO FIT CARRIER F195


CURRENT RATING 2A 5A 8A 10A 16A 20A Solid link PACK QTY. 10 10 10 10 10 10 10 CATALOGUE NUMBER F550 F551 F552 F562 F191* F937* SL-C

TYPE MD TO FIT CARRIER F271


CURRENT RATING 2A 4A 6A 8A 10A 16A 20A 25A 30A Solid link PACK QTY. 10 10 10 10 10 10 10 10 10 10 CATALOGUE NUMBER F313 F314 F316 F317 F318 F319 F320 F321 F322 SL-D

Complying with BS88 1952 (250A C4) and (*) also with BS1361 1947 (250 A C3) class Q1 fusing factor.

Asta certified to BS88 1975 for 80kA at 415V a.c. and 40kA at 250V d.c. Class Q1 F.F

TYPE LE TO FIT CARRIER F197


CURRENT RATING 5A 10A 15A 20A 30A 40A 50A 60A Solid link PACK QTY. 10 10 10 10 10 10 10 10 10 CATALOGUE NUMBER F523 F997 F524 F1000 F525 F998 F1001 F193 SL-E

FUSE BASES
TERMINAL CONNECTORS
FC/FC FCL/FCL FC/BBC

PACK QTY. Front-connections both ends Front-connections both endsDIN rail mounting Looping front-connections both ends One front & one busbar connection One back & one front connection Two back connections Front-connections both ends Looping front-connections both ends One front & one busbar connection One back & one front connection Two back connections 10 10 10 10 10 10 10 10 10 10 10

CATALOGUE NUMBER F246 F246D F456 F247 F274 F276 F198 F438 F261 F262 F264

30A FC/FC FC/FC FCL/FCL C/BBC BC/FC BC/BC 60A FC/FC FCL/FCL C/BBC BC/FC BC/BC

BC/FC

Complying with BS88 1967 category of duty 415 ac 46 class Q1 fusing factor.

BC/BC

18

Fuse Range

INDUSTRIAL CONNECTORS

A-BELCO

COVER PLATES
CURRENT RATING 30A 5A
30A

COLOUR

15A 30A

60A

60A

blank plate

PACK QTY. 10 10 10 10 10 10 10

CATALOGUE NUMBER F209 F266 F210 F377 F211 F268 F475 F214

FUSE CARRIERS
CURRENT RATING 5A 30A 15A
30A
60A

COLOUR

30A 60A

PACK QTY. 10 10 10 10 10 10 10

CATALOGUE NUMBER F194 F269 F195 F376 F196 F271 F197

Type 20 Cartridge Fuse Links


In order to give continuity of service to traditional users of Type 20 Fuse Assemblies, we have introduced a range of replacement fuse links (listed below). Overall dimensions are maintained to fit Type 20 carriers, but the barrels are shorter in length. Type 20 links are directly replaced by Pullcap type LE links. OBSOLETE CATALOGUE NO. GPE - 20E - 5A GPE - 20E - 10A GPE - 20E - 15A GPE - 20E - 20A GPE - 20E - 25A GPE - 20E - 30A GPE - 20E - 40A GPE - 20E - 50A GPE - 20E - 60A GPE - 20F - 15A GPE - 20F - 30A GPE - 20F - 40A GPE - 20F - 50A GPE - 20F - 60A GPF - 20F - 80A GPF - 20F - 100A * to fit carrier catalogue no. F197 REPLACEMENT CATALOGUE NO. F 523* F 997* F 524* F 1000* F 525* F 998* F 1001* F 193* RGPF - 20F - 16A RGPF - 20F - 32A RGPF - 20F - 40A RGPF - 20F - 50A RGPF - 20F - 63A RGPF - 20F - 80A RGPF - 20F - 100A OBSOLETE CATALOGUE NO. GPG - 20G - 125A GPG - 20G - 150A GPG - 20G - 200A GPG - 20H - 125A GPG - 20H - 150A GPG - 20H - 200A GPH - 20H - 250A GPH - 20H - 300A GPH - 20H - 350A GPH - 20H - 400A GPH - 20J - 250A GPH - 20J - 300A GPH - 20J - 350A GPH - 20J - 400A GPJ - 20J - 500A GPJ - 20J - 600A REPLACEMENT CATALOGUE NO. RGPG - 20G - 125A RGPG - 20G - 160A RGPG - 20G - 200A RGPH - 20H - 125A RGPH - 20H - 160A RGPH - 20H - 200A RGPH - 20H - 250A RGPH - 20H - 315A RGPH - 20H - 355A RGPH - 20H - 400A RGPJ - 20J - 250A RGPJ - 20J - 300A RGPJ - 20J - 355A RGPJ - 20J - 400A RGPJ - 20J - 500A RGPJ - 20J - 630A

19

INDUSTRIAL CONNECTORS

A-BELCO

Custom Build Combination Units

Custom Build Combination Units A-Belco Industrial Connectors offers flexibility in the design, manufacture and assembly of custom build products, with experienced electrical and mechanical engineers and established manufacturing, assembly and testing facilities on site. From the simplest unit to large, more complex assemblies including socket outlets, MCB, RCD or RCBO devices and control transformers, in metal or plastic enclosures. Multiple sockets and protective device combinations are also available.

Enclosure or Housing Aluminium Stainless Steel (316L, 304L) Mild Steel pre galvanised and painted Thermoplastic (ABS, GRP, Polycarbonate, Butyl rubber)

Lock Options Padlock Key-lock Lid-interlock

Mounting Options Wall mounting (surface or flush) Free standing pole-mount Portable

Design Options Socket outlets Integral transformer Indicator lamps Interlocked switch sockets (fused units available) Can be fitted with MCB / RCD / RCBO devices Fuse Switches On-load Isolators (AC23 compliant) Control transformers Earth monitoring units

Socket Options BS196: 5A, 15A, 30A, 60A IEC309: 16A, 32A, 63A, 125A BS1363: 13A

Incoming supply Voltages up to 690v AC 2P, 3P, 4P Frequency 50-500Hz

A-Belco custom build units serve a wide range of applications including adverse industrial, marine, chemical, power, industrial and rail.
20

Drawings - Easigo Range

INDUSTRIAL CONNECTORS

A-BELCO

Straight Plug

Description 5AMP

Max. Cable mm L&N CONTACTS EARTH CONTACTS 4 2.5

Max. Cable 11 11

Wt. Kg .12 .12

Description 15AMP 2POLE + E 3POLE + E

A 83 83

B 104 104

C 48 57

Max Cable mm Phase Earth 6 6

Max. Cable 12 13

Wt. Kg .25 .33

6 6
Max Cable mm Phase Earth 25 16

Description 60AMP ALL TYPES

A 200

B 74

C 148

Max. Cable 30

Wt. Kg 1.4

3 pole fused Plug

Description 15AMP 3POLE + E

A 137

B 58

Max Cable mm Earth Phase 6 6

Max. Cable 16

Wt. Kg .29

Angled Socket

Description 5AMP 15AMP 2POLE + E 2POLE + E 2POLE + PILOT + E 3POLE + E 3POLE + PILOT + E 30AMP 2POLE + E 2POLE + PILOT + E 3POLE + E 3POLE + PILOT + E

A 48 47 49 63 63 65

B 43 47 52 58 58 65

C 64 70 75 92 92 96

D 65 73 78 93 93 100

Max Cable mm Phase Earth 6 6 6 10 10 10 2.5 6 6 10 10 10

Max. Cable 11 12 13 18 18 18

Wt. Kg .10 .14 .17 .32 .32 .32

Surface Socket

Description 5AMP 15AMP 2POLE + E 2POLE + E 2POLE + PILOT + E 3POLE + E 3POLE + PILOT + E 30AMP 60AMP ALL TYPES ALL TYPES

A 27 38 42 56 56 82.5

B 57 68 76 84 84 108

C 3.5 4.5 4.5 4.5 4.5 7

D 51 60.5 68 76 76 95

E 25 36 44 50 50 60

F M3 M3.5 M3.5 M3.5 M3.5 M6

Max. Cable mm 6 10 10 10 25 25

Wt. Kg .12 .25 .30 .53 .53 .12

Flush (Circular flap) Socket

Description 15AMP 2POLE + PILOT + E 3POLE + E 3POLE + PILOT + E 30AMP 60AMP ALL TYPES ALL TYPES

C 68 85.5 85.5 80

D 5.5 5.5 5.5 5.8

E M5 M5 M5 M5

F 73 80 80 92

G 95 108 108 110

Max. Cable mm 10 10 25 25

Wt. Kg .5 .48 .88 .88 1.0

46 86 59 111 59 111 95 100

21

INDUSTRIAL CONNECTORS

A-BELCO

Drawings - Easigo Range

Flush (Square flap) Socket IP55

Description 5AMP 15AMP 2POLE + E 3POLE + E

A 27 40

B 76 86

C 57 68.3

D 4.5 5.5

E M3.5 M5

F 54 73

G 85 95

Max. Cable mm 6 10

Wt. Kg .17 .27

Straight Connector

Description 15AMP 30AMP 3POLE + PILOT + E 2POLE + E 2POLE + PILOT + E 3POLE + E 3POLE + PILOT + E

A 84 84 84

B 140 140 140

Max Cable mm Phase Earth 10 25 6 10

Max. Cable 18 18

Wt. Kg .85 .85

25

10

25

.85

Angled Connector

Description 5AMP 15AMP 2POLE + E 2POLE + E 2POLE + PILOT + E 3POLE + E

A 64 74 82

B 64 77 82

C 54 60 64

Max Cable mm Phase Earth 6 10 2.5

Max. Cable 11 12 13

Wt. Kg .17 .31 .36

Surface Appliance Inlet

Description 5AMP 15AMP 30AMP 2POLE + E 2POLE + E 3POLE + E 2POLE + E 3POLE + E

A 42 58 66 70 71.5

F 4BA M3 M4 4BA 4BA

G 29.5 35 48.5 48.5 48.5

Max Cable mm Phase Earth 6 6 10

Max. Cable 2.5 6 10

Wt. Kg .13 .25 .28 .34 .37

49 20 42 147.5 58 26 73 73 64 26 73 73 77 40 90 90 73 90 40 40

Flush mounted appliance inlet

Description 15AMP 2POLE + E

Max Cable mm Earth Phase 6 2.5

Max. Cable 2.5

Wt. Kg .42

34 86 68 5.5 M5 56 78

Surface mounted for conduit box surface sockets

CAT No 611 621 631 651

A 20 20 20 26

B 4 5.5 5.5 7

C 66.5 81 90.5 98.5

D M3 M3.5 M3.5 M3.5

E 51 60.5 68 76

F 57 68 76 84

G 33 33 41 44

H 17 17 21 24

Wt. Kg .14 .18 .30 .31

CAT No 661

A 127

B 95

C 67

D 33.5

E 57

F 32

Wt. Kg 3.9

22

Drawings - Easigo Range

INDUSTRIAL CONNECTORS

A-BELCO

Surface mounted conduit box for flush sockets and appliance inlets

CAT No 711 721 741

A 20 20 25

F 57 68 85.5

G 89 102 127

H 17.5 20.5 20.5

Wt. Kg .26 .44 .90

5.5 M3.5 76 33 7 M5 86 73 7 M5 111 80

Flush mounted conduit box for flush sockets and appliance inlets

CAT No 715 725 745

A 67 79 98

B 32 79 76

C 57 68 85.5

D 4BA 2BA 2BA

Wt. Kg .4 1.1 1.4

Multi-Socket outlets with Insulated housing

Description 5AMP 2POLE + E 2 GANG 3 GANG 2 GANG 3 GANG

E 7

H 40

Max Cable mm Phase Earth 10 10

Max. Cable 21

Wt. Kg 1.1 1.5 1.3 1.9

204 159 360 315 204 159 360 315

91 71

104 167 177

15AMP 2POLE + E

Multi-Socket outlets with Metal housing

Description

F G H

Max Cable mm Phase Earth 4

Wt. Kg 1.8 2.0

5AMP 2POLE + E 186 113 102 120.5 101.5 7 24 21 165 10 15AMP 2POLE + E 175

Interlock Switch Sockets 2 pole + earth 5 and 15 amperes

Description 5AMP 15AMP 2POLE + E 2POLE + E

D E 5 5 50.5 63.5

L M

Max Cable mm Phase Earth 6

Wt. Kg .95 1.2

76 121 60 86 137 68

73 14 67 76 17 75

21 14.5 21 16

5 24 6 6 24

All types except 2 pole + earth 5 and 15 amperes and R.C.D. units
D

Description 15AMP 30 AMP 60 amp

A 222 222 232

B 158 158 192

C 145 145 180

D 102 102 129

E 35 35 35

C E

23

INDUSTRIAL CONNECTORS

A-BELCO

Drawings - Easigo / Ceego Range

Interlocked switched sockets with R.C.D

Description 15AMP 30 AMP 60 amp

A 222 222 232

B 300 300 374

C 288 288 370

D 103 103 128

E 35 35 35

B D F
305

60 amp - Fuse Switch Socket with Rccb to CEGB Specification


Description 60A All types A 560 B 326 C 205 D 296 E 440 F 60 G 75 H 2 J 155 Max Cable Phase 35mm Earth Stud M8 Wt. Kg 23

AE
305

10

Ceego Plugs and Sockets


Sockets square flange (16A AND 32A)
Description 16A 2P+E (RS) 2P+E (A) 2P+E (L) 3P+E (L) 2P+E 3P+E A 52 30 30 30 B 20 34 34 41.3 C 75 67 85.7 85.7 D 115 90 90 128 D E 95 72 72 78 104 95 95 97 F 62 60.3 85.7 85.7 G 47 47.6 68 68 H 56 53.9 53.9 60.3 76.2 J 5.1 4.7 5.5 5.5 5.5 Max cable mm 6 Wt Kg 0.14 0.16 0.18 0.20 0.27 0.28

32A

30 42.8 85.7 150 95 125 85.7 68

16

Sockets

32A with Pilot

Plugs

32A with Pilot

Socket square flange (63A)

Insulated housing

Amps 16

No. of poles 2P + E

No. of Sockets 2

A 151

Max Cable mm Wt. Kg 10 0.82

106 21

24

Drawings - Ceego Range

INDUSTRIAL CONNECTORS

A-BELCO

Multi-gang sockets

Amps 16

No. of Pins 2P + E

No. of Sockets 2 3 4

A 151 360

B 106 315

Max Cable mm 21 10

Wt. Kg 0.82 1.30 1.60

Angle Entry Plugs

Description 16A 32A 2P+E 3P+E 2P+E 3P+E

A 90 90 120

B 85 90 110

C 43.5 49.5 57.3

Max Cable mm 13 18 6 10

Wt. Kg 0.11 0.12 0.18 0.19

Ceego Sockets to Industrial Specifications


16&32A metal box without RCCB
Description 16 AMP 2POLE + E 3POLE + E 4POLE + E 2POLE + E 3POLE + E 4POLE + E A 50 Splashproof B 48 50 55 58 60 Watertight B 55 57.5 60 62 69

32 AMP

50

63A metal box with RCCB

Description 63 AMP 2POLE + E 3POLE + E 4POLE + E

A 50

Splashproof B 67.5

Watertight B 80

63A metal box without RCCB

Description 63 AMP 2POLE + E 3POLE + E 4POLE + E

A 50

Splashproof B 67.5

Watertight B 80

16&32A metal box with RCCB

Description 16 AMP 2POLE + E 3POLE + E 4POLE + E 2POLE + E 3POLE + E 4POLE + E

A 50

Splashproof B 48 50 55 58 60

Watertight B 55 57.5 60 62 69

32 AMP

50

25

INDUSTRIAL CONNECTORS

A-BELCO

Drawings - Heavy Duty Range

Ceego Sockets to Power Station CEGB Specification


16 & 32A
32A Max. Cable Size = 35mm 16A Max. Cable Size = 35mm Weight = 10kg

63&125A
Description 63A 125A A B C D E F G H I

Max Cable mm Phase

Earth Stud Wt. KG 1048 997 1048 997

All types 560 326 205 296 440 60 75 2 170 35mm All types 730 455 214 425 610 60 75 2 260 70mm

Heavy Duty - Plugs, Sockets, Connectors


60 Amp connector
Max. Cable mm Phase contacts Earth contacts 25 25 Max. Cable 41 Weight kg 2.6

60 Amp interlock inlet

Max. Cable mm

Weight kg

60 Amp interlock socket

Max. Cable mm

Weight kg

Phase contacts 70 7.9 Earth contacts 16

Phase contacts 25 20 Neutral contacts Earth contacts 16

60 Amp interlock fuse socket

Max. Cable mm Phase contacts Neutral contacts Earth contacts


8

Weight kg 70 23 35

26

Drawings - Heavy Duty Range

INDUSTRIAL CONNECTORS

A-BELCO

100 Amp plug

Cable description Armoured (pliable) Flexible

A 380 305

Max Cable mm Phase Earth Pilot 95 70 50

Max Cable 55

Wt. Kg 9 6.9

100 Amp socket

Max. Cable mm Phase contacts Pilot contacts Earth via flange fixing 95 50

Weight kg 4.5

100 Amp connector

Cable description Armoured (pliable) Flexible

A 330 255

B 385 310

Max Cable mm Phase Earth Pilot 95 70 50

Max Cable 55

Wt. Kg 10.2 8.1

100 Amp inlet

Max. Cable mm Phase contacts Pilot contacts 95 50

Weight kg 3.2

150 Amp interlock socket

Cable description With Neutral Link Without Neutral Link

A 1048 997

Max Cable mm Phase Earth Pilot 70 35 50

27

INDUSTRIAL CONNECTORS

A-BELCO

Index

Cat.No. EASIGO Series 611 621 631 651 661 711 715 721 725 741 745 1000 1005 1010 1020 1030 1034 1055 1060 1110 1110AN 1110DR 1110XK 1120 1120AN 1120DR 1120XK 1210 1210AN 1210DR 1210XK 1220 1220AN 1220DR 1220XK 1310 1310AN 1310DR 1310XK 1320 1320AN 1320DR 1320XK 1410 1410AN 1410DR 1410XK 1420 1420AN 1420DR 1420XK 1515 1515AN 1515DR 1515XK 1525 1525AN 1525DR 1525XK 1615 1615AN 1615DR 1615XK 1625 1625AN 1625DR

Page

p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8

1625XK 1715 1715AN 1715DR 1715XK 1765 1765AN 1765DR 1765XK 1830 1830AN 1830DR 1830XK 1880 1880AN 1880DR 1880XK 1930 1930AN 1930DR 1930XK 1980 1980AN 1980DR 1980XK 2000 2000AN 2000DR 2000F 2000FAN 2000FDR 2000FXK 2000XK 2004 2004AN 2004DR 2004XK 2015 2015AN 2015DR 2015XK 2050 2050AN 2050DR 2050F 2050FAN 2050FDR 2050FXK 2050XK 2065 2065AN 2065DR 2065XK 2070 2070AN 2070DR 2070XK 2100 2100AN 2100DR 2100F 2100FAN 2100FDR 2100FXK 2100XK 2115 2115AN 2115DR 2115XK 2150

p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.5 p.5 p.5 p.5 p.8 p.8 p.8 p.8 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.8 p.8 p.8 p.8 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6

2150AN 2150DR 2150XK 2165 2165AN 2165DR 2165XK 2200 2200AN 2200DR 2200XK 2215 2215AN 2215DR 2215XK 2250 2250AN 2250DR 2250XK 2250F 2250FAN 2250FDR 2250FXK 2265 2265AN 2265DR 2265XK 2300 2300AN 2300DR 2300XK 2315 2315AN 2315DR 2315XK 2350 2350AN 2350DR 2350XK 2365 2365AN 2365DR 2365XK 2400 2400AN 2400DR 2400XK 2415 2415AN 2415DR 2415XK 2500 2550 2600 2650 2650/P 3017 3017AN 3017DR 3017XK 3082 3082AN 3082DR 3082XK 3092 3092AN 3092DR 3092XK 3162 3221

p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.9 p.5

3221AN 3221DR 3221XK 3227 3227AN 3227DR 3227XK 3290 3290AN 3290DR 3290XK 3295 3295AN 3295DR 3295XK 3302 3302AN 3302DR 3302XK 3307 3307AN 3307DR 3307XK 3352 3353 3402 3402AN 3402DR 3402XK 3407 3407AN 3407DR 3407XK 3413 3423 3452 3452AN 3452DR 3452XK 3457 3457AN 3457DR 3457XK 3565 3570 3571 3585 3590 3590 3600 3600AN 3600DR 3600XK 3603 3603AN 3603DR 3603XK 3650 3650AN 3650DR 3650XK 3680 3680AN 3680DR 3680XK 3700 3700AN 3700DR 3700XK 3730

p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.9 p.9 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.9 p.9 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.8 p.5 p.5 p.8 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5

3730AN 3730DR 3730XK 3750 3750AN 3750DR 3750XK 3780 3780AN 3780DR 3780XK 3905 3910 3910 3925 3925/P 3930 3930 3940 3940 6010 6010AN 6010DR 6010XK 6042 6042AN 6042DR 6042XK 6050 6050AN 6050DR 6050XK 6070 6070AN 6070DR 6070XK 6100 6100AN 6100DR 6100XK 6105 6105AN 6105DR 6105XK 6130 6130AN 6130DR 6130XK 6135 6135AN 6135DR 6135XK 6140 6140AN 6140DR 6140XK 6145 6145AN 6145DR 6145XK 6160 6160AN 6160DR 6160XK 6165 6165AN 6165DR 6165XK 6200 6200AN

p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.8 p.5 p.5 p.5 p.8 p.5 p.8 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.5 p.5

6200DR 6200XK 6205 6205AN 6205DR 6205XK 6230 6230AN 6230DR 6230XK 6235 6235AN 6235DR 6235XK 6240 6240AN 6240DR 6240XK 6245 6245AN 6245DR 6245XK 6260 6260AN 6260DR 6260XK 6265 6265AN 6265DR 6265XK 6530 6530AN 6530DR 6530XK 6530F 6530FAN 6530FDR 6530FXK 6540 6540AN 6540DR 6540XK 6540F 6540FAN 6540FDR 6540FXK 6550 6550AN 6550DR 6550XK 6550F 6550FAN 6550FDR 6550FXK 6630 6630AN 6630DR 6630XK 6690 6690AN 6690DR 6690XK 6740 6740AN 6740DR 6740XK 6790 6790AN 6790DR 6790XK

p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.5 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.10 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6 p.6

28

Index

INDUSTRIAL CONNECTORS

A-BELCO

7200 7200AN 7200DR 7200XK 7204 7204AN 7204DR 7204XK 7210 7210AN 7210DR 7210XK 7220 7220AN 7220DR 7220XK 7230 7230AN 7230DR 7230XK 7240 7240AN 7240DR 7240XK 7250 7250AN 7250DR 7250XK 7260 7260AN 7260DR 7260XK 7270 7270AN 7270DR 7270XK 7280 7280AN 7280DR 7280XK 10505 10505AN 10505DR 10505XK 10505F 10505FAN 10505FDR 10505FXK 10515 10515AN 10515DR 10515XK 10515F 10515FAN 10515FDR 10515FXK 10555 10555AN 10555DR 10555XK 10555F 10555FAN 10555FDR 10555FXK 10565 10565AN 10565DR 10565XK 10565F 10565FAN

p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7

10565FDR 10565FXK 10574 10574AN 10574DR 10574XK 10575 10575AN 10575DR 10575XK 10575F 10575FAN 10575FDR 10575FXK 10576 10576AN 10576DR 10576XK 10577 10577AN 10577DR 10577XK 10577F 10577FAN 10577FDR 10577FXK 10585 10585AN 10585DR 10585XK 10585F 10585FAN 10585FDR 10585FXK 10586AN 10586DR 10600 10600AN 10600DR 10600XK 10602 10602AN 10602DR 10602XK 10610 10610DR 10610XK 10615DR 10620 10620DR 10620XK 10622 10622DR 10622XK 10630 10630AN 10630DR 10630XK 10640 10640AN 10640DR 10640XK 10642 10642AN 10642DR 10642XK 10650 10650DR 10650XK 10660

p.7 p.7 p.8 p.8 p.8 p.8 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.8 p.8 p.8 p.8 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7

10660DR 10660XK 10662 10662DR 10662XK 10670 10675 10680 10685 10685/P 12604* 13604* 13605CN* 13605DX* 15604DX* F313 F316 F318 F319 MSS0522 MSS0522AN MSS0522DR MSS0522XK MSS0522F MSS0522FAN MSS0522FDR MSS0522FXK MSS0523 MSS0523AN MSS0523DR MSS0523XK MSS1522 MSS1522AN MSS1522DR MSS1522XK MSS1522F MSS1522FAN MSS1522FDR MSS1522FXK MSS1523 MSS1523AN MSS1523DR MSS1523XK RES1151 RES1151DR RES1152 RES1152DR RES1153 RES1153DR RES1154 RES1154DR RES1301 RES1301DR RES1302 RES1302DR RES1303 RES1303DR RES1304 RES1304DR RES1600 RES1601 RES1602 RES1603 RES1604 RES1605 CEEGO Series 6640-4 6640-6

p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.7 p.10 p.10 p.10 p.10 p.10 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.9 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8 p.8

p.13 p.13

6640W-4 6640W-6 12096-6* 12165-6* 12325.6* 12326-6* 12635-6* 12636-6* 13096-6* 13165-6* 13325-6* 13326-6* 13635.6* 13636-6* 14096-6* 14165-6* 14325-6* 14326-6* 14635-6* 14636-6* 15095-6* 15096-6* 15326-6* 15635.6* 15636-6* A1-4h A1-6h FRP101-4 FRP101-6 FRP51-4 FRP51-6 MSA1632-4h MSA1632-6h MSA1633-4h MSA1633-6h MSA1634-4h MSA1634-6h MSS1632-4h MSS1632-6h MSS1633-4h MSS1633-6h MSS1634-4h MSS1634-6h P1-4h P1-6h P3-4h P3-6h P21-4h P21-6h P23-4h P23-6h P42-6h P44-6h P46-6h RP1-4h RP1-6h RP36-6h RS1-4h RS1-6h RS36-6h S1-4h S1-6h S3-4h S3-6h S21-4h S21-6h S23-4h S23-6h S42-6h S44.6h

p.13 p.13 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.12 p.12 p.12 p.12 p.12 p.12 p.13 p.13 p.13 p.13 p.13 p.13 p.13 p.13 p.13 p.13 p.13 p.13 p.12 p.12 p.12 p.12 p.12 p.12 p.12 p.12 p.13 p.13 p.13 p.12 p.12 p.13 p.12 p.12 p.13 p.12 p.12 p.12 p.12 p.12 p.12 p.12 p.12 p.13 p.13

S46-6h SIRR134-4 SIRR134-6 SIRR144-6 SIRR154-6 SIRR234-4 SIRR234-6 SIRR244-6 SIRR254-6 SIRR255-6 SIRR435-4 SIRR435-6 SIRR445-6 SIRR455-6 SISR134-4 SISR134-6 SISR135-6 SISR144-6 SISR154-6 SISR234-4 SISR234-6 SISR244-6 SISR254-6 SISR435-4 SISR435-6 SISR445-6 SISR455-6 SISR855-6 HEAVY DUTY 3571 3590 3940 5890 5910 9340 9342 9345 9347 9350 9350 9352 9355 9357 9360 9365 9370 9375 9380 9382 9390 9391 9392 9400 9410 10220 10230 10650 11000 11003 11005 11008 11010 11013 11170 11175 11180

p.13 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14 p.14

FUSE RANGE F190 F191 F192 F193 F194 F195 F196 F197 F198 F209 F210 F211 F214 F246 F247 F261 F262 F264 F266 F268 F269 F271 F274 F276 F313 F314 F315 F316 F317 F318 F319 F320 F321 F322 F376 F377 F382 F438 F456 F475 F523 F524 F525 F550 F551 F552 F562 F564 F937 F997 F998 F1000 F1001 SL-A SL-C SL-D SL-D SL-E p.18 p.18 p.18 p.18 p.19 p.19 p.19 p.19 p.18 p.19 p.19 p.19 p.19 p.18 p.18 p.18 p.18 p.18 p.19 p.19 p.19 p.19 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.19 p.19 p.18 p.18 p.18 p.19 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18 p.18

p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16 p.16

* CEGB approved

29

INDUSTRIAL CONNECTORS

A-BELCO

A-Belco Industrial Connectors Jubilee Industrial Estate Ashington Northumberland NE63 8UG UK

T: +44 (0) 1670 813275 F: +44 (0) 1670 851141

CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS

11KV 33KV CABLE JOINTS & CABLE TERMINATIONS FURSE EARTHING

connectors@a-belco.co.uk www.a-belco.co.uk

www.cablejoints.co.uk Thorne and Derrick UK Tel 0044 191 490 1547 Fax 0044 191 477 5371 Tel 0044 117 977 4647 Fax 0044 117 9775582

The A-Belco Industrial Connectors Range was formerly produced by Reyrolle and is constructed to the same standards and specifications today.