You are on page 1of 20

Three Phase Circuits

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

Three Phase Circuits


Chapter Objectives:
Be familiar with different three-phase configurations and how

to analyze them. Know the difference between balanced and unbalanced circuits Learn about power in a balanced three-phase system Know how to analyze unbalanced three-phase systems Be able to use PSpice to analyze three-phase circuits Apply what is learnt to three-phase measurement and residential wiring

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

Three phase Circuits


An AC generator designed to develop a single sinusoidal voltage for each rotation of the shaft (rotor) is referred to as a single-phase AC generator. If the number of coils on the rotor is increased in a specified manner, the result is a Polyphase AC generator, which develops more than one AC phase voltage per rotation of the rotor In general, three-phase systems are preferred over single-phase systems for the transmission of power for many reasons.
1. Thinner conductors can be used to transmit the same kVA at the same voltage, which reduces the amount of copper required (typically about 25% less). 2. The lighter lines are easier to install, and the supporting structures can be less massive and farther apart. 3. Three-phase equipment and motors have preferred running and starting characteristics compared to single-phase systems because of a more even flow of power to the transducer than can be delivered with a single-phase supply. 4. In general, most larger motors are three phase because they are essentially selfstarting and do not require a special design or additional starting circuitry.
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
3

Single Phase, Three phase Circuits

a) Single phase systems two-wire type

b) Single phase systems three-wire type. Allows connection to both 120 V and 240 V.

Two-phase three-wire system. The AC sources operate at different phases. ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu

Three-phase Generator
The three-phase generator has three induction coils placed 120 apart on the stator. The three coils have an equal number of turns, the voltage induced across each coil will have the same peak value, shape and frequency.

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

Balanced Three-phase Voltages

Three-phase four-wire system

Neutral Wire

A Three-phase Generator Voltages having 120 phase difference

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

Balanced Three phase Voltages

Neutral Wire

a) Wye Connected Source

b) Delta Connected Source

Van = V p 0 Vbn = V p 120 Vcn = V p 240

Van = V p 0 Vbn = V p + 120 Vcn = V p + 240

ELEC 24409: a) abcTheory 2 Circuit or positive

sequence

b) acb or negative sequence Dr. Kalyana Veluvolu

Balanced Three phase Loads


A Balanced load has equal impedances on all the phases

a) Wye-connected load

b) Delta-connected load

Balanced Impedance Conversion: Conversion of Delta circuit to Wye or Wye to Delta. ZY = Z1 = Z 2 = Z 3 Z = Z a = Zb = Zc


Z = 3ZY
ELEC 24409: Circuit Theory 2

1 ZY = Z 3
Dr. Kalyana Veluvolu

Three phase Connections


Both the three phase source and the three phase load can be connected either Wye or DELTA. We have 4 possible connection types. Y-Y connection Y- connection - connection -Y connection Balanced connected load is more common. Y connected sources are more common.

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

Balanced Wye-wye Connection


A balanced Y-Y system, showing the source, line and load impedances.

Line Impedance Source Impedance Load Impedance

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

10

Balanced Wye-wye Connection


Line current In add up to zero. Neutral current is zero: In= -(Ia+ Ib+ Ic)= 0

Phase voltages are: Van, Vbn and Vcn. The three conductors connected from a to A, b to B and c to C are called LINES. The voltage from one line to another is called a LINE voltage Line voltages are: Vab, Vbc and Vca Magnitude of line voltages is 3 times the magnitude of phase voltages. VL= 3 Vp

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

11

Balanced Wye-wye Connection


Line current In add up to zero. Neutral current is zero: In= -(Ia+ Ib+ Ic)= 0

Magnitude of line voltages is 3 times the magnitude of phase voltages. VL= 3 Vp

Van = V p 0, Vbn = V p 120, Vcn = V p + 120 Vab = Van + Vnb = Van Vbn = 3V p 30 Vbc = Vbn Vcn = 3V p 90 Vca = Vcn Van = Van + Vbn = 3V p 210
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
12

Balanced Wye-wye Connection


Phasor diagram of phase and line voltages

VL = Vab = Vbc = Vca = 3 Van = 3 Vbn = 3 Vcn = 3V p V p = Van = Vbn = Vcn


ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
13

Single Phase Equivalent of Balanced Y-Y Connection


Balanced three phase circuits can be analyzed on per phase basis.. We look at one phase, say phase a and analyze the single phase equivalent circuit. Because the circuit is balanced, we can easily obtain other phase values using their phase relationships.

Ia =
ELEC 24409: Circuit Theory 2

Van ZY
14

Dr. Kalyana Veluvolu

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

15

Balanced Wye-delta Connection


Three phase sources are usually Wye connected and three phase loads are Delta connected.

There is no neutral connection for the Y- system.


VAB Z VBC Z VCA Z

I AB = I BC = I CA =
Line currents are obtained from the phase currents IAB, IBC and ICA

I a = I AB I CA = I AB 3 30 I b = I BC I AB = I BC 3 30 I c = I CA I BC = I CA 3 30
ELEC 24409: Circuit Theory 2

I L = I a = Ib = Ic I p = I AB = I BC = I CA I L = 3I p
16

Dr. Kalyana Veluvolu

Balanced Wye-delta Connection


Phasor diagram of phase and line currents

I L = I a = Ib = Ic I p = I AB = I BC = I CA I L = 3I p

Single phase equivalent circuit of the balanced Wye-delta connection

Z 3
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
17

Balanced Delta-delta Connection


Both the source and load are Delta connected and balanced.

I AB =

V V VAB , I BC = BC , I CA = CA Z Z Z

I a = I AB I CA , I b = I BC I AB , I c = I CA I BC
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
18

Balanced Delta-wye Connection

Transforming a Delta connected source to an equivalent Wye connection

Single phase equivalent of Delta Wye connection

Vp30

3
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
19

Power in a Balanced System


The total instantaneous power in a balanced three phase system is constant.
v AN = 2V p cos(t ) vBN = 2V p cos(t 120) vCN = 2V p cos(t + 120) ia = 2 I p cos(t ) ib = 2 I p cos(t 120) ib = 2 I p cos(t + 120) p = pa + pb + pc = v AN ia + vBN ib + vCN ic p = 2V p I p [ cos(t ) cos(t ) + cos(t 120) cos(t 120) + cos(t + 120) cos(t + 120)] 1 cos A cos B = [cos( A + B ) + cos( A B )] Using the identity and simplifying 2

p = 3V p I p cos
The instantenous power is not function of time. The total power behaves similar to DC power. This result is true whether the load is Y or connected. The average power per phase Pp = p . 3 Pp = p
ELEC 24409: Circuit Theory 2

= V p I p cos
Dr. Kalyana Veluvolu
20

Power in a Balanced System


The complex power per phase is Sp. The total complex power for all phases is S.

p = 3V p I p cos 1 p = V p I p cos 3 Sp = Pp + jQp = Vp I p Pp = Qp = 1 p = V p I p sin S p = Vp I p 3 Complex power for each phase

P = Pa + Pb + Pc = 3Pp = 3V p I p cos = 3VL I L cos Q = 3Q p = 3V p I p sin = 3VL I L sin S=3Sp = 3Vp I p = 3I p Z p = S = P + jQ = 3VL I L Vp , I p , VL and I L are all rms values, is the load impedance angle
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
21

3Vp 2 Zp

Total complex power

Power in a Balanced System


S=3Sp = 3Vp I p = 3I p Z p = S = P + jQ = 3VL I L Vp , I p ,VL and I L are all rms values, is the load impedance angle
Notice the values of Vp, VL, Ip, IL for different load connections.
2

3Vp 2 Z p

Toal complex power

VL = 3 V p

IL = I p

VL = V p

IL = 3 I p
Ip

Vp Ip VL VL Vp Ip
VL

Vp
Ip

Vp Vp Ip

VL

VL Ip VL Vp

ELEC 24409: Circuit TheoryY 2

connected load.

connected Dr. Kalyana Veluvolu

load.

22

Power in a Balanced System

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

23

Single versus Three phase systems


Three phase systems uses lesser amount of wire than single phase systems for the same line voltage VL and same power delivered.

a) Single phase system

b) Three phase system

Wire Material for Single phase 2( r 2l ) 2r 2 2 = = = (2) = 1.33 Wire Material for Three phase 3( r '2l ) 3r '2 3
If same power loss is tolerated in both system, three-phase system use only 75% of materials of a single-phase system
ELEC 24409: Circuit Theory 2 Dr. Kalyana Veluvolu
24

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

25

VL=840 V (Rms)

IL Capacitors for pf Correction

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

26

IL =
ELEC 24409: Circuit Theory 2

S 73650 = = 50.68A 3 VL 3 840 Correction


27

Dr. Kalyana Veluvolu Without Pf

Unbalanced Three Phase Systems


An unbalanced system is due to unbalanced voltage sources or unbalanced load. In a unbalanced system the neutral current is NOT zero.

Unbalanced three phase Y connected load.


Line currents DO NOT add up to zero. In= -(Ia+ Ib+ Ic) 0

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

28

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

29

Three Phase Power Measurement


Two-meter method for measuring three-phase power

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

30

Residential Wiring

Single phase three-wire residential wiring

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

31

Problem 12.10 Determine the current in the neutral line.

UNBALANCED LOAD NEUTRAL CURRENT IS NOT ZERO

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

32

Problem 12.12 Solve for the line currents in the Y- circuit. Take Z = 6045 .

SINGLE PHASE EQUIVALENT CIRCUIT

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

33

Problem 12.22 Find the line currents Ia, Ib, and Ic in the three-phase network below. Take Z = 12 - j15, ZY = 4 + j6 , and Zl = 2 .
ONE DELTA AND ONE Y CONNECTED LOAD IS CONNECTED TWO Loads are parallel if they are converted to same type. Delta connected load is converted to Y connection.

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

34

Problem 12.26 For the balanced circuit below, Vab = 1250 V. Find the line currents IaA, IbB, and IcC.
BALANCED Y CONNECTED LOAD.

Source voltage given is line to line, obtain the line to neutral voltage.

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

35

Problem 12.47

The following three parallel-connected three-phase loads are fed by a balanced three-

phase source. Load 1: 250 kVA, 0.8 pf lagging Load 2: 300 kVA, 0.95 pf leading Load 3: 450 kVA, unity pf If the line voltage is 13.8 kV, calculate the line current and the power factor of the source. Assume that the line impedance is zero.

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

36

Problem 12.81

A professional center is supplied by a balanced three-phase source. The center has four plants, each a balanced three-phase load as follows:

Load 1: 150 kVA at 0.8 pf leading Load 2: 100 kW at unity pf Load 3: 200 kVA at 0.6 pf lagging Load 4: 80 kW and 95 kVAR (inductive) If the line impedance is 0.02 + j0.05 per phase and the line voltage at the loads is 480 V, find the magnitude of the line voltage at the source.

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

37

Problem 12.84

The Figure displays a three-phase delta-connected motor load which is connected to a line voltage of 440 V and draws 4 kVA at a power factor of 72 percent lagging. In addition, a single 1.8 kVAR capacitor is connected between lines a and b, while a 800-W lighting load is connected between line c and neutral. Assuming the abc sequence and taking Van = Vp 0, find the magnitude and phase angle of currents Ia, Ib, Ic, and In. Total load is UNBALANCED. LINE CURRENTS Ia, Ib, Ic ARE NOT ERQUAL

Single phase, 800 W lighting load connected to phase C only. Pf for lighting loads is unity.

I L = I1 =

S 3 VL

ELEC 24409: Circuit Theory 2

Dr. Kalyana Veluvolu

38

440 V

I1 =

S = 5.249 ( + 30 ) 3 VL

ELEC 24409: Circuit Theory 2