You are on page 1of 4

JOB NAME PURCHASER ENGINEER SUBMITTED TO SUBMITTED BY

LOCATION ORDER NO.

FOR:

Reference DATE

Approval

Construction

UNIT DESIGNATION:

Schedule No.

MODEL NO.

PRODUCT DATA
COOLING PERFORMANCE
TOTAL CAPACITY SENSIBLE CAPACITY EVAPORATOR PRESSURE AT SATURATION EVAPORATOR TEMPERATURE AT SATURATION TOTAL SUPPLY AIR TEMP. OF AIR ENTERING EVAPORATOR COIL / F DB/WB F CFM PSIG MBH MBH

DIMENSIONS INCHES

HEATING PERFORMANCE
Refer to field-installed accessories on reverse side.

SUPPLY AIR BLOWER PERFORMANCE


TOTAL SUPPLY AIR TOTAL RESISTANCE EXTERNAL TO UNIT BLOWER SPEED POWER OUTPUT REQUIREMENT MOTOR RATING POWER INPUT REQUIREMENT IWG RPM BHP HP KW / / AMPS AWG CFM

ELECTRICAL DATA
POWER SUPPLY TOTAL UNIT AMPACITY MINIMUM WIRE SIZE (Copper Conductors) MAXIMUM FUSE SIZE DUAL ELEMENT AMPS
MODEL
LB180 LB240

A
89-1/2 100-1/8

B
85.0 95-5/8

C
26.0 33-1/4

D
29-1/2 36-5/8

E
59 73-1/4

F
1-7/16 2-1/2

G
15-7/8 18-7/8

H
12-7/16 16-1/2

J
15-13/16 15-13/16

K
16 21-7/8

L
16 18

M
20-3/4 22-9/16

UNIT WEIGHT
TOTAL OPERATING WEIGHT (Including field-installed accessories) LBS.

IN S T A L L A T IO N C O N . IG U R A T IO N

V E A R R A V E D IS

R T N G R T C H

IC A L E M E N T IC A L A R G E

V E A R R A H O R D IS

R T IC A N G E M IZ O N T C H A R G

E N T A L E

H O R A R R A H O R D IS

IZ O N T N G E M IZ O N T C H A R G

A L E N T A L E

SPLIT-SYSTEM EVAPORATOR BLOWERS 15 & 20 TON


MODEL LB180 & 240

036-22148-001-B-0502 Supersedes: 036-22148-001-A-1201

SUSPENSION MOUNTING (Horizontal Application)


55" D 43-3/4"

SUSPENSION POINT
E

W/ 3HP MOTOR* 142 132 152 162 132 127 847

5"

A
43-3/4"

B
3 B BLOWER SECTION C EVAP. COIL SECTION HEATING COIL HANGER RODS (FIELD SUPPLIED) SUSPENSION CHANNEL F

C D E F Total Weight *Motor location at suspension point F.

Four 3/8" 16 weld nuts are provided in the unit support angles for ceiling suspension. Knockouts are provided in panels for access to these weld nuts. Support rods must be supplied in the field.

FIELD-INSTALLED ACCESSORIES
SUPPLY AIR PLENUM (1SP0405) . . . . . . . . . . . . . . . RETURN AIR GRILLE (1RG0405) . . . . . . . . . . . . . . . BASE (1BS0405 or 1BS0406) . . . . . . . . . . . . . . . . . . (Vertical Application Only) ELECTRIC HEATER* . . . . . . . . . . . . . . . . . . . . . . . . . Model Number Capacity (@ Volts) . . . . . . . . . . . . . . . . . Power Input Requirement . . . . . . . . . . . . . . . . . . . . (Less Blower Motor)

MBH KW

ACCESSORY DIMENSIONS INCHES


MODEL 1BS0405 1BS0406 A 23 3/8 23 3/8 B 89 1/2 100 1/8 C 30 3/4 37 7/8

SUPPLY AIR PLENUM (LB180 only)

BASE ACCESSORY

RETURN AIR GRILLE (LB180 only)

SUSPENSION MOUNTING (Horizontal Application)


UNIT
S U S P E N S IO N C H A N N E L D "X " 5 " A E "Y " "Y " H A N G E R R O D S (. IE L D S U P P L IE D )

DIM. (In.) X 69-1/4 Y 49-1/6

ACCESSORY 1HH0403

(Tons) 20, 25, 30

SUSPENSION POINT A B
.

20 TON UNIT 200 175 200 175 175 200 1125

3 B

1 -1 /2 C E V A P . C O IL S E C T IO N

B L O W E R S E C T IO N

C D E F
H E A T IN G C O IL A C C E S S O R Y

Total Weight

FIELD-INSTALLED ACCESSORIES
HOT WATER COIL (1HW0405, 1HW0406) . . . . . . . . Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Entering Water Temperature . . . . . . . . . . . . . . . . . . Water Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . Entering Air Temperature . . . . . . . . . . . . . . . . . . . . Water Pressure Drop. . . . . . . . . . . . . . . . . . . . . . . . MBH F GPM F PSI -

ACCESSORY DIMENSIONS INCHES

HOT WATER COILS


Coil Model 1HW04501 1HW04511 1HW04522 1HW04052 1HW04062 1HW04072 A 36 52 60-3/4 89-1/2 100-1/8 103-1/8 B 21-7/8 25 32-1/4 30-3/4 37-7/8 45-1/4 C 5 5 6 6 6 6 Water Coil Dimensions D E F 1-11/16 2-3/4 3-3/8 1-11/16 2-3/8 3-3/8 2-1/8 3-5/16 3-13/16 2-1/8 3-3/8 3-13/16 2-1/8 3-3/8 3-13/16 2 3-3/8 3-15/16 G 6-1/4 5-7/8 6-9/16 6-11/16 6-11/16 6-7/16 H3 1 NPTE 1 NPTE 1-3/8 O. D. 1-3/8 O. D. 1-3/8 O. D. 1-5/8 O. D. J3 1 NPTE 1 NPTE 1-3/8 O. D. 1-3/8 O. D. 1-3/8 O. D. 1-5/8 O. D.

1 Installs over the return air opening of the unit in front of the filters on 5, 7-1/2 and 10 ton units. Refer to the respective unit installation instruction for Duct Flange Dimensions. 2 3

Installs between the evaporator section and the blower section on 15 through 50 ton units. All NPTE connections are brass. All O.D. connections are copper.

SUSPENSION MOUNTING (Horizontal Application)

STEAM COILS
Coil Model 1NF04501 1NF04511 1NF04522 1NF04532 1NF04542 1NF04072 A 36 52 60-3/4 89-1/2 100-1/8 103-1/8 B 21-7/8 25 32-1/4 30-3/4 37-7/8 45-1/4 C 5 5 6 6 6 6 Steam Coil Dimensions D E 2-1/2 2-5/8 2-1/2 2-5/8 3-5/16 4-1/8 3-7/16 3-15/16 3-7/16 4-5/16 2 3-1/16 F 10-5/8 13-5/8 18-1/8 14-15/16 18-5/16 21-5/8 G3 1-1/2 NPTE 1-1/2 NPTE 1-1/2 NPTE 1-1/2 NPTE 2 NPTE 2 NPTE H3 1-1/2 NPTE 1-1/2 NPTE 1-1/2 NPTE 1-1/2 NPTE 1-1/2 NPTE 1 NPTE

1 Installs over the return air opening of the unit in front of the filters on 5, 7-1/2 and 10 ton units. Refer to the respective unit installation instruction for Duct Flange Dimensions. 2

Installs between the evaporator section and the blower section on 15 through 50 ton units.

NOTES:

Subject to change without notice. Printed in U.S.A. Copyright 2002 by Unitary Products Group. ALL RIGHTS RESERVED Supersedes: 036-22148-001-A-1201 036-22148-001-B-0502