GENERATOR PARAMETERS
This appendix provides detailed parameters for a number of generators used in case studies in various chapters and Appendix C. It is noted that all the paratmeters listed in this appendix are referred to the stator side.
B.1
Table B-1. 2.3 MW, 690 V, 50 Hz squirrel cage induction generator (SCIG) parameters Generator Type
Rated Output Power Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Rated Slip Number of Pole Pairs Rated Mechanical Torque
1.0 pu (continued)
319
Power Conversion and Control of Wind Energy Systems. By B. Wu, Y. Lang, N. Zargari, and S. Kouro 2011 the Institute of Electrical and Electronics Engineers, Inc. Published 2011 by John Wiley & Sons, Inc.
320
Table B-1. Generator Type Rated Stator Flux Linkage Rated Rotor Flux Linkage Stator Winding Resistance, Rs Rotor Winding Resistance, Rr Stator Leakage Inductance, Lls Rotor Leakage Inductance, L,r Magnetizing Inductance, Lm Moment of Inertia, J Inertia Time Constant, H Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB
Note: H = J(a>m)2l(2SB)
Continued SCIG, 2.3 MW, 690 V, 50 Hz 1.2748 Wb(rms) 1.2096 Wb(rms) 1.102 mil 1.497 mil 0.06492 mH 0.06492 mH 2.13461 mH 1200 kgm 2 5.8078 sec 1.2681 Wb(rms) 0.1838 1 0.58513 mH 17316.17 MF 1.0053 pu 0.9539 pu 0.006 pu 0.008 pu 0.111 pu 0.111 pu 3.6481 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
Table B-2. 1.45 MW, 575 V, 50 Hz SCIG parameters Generator Type Rated Output Power Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Rated Slip Number of Pole Pairs Rated Mechanical Torque Rated Stator Flux Linkage Rated Rotor Flux Linkage Stator Winding Resistance, Rs Rotor Winding Resistance, Rr Stator Leakage Inductance, Lh Rotor Leakage Inductance, Llr Magnetizing Inductance, Lm Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB SCIG, 1.45 MW, 575 V, 50 Hz 1.45 MW 1.4707 MW 1.72 MVA 575 V (rms) 331.98V(rms) 1723 A (rms) 50 Hz 0.8439 1007.2 rpm -0.0072 3 13.944 kN-m 1.063 Wb (rms) 0.9757 Wb (rms) 1.354 mil 1.39 mil 0.1044 mH 0.0498 mH 1.77016 mH 1.0567 Wb (rms) 0.1922 il 0.61187 mH 16599.34 (j.F 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
1.0 pu 1.006 pu 0.9233 pu 0.007 pu 0.0072 pu 0.1706 pu 0.0814 pu 2.8931 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
321
Table B-3. 3 MW, 3000 V, 60 Hz SCIG parameters Generator Type Rated Output Power Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Rated Slip Number of Pole Pairs Rated Mechanical Torque Rated Stator Flux Linkage Rated Rotor Flux Linkage Stator Winding Resistance, Rs Rotor Winding Resistance, Rr Stator Leakage Inductance, Lls Rotor Leakage Inductance, Llr Magnetizing Inductance, Lm Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB SCIG, 3.0 MW, 3000 V, 60 Hz 3.0 MW 3.0402 MW 3.36 MVA 3000 V (rms) 1732.1 V(rms) 646.1 A (rms) 60 Hz 0.8934 1812 rpm -0.0067 2 16.022 kN-m 4.6199 Wb (rms) 4.3916 Wb (rms) 16.623 mil 18.152 mii 0.782 mH 0.782 mH 27.168 mH 4.5944 Wb (rms) 2.6786 O 7.105 mH 990.3 MF 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
1.0 pu 1.0056 pu 0.9559 pu 0.0062 pu 0.0068 pu 0.1101 pu 0.1101 pu 3.8237 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
Table B-4. 4 MW, 4000 V, 50 Hz SCIG parameters Generator Type Rated Output Power Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Rated Slip Number of Pole Pairs Rated Mechanical Torque Rated Stator Flux Linkage Rated Rotor Flux Linkage Stator Winding Resistance, Rs Rotor Winding Resistance, Rr SCIG, 4.0 MW, 4000 V, 50 Hz 4.0 MW 4.0606 MW 4.842 MVA 4000 V (rms) 2309.4 V (rms) 698.88 A (rms) 50 Hz 0.8261 1510.5 rpm -0.007 2 25.671 kN-m 7.3917 Wb (rms) 6.7114 Wb (rms) 22.104 mil 23.1515 mil 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
322
Table B-4. Generator Type Stator Leakage Inductance, Ls Rotor Leakage Inductance, Llr Magnetizing Inductance, Lm Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB
Continued SCIG, 4.0 MW, 4000 V, 50 Hz 1.698 mH 1.698 mH 33.597 mH 7.3511 Wb(rms) 3.3044 H 10.518 mH 963.29 u.F 0.1614pu 0.1614 pu 3.1942 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
1.0 pu 0.0084 pu 0.0083 pu 0.167 pu 0.1323 pu 5.419 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
Table B-6. 1 MW, 575 V, 60 Hz DFIG parameters Generator Type Rated Mechanical Power Rated Stator Line-to-line Voltage Rated Stator Phase Voltage Rated Rotor Phase Voltage DFIG, 1.0 MW, 575 V, 60 Hz 1.0 MW 575 V (rms) 331.98 V (rms) 67.97 V (rms) 1.0 pu 1.0 pu 0.2047 pu
323
1.0 pu 0.0111 pu 0.0108 pu 0.1487 pu 0.1366 pu 4.6978 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
1.0 pu 0.0086 pu 0.008 pu 2.2141 pu 1.9483 pu 9.6044 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
324
1.0 pu 0.0101 pu 0.0097 pu 0.0273 pu 0.0257 pu 3.0522 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
325
Table B-9. Generator Type Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB
Continued PMSG, 2.0 MW, 690 V, 9.75 Hz, nonsalient pole 6.5029 Wb 0.2124 3.4666 mH 76865.87 |JLF 1.0 pu 1.0 pu 1.0 pu 1.0 pu
Table B-10. 2.45 MW, 4000 V, 53.33 Hz nonsalient pole PMSG parameters Generator Type Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Number of Pole Pairs Rated Mechanical Torque Rated Rotor Flux Linkage Stator Winding Resistance, Rs -axis Synchronous Inductance, Ld /-axis Synchronous Inductance, Lq Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB PMSG, 2.45 MW, 4000 V, 53.33 Hz, nonsalient pole 2.4487 MW 3.419 MVA 4000 V (rms) 2309.4 V (rms) 490 A (rms) 53.33 Hz 0.7162 400 rpm 8 58.4585 kN-m 4.971 Wb(rms) 24.21 mfi 9.816 mH 9.816 mH 6.892 Wb (rms) 4.6797 il 13.966 mH 637.72 (JLF 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 0.7213 pu 0.00517 pu 0.7029 pu 0.7029 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu
Table B-11. 2 MW, 690 V, 11.25 Hz salient pole PMSG parameters Generator Type Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Number of Pole Pairs PMSG, 2.0 MW, 690 V, 11.25 Hz, salient pole 2.0093 MW 2.2408 MVA 690 V (rms) 398.4 V (rms) 1867.76 A (rms) 11.25 Hz 0.8967 22.5 rpm 30 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu 1.0 pu (continued)
326
Table B-12. 2.5 MW, 4000 V, 40 Hz salient pole PMSG parameters Generator Type
Rated Mechanical Power Rated Apparent Power Rated Line-to-line Voltage Rated Phase Voltage Rated Stator Current Rated Stator Frequency Rated Power Factor Rated Rotor Speed Number of Pole Pairs Rated Mechanical Torque Rated Rotor Flux Linkage Stator Winding Resistance, Rs -axis Synchronous Inductance, Ld ij-axis Synchronous Inductance, Lq Optimal Angle of Stator Current (with respect to (r-axis) Base Flux Linkage, AB Base Impedance, ZB Base Inductance, LB Base Capacitance, CB