Closed Loop Hall Current Sensor CYHCS-B8


This Hall Effect current sensor is based on the closed loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.

Product Characteristics
Excellent accuracy Very good linearity Small size and encapsulated Less power consumption Current overload capability

Applications
Photovoltaic equipment

General Purpose Inverters AC/DC Variable Speed Drivers Battery Supplied Applications Uninterruptible Power Supplies Switched Mode Power Supplies

Electrical Data/Input
Part number CYHCS-B8-05A CYHCS-B8-10A CYHCS-B8-15A CYHCS-B8-20A CYHCS-B8-25A CYHCS-B8-30A CYHCS-B8-50A Primary Rated Current Ir (A) 5 10 15 20 25 30 50 Measuring Range Ip(A) 15 30 45 60 75 90 150 Primary Conductor (mm) 0.6 0.8 1.0 1.0 1.4 1.6 2x 1.6x1.5 Turns ratio 5:2500 3:3000 2:3000 2:2500 1:2500 1:3000 1:3125 Internal measuring resistor ( ) 400 400 400 250 400 400 250

Rated Output Voltage: Supply Voltage Current Consumption (at Vout=0V) Isolation voltage (50/60Hz, 1min) Accuracy: Linearity: Electric Offset Voltage Thermal Drift of Offset Voltage, Response Time: Frequency Bandwidth:

4V0.5% 15V 5%, 12mA 5kV 0.5% <0.1% FS 20mV 0.5mV/C < 1s DC ~ 150kHz

General Data
Ambient Operating Temperature: Ambient Storage Temperature: -40C ~ +85C -40C~ +125C

Markt Schwabener Str. 8 D-85464 Finsing Germany

Tel.: +49 (0)8121 2574100 Fax: +49 (0)8121 2574101 Email: info@cy-sensors.com http://www.cy-sensors.com

Technologies GmbH & Co KG

PIN Definition
For Rated Current 10A 30A For Rated Current 50A

1 2 3 4 5 6 7 8

1 - 15V GND +I N W 2. 5 ( ) 2 3 +15V

1. V-

3. V+ 6 +I N 4. Output
7 -I N

1 2 3 4 5 6 7 8

1. V2. GND 5 +I N 3. 2 V+ 6 +I N 4. Output - I N 7 3 +15V


1 - 15V 8 4 O T Input + I N U 6.

4 O 6. Input- I N W U T 8 +( )

7. Input or 5. Input + 8. Input -

5. Input + 7. Input 8. Input -

Operating instructions
1. Connect the pins of power source, outputs respectively and correctly, never make wrong connection for DC current. 2. Temperature of the primary conductor should not exceed 100 C.

Custom Sensors with other input current and output voltage are available