You are on page 1of 27

Add Conductor

LT Bus
1000
1000 Mtr
-

1000
Mtr

1000
Mtr

Load -A

1000
Mtr
C

Load -B

1000
Mtr
D

Load -C

Load -D

1000
Mtr
E

Load -E

Load -F

Convert Your Distribution system in to single Line Diagaram and then Enter Following Detail
Sending End Voltage

11000

% VOLTAGE REGULAT

Volt

Load

Load Detail

Load -A
Load -B
Load -C
Load -D
Load -E
Load -F
Load -G
Load -H
Load -I
Load -J
Load -K
Load -L
Load -M
Load -N
Load -O
Load -P
Load -Q
Load -R
Load -S
Load -T
Load -U

XYZ

TOTAL % Voltage Regulation of Line

1Ph/
3Ph
3Ph

KW

P.F

20000

0.8

Distance (Mtr)
From-To
Meter
To
A
1000
A
To
B
B
To
C
C
To
D
D
To
E
E
To
F
F
To
G
G
To
H
H
To
I
I
To
J
J
To
K
K
To
L
L
To
M
M
To
N
N
To
O
O
To
P
P
To
Q
Q
To
R
R
To
S
S
To
T
T
To
U
1000

Conductor
ACSR

Jignesh.Parmar
www.electricalnotes.wordpress.com

Add Conductor Detail


1000
Mtr

1000
Mtr

1000
Mtr

Load -F

Load -G

1000
Mtr
I

Load -H

Load -I

1000
Mtr

1000
Mtr

Load -J

Load -K

VOLTAGE REGULATION
Conductor

Code

Size

ACSR

PANTHER

Al (30 /3.00 ),GI(7 /3.00 )

Load
Amp
1312
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Conductor No of Cond /
Amp
Phase
370.00
3

Voltage
Drop (V)
84

84

Reciving
Voltge
10916
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

%VR
0.77%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.77%

1000
Mtr

1000
Mtr
L

Load -L

%VR
0.77%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.77%

1000
Mtr
M

Load -M

1000
Mtr
N

Load -N

1000
Mtr
O

Load -O

1000
Mtr
P

Load -P

1000
Mtr
Q

Load -Q

Load -R

1000
Mtr

1000
Mtr
S

Load -R

Load -S

1000
Mtr
T

Load -T

Load -U

1Ph
3Ph

Conductor

CODE WORD

Aluminum Area Sq
mm
Nominal

MOLE
ROSE
SQUIRREL
WEASEL
RABBIT
RACOON
DOG
WOLF
PANTHER
ZEBRA
MOOSE
GOPHER
FERRET
MINK
HORSE
BEAVER
OTTER
CAT
LEOPARD
COYOTE
TIGER
LYNX
LION
BEAR
GOAT
SHEEP
DEER
FLK
CAMEL
SPARROW
FOX
GUINEA
LARK

10
18
20
30
50
80
100
150
200
420
520
16
25
40
42
45
50
55
80
80
80
110
140
160
185
225
260
300
300
20
22
49
125

Main Sheet

ACSR(Aluminum conductor with Steel Rainforce)

ACSR

Stranding and Wire Diameter


Total Sectional
Area (Sq mm)

Sectional
10.60
18.10
20.98
31.61
52.88
78.83
105.0
158.1
212.1
428.9
528.5
25.90
41.87
63.32
71.58
74.07
82.85
94.21
129.70
128.50
128.10
179.00
232.50
258.10
316.5
366.1
419.3
465.7
464.5
33.16
36.21
78.56
196.1

12.37
21.12
24.48
36.88
61.70
91.97
118.5
194.9
261.5
484.5
597.0
30.62
49.98
73.65
116.20
87.53
97.91
111.30
148.40
151.60
161.80
226.20
293.90
326.10
400
462.6
529.8
588.4
537.7
39.22
42.92
127.2
247.8

WEIGHT MASS

DIA (mm)

Overall
Dia.
(mm)
appro

Kg/Km

1.50
1.96
2.11
2.59
3.53
4.09
1.57
2.59
3.00
3.18
3.53
2.36
3
3.66
2.79
3.99
4.22
4.50
1.76
1.90
2.36
2.79
3.18
3.35
3.71
3.99
4.27
4.5
3.35
2.67
2.79
2.92
2.92

4.50
5.88
6.33
7.77
10.05
12.27
14.15
18.13
21.00
28.62
31.77
7.08
9
10.98
13.95
11.97
12.66
13.50
15.48
15.86
16.52
19.53
22.26
23.45
25.97
27.93
29.89
31.5
30.15
8.01
8.37
14.6
20.44

43
73
85
128
214
318
394
727
976
1621
1998
106
171
255
542
303
339
385
493
521
604
844
1097
1219
1492
1726
1977
2196
1804
135
149
590
922

Conductor (AL)

Conductor (ST)

NO.

DIA (mm)

NO

6
6
6
6
6
6
6
30
30
54
54
6
6
6
12
6
6
6
6
26
30
30
30
30
30
30
30
30
54
6
6
12
30

1.50
1.96
2.11
2.59
3.35
4.09
4.72
2.59
3.00
3.18
3.53
2.36
3.00
3.66
2.75
3.99
4.22
4.5
5.28
2.54
2.36
2.79
3.18
3.35
3.71
3.99
4.27
4.5
3.35
2.67
2.79
2.92
2.92

1
1
1
1
1
7
7
7
7
7
1
1
1
7
1
1
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

Total

Main Sheet

Conductor

WEIGHT MASS
AL.

ST.

Kg/Km

Kg/Km

Resistance at
20 degC
Ohms/Km
(MAX)

29
49.5
58
87
145
215
288.3
438
588.5
1182
1463
72
116
173
204
205
230
261
360
365
363
506
659
734
896
1036
1188
1320
1318
92
101
224
556

14
23.5
27
41
69
103
105.7
289
387.5
439
535
34
55
82
338
98
109
124
133
156
241
338
438
485
596
690
789
876
486
43
48
366
366

2.78
1.618
1.394
0.9289
0.5524
0.3712
0.2792
0.1871
0.139
0.06868
0.05595
1.098
0.6795
0.4565
0.3977
0.3841
0.3434
0.302
0.2193
0.2214
0.2221
0.1589
0.1223
0.1102
0.0898
0.0777
0.0678
0.0611
0.0612
0.8578
0.7857
0.362
0.1451

Reactance at
20 degC
Ohms/Km
(MAX)

Current Rating
(Amps)
67
104
76
95
135
180
205
305
370
635
763
85
115
165
268
176
185
195
275
260
265
335
405
430
542
592
639
679
677
139
147
244
410

Ultimate
Breaking Load
(KN)
3.97
6.74
7.61
11.12
18.25
26.91
32.41
67.34
89.67
130.32
159.60
952
1503
2207
6108
2613
2923
3324
4137
4638
5758
7950
10210
11310
13780
15910
18230
20240
14750
1208
1313
6664
8559

AAAC

Conductor (AL)
CODE WORD
NO.
Akron
Alton
Ames
Azusa
Anaheim
Amherst
Alliance
Butte
Canton
Cairo
Darien
Elgin
Flint
Greely

7
7
7
7
7
7
7
19
19
19
19
19
37
37

Conductor

AAAC (All Aluminum Alloy Conductor)

Conductor (AL)

Overall Dia.
(mm) appro

DIA (mm)
.198
.250
.316
.398
.447
.502
.563
.642
.721
.783
.858
.927
.991
1.108

.0240
.0382
.0608
.0968
.1221
.1537
.1939
.2456
.3098
.3655
.4394
.5124
.5818
.7282

Resistance at 20 Reactance at 20
degC Ohms/Km degC Ohms/Km
(MAX)
(MAX)
0.785
0.493
0.310
0.195
0.154
0.123
0.097
0.077
0.061
0.052
0.043
0.037
0.033
0.026

Current
Rating
(Amps)
107
143
191
256
296
342
395
460
532
590
663
729
790
908

AAC

AAC (All

Conductor (AL)
CODE WORD
NO.
Peachbell
Rose
Iris
Pansy
Poppy
Aster
Phlox
OxIiP
Sneezewort
Valerian
Daisy
Laurel
Peony
Tulip
Daffodil
Canna
Goldentuft
Cosmos
Syringa
Zinnia
Hyacinth
Dahlia
Mistletoe
Meadowsweet
Orchid
Heuchera
Verbena
Flag
Violet
Nasturtium
Petunia
Cattail
Arbutus
Lilac
Cockscomb
Snapdragon
Magnolia
Goldenrod
Hawkweed
Camellia
Bluebell
Larkspur
Marigold
Hawthorn
Narcissus
Columbine
Carnation
Gladiolus
Coreopsis
Jessamine
Cowslip
Sagebrush
Lupine
Bitterroot
Trilium

7
7
7
7
7
7
7
7
7
7
7
19
19
19
19
19
19
19
37
19
37
19
37
37
37
37
37
61
37
61
37
61
37
61
37
61
37
61
37
61
37
61
61
61
61
61
61
61
61
61
91
91
91
91
127

DIA (mm)
.0612
.0772
.0924
.1903
.1228
.1379
.1548
.1739
.1890
.1147
.1953
.1185
.1257
.1331
.1357
.1447
.1538
.1584
.1135
.1622
.1162
.1711
.1226
.1273
.1311
.1326
.1375
.1071
.1391
.1083
.1424
.1109
.1446
.1142
.1560
.1215
.1606
.1251
.1644
.1280
.1671
.1302
.1351
.1398
.1444
.1489
.1532
.1574
.1614
.1694
.1482
.1572
.1657
.1739
.1537

Bluebonnet

127

.1660

AAC (All Aluminum Conductor)

Overall Dia.
(mm) appro
.184
.232
.292
.328
.368
.414
.464
.522
.567
.574
.586
.593
.629
.666
.679
.724
.769
.793
.795
.811
.813
.856
.858
.891
.918
.928
.963
.964
.974
.975
.997
.998
1.026
1.028
1.092
1.094
1.124
1.126
1.150
1.152
1.170
1.172
1.216
1.258
1,300
1.340
1.379
1.417
1.454
1.525
1.630
1.729
1.823
1.913
1.996

Resistance at
Reactance at 20
20 degC
degC Ohms/Km
Ohms/Km
(MAX)
(MAX)
0.805
0.506
0.318
0.252
0.2
0.159
0.126
0.0999
0.0846
0.0846
0.0793
0.0793
0.0706
0.063
0.0605
0.0534
0.0472
0.0445
0.0445
0.0425
0.0425
0.0382
0.0382
0.0355
0.0335
0.0328
0.0305
0.0305
0.0299
0.0299
0.0286
0.0286
0.0271
0.027
0.0239
0.0239
0.0226
0.0226
0.0216
0.0216
0.021
0.021
0.0195
0.0183
0.0173
0.0163
0.0155
0.0147
0.0141
0.0129
0.0115
0.0105
0.00969
0.009
0.00384

Current
Rating
(Amps)
103
138
185
214
247
286
331
383
425
426
443
444
478
513
526
570
616
639
639
658
658
703
704
738
765
775
812
812
823
823
847
847
878
879
948
948
982
983
1010
1011
1031
1032
1079
1124
1169
1212
1253
1294
1333
1408
1518
1612
1706
1793
1874

2.158

0.00756

2024