Ver. 1.1
Contents
Technical data.... 3 Operation principle. 4 Main circuit.... 4 - 6 Troubleshooting diagram... 7 Main ciruit diagrams. 8 Block diagram... 9 Operational tests / measurings.............. 10 Measurings........ 10, 11 Main transformer T001 prim. voltage... 12 Main transformer T001 sec. voltage..... 13 Voltage after sec. rectifier................. 14 Auxiliary coil voltage.... 15 Fan M001 voltage.......... 16 Pole voltage in OCV......... 16 Measuring points in the flat cable..... 17 Gate control, upper IGBTs.... 18 Gate control, lower IGBTs.... 19 Aux. voltage in DC-link.... 20 Signal lamp H2 control / VRD ON... 20 Main circuit card Z001 connectors.... 21 Main circuit card Z001 layout.... 22 Control card A001 layout... 23 Structure..24, 25 IGBT-transistor testing............... 26 Sec. diode testing............... 26 Notes.............. 27
Technical data
Minarc 150 Minarc 150 VRD Minarc 151
Supply voltage, 1~ 50/60 Hz 230 V 15% 230 V 15% 110 V 15% Loadability 35% ED (MMA) 140 A (7,5 kVA) 140 A (7,5 kVA) 140 A (7,5 kVA) 100% ED (MMA) 100 A (5,1 kVA) 100 A (5,1 kVA) 100 A (5,1 kVA) 35% ED (TIG) 150 A (5,0 kVA) 150 A (5,0 kVA) 150 A (5,0 kVA) 100% ED (TIG) 110 A (3,3 kVA) 110 A (3,3 kVA) 110 A (3,3 kVA) Supply cable / fuses 2,5 mm S / 3,3 m 16 A 2,5 mm S / 3,3 m 16 A 6 mm S / 2,0 m 32 A Welding current range (MMA) 10 A / 20,5 V140 A / 25,6 V 10 A / 20,5 V140 A / 25,6 V 10 A / 20,5 V140 A / 25,6 V Suitable stick sizes 1,53,25 mm 1,53,25 mm 1,53,25 mm Welding power adj. Stepless Stepless Stepless OCV ~ + 85 V ~ + 30 V ~ + 85 V Idling power < 10W < 10W < 10W Efficiency 0,8 0,8 0,8 Power factor 0,60 (140 A / 25.5 V) 0,60 (140 A / 25.5 V) 0,60 (140 A / 25.5 V) Temperature class B (130C) / H (180C) B (130C) / H (180C) B (130C) / H (180C) Operation temperature range -20+40C -20+40C -20+40C Stock temperature range -40+60C -40+60C -40+60C Casing class IP 23C IP 23C IP 23C Norms IEC 60974-1, -10 IEC 60974-1, -10 IEC 60974-1 EN 50199 EN 50199 EN 50199 Dimensions Length 320 mm 320 mm 320 mm Width 123 mm 123 mm 123 mm Height 265 mm 265 mm 265 mm Weight 4,0 (4,6) kg 4,0 (4,6) kg 4,4 (5,2) kg
Operation principle
Minarc power sources aredual-Forward inverters, controlled by PWM technology. Switching components are IGBT transistors. The operation frequency is ~ 80 kHz. Below is a picture of the dual-forward inverter operation principle. VDC 105 V1 0,5
Max.
~ + 320 V
1/3
t 13s
V2
When IGBTs V1 and V2 are non-conductive no power is transferred. Power is altered by changing the transistors timing (PWM).
Main circuit
X11/12
V16 C13 R9 V4, V5, V6
V20
X1
R31
X13
V21 V7, V3 L2 L1 C2, C3, C4
R32
C15
C5
X3
+t
R30
+t
C10 R23
C9
V11
T001
X12
V1, V2 T2 V8, V9, V10
X5
K1
Main circuit
X11/7
R14 R17 R13 R8
X11/12
V16 C11
R9
X1
V6, V2 L1 L2 C2, C3
V3, V4, V5
X13
X2
R24
C16
X3
C10
C9
V10
T001
X12
V1, V11 C4, C5 T2 V7, V8, V9
L001
X4 X5
C21
R34
V28, V29
X7
R21 R20
X003
X6 U
T001 V26, V27
V25
R35
R37
V26
X8 X9 X004
X11/11
V19 R11 V30
C20
V24
V28
X11/14
V23 C16
V22
R33
X10 X21
C14 C17 C19 R27 R36
X11/15
V18
R29
R24
V22
R25
X5
C18
X22
Main circuit
C21 R34 V28, V29 L001
X7
R21 R20
X003
X6 U
T001 V26, V27
V25
R35
R37
V26
X8 X9 X004
X11/11
V19 R11 V30
C20
V24
V28
X11/14
V23 C16
V22
R33
X10 X21
C14 C17 C19 R27 R36
X11/15
V18
R29
R24
V22
R25
X5
C18
X22
General
This machine may be repaired only by authorized repair shops and persons! The visual check must be done first, to find possible damages; loose wires, breaks and signs of overheating.
Troubleshooting diagram
DISTURBANCE Power source doesnt start; OCV ~ 0 V; POSSIBLE CAUSE Cooling fan M001 REMEDY Disconnect the fan connector X20 and start the power source again. If the power source starts and the OCV is ok, change the fan. Check the secondary diodes condition and change if needed. See the changing of secondary diodes, page 26. Check the primary side power semiconductors. If the voltage over the PTC R30 is more than ~ 230 Vac then there is a short circuit in the primary circuit. Change the faulty power semiconductor. See the IGBT transistor testing on page 26. Change the control card A001. Check the relay operation.
The power source starts and the OCV rises up to ~85 V, after which the power source shuts down. Th epower source can not be loaded. The automatic fuses are blown during start up.
Minarc 151
8
Block diagram
A001 Controller (PWM) Gate buffer Set value circuit Voltage watch MMA ignition MMA dynamics Temperature control Supply voltage watch Auxiliary voltage watch TIG-locking TIG-scaling
Z001 Power stage EMI-filter DC-link charging Aux. voltages Voltage reserve circuit OCV controller Overvoltage protection
16
4
Z002 Relaycard
Minarc 151
Measuring point A. Main transformer T001 primary voltage Measuring point B. Main transformer T001 secondary voltage Measuring point C. Voltage after seconday rectifier Measuring point D. Aux. coil voltage Measuring point E. Fan M001 voltage Measuring point F. Pole voltage
10
A B C D E
Main transformer T001 primary Main transformer T001 secondary After the rectifier Main transformer auxiliary coil Fan M001
11
12
13
14
15
Idling
Min. load
Max. load
16
G H I J
X1/1 X1/2 X1/3 X1/4 X1/5 X1/6 X1/7 X1/8 X1/9 X1/10 X1/11 X1/12 X1/13 X1/14 X1/15 X1/16
GND Current info from primary GND Gate control, upper IGBTs Gate control, lower IGBTs GND Supply voltage watch Temperature watch (PTC:t) GND Auxiliary voltage (+2030 V) Signal lamp H2 control / VRD Auxiliary voltage from DC-link GND Auxiliary voltage +20 V OCV control (~ +85 V) GND
17
18
19
20
Main circuit card Z001 connectors (Minarc 150) X21 X15 X14 X16 X17 X18 X19 X20
X22 X9 X8
X13
X1 X3 X5
X1, X3 X5 X6, X8 X7 X9 X10 X11 X12, X13 X14, X15 X16, X17 X18, X19 X20/1, 2 X21 X22
Supply voltage Protective earth Main transformer T001 sec. Sec. Choke L001 (+) X004 (-) X003 (+) Connection, A001 Main transformer T001 primary Main transformer T001 auxiliary coil PTC RT101 PTC RZ101 Fan M001 X003 (+) X004 (-)
21
Smoothing capacitors
Secondary rectifier
X11
EMI
22
N1
Voltage regulator (+ 20 V)
X1 S1
MMA/TIG
N2
PWM-circuit
R26
Max. current adjustment
N3 Comparator R49
Current adjustment
R35
Min. current adjustment
H2
ON / VRD ON
H1
Overheat protection
N4
Comparator
23
Structure
Z001
A001
3 mm
T10 T15
T25
24
Structure
25
IGBT-transistor testing
Discrete-IGBTs (50 A, 600 V) can be tested with an IGBT tester. When changing damaged IGBTs, the whole series must be changed, plus the gate resistors (10)!! Discrete-IGBTs tightening torque to the heatsink is 0,61,2 Nm!
C2E1/1 B2/6
E2/2
C1/3
B1/4
IGBT-TESTER
TR 1
OFF ON
CONTROL
TR 2
26
Notes
27