You are on page 1of 2

Technical data

Generator set specifications


Model
Prime Power Rating kVA / kW
Current (Amps)
Power Factor
No. of Phases

Engine specifications

Make
Model
BHP
Cooling
Aspiration
No. of Cylinders
RPM
Bore (mm) x Stroke (mm)
Compression Ratio
Displacement (Ltrs.)
Fuel
Fuel Consumption (Ltr/hr) @ 75% Load
with Radiator & Fan
Governor
Starting System
Lube oil Specification
Lube oil Sump Capacity (Ltrs.)
Lube oil consumption (LPH)
Total Coolant Capacity (Ltrs.)
Exhaust Pipe Size (mm)
Battery Capacity / Rating

Alternator specifications

Make (Brand)
Enclosure
Voltage Regulation (Max.)
Class of Insulation
RPM / Frequency
Power Factor
No. of Phases
Frame Size
Voltage
Recommended Cable size sq. mm. x No. of Runs
(Allum. Armoured AYFY 3 1/2 Core)

CP 15 D5 P
15/12
21
0.8 (lag)
3 Phase/ 1 Phase

CP 20 D5 P
20/16
28
0.8 (lag)
3 Phase/ 1 Phase

CP 25 D5 P
25/20
35
0.8 (lag)
3 Phase/ 1 Phase

Cummins
X 1.7 G1
20
Water Cooled
Natural
2
1500
91.44 x 127
18.5:1
1.7
HSD
2.9

Cummins
X 2.5 G2
32
Water Cooled
Natural
3
1500
91.44 x 127
18.5:1
2.5
HSD
3.7

Cummins
X 2.5 G2
32
Water Cooled
Natural
3
1500
91.44 x 127
18.5:1
2.5
HSD
4.8

Mechanical
12 V Electrical
CF4 15W40
5
0.01
6
50
88 AH 12 V

Mechanical
12 V Electrical
CF4 15W40
6.5
0.01
7.5
50
88 AH 12 V

Mechanical
12 V Electrical
CF4 15W40
6.5
0.01
7.5
50
88 AH 12 V

Newage (Stamford)
IP 23
+/- 1%
H Class
1500 / 50 Hz
0.8 (lag)
3 Phase
1 Phase
BC 164 D
BC 184 F
415 V
230 V
6x1
35 x 1

Newage (Stamford)
IP 23
+/- 1%
H Class
1500 / 50 Hz
0.8 (lag)
3 Phase
1 Phase
BC 184 E
BC 184 G
415 V
230 V
10 x 1
50 x 1

Newage (Stamford)
IP 23
+/- 1%
H Class
1500 / 50 Hz
0.8 (lag)
3 Phase
1 Phase
BC 184 F
BC 184 J
415 V
230 V
16 x 1
70 x 1

Conformance standards

IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046

Rating definition

Prime power rating is applicable for supplying continuous


electric power (at variable load) in lieu of commercially
purchased power.
Prime power is available for an unlimited number of hours
per year in a variable load application.
10% overload is available for 1 hour in every 12 hours of
operation.

Our energy working for you.TM


www.cumminsindia.com

2006 Cummins Power Generation Specifications subject to change without notice


PGBU/CIL/001/X 15-25 kVA/Powerica/90Deg./October 2006/1000

Rating definition is as per ISO 3046 / BS 5514.


Fuel consumption data is based on diesel having specific
gravity of 0.85 and conforming to IS:1460
Oil consumption data is based on oil having specific gravity of
0.89 and meeting CH4 API categories
Fuel consumption tolerance is +5%

Typical enclosure dimensions*


Genset Model
CP 15 D5 P
CP 20 D5 P
CP 25 D5 P

Rating (kVA)
15 kVA
20 kVA
25 kVA

Length (mm)

Width (mm)

2200
2200
2200

900
900
900

Height (mm)
1375
1375
1375

Weight (kgs.) (Dry)


775
880
880

Std. Fuel Tank Capacity (Ltrs)


55
55
55

Typical diesel generator set dimensions


Genset Model
CP 15 D5 P
CP 20 D5 P
CP 25 D5 P

Rating (kVA)
15 kVA
20 kVA
25 kVA

Length (mm)
1200
1400
1400

Cummins India Limited

Power Generation Business Unit


35A/1/2, Erandawana,
Pune 411 038. India
Tel.: (91) 020-6602 7525 Fax: (91) 020-6602 8090

Cummins Power Generation Offices:


Location:

Bangalore:
Chandigarh:
Chennai:
Coimbatore:
Delhi:Telefax:
Hyderabad:
Jaipur:
Kolkota:
Lucknow:
Vadodara:

Tel:

080-23613831/23611958
0172-2622535/2663087
044-24416429/24423412
0422-2430197/2436947
011-41618357/58/59/60/61
040-55612932/27678891
0141-2370201/2370356
033-22478065/22472481
0522-2786718/2787704
0265-2330627

Fax:

080-23614552
0172-2663087
044-24911120
0422-2445904
040-27678892
0141-2363746
033-22473833
0522-2787880
0265-2340623

Authorised
Representative

Our energy working for you.TM


www.cumminsindia.com

2006 Cummins Power Generation Specifications subject to change without notice


Cummins and PowerCommand are registered trademarks of Cummins Inc.
*Dimensions of the enclosure are excluding the silencer
Information contained in this publication is typical only and does not form part of any
contractual commitment
PGBU/CIL/001/X 15-25 kVA/Powerica/90Deg./October 2006/1000

Width (mm)

Height (mm)

725
725
725

1200
1200
1200

Weight (kgs.) (Dry)

400
480
480

Powerica Limited

74 - A Mittal Court, Nariman Point


Mumbai - 400 021
Tel.: (022) 6656 2525 Fax: (022) 2204 3782
Email: dgsets@vsnl.com
Website: www.powericaltd.com

Powerica Ltd. - Regional and branch offices:


Location:

Ahmedabad
Aurangabad
Bangalore
Chennai
Cochin
Coimbatore
Faridabad
Goa
Hyderabad
Kolkata
Madurai
Nagpur
Nasik
Pune
Vijaywada

Tel:

(079) 2646 7591/ 2646 8550


(0240) 235 2232/ 232 5132
(080) 4123 5741/ 2
(044) 4214 4394-6
(0484) 235 3595/ 236 5906
(0422) 249 5125/ 249 8998
(0129) 227 5010/ 404 2177
(0832) 243 8587
(040) 2781 9906/ 2781 2861
(033) 3022 2231
(0452) 420 0081/ 42
(0712) 259 1062
(0253) 329 9349/ 257 6779
Mobile: (0) 9371194768
(020) 2546 0991/ 2546 5430
(0866) 257 0792

Fax:

(079) 2646 7591


(0240) 233 9785
(080) 2225 8649
(044) 2826 0281
(0484) 236 5906
(0422) 249 5125
(0129) 227 5416
(0832) 243 8587
(040) 2781 2210
(033) 2287 0331
(0452) 420 0081/ 42
(0712) 259 1035
(0253) 257 6779
(020) 2546 0991
(0866) 662 2751