Professional Documents
Culture Documents
PLFY-P NBMU-E
THE NEW 4-WAY CASSETTE NBMU OFFERS 72 DIFFERENT AIRFLOW PATTERNS, MAKING IT IDEAL FOR APPLICATIONS WITH CEILINGS UP TO 13 -13/16 FT (4.2 m) IN HEIGHT.
PLFY-P NCMU-E
Compact body to match with 2 feet (600 mm) x 2 feet (600 mm) ceiling design (NCMU)
Auto-fan-speed mode enables speedy and comfortable heating during heating startup.
The Auto-fan-speed mode is added to the usual four steps Low, Mid1, Mid2, High. The Auto-fan-speed mode enables speedy and comfortable air conditioning because the air flow speeds up when starting, and air flow slows down when the air conditioning becomes stable. (PLFY-P NBMU-E ONLY)
I-SEE SENSOR
i-see sensor can be used with ceiling cassette type 4-way airflow unit. (Option PAC-SA1ME-E, PLFY-NBMU only)
New 4-way Cassette PLFY-NBMU controls the temperature difference at the top and bottom in a room by checking the floor temperature with i-see sensor. Comfortable air conditioning can be realized smoothly with sensible temperature control. (Option PAC-SA1ME-E, PLFY-NBMU only)
INDUSTRY FIRST
*On the commercial air conditioners (according to the survey by Mitsubishi Electric)
The number of outlets can be set to 4, 3, or 2. Flexible airflow is available by fixing the up-down airflow direction of the outlet with a wired remote controller (or manually).
* Default * The ceiling may be smudged at a spot where the supplied airflow is seriously distributed.
77
SPECIFICATIONS
OPTIONAL PARTS
f1 Cooling / Heating capacity indicates the maximum value at operation under the following condition. Cooling: Indoor 80F (26.7C) D.B. / 67F (19.4C) W.B., Outdoor 95F (35C) D.B.Pipe length 25 ft. (7.6 m), Level difference 0 ft. (0 m)
Heating: Indoor 70F (21.1C) D.B., Outdoor 47F (8.3C) D.B. / 43F (6.1C) W.B.Pipe length 25 ft. (7.6 m), Level difference 0 ft. (0 m) f2 Airflow rate / Sound pressure level are in (low-middle2-middle1-high) or (low-middle-high). f3 It is measured in anechoic room.
www.CityMulti.ca
78
PLFY-P NBMU-E
PLFY-P12/15/18/24/30/36NBMU-E
Upper view
25/32~1-25/32(20~45) Fresh air intake hole Ceiling hole 33-27/32 to 35-13/16(860~910) 6-16/5 (160) 31-7/8(810) Suspension bolt pitch 25/32 to 1-25/32(20~45)
25/32 to 1-25/32 (20~45)
PLFY-P NCMU-E
PLFY-P08/12/15NCMU-E
Lower view
1-3/8(35)
25-19/32(650) 11-27/32(301) Air outlet hole
2-5/32(55)
6-5/16 (160)
(5/16) (7.5)
V/M V/M
24-13/32 (620)
33-1/16 (840)
5-29/32 (150)
25-19/32(650)
6-5/16 (160)
15/16 (24)
V/M V/M
(5/16) (7.5)
6-5/16 (160)
Lower view
23-1/2 (597) Air intake hole M M
37-3/8 (950) 23-1/2(597) Air intake hole 2-19/32(66)
Side view
11/16 (17) 7-15/16(202) 9-1/16(230)
7-19/32(193)
8-3/16(208)
M M 19-11/16 (500) Air outlet hole 37-3/8 (950) 1-27/64 (36) 3-17/64 (83)
Side view
(60) 2-3/8 (284) 11-3/16 (377) 14-27/32
1-27/64 (36)
6-11/16 (170)
5-1/2 (140)
Models
PLFY-P1215182430NBMU-E PLFY-P36NBMU-E
A
9-1/2 (241)
B
10-3/16 (258)
79
4-1/8 (105)
3-21/32(93)