OWNER KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT Document Title:

Date: 3/13/2013 Document No: DS-00-E-0015

CONTRACTOR

DATA SHEET FOR POWER TRANSFORMER


Rev: 1 Class: II Sheet 1 of 3

DATA SHEET FOR POWER TRANSFORMER

AS BUILT

1 0 A Rev

As Built Issued for Construction Issued for Approval Description

10/15/2009 26/10/2007 11/9/2007 Date

SB ARS/ SB ARS/ SB Prepared

ARS SN SN Checked

FT ShS ShS Approved LiuXG LiuXG CPECC Owner

OWNER KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT

CONTRACTOR

Document Title:
Date:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 GENERAL NOTES: 1. Fifteen (15) days notification to be given prior to testing. 2. TBA To Be Advised CABLE DETAILS Primary Winding Cable Details: Secondary Winding Cable Details: TBA TBA

DATA SHEET FOR POWER TRANSFORMER


Rev: 1 Class: II Sheet 2 of 3

3/13/2013 GENERAL-

Document No: DS-00-E-0015

Equipment Number: P.O. Number: Specification Requirements: Vendor: Manufacturer: Model Number: Serial Number:

ET-01 TBA SP-00-E-0011

ENVIRONMENTAL DATAMaximum Temperature: Minimum Temperature: Design Temperature (Min/Max): Maximum Humidity: Design Humidity: Altitude Above Sea Level: Transformer Location: Ingress Protection of Enclosure: 53 0C 06 0C 06/ 53 0C 57.5 % 58 less than 1000
Indoor
0

C C

Area Classification: Zone: Group: Temperature Class:


IIA

Hazardous 1 IIB

Non-Hazardous 2 IIC

% m
Outdoor

Maximum Sound Pressure Level at 1m:

85

dBA

IP 55

ELECTRICAL CHARACTERISTICSContinuous Rated Output: Primary Voltage: Secondary Voltage: Frequency: Number of Phases: Vector Group: System Earthing: Rated BIL: 2000 KVA 11 kV 0.415 50 3 Dyn 11 Directly Earthed 75 kV kV Hz Phase Tap Changer: Tapping Range : Insulation Class: Cooling Method Conservator: +/- 5% Class A ONAN
Required Not Required

On Load Tapping Step : Temperature Rise :

Off Circuit 2.5% Class A

CONTROL, ALARMS AND ACCESSORIES


Oil Temperature Indication: Winding Temperature Indication: Oil Level Indication Pressure Relief Vent Lower Oil Sample Valve Upper Fill/Filter Valve Integrated Protection Relay Buchholz Relay Required
Required Required Required

Not Required
Not Required Not Required Not Required

Required Required
Required Required

Not Required Not Required


Not Required Not Required

TRANSFORMER ARRANGEMENTTransformer Tank Type: Mounting Arrangement:


Sealed Pad Mount Conservator Pole Mount Dry Type Other

mm 2 mm 2

XLPE/SWA/PVC XLPE/SWA/PVC

mm OD mm OD

OTHERTropicalisation: Protective Coating: Neutral CT: Primary Side CT:


Required Not Required

Standard Required
Required

Other Not Required


Not Required

3. VENDOR to complete all missing information.

OWNER KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT Document Title:
Date:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Total Mass of Transformer Including All Fittings and Oil: Total Mass of Transformer Arranged for Transport: kg kg Oil Required: Oil Shipped Loose: Radiator Plate or Cooling Tube Thickness: mm Transformer Tank Thickness: Sides: Bottom: mm mm Overall Dimensions: Transformer Dimensions Arranged for Transport: Oil Level Gauge: Oil Temperature Indicator: Winding Temperature: Pumps Fans Primary Magnetising Current at Rated Voltage and Frequency: Maximum Winding Temperature at Rated Load:
o

CONTRACTOR

DATA SHEET FOR POWER TRANSFORMER


Rev: 1 Class: II Sheet 3 of 3

3/13/2013 GENERAL-

Document No: DS-00-E-0015

Equipment Number: P.O. Number: Specification Requirements: Vendor: Manufacturer: Model Number: Serial Number:

ET-01 TBA SP-00-E-0011

ELECTRICAL CHARACTERISTICSContinuous Rated Output: kVA Efficiency at 75oC: 50% load % No-load Loss (rated voltage, frequency): Load Loss (rated current, voltage, frequency at 75oC): Impedance voltage (rated current, frequency at 75oC): Reactance voltage (rated current, frequency at 75oC): kW kW % % Winding Material (HV/LV): A C Forced Cooling Pump/Fan Requirements: Voltage: Voltage Source: Quantity Make Model Power Pressure V Transformer Oil (type, grade): Regulation at Rated Power at 75oC: 0.8 PF % 1.0 PF % 75% load % 100% load %

MEASUREMENTMake Model Range

ACCESSORIESQuantity Gas Pressure Relief Outlet: Buchholz Relay: Integrated Protection Relay Upper Fill/Filter Valve: Make Model Range

TEMPERATURE RELAY SETTINGSTemperature High (Alarm): Temperature High High (Trip):


o o

Lower Oil Sample Cock: C C Neutral to Earth CT: Bushings: Surge Divertors: On-load Tap Changer: Off-circuit Tap Changer:

TRANSFORMER ARRANGEMENTHeight, mm Width, mm Depth, mm

Litres Litres

GENERAL NOTES: 1. All the above information shall be provided by the Vendor.