Professional Documents
Culture Documents
SPECIFICATIONS
Rated Voltage(V) Pole No Rated current (A) 1~10 220V 1P 15~32 380V 2,3,4P 40~60 100 50 30 15 0.1 Leakage Leakage action dead current(mA) current(mA) Leakage action time(s)
DZ47LE 2P
a.TH35-7.5 rail is used for the product installation. b.Outline and installation dimensions(see the figure and the table) Dimensions Type A DZ47LE-60/1N DZ47LE-60/2 DZ47LE-60/3 DZ47LE-60/3N DZ47LE-60/4 46 64 91 100 118 B 70 70 70 70 70 C 40 40 40 40 40 D 45 45 45 45 45 E 94 94 94 94 94
DZ47LE 3P
DZ47LE 4P
B-01
SPECIFICATIONS
RDX65LE 1P Number of Poles Rated voltage Rated current Rated Operating Current(mA) Rated non-operation (I n) Tripping Curve 1P+N, 2P+N, 3P+N, 4P+N 240/415V 6A 10A 16A 20A 25A 32A 40A 50A 63A 30mA 100mA 300mA 0.5I C,D n
RDX65LE 2P
SPECIFICATIONS
Number of Poles Rated Current(A) RDX2LE-100 2P+N Rated Residual Operating Current(I n)(mA) Rated Residual Non-operation Current(I no)(mA) Rated Voltage(V) Residual Current Off-time Short Circuit Capacity(Icu) Endurance Tripping Curve Portection Degree 1P+N,2P+N,3P+N,4P+N 40,50,63,80,100 30,50,100,200,300 0.5I n AC 230/400 0.1S 3000A 4000 C,D IP20
RDX2LE-100 3P+N
70 44
16
7.5
81
45
B-02
SPECIFICATIONS
Rated voltage Rated current Pole Rated operating current (mA) Rated non-operating (I N) Tripping curve Type 230/400V 6A 10A 16A 20A 25A 32A 40A 50A 63A 1P+N 2P 3P 4P 30mA 50mA 100mA 300mA 0.5I N
SPECIFICATIONS
Rated voltage Rated current Pole Rated operating current (mA) Rated non-operating (I N) Tripping curve 240/415V 6A 10A 16A 20A 25A 32A 40A 50A 63A 1P 2P 3P 4P 30mA 50mA 100mA 300mA 0.5I n
C type D type
B-03
DXM3L(DZ30L)
EARTH LEAKAGE CIRCUIT BREAKER
APPLICATIONS
DXM3L (DZ30L) leakage protective breaker, DXM3L(DZ30L) (phase wire+neutral wire+leakage +overload voltage) protective breaker is used in the single phase residence circuit of AC.5 0Hz/ 60Hz , rat ed voltage 220V, used as electron shock protection. It can protect civil electron circuit from
Test Monthly
over load and short-circuit. T his produc t has advantages of small volume, high breaking capacity zero, and live wires are cutted off at the same time, also protecting person fro m electric shock when the livewire connected opposite. This product conforms to IEC61009, Gb6829, GB/16917 .
DXM3L(DZ30L)
PC60NL
SPECIFICATIONS
PS250LE 2P Number of Pole Rated Current(A) Rated Residual Operating Current(I n)(mA) n)(mA) 1P+N,2P,3P+N,4P 40,50,63,80,100 30,50,100,200,300 0.5I n
Rated Residual Non-operation Current(I Rated Voltage(V) Residual Current Off-time Short Circuit Capacity(Icu) Endurance Tripping Type PS250LE 4P Protection Degree
B-04
Action function has nothing to do with main circuit voltage With midline cut-off functions, it is safer and more reliable. With double functional connection terminals, it has strong connection ability. With contact state indicator, it is easy to recognize the contact situation. Different handle colors are used to indicate different rated current. High breaking capacity:10KA With wide range of rated current, it can be used as family main switch United accessories series Type can provent the error tripping caused by electric equipment
RDX6LE-63
SPECIFICATIONS
Pole No. Standards Rated Current Rated eakage Current I n Rated Voltage(Ue) Tripping Time Sensitivity Type Breaking Capacity Icn Tripping Characteristic RDX6LE-63 Grade of Protection Service Life Terminal Connection Shell width 3 10KA C,D IP40 Electric:no less than 4000 times Machanic:no less than 20000 times Wire 1-25 square micron Bus-bar row thickness 0.8-2mm Din Rail 35mm(Two modulus in width) 2 P IEC61009(EN61009)GB16917.1 Type C 6,10,13,16,20,25,32,40A Type D 6,10,13,16,20A 30,100mA 230V;50Hz G Minimum 10ms for prolonging AC type
MOUNTING DIMENSION
5.5 30.5 4.5
1P+N
80
N
35
44 60
B-05
45 9.5
SPECIFICATIONS
Number of Pole Rated Current(A) Rated Residual Operating Current(I Rated Voltage(V) PID 2P Residual Operating Current Scope Residual Current Off-time Short Circuit Capacity(Icu) Endurance Protection Degree n)(mA) 1P+N,3P+N 16,20,25,40,50,63 30,100,300,500 AC 230/240 AC400/415 0.5I n~1I 0.3S 6000A 4000 IP20 n
Installation method DIN Rail mounting type. The external magnetism shall not be more than 5 times of terrestrial one. PID 4P Product shall be installed vertically at the place where there shall be no severe impact or vibration. The product is switched on when the handle is at upper position.
74.5
N
36
N
72
35.5
85
O.OFF
O.OFF
B-06
65 85
65
Equipped with finger protected connection terminals Automatically disconnect the circuit when earth fault/ leakage current occurs and exceeds the rated sensitivity. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
PID-N 2P
TECHNICAL DATA
Pole No.: 2, 4 Rated current(A): 25, 40, 63 Rated voltage: 230/400V AC Rated frequency: 50/60Hz Mode: electro-magnetic type, electronic type Residual current characteristics: A, AC Rated making and breaking capacity: 630A Rated residual operating current I n(mA): 10, 30, 100, 300, 500 Rated residual non-operating current I no: 0.5I n Rated conditional short-circuit current Inc: 6000A Rated conditional residual short-circuit Current I c: 6000A Tripping duration: instantaneous tripping 0.1s Residual tripping current range: 0.5I n~1I n Electro-mechanical endurance: 4000 cycles Connection capacity: Rigid conductor 25mm2 Connection terminal: Screw terminal Pillar terminal with clamp Fastening torque: 2.0Nm Installation: On symmetrical DIN rail 35mm Panel mounting
PID-N 4P
WIRING DIAGRAM
B-07
ELECTRICAL
PF7 2P
Design according to Tripping time ICE61008 (EN 61008) undelayed min.10 ms delay min.40 ms delay with selective disconnecting function 230/400V; 50Hz 10,30,100,300,500mA AC and pulsating DC 10KA with 63A gL back-up fuse 10KA with 80A gL(F7-80 and-863) 6KA(rated current 63A) with 63A gL 63A gL 80A gL (F7-80 and-863) 45A gL(F7-25 and-40A) 40A gL(F7-80 A) according to IEC 61008 built-in switch IP 40 4.000 operating cycles 20.000 operating cycles
Rated voltage Rated tripping current Sensitivity Rated short Circuit strength Maximum back-up fuse for Short circuit protection Maximum back-up fuse for Oveload protection Resistance to climatic conditions Degree of protection Endurance electrical comp. mech comp.
PF7 4P
MECHANICAL
Frame size Socket size Device width Mounting Upper and lower terminals Terminal protection
45mm 80mm 35mm (2mod.), 70mm (4mod.) quick fastening with 2 lock-in Positions on DIN rail En50022 open mouthed/lift terminals finger and hand touch safe, VBG 5, OVE-EN 6 1 --- 25mm2 0.8 - 2mm
B-08
SPECIFICATIONS
Type Rated current In (A) Rated operating current for earth leakage I n(A) Rated non-operating current for earth leakage I n(A) Voltage Un(V) Pole PNFIN25 PNFIN40 PNFIN63 PNFIN100 25 40 63 100 0.03,0.1,0.3,0.5 0.1,0.3,0.5 0.5I n 415(380)V 240(220)V 2,4
PNFIN 2P
PNFIN 4P
PFIN 2P
SPECIFICATION
Type Rated current In (A) Rated operating current for earth leakage I n(A) Rated non-operating current for earth leakage I n(A) Voltage Un(V) Pole PFIN25 PFIN40 PFIN63 PFIN100 25 40 63 100 0.03,0.1,0.3,0.5 0.1,0.3,0.5 0.5I n 415(380)V 240(220)V 2,4
PF1-4P
B-09
SPECIFICATION
Number of Pole Rated Current (A) Rated Residual Operating Current (I n)(mA) Rated Residual Non-operation Current (I no)(mA) PF362 2P Rated Voltage (V) Residual Operating Current Scope Residual Current Off-time Short Circuit Capacity (Icu) Endurance Protection Degree 2P,4P 16,20,25,32,40,50,63,80,100 10,30,100,300,500 0.5 I n AC 230/240 AC 400/415 0.5I n~1I n 0.3S 3000A 4000 Ip20
OPERATION PRINCIPLE
7 N
I>
PF364 4P
2 4 2 4 6 8 N
I>
35 17.5 17.5 2
17.5 2
17.5 2
90.4
90.4 71 46
90.4 71 7.5
46
7.5
B-10
NUISANCE TRIPPING
PRC 2P All the RCCBs are protected against transient voltages (lightenin g, line disturbances)and transient currents (from high capacitive circuits) DC sensitive RCCBs or time delay devices are available, please consult us you also have the possibiliy to install the following accessories: electrical cover kit, locking kit.
Sensitivity High sensitiviy:10mA
Current rating 16A 25A 16A 25A 40A 63A 80A 100A 25A 40A 63A 80A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 10 sets 10 sets 10 sets 10 sets
cat.ref. PRC216B PRC225B PRCD216B PRCD225B PRCD240B PRCD263B PRCD280B PRCD284B PRCD425B PRCD440B PRCC463B PRCD480B PRCE225B PRCE240B PRCE263B PRCE280B PRCE284B PRCE425B PRCE440B PRCE463B PRCE480B PRCE484B PRCF225B PRCF240B PRCF263B PRCF280B PRCF284B PRCF425B PRCF440B PRCF463B PRCF480B PRCF484B PRCG225B PRCG240B PRCG263B PRCG280B PRCG284B PRCG425B PRCG440B PRCG463B PRCG480B PRCG484B PRCZ005 PRCZ006 PRCZ007 PRCZ008
30mA
PRC 4P
Medium sensitivity:100mA
Low sensitivity:300mA
PRCC 2P
Low sensitivity:500mA
PRCC 4P
B-11
APPLICATION
PR101 Series Earth Leakage Circuit Breakers apply to in AC circuit of frequency of 50 Hz, rated voltage up to 415V rated current up to 80A. It is mainly use d as an indi rect con tact , protection fot human. It also can be used to preven t aga inst the f ire d anger caus ed b y ea rth falt current ow ing to equipment insulation damage. When the protective measures of the electric shock are out of work, the RCCB whose rated residual operating current less than 30mA can serve as the supplementary protection for in direct contact, but it can t be used as the sole direct contact protection.
PRODUCT FEATURES
1. PR101 Series Leakage Circuit Breakers are the protector for pure electromagnetic residual current operation. 2. The operation function is unrelated to circuit voltage, but operation is reliable. 3. It can be reliably operated on the loss of phase or neutral. 4. The capacity of resisting electromagnetic interference is strong.
PR101 2P
PR101 4P
DIMENSIONS
45 91
72
54 43.7 6.5
36
TH35
90 Y1Y2
L1 L2 L3 N PE
90 45
13 5 N
12-6672
M A B 24 6 N W1 T
44 64
B-12
Rated voltage Rated tripping current Sensitivity Rated short Circuit strength PBV-D 2P Maximum back-up fuse for Short circuit protection Maximum back-up fuse for Overload protectiton Resistance to climatic conditions Degree of protection Endurance electrical comp. mech comp
MECHANICAL DATA
Frame size Socket size Device width Mounting Upper and lower terminals Terminal protection Terminal capacity Busbar thickness 45mm 80mm 35mm (2mod.), 70mm (4mod.) quick fastening with 2 lock-in Positions on DIN rail En50022 open mouthed/lift terminals finger and hand touch safe, VBG 5, OVE-EN 6 1 --- 25mm2 0.8 - 2mm
PBV-D 4P
B-13
SPECIFICATIONS
Number of Pole Rated Voltage(V) PG230 Rated Current(A) Leakage Motion Current(mA) Leakage Dead Current(mA) 2 4
210
PG430
210
53 70 70 115
53 70
APPLICATION
TG RCCB, rated current is adjustable from 10A up to 60A. User can select suitable current for better protection against overload and short circuit.The products comply with IEC61008.
SPECIFICATIONS
Number of Pole Rated Voltage(V) Rated Current(A) Leakage Motion Current(mA) TG430 Leakage Dead Current(mA) 2 4
B-14
PL9 2P
SPECIFICATIONS
Number of Pole Rated Current(A) Rated Residual Operating Current(I n)(mA) n)(mA) 2P,4P 40,50,60 30,100,300 0.5I n
Rated Residual Non-operation Current(I Rated Voltage(V) Residual Current Off-time Short Circuit Capacity(Icu) Endurance PL9 4P Protection Degree
SPECIFICATIONS
Type
PDBR230
PDBR430
Poles
2P
4P
250V/440V
5A-15A,10-30A,30-60A Adjustable
300mA
500mA
1000mA
150mA
250mA
500mA
NFC61450
B-15
INSTRUCTIONS
This RCCB is intended for installation within an enclosure in an a mbient tem perature between -5 CBT 2P and 40 with an average value not exceeding 35 over a 24 hours perio d. It shou ld not be installed at an altitude greater than 2000m above sea level, nor in an atmosphere subject to excessive pollution by smoke, dust, chemical fumes, salt laden spray, prolonged periods of high humidity or other abnormal conditions. See current product catalogues for a wide range of suitable enclosure.
PL13-03
B-16
GFCI RECEPTACLE
RECEPTACLE
DESCRIPTION
GFCI, Duplex Receptacle With red Reset Button and blue Test button 20A, 125V AC, 60Hz, With LED light Indicator
ART.NO.
PTG15-L-2AL PTG15-L-2DE PTG15-L-2BL PTG15-L-2GR PTG15-L-2IV PTG15-L-2WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
RED RESET/ BUTTON TEST
PTG15-L
DESCRIPTION
GFCI, Duplex Receptacle Buttons Match body face color 20A, 125V AC, 60Hz, With LED light Indicator
ART.NO.
PTG20-L-1AL PTG20-L-1DE PTG20-L-1BL PTG20-L-1GR PTG20-L-1IV PTG20-L-1WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
PTG20-L
DESCRIPTION
GFCI, Duplex Receptacle With red Reset Button and blue Test button 20A, 125V AC, 60Hz, With LED light Indicator PTG20-L
ART.NO.
PTG20-L-2AL PTG20-L-2DE PTG20-L-2BL PTG20-L-2GR PTG20-L-2IV PTG20-L-2WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
RED RESET/ BUTTON TEST
3 Grace Switch can control resistance and inductance load which meets residential use and commercial use for its reliability and unique performance. Switch Characteristics Large head double-drive combination screws for quick wiring Back and side wire connection are easy to be installed Green grounding screw Choice of different color
B-17
GFCI RECEPTACLE
RECEPTACLE
DESCRIPTION
GFCI, Duplex Receptacle With red Reset Button and blue Test button 20A, 125V AC, 60Hz,
ART.NO.
PTG15-2AL PTG15-2DE PTG15-2BL PTG15-2GR PTG15-2IV PTG15-2WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
RED RESET/BUTTON TEST
PTG15
DESCRIPTION
GFCI, Duplex Receptacle Buttons Match body face color 20A, 125V AC, 60Hz.
ART.NO.
PTG20-1AL PTG20-1DE PTG20-1BL PTG20-1GR PTG20-1IV PTG20-1WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
PTG20
DESCRIPTION
GFCI, Duplex Receptacle With red Reset Button and blue Test button 20A, 125V AC, 60Hz, PTG20
ART.NO.
PTG20-2AL PTG20-2DE PTG20-2BL PTG20-2GR PTG20-2IV PTG20-2WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
RED RESET/ BUTTON TEST
DESCRIPTION
GFCI, Duplex Receptacle Buttons Match body face color 15A, 125V AC, 60Hz. PTG15-L With LED light indicator
ART.NO.
PTG15-L-1AL PTG15-L-1DE PTG15-L-1BL PTG15-L-1GR PTG15-L-1IV PTG15-L-1WH
BODY COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
BUTTON COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORY WHITE
B-18
GFCI RECEPTACLE
RECEPTACLE
PTM-1 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES
DESCRIPTION
Single-pole Toggle Switch With Grounding Screw Quick Wiring and Side Wiring
ART. N0.
PTM-1AL PTM-1DE PTM-1BL PTM-1GR PTM-1IV PTM-1WH
COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORV WHITE
PTM-2 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES
DESCRIPTION
3-Way Toggle Switch With Grounding Screw Quick Wiring and Side Wiring
ART. N0.
PTM-2AL PTM-2DE PTM-2BL PTM-2GR PTM-2IV PTM-2WH
COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORV WHITE
PTM-3 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES
DESCRIPTION
Single-pole Decorative Switch Screw Quick Wiring and Side Wiring
ART. N0.
PTM-3AL PTM-3DE PTM-3BL PTM-3GR PTM-3IV PTM-3WH
COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORV WHITE
PTM-4 QUICKWIRE AND SIDE WIRED TOGGLE 15AMP 120V AC QUICK SWITCHES
DESCRIPTION
3-WayDecorative Switch With Grounding Screw Quick Wiring and Side Wiring
ART. N0.
PTM-4AL PTM-4DE PTM-4BL PTM-4GR PTM-4IV PTM-4WH
COLOR
ALMOND DEEP-ALMOND BLACK GRAY IVORV WHITE
B-19
GFCI RECEPTACLE
RECEPTACLE
RECEPTACLE CHARACTERISTICS
Additional assembly screw Side wire connection and 8 holes back quick wire connection Choice of different color Green grounding screw Large head double-drive combination screws for quick wiring
DESCRIPTION
ART. N0.
PTMSR-15/1J-AL PTMSR-15/1-AL PTMSR-15/1JED PTMSR-15/1ED PTMSR-15/1JBL PTMSR-15/1BL PTMSR-15/1JGR PTMSR-15/1GR PTMSR-15/1JIV PTMSR-15/1IV PTMSR-15/1JWH PTMSR-15/1WH
COLOR
Standard Duplex Receptacle 15A, 125V AC With 1J PTMSR-15/1J Clip 1 for Standard wire , for Self-grounding
DESCRIPTION
ART. N0.
PTMSR-15/2J-AL PTMSR-15/2-AL PTMSR-15/2JED PTMSR-15/2ED PTMSR-15/2JBL PTMSR-15/2BL PTMSR-15/2JGR PTMSR-15/2GR PTMSR-15/2JIV PTMSR-15/2IV PTMSR-15/2JWH PTMSR-15/2WH
COLOR
Standard Duplex Receptacle 15A, 125V AC With 2J PTMSR-15/2J Clip 2 for Standard wire , for Self-grounding
B-20