Data Sheet
Standards
The motors comply with all the relevant standards and specifications, particularly those given in table A.
Ambient Temperature
All motors in normal design are suitable for an ambient temperature up to 50C.
Degree of Protection
Motors are designed for degree of protection IP 55 according to IS:4691
Rating Plate
The 50Hz data, and marking are provided on the rating plate of all motors. A typical rating plate will be as shown on the right. As the efficiency values meet minimum norms of energy efficient motors as per IS : 12615-2004 for corresponding outputs, EFF2 logo will be provided for motors of 0.37kW and above.
Service Factor
All standard motors have a service factor of 1.1, when operating at rated supply conditions, ambient temperature up to 50C and altitude up to 1000m, with temperature rise limited to class F limits.
Frame design
The frames are of Cast Iron Grade FG150 as per IS:210. Terminal boxes of all the motors are of aluminium. The motors can be offered in footmounted construction (IMB3, IMB6, IMB7, IMB8, IMV5, IMV6) or in flange mounted construction (IMB5, IMV1, IMV3). Foot cum flange construction B35, facemounting construction with C type flange B14 and face mounting construction with C type flange along with foot B34 are also available. All foot mounted motors in frames 63 to 132 are with integral mounting feet. The motors are suitable for horizontal as well as vertical mounting - universal type of construction.
Output
The rated output, as given in the selection and ordering data, is applicable for continuous operation as per IS:325 at 415V, 50Hz supply, ambient temperature up to 50C and altitude upto 1000m above mean sea level. The motors are provided with Class F insulation, thermally utilised to Class B limits, at rated output and rated voltage / frequency and with sinusoidal supply. For use of standard motors at ambient temperatures exceeding 50C and/or altitudes exceeding 1000m above mean sea level, the multiplication factors as listed in the table below must be applied on the rated output. By utilising to Class F limits, at rated voltage and frequency, the rated output can be derived from these motors even if the ambient temperature goes upto 55C.
Winding Connection
The motors rated up to 1.5kW will be Star connecred for 415V / 50Hz supply, and 6 leads will be brought out to the terminal box. The motors rated 2.2kW and above will have 6 leads of the windings brought out in the terminal box and have to be connected in Delta for 415V / 50Hz supply.
Paint
The normal paint is in shade RAL 7037 (Dusty Grey). This paint is suitable for climate group worldwide as per DIN IEC 60721 Part 2-1, and also for aggressive Altitude above sea level in m 1000 1500 2000 2500 3000 3500 4000
Overload Capacity
The motors are capable of withstanding 1.5 times the rated current at rated voltage and rated frequency for 2 minutes.
Insulation
Insulation system comprises dual coat enameled wires with a temperature class 200 and widely proven NOMEX based insulating material combined with alkydbased varnish. The system ensures high 2
Terminal box
The terminal boxes for all the motors are mounted on top. The particulars are given in the table below :-
Table B
Frame Size 63, 71, 80, 90 100, 112, 132 T.B. Type 1 x B0 096 1 x B0 132 Terminal screw in mm M4 M5 Max. permissible cond. Ross-section area in mm2 1x4 2x6
o
Bearing Design
Deep groove ball bearings, series 62 shielded on both the sides (ZZ), with bearing clearance Normal are provided on motors up to and including 112M frame. Frame size 132 will be provided with C3 clearance. The grease used is lithium complex soap based, Exxon Mobil, UNIREX N3, to NLGI Class 3. References for the bearings are given in the following table: Frame size 63 71 80 90 100 112 132 Bearing reference DE 6201 ZZ 6202 ZZ 6204 ZZ 6205 ZZ 6206 ZZ 6206 ZZ 6208 ZZ NDE 6201 ZZ 6202 2Z 6204 ZZ 6205 ZZ 6206 ZZ 6206 ZZ 6208 ZZ
Table A
Title General requirements for rotating electrical machines Fixing dimensions and assignment of rated outputs with IMB3 construction (foot mounted) Fixing dimensions and assignment of rated outputs with IMV1, IMB5, IMB10 and IMB14 construction (flange mounted) Types of construction of rotating electrical machines Degree of protection by enclosures for rotating electrical machinery Standard voltages Voltage Variation % 6 10 12.5 15 Frequency Variation % 3 5 5 5 IEC IEC 60034-1 IEC 60085 IEC 60072 Equivalent IS IS 4722 IS 325 IS 1231 (dimensions only) IS 2223 (dimensions only) IS 2253 IS 4691 IS 12360 Permissible Output as % of Rated Value 100 100 95 90
IEC 60072 (dimensions only) IEC 60034-7 IEC 60034-5 IEC 60038 Combined Voltage and Frequency Variation % 9 10 12.5 15
Noise Level
No-load noise level for motors will be in accordance with IS:12065.
IMB35
IMB5
IMB34
IMB14
IMB3 3
kW
rpm
kgfm
kgfm2
kg
3000 rpm, 2 pole, 50 Hz 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 9.3 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 3.7 5.5 7.5 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 63 63 71 71 80 80 90S 90L 100L 112M 132S 132M 63 63 71 71 80 80 90S 90L 100L 100L 112M 132S 132M 71 71 80 80 90S 90L 100L 112M 132S 132M # 1LA0 060-2YA.. # 1LA0 063-2YA... # 1LA0 070-2YA... # 1LA0 073-2YA... # 1LA0 080-2YA... # 1LA0 083-2YA... # 1LA0 090-2YA... 1LA0 096-2YA... 1LA0 107-2YA... 1LA0 114-2YA... 1LA0 131-2YA... 1LA0 133-2YA... # 1LA0 060-4YA... # 1LA0 063-4YA... # 1LA0 070-AYA.. # 1LA0 073-4YA.. # 1LA0 080-4YA.. # 1LA0 083-4YA.. # 1LA0 090-4YA.. # 1LA0 096-4YA.. 1LA0 106-4YA.. 1LA0 107-4YA.. 1LA0 113-4YA.. 1LA0 130-4YA.. 1LA0 133-4YA.. # 1LA0 070-6YA... # 1LA0 073-6YA.. # 1LA0 080-6YA... # 1LA0 083-6YA.. # 1LA0 090-6YA... # 1LA0 096-6YA.. # 1LA0 106-6YA.. 1LA0 113-6YA.. 1LA0 131-6YA.. 1LA0 134-6YA.. 0.47 0.67 0.91 1.3 1.7 2.3 3.1 4.3 7.1 10 13.3 16.4 0.51 0.57 0.76 1.05 1.4 1.8 2.5 3.3 4.4 6 7 10.5 14 0.61 0.8 1.1 1.5 2.0 2.9 3.5 4.9 7.6 10.9 63.0 63.0 67.0 72.0 73.0 77.0 78.5 81.0 84.0 85.7 87.0 87.7 55.0 60.0 62.0 66.0 73.0 74.0 76.5 79.0 82.0 82.6 85.0 87.5 87.5 60.0 64.0 65.0 69.0 71.0 75.0 76.0 79.5 82.5 84.5 0.84 0.82 0.84 0.83 0.85 0.87 0.87 0.88 0.86 0.89 0.90 0.90 0.60 0.73 0.74 0.74 0.73 0.80 0.81 0.81 0.85 0.84 0.86 0.83 0.85 0.68 0.68 0.73 0.74 0.72 0.71 0.78 0.78 0.82 0.83 2770 2770 2780 2840 2840 2850 2860 2880 2900 2905 2910 2915 1340 1370 1360 1380 1410 1415 1415 1415 1435 1435 1440 1450 1450 900 900 910 915 920 930 950 940 950 945 0.06 0.09 0.13 0.19 0.26 0.38 0.51 0.74 1.2 1.8 2.5 3.1 0.09 0.13 0.18 0.26 0.38 0.52 0.76 1.0 1.5 2.0 2.5 3.7 5.0 0.19 0.27 0.40 0.59 0.79 1.2 1.5 2.3 3.8 5.7 4.5 4.5 4.5 4.5 5.5 5.5 6.0 6.0 5.5 6.0 6.0 6.0 3.5 3.5 3.5 3.5 4.3 4.5 4.7 4.7 5.5 5.5 5.5 5.5 5.5 3.0 3.0 4.0 4.0 5.0 5.0 4.0 5.0 4.5 5.0 2.0 2.0 2.4 2.4 2.3 2.2 2.7 2.7 2.1 2.5 2.0 2.0 1.9 1.9 1.9 1.9 2.0 2.0 2.2 2.2 2.4 2.4 2.2 2.3 2.3 1.9 1.9 2.1 2.1 2.3 2.5 2.0 2.0 1.9 2.0 2.3 2.3 2.7 2.7 2.6 2.5 3.0 3.0 2.3 2.8 2.3 2.3 2.1 2.1 2.1 2.1 2.2 2.1 2.5 2.5 2.6 2.6 2.5 2.5 2.5 1.9 1.9 2.1 2.1 2.3 2.5 2.3 2.3 2.2 2.3 0.0010 0.0010 0.0016 0.0022 0.0038 0.0049 0.0072 0.0093 0.0200 0.0373 0.0583 0.0716 0.0008 0.0010 0.0016 0.0022 0.0038 0.0049 0.0072 0.0093 0.0182 0.0237 0.0380 0.0676 0.0912 0.0033 0.0033 0.0049 0.0063 0.0095 0.0122 0.0269 0.0467 0.0826 0.1156 5 6 8 9 13 14 18 21 31 41 58 65 5 6 8 9 13 14 18 20 28 32 39 57 64 8 8 12 13 17 19 29 39 58 66
# 415V, Star connected All values subject to tolerance as per IS 325 Order No Suffixes
Motor Type Last place but one : Figure denoting voltage 415V, 50Hz Standard V and F variation 1LA0 063 to 096 1LA0 106 to 134 8 8 * Other Voltage and/or Frequency (& voltage and frequency variation) 9 9 IMB3 IMB5 Last place : Figure denoting construction At additional price IMV1 without canopy 1 1 IMV1 with canopy 4 4 IMB14 IMB34 IMB35
0 0
1 1
2 2
7 7
6 6
Special Designs
The following special features/accessories can be provided on the motors, on request-
Non-standard output Non-Standard voltage and/or frequency 3 numbers PTC thermistors for trip Anticondensation heaters - Frame 112 and 132 only Epoxy coating on winding overhangs Non-standard paint shade Epoxy based paint Unpainted, only with primer
Variable speed drive motor Standard double shaft extension Side mounted terminal box - Frames 90, 100,112 and 132 only Non-standard ambient - upto 55oC Additional name plate Cast Iron external fan Fan cowl with Canopy or clean flow fan cowl Fan cowl without screen and with canopy
8.20 8.10
20.00
10.50
4.00 5.00
5.10
10.00
10.15
3.00 Rolling contact bearing assembly (fixed bearing) 4.00 Rolling contact bearing assembly (floating bearing) 5.00 Endshield drive end 5.10 Flange endshield 6.00 Endshield, non-drive end 8.10 Shaft 8.20 Cage rotor
10.00 Stator housing with integral feet and wound core packet 10.15 Earthing clamp 10.50 Lifting eyebolt 11.00 External fan 12.01 Fan Cowl 20.00 Terminal box 12.70 Canopy
Note: The graphic displayed here is solely for the purpose of explaination. The actual product may be different in appearance.
Dimensions in mm
c B is valid in all frames d B & CA are valid for 90 frame only 90S: B=100 & CA=128,
90L: B=125 & CA=103 e Terminal box can be rotated in steps of 90O
d
140 140 140 178
d
117 134 149 149
Shaft Extension Frame Size 63 71 80 90S/L 100L 112M 132S 132M HB HD K 7 7 10 10 12 12 12 12 L 208 240 282 326 373 398 452 490 LC 236 272 326 374 430 454 538 576 LL 89 89 89 89 112 112 112 112 D 11 14 19 24 28 28 38 38 Drive End DB E M4x9 M5x12 M6x16 M8x20 M10x24 M10x24 M12x28 M12x28 23 30 40 50 60 60 80 80 F 4 5 6 8 8 8 10 10 GA 12.5 16 21.5 27 31 31 41 41 DA 11 14 19 19 24 24 38 38 Non-drive End DC EA FA M4x9 M5x12 M6x16 M6x16 M8x20 M8x20 M12x28 M12x28 23 30 40 40 50 50 80 80 4 5 6 6 8 8 10 10 GC 12.5 16 21.5 21.5 27 27 41 41
194.5 223 224.5 256 249.5 281 289 289 320 320
Definitive Dimensions: A, B, B, C, H, K, D, E, F, GA are binding dimensions for all standard motors. All other dimensions are subject to change. For valid dimensions, please contact Regional Office in your region
Dimensions in mm
c Shaft extension as per IS:1231 d Measured over bolt heads e Terminal box can be rotated in steps of 90O
LE 23 30 40 50 60 60 80 80
Shaft Extension Frame Size 63 71 80 90S/L 100L 112M 132S D 11 14 19 24 28 28 38 Drive End DB E F M4x9 M5x12 M6x16 M8x20 23 30 40 50 4 5 6 8 8 8 10 10 GA 12.5 16 21.5 27 31 31 41 41 DA 11 14 19 19 24 24 38 38 Non-drive End DC EA FA M4x9 M5x12 M6x16 M6x16 M8x20 M8x20 23 30 40 40 50 50 4 5 6 6 8 8 10 10
g
GC Number LA 12.5 16 21.5 21.5 27 27 41 41 F115B F130B F165B F165B F215B F215B F265B F265B 9 9 10 10 11 11 12 12 M 115 130 165 165 215 215 265 265 N 95 P 140 S 10 10 12 12 15 15 15 15 T 3 3.5 3.5 3.5 4 4 4 4
110 160 130 200 130 200 180 250 180 250 230 300 230 300
M12x28 80 M12x28 80
Definitive Dimensions: M, N, S, D, E, F, GA and LA are binding dimensions for all standard motors. All other dimensions are subject to change. For valid dimensions, please contact Regional Office in your region