Simulator/AC Input Modules

F2-08SIM Input Simulator


Inputs per Module Base Power Required 5VDC Terminal Type Status Indicator Weight
8 50 mA None Switch side 2.65 oz. (75 g)

<--->

D2-08NA-1 AC Input
Inputs per Module Commons per Module Input Voltage Range Peak Voltage ON Voltage Level OFF Voltage Level AC Frequency Input Impedance Input Current Minimum ON Current Maximum OFF Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight
8

<--->

1 (2 I/O terminal points) 80-132 VAC 132 VAC 75 VAC minimum 20 VAC maximum 47-63 Hz 12 k @ 60 Hz 13 mA @ 100 VAC, 60 Hz 11 mA @ 100 VAC, 50 Hz 5 mA 2 mA 50 mA 5 to 30 ms 10 to 50 ms Removable; D2-8IOCON Logic side 2.5 oz. (70 g)

IN 0 1 2 3 F 2--08SI M 0 1 2 3 4 5 6 7

SIM 4 5 6 7

> ON

See the Terminal Blocks and Wiring section in this catalog for part numbers of ZIPLink cables and terminal blocks compatible with this module.
Points
8 6 4 2 0 0 32 10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F )

Derating Chart

IN 0 1 2 3 D2--08NA--1
80-132VAC 10-20mA 50/60Hz

110 VAC 4 5 6 7

110 VAC

C C 0 4 1 5 2 6 3 7

Internally connected

C C 0 4 1 5 2 6 3
V+

Internal module circuitry

7
D2--08NA-1

INP UT To LE D

COM
Line

Optical Is olator

110 VAC COM

484

PLC Products

1 - 80 0 - 633 - 0405

AC Input Modules
D2-08NA-2 AC Input
Inputs per Module Commons per Module Input Voltage Range Peak Voltage ON Voltage Level OFF Voltage Level AC Frequency Input Impedance Input Current Minimum ON Current Maximum OFF Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight
Points
8 6 4 2 0 0 32 10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F ) 0 4 1 5
Internal module circuitry

PLC Overview DL05/06 PLC

<--->
Operating Temperature Storage Temperature Humidity Atmosphere Vibration Shock Insulation Withstand Voltage Insulation Resistance Noise Immunity RFI
32F to 131F (0 to 55C) -4F to 158F (-20C to 70C) 35% to 95% (non-condensing) No corrosive gases permitted MIL STD 810C 514.2 MIL STD 810C 516.2 1,500 VAC 1 minute (COM-GND) 10M s 500 VDC NEMA 1,500V 1 minute SANKI 1,000V 1 minute 150 MHz, 430 MHz

8 1 (2 I/O terminal points) 170-265 VAC 265 VAC 150 VAC minimum 40 VAC maximum 47-63 Hz 18 k @ 60 Hz 9mA @ 220 VAC, 50 Hz 11 mA @ 265 VAC, 50 Hz 10 mA @ 220 VAC, 60 Hz 12 mA @ 265 VAC, 60 Hz 10 mA 2 mA 100 mA 5 to 30 ms 10 to 50 ms Removable; D2-8IOCON Logic side 2.5 oz. (70 g)

DL105 PLC DL205 PLC DL305 PLC DL405 PLC Field I/O Software C-more HMIs Other HMI AC Drives Motors Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Pushbuttons/ Lights Process Relays/ Timers

Derating Chart

220VAC

C C

Internally connected

V+

2 6

INP UT To LE D

Comm. TBs & Wiring Power Enclosures Appendix Part Index

3 7

COM 220VAC COM

Optical Is olator

w w w. a u to m at i o n d i re c t . c o m / d l 205

PLC Products

485

AC Input Modules
D2-16NA AC Input
Inputs per Module Commons per Module Input Voltage Range Peak Voltage ON Voltage Level OFF Voltage Level AC Frequency Input Impedance Input Current Minimum ON Current Maximum OFF Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight
16 2 (isolated) 80-132 VAC 132 VAC 70 VAC minimum 20 VAC maximum 47-63 Hz 12 k @ 60 Hz 11 mA @ 100 VAC, 50 Hz 13 mA @ 100 VAC, 60 Hz 15 mA @ 132 VAC, 60 Hz 5mA 2mA 100 mA 5 to 30 ms 10 to 50 ms Removable; D2-16IOCON Logic side 2.4 oz. (68g)

<--->

Points
16 12 8 4 0 0 32

Derating Chart

See the Terminal Blocks and Wiring section in this catalog for part numbers of ZIPLink cables and terminal blocks compatible with this module.

IN A 0 1 2 B 3 D2--16NA
80-132VAC 10-20mA 50/60Hz

10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F )


110 VAC
0 4 1 5 2 6 3 7 CA

110 VAC 4 5 6 7

0 1 2 3 NC 0 1 2 3

CA 4 5 6 7 CB 4 5 6 7

110 VAC

NC CB 0 4 1 5 2 6 3 7

Internal module circuitry V+ INP UT To LE D Optical Is olator D2--16NA

COM 110 VAC

486

PLC Products

1 - 80 0 - 633 - 0405

AC Output Modules
D2-08TA AC Output
Outputs per Module Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
8 1 (2 I/O terminal points) SSR (Triac) 15-264 VAC 264 VAC < 1.5 VAC (>0.1A) < 3.0 VAC (<0.1A) 47 to 63 Hz 10 mA 0.5A/point; 4A/common 4mA (264 VAC, 60 Hz) 1.2 mA (100 VAC, 60 Hz) 0.9 mA (100 VAC, 50 Hz) 10 mA for 10 ms 250 mA 1ms 1ms + 1/2 cycle Removable; D2-8IOCON Logic side 2.8 oz. (80g) 1 per common, 6.3A slow blow replaceable order D2-fuse-3

PLC Overview

<--->

F2-08TA AC Output
Outputs per Module Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current Max Leakage Current Peak One Cycle Surge Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
8 2 (Isolated)

<--->

DL05/06 PLC DL105 PLC DL205 PLC DL305 PLC DL405 PLC Field I/O Software C-more HMIs Other HMI AC Drives Motors Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Pushbuttons/ Lights Process Relays/ Timers Comm. TBs & Wiring Power Enclosures Appendix Part Index

SSR (Triac with zero crossover) 24-140 VAC 140 VAC 1.6 V(rms) @ 1.5A 47 to 63 Hz 50 mA 1.5A / pt @ 30C 1.0A / pt @ 60C 4.0A / common; 8.0A / module @ 60C 0.7 mA(rms) 15A 250 mA 0.5 ms - 1/2 cycle 0.5 ms - 1/2 cycle Removable; D2-8IOCON Logic side 3.5 oz. None

See the Terminal Blocks and Wiring section in this catalog for part numbers of ZIPLink cables and terminal blocks compatible with this module.

Derating Note: All outputs can be run at the current per point shown. There is no derating for the number of I/O points used.

w w w. a u to m at i o n d i re c t . c o m / d l 205

PLC Products

491

AC Output Modules
D2-12TA AC Output
Outputs per Module Outputs Points Consumed Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
12 16 (four unused, see chart below) 2 (isolated) SSR (Triac) 15-132 VAC 132 VAC < 1.5VAC (>50mA) < 4.0VAC (<50mA) 47 to 63 Hz 10 mA 0.3A/point; 1.8A/common 2mA (132 VAC, 60 Hz) 10A for 10 ms 350 mA 1ms 1ms + 1/2 cycle Removable; D2-16IOCON Logic side 2.8 oz. (80g) (2) 1 per common 3.15A slow blow, replaceable Order D2-FUSE-1 (5 per pack)

<--->

See the Terminal Blocks and Wiring section in this catalog for part numbers of ZIPLink cables and terminal blocks compatible with this module.

Points
12 9 6 3 0 0 32

Derating Chart

250mA / Pt. P oints Yn+0 Yn+1 Yn+2 Yn+3 Yn+4 Yn+5 Yn+6 Yn+7

Addres s es Us ed P oints Us ed? Yes Yes Yes Yes Yes Yes No No Yn+10 Yn+11 Yn+12 Yn+13 Yn+14 Yn+15 Yn+16 Yn+17

Us ed? Yes Yes Yes Yes Yes Yes No No

300mA / Pt. OUT A 0 1 2 B 3 D2--12TA


15-132VAC 10mA-0.3A 50/60 Hz

18-110 VAC 4 5

10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F )

n is the starting address

15--132 VAC
L L L L L L 0

CA

4 1 5 2 NC 3 NC NC CB 0 4 1 5 2 NC 3

0 1 2 3

CA 4 5
Internal module circuitry OUTP UT Optical Is olator

15--132 VAC
L L L L L

0 1 2 3

CB 4 5

To LE D

COM 15--132 VAC 3.15A

NC

D2--12TA

492

PLC Products

1 - 80 0 - 633 - 0405

Relay Output Modules


D2-04TRS Relay Output
Outputs per Module Outputs Points Consumed Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current (resistive) Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
4 8 (only 1st 4pts. are used) 4 (isolated) Relay, form A (SPST) 5-30 VDC / 5-240 VAC 30 VDC, 264 VAC 0.72 VDC maximum 47 to 63 Hz 10 mA 4A/point; 8A/module (resistive) 0.1 mA @ 264 VAC 5A for < 10 ms 250 mA 10 ms 10 ms Removable; D2-8IOCON Logic side 2.8 oz. (80 g) 1 per point 6.3A slow blow, replaceable Order D2-FUSE-3 (5 per pack)

PLC Overview DL05/06 PLC

<---> Typical Relay Life (Operations)


Voltage & Load Current Type of Load 1A 2A 3A 4A

DL105 PLC DL205 PLC DL305 PLC DL405 PLC Field I/O Software C-more HMIs Other HMI AC Drives Motors Steppers/ Servos

24 VDC Resistive 500k 200k 100k 50k 24 VDC Solenoid 100k 40k 110 VAC Resistive 500k 250k 150k 100k 110 VAC Solenoid 200k 100k 50k 220 VAC Resistive 350k 150k 100k 50k 220 VAC Solenoid 100k 50k At 24 VDC, solenoid (inductive) loads over 2A cannot be used.
At 100 VAC, solenoid (inductive) loads over 3A cannot be used. At 220 VAC, solenoid (inductive) loads over 2A cannot be used.

Points
4 3 2 1 0

Derating Chart

Motor Controls

2A / Pt. 3A / Pt. 4A / Pt.

Proximity Sensors Photo Sensors Limit Switches Encoders

OUT 0 1 2 3 D2--04TR S
5-240VAC 4A50/60Hz 5-30VDC 10mA-4A

RELAY

0 32

10 50

20 30 40 68 86 104 Ambient Temperature (C/F )

50 55 C 122 131 F

Pushbuttons/ Lights Process Relays/ Timers Comm. TBs & Wiring

NC 5--30 VDC 5--240 VAC


L

NC C0 0 C1 1

NC NC C0 L C1 L C2 L C3 L 0
L

Internal module circuitry

Power
OUTP UT

Enclosures Appendix Part Index


6.3A

1 To LE D 2 COM 5--30 VDC 5--240 VAC

C2 2
L

C3 3
L

D2--04TR S

w w w. a u to m at i o n d i re c t . c o m / d l 205

PLC Products

493

Relay Output Modules


D2-08TR Relay Output
Outputs per Module Outputs Points Consumed Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current (resistive) Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
8 8 1 (2 I/O terminals) Relay, form A (SPST) 5-30 VDC; 5-240 VAC 30 VDC, 264 VAC N/A 47 to 60 Hz 5mA @ 5VDC 1A/point; 4A/common 0.1 mA @265 VAC Output: 3A for 10 ms Common: 10A for 10 ms 250 mA 12 ms 10 ms Removable; D2-8IOCON Logic side 3.9 oz. (110g) One 6.3A slow blow, replaceable Order D2-FUSE-3 (5 per pack)

<---> Typical Relay Life (Operations)


Voltage/Load
24 VDC Resistive 24 VDC Solenoid 110 VDC Resistive 110 VDC Solenoid 220 VAC Resistive 220 VAC Solenoid

Current
1A 1A 1A 1A 1A 1A

Closures
500k 100k 500k 200k 350k 100k

See the Terminal Blocks and Wiring section in this catalog for part numbers of ZIPLink cables and terminal blocks compatible with this module.

Points 8

Derating Chart

0.5A / Pt. OUT 0 1 2 3 D2--08TR


5-240VAC 1A50/60Hz 5-30VDC 5mA-1A

RELAY 4 5 6 7

6 4 1A / Pt. 2 0

5--30 VDC 5--240 VAC

C C 0

Internally connected

C C L 0 L 1 2 6 4 5

0 32

10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F )

L L L L

4 1 5 2

Internal module circuitry

OUTP UT
L

6
L L L

3 7

3 7

To LE D
D2--08TR

COM 5--30 VDC 5--240 VAC 6.3A

494

PLC Products

1 - 80 0 - 633 - 0405

Relay Output Modules


F2-08TRS Relay Output
Outputs per Module Outputs Points Consumed Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current (resistive) Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
8 8 8 (isolated) 3, Form C (SPDT) 5, Form A (SPST normally open) 7A @ 12-28 VDC, 12-250 VAC 0.5A @ 120VDC 150 VDC, 265 VAC N/A 47 to 63Hz 10mA @ 12 VDC 7A/point (subject to derating) N/A 12A 670 mA 15 ms (typical) 5ms (typical) Removable; D2-16IOCON Logic side 5.5oz. (156g) None
3

PLC Overview DL05/06 PLC

<---> Typical Relay Life1 (Operations) at Room Temperature


Voltage & Type of Load 2 Load Current 50mA 5A 7A

DL105 PLC DL205 PLC DL305 PLC DL405 PLC Field I/O Software C-more HMIs Other HMI AC Drives

24 VDC Resistive 10M 600k 300k 24 VDC Solenoid 150k 75k 110 VDC Resistive 600k 300k 110 VDC Solenoid 500k 200k 220 VAC Resistive 300k 150k 220 VAC Solenoid 250k 100k 1) Contact life may be extended beyond those values shown with the use of arc suppression techniques described in the DL205 User Manual. Since these modules have no leakage current, they do not have built-in snubber. For example, if you place a diode across a 24 VDC inductive load, you can significantly increase the life of the relay.
2) At 120 VDC 0.5A resistive load, contact life cycle is 200k cycles. 3) Normally closed contacts have 1/2 the current handling capability of the normally open contacts.
Derating Chart

8 6 Number Points On 4 (100% duty 2 cycle) 0 0 32 5A/pt.

4A/ pt.

Motors Steppers/ Servos

6A/ pt. 7A/pt.

Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Pushbuttons/ Lights

10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F )

OUT
NO 0

RELAY 4 5 6 7 Typical Circuit (points 1,2,3,4,5)


12--28VDC 12--250VAC
Common Internal Circuitry

12--28VDC 12--250VAC

C1 C0 NO 1

12--28VDC 12--250VAC

12--28VDC 12--250VAC

NC 0 normally clos ed L C2 C3 NO 2

0 1 2 3 F 2--08TR S
12-250VAC 7A50/60Hz 12-28VDC 10ma-7A C1 NO 0 C0 NC 0 C2 NO 2 C4 C3 NO 3 C5

Process Relays/ Timers Comm.

NO L

12--28VDC 12--250VAC

L NO 3

TBs & Wiring Power

12--28VDC 12--250VAC

C4 C5 NO 4

NO 1

12--28VDC 12--250VAC

Typical Circuit (P oints 0, 6, & 7 only)


12--28VDC 12--250VAC
Common Internal Circuitry

Enclosures Appendix Part Index

L NO 5 normally clos ed L NC 6 L

NO 4 NC 6 C6 NO 6 C7 NO7 NO 5 NC 7

12--28VDC 12--250VAC

C6

NC 7 normally clos ed L C7

12--28VDC 12--250VAC

L L

NO

NO 6 L NO 7 L

NC

w w w. a u to m at i o n d i re c t . c o m / d l 205

PLC Products

495

Relay Output Modules


F2-08TR Relay Output
Outputs per Module Outputs Points Consumed Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current
8 8 2 (isolated), 4-pts. per common 8, Form A (SPST normally open) 7A @ 12-28 VDC, 12-250VAC; 0.5A @ 120 VDC 150 VDC, 265 VAC N/A 47 to 63Hz 10 mA @ 12 VDC

<--->

Typical Relay Life1 (Operations) at Room Temperature


Voltage & Type of Load 2

50 mA

Load Current 5A 7A

24 VDC Resistive 10M 600k 300k 24 VDC Solenoid 150k 75k 110 VDC Resistive 600k 300k 110 VDC Solenoid 500k 200k 220 VAC Resistive 300k 150k 220 VAC Solenoid 250k 100k 1) Contact life may be extended beyond those values shown with the use of arc suppression techniques described in the DL205 User Manual. Since these modules have no leakage current, they do not have built-in snubber. For example, if you place a diode across a 24 VDC inductive load, you can significantly increase the life of the relay.
2) At 120 VDC 0.5A resistive load, contact life cycle is 200k cycles. 3) Normally closed contacts have 1/2 the current handling capability of the normally open contacts.

3 (subject to derating) Max Load Current (resistive) 10A/point Max of 10A/common

Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses

N/A 12A 670 mA 15 ms (typical) 5ms (typical) Removable; D2-8IOCON Logic side 5.5 oz. (156g) None

Derating Chart

8 6 Number Points On 4 (100% duty 2 cycle) 0 0 32 OUT 0 1 2 3 F 2--08TR


12-250VAC 10A50/60Hz 12-28VDC 10ma-10A

2.5 A/pt. 3 A/pt. 5A/pt. 10 A/pt.

10 20 30 40 50 55 C 50 68 86 104 122 131 F Ambient Temperature (C/F )

RELAY 4 5 6 7
12--28VDC 12--250VAC
Common

Typical Circuit

Internal Circuitry

L L NO 0 NO 1 C0-3 L L L L NO 2 NO 3 NO 4 NO 5 C4-7 L L NO 6 NO 7 L NO

496

PLC Products

1 - 80 0 - 633 - 0405

Relay Output Modules


D2-12TR Relay Output
Outputs per Module Outputs Points Consumed Commons per Module Output Type Operating Voltage Peak Voltage ON Voltage Drop AC Frequency Minimum Load Current Max Load Current (resistive) Max Leakage Current Max Inrush Current Base Power Required 5VDC OFF to ON Response ON to OFF Response Terminal Type (included) Status Indicator Weight Fuses
12 16 (four unused, see chart below) 2 (6-pts. per common) Relay, form A (SPST) 5-30 VDC; 5-240 VAC 30 VDC; 264 VAC N/A 47 to 60 Hz 5mA @ 5VDC 1.5 A/point; Max of 3A/common 0.1 mA @ 265 VAC Output: 3A for 10ms Common: 10A for 10ms 450 mA 10 ms 10 ms Removable; D2-16IOCON Logic side 4.6 oz. (130g) (2) 4A slow blow, replaceable Order D2-FUSE-4 (5 per pack)

PLC Overview

<--->

Typical Relay Life (Operations)


Voltage/Load
24 VDC Resistive 24 VDC Solenoid 110 VDC Resistive 110 VDC Solenoid 220 VAC Resistive 220 VAC Solenoid

DL05/06 PLC DL105 PLC DL205 PLC DL305 PLC DL405 PLC

Current
1A 1A 1A 1A 1A 1A

Closures
500k 100k 500k 200k 350k 100k

Addresses Used
Points
Yn+0 Yn+1 Yn+2 Yn+3 Yn+4 Yn+5 Yn+6 Yn+7

Field I/O

Used?
Yes Yes Yes Yes Yes Yes No No

Points
Yn+10 Yn+11 Yn+12 Yn+13 Yn+14 Yn+15 Yn+16 Yn+17 n is the starting address

Used?
Yes Yes Yes Yes Yes Yes No No

Software C-more HMIs Other HMI AC Drives Motors Steppers/ Servos Motor Controls Proximity Sensors

See the Terminal Blocks and Wiring section in this catalog for part numbers of ZIPLink cables and terminal blocks compatible with this module.

Points 12

Derating Chart

Photo Sensors Limit Switches

0.5A / Pt. OUT A 0 1 2 B 3 D2--12TR


CA 0 L L 1 L L L 2 NC 3 L NC NC CB 0 4 1 5 2 NC 3 L NC 5 4 5-240VAC 1.5A50/60Hz 5-30VDC 5mA-1.5A

RELAY 4 5

8 0.75A / Pt. 4 0 0 32 1.5A / Pt. 10 20 30 40 50 55 C 50 68 86 104 122131 F Ambient Temperature (C/F ) 1.25A / Pt.

Encoders Pushbuttons/ Lights Process Relays/ Timers

5--30 VDC 5--240 VAC

0 1 2 3 0 1 2 3

CA 4 5
L

Internal module circuitry OUTP UT

Comm. TBs & Wiring


To LE D

5--30 VDC 5--240 VAC


L L L L L

CB 4 5
5--30 VDC 5--240 VAC COM 4A

Power Enclosures Appendix Part Index

D2--12TR

w w w. a u to m at i o n d i re c t . c o m / d l 205

PLC Products

497

You might also like