Description
Overload protection trip class 10A
Phase loss sensitivity
Disconnect function
Temperature compensation from -25 +55 C
Adjustable current setting for overload protection
Suitable for three- and single-phase application
Trip-free mechanism
Clear switch position indication ON/OFF
Approvals
A
cULus UL 508
CB scheme
CCC
GOST-R
Marks
a
CE
GOST-F
ABS
Lloyds Register
RMRS
Bureau Veritas*
Order data
MS116 screw terminal
Setting
range
Type
Trip
Order code
class
Pack- Weight
ing unit per PCE
A
0.10...0.16 MS116-0.16 10A
1SAM250000R1001
PCE
1
kg
0.225
0.16...0.25
0.25...0.40
0.40...0.63
0.63...1.00
1.00...1.60
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
10A
10A
10A
10A
10A
1SAM250000R1002
1SAM250000R1003
1SAM250000R1004
1SAM250000R1005
1SAM250000R1006
1
1
1
1
1
0.225
0.225
0.225
0.225
0.265
1.60...2.50
2.50...4.00
4.00...6.30
6.30...10.0
8.00...12.0
10.0...16.0
16.0...20.0
20.0...25.0
25.0...32.0
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
10A
10A
10A
10A
10A
10A
10A
10A
10A
1SAM250000R1007
1SAM250000R1008
1SAM250000R1009
1SAM250000R1010
1SAM250000R1012
1SAM250000R1011
1SAM250000R1013
1SAM250000R1014
1SAM250000R1015
1
1
1
1
1
1
1
1
1
0.265
0.265
0.265
0.265
0.265
0.265
0.310
0.310
0.310
GL
DNV*
2CDC241001F0009
Functional description
1 Terminals 1L1, 3L2, 5L3
2 Test function
3 Current setting range
Adjustable current setting for overload protection
4 Terminals 2T1, 4T2, 6T3
2CDC241001F0009
2
3
4
Application
The manual motor starters protect the load and the installation against short-circuit and overload. They are three pole
protection devices with thermal tripping elements for overload protection and electromagnetic tripping elements for shortcircuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and
can be used for the manual switching of loads.
The manual motor starters have a setting scale in amperes, which allows the direct adjusting of the device without any
additional calculation. In compliance with international and national standards, the setting current is the rated current of the
motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current).
2CDC242024F0009
2CDC242023F0009
Operation mode
Single-phase operation
Three-phase operation
2CDC242025F0009
Wiring diagram
2 - 2CDC131025D0201
Setting range
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
lower value
A
0.10
0.16
0.25
0.40
0.63
1.00
1.60
2.50
4.00
6.30
8.00
10.0
16.0
20.0
25.0
66.00
25.50
10.38
4.36
1.605
0.648
0.272
0.106
0.046
0.024
0.016
0.011
0.0057
0.0045
0.0030
at upper value
W
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.4
2.3
2.8
2.3
2.8
3.1
Technical diagram
(Op/h)
140
100
ta =
0.5
80
60
ta = 5
s
40
60
duty ratio
80 100 (%)
2CDC232005F0211
20
20
1.5
s
3s
ta =
ta =
40
ta
switching frequency
120
2CDC131025D0201 - 3
Dimensions
in mm / inches
79,9 / 3,15"
80,1 / 3,15"
45 / 1,77"
2CDC242001F0011
57,8 / 2,3"
75 / 2,95"
27,5 / 1,1"
14 / 0,55"
45 / 1,77"
2CDC242003F0010
5,4 / 0,21"
17,5 / 0,69"
2CDC242002F0011
122 / 4,8"
9 / 0,35"
110 / 4,33"
4,5 / 0,18"
5,4 / 0,21"
110 / 4,33"
122 / 4,8"
9 / 0,35"
17,5 / 0,69"
4 - 2CDC131025D0201
14 / 0,55"
43,3 / 1,7"
MS116 20 A
MS116 16 A
4,5 / 0,18"
1,7 / 0,07"
97,8 / 3,85"
2CDC242002F0010
57,8 / 2,3"
45 / 1,77"
14 / 0,55"
45 / 1,77"
5,5 / 0,22"
1,5 / 0,06"
43,5 / 1,71"
35 / 1,38"
75 / 2,95"
27,5 / 1,1"
1,7 / 0,07"
90 / 3,54"
14 / 0,55"
69,8 / 2,75"
70 / 2,76"
5,5 / 0,22"
35 / 1,38"
1,5 / 0,06"
S1-M1-25
3-phase busbar
up to 65 A
PS1-..-65
3-phase busbar
up to 100 A
BS1-3
HK1
S1-M1-25
PS1-..-100
SK1
BS1-3
HK1
HK1
SK1
CK1
SA1
MS116
AA1
HK1
UA1
MS132
HKF1-11
1SBC500341F0000
CK1
2CDC131025D0201 - 5
up fuses on page 8
see table Order data on page 1
50/60 Hz
3
see table Resistance and power loss per pole on
Trip class
Rated frequency
Number of poles
Resistance per pole
Power loss per pole
page 3
Isolation data
Rated impulse withstand voltage Uimp
6 kV
690 V
Pollution degree
Electrical connection
Connecting capacity
MS116 16 A
MS116 20 A
solid
1/2 x 1 ... 4 mm
1/2 x 2.5 6 mm
stranded
1/2 x 1 ... 4 mm
1/2 x 2.5 6 mm
1/2 x 1 6 mm
1/2 x 1 6 mm
1/2 x 2.5 . 6 mm
Stripping length
9 mm
10 mm
Tightening torques
0.8 1.2 Nm
2 Nm
Connection screw
Type
Rated instantaneous
short-circuit current setting li
A
MS116-0.16
1.56
0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
2.44
3.90
6.14
11.50
18.40
28.75
50.00
78.75
150
180
240
300
375
480
0.25
0.40
0.63
1.0
1.6
2.5
4.0
6.3
10
12
16
20
25
32
6 - 2CDC131025D0201
General data
Mechanical durability
105
Electrical durability
10 x 104
Duty time
100%
Dimensions (W x H x D)
Weight
Mounting
Mounting positions
Group mounting
Minimum distance to other units same type
Minimum distance to electrical conductive board
Degree of protection
on request
horizontal
0 mm
vertical
150 mm
horizontal, up to 400 V
0 mm
horizontal, up to 690 V
> 1.5 mm
vertical
75 mm
enclosure / terminals
IP20
Utilization category
up to 2000 m
170 cycles/h
Electromagnetic compatibility
Electromagnetic compatibility
not applicable
Environmental data
Ambient air temperature
Operation
Storage
enclosed (IB132)
0 ... +40 C
-50 ... +80 C
continuous
5g / 3 ... 150 Hz
25g / 11 ms
Standards / directives
Product standard
IEC/EN 609472
IEC/EN 60947-4-1
IEC/EN 60947-1
UL 508, CSA 22.2 No. 14
2006/95/EC
EMC Directive
2004/108/EC
RoHS Directive
2002/95/EC
2CDC131025D0201 - 7
lCU
ICC
Note: Maximum rated current of the back-up fuses if ICC > ICS
Type
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
230 V AC
400 V AC
440 V AC
500 V AC
690 V AC
ICS
I CU
gG, aM I CS
I CU
gG, aM I CS
I CU
gG, aM I CS
I CU
gG, aM I CS
I CU
gG, aM
kA
kA
kA
kA
kA
kA
kA
kA
kA
kA
25
16
10
10
10
8 - 2CDC131025D0201
25
16
15
15
10
80
80
-
25
16
10
10
10
25
16
15
15
10
80
80
-
10
6
6
6
6
6
3
3
3
10
6
6
6
6
6
6
6
6
25
25
63
63
63
63
-
10
6
6
6
6
4
3
3
3
10
6
6
6
6
4
4
4
4
25
25
63
63
63
63
-
5
2
2
2
2
2
2
2
2
5
2
2
2
2
2
2
2
2
25
25
40
50
50
63
-
600 V
see table UL 508 Manual Motor Controller on page 10
Horse power
Electrical connection
Connecting capacity
MS116 16 A
MS116 20 A
stranded
Stripping length
9 mm
10 mm
Tightening torques
10 ... 12 lb-In
18 lb-In
Connection screw
M3.5 (Pozidrive 2)
M4 (Pozidrive 2)
Horse power
Type
220-240 VAC
FLA
hp
LRA
440-480 VAC
FLA
hp
LRA
MS116-0.16
0.16
0.96
0.16
0.96
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
0.25
0.4
0.63
1.0
1.5
2.4
3.78
6.0
0.25
0.4
0.63
1.0
1.5
2.4
3.78
6.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
1/10
1/6
1/3
1/2
1.5
2.2
3.6
4.9
1/2
1/2
1
1.6
2.5
2.5
4
9.6
-
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
1-1/2
2
2
3
3
5
2
3
5
5
7-1/2
10
6
8.5
14
14
21
26
10
12
12
17
17
28
92
127
162
81
116
145
Horse power
Type
hp
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
1/2
1
1-1/2
2
3
3
5
110-120 VAC
FLA
LRA
0.16
0.25
0.4
0.63
1.0
1.6
2.5
4.0
4.4
8.4
12
13.6
19.2
19.2
30.4
0.96
1.5
2.4
3.78
6.0
9.6
15.0
16.0
40
60
80
100
128
128
184
hp
1/2
1
1-1/2
3
3
5
5
7-1/2
10
220-240 VAC
FLA
LRA
0.16
0.25
0.4
0.63
1.0
1.6
2.2
4.2
6.4
9.6
9.6
15.2
15.2
22
28
0.96
1.5
2.4
3.78
6.0
9.6
20
30
40
64
64
92
92
127
162
hp
3/4
1
2
3
5
7-1/2
10
10
15
20
440-480 VAC
FLA
LRA
0.16
0.25
0.4
0.63
1.0
1.6
2.1
3.4
4.8
7.6
11
20
14
21
27
0.96
1.5
2.4
3.78
6.0
12.5
15
25
32
46
63.5
81
81
116
145
hp
1/2
3/4
1-1/2
3
5
7-1/2
10
10
15
20
25
500-600 VAC
FLA
LRA
0.16
0.25
0.4
0.63
0.9
1.3
2.4
3.9
6.1
9
11
11
17
22
27
0.96
1.5
2.4
3.78
8
10
16
25.6
36.8
50.8
64.8
64.8
93
116
146
2CDC131025D0201 - 9
1)
480 V
600 V
480 V
600 V
MS116-0.16
A
100
kA
30
kA
5
kA
18
kA
5
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
100
100
100
100
30
30
30
30
5
5
5
5
18
18
18
18
5
5
5
5
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
100
100
100
100
100
100
100
100
100
100
30
30
18
18
18
18
18
18
18
18
5
5
5
5
5
5
5
5
5
5
18
18
18
18
18
18
18
18
18
18
5
5
5
5
5
5
5
5
5
5
Suitable as motor disconnect only when provided with padlock SA1 or SA3...
10 - 2CDC131025D0201
Note:
We reserve the right to make technical changes
or modify the contents of this document without
prior notice. With regard to purchase orders, the
agreed particulars shall prevail. ABB AG does
not accept any responsibility whatsoever for
potential errors or possible lack of information in
this document.
We reserve all rights in this document and in
the subject matter and illustrations contained
therein. Any reproduction, disclosure to third
parties or utilization of its contents in whole
or in parts is forbidden without prior written
consent of ABB AG.
Copyright 2012 ABB
All rights reserved
Contact us