PLA 2.

5K-60-1000
Constant Voltage Mode
CVH Range CVM Range CVL Range Transient Time Range Fast Band(Default,Osc1) Slow Band(Osc2,Osc3) Temperature Coefficient CV Resolution*2 CVH Accuracy*2 CVM Accuracy*2 CVL Accuracy*2 CVH Resolution CVH Accuracy CVM Accuracy CCL Accuracy Program 0.000 ~ 60.00 0.000 ~ 30.00 0.000 ~ 6.000 V V V CPH Range CPM Range CPL Range 0.500 ~ 51.19 ms 0.500 ~ 511.9 ms 100 ppm / oC of Rated Voltage 1/16000 of Rated Voltage 0.05% 0.060 V 0.05% 0.060 V 0.05% 0.060 V 1/16000 of Rated Voltage 0.05% 0.060 V 0.05% 0.060 V 0.05% 0.060 V

2.5 kW
Constant Power Mode
0.000 0.000 @ Iin 0.000 @ Iin ~ ~ < ~ < 2,500 1,250 500.0 250.0 100.0 W W A W A

Transient Time Range Temperature Coefficient CP Resolution*2 CPH Accuracy*2 Program

Same As CC Mode 300 ppm / oC of Rated Power 1/16000 of Rated Power 1.00% 12.50 > 50.00 @Iin > 6.000 & Vin 1.00% 12.50 @Iin & Vin 1.00% @Iin & Vin 0.6000 @ Iin 0.0600 0.0006 W A V W A V W A V : A : :

CPM Accuracy*2

Display

> > > >


~ < ~ ~

CPL Accuracy*2

10.00 6.000 12.50 1.000 12.00 30.00 100.0 15.00 0.0600

Constant Current Mode


CCH Range CCM Range CCL Range Transient Time Range Fast Band(Default,Osc1) Slow Band(Osc2,Osc3) Minimum Voltage(IMax) Temperature Coefficient CC Resolution*2 CCH Accuracy*2 CCM Accuracy*2 CCL Accuracy*2 CC Resolution CCH Accuracy CCM Accuracy CCL Accuracy Program 0.000 ~ 1,000 0.000 ~ 500.0 0.000 ~ 100.0 0.050 ~ 51.19 0.500 ~ 511.9 0.600
o

Constant Resistance Mode


A A A ms ms V CRH Range CRM Range CRL Range Transient Time Range CRM / CRH CRL Temperature Coefficient

Same As CC Mode Same As CV Mode

100 ppm / C of Rated Current 1/16000 of Rated Current 0.05% 1.000 A 0.05% 1.000 A 0.05% 1.000 A Program 1/16000 of Rated Current 0.05% 1.000 A 0.05% 1.000 A 0.05% 1.000 A CRM / H CRL CR Resolution*2 CRH Accuracy*2 300 ppm / oC of Minimum Resistance 300 ppm / oC of Maximum Resistance 1/16000 Of Rated Value 1.00% 8.333 mS > 1.000 A @Iin & Vin 1.00% @Iin & Vin 1.00% @Iin & Vin

Display

> > > > >


CRM Accuracy*2

CRL Accuracy*2

Programmable Protection
Power(OPP) Range Resolution Accuracy Voltage(OVP) Range Resolution Accuracy Current(OCP) Range Resolution Accuracy Under Voltage Lockout(UVL) Mode Range Resolution Accuracy Anti-Oscillation 3.438 ~ 2,750 0.344 0.50% 6.875 0.039 ~ 63.00 0.004 0.20% 0.079 0.656 ~ 1,050 0.066 0.20% 1.313 W W W V V V A A A

12.00 33.33 10.00 6.000 0.060 100.0 0.060

V mS A V m: A V

External Programming Mode


Analog Program Accuracy Input Impedance BandWidth(-3dB) Monitor output Signal VMON Accuracy IMON Accuracy Transient Mode Frequency Range Accuracy Duty Range Accuracy Transient Time Accuracy Remote Interface 0~10 Volts Input yields 0~selected full scaled loading in all modes Same As Internal 0.1% Rating 400 k 1% Limited By Internal Transient Time 0~10 Volts output for 0~full scaled Value 0.10% 0.060 V 0.10% 1.000 A 10,000 Hz 0.1% 1.000 ~ 100.0 % 0.1% 10.0% 50% of Minimum Time GPIB / RS-232 / ETHERNET / USB 0.100 ~

Input On / Continuous 0.045 ~ 60.00 V 0.015 V 2.50% 0.075 V Default / Osc1 / Osc2 / Osc3 / Disable

Protection
Over Power Protection(OP) Over Voltage Protection(OV) Over Current Protection(OC) Over Temperature Protection(OTP) Reverse Maximum Current(RCP) Short Maximum Current Remote Inhibit(RI) Fault Indicator 2,750 63.00 1,100 90.00 1,100 52.38 1.200 10.48 5.000 W V A o C A A

General

Derating for higher temperatures

(-)1.67% Rated Power / oC

1,020 Short SPDT Relay (30Vdc/0.5A or 125Vac/0.25A)

Dielectric Strength
Primary Circuit To Chassis Primary Circuit To Load Terminal Load Terminal To Chassis 1500 Vac for 1 min 1500 Vac for 1 min 1500 Vdc for 1 min

AC Input Power Consumption Operating Temperature Dimension Weight Approx.Shipping Weight

95~240 Vac 48~62 Hz 130 VA 5 oC ~ 40 oC 24.5"(L)x17"(W)x5.25"(H) 70 lbs 108 lbs


Ver 4.1

31.8 kg 49.0 kg
Date : 11/01/07

*1 All Mode Specification measure by slow band and 25C room temperature unless otherwise specified *2 Transient Mode Specification must be x2 AMREL reserves the right to change limits,test conditions,and dimensions without notice

www.amrel.com Intl. 626 443-6818 U.S./Canada 800 654-9838

R&D-SPEC-PLA2.5K-60-1000

Rev.: 3

Page 1 of 2

PLA2.5K-60-1000 (60V,1000A,2.5KW) OPERATIONAL CURVE 100

10 VOLTAGE (V) 1 0.1 0.1 1 10 CURRENT (A) 100 1000

www.amrel.com Intl. 626 443-6818 U.S./Canada 800 654-9838

R&D-SPEC-PLA2.5K-60-1000

Rev.: 3

Page 2 of 2