You are on page 1of 6

CALCULATION FOR RC SLAB FALSEWORK SYSTEM

1. GENERAL
1.1 SCOPE OF WORK This calcula on is made to determine the false formwork for RC slab. 1.2 DESIGN CODE AND REFERENCES - Formwork - A Guide to Good Prac ce, Concrete Society - SNI - ACI 347 1.3 BASIC ASSUMPTION - Assume all loads are distributed uniformly. - Beam con nuous over three or more spans have value for moment, shear and deec on approximate by the formula shown in table. 1 1.4 DESIGN CRITERIA 1.4.1 Material and Allowable Stress - Dene Units Concrete Density Elas city of Wood Allowable stress of wood Allowable shear stress

: kN := 101.9716kg : cr := 2400
kg m
3

: Ewood := 100000 : wood := 100 : wood := 12


kg cm kg cm
2 2

kg cm
2

(class II)

(class II)

1.4.2 Other Requirement Data

2. DATA INFORMATION

CALCULATION FOR RC SLAB FALSEWORK SYSTEM

2. DATA INFORMATION
2.1 MATERIAL PROPERTIES 2.1.1 Shea ng Formwok - Plywood Thickness Width of Plywood

: tply := 19.mm : bply := 1 m (per 1 m' run)


bply tply 12 bply tply 6
2 3

Moment Iner a Plywood

: Iply := : Zply :=

= 57.158 cm

Sec on Modulus Plywood

= 60.167 cm

2.1.2 Joist - Timber Proper es

: bsupport2 := 50mm
hsupport2 := 100mm
3

Moment Iner a Timber

: Isupport2 := : Zsupport2 :=

bsupport2 hsupport2 12

= 416.667 cm
2

Sec on Modulus Timber

bsupport2 hsupport2 6

= 83.333 cm

2.1.3 Stringer Timber Proper es : bsupport1 := 100mm


hsupport1 := 100mm
3

Moment Iner a Timber

: Isupport1 := : Zsupport1 :=

bsupport1 hsupport1 12

= 833.333 cm
2

Sec on Modulus Timber

bsupport1 hsupport1 6

= 166.667 cm

2.1.4 Shores - Capacity of Scaold Frame 2.2 SLAB THICKNESS - Slab Thickness 2.3 FORMWORK ARRANGEMENT

: Rscaffold := 24.5kN

: tslab := 200.mm

2.3.1 Shea ng Formwork (Plywood) Plywood will be supported by 50x100 mm mber joist at every 600 mm span - Span for Plywood : Lply := 600mm 2.3.2 Joist (Timber 50x100 mm) Timber joist 50x100 mm will be supported on 100x100 mm mber stringer at 1219 mm span - Span for Support2 : Lsupport2 := 1219mm

CALCULATION FOR RC SLAB FALSEWORK SYSTEM

2.3.3 Stringer (Timber 100x100 mm)


The stringer supported by scaffold

Distance between Rows of scaold Distance between space of scaold

: Lrowscaffold := 1200mm : Lspacescaffold := 1500mm

3. LOADING DATA
Selfweight of RC Slab Construc on Load Selfweight of sots Total Load : Wslab := cr tslab = 480 : Wcons := 1.5 : Wfw := 0.5
kN
2

kg m
2

m kN m
2

: Wtot := Wslab + Wcons + W fw = 683.943

kg m
2

4. ANALYSIS
4.1 CAPACITY OF PLYWOOD 4.1.1 Load Act on Plywood Loading act for plywood dened as the total load act at formwork minus selfweight of sots
1 W ply := Wtot - W fw 1 m = 6.207 kN (per m' run) m

4.1.2 Check For Bending

Moment Resistance Plywood : Mres := wood Zply 0.675 = 0.398 kN m Max Bending Moment
Bending plywood := "OK"

: Mmax :=
if

Wply Lply 10

= 0.223 kN m (per m' run) Bending plywood = "OK"

Mmax 0.9 Mres otherwise

"Not OK"

4.1.3 Check for Shear

Shear Resistance Plywood Max Shear

: Vres := wood tply 1 m 0.25 = 5.59 kN

: Vmax := 0.6 Wply Lply = 2.235 kN (per m' run)


"OK" if Vmax 0.75 Vres otherwise Shearplywood = "OK"

Shearplywood :=

"Not OK"

CALCULATION FOR RC SLAB FALSEWORK SYSTEM

4.1.4 Check for Deec on

= 2.222 mm Allowable Deec on : all := 270

Lply

Max Deec on

: max :=
"OK"

W ply Lply

145 Ewood Iply if max all otherwise

= 0.99 mm

Deflection plywood :=

Deflection plywood = "OK"

"Not OK"

4.2 CAPACITY OF 50X100 TIMBER JOIST 4.2.1 Load Act on Timber Joist

Loading act at mber joist is the total load between joist span for 1 m strip
1 Wsupport2 := Wtot Lply = 4.024 kN (per m' run) m 4.2.2 Check for Bending

Moment Resistance Support2 : Mres2 := wood Zsupport2 = 0.817 kN m Max Bending Moment
Bending support2 := "OK"

: Mmax2 :=
if

W support2 Lsupport2 10

= 0.598 kN m

Mmax2 0.9 Mres2 otherwise

Bending support2 = "OK"

"Not OK" 4.2.3 Check for Shear

Shear Resistance Support2 Max Shear

: Vres2 := wood hsupport2 bsupport2 = 5.884 kN

: Vmax2 := 0.6 W support2 Lsupport2 = 2.943 kN


"OK" if Vmax2 0.75 Vres2 otherwise Shearsupport2 = "OK"

Shearsupport2 :=

"Not OK" 4.2.4 Check for Deec on

Allowable Deec on : all2 := Max Deec on

Lsupport2 270 1 145

= 4.515 mm
4

: max2 :=

W support2 Lsupport2 Ewood Isupport2

= 1.5 mm

CALCULATION FOR RC SLAB FALSEWORK SYSTEM

Deflection support2 :=

"OK"

if

max2 all2 otherwise

Deflection support2 = "OK"

"Not OK"

4.3 CAPACITY OF 100X100 TIMBER STRINGER

4.3.1 Load Act on Timber Stringer Load act on timber stringer is the total load at scaffold boundary Wsupport1 := Wtot

( Lrowscaffold + Lspacescaffold) L
2

rowscaffold = 10.866 kN

Max reac on at stringer : Rmax := 1.1 W support1 = 11.952 kN

4.3.2 Check for Bending

Moment Resistance Support1 : Mres1 := wood Zsupport1 = 1.634 kN m Max Bending Moment :
Mmax1 := 0.1 W support1 Lrowscaffold = 1.304 kN m

- Bendingsupport1 :=

"OK"

if

Mmax1 0.9 Mres1 otherwise

Bendingsupport1 = "OK"

"Not OK" 4.3.3 Check for Shear

Shear Resistance Support1 Max Shear

: Vres1 := wood hsupport1 bsupport1 = 11.768 kN

: Vmax1 := 0.6 W support1 = 6.519 kN


"OK" if Vmax1 0.75 Vres1 otherwise Shearsupport1 = "OK"

- Shearsupport1 :=

"Not OK" 4.3.4 Check for Deec on

Allowable Deec on : all1 :=

Lrowscaffold 270

= 4.444 mm

Max Deec on

: max1 := 0.00688
"OK" if

Wsupport1 Lrowscaffold Ewood Isupport1

1 m = 1.317 mm

Deflection support1 :=

max1 all1 otherwise

Deflection support1 = "OK"

"Not OK"

4.4 CAPACITY OF SCAFFOLD FRAME SHORES

CALCULATION FOR RC SLAB FALSEWORK SYSTEM

Capacity of Scaold Frame Rmax at stringer support

: Rscaffold := 24.5kN : Rmax = 11.952 kN

Capacity scaffold :=

"OK"

if

Rscaffold > Rmax otherwise

Capacity scaffold = "OK"

"Not OK"

5. DESIGN 6. ATTACHMENTS