You are on page 1of 29

3.

24

Section Three

3.6.9 NEC Section 240.12, System Coordination or Selectivity 3.6.9

(continued)

Overcurrent Protection

3.25

3.6.9

(Continued )

3.6.10 NEC Section 240.13, Ground-Fault Protection of Equipment on Buildings or Remote Structures 3.6.10

3.6.11 NEC Section 240.21, Location Requirements for Overcurrent Devices and Tap Conductors 3.6.11

(continued)

3.26

Section Three

3.6.11

(Continued )

(continued)

Overcurrent Protection

3.27

3.6.11

(Continued )

3.6.12 NEC Section 240.40, Disconnecting Means for Fuses 3.6.12

3.28

Section Three

3.6.13 NEC Section 240.50, Plug Fuses, Fuseholders, and Adapters 3.6.13

3.6.14 NEC Section 240.51, Edison-Base Fuses 3.6.14

3.6.15 NEC Section 240.53, Type S Fuses 3.6.15

Overcurrent Protection

3.29

3.6.16 NEC Section 240.54, Type S Fuses, Adapters, and Fuseholders 3.6.16

3.6.17 NEC Section 240.60, Cartridge Fuses and Fuseholders 3.6.17

3.6.18 NEC Section 240.61, Classification of Fuses and Fuseholders 3.6.18

3.30

Section Three

3.6.19 NEC Section 240.86, Series Ratings 3.6.19

3.6.20 NEC Section 240.90, Supervised Industrial Installations 3.6.20

Overcurrent Protection

3.31

3.6.21 NEC Section 240.92(B), Transformer Secondary Conductors of Separately Derived Systems (Supervised Industrial Installations Only) 3.6.21

3.6.22 NEC Section 240.92(B)(1), Short-Circuit and Ground-Fault Protection (Supervised Industrial Installations Only) 3.6.22

3.6.23 NEC Section 240.92(B)(2), Overload Protection (Supervised Industrial Installations Only) 3.6.23

3.6.24 NEC Section 240.92(C), Outside Feeder Taps (Supervised Industrial Installations Only) 3.6.24

3.32

Section Three

3.6.25 NEC Section 240.100, Feeder and BranchCircuit Protection over 600 V Nominal 3.6.25

3.6.26 NEC Section 240.100(C), Conductor Protection 3.6.26

3.7.1 NEC Section 250.2(D), Performance of Fault-Current Path 3.7.1

3.7.2 NEC Section 250.90, Bonding Requirements and Short-Circuit Current Rating 3.7.2

3.7.3 NEC Section 250.96(A), Bonding Other Enclosures and Short-Circuit Current Requirements 3.7.3

Overcurrent Protection

3.33

3.7.4 NEC Section 250.122, Sizing of Equipment Grounding Conductors 3.7.4

3.34

Section Three

3.8.1 NEC Section 310.10, Temperature Limitation of Conductors 3.8.1

3.9.1 NEC Section 364.11, Protection at a Busway Reduction 3.9.1

3.10.1 NEC Section 384.16, Panelboard Overcurrent Protection 3.10.1

Overcurrent Protection

3.35

3.11.1

NEC Section 430.1, Scope of Motor Article 3.11.1

3.11.2 NEC Section 430.6, Ampacity of Conductors for Motor Branch Circuits and Feeders 3.11.2

3.11.3

NEC Section 430.8, Marking on Controllers 3.11.3

3.36

Section Three

3.11.4 NEC Section 430.32, Motor Overload Protection 3.11.4

3.11.5 NEC Section 430.36, Fuses Used to Provide Overload and Single-Phasing Protection 3.11.5

Overcurrent Protection

3.37

3.11.6 NEC Section 430.52, Sizing of Various Overcurrent Devices for Motor Branch-Circuit Protection 3.11.6

3.38

Section Three

3.11.7 NEC Section 430.53, Connecting Several Motors or Loads on One Branch Circuit 3.11.7

3.11.8 NEC Section 430.71, Motor Control-Circuit Protection 3.11.8

Overcurrent Protection

3.39

3.11.9 NEC Section 430.72(A), Motor Control-Circuit Overcurrent Protection 3.11.9

3.11.10 NEC Section 430.72(B), Motor Control-Circuit Conductor Protection 3.11.10

(continued)

3.40

Section Three

3.11.10

(Continued )

Overcurrent Protection

3.41

3.11.11 NEC Section 430.72(C), Motor Control-Circuit Transformer Protection 3.11.11

3.42

Section Three

3.11.12 NEC Section 430.94, Motor Control-Center Protection 3.11.12

3.11.13 NEC Section 430.109(A)(6), Manual Motor Controller as a Motor Disconnect 3.11.13

3.12.1 NEC Section 440.5, Marking Requirements on HVAC Controllers 3.12.1

Overcurrent Protection

3.43

3.12.2 NEC Section 440.22, Application and Selection of the Branch-Circuit Protection for HVAC Equipment 3.12.2

3.13.1 NEC Section 450.3, Protection Requirements for Transformers 3.13.1

(continued)

3.44

Section Three

3.13.1

(Continued )

Overcurrent Protection

3.45

3.13.2 NEC Section 450.3(A), Protection Requirements for Transformers over 600 V 3.13.2

3.13.3 NEC Section 450.3(B), Protection Requirements for Transformers 600 V or Less 3.13.3

3.13.4 NEC Section 450.6(A)(3), Tie-Circuit Protection 3.13.4

3.46

Section Three

3.14.1 NEC Section 455.7, Overcurrent Protection Requirements for Phase Converters 3.14.1

3.15.1 NEC Section 460.8(B), Overcurrent Protection of Capacitors 3.15.1

3.16.1 NEC Section 501.6(B), Fuses for Class 1, Division 2 Locations 3.16.1

Overcurrent Protection

3.47

3.17.1 NEC Section 517.17, Requirements for Ground-Fault Protection and Coordination in Health Care Facilities 3.17.1

3.18.1 NEC Section 520.53(F)(2), Protection of Portable Switchboards on Stage 3.18.1

3.48

Section Three

3.19.1 NEC Section 550.6(B), Overcurrent Protection Requirements for Mobile Homes and Parks 3.19.1

3.20.1 NEC Section 610.14(C), Conductor Sizes and Protection for Cranes and Hoists 3.20.1

3.21.1 NEC Section 620.62, Selective Coordination of Overcurrent Protective Devices for Elevators 3.21.1

(continued)

Overcurrent Protection

3.49

3.21.1

(Continued )

3.22.1 NEC Section 670.3, Industrial Machinery 3.22.1

3.50

Section Three

3.23.1 NEC Section 700.5, Emergency Systems: Their Capacity and Rating 3.23.1

3.23.2 NEC Section 700.16, Emergency Illumination 3.23.2

Overcurrent Protection

3.51

3.23.3 NEC Section 700.25, Emergency System Overcurrent Protection Requirements (FPN) 3.23.3

3.24.1 NEC Section 705.16, Interconnected Electric Power Production Sources: Interrupting and Short-Circuit Current Rating 3.24.1

3.52

Section Three

3.25.1 NEC Section 725.23, Overcurrent Protection for Class 1 Circuits 3.25.1

3.26.1 NEC Section 760.23, Requirements for Non-Power-Limited Fire Alarm Signaling Circuits 3.26.1

You might also like