Professional Documents
Culture Documents
sameer raghuram
Registration No.:
Indresh rao
Registration No.:
MUKESH PATEL SCHOOL OF TECHNOLOGY MANAGEMENT & ENGINEERING Vile Parle (W), Mumbai-56
2012-13
CERTIFICATE
This is to certify that the minor project entitled Rescue and protection system for underground mine workers based on CC2500 , has been done by Mr. Aditya oza under my guidance and supervision for the third degree of Bachelor of Technology in Engineering in Electronics and Telecommunication of MPSTME, SVKMs NMIMS (Deemed-to-be University), Mumbai, India.
_______________________ Examiner
Acknowledgements
Abstract
This project addresses an economical, supple, continuous monitoring system of underground mine workers protection and security. A module of MEMS based sensors are used for monitoring underground parameters as per the requirement of the user and automating sequence of measuring data through digital wireless communication system is projected with high precision, soft control and reliability. A microcontroller based system is used for collecting and storing data and making decision accordingly, based on which the mine worker is informed through different alarm tone. The communication system is reliable based on CC2500 RF module, IEEE 802.15.4 standard. This is used for transmission between the hardware circuit fitted with the mine workers and the ground control centre computer system through some routers.
Page 4
Page 5
LIST OF TABLES
Table 1.1: Hardware Components.....3
Page 6
Page 7
Page 8
Page 9
3.1
Hardware Setup
Hardware circuit that will be attached with the body of the mine workers. This may be preferably fitted with the safety helmet of the workers also which should be mandatory in the premises of any underground mines. An additional stand by system can be fitted with the wrist of the underground mine workers if required. The circuit has a sensor module consisting of some MEMS based sensors that measures real-time underground parameters like temperature, humidity concentration of different gases, vibration inside mines etc. Gas concentration is meant for the harmful gases like methane and carbon-monoxide etc. Some of the gases are toxic and some are inflammable. A microcontroller is used with the sensors to receive the sensor outputs and to take the necessary decision. The microcontroller can store datas as required by the user for m aintaining of records. Once temperature is more than the safety level preprogrammed at microcontroller, microcontroller decodes beep alarms through the headset speaker connected with controller as shown in Fig. 1. Again, once the measured humidity value is more than the safety level preprogrammed at microcontroller, it decodes different type of beep alarms. Similarly when gas concentration crosses the safety level, microcontroller decodes siren alarms. In all such cases, this will send an alarm through an urgent message and alarm sound to the ground control terminal through CC2500. The microcontroller data is transmitted through two separate boards i.e. CC2500 transmission module to the data collector or receiver module. The microcontroller used here is Atmega 8 with 12MHz operating frequency. It has four I/O ports, seven A/D input channels and 368 bytes data memory.
Diagram
As shown in Fig. 2, the data receiving terminal of CC2500 RX and data transmitting terminal TX are cross connected to the microcontroller corresponding transmitter and receiver terminals TxD and RxD respectively. After installing necessary software. The RESET pin of Zigbee is used to provide an optional reset facility of user through a reset button. A transistor is used for this purpose.The XBee Modules used in the interfacing boards, are engineered to meet IEEE 802.15.4 standards. It is lowcost, low power, reliable 20 pin device that operates within the ISM 2.4 GHz frequency band. It has 30 to 100 meter data transmission capability with rate of 250,000 bps. XBee modules operate in five modes. When not receiving or transmitting data, the RF module is in Idle Mode. The RF module shifts into the other modes of operation under various conditions. In transmit mode serial data is received in the DI (data in) buffer and the data is stored in the DI Buffer until it can be processed. When the DI buffer is 17 bytes away from being full, by default, the module de-asserts CTS (high) to signal to the host device to stop sending data (as shown in Fig. 2). CTS is re-asserted after the DI
Page 10
Page 11
Page 12
5.2 Disadvantage
System is costly System fails if come in content of water (can be made water resistance but it increase further cost of system)
Page 13
Page 14
Page 15