You are on page 1of 24

Plan_Checker7v3

By Dayanti Pratiwi

Was developed under:


Windows XP MapInfo/MapBasic 7

Necessary header/column for bts table:


BTS_NAME CI X: Longitude Y: Latitude CELL_TYPE: Macro, Micro, Indoor CELL_SYST: DCS, GSM NUM_SECT: #of sector 1 for single cell, > 1 for quasi antennas AZM1 to AZM4 (azimuth) -2 for indoor (small square) -1 for omni antenna (circle) If single cell just use AZM1 and others put 0 NCC BCC BCCH TCH1 to TCH7: put 0 if not use SIZE (optional): in meter

Necessary header/column for adjacency table (using BTS_NAME format):


SOURCE TARGET
Company Confidential
1 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Plan_Checker7v3
By Dayanti Pratiwi

No need to create specific directory nor specific table name Flexibility format data txt/xls/mdb for input table Capable for Frequency Checker; Handover Checker; BSIC Checker; KPI Checker Additional menu for neighbor audit
Delete/Create HO, the list of deleted/created relation will be recorded in tabnameAudit.TAB

Mapping the KPI from different table and create the thematic on the map Three different style of drawing the btstable for your presentation purposes Connect the measurement data with related cell using Line Connection

Note: Please exit the tools and run again if you found problem cannot draw the btstable, this is bugs from MapInfo7, I cannot fix it
Company Confidential
2 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential
3 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Clover2 style The DCS and GSM data will be split into two different table

Arrow style

Indoor

Micro

Clover1 style using user defined from column SIZE value

Clover1 style The DCS and GSM data keep maintain in one table Macro GSM Company Confidential
4 2005 Nokia

SIZE = 100

Macro DCS

Size = 300

Plan_Checker7v2.ppt / 2005-10-25 / DP

Select the coordinate column with XY; and the projection that you use Default projection is Longitude/Latitude in decimal degree

Follow the instruction on the dialog

Flexible for any data type (txt/xls/mdb) The simplest one is txt format, minimize your mistakes if you forgot to put 0 value when no data Company Confidential
5 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Quasi omni with 4 antennas direction

indoor

Company Confidential
6 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Put 0 value if you have no data

Necessary columns are SOURCE & TARGET, the other columns are your own additional data

Company Confidential
7 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

You need to open the btstable first before continue with the checker menus

Company Confidential
8 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Frequency Checker Menus: Open window frequency checker and then select the freq that you want to check

Company Confidential
9 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

New freq will be checked

Red = co = ch55 Blue = co + 1 = ch56 Green = co 1 = ch54

Company Confidential
10 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Handover Checker Menus: Open window HO checker; Open HO table; and then select the relation that you want to check

Company Confidential
11 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

New HO will be checked

Red = selected bts / SOURCE Blue = adjacencies bts / TARGET

Company Confidential
12 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Select the bts that you want to add in your neighbor list; and then choose menu Create HO

Company Confidential
13 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

After Ctr+j you will see that the new neighbors were added

Company Confidential
14 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Select the bts that you want to delete in your neighbor list; and then choose menu Delete HO

Company Confidential
15 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

After Ctr+j you will see that the old neighbors were deleted

Company Confidential
16 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Your delete/create list result will be saved in the new tableAudit.TAB in the same directory with your other data

When you delete the adjacency from the HO list there will be blank rows in the adce table, you can Packing the HO Table to clean up the blank rows after you finished the neighbor audit

Company Confidential
17 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

BSIC Checker Menus: Open window BSIC checker and then select the BSIC or co BCCH_BSIC that you want to check

Company Confidential
18 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Check BSIC only, if you want to check co BCCH_BSIC choose menu

Company Confidential
19 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

KPI Checker Menus: Open window KPI checker; Open KPI table; and then select the column kpi that you want to display

Company Confidential
20 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Column from KPI table that you want to display will be inserted temporarily into BTS table

If you want to modify the previous threshold and redraw the result Open KPI table You can use any data and no need to create specific table/columns name

Company Confidential
21 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Line Connection Menus: Open window Line Connection; Open measurement table (TAB format); and then draw the line connection between bts vs measurement point using CI as reference

Company Confidential
22 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

You can use any measurement data (TOM ; TEMS ; etc) as long as you have CI column with integer type in your TAB table

The result will be saved in measnameLine.TAB in the same directory

Company Confidential
23 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Note: we are using dummy data for the sample

Have a nice day

Company Confidential
24 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

You might also like