A thermal power station is a power plant in which the prime mover is steam driven. Water is heated, turns into
steam and spins a steam turbine which drives an electrical generator. After it passes through the turbine, the
steam is condensed in a condenser; this is known as a Rankine cycle. The greatest variation in the design of
thermal power stations is due to the different fuel sources. Some prefer to use the term energy center because
such facilities convert forms of heat energy into electrical energy. However, power plant is the most common
term in the United States, while power station prevails in many Commonwealth countries and especially in the
United Kingdom.
Almost all coal, nuclear, geothermal, solar thermal electric, and waste incineration plants, as well as many
natural gas power plants are thermal. Natural gas is frequently combusted in gas turbines as well as boilers. The
waste heat from a gas turbine can be used to raise steam, in a combined cycle plant that improves overall
efficiency.Such power stations are most usually constructed on a very large scale and designed for continuous
operation.
History
Reciprocating steam engines have been used for mechanical power sources since the 18th Century, with notable
improvements being made by James Watt. The very first commercial central electrical generating stations in
New York and London, in 1882, also used reciprocating steam engines. As generator sizes increased, eventually
turbines took over due to higher efficiency and lower cost of construction. By the 1920s any central station
larger than a few thousand kilowatts would use a turbine prime mover.
Efficiency
The electric efficiency of a conventional thermal power station, considered as saleable energy produced at the
plant busbars compared with the heating value of the fuel consumed, is typically 33 to 48% efficient, limited as
all heat engines are by the laws of thermodynamics (See: Carnot cycle). The rest of the energy must leave the
plant in the form of heat. This waste heat can be disposed of with cooling water or in cooling towers. If the
waste heat is instead utilized for e.g. district heating, it is called cogeneration. An important class of thermal
power station are associated with desalination facilities; these are typically found in desert countries with large
supplies of natural gas and in these plants, freshwater production and electricity are equally important co-
products.
Since the efficiency of the plant is fundamentally limited by the ratio of the absolute temperatures of the steam
at turbine input and output, efficiency improvements require use of higher temperature, and therefore higher
pressure, steam. Historically, other working fluids such as mercury have been experimentally used in a mercury
vapour turbine power plant, since these can attain higher temperatures than water at lower working pressures.
However, the obvious hazards of toxicity, and poor heat transfer properties, have ruled out mercury as a
working fluid.
Diagram of a typical coal-fired thermal power station
Steam generator
Schematic diagram of typical coal-fired power plant steam generator highlighting the air preheater (APH)
location. (For simplicity, any radiant section tubing is not shown.)
The steam generating boiler has to produce steam at the high purity, pressure and temperature required for the
steam turbine that drives the electrical generator. The generator includes the economizer, the steam drum, the
chemical dosing equipment, and the furnace with its steam generating tubes and the superheater coils.
Necessary safety valves are located at suitable points to avoid excessive boiler pressure. The air and flue gas
path equipment include: forced draft (FD) fan, air preheater (APH), boiler furnace, induced draft (ID) fan, fly
ash collectors (electrostatic precipitator or baghouse) and the flue gas stack.[1][2][3]
For units over about 200 MW capacity, redundancy of key components is provided by installing duplicates of
the FD fan, APH, fly ash collectors and ID fan with isolating dampers. On some units of about 60 MW, two
boilers per unit may instead be provided.
Boiler furnace and steam drum
Once water inside the boiler or steam generator, the process of adding the latent heat of vaporization or enthalpy
is underway. The boiler transfers energy to the water by the chemical reaction of burning some type of fuel.
The water enters the boiler through a section in the convection pass called the economizer. From the
economizer it passes to the steam drum. Once the water enters the steam drum it goes down the downcomers to
the lower inlet waterwall headers. From the inlet headers the water rises through the waterwalls and is
eventually turned into steam due to the heat being generated by the burners located on the front and rear
waterwalls (typically). As the water is turned into steam/vapor in the waterwalls, the steam/vapor once again
enters the steam drum. The steam/vapor is passed through a series of steam and water separators and then dryers
inside the steam drum. The steam separators and dryers remove the water droplets from the steam and the cycle
through the waterwalls is repeated. This process is known as natural circulation.
The boiler furnace auxiliary equipment includes coal feed nozzles and igniter guns, soot blowers, water lancing
and observation ports (in the furnace walls) for observation of the furnace interior. Furnace explosions due to
any accumulation of combustible gases after a trip-out are avoided by flushing out such gases from the
combustion zone before igniting the coal.
The steam drum (as well as the superheater coils and headers) have air vents and drains needed for initial
startup. The steam drum has internal devices that removes moisture from the wet steam entering the drum from
the steam generating tubes. The dry steam then flows into the superheater coils.
Geothermal plants need no boiler since they use naturally occurring steam sources. Heat exchangers may be
used where the geothermal steam is very corrosive or contains excessive suspended solids. Nuclear plants also
boil water to raise steam, either directly passing the working steam through the reactor or else using an
intermediate heat exchanger.
Fuel preparation system
In coal-fired power stations, the raw feed coal from the coal storage area is first crushed into small pieces and
then conveyed to the coal feed hoppers at the boilers. The coal is next pulverized into a very fine powder. The
pulverizers may be ball mills, rotating drum grinders, or other types of grinders.
Some power stations burn fuel oil rather than coal. The oil must kept warm (above its pour point) in the fuel oil
storage tanks to prevent the oil from congealing and becoming unpumpable. The oil is usually heated to about
100°C before being pumped through the furnace fuel oil spray nozzles.
Boilers in some power stations use processed natural gas as their main fuel. Other power stations may use
processed natural gas as auxiliary fuel in the event that their main fuel supply (coal or oil) is interrupted. In such
cases, separate gas burners are provided on the boiler furnaces.
Fuel firing system and igniter system
From the pulverized coal bin, coal is blown by hot air through the furnace coal burners at an angle which
imparts a swirling motion to the powdered coal to enhance mixing of the coal powder with the incoming
preheated combustion air and thus to enhance the combustion.
To provide sufficient combustion temperature in the furnace before igniting the powdered coal, the furnace
temperature is raised by first burning some light fuel oil or processed natural gas (by
Air path
External fans are provided to give sufficient air for combustion. The forced draft fan takes air from the
atmosphere and, first warming it in the air preheater for better combustion, injects it via the air nozzles on the
furnace wall.
The induced draft fan assists the FD fan by drawing out combustible gases from the furnace, maintaining a
slightly negative pressure in the furnace to avoid backfiring through any opening. At the furnace outlet, and
before the furnace gases are handled by the ID fan, fine dust carried by the outlet gases is removed to avoid
atmospheric pollution. This is an environmental limitation prescribed by law, and additionally minimizes
erosion of the ID fan.
Auxiliary systems
Fly ash collection
Fly ash is captured and removed from the flue gas by electrostatic precipitators or fabric bag filters (or
sometimes both) located at the outlet of the furnace and before the induced draft fan. The fly ash is periodically
removed from the collection hoppers below the precipitators or bag filters. Generally, the fly ash is
pneumatically transported to storage silos for subsequent transport by trucks or railroad cars.
Bottom ash collection and disposal
At the bottom of every boiler, a hopper has been provided for collection of the bottom ash from the bottom of
the furnace. This hopper is always filled with water to quench the ash and clinkers falling down from the
furnace. Some arrangement is included to crush the clinkers and for conveying the crushed clinkers and bottom
ash to a storage site.
Boiler make-up water treatment plant and storage
Since there is continuous withdrawal of steam and continuous return of condensate to the boiler, losses due to
blow-down and leakages have to be made up for so as to maintain the desired water level in the boiler steam
drum. For this, continuous make-up water is added to the boiler water system. The impurities in the raw water
input to the plant generally consist of calcium and magnesium salts which impart hardness to the water.
Hardness in the make-up water to the boiler will form deposits on the tube water surfaces which will lead to
overheating and failure of the tubes. Thus, the salts have to be removed from the water and that is done by a
water demineralising treatment plant (DM). A DM plant generally consists of cation, anion and mixed bed
exchangers. The final water from this process consists essentially of hydrogen ions and hydroxide ions which is
the chemical composition of pure water. The DM water, being very pure, becomes highly corrosive once it
absorbs oxygen from the atmosphere because of its very high affinity for oxygen absorption.
The capacity of the DM plant is dictated by the type and quantity of salts in the raw water input. However, some
storage is essential as the DM plant may be down for maintenance. For this purpose, a storage tank is installed
from which DM water is continuously withdrawn for boiler make-up. The storage tank for DM water is made
from materials not affected by corrosive water, such as PVC. The piping and valves are generally of stainless
steel. Sometimes, a steam blanketing arrangement or stainless steel doughnut float is provided on top of the
water in the tank to avoid contact with atmospheric air. DM water make-up is generally added at the steam
space of the surface condenser (i.e., the vacuum side). This arrangement not only sprays the water but also DM
water gets deaerated, with the dissolved gases being removed by the ejector of the condenser itself.
Steam turbine-driven electric generator
The steam turbine-driven generators have auxiliary systems enabling them to work satisfactorily and safely. The
steam turbine generator being rotating equipment generally has a heavy, large diameter shaft. The shaft
therefore requires not only supports but also has to be kept in position while running. To minimise the frictional
resistance to the rotation, the shaft has a number of bearings. The bearing shells, in which the shaft rotates, are
lined with a low friction material like Babbitt metal. Oil lubrication is provided to further reduce the friction
between shaft and bearing surface and to limit the heat generated.
Barring gear
Barring gear (or "turning gear") is the mechanism provided to rotate the turbine generator shaft at a very low
speed after unit stoppages. Once the unit is "tripped" (i.e., the steam inlet valve is closed), the turbine coasts
down towards standstill. When it stops completely, there is a tendency for the turbine shaft to deflect or bend if
allowed to remain in one position too long. This is because the heat inside the turbine casing tends to
concentrate in the top half of the casing, making the top half portion of the shaft hotter than the bottom half. The
shaft therefore could warp or bend by millionths of inches.
This small shaft deflection, only detectable by eccentricity meters, would be enough to cause damaging
vibrations to the entire steam turbine generator unit when it is restarted. The shaft is therefore automatically
turned at low speed (about one revolution per minute) by the barring gear until it has cooled sufficiently to
permit a complete stop.
Condenser
Feedwater heater
A Rankine cycle with a two-stage steam turbine and a single feedwater heater.
In the case of a conventional steam-electric power plant utilizing a drum boiler, the surface condenser removes
the latent heat of vaporization from the steam as it changes states from vapour to liquid. The heat content (btu)
in the steam is referred to as Enthalpy. The condensate pump then pumps the condensate water through a
feedwater heater. The feedwater heating equipment then raises the temperature of the water by utilizing
extraction steam from various stages of the turbine.[2][3]
Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the
thermodynamic efficiency of the system.[9] This reduces plant operating costs and also helps to avoid thermal
shock to the boiler metal when the feedwater is introduced back into the steam cycle.
Superheater
As the steam is conditioned by the drying equipment inside the drum, it is piped from the upper drum area into
an elaborate set up of tubing in different areas of the boiler. The areas known as superheater and reheater. The
steam vapor picks up energy and its temperature is now superheated above the saturation temperature. The
superheated steam is then piped through the main steam lines to the valves of the high pressure turbine.
Deaerator
Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage
section
A steam generating boiler requires that the boiler feed water should be devoid of air and other dissolved gases,
particularly corrosive ones, in order to avoid corrosion of the metal.
Generally, power stations use a deaerator to provide for the removal of air and other dissolved gases from the
boiler feedwater. A deaerator typically includes a vertical, domed deaeration section mounted on top of a
horizontal cylindrical vessel which serves as the deaerated boiler feedwater storage tank.[2][3][10]
There are many different designs for a deaerator and the designs will vary from one manufacturer to another.
The adjacent diagram depicts a typical conventional trayed deaerator.[10][11] If operated properly, most deaerator
manufacturers will guarantee that oxygen in the deaerated water will not exceed 7 ppb by weight (0.005
cm³/L).[10][12]
Auxiliary systems
Oil system
An auxiliary oil system pump is used to supply oil at the start-up of the steam turbine generator. It supplies the
hydraulic oil system required for steam turbine's main inlet steam stop valve, the governing control valves, the
bearing and seal oil systems, the relevant hydraulic relays and other mechanisms.
At a preset speed of the turbine during start-ups, a pump driven by the turbine main shaft takes over the
functions of the auxiliary system.
Generator heat dissipation
The electricity generator requires cooling to dissipate the heat that it generates. While small units may be cooled
by air drawn through filters at the inlet, larger units generally require special cooling arrangements. Hydrogen
gas cooling, in an oil-sealed casing, is used because it has the highest known heat transfer coefficient of any gas
and for its low viscosity which reduces windage losses. This system requires special handling during start-up,
with air in the chamber first displaced by carbon dioxide before filling with hydrogen. This ensures that the
highly flammable hydrogen does not mix with oxygen in the air.
The hydrogen pressure inside the casing is maintained slightly higher than atmospheric pressure to avoid
outside air ingress. The hydrogen must be sealed against outward leakage where the shaft emerges from the
casing. Mechanical seals around the shaft are installed with a very small annular gap to avoid rubbing between
the shaft and the seals. Seal oil is used to prevent the hydrogen gas leakage to atmosphere.
The generator also uses water cooling. Since the generator coils are at a potential of about 22 kV and water is
conductive, an insulating barrier such as Teflon is used to interconnect the water line and the generator high
voltage windings. Demineralized water of low conductivity is used.
Generator high voltage system
The generator voltage ranges from 11 kV in smaller units to 22 kV in larger units. The generator high voltage
leads are normally large aluminum channels because of their high current as compared to the cables used in
smaller machines. They are enclosed in well-grounded aluminum bus ducts and are supported on suitable
insulators. The generator high voltage channels are connected to step-up transformers for connecting to a high
voltage electrical substation (of the order of 110 kV or 220 kV) for further transmission by the local power grid.
The necessary protection and metering devices are included for the high voltage leads. Thus, the steam turbine
generator and the transformer form one unit. In smaller units, generating at 11 kV, a breaker is provided to
connect it to a common 11 kV bus system.
Other systems
Monitoring and alarm system
Most of the power plant operational controls are automatic. However, at times, manual intervention may be
required. Thus, the plant is provided with monitors and alarm systems that alert the plant operators when certain
operating parameters are seriously deviating from their normal range.
Battery supplied emergency lighting and communication
A central battery system consisting of lead acid cell units is provided to supply emergency electric power, when
needed, to essential items such as the power plant's control systems, communication systems, turbine lube oil
pumps, and emergency lighting. This is essential for a safe, damage-free shutdown of the units in an emergency
situation.
Application
Boilers have many applications. They can be used in stationary applications to provide heat, hot water, or steam
for domestic use, or in generators and they can be used in mobile applications to provide steam for locomotion
in applications such as trains, ships, and boats. Using a boiler is a way to transfer stored energy from the fuel
source to the water in the boiler, and then finally to the point of end use.
Materials
Construction of boilers is mainly in steel, stainless steel, and wrought iron. In live steam models, copper or
brass is often used. Historically copper was often used for fireboxes (particularly for steam locomotives),
because of its better thermal conductivity. The price of copper now makes this impractical.
Cast iron is used for domestic water heaters. Although these are usually termed "boilers", their purpose is to
produce hot water, not steam, and so they run at low pressure and try to avoid actual boiling. The brittleness of
cast iron makes it impractical for steam pressure vessels.
For much of the Victorian "age of steam", the only material for boilermaking was the highest grade of wrought
iron, with assembly by rivetting. This iron was often obtained from specialist ironworks, such as Cleator Moor
(UK), noted for the high quality of their rolled plate and its suitability for high reliability use in critical
applications, such as high pressure boilers. 20th century practice moved towards steel and welding.
Fuel
The source of heat for a boiler is combustion of any of several fuels, such as wood, coal, oil, or natural gas.
Electric steam boilers use resistance or immersion type heating elements. Nuclear fission is also used as a heat
source for generating steam. Heat recovery steam generators (HRSGs) use the heat rejected from other
processes such as gas turbines.
Configurations
Boilers can be classified into the following configurations:
• "Pot boiler" or "Haycock boiler": a primitive "kettle" where a fire heats a partially-filled water container
from below. 18th Century Haycock boilers generally produced and stored large volumes of very low-
pressure steam, often hardly above that of the atmosphere. These could burn wood or most often, coal.
Efficiency was very low.
• Fire-tube boiler. Here, water partially fills a boiler barrel with a small volume left above to
accommodate the steam (steam space). This is the type of boiler used in nearly all steam locomotives.
The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in
order to maintain the temperature of the heating surface just below boiling point. The furnace can be
situated at one end of a fire-tube which lengthens the path of the hot gases, thus augmenting the heating
surface which can be further increased by making the gases reverse direction through a second parallel
tube or a bundle of multiple tubes (two-pass or return flue boiler); alternatively the gases may be taken
along the sides and then beneath the boiler through flues (3-pass boiler). In the case of a locomotive-type
boiler, a boiler barrel extends from the firebox and the hot gases pass through a bundle of fire tubes
inside the barrel which greatly increase the heating surface compared to a single tube and further
improve heat transfer. Fire-tube boilers usually have a comparatively low rate of steam production, but
high steam storage capacity. Fire-tube boilers mostly burn solid fuels, but are readily adaptable to those
of the liquid or gas variety.
• Water-tube boiler. In this type,the water tubes are arranged inside a furnace in a number of possible
configurations: often the water tubes connect large drums, the lower ones containing water and the upper
ones, steam; in other cases, such as a monotube boiler, water is circulated by a pump through a
succession of coils. This type generally gives high steam production rates, but less storage capacity than
the above. Water tube boilers can be designed to exploit any heat source including nuclear fission and
are generally preferred in high pressure applications since the high pressure water/steam is contained
within narrow pipes which can withstand the pressure with a thinner wall.
Type of boilers
Safety
Historically, boilers were a source of many serious injuries and property destruction due to poorly understood
engineering principles. Thin and brittle metal shells can rupture, while poorly welded or riveted seams could
open up, leading to a violent eruption of the pressurized steam. Collapsed or dislodged boiler tubes could also
spray scalding-hot steam and smoke out of the air intake and firing chute, injuring the firemen that loaded coal
into the fire chamber. Extremely large boilers providing hundreds of horsepower to operate factories could
demolish entire buildings.[4]
A boiler that has a loss of feed water and is permitted to boil dry can be extremely dangerous. If feed water is
then sent into the empty boiler, the small cascade of incoming water instantly boils on contact with the
superheated metal shell and leads to a violent explosion that cannot be controlled even by safety steam valves.
Draining of the boiler could also occur if a leak occurred in the steam supply lines that was larger than the
make-up water supply could replace. The Hartford Loop was invented in 1919 by the Hartford Steam Boiler and
Insurance Company as a method to help prevent this condition from occurring, and thereby reduce their
insurance claims.[5]
Superheated steam boilers
Controlling draft
Most boilers now depend on mechanical draft equipment rather than natural draft. This is because natural draft
is subject to outside air conditions and temperature of flue gases leaving the furnace, as well as the chimney
height. All these factors make proper draft hard to attain and therefore make mechanical draft equipment much
more economical.
There are three types of mechanical draft:
• Induced draft: This is obtained one of three ways, the first being the "stack effect" of a heated chimney,
in which the flue gas is less dense than the ambient air surrounding the boiler. The denser column of
ambient air forces combustion air into and through the boiler. The second method is through use of a
steam jet. The steam jet oriented in the direction of flue gas flow induces flue gasses into the stack and
allows for a greater flue gas velocity increasing the overall draft in the furnace. This method was
common on steam driven locomotives which could not have tall chimneys. The third method is by
simply using an induced draft fan (ID fan) which sucks flue gases out of the furnace and up the stack.
Almost all induced draft furnaces have a negative pressure.
• Forced draft: Draft is obtained by forcing air into the furnace by means of a fan (FD fan) and ductwork.
Air is often passed through an air heater; which, as the name suggests, heats the air going into the
furnace in order to increase the overall efficiency of the boiler. Dampers are used to control the quantity
of air admitted to the furnace. Forced draft furnaces usually have a positive pressure.
• Balanced draft: Balanced draft is obtained through use of both induced and forced draft. This is more
common with larger boilers where the flue gases have to travel a long distance through many boiler
passes. The induced draft fan works in conjunction with the forced draft fan allowing the furnace
pressure to be maintained slightly below atmospheric.
Scrubber systems are a diverse group of air pollution control devices that can be used to remove some
particulates and/or gases from industrial exhaust streams. Traditionally, the term "scrubber" has referred to
pollution control devices that used liquid to "scrub" unwanted pollutants from a gas stream. Recently, the term
is also used to describe systems that inject a dry reagent or slurry into a dirty exhaust stream to "scrub out" acid
gases. Scrubbers are one of the primary devices that control gaseous emissions, especially acid gases.
•
Removal and neutralization
The exhaust gases of combustion may at times contain substances considered harmful to the environment, and it
is the job of the scrubber to either remove those substances from the exhaust gas stream, or to neutralize those
substances so that they cannot do any harm once emitted into the environment as part of the exhaust gas
stream...
Wet scrubbing
A wet scrubber is used to clean air or other gases of various pollutants and dust particles. Wet scrubbing works
via the contact of target compounds or particulate matter with the scrubbing solution. Solutions may simply be
water (for dust) or complex solutions of reagents that specifically target certain compounds.
Removal efficiency of pollutants is improved by increasing residence time in the scrubber or by the increase of
surface area of the scrubber solution by the use of a spray nozzle, packed towers or an aspirator. Wet scrubbers
will often significantly increase the proportion of water in waste gases of industrial processes which can be seen
in a stack plume.
Bacteria spread
Until recently, scrubbers have not been associated with health risks involving bacteria spread as a result of
inadequate cleaning, unlike other devices such as cooling towers. However, a 2005 outbreak of Legionnaires'
disease in Norway was proven to emanate from a scrubber, causing ten deaths and more than fifty cases of
infection as it spread the bacteria through the air during a period of only two scrubbers being the source of such
bacteria
Packed bed tower Figure 1
–
Terminology
The phenomenon of electromagnetic induction, connecting the electromotive force with relation to the magnetic
flux through the circuit, should not be confused with the electrostatic induction method for creating an electrical
charge in an object with another electrically charged object.
The equation is interpreted to say that if the spatial dependence of electric field were to curl counter-clockwise
on the page (by the right hand rule, that means the curl vector would point out of the page), then the magnetic
field would change in time to point less out of the page and more into the page (the opposite sign to the curl
vector). The equation relates to change in the magnetic field. It does not mean that the magnetic field is
necessarily pointing into the page, only that it is changing towards pointing in that direction.
This equation, called in this article the Maxwell-Faraday equation, is best known as being one of the four
Maxwell's equations.
In the Maxwell-Faraday equation, Heaviside used the partial time derivative. Use of the partial time derivative,
instead of the total time derivative that had been used by Maxwell, means that the Maxwell-Faraday equation
does not account for motional EMF.[3] Nonetheless, the Maxwell-Faraday equation often simply is called
"Faraday's law".[4]
In this article the term "Faraday's law" refers to the flux equation, and "Maxwell-Faraday equation" refers to the
curl equation of Heaviside that today is one of Maxwell's equations.
Flux through a surface and EMF around a loop
Figure 1: The definition of surface integral relies on splitting the surface into small surface
elements. Each element is associated with a vector dA of magnitude equal to the area of the
element and with direction normal to the element and pointing outward.
Figure 2: A vector field F ( r, t ) defined throughout space, and a surface Σ bounded by curve ∂Σ
moving with velocity v over which the field is integrated.
Faraday's law of induction makes use of the magnetic flux ΦB through a surface Σ, defined by an integral over a
surface:
where dA is an element of surface area of the moving surface Σ(t), B is the magnetic field, and B•dA is a vector
dot product. See Figure 1. For more detail, refer to surface integral and magnetic flux. The surface is considered
to have a "mouth" outlined by a closed curve denoted ∂Σ(t). See Figure 2.
When the flux changes, Faraday's law of induction says that the work done (per unit charge) moving a test
charge around the closed curve ∂Σ(t), called the electromotive force (EMF), is given by:
where:
is the electromotive force (emf) in volts
ΦB is the magnetic flux in webers. The direction of the electromotive force (the negative
sign in the above formula) is given by Lenz's law.
For a tightly-wound coil of wire, composed of N identical loops, each with the same ΦB, Faraday's law of
induction states that
where:N is the number of turns of wire
ΦB is the magnetic flux in webers through a single loop.
In choosing a path ∂Σ(t) to find EMF, the path must satisfy the basic requirements that (i) it is a closed path, and
(ii) the path must capture the relative motion of the parts of the circuit (the origin of the t-dependence in ∂Σ(t) ).
It is not a requirement that the path follow a line of current flow, but of course the EMF that is found using the
flux law will be the EMF around the chosen path. If a current path is not followed, the EMF might not be the
EMF driving the current.
Example: Spatially varying B-field
Figure 3: Closed rectangular wire loop moving along x-axis at velocity v in magnetic field B that
varies with position x.
Consider the case in Figure 3 of a closed rectangular loop of wire in the xy-plane translated in the x-direction at
velocity v. Thus, the center of the loop at xC satisfies v = dxC / dt. The loop has length ℓ in the y-direction and
width w in the x-direction. A time-independent but spatially varying magnetic field B(x) points in the z-
direction. The magnetic field on the left side is B( xC − w / 2), and on the right side is B( xC + w / 2). The
electromotive force is to be found directly and by using Faraday's law above.
Lorentz force law method
A charge q in the wire on the left side of the loop experiences a Lorentz force q v × B k = −q v B(xC − w / 2) j (
j, k unit vectors in the y- and z-directions; see vector cross product), leading to an EMF (work per unit charge)
of v ℓ B(xC − w / 2) along the length of the left side of the loop. On the right side of the loop the same argument
shows the EMF to be v ℓ B(xC + w / 2). The two EMF's oppose each other, both pushing positive charge toward
the bottom of the loop. In the case where the B-field increases with position x, the force on the right side is
largest, and the current will be clockwise: using the right-hand rule, the B-field generated by the current opposes
the impressed field.[5] The EMF driving the current must increase as we move counterclockwise (opposite to the
current). Adding the EMF's in a counterclockwise tour of the loop we find
Faraday's law method
At any position of the loop the magnetic flux through the loop is
The sign choice is decided by whether the normal to the surface points in the same direction as B, or in the
opposite direction. If we take the normal to the surface as pointing in the same direction as the B-field of the
induced current, this sign is negative. The time derivative of the flux is then (using the chain rule of
differentiation or the general form of Leibniz rule for differentiation of an integral):
(where v = dxC / dt is the rate of motion of the loop in the x-direction ) leading to:
as before.
The equivalence of these two approaches is general and, depending on the example, one or the other method
may prove more practical.
Example: Moving loop in uniform B-field
Figure 4: Rectangular wire loop rotating at angular velocity ω in radially outward pointing
magnetic field B of fixed magnitude. Current is collected by brushes attached to top and bottom
discs, which have conducting rims.
Figure 4 shows a spindle formed of two discs with conducting rims and a conducting loop attached vertically
between these rims. The entire assembly spins in a magnetic field that points radially outward, but is the same
magnitude regardless of its direction. A radially oriented collecting return loop picks up current from the
conducting rims. At the location of the collecting return loop, the radial B-field lies in the plane of the collecting
loop, so the collecting loop contributes no flux to the circuit. The electromotive force is to be found directly and
by using Faraday's law above.
Lorentz force law method
In this case the Lorentz force drives the current in the two vertical arms of the moving loop downward, so
current flows from the top disc to the bottom disc. In the conducting rims of the discs, the Lorentz force is
perpendicular to the rim, so no EMF is generated in the rims, nor in the horizontal portions of the moving loop.
Current is transmitted from the bottom rim to the top rim through the external return loop, which is oriented so
the B-field is in its plane. Thus, the Lorentz force in the return loop is perpendicular to the loop, and no EMF is
generated in this return loop. Traversing the current path in the direction opposite to the current flow, work is
done against the Lorentz force only in the vertical arms of the moving loop, where
Consequently the EMF is
where ℓ is the vertical length of the loop, and the velocity is related to the angular rate of rotation by v = r ω,
with r = radius of cylinder. Notice that the same work is done on any path that rotates with the loop and
connects the upper and lower rim.
Faraday's law method
An intuitively appealing but mistaken approach to using the flux rule would say the flux through the circuit was
just ΦB = B w ℓ, where w = width of the moving loop. This number is time-independent, so the approach
predicts incorrectly that no EMF is generated. The flaw in this argument is that it fails to consider the entire
current path, which is a closed loop.
To use the flux rule, we have to look at the entire current path, which includes the path through the rims in the
top and bottom discs. We can choose an arbitrary closed path through the rims and the rotating loop, and the
flux law will find the EMF around the chosen path. Any path that has a segment attached to the rotating loop
captures the relative motion of the parts of the circuit.
As an example path, let's traverse the circuit in the direction of rotation in the top disc, and in the direction
opposite to the direction of rotation in the bottom disc (shown by arrows in Figure 4). In this case, for the
moving loop at an angle θ from the collecting loop, a portion of the cylinder of area A = r ℓ θ is part of the
circuit. This area is perpendicular to the B-field, and so contributes to the flux an amount:
where the sign is negative because the right-hand rule suggests the B-field generated by the current loop is
opposite in direction to the applied B field. As this is the only time-dependent portion of the flux, the flux law
predicts an EMF of
in agreement with the Lorentz force law calculation.
Now let's try a different path. Follow a path traversing the rims via the opposite choice of segments. Then the
coupled flux would decrease as θ increased, but the right-hand rule would suggest the current loop added to the
applied B-field, so the EMF around this path is the same as for the first path. Any mixture of return paths leads
to the same result for EMF, so it is actually immaterial which path is followed.
Direct evaluation of the change in flux
Figure 5: A simplified version of Figure 4. The loop slides with velocity v in a stationary,
homogeneous B-field.
The use of a closed path to find EMF as done above appears to depend upon details of the path geometry. In
contrast, the Lorentz-law approach is independent of such restrictions. A discussion follows intended to
understand better the equivalence of paths and escape the particulars of path selection when using the flux law.
Figure 5 is an idealization of Figure 4 with the cylinder unwrapped onto a plane. The same path-related analysis
works, but a simplification is suggested. The time-independent aspects of the circuit cannot affect the time-rate-
of-change of flux. For example, at a constant velocity of sliding the loop, the details of current flow through the
loop are not time dependent. Instead of concern over details of the closed loop selected to find the EMF, one can
focus on the area of B-field swept out by the moving loop. This suggestion amounts to finding the rate at which
flux is cut by the circuit.[6] That notion provides direct evaluation of the rate of change of flux, without concern
over the time-independent details of various path choices around the circuit. Just as with the Lorentz law
approach, it is clear that any two paths attached to the sliding loop, but differing in how they cross the loop,
produce the same rate-of-change of flux.
In Figure 5 the area swept out in unit time is simply dA / dt = v ℓ, regardless of the details of the selected closed
path, so Faraday's law of induction provides the EMF as:[7]
This path independence of EMF shows that if the sliding loop is replaced by a solid conducting plate, or even
some complex warped surface, the analysis is the same: find the flux in the area swept out by the moving
portion of the circuit. In a similar way, if the sliding loop in the drum generator of Figure 4 is replaced by a 360°
solid conducting cylinder, the swept area calculation is exactly the same as for the case with only a loop. That
is, the EMF predicted by Faraday's law is exactly the same for the case with a cylinder with solid conducting
walls or, for that matter, a cylinder with a cheese grater for walls. Notice, though, that the current that flows as a
result of this EMF will not be the same because the resistance of the circuit determines the current.
The Maxwell-Faraday equation
Figure 6: An illustration of Kelvin-Stokes theorem with surface Σ its boundary ∂Σ and orientation
n set by the right-hand rule.
A changing magnetic field creates an electric field; this phenomenon is described by the Maxwell-Faraday
equation:[8]
where: denotes curl E is the electric field B is the magnetic field
This equation appears in modern sets of Maxwell's equations and is often referred to as Faraday's law. However,
because it contains only partial time derivatives, its application is restricted to situations where the test charge is
stationary in a time varying magnetic field. It does not account for electromagnetic induction in situations where
a charged particle is moving in a magnetic field.
It also can be written in an integral form by the Kelvin-Stokes theorem:[9]
where the movement of the derivative before the integration requires a time-independent surface Σ (considered
in this context to be part of the interpretation of the partial derivative), and as indicated in Figure 6:
Σ is a surface bounded by the closed contour ∂Σ; both Σ and ∂Σ are fixed, independent of
time
E is the electric field, dℓ is an infinitesimal vector element of the contour ∂Σ, B is the
magnetic field.
dA is an infinitesimal vector element of surface Σ , whose magnitude is the area of an
infinitesimal patch of surface, and whose direction is orthogonal to that surface patch.
Both dℓ and dA have a sign ambiguity; to get the correct sign, the right-hand rule is used, as explained in the
article Kelvin-Stokes theorem. For a planar surface Σ, a positive path element dℓ of curve ∂Σ is defined by the
right-hand rule as one that points with the fingers of the right hand when the thumb points in the direction of the
normal n to the surface Σ.
The integral around ∂Σ is called a path integral or line integral. The surface integral at the right-hand side of the
Maxwell-Faraday equation is the explicit expression for the magnetic flux ΦB through Σ. Notice that a nonzero
path integral for E is different from the behavior of the electric field generated by charges. A charge-generated
E-field can be expressed as the gradient of a scalar field that is a solution to Poisson's equation, and has a zero
path integral. See gradient theorem.
The integral equation is true for any path ∂Σ through space, and any surface Σ for which that path is a boundary.
Note, however, that ∂Σ and Σ are understood not to vary in time in this formula. This integral form cannot treat
motional EMF because Σ is time-independent. Notice as well that this equation makes no reference to EMF ,
and indeed cannot do so without introduction of the Lorentz force law to enable a calculation of work.
Figure 7: Area swept out by vector element dℓ of curve ∂Σ in time dt when moving with velocity
v.
History
Faraday's law was originally an experimental law based upon observation.[15][16] Later it was formalized, and
along with the other laws of electromagnetism a partial time derivative restricted version of it was incorporated
into the modern Heaviside versions of Maxwell's equations.
Faraday's law of induction is based on Michael Faraday's experiments in 1831. The effect was also discovered
by Joseph Henry at about the same time, but Faraday published first.[17][18]
See Maxwell's original discussion of induced electromotive force.[19]
Lenz's law, formulated by Baltic German physicist Heinrich Lenz in 1834, gives the direction of the induced
electromotive force and current resulting from electromagnetic induction.
Electrical generator
Faraday's disc electric generator. The disc rotates with angular rate ω, sweeping the conducting
radius circularly in the static magnetic field B. The magnetic Lorentz force v × B drives the
current along the conducting radius to the conducting rim, and from there the circuit completes
through the lower brush and the axle supporting the disc. Thus, current is generated from
mechanical motion.
The EMF generated by Faraday's law of induction due to relative movement of a circuit and a magnetic field is
the phenomenon underlying electrical generators. When a permanent magnet is moved relative to a conductor,
or vice versa, an electromotive force is created. If the wire is connected through an electrical load, current will
flow, and thus electrical energy is generated, converting the mechanical energy of motion to electrical energy.
For example, the drum generator is based upon Figure 4. A different implementation of this idea is the
Faraday's disc, shown in simplified form in Figure 8. Note that either the analysis of Figure 5, or direct
application of the Lorentz force law, shows that a solid conducting disc works the same way.
In the Faraday's disc example, the disc is rotated in a uniform magnetic field perpendicular to the disc, causing a
current to flow in the radial arm due to the Lorentz force. It is interesting to understand how it arises that
mechanical work is necessary to drive this current. When the generated current flows through the conducting
rim, a magnetic field is generated by this current through Ampere's circuital law (labeled "induced B" in Figure
8). The rim thus becomes an electromagnet that resists rotation of the disc (an example of Lenz's law). On the
far side of the figure, the return current flows from the rotating arm through the far side of the rim to the bottom
brush. The B-field induced by this return current opposes the applied B-field, tending to decrease the flux
through that side of the circuit, opposing the increase in flux due to rotation. On the near side of the figure, the
return current flows from the rotating arm through the near side of the rim to the bottom brush. The induced B-
field increases the flux on this side of the circuit, opposing the decrease in flux due to rotation. Thus, both sides
of the circuit generate an emf opposing the rotation. The energy required to keep the disc moving, despite this
reactive force, is exactly equal to the electrical energy generated (plus energy wasted due to friction, Joule
heating, and other inefficiencies). This behavior is common to all generators converting mechanical energy to
electrical energy.
Although Faraday's law always describes the working of electrical generators, the detailed mechanism can
differ in different cases. When the magnet is rotated around a stationary conductor, the changing magnetic field
creates an electric field, as described by the Maxwell-Faraday equation, and that electric field pushes the
charges through the wire. This case is called an induced EMF. On the other hand, when the magnet is stationary
and the conductor is rotated, the moving charges experience a magnetic force (as described by the Lorentz force
law), and this magnetic force pushes the charges through the wire. This case is called motional EMF. (For more
information on motional EMF, induced EMF, Faraday's law, and the Lorentz force, see above example, and see
Griffiths[20].)
Electrical motor
An electrical generator can be run "backwards" to become a motor. For example, with the Faraday disc, suppose
a DC current is driven through the conducting radial arm by a voltage. Then by the Lorentz force law, this
traveling charge experiences a force in the magnetic field B that will turn the disc in a direction given by
Fleming's left hand rule. In the absence of irreversible effects, like friction or Joule heating, the disc turns at the
rate necessary to make d ΦB / dt equal to the voltage driving the current.
Electrical transformer
The EMF predicted by Faraday's law is also responsible for electrical transformers. When the electric current in
a loop of wire changes, the changing current creates a changing magnetic field. A second wire in reach of this
magnetic field will experience this change in magnetic field as a change in its coupled magnetic flux, a d ΦB / d
t. Therefore, an electromotive force is set up in the second loop called the induced EMF or transformer EMF.
If the two ends of this loop are connected through an electrical load, current will flow.
Magnetic flow meter
Faraday's law is used for measuring the flow of electrically conductive liquids and slurries. Such instruments
are called magnetic flow meters. The induced voltage ε generated in the magnetic field B due to a conductive
liquid moving at velocity v is thus given by:
where ℓ is the distance between electrodes in the magnetic flow meter.
P
RPM at RPM at
ole
50 Hz 60 Hz
s
2 3000 3600
4 1500 1800
6 1000 1200
8 750 900
10 600 720
1 428. 514.
4 6 3
1
375 450
6
1 333.
400
8 3
2
300 360
0
Automotive alternators
Alternators are used in modern automobiles to charge the battery and to power a car's electric system when its
engine is running. Alternators have the great advantage over direct-current generators of not using a
commutator, which makes them simpler, lighter, less costly, and more rugged than a DC generator. The stronger
construction of automotive alternators allows them to use a smaller pulley so as to turn twice as fast as the
engine, improving output when the engine is idling. The availability of low-cost solid-state diodes from about
1960 onward allowed car manufacturers to substitute alternators for DC generators. Automotive alternators use
a set of rectifiers (diode bridge) to convert AC to DC. To provide direct current with low ripple, automotive
alternators have a three-phase winding.
Typical passenger vehicle and light truck alternators use Lundell or claw-pole field construction, where the field
north and south poles are all energized by a single winding, with the poles looking rather like fingers of two
hands interlocked with each other. Larger vehicles may have salient-pole alternators similar to larger machines.
The automotive alternator is usually belt driven at 2-3 times the engine crankshaft speed.
Modern automotive alternators have a voltage regulator built into them. The voltage regulator operates by
modulating the small field current in order to produce a constant voltage at the stator output. The field current is
much smaller than the output current of the alternator; for example, a 70-amp alternator may need only 2 amps
of field current. The field current is supplied to the rotor windings by slip rings and brushes. The low current
and relatively smooth slip rings ensure greater reliability and longer life than that obtained by a DC generator
with its commutator and higher current being passed through its brushes.
Efficiency of automotive alternators is limited by fan cooling loss, bearing loss, iron loss, copper loss, and the
voltage drop in the diode bridges; at part load, efficiency is between 50-62% depending on the size of alternator,
and varies with alternator speed.[7] In comparison, very small high-performance permanent magnet alternators,
such as those used for bicycle lighting systems, achieve an efficiency of around only 60%. Larger permanent
magnet alternators can achieve much higher efficiency.
The field windings are initially supplied via the ignition switch and charge warning light, which is why the light
glows when the ignition is on but the engine is not running. Once the engine is running and the alternator is
generating, a diode feeds the field current from the alternator main output, thus equalizing the voltage across the
warning light which goes out. The wire supplying the field current is often referred to as the "exciter" wire. The
drawback of this arrangement is that if the warning light fails or the "exciter" wire is disconnected, no excitation
current reaches the alternator field windings and so the alternator, due to low residual magnetism in the rotor
will not generate any power. However, some alternators will self-excite when the engine is revved to a certain
speed. The driver may check for a faulty exciter-circuit by ensuring that the warning light is glowing with the
engine stopped.
Very large automotive alternators used on buses, heavy equipment or emergency vehicles may produce 300
amperes. Very old automobiles with minimal lighting and electronic devices may have only a 30 ampere
alternator. Typical passenger car and light truck alternators are rated around 50-70 amperes, though higher
ratings are becoming more common. Very large automotive alternators may be water-cooled or oil-cooled.
Many alternator voltage regulators are today linked to the vehicle's on board computer system, and in recent
years other factors including air temperature (gained from the mass air flow sensor in many cases) and engine
load are considered in adjusting the battery charging voltage supplied by the alternator.
Electrostatic precipitator
An electrostatic precipitator (ESP), or electrostatic air cleaner is a particulate collection device that removes
particles from a flowing gas (such as air) using the force of an induced electrostatic charge. Electrostatic
precipitators are highly efficient filtration devices that minimally impede the flow of gases through the device,
and can easily remove fine particulate matter such as dust and smoke from the air stream.[1]
Types
There are two types of air preheaters for use in steam generators in thermal power stations: One is a tubular type
built into the boiler flue gas ducting, and the other is a regenerative air preheater.[1][2][6] These may be arranged
so the gas flows horizontally or vertically across the axis of rotation.
Another type of air preheater is the regenerator used in iron or glass manufacture.
Tubular type
Construction features
Tubular preheaters consist of straight tube bundles which pass through the outlet ducting of the boiler and open
at each end outside of the ducting. Inside the ducting, the hot furnace gases pass around the preheater tubes,
transferring heat from the exhaust gas to the air inside the preheater. Ambient air is forced by a fan through
ducting at one end of the preheater tubes and at other end the heated air from inside of the tubes emerges into
another set of ducting, which carries it to the boiler furnace for combustion.
Problems
The tubular preheater ductings for cold and hot air require more space and structural supports than a rotating
preheater design. Further, due to dust-laden abrasive flue gases, the tubes outside the ducting wear out faster on
the side facing the gas current. Many advances have been made to eliminate this problem such as the use of
ceramic and hardened steel.
Many new circulating fluidized bed (CFB) and bubbling fluidized bed (BFB) steam generators are currently
incorporating tubular air heaters offering an advantage with regards to the moving parts of a rotary type.
Dew point corrosion
Dew point corrosion occurs for a variety of reasons.[7][8] The type of fuel used, its sulfur content and moisture
content are contributing factors. However, by far the most significant cause of dew point corrosion is the metal
temperature of the tubes. If the metal temperature within the tubes drops below the acid saturation temperature,
usually at between 190°F (88°C)and 230°F (110°C), but sometimes at temperatures as high as 260°F (127°C),
then the risk of dew point corrosion damage becomes considerable.
Regenerative air preheaters
There are two types of regenerative air preheaters: the rotating-plate regenerative air preheaters (RAPH) and the
stationary-plate regenerative air preheaters (Rothemuhle).[1][2][3][9]
Rotating-plate regenerative air preheater
Typical Rotating-plate Regenerative Air Preheater (Bi-sector type)[10]
The rotating-plate design (RAPH)[2] consists of a central rotating-plate element installed within a casing that is
divided into two (bi-sector type, three (tri-sector type) or four quad-sector type) sectors containing seals around
the element. The seals allow the element to rotate through all the sectors, but keep gas leakage between sectors
to a minimum while providing separate gas air and flue gas paths through each sector.
Tri-sector types are the most common in modern power generation facilities.[11] In the tri-sector design, the
largest sector (usually spanning about half the cross-section of the casing) is connected to the boiler hot gas
outlet. The hot exhaust gas flows over the central element, transferring some of its heat to the element, and is
then ducted away for further treatment in dust collectors and other equipment before being expelled from the
flue gas stack. The second, smaller sector, is fed with ambient air by a fan, which passes over the heated
element as it rotates into the sector, and is heated before being carried to the boiler furnace for combustion. The
third sector is the smallest one and it heats air which is routed into the pulverizers and used to carry the coal-air
mixture to coal boiler burners. Thus, the total air heated in the RAPH provides: heating air to remove the
moisture from the pulverised coal dust, carrier air for transporting the pulverised coal to the boiler burners and
the primary air for combustion.
The rotor itself is the medium of heat transfer in this system, and is usually composed of some form of steel
and/or ceramic structure. It rotates quite slowly (around 3-5 RPM) to allow optimum heat transfer first from the
hot exhaust gases to the element, then as it rotates, from the element to the cooler air in the other sectors.
Construction features
In this design the whole air preheater casing is supported on the boiler supporting structure itself with necessary
expansion joints in the ducting.
The vertical rotor is supported on thrust bearings at the lower end and has an oil bath lubrication, cooled by
water circulating in coils inside the oil bath. This arrangement is for cooling the lower end of the shaft, as this
end of the vertical rotor is on the hot end of the ducting. The top end of the rotor has a simple roller bearing to
hold the shaft in a vertical position.
The rotor is built up on the vertical shaft with radial supports and cages for holding the baskets in position.
Radial and circumferential seal plates are also provided to avoid leakages of gases or air between the sectors or
between the duct and the casing while in rotation.
For on line cleaning of the deposits from the baskets steam jets are provided such that the blown out dust and
ash are collected at the bottom ash hopper of the air preheater. This dust hopper is connected for emptying along
with the main dust hoppers of the dust collectors.
The rotor is turned by an air driven motor and gearing, and is required to be started before starting the boiler and
also to be kept in rotation for some time after the boiler is stopped, to avoid uneven expansion and contraction
resulting in warping or cracking of the rotor. The station air is generally totally dry (dry air is required for the
instrumentation), so the air used to drive the rotor is injected with oil to lubricate the air motor.
Safety protected inspection windows are provided for viewing the preheater's internal operation under all
operating conditions.
The baskets are in the sector housings provided on the rotor and are renewable. The life of the baskets depend
on the ash abrasiveness and corrosiveness of the boiler outlet gases.
Problems
The boiler flue gas contains many dust particles (due to high ash content) not contributing towards combustion,
such as silica, which cause abrasive wear of the baskets, and may also contain corrosive gases depending on the
composition of the fuel. For example, Indian coals [1] generally result in high levels of ash, sulfur and silica in
the flue gas. The wear of the baskets therefore is generally more than other, cleaner-burning fuels.
In this RAPH, the dust laden, corrosive boiler gases have to pass between the elements of air preheater baskets.
The elements are made up of zig zag corrugated plates pressed into a steel basket giving sufficient annular space
in between for the gas to pass through. These plates are corrugated to give more surface area for the heat to be
absorbed and also to give it the rigidity for stacking them into the baskets. Hence frequent replacements are
called for and new baskets are always kept ready. In the early days, Cor-ten steel was being used for the
elements. Today due to technological advance many manufacturers may use their own patents. Some
manufacturers supply different materials for the use of the elements to lengthen the life of the baskets.
In certain cases the unburnt deposits may occur on the air preheater elements causing it to catch fire during
normal operations of the boiler, giving rise to explosions inside the air preheater. Sometimes mild explosions
may be detected in the control room by variations in the inlet and outlet temperatures of the combustion air.
Schematic of typical stationary-plate regenerative air preheater
•
History
The regenerator was invented by Rev. Robert Stirling in 1816, and is commonly found as a component of his
Stirling engine. The simplest Stirlings, and most models, use a less efficient but simpler to construct, displacer
instead.
Types of regenerators
This section contains too much jargon and may need simplification or further explanation.
Please discuss this issue on the talk page, and/or remove or explain jargon terms used in the
article. Editing help is available. (April 2008)
In rotary regenerators the matrix rotates continuously through two counter-flowing streams of fluid. In this
way, the two streams are mostly separated but the seals are generally not perfect. Only one stream flows through
each section of the matrix at a time; however, over the course of a rotation, both streams eventually flow
through all sections of the matrix in succession. Each portion of the matrix will be nearly isothermal, since the
rotation is perpendicular to both the temperature gradient and flow direction, and not through them. The two
fluid streams flow counter-current. The fluid temperatures vary across the flow area; however the local stream
temperatures are not a function of time.
In a fixed matrix regenerator, a single fluid stream has cyclical, reversible flow; it is said to flow "counter-
current". This regenerator may be part of a valveless system, such as a Stirling engine. In another configuration,
the fluid is ducted through valves to different matrices in alternate operating periods Ph and Pc resulting in
outlet temperatures that vary with time.
Another type of regenerator is called a micro scale Regenerative Heat Exchanger. It has a multilayer grating
structure in which each layer is offset from the adjacent layer by half a cell which has an opening along both
axes perpendicular to the flow axis. Each layer is a composite structure of two sublayers, one of a high thermal
conductivity material and another of a low thermal conductivity material. When a hot fluid flows through the
cell, heat from the fluid is transferred to the cell wells, and stored there. When the fluid flow reverses direction,
heat is transferred from the cell walls back to the fluid.
A third type of regenerator is called a "Rothemuhle" regenerator. This type has a fixed matrix in a disk shape,
and streams of fluid are ducted through rotating hoods. The Rothemuhle regenerator is used as an air preheater
in some power generating plants. The thermal design of this regenerator is the same as of other types of
regenerators.[citation needed]
Cryogenics
Regenerator heat exchangers are made up of materials with high volumetric heat capacity and low thermal
conductivity in the longitudinal (flow) direction. At cryogenic (very low) temperatures around 20K, the specific
heat of metals are low, and so a regenerator must be larger for a given heat load.
Advantages of regenerators
The advantages of a regenerator over a recuperating (counter-flowing) heat exchanger is that it has a much
higher surface area for a given volume, which provides a reduced exchanger volume for a given energy density,
effectiveness and pressure drop. This makes a regenerator more economical in terms of materials and
manufacturing, compared to an equivalent recuperator.
The design of inlet and outlet headers used to distribute hot and cold fluids in the matrix is much simpler in
counter flow regenerators than recuperators. The reason behind this is that both streams flow in different
sections for a rotary regenerator and one fluid enters and leaves one matrix at a time in a fixed-matrix
regenerator. Furthermore flow sectors for hot and cold fluids in rotary regenerators can be designed to optimize
pressure drop in the fluids. The matrix surfaces of regenerators also have self-cleaning characteristics, reducing
fluid-side fouling and corrosion. Finally properties such as small surface density and counter-flow arrangement
of regenerators make it ideal for gas-gas heat exchange applications requiring effectiveness exceeding 85%. The
heat transfer coefficient is much lower for gases than for liquids, thus the enormous surface area in a regenerator
greatly increases heat transfer.
Disadvantages of regenerators
The major disadvantage of a regenerator is that there is always some mixing of the fluid streams, and they can
not be completely separated.[citation needed] There is an unavoidable carryover of a small fraction of one fluid stream
into the other. In the rotary regenerator, the carryover fluid is trapped inside the radial seal and in the matrix,
and in a fixed-matrix regenerator, the carryover fluid is the fluid that remains in the void volume of the matrix.
This small fraction will mix with the other stream in the following half-cycle. Therefore regenerators are only
used when it is acceptable for the two fluid streams to be mixed. Mixed flow is common for gas-to-gas heat
and/or energy transfer applications, and less common in liquid or phase-changing fluids since fluid
contamination is often prohibited with liquid flows.
A recuperator is a special purpose counter-flow heat exchanger used to recover waste heat from exhaust gases.
In many types of processes, combustion is used to generate heat, and the recuperator serves to recuperate, or
reclaim this heat, in order to reuse or recycle it. The term recuperator refers as well to liquid-liquid counterflow
heat exchangers used for heat recovery in the chemical and refinery industries and in closed processes such as
ammonia-water or LiBr-water absorption refrigeration cycles. Other forms of heat or enthalpy recovery include
the regenerative heat exchanger (see blast furnace), the heat wheel (see rotating recuperator, below), and the
enthalpy wheel (see energy recovery ventilation).
Recuperators are often used in association with the burner portion of a heat engine, to increase the overall
efficiency. For example, in a gas turbine engine, air is compressed, mixed with fuel, which is then burned and
used to drive a turbine. The recuperator transfers some of the waste heat in the exhaust to the compressed air,
thus preheating it before entering the fuel burner stage. Since the gases have been pre-heated, less fuel is needed
to heat the gases up to the turbine inlet temperature. By recovering some of the energy usually lost as waste
heat, the recuperator can make a heat engine or gas turbine significantly more efficient.
Rotating recuperator
During the automotive industry's interest in gas turbines for vehicle propulsion (around 1965), Chrysler
invented a unique recuperator[1] that consisted of a rotary drum constructed from corrugated metal (similar in
appearance to corrugated cardboard). This drum was continuously rotated by reduction gears driven by the
turbine. The hot exhaust gasses were directed through a portion of the device, which would then rotate to a
section that conducted the induction air, where this intake air was heated. This recovery of the heat of
combustion significantly increased the efficiency of the turbine engine. This engine proved impractical for an
automotive application due to its poor low-rpm torque. Even such an efficient engine, if large enough to deliver
the proper performance, would have a low average fuel economy. Such an engine may at some future time be
attractive when combined with an electric motor in a hybrid vehicle owing to its robust longevity and an ability
to burn a wide variety of liquid fuels.
Feedwater heater
A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating
boiler.[1][2][3] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore
improves the thermodynamic efficiency of the system.[4] This reduces plant operating costs and also helps to
avoid thermal shock to the boiler metal when the feedwater is introduced back into the steam cycle.
In a steam power plant (usually modeled as a modified Rankine cycle), feedwater heaters allow the feedwater to
be brought up to the saturation temperature very gradually. This minimizes the inevitable irreversibilities
associated with heat transfer to the working fluid (water). See the article on the Second Law of
Thermodynamics for a further discussion of such irreversibilities.
Types of deaerators
There are many different horizontal and vertical designs available from a number of manufacturers, and the
actual construction details will vary from one manufacturer to another. Figures 1 and 2 are representative
schematic diagrams that depict each of the two major types of deaerators.
Tray-type deaerator
Figure 1: A schematic diagram of a typical tray-type deaerator.
The typical horizontal tray-type deaerator in Figure 1 has a vertical domed deaeration section mounted above a
horizontal boiler feedwater storage vessel. Boiler feedwater enters the vertical dearation section above the
perforated trays and flows downward through the perforations. Low-pressure dearation steam enters below the
perforated trays and flows upward through the perforations. Some designs use various types of packing
material, rather than perforated trays, to provide good contact and mixing between the steam and the boiler feed
water.
The steam strips the dissolved gas from the boiler feedwater and exits via the vent at the top of the domed
section. Some designs may include a vent condenser to trap and recover any water entrained in the vented gas.
The vent line usually includes a valve and just enough steam is allowed to escape with the vented gases to
provide a small and visible telltale plume of steam.
The deaerated water flows down into the horizontal storage vessel from where it is pumped to the steam
generating boiler system. Low-pressure heating steam, which enters the horizontal vessel through a sparger
pipe in the bottom of the vessel, is provided to keep the stored boiler feedwater warm. External insulation of the
vessel is typically provided to minimize heat loss.
Spray-type deaerator
Figure 2: A schematic diagram of a typical spray-type deaerator.
As shown in Figure 2, the typical spray-type deaerator is a horizontal vessel which has a preheating section (E)
and a deaeration section (F). The two sections are separated by a baffle(C). Low-pressure steam enters the
vessel through a sparger in the bottom of the vessel.
The boiler feedwater is sprayed into section (E) where it is preheated by the rising steam from the sparger. The
purpose of the feedwater spray nozzle (A) and the preheat section is to heat the boiler feedwater to its saturation
temperature to facilitate stripping out the dissolved gases in the following deaeration section.
The preheated feedwater then flows into the dearation section (F), where it is deaerated by the steam rising from
the sparger system. The gases stripped out of the water exit via the vent at the top of the vessel. Again, some
designs may include a vent condenser to trap and recover any water entrained in the vented gas. Also again, the
vent line usually includes a valve and just enough steam is allowed to escape with the vented gases to provide a
small and visible telltale plume of steam
The deaerated boiler feedwater is pumped from the bottom of the vessel to the steam generating boiler system.
Deaeration steam
The deaerators in the steam generating systems of most thermal power plants use low pressure steam obtained
from an extraction point in their steam turbine system. However, the steam generators in many large industrial
facilities such as petroleum refineries may use whatever low-pressure steam that is available.
Oxygen scavengers
Oxygen scavenging chemicals are very often added to the deaerated boiler feedwater to remove any last traces
of oxygen that were not removed by the deaerator. The most commonly used oxygen scavenger is sodium
sulfite (Na2SO3). It is very effective and rapidly reacts with traces of oxygen to form sodium sulfate (Na2SO4)
which is non-scaling.
Other scavengers include 1,3-diaminourea (also known as carbohydrazide), diethylhydroxylamine (DEHA),
nitriloacetic acid (NTA), ethylenediaminetetraacetic acid (EDTA), and hydroquinone
Surface condenser
Surface condenser is the commonly used term for a water cooled shell and tube heat exchanger installed on the
exhaust steam from a steam turbine in thermal power stations.[1][2][3] These condensers are heat exchangers which
convert steam from its gaseous to its liquid state at a pressure below atmospheric pressure. Where cooling water
is in short supply, an air-cooled condenser is often used. An air-cooled condenser is however significantly more
expensive and cannot achieve as low a steam turbine exhaust pressure as a surface condenser.
Surface condensers are also used in applications and industries other than the condensing of steam turbine
exhaust in power plants.
•
Purpose
In thermal power plants, the primary purpose of a surface condenser is to condense the exhaust steam from a
steam turbine to obtain maximum efficiency and also to convert the turbine exhaust steam into pure water
(referred to as steam condensate) so that it may be reused in the steam generator or boiler as boiler feed water.
Why is it required?
The steam turbine itself is a device to convert the heat in steam to mechanical power. The difference between
the heat of steam per unit weight at the inlet to the turbine and the heat of steam per unit weight at the outlet to
the turbine represents the heat which is converted to mechanical power. Therefore, the more the conversion of
heat per pound or kilogram of steam to mechanical power in the turbine, the better is its efficiency. By
condensing the exhaust steam of a turbine at a pressure below atmospheric pressure, the steam pressure drop
between the inlet and exhaust of the turbine is increased, which increases the amount of heat available for
conversion to mechanical power. Most of the heat liberated due to condensation of the exhaust steam is carried
away by the cooling medium (water or air) used by the surface condenser.
Diagram of water-cooled surface condenser
Diagram of a typical water-cooled surface condenser
The adjacent diagram depicts a typical water-cooled surface condenser as used in power stations to condense
the exhaust steam from a steam turbine driving an electrical generator as well in other applications.[2][3][4][5] There
are many fabrication design variations depending on the manufacturer, the size of the steam turbine, and other
site-specific conditions.
Shell
The shell is the condenser's outermost body and contains the heat exchanger tubes. The shell is fabricated from
carbon steel plates and is stiffened as needed to provide rigidity for the shell. When required by the selected
design, intermediate plates are installed to serve as baffle plates that provide the desired flow path of the
condensing steam. The plates also provide support that help prevent sagging of long tube lengths.
At the bottom of the shell, where the condensate collects, an outlet is installed. In some designs, a sump (often
referred to as the hotwell) is provided. Condensate is pumped from the outlet or the hotwell for reuse as boiler
feedwater.
For most water-cooled surface condensers, the shell is under vacuum during normal operating conditions.
Vacuum system
Diagram of a typical modern injector or ejector. For a steam ejector, the motive fluid is steam.
For water-cooled surface condensers, the shell's internal vacuum is most commonly supplied by and maintained
by an external steam jet ejector system. Such an ejector system uses steam as the motive fluid to remove any
non-condensible gases that may be present in the surface condenser. The Venturi effect, which is a particular
case of Bernoulli's principle, applies to the operation of steam jet ejectors.
Motor driven mechanical vacuum pumps, such as liquid ring type vacuum pumps, are also popular for this
service.
Tube sheets
At each end of the shell, a sheet of sufficient thickness usually made of stainless steel is provided, with holes for
the tubes to be inserted and rolled. The inlet end of each tube is also bellmouthed for streamlined entry of water.
This is to avoid eddies at the inlet of each tube giving rise to erosion, and to reduce flow friction. Some makers
also recommend plastic inserts at the entry of tubes to avoid eddies eroding the inlet end. In smaller units some
manufacturers use ferrules to seal the tube ends instead of rolling. To take care of length wise expansion of
tubes some designs have expansion joint between the shell and the tube sheet allowing the latter to move
longitudinally. In smaller units some sag is given to the tubes to take care of tube expansion with both end water
boxes fixed rigidly to the shell.
Tubes
Generally the tubes are made of stainless steel, copper alloys such as brass or bronze, cupro nickel, or titanium
depending on several selection criteria. The use of copper bearing alloys such as brass or cupro nickel is rare in
new plants, due to environmental concerns of toxic copper alloys. Also depending on the steam cycle water
treatment for the boiler, it may be desirable to avoid tube materials containing copper. Titanium condenser tubes
are usually the best technical choice, however the use of titanium condenser tubes has been virtually eliminated
by the sharp increases in the costs for this material. The tube lengths range to about 55 ft (17 m) for modern
power plants, depending on the size of the condenser. The size chosen is based on transportability from the
manufacturers’ site and ease of erection at the installation site. The outer diameter of condenser tubes typically
ranges from 3/4 inch to 1-1/4 inch, based on condenser cooling water friction considerations and overall
condenser size.
Waterboxes
The tube sheet at each end with tube ends rolled, for each end of the condenser is closed by a fabricated box
cover known as a waterbox, with flanged connection to the tube sheet or condenser shell. The waterbox is
usually provided with man holes on hinged covers to allow inspection and cleaning.
These waterboxes on inlet side will also have flanged connections for cooling water inlet butterfly valves, small
vent pipe with hand valve for air venting at higher level, and hand operated drain valve at bottom to drain the
waterbox for maintenance. Similarly on the outlet waterbox the cooling water connection will have large
flanges, butterfly valves, vent connection also at higher level and drain connections at lower level. Similarly
thermometer pockets are located at inlet and outlet pipes for local measurements of cooling water temperature.
In smaller units, some manufacturers make the condenser shell as well as waterboxes of cast iron.
Corrosion
On the cooling water side of the condenser:
The tubes, the tube sheets and the water boxes may be made up of materials having different compositions and
are always in contact with circulating water. This water, depending on its chemical composition, will act as an
electrolyte between the metallic composition of tubes and water boxes. This will give rise to electrolytic
corrosion which will start from more anodic materials first.
'Sea water based condensers,' in particular when sea water has added chemical pollutants, have the worst
corrosion characteristics. River water with pollutants are also undesirable for condenser cooling water.
The corrosive effect of sea or river water has to be tolerated and remedial methods have to be adopted.
On the steam (shell) side of the condenser:
The concentration of undissolved gases is high over air zone tubes. Therefore these tubes are exposed to higher
corrosion rates. Some times these tubes are affected by stress corrosion cracking, if originally stress is not fully
relieved during manufacture. To overcome these effects of corrosion some manufacturers provide higher
corrosive resistant tubes in this area.
Effects of corrosion
As the tube ends get corroded there is the possibility of cooling water leakage to the steam side contaminating
the condensed steam or condensate, which is harmful to steam generators. The other parts of water boxes may
also get affected in the long run requiring repairs or replacements involving long duration shut-downs.
Protection from corrosion
Cathodic protection is typically employed to overcome this problem. Sacrificial anodes of zinc (being cheapest)
plates are mounted at suitable places inside the water boxes. These zinc plates will get corroded first being in
the lowest range of anodes. Hence these zinc anodes require periodic inspection and replacements. This
involves comparatively less down time. The water boxes made of steel plates are also protected inside by epoxy
paint.
Cross-sectional schematic diagram of a power plant condenser for condensing exhaust steam
from a steam turbine. This condenser is single-pass on both the tube and shell sides with a large
opening at the top for the exhaust steam to enter and a hotwell at the bottom where
condensate water drips down to and collects. Circulating water for cooling is shown in light
greenish color and condensate is light blue.