Professional Documents
Culture Documents
This information may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any electronic medium or machinereadable form without the prior written consent of Hatteland Display AS. The products may not be copied or duplicated in any way.
Hatteland Display AS 4 channel RS-422 / RS-485 COM module Last Revised: Revision#: 18 Apr 2013 11
5-pin Terminal Block 3.81 4 Ports (Virtual COM) identied in the Operating System (OS): COMx (A), COMx (B), COMx (C), COMx (D)* *Configuration dependent, x = next available port number(s) OS. RS-485 Half Duplex (2-wire, supports ECHO) Conguration: Connect TX and RX pair-wise: TX- to RX-, TX+ to RX+.
PIN 01 PIN 02 PIN 03 PIN 04 PIN 05 PIN 06 PIN 07 PIN 08 PIN 09 PIN 10
Transmit Data Negative Transmit Data Positive Isolated Ground Receive Data Negative Receive Data Positive Transmit Data Negative Transmit Data Positive Isolated Ground Receive Data Negative Receive Data Positive
*Note: The jumper for force of transmitter is open by factory default. For some custom models this jumper is preset to closed (active), in that case unit has to be opened and jumper set to open to allow Half Duplex mode.
Dimensions might be shown with or without decimals and indicated as mm [inches]. Tolerance on drawings is +/- 1mm. For accurate measurements, check relevant DWG le. Hatteland Display AS, msosen, N-5578 Nedre Vats, Norway Tel: (+47) 4814 2200 - mail@hatteland-display.com - www.hatteland-display.com