Materials System Specification

18-SAMSS-625 6 November 2010 Outside Plant Fiber Optic Cable Specifications (Single Mode & Multiple Mode) Document Responsibility: Communications Standards Committee

Saudi Aramco DeskTop Standards


Table of Contents 1 2 3 4 5 6 Scope............................................................. 2 Conflicts and Deviations................................. 2 References..................................................... 2 Definitions and Abbreviations......................... 5 Specifications................................................. 7 Testing and Inspection................................. 29

Previous Issue: 12 June 2010 Next Planned Update: 6 November 2015 Revised paragraphs are indicated in the right margin Primary contact: Ghamdi, Khalid Sulaiman on 966-3- 8745566
CopyrightSaudi Aramco 2010. All rights reserved.

Page 1 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

Scope This specification covers mandatory requirements governing the construction and performance of Long Haul single mode, and Inter and Intra building multimode Fiber Optic Cable systems for Voice, Video, Data communications and Local and Wide Area Network applications.

Conflicts and Deviations Any deviations, providing less than the mandatory requirements of this standard require written waiver approval as per Saudi Aramco Engineering Procedure SAEP-302.

References The selection of material and equipment, and the design, construction, maintenance, and repair of equipment and facilities covered by this specification shall comply with the latest edition of the references listed below, unless otherwise noted. 3.1 Saudi Aramco References Saudi Aramco Engineering Procedure SAEP-302 Instructions for Obtaining a Waiver of a Mandatory Saudi Aramco Engineering Requirement

Saudi Aramco Engineering Standard SAES-T-624 3.2 Telecommunications Outside Plant-Fiber Optics

Industry Codes and Standards Rural Development Utilities Program (formerly RUS) RDUP PE 90 Specification for Filled Fiber Optic Cables

American Society for Testing and Materials ASTM B736 ASTM D92 (Rev A) ASTM D566 ASTM D974 Standard Specification for Aluminum Alloy and Aluminum Clad Shielding Stock Standard Test Method for Flash and Fire Points by Cleveland Open IP Designation Standard Test Method for Dropping Point of Lubricating Grease IP Designation Standard Test Method for Acid and Base Numbers by Color - Indicator Titration IP Designation
Page 2 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

ASTM D1238 ASTM D1248 ASTM D4565

Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer Specification for Polyethylene Plastic Molding and Extrusion Materials Standard Test Method for Physical and Environmental Performance Properties of Insulations and Jackets for telecommunications Wire and Cable Standard Test Method for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable

ASTM D4566

International Telecommunications Union (ITU-T); Recommendations: G.650 G.652 G.653 G.655 G.656 Definition and Test Methods for the Relevant Parameters of Single-Mode Fibers Characteristics of Single Mode Optical Fiber Cable Characteristics of a Dispersion Shifted Single Mode Optical Fiber Cable Characteristics of a Non-Zero Dispersion Shifted Single-Mode Optical Fiber Cable Characteristics of a Fiber and Cable with Non-Zero Dispersion for Wideband Optical Transport

Electronic Industries Association EIA/TIA-455-20A EIA/TIA-455-25B EIA/TIA-455-31C EIA/TIA-455-37A EIA/TIA-455-41A EIA/TIA-455-45B EIA/TIA-455-48B Measurement of Change in Optical Transmittance Repeated Impact Testing of Fiber Optic Cables and Cable Assemblies Fiber Tensile Proof Test Method Low or High Temperature Bend Test for Fiber Optic Cable Compressive Loading Resistance of Fiber Optic Cables Method for Measuring Optical Fiber Geometry Using a Laboratory Microscope Measurements of Optical Fiber Cladding Diameter Using Laser Based Instruments

Page 3 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

EIA/TIA-455-55C EIA/TIA-455-59 EIA/TIA-455-61A EIA/TIA-455-78A EIA/TIA-455-81B EIA/TIA-455-85A EIA/TIA-455-104A EIA/TIA-455-164A EIA/TIA-455-167A EIA/TIA-455-169A EIA/TIA-455-173 EIA/TIA-455-175A

End View Methods for Measuring Coating and Buffer Geometry of Optical Fibers Measurements of Fiber Point Defects Using an OTDR Measurement of Fiber or Cable Attenuation Using an OTDR Spectral Attenuation Cutback Measurement for Single Mode Optical Fibers Compound Flow (Drip) Test for Filled Fiber Optic Cables Fiber Optic Cable Twist Test Fiber Optic Cable Cyclic Flexing Test Single Mode Fiber, Measurement of Mode Field Diameter by Far-Field Scanning Mode Field Diameter, Variable Aperture in the Far Field Chromatic Dispersion Measurement of Optical Fibers by the Phase-Shift Method Coating Geometry Measurement for Optical Fiber Side View Method Chromatic Dispersion Measurement of Single Mode Optical Fibers by the Differential Phase Shift Method Measurements of Optical Fiber Cross Sectional Geometry by the Automated Grey-Scale Analysis Numerical Aperture Measurement of Graded Index Fibers Measurements of Strip Force for Mechanically Removing Coatings from Optical Fibers Optical Fiber Cable Color Coding

EIA/TIA-455-176 EIA/TIA-455-177A EIA/TIA-455-178A EIA/TIA-598-A

International Electrotechnical Commission IEC 60793 IEC 60794 Optical Fibers, Part 2, Product Specifications Optical Fiber Cables, Part 1, Generic Specifications

Page 4 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

Definitions and Abbreviations 4.1 Definitions Multimode: A fiber that allows more than one mode to propagate. Single Mode: A fiber that supports the propagation of only one mode. Fiber Core: The central region of an optical fiber through which most of the optical power is transmitted. Cladding: one or more layers of glass surrounding the core of a fiber, which has a refractive index smaller than that of the core. Core (Cladding) Concentricity Error: The distance between the core center and the cladding center divided by the core diameter. Core (Cladding) Non-Circularity: The difference between the diameters of the circles defined by the core (cladding) tolerance field divided by the core (cladding) diameter. Chromatic Dispersion: A term used to describe the spreading of a light pulse per unit source spectrum width in an optical fiber caused by the different group velocities of the different wavelengths composing the source spectrum. Chromatic Dispersion Coefficient: The chromatic dispersion per unit source spectrum width and unit length of fiber usually expressed in ps/(nm.km). Zero-Dispersion: The slope of the chromatic dispersion coefficient versus wavelength curve at the zero dispersion wavelength. Dispersion Shifted Fiber: A fiber which has the zero dispersion wavelength in the 1550 nm wavelength region and which is optimized for use at wavelengths around 1550 nm. Dispersion Unshifted Fiber: A fiber which has the zero dispersion wavelength around the 1300 nm wavelength region and which is optimized for use at wavelengths around 1300 nm region. Zero-Dispersion Wavelength: The wavelength at which the chromatic dispersion approaches zero. Polarization Mode Dispersion (PMD): Polarization mode dispersion is the differential Group Delay time between two orthogonally polarized modes, which cause pulse spreading in digital systems and distortions in analog systems.

Page 5 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

Cut-Off Wavelength: The wavelength at which the second order LP 11 mode ceases to propagate in the fiber. Operational wavelengths longer than the cut-off wavelength propagate as single mode while operational wavelengths shorter than the cut-off wavelength propagate as multimode. Mode Field: The single-mode field distribution giving rise to a spatial intensity distribution in the fiber. Numerical Aperture: The numerical aperture (NA) is the sine of the vertex half-angle of the largest cone of rays that can enter or leave the core of an optical fiber, multiplied by the refractive index of the medium in which the vertex of the core is located. Refractive Index: Ratio of the wavelength or phase velocity of an electromagnetic wave (light) in a vacuum to that in a medium. Refractive Index profiles: The distribution of the refractive index along a diameter of an optical fiber. Primary Coating: Layer of acrylate or other material covering the fiber cladding layer. Secondary Coating: Layer of material covering the primary coating. 4.2 Abbreviations ASTM EIA/TIA RDUD IEC ITU-T C MHz-km dB dB/km HDPE MDPE American Society for Testing and Materials Electronic industries Association/Telecommunications Industry Association Rural Development Utilities Program International Electrotechnical Commission International Telecommunications Union (Telecommunications Sector) Centigrade temperature scale Megahertz-kilometer Decibel Decibels per 1 kilometer High density polyethylene Medium Density polyethylene
Page 6 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

LDHMW LLDHMW ps/(nm.km)

Low density, high molecular weight polyethylene Liner Low Density, High Molecular Weight polyethylene Picosecond per nanometer times kilometer

ps/(nm.km) Picosecond per nanometer squared times kilometer 5 Specifications 5.1 Single Mode Fiber Three types of Single Mode Fiber Optic Cables are included in this specification for use in Saudi Aramco: a) Zero-Dispersion single mode fiber which has zero-dispersion wavelength around 1310 nm and optimized for use in 1310 nm wavelength region, but also useable in the 1550 nm region. The fiber core must have either a matched or depressed clad step refractive index profile. Dispersion-Shifted single mode fiber, which has a nominal zero-dispersion wavelength, close to 1550 nm and optimized for use at wavelengths in the region between 1550 nm and 1600 nm. The fiber core must have either a segmented core design or depressed clad step refractive index profile. Non-Zero Dispersion-Shifted single mode fiber whose chromatic dispersion (absolute value) is greater than some non-zero value throughout the wavelength range of anticipated use and optimized for use at wavelengths in the region between 1550 nm and 1600 nm. Material The fiber material (core and cladding) shall be glass, covered by either an ultraviolet-cured acrylate or other suitable coating. The core glass shall be cylindrical. Other core geometry (elliptical) or special asymmetrically doped cores designed to preserve the polarization of light are not covered or allowed under this specification. All fibers shall maintain their geometrical properties for a minimum required life of 20 years. 5.1.2 Refractive Index Profile The fiber shall exhibit a step refractive index profile with the exception of dispersion-shifted and Non-Zero Dispersion Shifted fiber, which may be manufactured with a segmented core that may more closely approximate a graded refractive index.

b)

c)

5.1.1

Page 7 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.1.3

Mode Field Diameter The fiber shall exhibit a nominally circular mode field diameter as specified in Table 5.1: Table 5.1 Mode Field Diameter Specification
Fiber Type Zero-Dispersion Dispersion-Shifted Non-Zero Dispersion Shifted Wavelength 1310 nm 1550 nm 1550 nm Mode Field Diameter 8.6 - 9.5 m (10%) 7.8 - 8.5 m (10%) 8 - 11 m (10%)

Mode Field Diameter shall be measured in accordance with any one of the following test methods: a. b. c. d. EIA/TIA-455-164; EIA/TIA-455-165; EIA/TIA-455-167; or EIA/TIA-455-174.

Mode Field Concentricity Error 5.1.3.1.1 5.1.3.1.2 The mode field concentricity error at 1300 nm shall not exceed 1.0 m for Zero-Dispersion fiber. The mode field concentricity error at 1550 nm shall not exceed 1.0 m for both Dispersion-Shifted and Non-Zero Dispersion Shifted fiber. Mode field concentricity error, for all single mode fibers, shall be measured in accordance with any one of the following test methods: a. b. 5.1.4 Cladding Dispersion Unshifted fiber shall be manufactured with either a matched or depressed cladding configuration. Dispersion shifted fiber may be manufactured with a segmented core that may provide the function of cladding. EIA/TIA-455-45B; EIA/TIA-445-176.

5.1.3.1.3

Page 8 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.1.4.1

Cladding Diameter The cladding diameter shall be 125 m 2 m when measured in accordance with any one of the following test methods: a. b. c. EIA/TIA-455-45B; EIA/TIA-455-176; EIA/TIA-455-48B, Methods A or B.

5.1.4.2

Cladding Non-circularity Cladding non-circularity shall be less than 2% when measured in accordance with any one of the following test methods: a. b. EIA/TIA-455-45B; EIA/TIA-455-176.

5.1.5

Operational Wavelength Zero-Dispersion fiber shall be manufactured to operate with center wavelengths of both 1310 and 1550 nanometers, that is, be able to meet attenuation, chromatic dispersion, and zero dispersion slope and wavelength ranges for both operating wavelengths as required in the following paragraphs. Dispersion-Shifted and Non-Zero Dispersion Shifted fiber shall be optimized to operate at a center wavelength of 1550 nm.

5.1.6

Cut-Off Wavelength The fiber cut-off wavelength shall be less than 1260 nm for all types of single mode fibers when measured in accordance with EIA/TIA-455-170.

5.1.7

Center Wavelength Attenuation The attenuation characteristics of the fiber shall not exceed the values outlined in Table 5.2. Depending on user requirements, the user may specify lower attenuation values.

Page 9 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

Table 5.2 Attenuation Properties


Fiber Type Zero-Dispersion Dispersion-Shifted Non-Zero Dispersion Shifted Commentary Notes: The objective is to obtain the lowest possible attenuation. The lowest value depends on the fabrication process, fiber composition and design and cable design. For Zero-Dispersion Fibers, values in the range 0.3-0.4 dB/km in the 1310 nm region and 0.17-0.25 dB/km in the 1550 nm region is achievable. For Dispersion-Shifted and Non-Zero Dispersion Shifted Fibers, values in the range of 0.19-0.25 dB/km in the 1550 nm region is achievable. Operational Wavelength 1310 nm 1550 nm 1550 nm 1550 nm Attenuation (max) per Kilometer 0.5 dB 0.3 dB 0.3 dB 0.3 dB

The fiber attenuation measurements shall be made in accordance with any one of the following test methods: a. b. c. EIA/TIA-455-78A; EIA/TIA-455-59; or EIA/TIA-455-61. Attenuation Over Wavelength Range 5.1.7.1.1 For Zero-Dispersion fibers, the attenuation values for wavelengths in the range of 12851330 nm and 1525-1575 nm within a cable shall not exceed the attenuation at 1310 nm and 1550 nm specified in Table 5.2 by more than 0.1 dB per kilometer. For Dispersion-Shifted and Non-Zero Dispersion Shifted fibers; the attenuation values for wavelengths in the range of 15251575 nm within a cable shall not exceed the attenuation at 1550 nm specified in Table 5.2 by more than 0.1 dB per kilometer.

5.1.7.1

5.1.7.1.2

Page 10 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.1.7.1.3

The test method used for measuring the attenuation shall be in accordance with any of the methods specified in Paragraph 5.1.7.

5.1.7.2

Discontinuities Any attenuation discontinuity shall be less than 0.1 dB when measured at 1310 20 nm for Zero-Dispersion fiber, and at 1550 20 nm for Dispersion-Shifted and Non-Zero Dispersion Shifted fiber when measured in accordance with EIA/TIA-455-59.

5.1.8

Chromatic Dispersion The fiber chromatic dispersion coefficient shall not exceed the values given in Table 5.3. Depending on user requirements, the user may specify lower chromatic dispersion coefficient values. Table 5.3 Chromatic Dispersion Coefficient Specifications
Fiber Type Zero-Dispersion Dispersion-Shifted Non-Zero Dispersion Shifted Wavelength Range 1288-1339 1271-1360 1525-1575 1530-1565 Maximum Chromatic Dispersion Coefficient [ps/(nm.km] 3.5 5.3 3.5 6.0

Chromatic Dispersion Coefficient shall be measured in accordance with either of the following test methods: a. b. c. EIA/TIA-455-168A; EIA/TIA-455-169A; or EIA/TIA-455-175A. Zero-Dispersion Slope 5.1.8.1.1 For Zero-Dispersion fiber, the zero-dispersion wavelength shall be between 1295 and 1322 nanometers, and the maximum value of the dispersion slope at the zero dispersion wavelength shall not be greater than 0.092 ps/(nm.km) when-measured in accordance with any one of the methods specified in Paragraph 5.1.8.
Page 11 of 38

5.1.8.1

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.1.8.1.2

For Dispersion-Shifted and Non-Zero Dispersion Shifted fibers, the zero-dispersion wavelength shall be between 1525 and 1575 nanometers, and the maximum value of the dispersion slope at the zero dispersion wavelength shall not be greater than 0.085 ps/(nm.km) when measured in accordance with any one of the test procedures specified in Paragraph 5.1.8.

5.1.8.2

Polarization mode dispersion coefficient PMD Coefficient is presently under study in ITU-T. All single mode fiber optic cable is recommended to have a PMD coefficient below 0.5 ps/km(1/2). This corresponds to a PMD-limited transmission distance of about 400 km for STM-64 systems.
Commentary Note: Systems with lower bit rate distance requirement can tolerate higher values of PMD coefficient without any impairment.

5.2

Multimode Fiber 5.2.1 Material The fiber material shall be glass. The core glass shall be cylindrical. Other core geometry (elliptical) or special asymmetrically doped cores designed to preserve the polarization of light are not allowed under this specification. All fibers shall maintain their geometrical properties for a minimum required life of 20 years. 5.2.2 Refractive Index Profile The fiber shall exhibit a graded (parabolic) refractive index profile. 5.2.3 Core Diameter The fiber shall exhibit a nominally circular core as specified in Table 5.4:

Page 12 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

Table 5.4 Core Diameter Specifications


Wavelength 850 nm 1300 nm Core Diameter (m) 62.5 3.0 m 62.5 3.0 m

Core Diameter shall be measured in accordance with any one of the following test methods: a. b. 5.2.4 EIA/TIA-455-58A; or EIA/TIA-455-176.

Core Non-circularity The core non-circularity of multimode fibers shall not exceed 6% when measured in accordance with any one of the following test methods: a. b. EIA/TIA-455-45B; or EIA/TIA-445-176.

5.2.5

Cladding Diameter The cladding diameter shall be 125 2 m when measured in accordance with any one of the following test methods: a. b. c. EIA/TIA-455-45B; EIA/TIA-455-176; or EIA/TIA-455-48B, Methods A or B.

5.2.6

Cladding Non-circularity Cladding non-circularity shall be less than 2% when measured in accordance with any one of the following test methods: a. b. EIA/TIA-455-45A; EIA/TIA-455-176.

5.2.7

Attenuation The attenuation characteristics of the fiber shall not exceed the values outlined in Table 5.5. Depending on user requirements, the user may specify lower attenuation values.

Page 13 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

Table 5.5 Attenuation Specifications


Fiber Type Multimode 62.5/125 Multimode 62.5/125 Operational Wavelength 850 nm 1300 nm Maximum Value per kilometer 3.5 dB 1.5 dB

The fiber attenuation measurements shall be made in accordance with any one of the following test methods: a. b. c. 5.2.8 EIA/TIA-455-46A; EIA/TIA-455-53A; or EIA/TIA-455-61.

Discontinuities Any attenuation discontinuity in the fiber length shall be less than 0.2 dB at 1300 20 nm when measured in accordance with EIA/TIA-45559.

5.2.9

Bandwidth The bandwidth of the multimode fibers at the -3 dB optical power of the optical fibers shall be within the ranges given in Table 5.6. Table 5.6 Multimode Bandwidth Specifications
Fiber Type Multimode 62.5/125 Multimode 62.5/125 Wavelength Range (nm) 850 1300 Bandwidth Range [MHz-km] 100-200 200-800

When measured in accordance with either of the following test methods: a. b. 5.2.10 EIA/TIA-455-30B; or EIA/TIA-455-51A.

Numerical Aperture The numerical aperture for each multimode fiber in the cable shall be 0.275 0.015 when measured in accordance with EIA/TIA-455-177A.

Page 14 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.3

Primary Coating The optical fiber shall be coated with a suitable material to preserve the intrinsic strength of the glass and protect the fiber. The protective material shall be free from holes, splits, blisters and other imperfections and shall be as smooth and concentric as is consistent with the best commercial practice. 5.3.1 Coating Diameter The primary coating shall be 250 15 m in diameter when measured in accordance with either EIA/TIA-455-55B or EIA/TIA 455-173. 5.3.2 Coating Material The primary coating material shall consist of a heat or ultra violet cured acrylic or silicone material compatible with all the components and materials of the cable. The primary coating material shall be continuous throughout a single length of fiber and of the same material. 5.3.3 Coating Removal The primary coating shall be easily removable without damage to the fiber. The maximum force require to mechanically remove 25 mm of protective fiber coating shall not exceed 13 Newton when measured in accordance with EIA/TIA-455-178A. If chemicals are required to soften the coating they shall be non-toxic and dermatologically safe. 5.3.4 Shrinkback Shrinkback testing shall be performed in accordance with ASTM D4565, Paragraph 14.1, using a talc bed at a temperature of 95C. Shrinkback shall not exceed 5% of the original 150 mm length of the specimen. The total shrinkage of the specimen must be measured.

5.4

Secondary Coating A fiber secondary coating is optional for fibers contained in loose tube or slotted core assemblies. Fibers contained in tight buffer cable assemblies are required to have a secondary coating. 5.4.1 Coating Diameter The secondary coating shall have a diameter in the range of 250 to 900 m when measured in accordance with either EIA/TIA-455-55B or EIA/TIA-455-173.
Page 15 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.4.2

Coating Material Materials used for the secondary coatings on fibers shall protect the primary coating and fiber from exposure to water and the free OH-ion. Materials use for the secondary coating shall compatible with all the components and materials of the cable. The secondary coating material shall be continuous throughout a single length of fiber and of the same material.

5.4.3

Coating Removal The secondary coating shall be easily removable without damage to the fiber. If chemicals are required to soften the coating they shall be nontoxic and dermatologically safe.

5.5

Fiber Tensile Strength The individual coated fibers shall be proof tested prior to cabling at a minimum tensile stress of 0.35 gigapascal (50,000 psi) when measured in accordance with either EIA/TIA-455-31C or IEC 793 Part 2.

5.6

Allowed Splices Factory splices of fibers are allowed provided that: a. b. c. d. any attenuation discontinuity introduced does not exceed the value given in paragraphs 5.1.7.2 and 5.2.8; maximum attenuation values for the completed cable do not exceed the values stated in Table 5.2 and Table 5.5; no more than one splice occurs in any one fiber in any 10 kilometer segment of finished cable; and a record of all fiber splice locations within a cable is delivered with each cable.

5.7

Fiber Containment 5.7.1 Allowable Types Fibers may be contained by a loose tube, a slotted core, or a tight buffered technique that provides the overall cable with the required level of fiber tensile strain relief, micro bending resistance, crush resistance, flexibility, and water blocking required in paragraphs below. No more than twelve (12) fibers shall be placed in any one tube or slot.

Page 16 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.7.2

Fiber Color Codes/Indexing When more than one fiber is contained in a loose tube or slotted core (Reference Paragraph 5.7.1), then each individual fiber within a tube or slot shall be uniquely color coded for the full length of the cable. When a single fiber is contained in a loose tube or slot, then, the tube or slot color code or indexing method shall allow unique identification of each fiber. 5.7.2.1 Each individual fiber in a tight-buffered cable shall be uniquely color-coded for the full length of the cable. The color-coding scheme shall remain constant for a given cable type, from any single manufacturer, from cable to cable. (The standards of colors and color-coding for fiber and buffer tube shall be in accordance with RDUP PE 90 Section 4). Fiber and Buffer Tube Identification The colors designated for identification of loose buffer tubes, tight tube buffer fibers and individual fibers in multifiber tubes, slots or bundles are shown in the following table:
Buffer Tube & Fiber No. c. d. e. f. g. h. i. j. k. l. m. n. o. p. q. Color Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua Blue/Black Tracer Orange/Black Tracer Green/Black Tracer

5.7.2.2

Page 17 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode) Buffer Tube & Fiber No. r. s. t. u. v. w. x. y. z Color Brown/Black Tracer Slate/Black Tracer White/Black Tracer Red/Black Tracer Black/Yellow Tracer Yellow/Black Tracer Violet/Black Tracer Rose/Black Tracer Aqua/Black Tracer

5.7.2.3

Standards of Color Except for the aqua color, the colors of fibers and tubes supplied in accordance with this specification are specified in terms of the Munsell Color System (ASTM D1535 - 89) and must comply with the color limits as defined in EIA/TIA-598-A.
Commentary Note: A visual color standard meeting these requirements and entitled "Munsell Color Charts for Color Coding," may be obtained from the Munsell Color Company, Inc., 2441 North Calvert Street, Baltimore, Maryland 21218. The latest edition of the color standard should be used.

5.7.2.4

The aqua color limits using the Munsell Color System must be as follows:
Munsell Notation Symbol Centered H++ H-V++ V-C++ C-Aqua Color 10BG 7/6 5B 7/6 5BG 7/6 10BG 8/4 10BG 6/6 None 1-BG 7/4

Page 18 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode) Commentary Note: Any other coloring scheme used for identification of buffer tubes and optical fibers will not be accepted.

5.7.2.5

Loose Tube Containment When more than one loose tube containing fibers is used within a cable and each individual fiber within the cable is not uniquely color-coded, then the tubes shall be uniquely color coded or indexed for the entire length of the cable such that tubes can be positively identified at any point in the cable.

5.7.2.6

Slotted Core Containment If fibers are contained in slots and each individual fiber within the cable is not uniquely color coded, then the slots shall be indexed by coloring two adjacent slots, skipping a slot, and coloring a third slot to provide positive slot and rotation identification for the full length of the cable.

5.7.2.7

Tight Buffered Containment Tight-buffered fibers shall be individually color coded as specified in paragraph 5.7.2.

5.7.3

Geometry of Arrangement Fiber containment shall be arranged so as to produce an overall cylindrical cable shape. Non-metallic solid rods or strips may be used to fill voids to achieve the overall desired geometry. Wrapping material such as tape or thread may be used as core binding to secure loose tubes into the required position during manufacture. Wrapping material shall be applied to slotted rod containment to secure fibers in position. Core binders shall be non-hygroscopic and non-wicking dielectric material.

5.7.4

Filling The interior of loose tubes containing fibers shall be filled with a suitable material to prevent water penetration and to provide cushion to the fibers. All interstices surrounding loose tubes, slotted rod, and filler rods or strips shall be filled with a suitable material to prevent water penetration. Filling material is not required for tight-buffered cables. The filling material or solvents required to remove the filling
Page 19 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

material shall not pose any health hazard and shall be dermatologically safe. 5.8 Cable Strength Member 5.8.1 Sheath type strength members shall be manufactured from aramid cords or similar non-conductive, high tensile strength, high Young's modulus and low elongation material. Central strength members shall be fiberglass, or any other non-metallic alternative material. Strength members may be incorporated into the cable core as a central support member or filler, as fillers between the fiber containment members, as an annular serving over the cable core, as an annular serving over the intermediate jacket, as an annular serving between a tight buffered secondary coating and sub-cable jacket, embedded in the outer jacket, or as a combination of any of these methods. Cable sections containing spliced strength members shall meet the same physical requirements as unspliced cable sections.

5.8.2 5.8.3

5.8.4 5.9

Inner Sheath An inner sheath is required for loose tube or slotted core direct burial cable and is optional for duct cable or tight-buffered direct burial cable. 5.9.1 Thickness The inner sheath thickness shall have a nominal value of 1.2 mm. The average thickness at any cross section shall not be less than 90% of the nominal thickness. The minimum spot thickness shall not be less than 80% of the nominal thickness. 5.9.2 Material 5.9.2.1 Direct Burial Cable The material for direct burial cables shall be as specified in Paragraph 5.11.1, with the exception that either black or natural polyethylene may be used. In the case of natural polyethylene, the requirements for absorption coefficient and the inclusion of furnace black are waived.

Page 20 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.9.2.2

Duct Cable 5.9.2.2.1 For non-plenum or non-riser rated cable, the optional inner sheath for duct cable shall use one of the materials specified in Paragraph 5.11.1. In the case of a duct cable requiring a plenum or riser fire rating, the inner sheath material shall be one of the following: a. b. c. d. e. f. flame retarding PVC; flame retarding polyurethane; high temperature plenum fluoropolymer; hytrel; Teflon PFA; or Teflon FEP.

5.9.2.2.2

5.9.3

Minor defects in the inner sheath (defects having a dimension of 3 mm or less in any direction) may be repaired by means of heat fusing in accordance with good commercial practices using sheath grade compounds.

5.10

Moisture Barrier A metallic moisture barrier is optional and shall be specified by the end user depending on cable application requirements. If specified, then it must meet the following requirements: 5.10.1 5.10.2 5.10.3 The metallic moisture barrier shall be aluminum tape and be electrically conductive for the full length of the cable. The tape shall be applied longitudinally with a minimum overlap of 3 mm and bonded (sealed). The aluminum tape shall comply with the requirements for Type 1, Class I tape as described in ASTM B736 or be a minimum of 0.175 mm thick and coated on both sides with a polymer film. The aluminum tape shall be bonded to the inner sheath to form a moisture barrier sheath. All joints in the aluminum tape shall be welded. Any section of tape containing a joint shall have a breaking strength not less than 80% of non-jointed tape. The electrical resistance of a 1-meter tape section
Page 21 of 38

5.10.4 5.10.5

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

containing a joint shall not exceed 110% of an equivalent length without a joint. The area of the joint shall be re-coated with polymer, on both sides of the tape. No more than two joints are permitted per 500-meter length of cable. The joints shall have the same resistance to water penetration as non-jointed tape. 5.11 Armor Metallic armor is not required for direct burial or duct cables. (Refer to SAES-T-624 for requirements). For special applications, if specified, then the metallic armor shall meet the following requirements; 5.11.1 Material Armor material shall be electrolytically chrome-plated steel, stainless steel, or stainless steel/copper laminate. 5.11.2 Thickness Armor thickness shall be 0.15 mm +10/-0%. 5.11.3 Bonding Armor shall be bonded to itself either by a lap joint with adhesive material or by welding. If a lap joint is used then the overlap shall be greater than 3 mm. Armor shall be bonded to the outer sheath. 5.11.4 Filling All interstices between the armor and inner sheath shall be filled with a material that meets the requirements of Paragraph 5.12 to exclude water in cables that use loose tubes, or slotted core fiber containment techniques. Filling material is not required for tight-buffered cables. 5.11.5 Electrical Properties Armor shall be continuous and electrically conductive for the entire length of the cable. 5.11.6 Splices Any I kilometer section of cable shall not contain more than one splice in the armor. Splicing techniques shall preserve the electrical properties specified in paragraph 5.10.5.

Page 22 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.11.7

Armor Repair Repairs to the armor shall not be permitted.

5.12

Outer Sheath The outer sheath shall provide the cable with a tough, flexible, protective covering, which can withstand exposure to sunlight, to temperatures and to stresses reasonably expected in normal installation and service. The outer sheath for duct type cables shall conform to the requirements of Paragraph 5.11.1 through 5.11.1.7 below. 5.12.1 Material The raw material used for the outer jacket of direct buried cable or non-plenum/non-riser rated duct cable shall be one of the five types listed in Paragraphs 5.11.1.1 through 5.11.1.5. The raw material shall contain an antioxidant to provide long-term stabilization and the materials shall contain a 2.60 0.25% concentration of furnace black to provide ultraviolet shielding. The raw material supplier shall compound both the antioxidant and furnace black into the material. 5.12.1.1 Low-density high molecular weight polyethylene (LDHMW) shall conform to the requirements of ASTM D1248, Type 1, Class C, Category 4 or 5, Grade J3. Low-density high molecular weight ethylene copolymer (LDHMW) shall conform to the requirements of ASTM D1248, Type I, Class C, Category 4 or 5, Grade J3. Linear low-density high molecular weight polyethylene (LLDHMW) shall-conform to the requirements of ASTM D1248, Type I, Class C, Category 4 or 5, Grade J3. High-density polyethylene (HD) shall conform to the requirements of ASTM D1248, Type III, Class C, Category 4 or 5, Grade J4. Medium-density polyethylene (MD) shall conform to the requirements of ASTM D1248, Type II, Class C, Category 4 or 5, Grade J4. The average particle size of the carbon black shall be less than 20 m.

5.12.1.2

5.12.1.3

5.12.1.4

5.12.1.5

5.12.1.6

Page 23 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.12.1.7 5.12.1.8

The outer sheath shall display an absorption coefficient greater than 400. The material used for the outer sheath for riser or plenum rated duct cable shall be one of the types specified in Paragraph 5.8.2.2.2 and shall meet the requirements of Paragraphs 5.11.2 and 5.11.3.

5.12.2

Thickness The outer sheath thickness shall be no less than 1.6 +O/-0.4 mm for both direct buried and duct cables. The minimum spot thickness shall not be less than so percent of the nominal thickness.

5.12.3

Eccentricity The eccentricity of the outer sheath shall not exceed 40%.

5.12.4 5.12.5

The outer sheath material removed from or tested on the cable shall be capable of meeting the requirements of Table 5.7. Testing Procedures The procedures for testing jacket specimens for compliance with paragraph 5.12.4 shall be as follows; 5.12.5.1 Melt Flow Rate The melt flow rate shall comply with ASTM D1238; Condition E. Jacketing material shall be free from flooding and filling compound. 5.12.5.2 Tensile strength and Ultimate Elongation Test in accordance with ASTM D4565, using a jaw separation speed of 500 mm per minute for low-density material and 50 mm per minute for high and medium density materials. 5.12.5.3 Environmental Stress Cracking Test in accordance with ASTM D4565. 5.12.5.4 Shrinkback Test in accordance with the procedures specified in ASTM D4565 using a temperature of 100 1C for low
Page 24 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

density material and a test temperature of 115 1C for high and medium density materials. Table 5.7 Outer Sheath Material Properties
Property Melt Flow Rate Percent increase from raw material, Maximum <0.41 (Initial Melt Index) 0.41-2.00 (Initial Melt Index) Tensile Strength Minimum, MPa Ultimate Elongation Minimum Percent Environmental Stress Cracking Maximum Failures Shrinkback Maximum, Percent Impact Maximum, Failures LLDHMW Ethylene Copolymer 100 50 LDHMW PE 50 HD or MD PE 50

12 400 0/10 5 2/10

12 400 2/10 5 2/10

16.5 300 2/10 5 2/10

5.12.5.5

Impact The test shall be performed in accordance with ASTM D4565 using an impact force of 4 Newton-meters at a temperature of -20 2C. A cracked or split jacket constitutes failure.

5.13

Filling Compound 5.13.1 Type The filling compound shall be a synthetic cable filling compound suitable for use in tropical climates. It shall be neutral in color. 5.13.2 Drop Point The drop point when measured in accordance with the test method of ASTM D566 shall be at least 85C. 5.13.3 Flash Point The flash point when measured in accordance with the test method of ASTM D92 shall be at least 200C.

Page 25 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

5.13.4

Total Acid Value The permissible value of acid when tested in accordance with ASTM D974 shall be no more than the equivalent of 0.1 mg of potassium hydroxide per gram of filling compound.

5.13.5

Compatibility The filling compound shall be compatible with the primary coating, the loose tubes or slotted core and all other components or materials of the cable which it may contact and shall not affect the long term stability of any of the other cable components.

5.13.6

Health Hazard Filling material used or solvents required to remove the filling material shall not pose any health hazard and shall be dermatologically safe.

5.13.7 5.13.8 5.14

The compound shall allow free movement of the fiber in the tube or slot. The filling compound shall not be silicon based.

Completed Cable 5.14.1 Bend Radius during Installation All cable supplied in compliance with this specification shall be capable of bending to a radius of 20 times the outer sheath diameter while under the maximum installation tension requirement stated in Paragraph 5.13.4 without sustaining any damage to any cable component and without degrading the 20 year life expectancy of the cable. 5.14.2 Installed Bend Radius All cable supplied in compliance with this specification shall be capable of being bent to a radius of 10 times the outer sheath diameter under no tension. The cable shall be capable of withstanding an installed bend radius of 10 times the outer sheath diameter without sustaining any damage to any cable component and without degrading the optical characteristics over the 20-year life expectancy of the cable. 5.14.3 Tensile Strength Direct burial cable shall withstand application of a tensile force greater than 2000 Newton with no degradation of the optical or mechanical
Page 26 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

properties of the cable. Duct cable shall withstand application of a tensile force of 1000 Newton with no degradation of the optical or mechanical properties of the cable. 5.14.4 Crush Direct burial cable shall withstand application of a 440 N/cm load with no degradation of the optical or mechanical properties of the cable. Duct cable shall withstand the application of a 220 N/cm load with no degradation of the optical or mechanical properties of the cable. 5.14.5 Marking Each fiber cable shall be marked on the outer jacket, with the following information in high contrast letters no less than 3 mm in height: a. Continuous sequentially numbered length markers at intervals of not more than 2 m with an accuracy of +1/-0% of actual cable length; Optical Cable, OC, Optical Fiber Cable, or OF; Number of fibers.

b. c. 5.14.6

Environmental Requirements All cable supplied in compliance with this specification shall be capable of withstanding the environmental conditions stated below for a minimum period of 20 years without detriment to the transmission or operation and maintenance characteristics of the cable.

5.14.7

Temperature Direct buried and duct cables must be capable of being installed and operated with the temperature between -30 and +70C.

5.15

Cable Lengths 5.15.1 Manufacturers shall be capable of supplying direct burial cable in uninterrupted lengths of not less than 3 km, and duct cable in uninterrupted lengths of not less than 2 km. Manufacturer to specify other available standard cable length reels. Pulling Eyes All specified duct cable shall be capable of being field fitted with a pulling eye. Manufacturer shall provide instructions for field fitting a

5.15.2

Page 27 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

pulling eye. 5.16 Cable Reels The cable shall be shipped on non-returnable reels. Each length of cable shall be wound on a separate cable reel. Saudi Aramco shall specify the actual cable length per reel. The reels shall be so constructed as to prevent damage during shipment and handling during installation. Duct cable reels shall be provided with cable pulling eyes. 5.16.1 Diameter The diameter of drum shall be large enough to prevent damage to the cable from reeling and unreeling. 5.16.2 Arbor Hole size The arbor hole shall admit a spindle 63.5 mm in diameter without binding. 5.16.3 Wrapping and Packing 5.16.3.1 The outer end of the cable shall be securely fastened to prevent the cable from coming loose during transit. The inner end of the cable shall project through a slot in the flange of the reel, around an inner riser, or into a recess on the reel flange near the drum and be fastened in such a way to prevent the cable from becoming loose during installation. Battens shall be fastened across the inside edges of the reel flange to protect the exposed cable during transit. Spikes, staples or other fastening devices must be used in a manner, which will not result in penetration of the cable. Each reel shall be plainly marked to indicate the direction in which it should be rolled to prevent loosening of the cable on the reel. Each reel must be stenciled or lettered with the name of the manufacturer 5.16.3.3 The following information must be either stenciled on the reel or on a tag firmly attached to the reel: a. OPTICAL CABLE (Single mode Zero Dispersion/Dispersion Shifted/Non-Zero Dispersion Shifted, Multimode)
Page 28 of 38

5.16.3.2

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

b. c. d. e. f. g. h. i. 6 Testing and Inspection

Number of Fibers Armored or Non-Armored Year of Manufacturer Length of Cable Reel Number The corresponding Saudi Aramco SAMSS and Revision date Name of cable manufacturer Manufacturer part number

These tests are intended for qualification of initial cable designs and major modifications of "accepted" designs. What constitutes a "major" modification is at the discretion of Consulting Services Department (CSD) of Saudi Aramco. These tests are intended to show the inherent capability of the manufacturer to produce cable products that have satisfactory performance characteristics, long life and long-term optical stability but are not intended as field tests.
Commentary Note: All fiber-optic cables should be purchased from the approved list of Saudi Aramco vendors only (RVL-Regulated vendor list). Certificate of compliance to Saudi Aramco standards and requirements from a reputable testing agency and a Factory Acceptance Test (FAT) by qualified Saudi Aramco personnel is required to be an approved Saudi Aramco vendor.

Testing standards and procedures other than those specifically referenced by this specification may be allowed if accepted by Saudi Aramco. Justification for substitution of alternate testing standards/procedures and a statement of the standards/procedures to be used for cable qualification shall be provided to Saudi Aramco for approval. 6.1 Initial Acceptance For initial acceptance, the manufacturer must submit: a. b. c. d. An original signature certification that the product fully complies with each section of this specification; Provide certified Qualification Test data; A set of instructions for handling the cable; Material Safety Data Sheets for all components; and

Page 29 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

e. 6.2

Agree to periodic plant inspections.

Cable Tests and Technical Data Requirements The following tests and technical data are required for 100% of completed cable. 6.2.1 6.2.2 The armor (if provided) for each length of cable shall be tested for continuity using the procedures of ASTM D4566. The attenuation of each optical fiber of each finished cable shall be measured according to one of the procedures listed in Paragraphs 5.1.7 or 5.2.7, and a record of the test results shall be delivered to the procuring agency for each delivered cable reel. Optical discontinuities shall be isolated and their location and amplitude recorded. The record shall be delivered to the procuring agency with the cable for each fiber in each cable. A cross-sectional diagram of each cable showing fiber counts, cable dimensions and materials, and manufacturers part number shall be provided.

6.2.3

6.2.4

6.3

Capability Tests Tests on a quality assurance basis shall be made as frequently as is required by the manufacturer to determine and maintain compliance with requirements such as the following: a. b. c. d. e. f. g. h. i. j. k. Cut off wavelength per Paragraph 5.1.6; Chromatic dispersion per Paragraph 5.1.8; Bandwidth per Paragraph 5.2.9; Adhesion properties of the protective fiber coating per Paragraph 5.4.3; Dielectric strength between metallic members in the cable per Paragraph 5.7.3; Requirements for inner sheath materials per Paragraphs 5.8.2 and 5.8.3; Properties of the coated moisture barrier material per Paragraph 5.9; Properties of the armor material per Paragraph 5.10; Requirements for outer sheath materials per Paragraph 5.11.1.6 through 5.11.5.5; Requirements for filling compounds per Paragraph 5.12; Cable bend requirements/test per Paragraphs 5.13.1, 5.13.2 and 6.5.2;
Page 30 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

l. m. n. o. p. q. r. 6.4

Sequential marking and lettering per Paragraph 5.13.6; Water penetration, sheath slip, and temperature tests per Paragraphs 6.5.7 through 6.5.13; Compound flow test per Paragraph 6.5.1; Cable impact test per Paragraph 5.11.5.5 or 6.5.3; Cable compression test per Paragraph 6.5.4; Cable twist test per Paragraph 6.5.5; and Cable flex test per Paragraph 6.5.6.

Records of Optical and Physical Tests Each manufacturer shall maintain suitable records for a period of at least 3 years of all optical and physical tests required by this specification on completed cable as set forth in Paragraph 6.3. The test data for a particular reel shall be in a form that it may be readily available to Saudi Aramco upon request. The optical data shall be furnished to the purchasing agency on a suitable and easily readable form.

6.5

Qualification Test Methods The following test procedures are for qualification tests not previously described in this standard. 6.5.1 Compound Flow Test (Flooded Designs only, Not applicable to tight buffered cables): a. Three (3) each 300 mm long test samples shall be preconditioned for 24 hours at 23 5C and then tested in accordance with EIA/TIA-455-81A using a test temperature of 80 1C. The amount of filling or flooding compounds that flowed or dripped from any of the suspended cable specimens shall be less than or equal to 0.5 grams of material. The measurement of an amount greater than 0.5 grams for any of the suspended cable specimens shall constitute a failure.

b.

c. 6.5.2

Cable Bend Test All cables manufactured in accordance with the requirements of this specification shall be capable of meeting the following bend test without exhibiting an increase in fiber attenuation greater than 0.10 dB for single mode fiber and 0.40 for multimode fiber:
Page 31 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

a.

Measure the attenuation of Zero-dispersion fibers at 1310 20 and 1550 20 manometers; and, the attenuation of dispersion shifted and Non-Zero dispersion shifted fibers at 1550 20 nanometers. After measuring the attenuation of the optical fibers, test the cable sample in accordance with EIA/TIA-445-37A, Test Condition E and Turns Test Level 3. The following detailed test conditions shall apply: 1) 2) Section 4.2 - Mandrel diameter shall be 20 times the cable diameter. Section 4.5 - Measure the attenuation increase of the wound sample at the test temperature and specified wavelengths in accordance with EIA/TIA-455-20A. For armored cable, the armor overlap shall be on the outside of the bend. For self-supporting cable, the jacketed support messenger and connection web shall be removed prior to testing.

b.

c.

3) 4) d.

The cable may be allowed to warm-up to room temperature before visual inspection. The bent area of the cable shall not show visible evidence of fracture of the jacket, delamination of the armor bond at the overlap (armored cable only) or a separation of the armor to the outer sheath (armored cable only).

6.5.3

Cable Impact Test All cables manufactured in accordance with the requirements of this specification shall be capable of meeting one of the following impact tests with an increase in fiber attenuation of less than 0.10 dB for single mode fiber and 0.40 for multimode fiber from the measured attenuation value, and without cracking or splitting of the cable sheath. 6.5.3.1 Option One a. b. 6.5.3.2 Measure the attenuation of the optical fibers in accordance with Paragraph 6.5.2.b. After measuring the attenuation of the optical fibers, test the cable in accordance with EIA/TIA-455-25A.

Option Two a. Cable shall be tested according to IEC 794-1-E4.


Page 32 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

b. c. d. 6.5.4

The mass of the weight shall be 2 kg and the height shall be one (1) m. The increase in attenuation shall be less than 0.1 dB at 1550 nm and 1310 nm. There shall be no damage to any of the cable components.

Cable Compression Test All cables manufactured in accordance with the requirements of this specification, shall be capable of meeting one of the following compressive strength tests with an increase in fiber attenuation of less than 0.10 dB for single mode fiber and 0.40 for multimode fiber from the measured attenuation value, and without cracking or splitting of the cable when subjected to a minimum compressive load of 440 N/cm for direct buried cable, and 220 N/cm for duct cable. 6.5.4.1 Option One a. b. Measure the attenuation of the optical fibers in accordance with Paragraph 6.5.2.b. After measuring the attenuation of the-optical fibers, test the cable in accordance with EIA/TIA-455-41A using a rate of 5 mm per minute and maintaining the load for 15 minutes.

6.5.4.2

Option Two a. b. Cable shall be tested according to IEC 794-1-E3. A load of 440 N/cm shall be gradually applied and maintained for a period of two hours for direct buried cable. A load of 220 N/cm shall be gradually applied and maintained for a period of ten minutes for duct cable.

c. 6.5.5

Cable Twist Test All cables manufactured in accordance with the requirements of this specification shall be capable of meeting the following twist test with an increase in fiber attenuation of less than 0.10 dB for single mode fiber and 0.40 for multimode fiber of the measured value, and without cracking or splitting of the cable sheath.

Page 33 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

a. b.

Measure the attenuation of the optical fibers in accordance with Paragraph 6.5.2.b. After measuring the attenuation of the optical fibers, test the cable in accordance with EIA/TIA-455-85A, using a maximum cable twisting length of 4 meters.

6.5.6

Cable Flex Test All cables manufactured in accordance with the requirements of this specification shall be capable of meeting the following flex test with an increase in fiber attenuation of less than 0.10 dB for single mode fiber and 0.40 for multimode fiber of the measured value: a. b. Measure the attenuation of the optical fibers in accordance with Paragraph 6.5.2.b. After measuring the attenuation of the optical fibers, test the cable in accordance with EIA/TIA-455-104A, Test conditions I and II, flexed for 25 cycles using a sheave diameter not less than 20 times the cable diameter (Test condition letter B). After completion of the test, the bent area of the cable shall not show visible evidence of fracture of the jacket, delamination of the armor bond at the overlap (armored cable only) or a separation of the armor to the outer jacket lamination in nonflooded cable (armored cable only). After removal of the outer sheath, there shall be no visible evidence of fracture of the armor, when present, and of the components in the core.

c.

d.

6.5.7

Tests Requiring Temperature Pre-Conditioning a. b. c. d. All testing shall be performed on lengths removed sequentially from a given cable manufacturing "run". The cable samples shall not have been exposed to temperatures in excess of 38C since their initial cool downs after sheathing. Unless otherwise specified, all measurement shall be made at 23 5C. The following sample types will be used for testing. Specified sample lengths are minimum lengths: 1. Sample A: This fiber cable sample shall have a minimum length of 500 1 m. Coil the sample with a diameter of 15
Page 34 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

to 20 times its sheath diameter. Three (3) samples are required. 2. 3. 6.5.8 Sample B: This fiber cable sample shall have a minimum length of one (1) m. Four (4) samples are required. Sample C: This fiber cable sample shall have a minimum length of 600 mm. Four (4) samples are required.

Heat Aging Test 6.5.8.1 Test Samples Place one sample of each type of samples specified in Paragraph 6.5.7.d in an oven or environmental chamber. The ends of Sample A shall exit from the chamber or oven to enable performance of optical properties tests. Securely seal the oven exit holes. 6.5.8.2 Sequence of Tests The samples are to be subjected to the following tests after conditioning: a. Water Penetration Test outlined in Paragraph 6.5.9. (Flooded Designs only - Not applicable to tightbuffered cables) Jacket Slip Strength Test outlined in Paragraph 6.5.10 (Flooded Designs only - Not applicable to tight buffered cables)

b.

6.5.8.3

Sample A Initial Measurements At a temperature of 23 5C, measure and record the attenuation for: Zero-dispersion single mode fibers at 1310 nm and 1550 nm; and, for Dispersion shifted and Non-Zero dispersion shifted single mode fibers at 1550 nm and/or multimode fibers at 850 nm and 1300 nm.

6.5.8.4

Heat Conditioning 6.5.8.4.1 Immediately after completing Sample A initial measurements, condition all sample type specimens for 14 days at a temperature of 70 2C.

Page 35 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

6.5.8.4.2

At the end of this period note any exudation of cable filler (if applicable). Measure the parameters given in Paragraph 6.5.8.3 and record the data.

6.5.8.5

Overall Optical Deviation Calculate the change in all parameter measurements between the final parameters (after conditioning) with the initial parameters. The attenuation of each fiber shall not change by more than 0.1 dB/km.

6.5.9

Water Penetration Testing (Flooded Design only - Not for tight buffered cables) 6.5.9.1 A watertight closure shall be placed over the outer sheath of one end of a fiber cable Sample specimen. The closure shall not be placed over the sheath so tightly that the flow of water through pre-existing voids or air spaces is restricted. The other end of the sample shall remain open. Test water penetration as per one of the following options: a. Option A 1. 2. Weigh the sample and closure prior to testing. Fill the closure with water and place under a continuous pressure of 10 0.7 KPa for one hour. Collect the water leakage from the end of the test sample during the test and weigh to the nearest 0.1 g. Immediately after the one-hour test, seal the ends of the cable with a thin layer of grease and remove all visible water from the closure, being careful not to remove water that penetrated into the core during the test. Re-weigh the sample and determine the weight of water that penetrated into the core.

6.5.9.2

3.

4.

5. b.

Option B 1. Fill the closure with a 0.2 g sodium fluorescein


Page 36 of 38

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

per liter water solution and apply a continuous pressure of 10 0.7 KPa for one hour. 2. 3. Catch and weigh any water that leaks from the end of the cable during the one-hour period. If no water leaks from the sample, carefully remove the water from the closure. Then, carefully remove, one at a time, the outer jacket, armor (if present), inner jacket (if present), and core wrap examining each component with an ultraviolet light source for water penetration. After removal of the core wrap, carefully dissect the core and examine for water penetration within the-core. Where water penetration is observed, measure the penetration distance.

4.

5. 6.5.10

Jacket Slip Strength Test (Flooded designs only - Not for tight buffered cables) 6.5.10.1 6.5.10.2 6.5.10.3 Sample Selection: Use fiber cable Sample C specimen for this test. Sample Preparation: Prepare test sample in accordance with the procedures specified in ASTM D4565. Sample Conditioning and Testing: 1. 2. 3. Remove the sample from the tensile tester prior to testing and condition for one hour at 50 2C. Test immediately in accordance with the procedures specified in ASTM D4565. A minimum Jacket slip strength of 67 Newton is required. Record the load attained.

6.5.11

Temperature and Humidity Exposure 6.5.11.1 Repeat steps 6.5.8.3 through 6.5.8.5 for a separate set of samples A, B, and C which have not been subjected to the heat conditioning of Paragraph 6.5.8.4. Immediately after completing the measurements expose the test sample to 100-temperature cycling. Relative humidity
Page 37 of 38

6.5.11.2

Document Responsibility: Communications Standards Committee 18-SAMSS-625 Issue Date: 6 November 2010 Outside Plant Fiber Optic Cable Next Planned Update: 6 November 2015 Specifications (Single Mode & Multiple Mode)

within the chamber shall be maintained at 90 2%. One cycle consists of: a. b. c. d. 6.5.11.3 6.5.12 Beginning at a stabilized chamber and a test sample temperature of 52 2C; Increasing the temperature to 57 2C; Allowing the chamber and test samples to stabilize at this level; and, Dropping the temperature back to 52 2C.

Repeat steps of Paragraphs 6.5.8.4.2 through 6.5.10.3.

Temperature Cycling 6.5.12.1 Repeat steps 6.5.8.3 through 6.5.8.5 for a separate set of samples A, B, and C which have not been subjected to the heat conditioning of Paragraph 6.5.8.4. Immediately after completing the measurements, subject the test sample to 10 cycles of temperature between -30C and + 70C. The test sample must be held at each temperature extreme for a minimum of 1- hours during each cycle of temperature. The air within the temperature cycling chamber must be circulated throughout the duration of the cycling. Repeat steps of Paragraphs 6.5.8.4.2 through 6.5.10.3.

6.5.12.2

6.5.13

Control Sample 6.5.13.1 A separate set of fiber cable lengths for samples B and C shall have been maintained at 23 5C for at least 48 hours before the testing. Repeat steps of Paragraphs 6.5.9 through 6.5.10.3 for these samples.

6.5.13.2

6 November 2010

Revision Summary Revised the "Next Planned Update." Reaffirmed the contents of the document, and reissued with editorial changes.

Page 38 of 38