Energy Modeling and Simulation

Trust Commitment Customer Focus

The Less you Burn, the more you Earn

Introduction
ENERGY MODELING SERVICES OFFERED
Energy Modelling, Simulation & Lighting Analysis for the various establishment i.e. Commercial, Residential & Industrial Buildings etc. as per international standards (i.e. ASHRAE 90.1), local authority regulation & as per clients requirements. Review of existing buildings, HVAC Systems, lighting etc. & savings in Proposed design up to 0-60% better than Code. Comparison of Existing & New Proposed Systems with respect to Baseline Appendix-G ASHRAE 90.1.
Continue...
Software eQuest 3.64, DiaLux , COMcheck & AutoCAD | Team 3 |
2

Introduction

Technical assistance to reduce Energy Consumption in the buildings. To Qualify the building for EPACT Certification using eQuest. Compare energy consumption, energy demand, Utility bills for existing & Proposed building performances against Appendix-G ASHRAE 90.1. Interior, Exterior & Day Lighting Reports for Existing & Proposed Design. Software Used for energy modelling : eQuest 3.64, DiaLux, COMcheck & AutoCAD.

Software eQuest 3.64, DiaLux , COMcheck & AutoCAD | Team 3 |

Departmental Store

Energy Modeling in eQuest 3.64


Project Type: Departmental Store in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

Departmental Store

Lighting Analysis

Project Type: Departmental Store in USA Inputs Site Photos. PDF of Tentative Architectural Layout of Interior & Exterior. Output Tentative CAD Architectural Layout. Foot Candle Analysis of Existing Interior & Exterior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior & Exterior Lighting Design. CAD Layout of Proposed Lighting Design. Compliance Report of Proposed Lighting System i.e. As per ASHARE 90.1, IECC etc.

Software DiaLux & ComCheck | Team 1 | Duration 5 Days

Dining Facility

Energy Modeling in eQuest 3.64

Project Type: Dinning Facility in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

Dining Facility

Lighting Analysis

Project Type: Dinning Facility in USA Inputs Architectural Layout. Existing Lighting PDF Layout. Output Foot Candle Analysis of Existing Interior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior Lighting Design. CAD Layout of Proposed Lighting Design.

Compliance Report of Proposed Lighting System i.e. As per ASHARE 90.1, IECC etc.

Software DiaLux & ComCheck | Team 1 | Duration 5 Days

Dining Facility

Lighting Analysis

Project Type: Dinning Facility in USA Inputs Site Location. Door & Window Schedule. Output Day Light Calculation.

Software DiaLux & ComCheck | Team 1 | Duration 5 Days

Dinning Facility

Energy Modeling in eQuest 3.64

Project Type: Dinning Facility in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

Dining Facility

Lighting Analysis

Project Type: Dinning Facility in USA Inputs Architectural Layout. Existing Lighting PDF Layout. Output Foot Candle Analysis of Existing Interior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior Lighting Design. CAD Layout of Proposed Lighting Design.

Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc.

Software DiaLux & ComCheck | Team 1 | Duration 5 Days

10

Dining Facility

Lighting Analysis

Project Type: Dinning Facility in USA Inputs Site Location. Door & Window Schedule. Output Day Light Calculation.

Software DiaLux | Team 1 | Duration 2 Days

11

Commercial Building

Energy Modeling in eQuest 3.64

Project Type: Commercial building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

12

Commercial Building

Lighting Analysis

Project Type: Commercial Building in USA Inputs Architectural Layout. Existing Lighting PDF Layout. Output Foot Candle Analysis of Existing Interior Lighting Design. CAD Layout of Existing Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc. Foot Candle Analysis of Proposed Interior Lighting Design. CAD Layout of Proposed Lighting Design. Compliance Report of Existing Lighting System i.e. As per ASHARE 90.1, IECC etc.

Software DiaLux & ComCheck | Team 1 | Duration 5 Days

13

Commercial Building

Lighting Analysis

Project Type: Commercial Building in USA Inputs Site Location. Door & Window Schedule. Output Day Light Calculation.

Software DiaLux | Team 1 | Duration 2 Days

14

Office Building

Energy Modeling in eQuest 3.64

Project Type: Office Building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & Proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

15

Warehouse Building

Energy Modeling in eQuest 3.64

Project Type : Warehouse building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & Proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

16

Industrial Building

Energy Modeling in eQuest 3.64

Project Type : Industrial Building in USA Scope of Work: 1. To compare Baseline building as per ASHRAE 90.1 Appendix G to Proposed Building & Existing building performance. 2. To Propose efficient HVAC systems for Proposed design 3. To qualify Building for EPACT certification Inputs 1. Existing & Proposed CAD Civil, Mechanical & Electrical layouts 2. Comchech Report comparing lighting. 3. Building Usage Information 4. Existing building Utility Bills Output 1. Monthly & Annual Energy Consumption by End use 2. Monthly Utility Bills 3. Monthly & annual Peak demand by End use 4. Monthly Electric Peak Day load Profiles

Software eQuest 3.64 | Team 1 | Duration 5 Days

17

Contact us
Engineering
(Sales & Marketing Division)
Email:

info@truecadd.com

Phone: +91 79 4000 3252 Board: +91 79 4000 3000 Fax: +91 79 4000 3202

Website: www.truecadd.com