You are on page 1of 7

Vertical Can Pumps

WWW.V-FLO.COM

TEL:+8610 88580010/20/30 FAX:+8610 88580150

V-FLO

Rm A-205 Ziyunxuang Building No.81 Zizhuyuan Rd. Haidian Dist. Beijing China

Vertical can pumps


API 610 (6th edition) ASME-code VIII+IX

Specification
Sizes Capacities Heads Operating Press. Operating Temp. DN 40 up to 200mm Q up to 800m3/h H up to 800m P up to 10.0Mpa t -180~+180

WWW.CHANGCHA.COM

Application ranges
For pumping clean or slightly polluted, cold or hot, chemically neutral or aggressive liquids. in refineries in chemical and petrochemical plants in energy plants in cryogenic engineering in cryogenic engineering in pipelines in offshore industry in transport of liquefied gas

Construction
Multistage, radially split, vertical can pumps with stage casings and singlesuction, radial impellers. Impeller 1st stage is always a suction impeller, inducer is possible. Balance of axial thrust by antifriction bearings, in case of higher difference pressure axial thrust is compensated by a balance piston/liner. The cans is only subject to suction pressure, the installation depth and the length of the can depend on NPSH conditions. Same design without can is possible for installation in existing vessels or for installation with flanged connection (see design alternatives). The bearings of the motor lantern are oil-lubricated antifriction bearings with rotation independent automatic lubrication by internal oil circulation. A hydro-dynamic radial plain bearing is on the suction side of the pump. In case of extreme installation depths with liquid-lubricated intermediate bearing. Shaft sealed by packed stuffing box or mechanical seal (single, double or tandem seals). Connections for cooling, Flushing or sealing liquid. Suction and discharge branches are arranged at 180 (inline) above the mounting flange. Other branch positions are possible. Flanges according to DIN or GB, auxiliary connections have GRC/R threads. Drive by flanged motor via flexible coupling (spacer or non-spacer coupling). Direction of rotation anticlockwise seen from driven end.

Performance Ranges

V-FLO
2

WWW.V-FLO.COM

TEL:+8610 88580010/20/30 FAX:+8610 88580150

V-FLO

Rm A-205 Ziyunxuang Building No.81 Zizhuyuan Rd. Haidian Dist. Beijing China

Characteristic
Driven by vertical standard motors simple commissioning, maintenance and replacement of spares high efficiencies, reliable operation no axial thrust transmission to motor Bearings Magnets with high energy density high-quality Samarium Cobalt (SmCo) or Neodyme Iron Boron (NdFeB) compact installation suitable for high and low temperatures hermetically sealed inner magnets Early warning system direct mounted PT 100 temperature monitor fluid detector in the magnetic coupling chamber critical conditions indicated immediately Vertical suction can design simple pipework adaptable to NPSH requirements minimum space due to vertical placement Replaceable stationary and rotating wear rings special material combinations for high wear resistance, long service life improved efficiency over the complete pump service life securely locked with radial pins Material options for a wide range of applications wetted parts in steel, chromium steel, CrNiMo steels, special combinations available on request API material classes S1, S6, C6 and A8 Dry running prevention Electronic devices can be supplied to protect the pump from a variety of extreme operating conditions Containment Shell fewer eddy currents, higher strength

WWW.CHANGCHA.COM

Built-in safety stop collar with a gap narrower than the gap between outer rotor and containment shell if the motor bearing fails there is no contact of the outer magnets with the containment shell pump remains sealed Efficient cooling-lubricating system product circulation from discharge via a magnetic filter, flowing through the drive chamber and returning via the hollow shaft to a pressurized area to avoid vaporization prevents heating by eddy currents in the containment shell self-venting suction can avoids venting during startup Hydrodynamic radial bearing made of proven material combinations, wear resistant product lubricated, resistant to chemicals Safe axial thrust compensation operates as a hydrostatic axial bearing cavitation protection by re-circulation of the balance flow to the pressure after suction stage

The lift-off device

It was the development of the lift-off device that made possible the introduction of a vertically suspended pump with magnetic coupling and balance disk. The device ensures a gap between the balancing elements whether the pump is running or not. Metallic contact and premature wear are avoided. Working principle: When at rest, the rotor weight is supported by the magnet force between the inner and outer magnets to avoid contact between the axial balancing disk and sleeve during startup and shutdown. During startup, the axial load increases and eventually overcomes the axial holding force of the device. At that time the balancing disk gap reduces until it self compensates for the axial load. During operation, the balancing disk continues to self compensate for any load changes and maintains a steady rotor position for improved wear life. During shutdown, the axial load reduces as speed reduces and the device overcomes the load and acts to separate the distance between the balance disk and sleeve. Operating successfully on light gravity hydrocarbons and other low lubricity fluids without external thrust bearings,

Safety Plus - Secondary Sealing

less heating, higher performance density minimized losses

A secondary sealing safety feature is built in. This eliminates the possibility of leakage of fluid to the atmosphere and the consequence of damage to the environment. For this purpose a maintenancefree, dry-running gas seal is mounted between the magnetic coupling and the motor. The coupling is sealed by static seals, designed for the maximum allowable pump pressure and monitored by a pressure switch. If the pump pressure leaks into this space an alarm is triggered shutting the pump down.

V-FLO
3

WWW.V-FLO.COM

TEL:+8610 88580010/20/30 FAX:+8610 88580150

V-FLO

Rm A-205 Ziyunxuang Building No.81 Zizhuyuan Rd. Haidian Dist. Beijing China

Construction Drawings

WWW.CHANGCHA.COM

The Standard of the Suction & Discharge Press.


Flange Suc. Dis. TTMC40 DIN2635 DIN2637 TTMC50 DIN2635 DIN2637 TTMC80 DIN2635 DIN2637 TTMC100 DIN2635 DIN2637 TTMC125 DIN2635 DIN2637 TTMC150 TTMC200 GB9115.10-88 GB9115.10-88 GB9115.11-88 GB9115.11-88

Materials
Model TTMC40 TTMC50 TTMC80 TTMC100 TTMC125 TTMC150 dk 32 38 42 48 55 60 75 0Cr17Ni7A1 0.066 0.115 0.159 0.249 0.390 0.518 1.085 3Cr13 0.034 0.066 0.093 0.145 0.226 0.302 0.631

V-FLO
4

TTMC200

WWW.V-FLO.COM

TEL:+8610 88580010/20/30 FAX:+8610 88580150

V-FLO

Rm A-205 Ziyunxuang Building No.81 Zizhuyuan Rd. Haidian Dist. Beijing China

Foundation Dimensions

WWW.CHANGCHA.COM

Model TTMC40 TTMC50 TTMC80 TTMC100 TTMC125 TTMC150 TTMC200

Dimensions t>0 a 800 850 920 1000 1150 1300 1400 b 560 620 700 750 900 1000 1100 c 60 60 65 65 75 75 75 h 140 140 160 160 200 200 200 n1 500 560 640 680 840 940 1040 n2 360 380 400 450 500 500 600 G M24 M24 M24 M24 M30 M30 M30 A 470 520 580 630 790 900 1000 S 700 750 820 900 1050 1200 1300 t 500 560 640 680 840 940 1040 m 100 100 100 100 100 100 100 u 370 370 370 370 370 370 370 v 900 950 1020 1100 1250 1400 1500 MdxL M24x400 M24x400 M24x400 M24x400 M24x400 M24x400
WWW.V-FLO.COM

M24x400

Model TTMC40 TTMC50 TTMC80 TTMC100 TTMC125 TTMC150 TTMC200

Dimensions t 0 a 1000 1150 1300 1400 1500 1600 1700 b 750 900 1000 1100 1200 1300 1400 c 65 75 75 75 75 75 75 h 160 200 200 200 200 200 200 n1 680 840 940 1040 1140 1240 1340 n2 450 500 500 600 700 800 900 G M24 M24 M24 M24 M30 M30 M30 A 630 790 900 1000 1100 1200 1300

S 900 1050 1200 1300 1400 1500 1600

t 680 840 940 1040 1140 1240 1340

m 100 100 100 100 100 100 100

u 370 370 370 370 370 370 370

v 1100 1250 1400 1500 1600 1700 1800

MdxL M24x400 M24x400 M24x400 M24x400 M24x400 M24x400 M24x400

V-FLO
5

TEL:+8610 88580010/20/30 FAX:+8610 88580150

V-FLO

Rm A-205 Ziyunxuang Building No.81 Zizhuyuan Rd. Haidian Dist. Beijing China

Installation Drawings & Dimensions


Model DN DNs DND Installation Dimensions d5 K 535 760 985 1210 1435 1660 1885 2110 2335 2560 608 828 1048 1268 1488 1708 1928 2148 2368 515 775 1035 1295 1555 1815 2075 2335 555 795 1035 1275 1515 1755 1995 2235 2475 650 980 1310 1640 1970 2300 2630 2960 815 1095 1375 1655 1935 2215 2495 2775 3055 3335 725 1115 1455 1795 2135 2475 2815 3155

No. Stages A 2-9 2-14 B 2-9 2-14 C 2-9 2-14 c

Overall Dimensions f g h n y

WWW.CHANGCHA.COM

TTMC40

80

40

406

TTMC50

100

510

457

TTMC80

150

80

508

TTMC100 150

100

558

T 755 980 1205 1430 1655 1880 2105 2330 2555 2780 858 1078 1298 1518 1738 1958 2178 2398 2618 785 1045 1305 1565 1825 2085 2345 2605 855 1095 1335 1575 1815 2055 2295 2535 2775 1000 1330 1660 1990 2320 2650 2980 3310 1240 1520 1800 2080 2360 2640 2920 3200 3480 3760 1275 1615 1955 2295 2635 2975 3315 3655

2-17 2-27

2-15

45

325

190

834

560

180

2-8 2-12 2-13

2-8 2-12

2-8

2-13 2-16

2-10

35

375

207

900

620

180

2-6 2-10 2-14

2-6

2-6

2-10 2-15

2-8

45

400

250

1020

700

250

2-5 2-8 2-11

2-5

2-5

2-8

2-7

45

450

250

1040

750

250

1-4

TTMC125 200

125

711

1-7

55

550

310

1260

900

250

1.Measuring suction side 2.Measuring discharge side 3.Measuring balance piston 4.Sealing/flushing 5.Vent 6.Drain-pump 7.Drain-can 8.Leakage drain 9.Flushing 10.Cooling water-inlet 11.Cooling water-outlet 12.Oil-filling 13.Oil drain 14.Oil level indicator

TTMC150 300

150

813

1-4

50

600

365

1440 1000 300

1-4 1-6 50 1-7 650 445 1685 1100 300

TTMC200 400

200

914

V-FLO
6

WWW.V-FLO.COM

TEL:+8610 88580010/20/30 FAX:+8610 88580150

V-FLO

Rm A-205 Ziyunxuang Building No.81 Zizhuyuan Rd. Haidian Dist. Beijing China

Design Alternatives

WWW.CHANGCHA.COM

Installation Mode

V-FLO
7

WWW.V-FLO.COM