You are on page 1of 4

PCP-RIFTS Min&GenDataSets.DRAFT.20050901.Posted.

xls General & Minimum Data Sets (8/4/2011)

C-FER Technologies

PCP-RIFTS: General Data Set PCP-RIFTS: Minimum Data Set (1)


Parameter
Field Information
Company Name Division Name Field Name Field Location (Country) Location of PCP Supply Centre Location of PCP Teardown Facility Field Type (Onshore/Offshore) Oil Density at STP Reservoir Temperature Dead Oil Viscosity at STP Oil Bubble Point Pressure Well Name Well Type (Geometry) Wellhead location Pad or Platform Name Reservoir Name/Zone Reservoir Type Reservoir Recovery Mechanism Completion Type Sand Control Type Production Casing Outer Diameter Production Period Number Date Installed (mm/dd/yyyy) Date Period Started (mm/dd/yyyy) Period Status Date Period Ended (mm/dd/yyyy) Date Pulled (mm/dd/yyyy) Actual Runtime

Description
Name of operating company (Participant) Name of operating unit, group of field, etc. Name of oil field Name of country field is in Country, Provinces/State, and nearest Town/City of source of PCP system. If more than one supply centre, please provide location of main supply centre. Country, Province/State, and nearest Town/City where pulled PCPs are sent for teardown and inspection. If more than one teardown facility, please provide location of main teardown facility. Onshore, Offshore (Platform), Offshore (Subsea), Onshore/Offshore Oil density inAPI at standard temperature (15C) and pressure (1 atm) Fluid temperature at the reservoir conditions Dead oil viscosity at standard temperature (15C) and pressure (1 atm) Bubble point (vapour) pressure of oil at Reservoir Temperature Name or identifier of well Vertical, Slant, Deviated, Horizontal, Sidetracked, Re-Entry Sidetrack, or Multilateral Onshore, Platform, Subsea Name of group of wells Name(s) of producing reservoirs (during production period) Carbonate, Consolidated Sandstone, Unconsolidated Sandstone, Evaporite Aquifer drive, Solution Gas Drive, Water flood, EOR (e.g., CO2 flooding, Water-Alternating-Gas (WAG), Polymer Flood, Steam stimulation, etc) Perforated Casing, Open hole, or Unknown Type of sand control installed in the well during the production period, e.g. Gravel Pack, Slotted Liner, Wirewrapped Screen, etc. If no sand control installed, please indicate None. Nominal outer diameter of the production casing Production period number for well Date PCP system was installed Date PCP system was first started. If not provided, the Date Period Started will be assumed equal to the Date Installed. Status of the production period: Period Completed or Still on Production. Date PCP system failed, was shutdown, or last date record was updated if PCP still running. If not provided, the Date Period Ended will be assumed equal to the Date Pulled. Date PCP system was pulled Days the PCP system was actually running. If not provided, Actual Runtime will be assumed equal to Duration Did/has the PCP system failed (Yes or No)? This parameter should be consistent with the Period Status. If Period Status = "Still Running", then PCP System Failed? should be "No". If PCP System Failed? = "Yes", then Period Status should be "Period Completed". General category of why the PCP was pulled More specific reason why the PCP was pulled Only required if both PCP and Tubing System failed. If only one system fails, then the Primary Failed System is defaulted to that system. The primary failed PCP component or part The primary descriptor of the PCP System - Primary Failed Item The secondary descriptor of the PCP System - Primary Failed Item Circumstances during design, manufacture or use that led to the PCP System failure Specific circumstances during design, manufacture or use that led to the PCP System failure Circumstances during design, manufacture or use that contributed to the PCP System failure Specific circumstances during design, manufacture or use that contributed to the PCP System failure Did/has the Tubing System failed? The primary failed Tubing component or part The primary descriptor of the Tubing System - Primary Failed Item The secondary descriptor of the Tubing System - Primary Failed Item Circumstances during design, manufacture or use that led to the Tubing System failure Specific circumstances during design, manufacture or use that led to the Tubing System failure Circumstances during design, manufacture or use that contributed to the Tubing System failure Specific circumstances during design, manufacture or use that contributed to the Tubing System failure Specific notes regarding the failure. Include a description of the "contaminant" (e.g., sand, scale, asphaltene, etc.) if the Contaminated failure descriptor is used. Type of control panel: Switchboard, Switchboard with Soft Start, Variable Frequency Drive Vendor of control panel Type of power transmission: Belts and Sheaves, Gears, Combination, or Other Type of prime mover: Electric Motor, Internal Combustion Engine, or Hydraulic Motor. Name of vendor/manufacturer of surface drivehead Rated power of prime mover on surface drive Local Power Line/Grid, Field Generator, Wellsite Generator Excellent, Good, Average, Low, Poor

Fluid Information

Well Information

Runtime Data (dates)

Failure a u e Information o at o (as per PCP Failure Nomenclature Standard)

PCP System Failed? y Reason for Pull: General Reason for Pull: Specific Primary Failed System PCP System - Primary Failed Item PCP System - Primary Failure Descriptor PCP System - Secondary Failure Descriptor PCP System - Failure Cause: General PCP System - Failure Cause: Specific PCP System - Contributing Cause: General PCP System - Contributing Cause: Specific Tubing System Failed? Tubing System - Primary Failed Item Tubing System - Primary Failure Descriptor Tubing System - Secondary Failure Descriptor Tubing System - Failure Cause: General Tubing System - Failure Cause: Specific Tubing System - Contributing Cause: General Tubing System - Contributing Cause: Specific Failure Comments

Surface Equipment Data

Control Panel Type Control Panel Vendor

IF Rod Driven PCP Power Transmission Type Prime Mover Type System
Drivehead Vendor Prime Mover Rated Power Power Source Power Quality

Confidential

1/4

PCP-RIFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011)

C-FER Technologies

PCP-RIFTS: General Data Set PCP-RIFTS: Minimum Data Set (1)


Parameter
Downhole Equipment Data
PCP Vendor Pump Model (SI) Elastomer Model Elastomer Type Rotor Coating Type Pump Rated Displacement Pump Rated Differential Pressure Stator Serial Number Rotor Serial Number In-Test: Date In-Test: Speed In-Test: Reference Differential Pressure In-Test: Volumetric Efficiency at Reference DP In-Test: Friction Torque In-Test: Volumetric Efficiency at Zero DP Out-Test: Date Out-Test: Speed Out-Test: Reference Differential Pressure Out-Test: Volumetric Efficiency at Reference DP Out-Test: Friction Torque Out-Test: Volumetric Efficiency at Zero DP Date Pump Inspected Stator New/Used/Repaired Rotor New/Used/Rechromed Stator Pull Condition Rotor Pull Condition Pump Intake Vendor Pump Intake Type Pump Intake Pull Condition Tag g Bar Type yp Tag Bar Pull Condition Pump Seating Depth MD Pump Seating Depth TVD Inclination at PSD Maximum Dogleg Tubing Outer Diameter Tubing Weight Tubing Internal Coating Type IF Rod Driven PCP Rod Diameter Rod Material Grade System Rod Type Rod Centralizer Type Rod Guide Type Tubing Anchor Installed? Tubing Anchor Model Tubing Rotator Installed? Tubing Rotator Vendor Tubing Rotator Model Gearbox Vendor IF DH Drive PCP Gearbox Model System Gearbox Gear Ratio Gearbox Trim Gearbox Serial Number(s) Gearbox New/Used/Repaired Gearbox Pull Condition Seal Vendor Seal Model Seal Trim Seal Serial Number(s) Seal New/Used/Repaired Seal Pull Condition Motor Vendor Motor Model Motor Rated Power @ 60Hz Motor Trim Motor Serial Number(s)

Description
Name of vendor/manufacturer of pump components (e.g., Weatherford BMW). If rotor vendor and stator vendor are different, use the stator vendor as the Pump Vendor. Catalogue model designation of pump (e.g., 15-1400) Model designation of stator elastomer Type of stator elastomer (e.g., medium nitrile, high nitrile, fluroelastomer, etc.) Type of rotor coating (e.g. chrome, boron, etc.) Rated displacement of the pump Rated differential pressure of the pump Serial number or unique identifiers for that specific PCP stator Serial number or unique identifiers for that specific PC P rotor Date pump was bench tested prior to installation Rotational speed pump was bench tested at (RPM) prior to installation Reference pressure of bench test volumetric efficiency (usually rated pressure) prior to installation Volumetric efficiency of pump at reference pressure and test speed prior to installation Friction torque of pump at test speed prior to installation Volumetric efficiency of pump at zero differential pressure prior to installation Date pump was bench tested after pull Rotational speed pump was bench tested at (RPM) after pull Reference pressure of bench test volumetric efficiency (usually rated pressure) after pull Volumetric efficiency of pump at reference pressure and test speed after pull Friction torque of pump at test speed after pull Volumetric efficiency of pump at zero differential pressure after pull Date pump was inspected When installed, was the stator New or Used (without service or minor servicing only) When installed, was the rotor New, Used (without service or minor servicing only), Repaired (used and serviced), or Rechromed Condition of stator when pulled: Reusable or Not Reusable Condition of rotor when pulled: Reusable or Not Reusable Name of vendor/manufacturer of pump intake Type of pump intake: None (PCP Opening), Tail Pipe, Standard Bolt-on Intake (Flexshaft), Static Gas Separator, Bottom-Feeder Gas Separator, Multiple Stator Intakes, Rotary Gas Separator, or Gas Handler Condition of pump intake when pulled: Reusable or Not Reusable Type of pump tag bar (e.g., integral bar or plate or separate downhole component) Condition of tag bar when pulled: Reusable or Not Reusable Measured depth of the pump intake Vertical depth of the pump intake Inclination (hole angle) at the Pump Seating Depth Maximum curvature that the PCP had to pass through during installation Nominal outer diameter of production tubing Weight of the production tubing Coating type on ID of production tubing string, if tubing ID is coated Nominal diameter of rod string Material grade of rod string Type of rod string: Standard, Continuous, or Hollow Type of rod string coupling centralizers, if used (Coated, Spin Thru) Type of rod string rod body guides, if used Was a device installed to anchor the tubing to the casing? Model designation of torque anchor. Alternatively, torque anchor vendor may be provided. Was a device installed to rotate the tubing? Name of vendor/manufacturer of tubing rotator components Model designation of tubing rotator Name of vendor/manufacturer of gearbox Catalogue model designation of gearbox Gear ratio of gearbox (e.g., 9:1) Metallurgy, elastomers and coatings Serial number(s) or unique identifiers for that specific gearbox When installed, was the gearbox New, Used (without service or minor servicing only), or Repaired (used and serviced) Condition of downhole gearbox when pulled: Reusable or Not Reusable Name of vendor/manufacturer of seal components Catalogue model designation of seal (e.g. LSBSB-HL) Metallurgy, elastomers and coatings Serial number(s) or unique identifiers for that specific seal When installed, was the seal New, Used (without service or minor servicing only), or Repaired (used and serviced) Condition of downhole seal when pulled: Reusable or Not Reusable Name of vendor/manufacturer of motor Catalogue model designation of motor (e.g. KMH) Rated horsepower of motor at 60 Hz Metallurgy, elastomers and coatings Serial number(s) or unique identifiers for that specific motor

Confidential

2/4

PCP-RIFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011)

C-FER Technologies

PCP-RIFTS: General Data Set PCP-RIFTS: Minimum Data Set (1)


Parameter
Motor New/Used/Repaired Motor Pull Condition Flexshaft Vendor Flexshaft Model Flexshaft Trim Flexshaft Serial Number(s) Flexshaft New/Used/Repaired Flexshaft Pull Condition Cable Vendor Cable Model Cable Size Cable Armour Cable Serial Number(s) Motor Lead Extension (MLE) Model Cable New/Used/Repaired Cable System Pull Condition Wellhead Penetrator Model Packer Penetrator Model Downhole Monitoring System Installed? Downhole Monitoring System Vendor Downhole Monitoring System New/Used/Repaired Downhole Monitoring System Pull Condition Injection Tubing String Outer Diameter Shroud Installed? Shroud Outer Diameter Packer Installed? Packer Depth Top Landed At Y-tool Installed? Number PCP Systems in Well PCP System Configuration (Single/Tandem/Parallel) PCP Deployment Method First PCP System Installed Well? Equipment Comments

Description
When installed, was the motor New, Used (without service or minor servicing only), or Repaired (used and serviced) Condition of downhole motor when pulled: Reusable or Not Reusable Name of vendor/manufacturer of flexshaft components Catalogue model designation of flexshaft Metallurgy, elastomers and coatings Serial number(s) or unique identifiers for that specific flexshaft When installed, was the flexshaft New, Used (without service or minor servicing only), or Repaired (used and serviced) Condition of flexshaft when pulled: Reusable or Not Reusable Name of vendor/manufacturer of cable Catalogue model designation of cable (e.g., Redalead or CELF) American Wire Gauge (AWG) size of the cable Galvanized, Monel, Stainless Steel, etc. Serial number(s) or unique identifiers for that specific cable Model designation of motor lead extension (MLE) When installed, was the cable New, Used (without service or minor servicing only), or Repaired (used and serviced) Condition of cable system when pulled: Reusable or Not Reusable Model designation of wellhead penetrator. Alternatively, wellhead penetrator vendor may be provided. Model designation of packer penetrator. Alternatively, packer penetrator vendor may be provided. Was a downhole monitoring system installed with the PCP system? (Yes/No) When installed, was the downhole monitoring system New, Used (without service or minor servicing only), or Repaired (used and serviced) Condition of downhole monitoring system when pulled: Reusable or Not Reusable Nominal outer diameter of injection tubing string Was a shroud installed with the PCP system? (Yes/No) Outer diameter of shroud. If a shroud is not installed, then leave <blank>. Was a packer installed with the PCP system? (Yes/No) Measured depth to the top of the packer. If a packer is not installed, then leave <blank>. Was a Y-Tool installed with the PCP system? (Yes/No) Number of complete PCP Systems (Motor-Seal-Intake-Pump) installed in the well If there were/are more than one PCP Systems installed, where they installed in parallel or in series (charge pump)? Method used to install/deploy the PCP: Production Tbg, Coiled Tbg, Cable Was/is this PCP installation the first PCP installed in this well?

Confidential

3/4

PCP-RIFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011)

C-FER Technologies

PCP-RIFTS: General Data Set PCP-RIFTS: Minimum Data Set (1)


Parameter
Operating and Production Data
Total Flow Rate Pump Speed Torque at Drive Water Cut Pump Intake Pressure Producing Fluid Level Free Gas at Pump Intake Wellhead Pressure Casing Head Pressure Pump Intake Temperature Reservoir Static Pressure Gas Oil Ratio (GOR) Sand Cut Total Solids Concentration Scale? Asphaltenes? Solids? CO2 (% by Volume) H2S (% by Volume) Water pH Water Salinity Emulsion? Motor Operating Frequency Motor Operating Voltage Motor Operating Current Hydraulic Pressure Number of Restarts During Period Injection Fluid Injection Fluid Rate Production Period Comments Any written or verbal procedure, practices associated with design design, procurement procurement, manufacture, transportation, inspection, installation, operating, pulling and/or failure analysis. PCP Surveillance System (SCADA/Operator/Other) Automatic or Manual Control?

Description
Total Flow Rate of produced liquids at standard conditions Pump rotational speed (RPM) Measured torque on the polished rod for surface drive or at motor for downhole drive Water flow rate by %volume of produced liquids. Alternatively, produced oil and water rates may be provided. Producing pressure at the pump intake Measured depth to top of annular fluid level Free gas % by volume at the pump intake pressure and temperature (includes both separated gas and gas handled by the pump). Pressure of produced fluids at the wellhead Pressure in the casing annulus at the wellhead Producing fluid temperature at the pump intake. If not provided, Pump Intake Temperature will be assumed equal to the Reservoir Temperature. Static or shut-in pressure at the pump intake Producing gas-oil ratio. Alternatively, produced gas rate at standard conditions may be provided. Concentration of produced sand by %volume of produced liquids and solids. Alternatively, produced sand rate may be provided. If no sand was produced, please enter zero. Total concentration of solids (including sand, scale, particulate, etc.) Presence and relative severity of sale (None/Light/Moderate/Severe)4 Presence and relative severity of asphaltenes (None/ Light/Moderate/Severe)4 Presence and severity of all solids, including sand: None, Yes-Present, Light, Moderate, or Severe4 Concentration of CO2 (preference by %volume of gas). If no CO2 observed, enter zero. Concentration of H2S (preference by %volume of gas). If no H2S observed, enter zero. Acidity of produced water - tends to be indication of corrosivity Chloride concentration - indication of water density and corrosivity Presence and relative severity of emulsion problem? (None/Light/Moderate/Severe)4 Average frequency (Hz) of power supply to motor; IF surface electric or downhole drive Average voltage of power supply to motor, IF surface electric or downhole drive Average current of power supply to motor, IF surface electric or downhole drive Average pressure to the hydraulic motor, IF surface electric is a hydraulic drive Total number of starts during the production period Type of injection fluid, if used (water, diluent, oil) Daily rate of injection fluid, if used Corrosion Treatments, etc. E.g., Pump selection and design (elastomer, target in-test efficiency), startup, speed changes, inspection, discard guidelines

Practices

Number General Data Set Parameters = 188 Number Minimum Data Set Parameters = 70
Notes: 1. Parameters in the Minimum Data Set are highlighted in yellow. Click on buttons labeled "1" and "2" in top left corner of spreadsheet to
flip between Minimum and General Data Sets, respectively (or filter the parameter list based on column "A"). 2. Duration is the days between Date Period Started and Date Period Ended . Time In Hole is the days between Date Pulled and Date Installed . 3. In PCP-RIFTS, the ESPCP Cable is considered to be a system comprised of the main power cable (insulation, armor, and conductor), MLE, pothead, splices, packer penetrators, and wellhead penetrator. If any one of these parts is considered Not Reusable, the Cable System is considered Not Reusable. 4. None: substance or problem not observed. Yes - Present: substance or problem is present but the concentration/severity is unknown. Light: substance or problem observed but in small amount and not believed to be a problem for ESPs. Moderate: moderate amounts of substance or problem observed, may be or has occasionally been a problem. Severe: substantial amounts of substance or problem observed, strongly believed or known to be a problem.