You are on page 1of 6

OCEAN

COOLING TOWER

STANDARD MODEL ( YC SERIES ) BUILD IN PIPING TYPE ( YC B SERIES ) COMPACT DESIGN TYPE ( YC H SERIES )

Space Saving Easy Installation Easy Maintenance Save Installation Cost

YC-B Series ( Build in Piping Type)

Hot Water Basin


Design to complete with cover in order to prevent algue growth and ingress of foreign materials such as falling leaves into the system

Fan Drive System


To Provide enclosed FRP Pulley cover to prevent moistures entering to Fan drive system.

Hot Water Inlet/Outlet Pipes


To design inlet pipes at bottom level, easy for flow balancing, services and maintenances, saving piping & installations cost.

Gank walk
The gank walk on top of the water basin for cleaning ,lubrication and maintenances.

SPECIFICATION FOR YC B SERIES ( BUILD IN PIPING )


MODEL ITEM
Cooling Capacity Heat Rejection Water Flow Rate Air Flow Rate
RT Kcal/hr /min m3/min
oC oC oC

ONE CELLS
YC100B YC125B YC150B YC175B YC200B YC225B YC250B YC275B YC300B

100 390000 1300 630

125 487500 1625 800

Capacity

Hot Water Temp. Cold Water Temp. Wet Bulb Temp. Width ( W ) Length ( L ) Height ( H )

Overall Dimension

mm mm mm

1650 3650

Casing / Basin Steel Structure Filler

Material

Distribution Tray Bolt & Nuts Louvers Fan Type Diameters Number of Blades Fan Speed ( Rpm ) Drive System Type Power Source Rated Output ( kW ) Drive System

Fan

1400 x 1 450 550

Motor

2.2 x 1

Distribution System
Hot Water Inlet Cold Water Outlet Drain Pipe Over Flow Pipe Float Valve Make up

Piping Dimension

Make Up Weight Noise Level

Evaporation Loss Drift Loss Dry Weight Operating Weight Measuring ( W ) Measuring ( L )

mm mm mm mm mm mm (%) (%) Kg Kg
dBA dBA
(1) (2) (3) (4) (5)

80 x 2 150 x 1

1050 2210 52 46
Available for

1080 2270 57 51

200 225 250 275 300 780000 877500 975000 1072500 1170000 2600 2925 3250 3575 3900 1285 1460 1660 1540 1980 37 32 27 2000 2300 2600 4000 4300 4400 3250 FRP Hot Dip Galvanized Steel PVC FRP Hot Dip Galvanized Steel PVC Fan Blade : FRP , HUB = Aluminium Alloy AXIAL FLOW 1600 x 1 1800 x 1 2000 x 1 FOUR 380 430 450 360 380 430 Fan Belts Drives TEFC IP55 3Phase / 415V / 50Hz / 400V / 60Hz 3.7 x 1 5.5 x 1 7.5 x 1 One By Open Gravity 100 x 2 125 x 2 150 x 1 200 x 1 50 x 1 50 x 1 25 x 1 40 x 1 25 x 1 40 x 1 0.83 0.01 1150 1160 1290 1560 1600 1610 1620 2380 2420 2780 3220 3300 3350 3400 55 59 57 55 57 58 59 49 53 52 52 53 54 55
July 2006

150 585000 1950 900

175 682500 2275 1135

NOTE :

YC S.S Stainless Steel Type YCB H Build In Piping & Compact Design Type YC H Compact Design Type Above four cells and other configuration, please contact local agents Rated output motor and piping sizes varies depending on circulation water flow rate and temperature Nominal Cooling Capacity is base on 13 / min / RT ( 1RT = 3,900 Kcal / hr ) at 37oCHW.32oCCW and 27oCWB Data and specification are subject to be changed without prior notice

Page 1

SPECIFICATION FOR YC B SERIES ( BUILD IN PIPING )


MODEL ITEM
Cooling Capacity Heat Rejection Water Flow Rate Air Flow Rate Hot Water Temp. Cold Water Temp. Wet Bulb Temp. RT Kcal/hr /min m3/min
oC oC oC

TWO CELLS
YC300B YC350B YC400B YC450B YC500B

THREE CELLS
YC600B YC700B YC750B

FOUR CELLS
YC800B YC900B YC1000B

300
1170000

350
1365000

400
1560000

450
1750000

500
1950000

600
2340000

700
2730000

750
2925000

800
3120000

900
3510000

1000
3900000

Capacity

3900 1920

4550 2270

Overall Dimension

Width ( W ) Length ( L ) Height ( H )

mm mm mm

4000 4000

Casing / Basin Steel Structure Filler Distribution Tray Bolt & Nuts Louvers Fan

Material

Fan

Type Diameters Number of Blades Fan Speed ( Rpm ) Drive System Type Power Source Rated Output ( kW ) Quantity

7800 9100 9750 10400 3855 4580 4950 5140 37 32 27 4600 5200 6900 7800 9200 4300 4400 4300 4400 4300 3100 FRP Hot Dip Galvanized Steel PVC FRP Stainless Steel PVC FAN Blade : FRP , HUB = Aluminium alloy AXIAL FLOW 5200 2570 5850 2920 6500 3320
1800x2

11700

13000

5840

6640

10400 4400

1600 x 2

2000 x 2

1800x3

2000 x 3

1800x4

2000 x 4

FOUR
380 430 450 360 380 450 380 380 Fan Belts Drives TEFC IP55 3Phase / 415V / 50Hz / 400V / 60Hz
5.5 x 2 5.5 x 3 5.5 x 3 7.5 x 3

450

380

380

Motor

3.7 x 2

5.5 x 2

5.5 x 4

5.5 x 4

TWO 100 x 4 200 x 1 80 x 1 80 x 1 40 x 1 40 x 1 50x 1 50 x 1 125 x 4 250 x 1

Distribution System
Hot Water Inlet
Cold Water Outlet

Piping Dimension

Drain Pipe
Over Flow Pipe

Float Valve Make up Make Up Weight Noise Level


Evaporation Loss

Drift Loss

Dry Weight
Operating Weight

Measuring (W) Measuring (L)

mm mm mm mm mm mm (%) (%) Kg Kg dBA dBA

THREE By Open Gravity 125 x 6 200 x 2 80 x 2 80 x 2 40 x 2 40 x 2 0.83 0.01 3870 8340 62 54

FOUR 125 x 8 250 x 2

50 x 2 50 x 2

2300 4760 58 52

2320 4840 62 52

2580 5560 61 53

3120 6440 58 52

3200 6600 60 54

4720 9740 57 53

4800 9900 61 53

5160
11120

6240
12880

6400
13200

62 54

60 53

62 55

Page 2

SPECIFICATION FOR YCB H SERIES ( BUILD IN PIPING & COMPACT DESIGN TYPE )
ONE CELLS MODEL ITEM
Cooling Capacity RT Heat Rejection Kcal / h Water Flow Rate / min Capacity Air Flow Rate m3/min oC How Water Temperature oC Cold Water Temperature oC Wet-Bulb Temperature Width ( W ) mm Overall Length ( L ) mm Dimension Height ( H ) mm Casing Steel Structure Filler Distribution Tray Material Cold Water Basin Louver Fan Fan Stack TYPE Diameter mm Fan Number of Blades Fan Speed Rpm Fan Drive System Assembly TYPE Power Source Motor Rated Output kW Quantity Distribution System Hot Water Inlet Pipe mm Cold Water Outlet Pipe mm Piping Drain Pipe mm Dimension Overflow Pipe mm Float Valve mm Manual make up mm Evaporation Loss % Make up Drift Loss % Net Weight kg Weight Operating Weight kg Noise Measuring Direction ( W ) dBA Level Measuring Direction ( L ) dBA
NOTE : (1) (2) (3) (4) (5) Available for YCB150H YCB175H YCB200H YCB225H YCB250H YCB300H YCB325H YCB350H

150 585000 1950 1200

175 682500 2275 1275

200 780000 2600 1350

225 877500 2925 1580

250 975000 3250 1780

300 1170000 3900 1980

325 1267500 4225 2100

350 1365000 4550 2250

37 32 27 1650 2000 2300 2600 3650 4000 4300 4400 3700 FRP Steel ( Hot Dip Galvanized ) PVC FRP FRP PVC Blade : FRP , Hub : Aluminium Cast Alloy FRP AXIAL FLOW 1400 x 1 1600 x 1 1800 x 1 2000 x 1 4 400 480 530 580 620 BELT DRIVE Enclosed Fan Cooled , Outdoor IP55 Induction Motor 4 Poles 415V / 3Ph / 50Hz / 60Hz 3.7 x 1 5.5 x 1 7.5 x 1 11 x 1 1 Open Gravity Type 100 x 2 125 x 2 150 x 1 200 x 1 50 x 1 50 x 1 25 x 1 40 x 1 25 x 1 40 x 1 0.83% 0.01% 1100 1150 1200 1400 1600 1620 1780 1800 2480 2560 2650 3000 3300 3400 3750 3850 58 59 59 60 60.5 61.2 62 62.4 53 54 55 56 56.4 58 59 59.2

July 2006 YC S.S Stainless Steel Series YCB Build In Piping (Internal Piping) Series YC H Compact Design Type Above four cells and other configuration, please contact local agents Rated output motor and piping sizes varies depending on circulation water flow rate and temperature Nominal Cooling Capacity is base on 13 / min / RT ( 1RT = 3,900 Kcal / hr ) at 37oCHW.32oCCW and 27oCWB Data and specification are subject to be changed without prior notice

Page 1

SPECIFICATION FOR YCB H SERIES (BUILD IN PIPING & COMPACT DESIGN TYPE)
TWO CELLS
YCB300H 300 1170000 3900 2400 YCB400H 400 1560000 5200 2700 YCB450H 450 1755000 5850 3160 YCB600A(H) 600 2340000 7800 3960 YCB650H 650 2535000 8450 4200 37 32 27 3300 3650 4000 4000 4600 4300 5200 4400 5200 4400 4950 3650 6000 4000 6900 4300 7800 4400 7800 4400 YCB450H 450 1755000 5850 3600 YCB600H 600 2340000 7800 4050

THREE CELLS
YCB675H 675 2632500 8775 4740 YCB900A(H) 900 3510000 11700 5940 YCB975H 975 3802500 12675 6300

1400 x 2 400 x 2

1600 x 2 480 x 2

1800 x 2 530 x 2

4x2

5.5 x 2

5.5 x 2 2

100 x 4 150 x 2 50 x 2 50 x 2 25 x 2 25 x 2

2200 4960 58 53

2400 5300 59 55

2800 6000 60 56

3700 FRP Steel ( Hot Dip Galvanized ) PVC FRP FRP FRP Blade : FRP , Hub : Aluminium Cast Alloy FRP AXIAL FLOW 2000 x 2 2000 x 2 1400 x 3 1600 x 3 1800 x 3 4 580 x 2 580 x 2 400 x 3 480 x 3 530 x 3 BELT DRIVE Enclosed Fan Cooled , Outdoor IP55 Induction Motor 4 Poles 415V / 3Ph / 50Hz / 60Hz 7.5 x 2 7.5 x 2 4x3 5.5 x 3 5.5 x 3 3 Open Gravity Type 125 x 4 100 x 6 200 x 2 150 x 3 50 x 3 50 x 3 40 x 2 25 x 3 40 x 2 25 x 3 0.83% 0.01% 3240 3560 3300 3600 4200 6800 7500 7400 1950 7950 61.2 62 58 59 60 58 59 53 55 56

2000 x 3 580 x 3

2000 x 3 580 x 3

7.5 x 3

7.5 x 3

125 x 6 200 x 3

40 x 3 40 x 3

4860 10200 62 58

5340 11250 62 59

Page 2