COOLING TOWER
STANDARD MODEL ( YC SERIES ) BUILD IN PIPING TYPE ( YC B SERIES ) COMPACT DESIGN TYPE ( YC H SERIES )
Gank walk
The gank walk on top of the water basin for cleaning ,lubrication and maintenances.
ONE CELLS
YC100B YC125B YC150B YC175B YC200B YC225B YC250B YC275B YC300B
Capacity
Hot Water Temp. Cold Water Temp. Wet Bulb Temp. Width ( W ) Length ( L ) Height ( H )
Overall Dimension
mm mm mm
1650 3650
Material
Distribution Tray Bolt & Nuts Louvers Fan Type Diameters Number of Blades Fan Speed ( Rpm ) Drive System Type Power Source Rated Output ( kW ) Drive System
Fan
Motor
2.2 x 1
Distribution System
Hot Water Inlet Cold Water Outlet Drain Pipe Over Flow Pipe Float Valve Make up
Piping Dimension
Evaporation Loss Drift Loss Dry Weight Operating Weight Measuring ( W ) Measuring ( L )
mm mm mm mm mm mm (%) (%) Kg Kg
dBA dBA
(1) (2) (3) (4) (5)
80 x 2 150 x 1
1050 2210 52 46
Available for
1080 2270 57 51
200 225 250 275 300 780000 877500 975000 1072500 1170000 2600 2925 3250 3575 3900 1285 1460 1660 1540 1980 37 32 27 2000 2300 2600 4000 4300 4400 3250 FRP Hot Dip Galvanized Steel PVC FRP Hot Dip Galvanized Steel PVC Fan Blade : FRP , HUB = Aluminium Alloy AXIAL FLOW 1600 x 1 1800 x 1 2000 x 1 FOUR 380 430 450 360 380 430 Fan Belts Drives TEFC IP55 3Phase / 415V / 50Hz / 400V / 60Hz 3.7 x 1 5.5 x 1 7.5 x 1 One By Open Gravity 100 x 2 125 x 2 150 x 1 200 x 1 50 x 1 50 x 1 25 x 1 40 x 1 25 x 1 40 x 1 0.83 0.01 1150 1160 1290 1560 1600 1610 1620 2380 2420 2780 3220 3300 3350 3400 55 59 57 55 57 58 59 49 53 52 52 53 54 55
July 2006
NOTE :
YC S.S Stainless Steel Type YCB H Build In Piping & Compact Design Type YC H Compact Design Type Above four cells and other configuration, please contact local agents Rated output motor and piping sizes varies depending on circulation water flow rate and temperature Nominal Cooling Capacity is base on 13 / min / RT ( 1RT = 3,900 Kcal / hr ) at 37oCHW.32oCCW and 27oCWB Data and specification are subject to be changed without prior notice
Page 1
TWO CELLS
YC300B YC350B YC400B YC450B YC500B
THREE CELLS
YC600B YC700B YC750B
FOUR CELLS
YC800B YC900B YC1000B
300
1170000
350
1365000
400
1560000
450
1750000
500
1950000
600
2340000
700
2730000
750
2925000
800
3120000
900
3510000
1000
3900000
Capacity
3900 1920
4550 2270
Overall Dimension
mm mm mm
4000 4000
Casing / Basin Steel Structure Filler Distribution Tray Bolt & Nuts Louvers Fan
Material
Fan
Type Diameters Number of Blades Fan Speed ( Rpm ) Drive System Type Power Source Rated Output ( kW ) Quantity
7800 9100 9750 10400 3855 4580 4950 5140 37 32 27 4600 5200 6900 7800 9200 4300 4400 4300 4400 4300 3100 FRP Hot Dip Galvanized Steel PVC FRP Stainless Steel PVC FAN Blade : FRP , HUB = Aluminium alloy AXIAL FLOW 5200 2570 5850 2920 6500 3320
1800x2
11700
13000
5840
6640
10400 4400
1600 x 2
2000 x 2
1800x3
2000 x 3
1800x4
2000 x 4
FOUR
380 430 450 360 380 450 380 380 Fan Belts Drives TEFC IP55 3Phase / 415V / 50Hz / 400V / 60Hz
5.5 x 2 5.5 x 3 5.5 x 3 7.5 x 3
450
380
380
Motor
3.7 x 2
5.5 x 2
5.5 x 4
5.5 x 4
Distribution System
Hot Water Inlet
Cold Water Outlet
Piping Dimension
Drain Pipe
Over Flow Pipe
Drift Loss
Dry Weight
Operating Weight
50 x 2 50 x 2
2300 4760 58 52
2320 4840 62 52
2580 5560 61 53
3120 6440 58 52
3200 6600 60 54
4720 9740 57 53
4800 9900 61 53
5160
11120
6240
12880
6400
13200
62 54
60 53
62 55
Page 2
SPECIFICATION FOR YCB H SERIES ( BUILD IN PIPING & COMPACT DESIGN TYPE )
ONE CELLS MODEL ITEM
Cooling Capacity RT Heat Rejection Kcal / h Water Flow Rate / min Capacity Air Flow Rate m3/min oC How Water Temperature oC Cold Water Temperature oC Wet-Bulb Temperature Width ( W ) mm Overall Length ( L ) mm Dimension Height ( H ) mm Casing Steel Structure Filler Distribution Tray Material Cold Water Basin Louver Fan Fan Stack TYPE Diameter mm Fan Number of Blades Fan Speed Rpm Fan Drive System Assembly TYPE Power Source Motor Rated Output kW Quantity Distribution System Hot Water Inlet Pipe mm Cold Water Outlet Pipe mm Piping Drain Pipe mm Dimension Overflow Pipe mm Float Valve mm Manual make up mm Evaporation Loss % Make up Drift Loss % Net Weight kg Weight Operating Weight kg Noise Measuring Direction ( W ) dBA Level Measuring Direction ( L ) dBA
NOTE : (1) (2) (3) (4) (5) Available for YCB150H YCB175H YCB200H YCB225H YCB250H YCB300H YCB325H YCB350H
37 32 27 1650 2000 2300 2600 3650 4000 4300 4400 3700 FRP Steel ( Hot Dip Galvanized ) PVC FRP FRP PVC Blade : FRP , Hub : Aluminium Cast Alloy FRP AXIAL FLOW 1400 x 1 1600 x 1 1800 x 1 2000 x 1 4 400 480 530 580 620 BELT DRIVE Enclosed Fan Cooled , Outdoor IP55 Induction Motor 4 Poles 415V / 3Ph / 50Hz / 60Hz 3.7 x 1 5.5 x 1 7.5 x 1 11 x 1 1 Open Gravity Type 100 x 2 125 x 2 150 x 1 200 x 1 50 x 1 50 x 1 25 x 1 40 x 1 25 x 1 40 x 1 0.83% 0.01% 1100 1150 1200 1400 1600 1620 1780 1800 2480 2560 2650 3000 3300 3400 3750 3850 58 59 59 60 60.5 61.2 62 62.4 53 54 55 56 56.4 58 59 59.2
July 2006 YC S.S Stainless Steel Series YCB Build In Piping (Internal Piping) Series YC H Compact Design Type Above four cells and other configuration, please contact local agents Rated output motor and piping sizes varies depending on circulation water flow rate and temperature Nominal Cooling Capacity is base on 13 / min / RT ( 1RT = 3,900 Kcal / hr ) at 37oCHW.32oCCW and 27oCWB Data and specification are subject to be changed without prior notice
Page 1
SPECIFICATION FOR YCB H SERIES (BUILD IN PIPING & COMPACT DESIGN TYPE)
TWO CELLS
YCB300H 300 1170000 3900 2400 YCB400H 400 1560000 5200 2700 YCB450H 450 1755000 5850 3160 YCB600A(H) 600 2340000 7800 3960 YCB650H 650 2535000 8450 4200 37 32 27 3300 3650 4000 4000 4600 4300 5200 4400 5200 4400 4950 3650 6000 4000 6900 4300 7800 4400 7800 4400 YCB450H 450 1755000 5850 3600 YCB600H 600 2340000 7800 4050
THREE CELLS
YCB675H 675 2632500 8775 4740 YCB900A(H) 900 3510000 11700 5940 YCB975H 975 3802500 12675 6300
1400 x 2 400 x 2
1600 x 2 480 x 2
1800 x 2 530 x 2
4x2
5.5 x 2
5.5 x 2 2
100 x 4 150 x 2 50 x 2 50 x 2 25 x 2 25 x 2
2200 4960 58 53
2400 5300 59 55
2800 6000 60 56
3700 FRP Steel ( Hot Dip Galvanized ) PVC FRP FRP FRP Blade : FRP , Hub : Aluminium Cast Alloy FRP AXIAL FLOW 2000 x 2 2000 x 2 1400 x 3 1600 x 3 1800 x 3 4 580 x 2 580 x 2 400 x 3 480 x 3 530 x 3 BELT DRIVE Enclosed Fan Cooled , Outdoor IP55 Induction Motor 4 Poles 415V / 3Ph / 50Hz / 60Hz 7.5 x 2 7.5 x 2 4x3 5.5 x 3 5.5 x 3 3 Open Gravity Type 125 x 4 100 x 6 200 x 2 150 x 3 50 x 3 50 x 3 40 x 2 25 x 3 40 x 2 25 x 3 0.83% 0.01% 3240 3560 3300 3600 4200 6800 7500 7400 1950 7950 61.2 62 58 59 60 58 59 53 55 56
2000 x 3 580 x 3
2000 x 3 580 x 3
7.5 x 3
7.5 x 3
125 x 6 200 x 3
40 x 3 40 x 3
4860 10200 62 58
5340 11250 62 59