You are on page 1of 4

PORTABLE MEASURING INSTRUMENTS

,e_t_L2I_qi
15
15-37
Recorders Darwin
Darwin DA100 Data Acquisition Unit


Data Acquisition Unit
DA100
The DA100 data acquisition unit provides an expandable and highly flexible data
acquisition environment when a personal computer is used as the human
interface.
High configuration flexibility
The instrument comes in two versions, a stand-alone model which can acquire
data from up to 40 channels, and an expandable model which can be freely
expanded by the user to accommodate a maximum of 300 channels.
PC-friendly
By using the data logging software provided, you can configure a personal
computer-based data acquisition environment with the ease of plug and play.
High speed and highly accurate measurement
The instrument has a scanning speed of 300 channels/500 ms, permitting
high-speed and highly accurate measurement.
A wealth of input and output modules A wide variety of input modules,
including voltage, temperature, (TCs and RTDs), contact, strain, pulse, and
power monitoring, mA (DC current) modules, and also output modules, such
as communication and alarm output modules, are available.
Excellent economy
Reduced wiring with remote measurement over a distance of up to 500 m, and
space savings from making a smaller unit.
High reliability and environmental toughness
The instrument has high environmental toughness and reliability, enabling it
to be used under various severe environmental conditions encountered in
the field.

DA100 Specifications
Number of input points: expandable and changeable on a module basis.
Stand-alone model: 10 to 40 channels
Expandable model: 10 to 300 channels
Types of inputs:
DC voltage (20 mV to 50 V), TC (types R, S, B, K, E, J, T, N, W, L, and U),
RTD, mA, pulse, power
monitoring, strain, etc.
Types of communication: via GP-IB, RS-232C, or RS-422A interface
Remote measurement (expandable model)
Up to total 500 m using a dedicated cable
Up to 6 subunits can be connected.
Measuring cycle: 0.5 to 60 s
Integration time: 50 ms, 60 ms, or 100 ms
Other: alarm output
Option: computation function
PC software: Beagle for DARWIN; InTouch for DARWIN
External dimensions:
Stand-alone model:
approx. 422 (W) x 176 (H) x 100 (D) mm
Expandable model:
approx. 336 (W) x 165 (H) x 100 (D) mm
Subunit: approx. 422 (W) x 176 (H) x 100 (I)) mm
Weight: approx. 4 kg each (with modules mounted)
Recorders Darwin
Darwin DR230 Hybrid Recorder

Hybrid Recorder
DR230
The DR230 Hybrid Recorder has high functional expandability and measurement
configuration flexibility, enabling it to be used as a research and development tool
in various industries for a wide range of applications, from small-scale data
logging to multipoint data acquisition.
High configuration flexibility
This recorder can be flexibly configured and expanded to cope with a variety
of applications, from small-scale data logging to multipoint data acquisition.
The recorder comes in two models: an expandable model with which the user
can expand the modules from 10 to 300 channels and a stand-alone model for
simple configurations of up to 30 channels.
Excellent economy
Reduced wiring with remote measurement over a distance of up to 500 m, and
space savings from making a smaller unit.
High-speed and highly accurate measurement
The instrument has a scanning speed of 300 channels/500 ms, permitting
high-speed and highly accurate measurement.
PC-friendly
A personal computer-based data recording environment can be configured
with the ease of plug-and-play. A floppy disk drive and an IC memory card can
be mounted in the instrument.
A wealth of input and output modules
A wide variety of input modules, including voltage, temperature, (TCs and
RTDs), contact, strain, pulse, and power monitoring, mA (DC current)
modules, and also output modules, such as communication and alarm output
modules, are available.
High functionality
Ten-color clear recording, complete computation functions, supply of power to
input modules, etc.

DR230 Specifications
Number of input points
Stand-alone model: Specify 10, 20, or 30 channels. Expandable model: 10 to
300 channels (expandable and changeable)
Types of inputs: DC voltage, TC, RTD, mA, pulse, power monitoring, strain
(partial expansion only)
Types of communication: via GP-IB, RS-232C, or RS-422A/485 interface
Others: alarm output, remote function
Remote measurement (expandable model):
Up to a total of 500 m using a dedicated cable
Up to 6 subunits can be connected.
Measuring cycle: 0.5 to 60 s
0.5 s (expandable model) to 60 s
(2 s or more with stand-alone model)
Recording cycle: shortest 2 s
Recording functions: ten-color dot recording; effective recording width of 250
mm
Display: VFD 5 by 7 dot matrix, 3-digit display
Memory: 3.5-inch floppy disk drive with 512 KB SRAM
Option: computation function, report computation function
PC software: Beagle for DARWIN, InTouch for DARWIN
External dimensions
Stand-alone model:
approx. 438 (W) x 291 (H) x 336 (D) mm
Expandable model:
approx. 438 (W) x 291 (H) x 301 (D) mm
Subunit: approx. 422 (W) x 176 (H) x 100 (D) mm
Weight: approx. 13 kg (with modules fully mounted)
PANEL RECORDERS
PORTABLE MEASURING INSTRUMENTS
,e_t_L2I_qi
15
15-38
Recorders Darwin
Darwin DR240 Hybrid Recorder

Hybrid Recorder
DR240
The DR240 Hybrid Recorder is a panel-mounted industrial recorder containing a
highly reliable, high withstanding voltage solid-state relay developed by Yokogawa.
It can withstand harsh environmental conditions and is ideal for process monitoring.
High reliability and environmental toughness
The instrument has high environmental toughness and reliability, enabling it to
be used under the various harsh environmental conditions encountered in the
field. The input scanner section contains a high withstanding voltage surface-
mounted solid-state relay developed by Yokogawa, allowing a high degree of
compactness and high reliability.
High configuration flexibility
The instrument can be flexibly configured and expanded in the field, permitting
measurement of data from 10 up to a maximum of 300 channels. A stand-alone
model for simple configurations up to 30 channels is also available.
Excellent economy
Reduced wiring with remote measurement over a distance of up to 500 m, and
space savings from making a smaller unit.
PC-friendly
A personal computer-based data recording environment can be configured with
the ease of plug-and-play. A floppy disk drive and an IC memory card can be
mounted in the instrument.
A wealth of input and output modules
A wide variety of input modules, including voltage, temperature, (TCs and
RTDs), contact, strain, pulse, and power monitoring, mA (DC current) modules,
and also output modules, such as communication and alarm output modules,
are available.
High functionality
Ten-color clear recording, complete computation/report functions, supply of
power to input modules, etc.

DR240 Specifications
Number of input points
Stand-alone model: Specify 10, 20, or 30 channels. Expandable model: 10 to
300 channels (expandable and changeable)
Types of inputs: DC voltage, TC, RTD, mA, pulse, power monitoring, strain
(partial expansion only)
Types of communication: via GP-IB, RS-232C, or RS-422A/485 interface
Others: alarm output, remote function
Remote measurement (expandable model):
Up to a total of 500 m using a dedicated cable
Up to 6 subunits can be connected.
Measuring cycle: 0.5 to 60 s
0.5 s (expandable model) to 60 s
(2 s or more with stand-alone model)
Recording cycle: shortest 2 s
Recording functions: ten-color dot recording; effective recording width of 250
mm
Display: VFD 5 by 7 dot matrix, 3-digit display
Memory: 3.5-inch floppy disk drive with 512 KB SRAM
Option: computation function, report computation function
PC software: Beagle for DARWIN, InTouch for DARWIN
External dimensions
Stand-alone model:
approx. 444 (W) x 288 (H) x 343 (D) mm
Expandable model:
approx. 444 (W) x 288 (H) x 308 (D) mm
Subunit: approx. 422 (W) x 176 (H) x 100 (D) mm
Weight: approx. 16 kg (with modules fully mounted)
Darwin DR130 Hybrid Recorder

Portable Hybrid Recorder
DR130
This recorder packs both high functionality and high reliability into a compact body
weighing 10 kg or less and, thus, is excellent in mobility and functionality. Harmony
with a personal computer has also been improved by incorporating a floppy disk
drive function.
Compact and lightweight, portable
Made one size smaller than conventional models, it has become lighter, and
mobility has increased.
Data saving onto a floppy disk
Data setting and measured data can be saved on a floppy disk. Measured data
are saved via the attached 512 KB SRAM to improve reliability. The data can be
converted to Excel or Lotus 1-2-3 using the attached data conversion software.
PC-friendly
A wealth of PC software enables the PC-based data acquisition environment to
be flexibly configured.
Universal Input
The input section where each channel is isolated incorporates a signal
conditioner function which universally measures various inputs of voltages,
thermocouples, RTDs, contacts, etc.

DR130 Specifications
Number of input points: 10 or 20 channels specified
Types of input: DC voltage, thermocouples, and RTDs
Types of communication: via GP-IB or RS-232C interface
Measuring cycle: 2 to 60 s
Recording cycle: shortest - 2 s
Recording function: ten-color dot recording, effective recording width 150 mm
Display: VFD 5 by 7 dot matrix, 3-digit display
Memory: 3.5-inch floppy disk drive with 512 KB SRAN
Option: computation, alarm output, remote, power monitoring, and report
computation functions
PC software: Beagle for DARWIN, InTouch for DARWIN
External dimensions: approx. 338 (W) x 221 (H) x 335 (D) mm
Weight: approx. 9.3 kg
PORTABLE MEASURING INSTRUMENTS
,e_t_L2I_qi
15
15-39
Darwin PC-based Data Logging Software
for Laboratory Use


PC-based Data Logging Software for
Laboratory Market
"Beagle for DARWIN" is PC-based data logging software mainly for laboratory use.
This enables the PC-based data logging environment using DARWIN to be easily
configured and strongly supports settings for the measurement environment, data
acquisition and monitoring, data analysis, data conversion, etc.
Standard software
This executes DA100 setting, easy data logging, data monitoring and data
conversion. One copy of the software is included with each DA100 as standard.
Basic software (sold separately)
This supports DR recorder setting, operation control for start/stop of recording
and printing start, easy data logging, data monitoring, and data conversion.
Data conversion software (standard with the floppy disk function)
Data stored on the floppy disk of a DR recorder are converted to Excel, Lotus 1-
2-3, or ASCII format.
Enhanced data logging software (sold separately)
Monitor functions are completed including alarm monitoring and historical trend
functions in addition to trend display, digital value display, level meter display,
etc. As 32 channels are displayed in one window and more than one window is
displayed at a time, simultaneous monitoring of multi-channels and free screen
configuration can be implemented. Measured data zooming and scrolling are
also available. A required part can be globally converted to Excel, Lotus 1-2-3, or
ASCII format with smooth cursor operation.

Enhanced Data Logging Software
Specifications
Data logging:
Data for up to 300 channels are logged in the fastest 0.5-s cycle and stored on
the hard disk of a personal computer.
Data Monitoring:
Measured data for any 32 channels/window are displayed. Multiple windows can
be simultaneously displayed.
Types of display:
Trend, digital, level meter, and alarm status monitoring
Historical trend:
During data logging, expansion of display time-base, referencing past data with
scrolling, measured value readouts with the cursor, etc. can be done.
Data redisplay:
Redisplay of data stored on the hard disk Measured data readout with the cursor,
interval arithmetic (max./min./p-p/average), zoom function
Data conversion:
Conversion to ASCII, Lotus 1-2-3, Excel
Data printing: trend printing of displayed waveform available
OS: MS-DOS, Windows 3.1
Communication: CP-lB or RS-232C interface
InTouch Darwin PC-based
Data Logging Software


PC-based Data Logging Software for Process
Monitor
InTouch for DARWIN
Data logging software dedicated to DARWIN co-developed with WonderWare
Company, the largest SCADA vendor in the U.S. Many process monitor needs are
considered, for example, automatic group preparation using tag numbers,
overview screen, instrument faceplates, and alarm monitoring screen.
Easy engineering
Easy engineering is realized by eliminating technical Computer jargon as
much as possible. A system is automatically operated by setting
communication conditions and tag numbers.
A wealth of display functions necessary for process monitoring
Various monitoring screens, such as the overview screen on which the
operating conditions over entire processes can be monitored at a glance, the
instrument faceplate screen on which specific group input instruments can be
monitored with indicators and meter displays, the alarm monitoring screen on
which alarms currently occurring are listed, historical monitor, etc.
Low cost and rapid configuration of total system
A PC-based multipoint process monitoring environment can flexibly
constructed using DARWIN series instruments for the hardware.

Specifications
Data logging:
Data for up to 300 channels are logged in the fastest 0.5-s cycle and stored on
the hard disk of a personal computer.
Number of input points:
Maximum of 40, 120, or 300 channels (selected depending on model)
Monitoring screens
Overview, channel overview, instrument faceplate (vertical indicators or
meters), individual detailed screens and real-time trend, historical trend, and
alarm monitoring screens
Other displays:
Current time, remaining disk area, and communication status are displayed.
File input/output:
Saving to a file and read-out of historical data, alarm history and conversion
and storing of historical data to CSV files
User management function:
Usable functions can be limited by entering the user name and passwords.
Business form output (optional):
Daily and monthly reports are output to a printer for printing (requires Excel
version 7.0).
OS: Windows 3.1, Windows 95
PORTABLE MEASURING INSTRUMENTS
,e_t_L2I_qi
15
15-40
Industrial Recorders

Industrial Recorders
R1000/R1800
High reliability by employing fully contactless
technology
Compact and lightweight, 220 mm deep
Variety of models
1-, 2-, 3-, or 4-pen writing/6 dot-printing
model (R1000)
1-, 2-, 3 or 4-pen writing/6-, 12-, 16 or 24
dot printing model (R1000)
Crisp display: Large dot matrix display
Simple interactive operation

Industrial Recorders
RS1000/RS1800
Simple operation
Recording available immediately upon power
on
Provided with analog scale enabling re-
cording position to be known at a glance.
High reliability
Widely selectable from a total of 13 models
Digital display function (optional)
VR200 Specifications
Number of input channels: 4 or 6
Types of input:
DC voltage 20 mV to 20 V
Thermocouple types R, S, B, K, E, J, T, N, W, L, and U
RTD Pt100 or JPt100
Operation record
DC current (with external shunt resistor)
* arbitrary mixed input
Display: 5.5 TFT color LCD
External storing medium: 3.5-inch floppy disk (2 HD)
Memory capacity: about one-month's worth for 4/6 channels at a sampling cycle
of 60 s (many sampling cycles can be set.)
Types of alarm: high and/or low and high and/or low for difference, high and/or
low for rate-of-change
Option: alarm output, RS-422A communication, remote control, fail/memory end
output, etc.
External dimensions: 144 (W) x 144 (H) x 280 (D) mm
Weight: approx. 2.9 kg for 4-channel model
approx. 2.8 kg for 6-channel model
Industrial Recorder

Turbine Vibration Monitoring
Recorder for Power Plants
R12000
Crisp recording in 12 colors with effective
recording width of 250 mm
High reliability by employing fully non-contact
technology
Cartridge pen requiring no ink replenishing
Provided with internal lighting and transparent
scale plate as standard
Easy, direct data reading with various re-
cording and print functions
Universal input regardless of sensors
User-need-intensive, simple, interactive operation.

View Recorders
View Recorder
VR100
Data stored on a floppy disk can be regener-
ated or processed at a PC.
High precision recording using digital data
Chart paper that requires no ink reduces run-
ning costs.
Crisp indication using high resolution TFT
liquid crystal display
Data can be easily stored simply by inserting a
floppy disk.
Four-channel model and six-channel model
cover diversified applications.
VR100 Specification
Number of input channels: 4 or 6
Types of input:
DC voltage 20 mV to 20 V
Thermocouple types R, S, B, K, E, J, T, N, W, L, and U
RTD Pt100 or JPt100 Operation record
DC current (with external shunt resistor) * arbitrary mixed input
Display: 5.5 TFT color LCD
External storing medium: 3.5-inch floppy disk (AHD)
Memory capacity: about one month's worth for 4/6 channels at a sampling cycle
of 60 s (many sampling cycles can be set.)
Types of alarm: high and/or low and high and/or low for difference, high and/or
low for rate-of-change
Option: alarm output, RS-422A communication, remote control, fail/memory end
output, etc.
External dimensions:
144 (W) x 144 (H) x 280 (D) mm for panel-mounting model
144 (W) x 191.5 (H) x 326 (D) mm for desktop model
Weight: 2.7 to 3.2 kg

Wide View Recorder
VR200
Excellent screen visibility with wide angle of visibility
Monitoring support with a variety of display functions
Data stored on a floppy disk can be regenerated or processed at a PC.
Chart paper that requires no ink reduces running costs.
Data can be easily stored simply by inserting a floppy disk.
Four-channel model and six-channel model cover diversified applications.
VR Application Software Package


VR Application Software Package
VP100
A package of DOS data conversion
software and Windows 3.1 data conversion/
viewer software
Measured data stored on a floppy disk
using a VR recorder can be converted to
several formats.
Waveform display and printout of measured
data are available.

VP100 Specifications
File conversion software system
environmental conditions
PC mainframe:
PC-9801VX and PC9801 later than PC-9801VX or PC9821 from NEC
Corporation
IBM PC/AT from IBM Corporation or compatible machines
Memory: 640 KB or mor (free space of 400 KB or more)
OS: MS DOS, MS DOS/V ver. 5.0 or later
Disk: 3.5-inch floppy disk drive (1.44 MB format)
File conversion/data viewer software system environmental conditions
PC mainframe: personal computers in which Japanese version of MS Windows
3.1 is running
CPU: 80386 SX or better
Memory: 8 MB or more
OS: Japanese version of MS Windows 3.1
Disk: 3.5-inch floppy disk drive (1.44 MB format)
hard disk (free space of 2 MB or more)
CRT: display supports Japanese version of MS Windows 3.1
(display which can display in 16 colors or more recommended)
Printer: Printer and printer driver that support
Japanese version of MS Windows 3.1

VR Enhanced Data Viewer Software

VR Enhanced Data Viewer Software
VA100
Data viewer software supporting both
Windows 3.1 and Windows 95
Waveform regeneration display in chart
images possible
Waveform data readout using cursor
available
Measured data can be converted to Excel
or Lotus format.
A100 Specifications
System environmental conditions
PC mainframe: personal computers in which Japanese version of MS Windows
3.1 or Windows 95 is operable
CPU: 80486 D X 2 or better (Pentium 90 or better recommended)
Memory: 16 MB or more
OS: Japanese version of MS Windows 3.1 or Windows 95
Disk: 3.5-inch floppy disk drive (1.44 MB format)
hard disk (free space of 2 MB or more)
CRT: Display which can display in 256 colors and
supports Japanese version of MS Windows 3.1 or Windows 95
(display which can display in 64,000 colors or more recommended)
Printer: Printer and printer driver that support Japanese version of MS
Windows 3.1 or Windows 95

You might also like