Lab #8
"AIR-CONDITIONING"
Apparatus:
Air-conditioning unit consists of two parts: 1. Air system : a) fan and speed control. b) Electrical heater. c) Boiler; to add moisture. d) Air flow measurement. 2. Refrigerant system : a) compressor. b) Condenser. c) Refrigerant evaporator.
Procedure:
After operating the fan to have air stream;
Qa = sum of the rate of heat transfer at the heating or cooling surface and the external heat transfer to or from the surrounding atmosphere. Wa = rate of work done or by the system. ma = mass flow rate of air flowing in the duct. hd = enthalpy of air at section D. hg = enthalpy of air at section G. Vg = mean velocity of air at section D. Vd = mean velocity of air at section G. Since Wa = 0 and Vg = Vd the equation reduces to : Qa = ma(hg- hd) From the continuity equation : ma = [Ad*Vd] / Vd =Vod / Vd Where: Ad = cross sectional area of the duct =0.0645 m Vd = spesific volume of air (obtained from psychometric chart) Vod = volume flow rate.
In section 3:Twet= 29,Tdry = 43 ; then from the psychometric chart vg= 0.917m/kg hg=95 KJ/Kg In section 2 : Twet =32, Tdry =48 ; also the psychometric chart: vd=0.94 m3/kg hd=115 KJ/Kg Using : ma = Q/vd = 285/.94 = 303.2 kg/sec Qa =303.2[95-115] = -6064W/Sec hd=enthalpy of air at section 2. hg= enthalpy of air at section 3. Ad=cross sectional area of the duct =0.0645 m
Vd = Q/Ad =285/0.0645= 4411.76 m/sec The rest of the calculations "results" : Q (m/h) vd(m/kg) hg (KJ/kg) hd (KJ/kg) ma (kg/h) 285 370 440 0.94 0.931 0.925 95 95 94.5 115 109 105 303.2 437.2 517.62 Q(w/s) -6064 -6120.30 -5435.02
Section 2 Twet ( C) 30 31 30 31 31 31
o
In section 3 : as above : hg=65,vg=0.86 In section 2 : hd=95,vd=0.896 ma=285/0.896=318.1kg/h Q=318.1[65-95]= -9542.4W/Sec The rest of the calculations "results" :
Q (m/h) vd(m/kg) hg (KJ/kg) hd (KJ/kg) ma (kg/h) 285 370 440 0.896 0.993 0.888 65 62 68 95 90 85 318.1 409.40 529.30