Professional Documents
Culture Documents
Company Address: 1321 77th Street, East Palmetto, Florida, 34221, USA Welders Name: David Turk Identification No: 5240 Type of welder: Welder Qualification Date: 5/4/13 Rev. 0
Welding Performance Qualification Record WPQR No. DT-5240 QC-11-SMAW-1 Welding Procedure Specification WPS No. QC-11-SMAW-1 BASE METALS USED Material Specification, Type or Grade: ASTM A 36 (T<= 3/4 in. [20 mm]) Welded to Material Specification, Type or Grade: ASTM A 36 (T<= 3/4 in. [20 mm]) Variables Welding Process Process Type Electrode (Single or Multiple) Current Type/Polarity Backing (Yes or No) Testing Position(s) and Qualified Welding Position(s): Groove Fillet Vertical Progression Plug or Slot Welds Base Metals Thickness in (mm): Groove Fillet Plug or Slot Welds Base Metals Diameter in (mm) (Pipe or Tube): Groove Fillet Filler Metal Specification (SFA) Filler Metal Classification (AWS Classified) Filler Metal F-Number Gas/Flux (SAW) Other Variable (coating type/thickness, etc.)
Plate Plate Actual Values Used SMAW Manual Single DCEP Yes n/a 3F Uphill
Pipe Pipe
Sheet Sheet
n/a 1/2 in. (12 mm), Fig. 5.21 n/a n/a Plate tested A5.1 E7018 4 n/a n/a Results
n/a Unlimited n/a n/a n/a Any AWS A5 Class Approved 4 (low-hydrogen only) n/a n/a
Visual Inspection of Completed Weld (D1.5, 6.26.1): Acceptable YES NO Guided Bend Test Type and Results (D1.5, 5.27.3): n/a Result and Comments: Fillet-Weld Test Results (D1.5, 5.27.4 and 5.27.6): Appearance: Acceptable Fillet Size in (mm): .385 Fracture Test Root Penetration: Acceptable Macroetch: Acceptable (Describe the location, nature, and size of any crack or tearing of the specimen.) Result and Comments: Resource id #9 Inspected by: Jonathan B. Stringer Test Number: G-0239-S Organization: Renegade Testing & Inspection Inc. Date: 5-4-2013 Alternative * Radiographic Test Results (D1.5, 5.26.1) : * In lieu of Guided Bend Test, except for GMAW-S Film Identification No. n/a Film interpreted by: n/a Organization: n/a Other information: n/a Results Remarks Film Identification No. Results Remarks
We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.5M/D1.5:2010, Bridge Welding Code. Manufacturer/ Contractor Authorized By: Welding Engineer Name: Jonathan B. Stringer Title: CWI - 10081211 Signature: Date: 5-4-13 Name: Title: Signature: Date: