RBS6201 3RD CARRIER IMPLEMENTATION

REQUIREMENTS:
1 2 3 4 All materials needed should be available (SUBRACK, CABLES, ADDITIONAL DUW) see Layout for Cable reference Script for 3rd Carrier Configuration Proper Tools (Laptop with Cables to Connect to RBS6201, 2nd Subrack Installation) Softwares (Element Manager, PUTTY or HyperTerminal, Bison)

PROCEDURE
1 2 3 4 5 6 Open MDT call Integration to perform HC and Backup CV for Site Call Integration to perform HC and Backup CV for Site Install 2nd SUBRACK Insert 2nd DUW into the expansion (still powered down) Switch "ON" and Format Secondary DUW (NO CABLES CONNECTED) . After Format Switch"OFF" again Do the cabling as shown in the Layout Run the modify script to add the 2nd DUW to the RBS (switch on 2nd DUW if you see waiting for start up of board in the Modify-Wizzard Note:

If script loading is taking too much time (more than 10 mins) you need to switch "OFF" an and observe if the script loading will continue

7 8 9 10 11 12 13

If already finished with script loading, check the status of the 2nd DUW with EMAS (needs to be enabled) Check the status of the 2nd DUW with MOSHELL using cab With the command cab you see that the 2nd DUW is in synch status. (Need to restart cabinet if 2nd DUW is no Wait until the synch status of the 2nd DUW is StandbyReady Verify with Integration Team for the Status of 2nd DUW Create a CV (Ex. After_DUW_sync ) Start upgrading to R3M02 Export and Delete the Configuration. Load the Cabinet and Site with 3rd Carrier Configuration

MPLEMENTATION

Layout for Cable reference

rmat Switch"OFF" again

you need to switch "OFF" and the switch "ON" again the Secondary DUW

needs to be enabled)

tart cabinet if 2nd DUW is not showing on moshell)

INTEGRATION TEAM

RPM 777 263 / 00650 - R1B SIGNAL CABLE (IDL to IDL Connection from Primary to Secondary DUW)

IMPORTANT
IDL Cable labeled with "PRIMARY" should be connected to the primary DUW and "SECONDARY" to secondary DUW and do not be mistaken to interchange, otherwise primary DUW will be corrupted
Connected to PDU

RPM 777 193 / 01000 R1C DC POWER CABLE WCDMA Need Additional 1 pc (Power Cable for Secondary DUW)

RPM 777 279 / 00650 R1B SIGNAL CABLE ( F to F Connection from Primary to Secondary DUW)

RPM 777 277 / 00900 R3A SIGNAL CABLE (approximate length 1m) Existing from Cabinet Delivery (3pcs Only) (Connection from RUW to Primary DUW)

CABLES NEEDED FOR 3rd CARRIER RPM 777 277 / 00900 RPM 777 263 / 00650 RPM 777 279 / 00650 R1B RPM 777 193 / 01000 R1C R3A

RPM 777 277 / 00900 R3A SIGNAL CABLE (approximate length 1m) Need additional 3 pcs for 3rd Carrier (Connection from RUW to Secondary DUW)

very (3pcs Only) Primary DUW)

NEEDED FOR 3rd CARRIER R3A - 3pcs - 1pc - 1pc - 1pc

7 277 / 00900

7 263 / 00650 - R1B

7 279 / 00650 R1B

7 193 / 01000 R1C

RPM 777 263 / 00650 - R1B SIGNAL CABLE (IDL to IDL Connection from Primary to Secondary DUW)

RPM 777 279 / 00650 R1B SIGNAL CABLE ( F to F Connection from Primary to Secondary DUW)

RPM 777 277 / 00900 SIGNAL CABLE

R3A

RPM 777 277 / 00900 R3A SIGNAL CABLE (approximate length 1m) Need additional 3 pcs for 3rd Carrier (Connection from RUW to Secondary DUW)

RPM 777 193 / 01000 R1C DC POWER CABLE WCDMA Need additional 1 pc (Power Cable for Secondary DUW)

HOW TO FORMAT DUW (Connect to RBS6201 LMT A port using Serial Connection)

username: rbs password:rbs Welcome to OSE Shell ose5.3.

$ reload -OSE Delta PowerPC/BL250206 Welcome to OSE Shell ose5.3. $ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT Plug-in Unit Product Name: DUW3001 Plug-in Unit Product No: KDU127161/3 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20110120 Plug-in Unit Product Serial: CB4G222342 Ethernet MAC_address 0: 0xC835B842FAA2 RAM size: 1024 Mbytes Stop due to remain in basic/backup set

formathd /d
All data on volume will be destroyed. Continue? y/n (n):y Formatting Hard Disk...

$ reload -OSE Delta PowerPC/BL250206 Welcome to OSE Shell ose5.3. $ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT Plug-in Unit Product Name: DUW3001 Plug-in Unit Product No: KDU127161/3 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20110120 Plug-in Unit Product Serial: CB4G222342 Ethernet MAC_address 0: 0xC835B842FAA2 RAM size: 1024 Mbytes Stop due to remain in basic/backup set

formathd /c2
All data on volume will be destroyed. Continue? y/n (n):y

Formatting Hard Disk...

$ reload -OSE Delta PowerPC/BL250206 Welcome to OSE Shell ose5.3. $ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT Plug-in Unit Product Name: DUW3001 Plug-in Unit Product No: KDU127161/3 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20110120 Plug-in Unit Product Serial: CB4G222342 Ethernet MAC_address 0: 0xC835B842FAA2 RAM size: 1024 Mbytes Stop due to remain in basic/backup set

ifconfig le0 169.254.1.1 netmask 255.255.0.0


$

1.1

Serial Connection Pin outs

2 from serial to 3 on RJ45 3 from serial to 2 on RJ45 5 from serial to 1 on RJ45

The connection between a DUW and a PC for serial connection (RS232) should look like this. Please note that

2) should look like this. Please note that this is applicable for DUW/DUL/DUG.

use FEMALE serial connector

output power st plugin txdev hscode get . Pool2

3-7-11 / 60 0-3/1-3 1-1/2-2/3-3/1/2/3 25/25 32574 32575 32576