This Product Comparison covers the following device terms and product codes as listed in ECRIs Universal Medical Device Nomenclature System (UMDNS): Electrocardiographs, Multichannel, Interpretive [16-231] Electrocardiographs, Multichannel, Interpretive, Signal-Averaging [18-330] Electrocardiographs, Multichannel, Noninterpretive [18-329] Electrocardiographs, Multichannel, Noninterpretive, Signal-Averaging [17-687] measurements on a screen and warn of potentially life-threatening or precursor rhythms. In addition, ECG monitors usually display only one or two leads of the ECG and provide less signal fidelity than an electrocardiograph. Like single-channel electrocardiographs, multichannel units are used to diagnose cardiac abnormalities,
Purpose
Electrocardiographs detect the electrical signals associated with cardiac activity and produce an ECG, a graphic record of the voltage versus time. They are used to diagnose and assist in treating some types of heart disease and arrhythmias. Electrocardiographs differ from ECG monitors, which provide a continuous display of the ECG waveform and other physiologic
231943 424-008
5200 Butler Pike, Plymouth Meeting, PA 19462-1298, USA Telephone +1 (610) 825-6000 G Fax +1 (610) 834-1275
E-mail hpcs@ecri.org
determine a patients response to drug therapy, and reveal trends or changes in heart function. Multichannel electrocardiographs record signals from two or more leads simultaneously and are frequently used in place of single-channel units. Multichannel electrocardiographs offer several advantages over single-channel electrocardiographs. They simplify and facilitate interpretation of the record by enabling the comparison of multiple-lead recordings during the same heartbeat; as a result, diagnostic accuracy is often improved. For example, an abnormal beat identified in two or more leads simultaneously can be ruled out as an artifact without the need to switch leads. By recording an entire 12-lead ECG in about 10 seconds (in the automatic mode), multichannel units save time and require less work than singlechannel recordings, which usually must be cut and mounted before examination by the cardiologist. Some electrocardiographs can perform automatic measurement and interpretation of the ECG as a selectable or optional feature; other units can be modified to include these programs. Interpretive electrocardiographs detect the electrical signals associated with cardiac activity, compare these signals with an internal algorithm, and print out the patients ECG along with an interpretation. The computerized interpretation is often accompanied by measurements of the waveform components. The measurements and interpretation are based on analyses similar to those done by the cardiologist. Because computerized interpretation can be inaccurate, however, this feature should be viewed as a tool that can aid in interpreting the ECG, not as a replacement for a physicians careful analysis.
Principles of operation
Electrocardiographs record small voltages of about one millivolt (mV) that appear on the skin as a result of cardiac activity. The voltage differences between
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
I RA LA
II
III
LL
V1
V2
V3
V4
V5
V6
C337UN3A
Precordial Leads
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Q Amplitude
S Amplitude
S Wave P-R Interval P Wave, QRS Complex, and T Wave QT Interval Next P Wave, QRS Complex, and T Wave
C337UN3B
Figure 2. A typical ECG signal consists of the P wave, QRS complex, and T wave. The duration and strength (amplitude) of these pulses directly correspond to the condition of the conduction pathways within the heart.
band of 0.05 to 100 Hz. Electrical interference from muscle movement or line-power frequency can produce artifacts on the recording; therefore, most units are equipped with filters to reduce such interference. Some units use notch filters at 60 Hz to filter out linefrequency noise. Many units also have electromyogram (EMG) filters to prevent artifacts from patient movement, which corrupt the ECG recording. Because these filters limit the frequency response, however, they can adversely affect diagnoses that are based on certain details (e.g., amplitude) that may be filtered out. Filters should be used sparingly because they often change the characteristics of the recorded ECG; they usually do not affect the signal used for interpretation. Signal averaging is available on some models. It eliminates ambient noise in the ECG signal to reveal high-frequency, low-amplitude signals (late potentials) that may appear at the end of the QRS complex of patients who have suffered a myocardial infarction (MI), have unexplained syncope, or who have a ventricular arrhythmia. The presence of late potentials is believed to be associated with an increased risk of sustained ventricular tachycardia a prime factor in sudden cardiac death and a syndrome that accounts for approximately half the mortality that follows recovery from acute MI. The electrocardiograph uses high-pass filters to remove low-frequency signals, leaving only the QRS complex. Noise in the complex that can mask late potentials is removed by comparing heartbeats to a template a model beat made during the initial recording that most closely represents an artifact-free normal beat; beats are accepted only if they closely match the template. Approximately 200 to 300 beats are digitized and averaged; electrical activity that does not correspond to the averaged signal, such as noise from equipment or other sources, is canceled out. While ECG tracings from single-channel units typically require cutting and mounting so that the interpreter can quickly examine a single beat in more than one lead, multichannel electrocardiographs usually require little report preparation time. With most multichannel units, no cutting or mounting is necessary because the operator can choose the desired report format (e.g., the number and duration of the leads recorded simultaneously, regardless of whether a rhythm lead is printed) before recording. Most units obtain all 12 leads simultaneously and then allow the operator to print copies of the ECG in any number of formats on 81/2 11-inch paper, which can be placed directly into a patients chart. Some multichannel units have alphanumeric touchpanel keyboards for entering patient data to be printed at the top of the ECG recording. Other data that can appear on the recording includes the time, lead identifiers, heart rate, and recording parameters (e.g., sensitivity setting, chart speed, filtered mode). Some units display the heart rate and alarm during episodes of tachycardia. Other alarms indicate artifacts, loose electrodes, empty paper, and improper paper loading. In addition, some units have special circuits to detect pacemaker spikes. Stress-testing protocols, trending,
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Purchase considerations
Electrocardiographs vary greatly in their degree of sophistication, and their capabilities should be consistent with the specific needs of the healthcare facility. Single-channel electrocardiographs, which record ECGs from one lead configuration at a time, are less expensive and generally smaller and lighter than their multichannel counterparts. However, single-channel systems generally require more technician time for recording, editing, and mounting the ECG for interpretation and filing. Multichannel electrocardiographs require less recording time, and many also eliminate the need for cutting and pasting because the ECG signals can frequently be printed in the desired format on 81/2 11-inch paper and placed directly in the patients chart. Many electrocardiographs perform some type of analysis on the ECG signal, such as waveform measurement or ventricular beat analysis, but not all units have complete interpretive software programs. The prospective buyer should be aware that only ECG units that specifically claim to have interpretive capability can generate diagnoses, reason statements, and recommendations for consultation or further testing (although, in some cases, the diagnostic software is available only as an option). Other factors to be considered when purchasing an electrocardiograph include ease of use, portability, type of paper required, clarity of recording, and cost of disposables such as electrodes and adhesives. Facilities should also keep in mind that some units can be interfaced to data management systems or to telephone modems for data transmission. To permit communication between the unit and other monitors or computers, models must have an RS232 port or other suitable digital interface. Optional carts make the units more transportable, provide a working surface for the user, and can hold spare lead wires, electrodes, and recording paper. Additional electrocardiograph features, such as automatic versus automatic/manual lead switching, availability (if desired) of stress-testing programs, and report format flexibility, should also be factored into the decision. Some bedside physiologic monitors have 12-lead ECG capability and can acquire diagnostic-quality ECG signals (with a frequency response of 0.05 to 100 Hz).
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Stage of development
To aid in the consistent recording of ECGs, AHA has published guidelines on electrocardiograph instrumentation, and the International Electrotechnical Commission and the Association for the Advancement of Medical Instrumentation have defined standards for electrocardiograph performance (see Standards and Guidelines). Advances in electrocardiograph technology have centered on automating and simplifying data collection, reducing the time needed to obtain clinically acceptable ECG measurements, and using microprocessors to interpret the ECG signal or transmit it to a remote computer. Several multichannel electrocardiographs with single-channel recording capabilities can measure and analyze the ECG waveform components and, from this information, diagnose cardiac conditions. Analytic programs for these microprocessor-controlled units can be a standard part of the basic instrument package or supplied as an option. ECG technology development is directed toward including data from other clinical monitoring devices in the analysis and interpretation of ECG signals to provide a more comprehensive diagnosis of the patients medical condition. ECG machines that provide faster, more accurate, and more comprehensive diagnoses will assume a major role in guiding cardiac therapy in the future.
Bibliography
Aronson MH, Saluja HC, eds. ECG recorders. Med Electron 1990 Apr;21(2):122-30. Bailey JJ, Berson AS, Garson A Jr, et al. Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association [special report]. Circulation 1990 Feb;81(2):730-9. Hsu K, Womble E, Tolan GD, et al. Simultaneous noise filtering and data compression of ECGs. Biomed Sci Instrum 1981;17:47-52. Pipberger HV, Arzbaecher RC, Berson AS, et al. Recommendations for standardization of leads and specifications for instruments in electrocardiography and
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Supplier information
Burdick Burdick Inc A Quinton Co [105481] 500 Burdick Pkwy Deerfield WI 53531 Phone: (608) 764-7179, (800) 777-1777, Fax: (608) 764-7188 E-mail: info@burdick.com Internet: http://www.burdick.com Cardio Control Cardio Control GmbH [306308] Obere Dammstrasse 8-10 D-42653 Solingen Germany Phone: 49 (212) 5875290 Fax: 49 (212) 5875299 E-mail: info@cardiocontrol.com Internet: http://www.cardiocontrol.com Cardio Control Inc [392254] 1870 The Exchange Suite 250 Atlanta GA 30339 Phone: (770) 818-0074, (800) 277-8544 Fax: (770) 818-0075 E-mail: info@cardiocontrol-us.com Internet: http://www.cardiocontrol-us.com Cardio Control NV [151053] Mercuriusweg 1 NL-2624 BC Delft The Netherlands Phone: 31 (15) 7505000 Fax: 31 (15) 7505050 E-mail: info@cardiocontrol.com Internet: http://www.cardiocontrol.com Cardio Control Sarl [366532] Parc Eurasante 256 avenue Eugene Avinee F-59120 Loos France Phone: 33 (3) 28559079 Fax: 33 (3) 28559077 E-mail: info@cardiocontrol.com Internet: http://www.cardiocontrol.com Cardioline/Remco Cardioline Inc [163053] 3200 Dutton Ave Unit 312 Santa Rosa CA 95407 Phone: (707) 547-1740, (800) 942-0442 Fax: (707) 547-1742 E-mail: info@cardiolineusa.com Internet: http://www.cardioline.us
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
CompuMed CompuMed Inc [101172] 5777 W Century Blvd Suite 1285 PO Box 45003 Los Angeles CA 90045-0003 Phone: (310) 258-5000, (800) 421-3395 Fax: (310) 645-5880 E-mail: ecg@compumed.net Internet: http://www.compumed.net
Control-X Medical Control-X Medical Inc [108554] 2289 Westbrooke Dr Bldg C Columbus OH 43228-9644 Phone: (614) 777-9729, (800) 777-9729 Fax: (614) 777-0395 E-mail: lhurd@cxmed.com Internet: http://www.cxmed.com
Custo Med Custo Med GmbH [284600] Leibnizstrasse 7 D-85521 Muenchen/Ottobrunn Germany Phone: 49 (89) 7109800 Fax: 49 (89) 7109810 E-mail: info@customed.de Internet: http://www.customed.de
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
10
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
11
12
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Note: The data in the charts derive from suppliers specifications and have not been verified through independent testing by ECRI or any other agency. Because test methods vary, different products specifications are not always comparable. Moreover, products and specifications are subject to frequent changes. ECRI is not responsible for the quality or validity of the information presented or for any adverse consequences of acting on such information.
When reading the charts, keep in mind that, unless otherwise noted, the list price does not reflect supplier discounts. And although we try to indicate which features and characteristics are standard and which are not, some may be optional, at additional cost. For those models whose prices were supplied to us in currencies other than U.S. dollars, we have also listed the conversion to U.S. dollars to facilitate comparison among models. However, keep in mind that exchange rates change often.
14
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
0.05-150 0.5-40
0.05-150 0.5-40
0.05-150 0.5-40
0.05-100 0.4-30
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
Meets or exceeds ANSI/AAMI Not specified Yes Digital thermal array Yes 8.5 x 11" Automatic Yes No 10, 25, 50
Meets or exceeds ANSI/AAMI Not specified Yes Digital thermal array Yes 8.5 x 11" Automatic Yes No 10, 25, 50
Meets or exceeds ANSI/AAMI Not specified Yes Digital thermal array Yes 8.5 x 11" Automatic Yes No 10, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
15
Yes 4
Yes 40
Yes 120
Not specified 30
NA Name, ID no., sex, age, date, time, weight, BP, location, medication, race, DOB, comments, physician, clinical classification, technician, facility, 1 useridentified field HR, PR, QRS, QT/QTC, P, R, T axis, QT dispersion
NA Name, ID no., sex, age, date, time, weight, BP, location, medication, race, DOB, comments, physician, clinical classification, technician, facility, 1 useridentified field HR, PR, QRS, QT/QTC, P, R, T axis, QT dispersion
MEASUREMENTS
HR, PR, QRS, QT/QTC, P, R, T axis, QT dispersion, RR, long interpretation statements Yes Yes Optional diagnosis, measurements, and reason statements
Yes Yes Optional diagnosis, measurements, and reason statements; gender specific
Analyzed waveform
Average
Average
Average
Median complex
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
13 Color LCD 12-lead LCD 3, 4, 6, 12 Noise, drift, lead fail, low battery
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
16
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
No 110/240 VAC
H x W x D, cm (in)
38.1 x 33.2 x 14 (15 x 13.1 x 5.5) 5 (11) Yes Ni-MH Not specified/14.4 1.5 Not specified
29.9 x 45.7 x 10.5 (11.8 x 18 x 4.1) 6.45 (14.2) Yes Ni-Cd Not specified/16.8 1.5 Not specified
125.7 x 43.4 x 65 (49.5 x 17.1 x 25.6) 39.5 (87) Yes Ni-Cd Not specified/16.8 1.5 Not specified
27.9 x 33 x 8.3 (11 x 13 x 3.3) 4.1 (9) Yes Ni-Cd Not specified/12.5 Not specified Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Selectable demographics; SCP-ECG compliant; upgradable via PC card; noninterpretive or interpretive.
Not specified Not specified Stress compatible; selectable demographics; SCP-ECG compliant; upgradable; interface to CardioVault EMR or ECG storage media on PC with Pyramis EMR system; long & brief interpretive statements; QTC calculations as selected by physician; reanalysis of ECG after stat ECG to QC data and classification.
Not specified Not specified Selectable demographics; SCP-ECG compliant; upgradable via PC card; standard interpretation that can be turned off; noninterpretive available; optional fax and communications modem; interface to Pyramis EMR system.
Colons separate data on similar models of a device. * $5,275 with interpretation (Eclipse 850); prices current as of October 2001.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
17
0.05-100 Digital, EMG-M1@40 Hz, M2@30 Hz, M3@25 Hz >100 >100 Yes Digital thermal head, 8 dots/mm Yes 60 mm (2.5") roll or z-fold paper Yes Yes No 6.25, 12.5, 25, 50
0.05-100 Digital, EMG-M1@40 Hz, M2@30 Hz, M3@25 Hz >100 >100 Yes Digital thermal head, 8 dots/mm Yes 112 mm (4.5"), z-fold paper Yes Yes No 6.25, 12.5, 25, 50
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
200 120 No Laser, matrix, or ink jet No 8.5 x 11", A4 Automatic Yes Yes 12.5, 25, 50
200 120 No Laser, matrix, or ink jet No 8.5 x 11", A4 Automatic Yes Yes 12.5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
15
15
12
12
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
18
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Yes 1
Yes 1
Unlimited Name, ID, age, sex, address, weight, height, BP, indication, medication, comments
Unlimited Name, ID, age, sex, address, weight, height, BP, indication, medication, comments
100 Name, ID no., DOB, sex, age, height, weight, physician, location
100 Name, ID no., DOB, sex, age, height, weight, physician, location
MEASUREMENTS
Analyzed waveform
Median complex
Median complex
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 sec to 5 min Yes Not specified Not specified Real-time display on monitor, battery status, pretrigger recording
10 sec to 5 min Yes Not specified Not specified Real-time display on monitor, battery status, pretrigger recording
10 Optional Delta-Vis Not specified 3 Loose contact, noise, low battery, incorrect data
10 Optional Delta-Vis Not specified 3 Loose contact, noise, low battery, incorrect data
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
19
Yes 9 V battery
Yes 9 V battery
H x W x D, cm (in)
28.5 x 18 x 5 (11.2 x 7.1 x 2) 0.95 (2.1) Yes Alkaline 1/9 >10 (600 ECGs) Not specified
17.5 x 10.5 x 3.5 (6.9 x 4.1 x 1.4) 0.4 (0.9) Yes Alkaline 1/9 >10 (600 ECGs) Not specified
31.3 x 23.9 x 11.4 (12.5 x 9.5 x 4.5) 2.8 (6.4) Yes Ni-Cd 1/12 1 8
31.3 x 23.9 x 11.4 (12.5 x 9.5 x 4.5) 2.8 (6.4) Yes Ni-Cd 1/12 1 8
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified January to December Meets requirements of AHA, ANSI/AAMI, CE, IEC, NEMKO, and TUV.
Not specified January to December Meets requirements of AHA, ANSI/AAMI, CE, IEC, NEMKO, and TUV.
NA/not specified Not specified Auto 3-channel printout in auto 2 mode; LCD displays HR, lead status, speed, gain, filter, battery status, and warning messages; 3-channel rhythm in manual mode; auto standby to save battery; autotest at power on; manual autotest; alter parameters to improve copy quality; doctor/ facility name possible on all ECGs. Meets requirements of IEC 601-1.
NA/not specified Not specified Auto 3-channel printout in auto 2 mode; LCD displays HR, lead status, speed, gain, filter, battery status, and warning messages; auto standby to save battery; autotest at power on; manual autotest; recording parameters can be modified to improve copy quality; name of doctor or clinic can be preprogrammed to print on all ECGs.
20
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Automatic/manual 5, 10 Automatic
0.05-100 Digital, EMG-M1@40 Hz, M2@30 Hz, M3@25 Hz >100 >100 Yes Digital thermal head, 8 dots/mm Yes 210 x 270 mm (8.5 x 11") roll or z-fold paper Yes Yes No 6.25, 12.5, 25, 50
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>100 >100 Yes Digital thermal head, 8 dots/mm Yes 210 mm z-fold paper Yes Yes No 6.25, 12.5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
Not specified
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
21
Yes 1
Rest ECG; opt interpretation/measurement, stress test, arrhythmia monitor Yes 100
Resting
Not specified 1
100 Name, ID no., DOB, sex, age, height, weight, physician, location
Unlimited with optional PC card Name, ID no., DOB, sex, age, race, height, weight, BP, physician, medications, others
30 Patient name, ID no., sex, age, height, weight, race, 2 medication entries/patient (9 categories), date, time, optional location
Not specified NA
MEASUREMENTS
No
NA NA No
Analyzed waveform
Median complex
Median complex
Not specified
NA
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 Optional Delta-Vis Not specified 3 Loose contact, noise, low battery, incorrect data
10 Yes Yes 6/12 Loose contact, battery level, printer errors, bad data
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
22
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Yes 100-240 VAC, 50/60 Hz 28.6 x 29.2 x 9.5 (11.3 x 11.5 x 3.8) 5 (11) Yes Rechargeable Not specified ~4 8
H x W x D, cm (in)
40.6 x 29.2 x 12.7 (16 x 11.5 x 5) 5.8 (13) Yes Ni-Cd 1/12 1 8
26 x 12.5 x 5.5 (10.2 x 4.9 x 2.2) 1.5 (3.3) Yes Ni-Cd rechargeable 5/6 0.5 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
NA/not specified Not specified 3- and 6-channel printout w/interpretation; LCD displays HR, lead status, warning messages; standby to save battery; modifiable recording parameters; alphanumeric keypad; firmware for stress testing; Delta-Link for ECG management. Meets requirements of IEC 601-1.
0 Not specified User-defined recording modes, shortkey operations; saving and sending special keys; removable paper drawer; integrated cart and carrying bag available.
NA/200 January to December Computer software for storing and retrieving ECG curves.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
23
0.05-250 Yes
0.05-250 Yes
0.02-100 Yes
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
20+ 90 Yes Digital thermal array Yes 112 mm Yes Yes No 5, 25, 50, 100
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
No Not specified Not specified Not specified Not specified Not specified
No Not specified Not specified Not specified Not specified Not specified
12
12
12
2-3
3 Yes Cable to PC
Not specified No NA
Not specified No NA
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
24
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Adult resting
Adult and pediatric resting ECG, optional stress testing Not specified Depends on PC capacity
Adult and pediatric resting ECG, optional stress testing Not specified Depends on PC capacity
Not specified
Depends on PC capacity Name, ID no., DOB, race, sex, age, height, weight, BP, medication
Depends on PC capacity Name, ID no., DOB, race, sex, age, height, weight, BP, medication
MEASUREMENTS
Analyzed waveform
Median complex
Median complex
Median complex
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
25
Yes 110/230 VAC or rechargeable batteries 31 x 24 x 7 (12.2 x 9.4 x 2.8) 2.8 (6.2) Yes Rechargeable Not specified Varies Not specified
H x W x D, cm (in)
9.8 x 6.5 x 2.2 (3.9 x 2.6 x 0.9) 0.11 (0.2) without batteries Yes See footnote * 2/1.5 24 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified January to December Integrated parameter recognition; realtime ECG analysis; data transfer from computer to recorder via infrared technology.
Colons separate data on similar models of a device. * Mignon cells or rechargeable batteries.
26
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
Not specified 125 mm No No No 1.25, 2.5, 5, 10, 12.5, 25, 50, 100
Not specified 150 mm No No No 1.25, 2.5, 5, 10, 12.5, 25, 50, 100
3 No NA
3 No NA
3 No NA
3 No NA
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
27
Stress testing
Stress testing
Not specified
Not specified
No Not specified
No Not specified
No Not specified
No Not specified
MEASUREMENTS
Not specified
Not specified
Not specified
Not specified
Analyzed waveform
NA
NA
NA
NA
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
NA No No NA None specified
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
28
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
H x W x D, cm (in)
Not specified
Not specified
12.7 x 31.8 x 27.9 (5 x 12.5 x 11) 5.9 (13) Yes Ni-Cd 1/12 3 NA
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Add-on module capability; auto baseline correction and pen centering; pacemaker pulse protection circuit; self-check; HR and tachycardia alarm optional. Meets requirements of CSA, IEC, OSHA, and UL 544.
Not specified Not specified Add-on module capability; auto baseline correction and pen centering; pacemaker pulse protection circuit; self-check; HR and tachycardia alarm optional. Meets requirements of CSA, IEC, OSHA, and UL 544.
Not specified Not specified Alphanumeric printer. Meets requirements of CSA, IEC, OSHA, and UL 544.
Not specified Not specified Alphanumeric printer. Meets requirements of CSA, IEC, OSHA, and UL 544.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
29
Automatic/manual 5, 10, 20 1 mV
270 0-150
270 0-150
270 0-150
0-150 0-150
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>50 100 Yes Separate optional thermal printer, laser printer No A4/letter Yes Yes Yes 5, 12.5, 25, 50
>50 100 Yes Separate optional thermal printer, laser printer Not specified A4/letter Yes Yes Yes 5, 12.5, 25, 50
>50 100 Yes Separate optional thermal printer, laser printer Optional A4/letter Yes Yes Yes 5, 12.5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
3 No NA
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
30
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Optional interpretative SW, LPA, RRV, and stress package Not specified 140 floppy (rest ECG), 50,000 hard drive, 200 stress
Optional interpretative SW, LPA, RRV, and stress package Not specified 140 floppy (rest ECG), 50,000 hard drive, 200 stress
Interpretative SW and stress package, optional LPA and RRV Not specified 140 floppy (rest ECG), 50,000 hard drive, 200 stress
Not specified Name, ID no., DOB, race, sex, age, height, weight, BP, medications, physician notes
NA Name, ID no., DOB, race, sex, age, height, weight, BP, medications, physician notes
MEASUREMENTS
32 ECG parameters
15 ECG parameters
Analyzed waveform
Median complex
Median complex
Median complex
Median complex
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
Not specified 9" LCD B/W Not specified Electrode contact, battery/main status, chart speed, filter status
10 SVGA monitor Not specified Not specified Electrode contact, battery/main status, chart speed, filter status
10 No Not specified Not specified Electrode contact, battery/main status, chart speed, filter status
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
31
H x W x D, cm (in)
32.8 x 25.4 x 7.5 (13 x 10 x 3) 3.8 (8.4) Yes Ni-Cd 1/12 1 Not specified
32.8 x 25.4 x 7.5 (13 x 10 x 3) 4.8 (1.8) Yes Ni-Cd 1/12 1 Not specified
78 x 66 x 144 (30 x 26 x 57) 80 (176.4) Yes Ni-Cd 1/12 Only for backup Not specified
29.6 x 56 x 72.5 (12 x 22 x 29) 2.9 (6.4) Yes Lead acid 1/12 2 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Fully automatic; large configurability; trolley for rest; connects to SVGA color monitor; direct connection to PC for Windows printouts.
Not specified Not specified Fully automatic; large configurability; trolley for stress and rest; connects to SVGA color monitor; direct connection to laser printer.
Not specified Not specified Fully automatic; configurable; direct connection to laser printer; LPA and RRV options.
32
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Automatic/manual 5, 10, 20 1 mV
Automatic/manual 5, 10, 20 1 mV
Automatic/manual 5, 10, 20 1 mV
Automatic/manual 5, 10, 20 1 mV
0-150 0-150
0-150 0-150
0-150 0-150
0-150 0-150
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>15 100 Yes Thermal printer, external PC printer Yes Z-fold 90 x 70 mm, 90 mm roll, A4 Yes Yes Yes 5, 25, 50
>15 100 Yes Thermal printer, external PC printer Optional 210 x 280 mm Yes Yes Yes 5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
3, 6, 12 Yes Serial
3, 6, 12 No NA
3, 12 No NA
3, 6, 12 Yes Serial
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
33
Optional adult and pediatric interpretation, rest spirometry Not specified 45, internal memory
Optional adult and pediatric interpretation, stress test, rest spirometry Not specified 45, internal memory
Not specified Name, ID no., DOB, race, sex, age, height, weight, BP, medications, physician notes
NA Name, ID no., DOB, race, sex, age, height, weight, BP, medications, physician notes
Not specified Name, ID no., DOB, race, sex, age, height, weight, BP, medications, physician notes
MEASUREMENTS
15 ECG parameters
15 ECG parameters
Yes
32 ECG parameters
Analyzed waveform
Median complex
Median complex
Not specified
Median complex
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 LCD 120 x 90 mm Not specified Not specified Electrode contact, battery/main status, chart speed, filter status
10 No Not specified Not specified Electrode contact, battery/main status, chart speed, filter status
10 9" LCD Not specified Not specified Electrode contact, battery/main status, chart speed, filter status
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
34
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
H x W x D, cm (in)
39.9 x 33.8 x 10.5 (16 x 13 x 4) 5 (11) Yes Lead acid 1/12 4 Not specified
39.9 x 33.8 x 10.5 (45.7 x 13.3 x 4.1) 4.2 (9.4) Yes Lead acid 1/12 6 Not specified
29.6 x 22 x 72.5 (11.7 x 8.7 x 28.5) 2.9 (6.4) Yes Lead acid 1/12 2 Not specified
39.9 x 33.8 x 10.5 (15.7 x 13.3 x 4.1) 5 (11) Yes Lead acid 1/12 4 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified 1-key operation; 2 automatic pre-set formats; time and date; automatic recognition of external printer; intelligent filtering applicable on recorded signal; 2 units in 1 desk.
Not specified Not specified 1-key operation; 2 automatic pre-set formats softkey; automatic paper drawer.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
35
0.05-150 50/60 Hz AC, 25/35 Hz muscle, 0.25/0.5 Hz drift 50 >103 Yes Thermal array
0.05-150 50/60 Hz AC, 25/35 Hz muscle, 0.25/0.5 Hz drift 50 >103 Yes Thermal array
0.05-150 50/60 Hz AC, 25/35 Hz muscle, 0.25/0.5 Hz drift 50 >103 Yes Thermal array
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
1, 3
12
12
12
12 Yes RS232C
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
36
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Adult and pediatric resting ECG, stress testing Not specified 1,000 with IC card (20 MB)
Not specified NA
Adult and pediatric resting ECG, optional stress testing Not specified 1,000 with IC card (20 MB)
NA ID no., age, sex, height, weight, ward, department, meds, symptoms, BP, race, comments
MEASUREMENTS
Analyzed waveform
Not specified
Not specified
Not specified
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 No LCD Not specified Loose contact, ID no., sex, age, HR, sensitivity, filter, battery
10, 20 Yes LCD w/back light Not specified Loose contact, ID no., sex, age, HR, sensitivity, paper speed, filter, battery, message
10, 20 Yes LCD w/back light Not specified Loose contact, ID no., sex, age, HR, sensitivity, paper speed, filter, battery, message, IC card
10, 20 Yes LCD w/back light Not specified Loose contact, ID no., sex, age, HR, sensitivity, paper speed, filter, battery, IC card, function keys
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
37
H x W x D, cm (in)
6.3 x 26 x 18.2 (2.5 x 10.2 x 7.2) 2.4 (4.4) Yes Not specified 1/9.6 1 Not specified
6.5 x 29.7 x 21 (2.6 x 11.7 x 8.3) 4.5 (9.9) Yes Not specified 1/9.6 1 Not specified
10.1 x 37.8 x 33.8 (4 x 14.9 x 13.3) 8 (17.6) Optional Not specified 1/9.6 1 Not specified
6 x 26 x 19.5 (2.4 x 10.2 x 7.7) 2.6 (5.7) Optional Ni-MH 1/9.6 0.5 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
NA/not specified Not specified Built-in handle for portability; quickcharge battery; touchscreen operation.
NA/not specified Not specified 2 modular inputs for optional features; data storage on IC card; arrhythmia analysis; 12-lead cubic expression display.
NA/not specified Not specified Arrhythmia analysis; 12-lead cubic expression display; full key and touchscreen operation.
38
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
0.05-150 50/60 Hz AC, 25/35 Hz muscle, 0.25/0.5 Hz drift 50 >103 Yes Thermal array
0.05-150 0.05-35, 0.05-25, 0.3-25, 0.3-35, 0.15-25, 0.15-35 100 100 Yes Digital thermal array Not specified 3.5" wide roll or 3.5 x 2.7" z-fold Yes Yes No 5, 25, 50
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
100 100 Yes Thermal printer, laser printer Not specified 8.5 x 11" Yes Yes Yes 5, 12.5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
Not specified 8.5 x 11" Yes Yes Not specified 5, 10, 25, 50
12
12
12
12
3 No NA
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
39
Adult and pediatric resting ECG, optional stress testing Not specified 300 (built-in memory), 1,000 with IC card (20 MB)
Not specified
Not specified
Not specified 12
No 12
Yes 45
NA ID no., age, sex, height, weight, ward, department, meds, symptoms, BP, race, comments, name
MEASUREMENTS
Yes
Optional
Analyzed waveform
Not specified
Not specified
Not specified
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10, 20 Yes LCD, ext backlit Not specified Loose contact, ID no., sex, age, HR, sensitivity, paper speed, filter, battery, IC card, function keys, message
10 No No NA Lead off, battery, 12-lead ECG tracing, demographics, paper speed, loose leads
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
40
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
H x W x D, cm (in)
10 x 33.5 x 34.6 (3.9 x 13.2 x 13.6) 6 (13.2) Optional Ni-MH 1/9.6 1 Not specified
32.8 x 25.4 x 7.5 (12.9 x 10 x 3) 3.8 (8.4) basic ECG; 4.8 (10.6) stress Yes Ni-Cd 1/12 3 Not specified
6.9 x 29 x 21 (2.7 x 11.4 x 8.3) 2.9 (6.4) Yes Lead acid 1/12 3 Not specified
33.9 x 33.8 x 10.4 (13.4 x 13.3 x 4.1) 4.3 (9.5) Yes Lead acid 1/12 2 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified 2 years, parts and labor Not specified Not specified Not specified
NA/not specified Not specified Arrhythmia analysis; 12-lead cubic expression display; full key and touchscreen operation; data storage on IC card and built-in memory; external display.
Not specified June to June Page-formatted long-term rhythm recording; monitor output; upgradable to interpretive ECG. Meets requirements of AHA and IEC 601-1.
Not specified June to June 1-touch operation; automatic baseline centering; optional measurement module; customizable setup; 1,000 Hz sampling rate. Meets requirements of AHA and IEC 601-1.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
41
Automatic/manual/ stress test 5, 10, 20, 40 Automatic/manual/ stress test 0.05-150 0.05-20/35 muscle, 0.05-50/60 main
Automatic/manual/ stress test 5, 10, 20, 40 Automatic/manual/ stress test 0.05-150 0.05-20/35 muscle, 0.05-50/60 main
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
100 >100 Yes PC Windows-supported printers No 8.5 x 11", A4 Yes Yes Yes 25, 50, 100
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
Not specified 210 x 300 mm or 216 x 280 mm Yes Yes Yes 25, 50
Not specified 210 x 300 mm or 216 x 280 mm Yes Yes Yes 5, 10, 25, 50, 100
12
12
12
12
12 No NA
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
42
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Not specified
Adult resting ECG, stress testing, signal-averaged ECG PC keyboard 50,000 reports with waveforms
Not specified
Not specified
No 12
Unlimited Name, ID, age, sex, weight, height, address, physician, date, time, indication, medication, comments
MEASUREMENTS
Optional
Analyzed waveform
Not specified
Not specified
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
NA No No NA Not specified
10 Print preview PC monitor, laptop 1-12 Real-time display on monitor, filters, speed, gain, HR, date, time, patient name, ID, lead identification, printing format
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
43
Yes 5 V, provided by the PC/laptop through USB 3 x 6.3 x 14 (1.2 x 2.5 x 5.5) not including PC 0.23 (0.5), not including PC No NA NA NA NA
H x W x D, cm (in)
33.9 x 33.8 x 10.4 (13.4 x 13.3 x 4.1) 5 (11) Yes Lead acid 1/12 2 (full charge) Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Not specified Not specified Not specified
Not specified Not specified Not specified Not specified Not specified
NA/not specified March to February Link to PC using USB port; Windows 98/00/ NT; cardiac stress test SW; optional VLP analysis.
Not specified May to April List price set according to country; PC-based software with CORINA; spirometry; holder BP; late potentials.
Not specified May to April List price set according to country; PC-integrated; right-heart catheterization; spirometry; holder BP; late potentials.
44
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Automatic/manual, stress test 2.5, 5, 10, 10/5, 20 Automatic, -3 dB @ 0.01-150 Hz 0.01-150 Notch, EMG
0.05-100 50/60 Hz AC, 25-35 Hz muscle, baseline drift >10 100 Yes PC hard drive
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>100 100 Yes Digital thermal printer Yes A4 z-fold or roll Yes Yes No 1.25, 2.5, 5, 10, 12.5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
15
12
12
3, 6, 12 Yes Modem
12 Yes Internet
3, 4, 5, 12 Yes RS232
Colons separate data on similar models of a device. * Model(s) listed are currently marketed; specifications current as of October 2001. ** 35 Hz at 6 dB/octave, modified 50 Hz notch, antidrift-phase high-pass filter without trace distortion.
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
45
Adult, pediatric
Adult, pediatric
Not specified 45
Adult and pediatric resting ECG, optional stress testing Not specified Unlimited
Not specified 1
NA Name, age, ID, sex, weight, height, race, date, location, time, medication
NA Name, age, ID, sex, weight, height, date, location, time, medication, chart speed, sensitivity filter
Unlimited Name, ID no., DOB, sex, age, height, weight, BP, medications, address, 2 telephone numbers, gatekeeper/physician
MEASUREMENTS
Yes
Yes
QRS, PQ, QTC, (QT corrected seconds), ST-segment take-off, QRS axis, Q/R, R/S, P, HR Yes Yes Diagnosis, measurements, reason statements
Analyzed waveform
Median complex
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 PC screen PC screen Not specified Loose contact, noise, low battery, bad data
10 Yes Not specified Not specified Antidrift, power supply, low battery, clamp, overload, loose contact, end paper, door open, automatic centering, chart speeds, sensitivity, filter, operating mode
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
Colons separate data on similar models of a device. * Model(s) listed are currently marketed; specifications current as of October 2001.
46
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Yes 110-120/220-240 VAC, 50/60 Hz 6.2 x 34.7 x 32.8 (2.4 x 13.7 x 12.9) ~4.5 (9.9) Yes Rechargeable Not specified 40 min Not specified
H x W x D, cm (in)
14.5 x 3.7 x 12.6 (5.7 x 1.5 x 5) 5.6 (12.3) Yes Ni-Cd 1/18 @ 1.3 AHr 50 pages ~4
9.4 x 38.1 x 35.1 (3.7 x 15 x 13.8) 6.8 (15) Yes Ni-MH 1/18 @ 3.5 A-hr 15% 6 cont display or 100 single-page rpt ~4.5 from total discharge-no display Not specified 1 year Immediate Not specified Not specified
3.5 x 15.9 x 9.5 (1.4 x 6.3 x 3.7) 0.34 (0.75) Optional 9 V or rechargeable 1/9 2 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified January to December Graphics display; software cartridges for field upgradability; optional carrying case.
Not specified January to December Multiple recording formats; transmits/ receives data to/ from ECG cart and MUSE data management system.
Not specified January to December Data transfer via BDT, GDT, HL7; pacemaker pulse detection and protection; defibrillator protection, marker.
Not specified Not specified Alphanumeric keyboard; LCD display; upgrade at any time; optional stress-test protocol, remote tx (SCP protocol), 70tracing memory, and PC connections. Meets requirements of EN 60601-1/-1-2/ -2-25 and IEC 62D-WG1(263)WD.
Colons separate data on similar models of a device. * Model(s) listed are currently marketed; specifications current as of October 2001. ** 2 channels 0-10 V (analog); 1 TTL output channel with programmable polarity delay and width; VGA.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
47
0.05-100 Notch/EMG
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
Not specified Not specified Not specified Digital thermal printer Yes 104 mm Yes Yes Not specified 5, 25, 50
>100 100 Yes Digital thermal printer Not specified A4 z-fold or roll Yes No No 5, 25, 50
>100 100 Yes Digital thermal printer Yes A4 z-fold or roll Yes No No 5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
3, 6 Yes Modem
3, 6 No NA
3, 6 Yes RS232
1 or 3 No NA
Colons separate data on similar models of a device. * Model(s) listed are currently marketed; specifications current as of October 2001. ** Africa, Asia, Asia Pacific, Europe, Middle East, South America. *** 35 Hz at 6 dB/octave, modified 50 Hz notch, antidrift-phase high-pass filter without trace distortion.
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
48
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Not specified
Not specified 80
Not specified 1
No Not specified
Not specified Name, ID no., age, sex, BP, height, weight, date, comments, location
MEASUREMENTS
QRS, PQ, QTC, (QT corrected seconds), ST-segment take-off, QRS axis, Q/R, R/S, P, HR Not specified Not specified Diagnosis, measurements, reason statements
QRS, PQ, QTC, (QT corrected seconds), ST-segment take-off, QRS axis, Q/R, R/S, P, HR Yes Yes Diagnosis, measurements, reason statements
No
NA NA No
Analyzed waveform
Not specified
NA
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 Optional Not specified Not specified Antidrift, power supply, low battery, clamp, overload, loose contact, end paper, door open, automatic centering, chart speeds, sensitivity, filter, operating mode
10 Yes Not specified Not specified Antidrift, power supply, low battery, clamp, overload, loose contact, end paper, door open, automatic centering, chart speeds, sensitivity, filter, operating mode
Colons separate data on similar models of a device. * Model(s) listed are currently marketed; specifications current as of October 2001.
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
49
Not specified 110-120/220-240 VAC, 50/60 Hz 6.5 x 30 x 21.8 (2.6 x 11.8 x 8.6) 3 (6.6) Yes Rechargeable Not specified Not specified Not specified
Yes 110-120/220-240 VAC; 50/60 Hz 6.2 x 34.7 x 32.8 (2.4 x 13.7 x 12.9) ~4 (8.8) Yes Rechargeable Not specified 40 min Not specified
Yes 110-120/220-240 VAC; 50/60 Hz 6.2 x 34.7 x 32.8 (2.4 x 13.7 x 12.9) ~4 (8.8) Yes Rechargeable Not specified 40 min Not specified
Yes 2 main and rechargeable batteries 21 x 16.5 x 4.5 (8.3 x 6.5 x 1.8) 1.5 (3.3) Yes Lead acid Not specified/6.3 Not specified 3
H x W x D, cm (in)
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Remote tx (SCP protocol); PC connection with optional software. Meets requirements of EN 60601-1/-2-25 and NEMKO.
Not specified Not specified User name; mask for patient data; different report formats; copy of the stored tracing. Meets requirements of EN 60601-1/-1-2/ -2-25 and IEC 62D-WG1(263)WD.
Not specified Not specified Real-time PC connection with optional software. Meets requirements of EN 60601-1/2-25 and IEC 62D-WG1(263)WD.
Not specified June to July Meets specifications of AS3200 and IEC 601-2-25.
Colons separate data on similar models of a device. * Model(s) listed are currently marketed; specifications current as of October 2001.
50
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
0.05-100 Notch/EMG
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>100 100 Yes Microsoft Windowssupported printers No 8.5 x 11", A4 Yes Yes Not specified 10, 25, 50, 100 display; 25 print
>100 100 Yes Microsoft Windowssupported printers No 8.5 x 11", A4 Yes Yes Not specified 25
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
12 Yes Modem
3x4+1 rhythm, 3x4+3 rhythm, 6x2, 12 Yes Fax, e-mail, FTP, reports, network
3x4+1 rhythm, 3x4+3 rhythm, 6x2, 12 Yes Fax, e-mail, FTP, reports, network
Colons separate data on similar models of a device. * Africa, Asia, Asia Pacific, Europe, Middle East, South America.
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
51
Not specified
200 max floppy disk; more on PC hard disk Name, ID, DOB, sex, age, height, weight, medications, doctor and cardiologist comment, ECG referral status
Unlimited Name, ID, age, sex, medication, BP, history, location, physician, race, date, comments, technician, vitals
MEASUREMENTS
HR, QRS axis, P axis, QRS, PR, and QT duration automatic; all/any of the above manual Database Not specified Rhythm analysis, measurements, interpretation
Continuous
Analyzed waveform
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
9/lead PC screen LCD Not specified Loose contact, noise, low battery, bad data
10 Yes Yes 3x4+1 rhythm, 4, 12 Noise, loose contact, report status, filters, speed, gain, HR, BP, date, time, patient name, ID, lead identification, lead off, online editing
10 Yes Yes 3 Noise, loose contact, report status, filters, speed, gain, HR, BP, date, time, patient name, ID, lead identification, lead off, online editing
Colons separate data on similar models of a device. * Name, patient ID, race, sex, BP, weight, height, age, physician, technician, date of report, reviewed by, review date, history, medication, comments.
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
52
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Yes 2 main and rechargeable batteries 21 x 16.5 x 4.5 (8.3 x 6.5 x 1.8) 1.5 (3.3) Yes Lead acid Not specified/6.3 Not specified Not specified
Yes 3 VDC
Yes 3 VDC
H x W x D, cm (in)
10 x 8.7 x 2.4 (4 x 3.4 x 0.9) 0.2 (0.4) Yes AA/Ni-Cd; Ni-MH 2/3 >25 Not specified
2.3 x 7.1 x 12.7 (0.9 x 2.8 x 5) without PC 0.3 (0.7) without PC Yes Alkaline 2/1.5 60 Not specified
2.3 x 7.1 x 12.7 (0.9 x 2.8 x 5) w/o handheld device 0.3 (0.7) without handheld device Yes Alkaline 2/1.5 60 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
1,400 (US$2,208) 2 years, extended avail on recorder Not specified Not specified Not specified
Not specified June to July Meets specifications of AS3200 and IEC 601-2-25.
Not specified Not specified List price is for UK only; price varies by country.
Not specified Not specified Link to PC using standard serial or USB port connections; fax/modem transmission; Windows 95/98/ME/2000/ NT/XP; SQL server database; peer-topeer network database; auto save of patient data/test; full online review and editing features, including zooms, electronic calipers, customizable list of diagnostic statements, indications, others.
Not specified Not specified Supports MS Pocket PC 2002 handheld devices; also links to PC using standard serial or USB port connections; supports Windows 95/98/ ME/2000/NT/XP; SQL server database; peer-to-peer network database; autosave of patient data/ test; fax/modem transmission; full online review and editing features, including zooms, electronic calipers, customizable list of diagnostic statements, indications, others.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
53
0.05-300 0.05-40
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
47 130-210 Yes Digital thermal array Yes 108 mm x 30 m Yes Yes No 5, 10, 25, 50
49 130-210 Yes Digital thermal array Yes 8.5 x 11" Automatic Yes No 5, 10, 25, 50
See footnote * See footnote * Yes Digital thermal array Yes A4, 8.5 x 11" Yes Yes No 5, 10, 25, 50
See footnote * See footnote * Yes Digital thermal array writer or laser printer Detachable 8.5 x 11" Automatic Yes No 5, 10, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
Colons separate data on similar models of a device. * Meets requirements of AAMI/ANSI standard EC-11a (1985, revised 1992) and IEC 601 for diagnostic ECG.
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
54
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Alphanum/functions Up to 60 (internal)
NA Name, ID no., age, sex, height, weight, race, medications, date, time, room, location, comment; custom ID available with data management system
Up to 300 Name, ID no., age, sex, height, weight, race, medications, date, time, room, location, comment; custom ID available with data management system
NA Name, ID no., age, sex, DOB, custom ID available with data management system
NA Name, ID no., age, sex, height, weight, race, medications, date, time, room, location, comment; custom ID available with data management system
MEASUREMENTS
HR, PR, QRS, QT/QT, P, QRS and T axis, full measurement matrix
HR, PR, QRS, QT/QT, P, QRS and T axis, full measurement matrix
HR, PR, QRS, QT/QTc, P, QRS and T axis, full measurement matrix
HR, PR, QRS, QT/QT, P, QRS and T axis, full measurement matrix
Analyzed waveform
Median complex for contour analysis, rhythm-for-rhythm analysis 10 No Not specified Not specified System status, battery status, lead fail, noisy data, loose contact, reverse leads, writer door status, out of paper
Median complex for contour analysis, rhythm-for-rhythm analysis 10 No Not specified Not specified System status, battery status, lead fail, noisy data, loose contact, reverse leads, writer door status, out of paper
Median complex for contour analysis, rhythm-for-rhythm analysis 10 Yes Not specified Up to 8 System status, battery status, lead fail, noisy data, reversed leads, writer door status, out of paper
Median complex for contour analysis, rhythm-for-rhythm analysis 10 10.4" color LCD Not specified Not specified System status, battery status, lead fail, noisy data, loose contact, reverse leads, out of paper
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
55
H x W x D, cm (in)
9.5 x 28.6 x 29.2 (3.8 x 11.3 x 11.5) 4.9 (11) Yes Gel cell Not specified 4 (>1,000 ECG), rechargeable battery Not specified
12.1 x 43.8 x 35.6 (4.8 x 17.3 x 14) 11.3 (25) Yes Gel cell Not specified 4 (>1,000 ECG), rechargeable battery Not specified
8.9 x 38.1 x 43.2 (3.5 x 15 x 17) 4.5 (10) with battery Yes Gel cell Not specified Not specified Not specified
See footnote *
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified 1 year, parts and labor Not specified Yes 2003
Not specified 3 years mail-in or 1 year on-site Immediate Not specified Not specified
Not specified Not specified Simultaneous 12-lead acquisition; artifact filter; multiple print formats; >1,000 ECGs/ battery charge; X-12 wireless patient cable, internal modem.
Not specified Not specified Simultaneous 12-lead acquisition; artifact filter; multiple print formats; >1,000 ECGs/ battery charge; X-12 wireless patient cable, internal modem, serial comparison, and expanded ECG storage optional.
Not specified Not specified Simultaneous 12-lead acquisition; multiple print formats; waveform preview; large paper tray; short form instruction card on writer cover; patient directory sorted by user preference; internal modem; pre-populate ID entry via patient directory; internal storage.
Not specified Not specified Simultaneous 12-lead acquisition; highresolution color LCD for display of all 12 leads; sourceconsistency filter; multiple print formats; X-12 wireless patient cable; serial comparison; internal modem optional.
Colons separate data on similar models of a device. * 5.3 x 33 x 27.9 cm (2.1 x 13 x 11 in), monitor and writer; 3.6 x 26.7 x 27.9 cm (1.4 x 10.5 x 11 in), monitor only. ** 4.5 kg (10 lb), monitor and writer; 1.8 kg (4 lb), monitor alone.
56
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
0.05-120 or higher 50/60 Hz line filters, 40 Hz muscle tremor, baseline >100 >120 Real time, reversal Laser, ink jet, dot matrix, any PC printer PC printer Depends on printer Automatic Yes Yes 25, 50
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
Exceeds standards Exceeds standards Yes Digital thermal array Yes 8.5 x 11" Automatic Yes No 5, 10, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12 : 12 : 12, 15
12
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
57
Adult resting ECG, serial comparison, signal-line averaging, 12-lead Holter Not specified Up to 300
NA Name, ID no., age, sex, height, weight, race, medications, date, time, room, location, comment; custom ID available with data management system
Unlimited Name, SSN, age, sex, medications, physicians, height, weight, address, full chart, more available
9,600 (ECG-9320A) ID, name, age/birthdate, sex, height, weight, race, BP (systolic and diastolic)
NA ID
MEASUREMENTS
HR, PR, QRS, QT/QT, P, QRS and T axis, full measurement matrix
HR, R-R, P duration, PR interval, QRS duration, P/R/T axes, QT/QTC, electronic caliper for manual measurement * Via Holter module Yes ** Diagnostic, global and full measurements, electronic caliper, reason statements, serial comparisons Medical complex
No No Optional
Analyzed waveform
Median complex for contour analysis, rhythm-for-rhythm analysis 8 Yes Not specified Not specified System status, battery status, lead fail, noisy data, loose contact, reverse leads, writer door status, out of paper
Yes
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
12 Yes PC monitor (CRT/LCD) Not specified Loose contact, failed lead, noise, bad data
10 Yes 12-lead Not specified Low battery, leads off, paper empty
2.5 LCD Not specified Not specified Lead off, low battery
Colons separate data on similar models of a device. * Also ST slope/elevation. ** Resting, historical/serial comparisons, stress summary and complex reports, Holter summary reports, ECG reports, etc.
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
58
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
H x W x D, cm (in)
53.3 x 36.8 x 11.4 (21 x 14.5 x 4.5) 13.6 (30) Yes Gel cell Not specified 4 Not specified
5.1 x 10.2 x 11 (2 x 4 x 5) 0.7 (1.5) No Uses PC power Uses PC power Uses PC power Uses PC power
17.3 x 42.5 x 15.7 (6.8 x 16.7 x 6.2) 13.8 (30.4) Yes Lead acid 1/12 0.5 1 : 0.5 : 0.5
6.1 x 17 x 20.3 (2.4 x 6.7 x 8.2) 1 (2.2) Yes Ni-MH Not specified 1 Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Simultaneous 12-lead acquisition; high-resolution LCD for display of all 12 leads; sourceconsistency filter; multiple print formats; optional X-12 wireless patient cable, internal modem, stress testing, 12-lead Holter monitoring, and signal averaging.
Not specified Not specified Integrated patient record database; clinical ECG management system; telecommunication utility; remote monitoring software; EMR chart, stress option, Holter opttion; NIBP, SpO2, temperature.
Not specified April to April RS232C ports; optional modem connections, flashcard storage, and stress-test recording.
Not specified Not specified Meets requirements of CSA, TUV, and UL.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
59
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
100 110 Yes Digital thermal array Yes 8.5 x 11", A4 Automatic Yes No 5, 10, 25, 50
100 110 Yes Digital thermal array Yes 8.5 x 11", A4 Automatic Yes No 5, 10, 25, 50
100 110 Yes Digital thermal array Yes 8.5 x 11", A4 Automatic Yes No 5, 10, 25, 50
100 Not specified Yes Digital thermal array Yes 8.5 x 11", A4 Automatic Yes No 5, 10, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
16
3, 6, 12 No NA
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
60
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
NA None
NA Name, ID no., room, age, sex, height, weight, operator, department, BP, requested by, user-defined 1, user-defined 2
NA Name, ID no., room, age, sex, height, weight, operator, department, BP, requested by, user-defined 1, user-defined 2
See Other Specifications Name, ID no., age, sex, height, weight, BP, race, Rx, Dx, operator, room, department, requested by, user-defined 1, user-defined 2
MEASUREMENTS
No No No
No No No
Analyzed waveform
NA
NA
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
2.5 LCD Not specified Not specified Lead off, low battery
2.5 LCD Not specified Not specified Loose contact, artifact, low battery
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
61
H x W x D, cm (in)
10.2 x 43.2 x 38.1 (4 x 17 x 15) 8.6 (19) Yes Lead acid Not specified 40 min Not specified
10.2 x 43.2 x 38.1 (4 x 17 x 15) 8.6 (19) Yes Lead acid Not specified 40 min Not specified
10.2 x 43.2 x 38.1 (4 x 17 x 15) 8.6 (19) Yes Lead acid Not specified 40 min Not specified
14 x 56.5 x 39.4 (5.5 x 22.3 x 15.5) 21.8 (48) Yes Lead acid Not specified 40 min Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Meets requirements of CSA, TUV, and UL.
Not specified Not specified Meets requirements of CSA, TUV, and UL.
Not specified Not specified Meets requirements of CSA, TUV, and UL; standard ACI and TPI.
Not specified Not specified Simultaneous 16-lead acquisition; remote start button; 3.5" disk drive storage; data can be stored at 500 Hz sample rate; acute cardiac ischemia predictive instrument; optional late potential SAECG and vectorcardiography Meets requirements of CSA, TUV, and UL.
62
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
100 110 Location onscreen Digital thermal array Yes 8.5 x 11", A4 Automatic Yes No 5, 10, 25, 50
Not specified 90 Yes Digital thermal array Yes 50 mm x 75 ft roll or 100 mm x 55 ft Yes Yes Yes 25, 50 (12-lead, time based)
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
6 Yes RS232
6 Yes RS232
Colons separate data on similar models of a device. * 10 automatic; 2.5, 5, 10, 15, 20, 25, 30, 40 manual.
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
63
Adult and pediatric resting ECG and 12lead ECG Not specified 2 full-capacity records, up to 100 single waveforms events & annotations Cascading ECG, trend summary report Name, ID no., age, sex, date
RIC
Not specified
Yes 12
Yes 12
Several thousand on PC card Name, ID no., age, sex, race, Sx, Hx, Dx, DRG, BP, Rx, reason for order, MD name, UPIN, order number, encounter ID, stat ECG, department, operator ID, room, weight, height, user defined HR, PR, QT, QTC, PQRST axis
No Yes
No No
MEASUREMENTS
Yes
Yes
No No Yes
Analyzed waveform
Yes
Yes
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 Complete printed ECG See footnote * Not specified Loose contact, artifact, low battery
10 No EL or LCD Not specified 12-lead too noisy, leads off, pacer on interpretation suppressed, progress messages, system status messages, data-transmission messages
Colons separate data on similar models of a device. * 15" diagonal color liquid crystal touchscreen.
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
64
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
H x W x D, cm (in)
45 x 45.8 x 16 (17.7 x 18 x 6.3) 14 (30.9) Yes Lithium-ion SMART 2/10.8 40 min Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
$7,995-17,995 1 year; 5 years in hospital Not specified Not specified Not specified
Not specified Not specified Optional magneticcard reader; optional bar-code reader; ECG snapshots can be shown as thumbnails in INDEX or full size in PREVIEW; 1 min full-size FD for 1 lead printout or 5 min half-size FD for 3 lead printouts.
Not specified Not specified Uses Marquette 12SL analysis program for pediatric and adult analysis; configurable to include AED and manual defibrillation; upgradable; data storage and retrieval; fax transmission; MUSE CV and LIFENET compatible; enhanced battery system; external pacing and SpO2 optional; ADAPTIV biphasic waveform technology; NIBP; EtCO2; 2 IBP lines; vital signs trending; ST-segment monitoring.
NA/not specified Not specified Parameter calculation; connects to SA2; 240 x 320 LCD, 3/6 channels.
Colons separate data on similar models of a device. * 5 removable and replaceable battery-type options: FASTPAK (Ni-Cd), FASTPAK 2 (Ni-Cd), LIFEPAK SLA (sealed lead acid), LIFEPAK 1.7 A-hr (Ni-Cd), or LIFEPAK 2.4 A-hr (Ni-Cd).
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
65
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
12.4 103 Yes Laser, dot matrix, ink jet No 8.5 x 11", A4 Yes No Yes 12.5, 25, 50
12.4 103 Yes Laser, dot matrix, ink jet No 8.5 x 11", A4 Yes No No 12.5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
3 Yes RS232
3 Yes RS232
12 Yes Modem
12 Yes Network
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
66
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Not specified
RIC
Resting ECG
Yes 12
Yes 12
No Unlimited
No Unlimited
None No
No Yes
MEASUREMENTS
Yes
Yes
No No Yes
Analyzed waveform
Yes
Yes
Not specified
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
67
H x W x D, cm (in)
13.3 x 8.3 x 1 (5.2 x 1.2 x 0.4) 0.27 (0.6) Yes AA 2/not specified 6 Not specified
9.1 x 8.5 x 2 (3.4 x 3.3 x 0.8) 0.28 (0.6) Optional Not specified Not specified Not specified Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
NA/not specified Not specified Parameter calculation; 240 x 320 LCD; 3 channels.
68
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
0.05-150 Notch, EMG, digital smoothing, baseline, myogram line >100 >100 Yes Digital thermal array Yes 8.3 x 5" Automatic Yes Yes 10, 25, 50
0.05-150 Notch, EMG, digital smoothing, baseline, myogram line >100 >100 Yes Digital thermal array Yes 8.3 x 8.3" Automatic Yes Yes 10, 25, 50
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
12.4 103 Yes Laser, dot matrix, ink jet No 8.5 x 11", A4 Yes No No 12.5, 25, 50
>100 100 Yes Digital thermal array External via PC 3.5", 8.5 x 11" via PC Automatic Yes Yes 10, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
12 Yes Network
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
69
Resting ECG
Adult and pediatric ECG, stress testing, BP Direct function keys Unlimited
Adult and pediatric ECG, stress testing, BP Direct function keys Unlimited
No Unlimited
Unlimited, via PC Name, ID no., age, sex, height, weight, BP, medication, comments, DOB, room no., referring physician
Unlimited Name, ID no., DOB, sex, race, height, weight, BP, date, time, medications, physician, location, comments
Unlimited Name, ID no., DOB, sex, race, height, weight, BP, date, time, medications, physician, location, comments
MEASUREMENTS
Analyzed waveform
Not specified
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 PC monitor, CRT Not specified 12, on PC monitor Reversed leads, muscle tremor, loose contact, baseline wander, system status, low battery, hookup test
10 Color TFT Not specified 12 Reversed leads, muscle tremor, loose contact, baseline wander, system status, low battery, hookup test
10 Color TFT Not specified 12 Reversed leads, muscle tremor, loose contact, baseline wander, system status, low battery, hookup test
Colons separate data on similar models of a device. * Summary graphs of BP, speed/elevation, HR, tabular final report, ST-trend graphs, average complex graphs, full-disclosure rhythm of entire stress test, user-customizable, CS-200 model also with VES and arrhythmias.
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
70
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Yes 110/130/220/240 VAC, 50/60 Hz 5 x 15 x 23 (2 x 6 x 9) 1.9 (4.2) Yes Ni-Cd 1/7.2 2.5 4
H x W x D, cm (in)
9.1 x 8.5 x 2 (3.4 x 3.3 x 0.8) 0.28 (0.6) Optional Not specified Not specified Not specified Not specified
100 x 350 x 285 (39.4 x 137.8 x 112) 6.8 (15) Yes Lithium 1/12 30 min 2
130 x 432 x 332 (51.2 x 170 x 130.7) 12.7 (28) Yes Lead acid 1/12 50 min 2
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified/>2,150 January to December PC-ECG; can also be conventional 3channel ECG recorder; standard resting ECG with interpretation for adults and peds; QT dispersion; data management exercise ECG; signal averaging; HR variability; pacemaker analysis; integrated data management program SEMA. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified January to December PC-based system with Windows NT; 128 MB RAM; 5 RS232 interfaces; parallel interface; Ethernet; integrated to HIS over exp/imp. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified January to December PC-based system with Windows NT; 128 MB RAM; 5 RS232 interfaces; parallel interface; Ethernet; integrated to HIS over exp/imp. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
71
0-150 Notch, EMG, baseline and smoothing filters >100 100 Yes Digital thermal array Yes A4, 8.5" x 11" Automatic Yes No 5, 25, 50
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>100 90 Yes Digital thermal array Yes 90 mm, 3.5" wide Automatic Yes No 5, 25, 50
>100 100 Yes Digital thermal array Yes A4, 8.5" x 11" Automatic Yes No 5, 10, 25, 50
100 >100 Yes Digital thermal array Yes 90 x 90 mm, 3.5" width Automatic Yes No 5, 10, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
3 No NA
6, 12 Yes RS232
3 Yes RS232
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
72
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
No None
No None
Yes Optional, up to 40
No 40
NA Name, age, sex, user ID, height, weight, BP, medication, comments, recording conditions (date, time, filter)
NA Name, ID no., age, sex, height, weight, BP, medication, comments, date, time
MEASUREMENTS
Analyzed waveform
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 No No NA Lead group, loose electrodes, battery operation, low battery, power, paper, filter status
10 No No NA Lead group, loose electrodes, battery operation, low battery, power, paper, filter status
10 LCD,14x12",120x90 mm Not specified 3 Lead group, loose electrodes, battery status, date, time, power, paper, filter status, source
10 LCD, 125 x 90 mm Not specified 12 via PC Muscle tremor, loose contact, baseline wander, system status, low battery, hookup test
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
73
Yes 110-115/220-240 VAC, 50/60 Hz 6.9 x 29 x 21 (2.7 x 11.4 x 8.3) 2.9 (6.5) Built-in charger Lead acid 1/12 2 4
Yes 110-115/220-240 VAC, 50/60 Hz 10.1 x 40 x 33 (4 x 15.7 x 13) 4.8 (10.6) Built-in charger Lead acid 1/12 5 6
Yes 100-115/220-240 VAC, 50/60 Hz 10.2 x 40 x 33 (4 x 15.7 x 13) 5 (11) Built-in charger Lead acid 2/12 4 6
H x W x D, cm (in)
5 x 23 x 15 (2.0 x 9.1 x 5.9) 1.9 (4.3) Built-in charger Lead acid 1/9.6 1.5 2.5
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not spec/>40,000 January to December Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified/>6,000 January to December Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified/>9,700 January to December Spirometry; automatic ECG measurements and interpretation; data transmission and archiving on a PC. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified/>4,200 January to December Telemedicine optional. Meets requirements of AAMI, AHA, CSA, Homologation, IEC 601-1, ISO 9001, UL, and VDE.
74
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
>100 100 Yes Digital thermal array Yes, & laser via PC 210 mm width (8.5" x 5.5") Automatic No No 2.5, 5, 10, 12.5, 25, 50, 100
>100 100 Yes Digital thermal array Parallel port A4, 8.5 x 11" with parallel port Automatic Yes No 5, 25, 51
>100 100 Yes Digital thermal array Yes 8.5 x 11" Automatic Yes Yes 5, 10, 12.5, 25, 50
Not specified Not specified Not specified Thermal printer, laser jet Yes 210 x 150 mm thermal Not specified Not specified Not specified 1, 2, 5, 20, 25, 50, 100
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
12
3, 6, or 8 Yes RS232
12 Yes RS232
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
75
Adult and pediatric resting ECG; stress testing, BP, and spirometry options Yes Up to 45
Adult and pediatric resting ECG, stress testing, BP Yes Unlimited (hardware)
Resting ECG, stress testing, long-term ECG, BP, late potentials Not specified Not specified
NA Name, ID no., age, sex, height, weight, BP, medication, comments, DOB, room no., referring physician
None Name, ID no., DOB, age, sex, height, weight, BP, medication
Unlimited (hardware) Name, ID no., DOB, sex, race, height, weight, BP, date, time, medications, physician, location, comments
MEASUREMENTS
Not specified
Analyzed waveform
Signal averaging
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 LCD, 25.4 cm (10 in) Not specified 3, 6, 8 Reversed leads, muscle tremor, loose contact, baseline wander, system status, low battery, hookup test
10 LCD,14x12",120x90 mm Not specified 3 Lead group, loose electrodes, battery operation, low battery, power, paper, filter status
10 PC monitor, CRT Not specified 12 Reversed leads, muscle tremor, loose contact, baseline wander, system status, low battery, hookup test
Colons separate data on similar models of a device. * Summary graphs of BP, speed/elevation, HR, tabular final report, ST-trend graphs, average complex graphs, full-disclosure rhythm of entire stress test, user-customizable, CS-200 model also with VES and arrhythmias.
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
76
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
Yes 110/130/230/240 VAC, 50/60 Hz 7 x 32 x 21 (2.8 x 12.6 x 8.2) 4.7 (12) Yes Lead acid 2/12 1 4
Yes 110-115/220-240 VAC; 50/60 Hz 10.1 x 40 x 33 (4 x 15.7 x 13) 5 (11) Built-in charger Lead acid 1/12 4 6
H x W x D, cm (in)
153 x 62 x 60 (60.1 x 24.4 x 23.6) 71 (167.7) Yes Lead acid 2/12 3 min Not specified
9 x 34 x 35 (3.5 x 13.4 x 13.8) 4.3 (9.5) Yes Not specified Not specified Not specified Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not spec/>10,000 January to December Spirometer function; built-in stress test; rhythm report; laptop design; optional signaling averaging, R-R variability. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified/>240 January to December Spirometry; automatic ECG measurements and ECG interpretation; data transmission and archiving on a PC. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified/>1,900 January to December PC-based system with Windows 98 PC system; 128 MB RAM; 2 RS232 interfaces; parallel interface; QT dispersion; integrated to HIS over exp/imp; optional spirometry, 12channel FD, vector loop, late potential, ergo-spiro. Meets requirements of BSI, CSA, Homologation, IEC 601-1, ISO 9001, MET, UL 544, and VDE.
Not specified Not specified Network; database; visual indicators for connection with Cardos; complete data management for statistics, reimbursement.
Colons separate data on similar models of a device. * Price current as of October 2001.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
77
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
100 100 No Digital thermal array Yes 7 x 11" Yes Yes No 5, 10, 20
2 x 20 100 Yes Digital thermal array Not specified 110 mm x 18 m Automatic Yes Yes 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
12
12
3/6 No NA
3 No NA
3, 6 Yes RS232C
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
78
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
HES
Automatic/manual
Resting ECG; optional stress test and high-resolution ECG Yes 10,000/GB memory
Not specified
No 1
Not specified No
MEASUREMENTS
No
No
NA NA No
No No No
NA NA No
Analyzed waveform
Yes
NA
Not specified
NA
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 No VGA backlit 3 Power supply, low battery, loose contact, end paper, chart speed, sensitivity, filter
Not specified Yes Yes 12 Real-time display on PC monitor: 12 channel signals, grid, filters, recording status, HR, display speed and amplitude coefficient
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
79
Yes From USB port of PC, no battery needed 4 x 19 x 10 (1.6 x 7.5 x 4) without PC and cart 0.4 (0.9) without PC and cart Notebook PC Depends on notebook Depends on notebook Depends on notebook Depends on notebook
H x W x D, cm (in)
Not specified
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Backlit VGA display. Meets requirements of EN 60601-1, 1-2, 2-25, and 2-51.
Not specified Not specified ID no., date, and time; 1-touch operation. Meets requirements of IEC and JIS.
Not specified January to December PC-based Windows 98/ 00/XP; up to 1 hr recording, ECG data storage and full disclosure printout; 1,000 sps sampling rate.
NA/1,000 January to December Available in German, English, Russian; remote start-up input for various ergometers; 1 serial interface RS232C for data input from ergometer; 3 analog IV inputs.
80
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
WHERE MARKETED FDA CLEARANCE CE MARK (MDD) ADULT/PEDIATRIC/ NEONATE CONFIGURATION Cart LEADS Switching Sensitivity, mm/mV Calibration signal Frequency range, Hz Diagnostic Filtered
Input impedance, megohms CMRR @ 60 Hz, dB Leads-off indicator RECORDER Recording method
Not specified Not specified Not specified Digital thermal array Yes 210 x 60 mm (A4) Not specified Not specified Not specified 5, 25, 50
Integral printer Paper size Lead marker Timing marker Event marker Chart speed, mm/sec
12
3, 6, 12 Yes RS232C
This is the first of three pages covering the above model(s). These specifications continue onto the next two pages.
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
81
MICROPROCESSOR Programs
NA Age, sex : ID no., age, sex, height, medication, physician, comments, BP, pacemaker
MEASUREMENTS
Yes Yes Diagnosis, reason statements, measurements, stress-testing candidacy, graphical trends Average of 10 sec/ lead
Analyzed waveform
Analysis window, sec PREVIEW SCREEN DISPLAY No. of traces VISUAL INDICATORS
10 Not specified : LCD LED : LCD Not specified LED indicator, loose contact, noise, filter mode, low battery
This is the second of three pages covering the above model(s). These specifications continue onto the next page.
82
2003 ECRI. Duplication of this page by any means for any purpose is prohibited.
H x W x D, cm (in)
9.8 x 33.8 x 13.4 (3.9 x 13.3 x 5.3) 5.5 (12.1) : <6 (13.2) Yes Not specified Not specified Not specified 2
WEIGHT, kg (lb) BATTERY OPERATION Battery type No./voltage Operating time, hr Charging time, hr PLANNING & PURCHASE List price Warranty Delivery time, ARO Service contract Year first sold Number sold USA/worldwide Fiscal year OTHER SPECIFICATIONS
Not specified Not specified Variation/language in English, German, Russian, Czech, French. Meets requirements of DIN, IEC 601-1, TUV, and VDE 0750.