Professional Documents
Culture Documents
www.abb.com/motors&drives
> Motors
> Low voltage motors
> General purpose motors
Mechanical design .............................. 112
Ordering information ........................... 119
Technical data ...................................... 120
Variant codes ....................................... 128
Dimension drawings............................ 131
Rating plates ........................................ 140
Construction ........................................ 141
Cast iron motors in brief ..................... 142
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
111
Mechanical design
Stator
The motor frame including feet, bearing housing and
terminal box is made of cast iron. Integrally cast feet
allow a very rigid mounting and minimal vibration.
Drain holes
Motors, frame sizes 280 to 355, are fitted with drain
holes and closable plugs. The plugs are open on delivery. When mounting the motors, ensure that the drain
holes face downwards.
M000060
4
Terminal boxes are mounted on top of the motor as
standard. The terminal box can also be mounted on the
left or right side, see ordering information.
112
M000063
M000062
M000061
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Poles
Cable entry
mm
71M
2,4,6
2xM161.5
Motor
size
Poles
Cable entry
mm
160M
2,4,6,8
2xM401.5
2,4,6,8
2xM401.5
80M
2,4,6
2xM251.5
160L
90S
2,4,6
2xM251.5
180M
2,4,6,8
2xM401.5
90L
2,4,6
2xM251.5
180L
2,4,6,8
2xM401.5
100L
2,4,6,8
2xM321.5
200L
2,4,6,8
2xM501.5
112M
2,4,6,8
2xM321.5
225S
4,6,8
2xM501.5
132S
2,4,6,8
2xM321.5
225M
2,4,6,8
2xM501.5
132M
2,4,6,8
2xM321.5
250M
2,4,6,8
2xM631.5
Cast iron motor sizes 280 to 355 with top-mounted terminal box
Motor
size
Terminal
box
Flange
opening
Flange
Cable gland
Cable
entry
Cable
diameter
Auxiliary
entries
Terminal
bolt
C
D
E-D
2 x M63
2 x M63
2 x M63
2 x 32-49
3 x 32-49
3 x 32-49
2 x M20
2 x M20
2 x M20
M8
M10
M12
122/2
142/1
162/1
122/2
2 x M63
2 x 32-49
2 x M20
M8
142/1
162/1
D
E-D
2 x M63
2 x M63
3 x 32-49
3 x 32-49
2 x M20
2 x M20
M10
M12
122/2
2 x M63
2 x 32-49
2 x M20
M8
142/1
142/2
D
D
2 x M63
2 x M63
3 x 32-49
3 x 32-49
2 x M20
2 x M20
M10
M10
C
D
D
2 x M63
2 x M63
2 x M63
2 x 32-49
3 x 32-49
3 x 32-49
2 x M20
2 x M20
2 x M20
M8
M10
M10
280 SM_
315 SM_, ML_
355 S
122/2
142/1
142/2
Terminal box
Flange
3GZF294730-749 (280)
3GZF293703-753 (315-355)
Terminal box
Adapter E-D
3GZF294730-944
M000087
Flange
3GZF293703-753
(315-355)
Cable gland
3GZF294730-613
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Cable gland
3GZF294730-613
113
Terminal box
on top
on side
Opening
type
(D/Y-conn.)
Max. rated
current A
mm2
Max connection
cable area
Cable gland
diameter
Auxliary cable
entries
Cable box
diameter
Blank plate
280
315
355
122/2
142/1
142/2
162/1
C
D
D
E-D
363/210
640/370
640/370
950/550
2 x 150
2 x 240
2 x 240
4 x 240
2 x M40-63
1 x M40-63
2 x M40-63
2 x M20
2 x M20
2 x M20
max 2x60
max 2x60
max 2x80
max 4x60
MKLN 20
MKLN 30
M000088
NA
NA
Flange
Opening
C
D
E
E-D
Adapter 3GZF
294730-944
62
100
100
100
193
300
300
300
62
80
80
80
193
292
292
292
M8
M10
M10
M10
Bearings
The motors are normally fitted with single-row deep
groove ball bearings as listed in the table below.
Number
of poles
Motor
size
Number
of poles
71M
2-6
6202 VV C3
6202 VV C3
180M
2-8
6310 ZZ C3
6210 DDU C3
80M
2-6
6204 DDU C3
6204 DDU C3
180L
2-8
6310 ZZ C3
6210 DDU C3
90S
2-6
6205 DDU C3
6205 DDU C3
200L
2-8
6312 ZZ C3
6212 DDU C3
90L
2-6
6205 DDU C3
6205 DDU C3
225S
4-8
6313 ZZ C3
6213 ZZ C3
100L
2-8
6206 DDU C3
6206 DDU C3
225M
2-8
6313 ZZ C3
6213 ZZ C3
112M
2-8
6207 DDU C3
6206 DDU C3
250M
2-8
6314/C3
6214/C3
132S
2-8
6208 DDU C3
6207 DDU C3
280
6316/C4
6316/C4
132M
2-8
6208 DDU C3
6207 DDU C3
4-12
6316/C3
6316/C3
160M
2-8
6309 ZZ C3
6209 DDU C3
6316/C4
6316/C4
160L
2-8
6309 ZZ C3
6209 DDU C3
4-12
6319/C3
6316/C3
6316M/C3
6316M/C3
4-12
6322/C3
6319/C3
315
355
Axially-locked bearings
The D-end bearing is locked, in sizes 71 to 180 with
the spring ring and in sizes 200 to 355 with the inner
bearing cover. The inner ring is locked by tight tolerance to the shaft.
114
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Transport locking
Motors that have roller bearings or an angular contact
ball bearing are fitted with a transport lock before despatch to prevent damage to the bearings during transport. In case of transport locked bearing, motor sizes
280 to 355 are provided with a warning sign.
Bearing seals
The motors are as standard provided with seals according to table below.
Standard design
Alternative design
Axial seal
N-end
Number
of poles
d1
d2
B1
VS 80
VS 80
80x100x101)
80x100x10
2
4-12
80
80
100
100
13.5
13.5
10
10
VS 80
VS 95
VS 80
VS 80
80x100x101)
95x120x12
2
4-12
80
95
100
120
13.5
13.5
10
12
VS 95
VS 110
VS 95
VS 95
95x120x121)
110x140x121)
2
4-12
95
110
120
140
13.5
15.5
12
12
Motor
size
Description
D-end
71 to 132
160 to 225
250
280
VS 80
VS 80
315
355
1)
Viton-seal
M000089
Bearing life
The nominal life L10 of a bearing is defined according
to ISO as the number of operating hours achieved or
exceeded by 90% of identical bearings in a large test
series under certain specified conditions. 50% of the
bearings achieve at least five times this figure.
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
115
Lubrication
On delivery, the motors are lubricated with a type of
grease intended for use in dry or humid environments,
at normal ambient temperature.
Motors 250 to 355 have grease value lubrication for lubrication in service. The lubrication intervals and quantity
are stated in the maintenance manual which comes with
the motor.
Pulley diameter
When the desired bearing life has been determined,
the minimum permissible pulley diameter can be calculated with FR (or FRX), according to the formula:
D=
1.9 107 K P
N FR
Where:
D
= diameter of pulley, mm
P
= power requirement, kW
N
= motor speed, r /min
K
= belt tension factor, dependent on belt type and
type of duty. A common value for V belts is K=
2.5
FR = permissible radial force
Motor
Length of
shaft
extension
Radial forces
Ball bearings
20,000 hours
40,000
size
Poles
E (mm)
FX0 (N)
FXmax (N)
FX0 (N)
FXmax (N)
71 M
2
4
6
2
4
6
8
2
4
6
8
30
30
30
40
40
40
40
40
40
40
40
381
480
555
624
788
907
997
686
870
1000
1095
322
405
469
509
643
740
813
542
687
790
866
303
381
441
495
626
720
791
545
690
794
870
256
322
372
404
511
587
646
430
545
627
687
80 M
90 S
116
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Length of
shaft
extension
Radial forces
Ball bearings
20,000 hours
size
Poles
E (mm)
FX0 (N)
90 L
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
4
6
8
2
4
6
8
2
4
6
8
2
4
4
6
8
2
4
6
8
4
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
50
50
50
50
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
110
110
110
110
140
140
140
140
140
140
140
140
140
170
170
170
140
140
140
140
140
210
210
210
696
885
1015
1112
979
1234
1419
1566
1258
1592
1831
2020
1435
1821
2079
2299
1840
2107
2329
1544
1948
2232
2465
1563
1971
2259
2495
2984
3759
3802
4352
4800
4090
5162
5909
6518
5763
7261
4591
5791
6644
7296
5112
6440
7388
8113
7300
9200
10600
11600
7300
11300
13000
14300
7300
11300
13000
14300
9000
15200
17300
19000
100 L
112 M
132 S
132 M
160 M
160L
180M
180L
200L
225S
225M
250M
280SM_
315SM_
315ML
355 S_
40,000
FXmax (N)
564
717
823
901
785
989
1137
1255
1014
1284
1477
1629
1122
1423
1625
1797
1476
1690
1869
1200
1513
1734
1916
1243
1568
1797
1984
2371
2988
3073
3518
3881
3377
4262
4879
5382
4526
5703
3811
4594
5271
5788
4170
5254
6027
6619
6200
7800
8900
9800
6000
9400
10600
10400
6000
9400
10600
10400
7900
12500
14200
15600
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
FX0 (N)
553
702
806
883
777
979
1126
1243
998
1264
1453
1603
1139
1445
1650
1825
1461
1672
1849
1226
1546
1772
1957
1240
1565
1793
1980
2368
2984
3017
3454
3810
3246
4097
4690
5173
4574
5763
3644
4596
5273
5791
4057
5111
5864
6439
5800
7300
8400
9200
5800
9000
10300
11300
5800
9000
10300
11300
6200
12000
13700
15200
FXmax (N)
448
569
653
715
622
785
903
996
805
1019
1172
1293
890
1130
1290
1427
1172
1341
1483
952
1201
1377
1520
987
1244
1426
1575
1882
2371
2439
2792
3080
2680
3383
3872
4272
4593
4526
3025
3646
4184
4594
3310
4170
4784
5253
4900
6200
7100
7800
4950
7500
8500
9400
4950
7500
8500
9400
5300
9850
11300
12400
117
Motor
size
20,000 hours
2-pole
FAD
FAZ
N
N
4-pole
FAD
FAZ
N
N
6-pole
FAD
FAZ
N
N
71
80
90
270
430
470
270
430
470
360
590
650
360
590
650
440
710
780
440
710
780
800
870
100
112
132 S_
132 M_
650
840
950
-
650
840
950
-
880
880
1160 1160
1300 1300
1300 1300
1060
1380
1540
1540
1060
1380
1540
1540
1020
1970
2570
2870
3220
1020
1970
2570
2870
3220
1380
2660
2660
3490
3900
3900
4380
1650
3200
4200
4720
5290
1650
3200
4200
4720
5290
280
315
355
7300 5300
7000 5000
10500 3500
1380
2660
2660
3490
3900
3900
4380
8000 6000
9000 7000
13500 6500
9000 7000
10600 8600
15300 8300
FAZ
FAD
Mounting arrangement IM V1
40,000 hours
2-pole
FAD
FAZ
N
N
FAD
N
800
870
200
320
350
200
320
350
270
440
470
270
440
470
1200
1570
1760
1760
1200
1570
1760
1760
480
620
690
-
480
620
690
-
650
850
960
950
650
850
960
950
1880
3620
4750
5310
5310
5960
1880
3620
4750
5310
5310
5960
740
1440
1890
2120
2380
740
1440
1890
2120
2380
1020
1970
1970
2580
2880
2880
3220
1020
1970
1970
2580
2880
2880
3220
8-pole
FAD
FAZ
N
N
10000 8000
11600 9600
16800 9800
5750 3750
5600 3600
8750 1750
4-pole
FAZ
N
6200 4200
6900 4900
10800 3800
FAD
N
6-pole
FAZ
N
320
530
580
320
530
580
FAD
N
8-pole
FAZ
N
600
650
600
650
780 780
1020 1020
1140 1140
1140 1140
890 890
1170 1170
1310 1310
1310 1310
1210
2350
3080
3460
3880
1390
2670
3500
3900
3900
4380
1210
2350
3080
3460
3880
1390
2670
3500
3900
3900
4380
6900 4900
7900 5900
12000 5000
7700 5700
8900 6900
13300 6300
6-pole
FAD
FAZ
N
N
8-pole
FAD
FAZ
N
N
M000023
160
180M
180L
200
225S
225M
250
FAZ
M000022
Motor
size
20,000 hours
2-pole
FAD
FAZ
N
N
4-pole
FAD
FAZ
N
N
6-pole
FAD
FAZ
N
N
8-pole
FAD
FAZ
N
N
71
80
90
280
450
500
260
410
440
380
620
590
450
740
820
420
560
730
830
920
770
830
210
340
380
190
300
320
280
460
510
250
410
440
340
550
620
310
500
530
100
112
132 S_
132 M_
710
920
1050
-
590
770
830
-
950
800
1260 1050
1450 1160
1480 1120
1140 980
1490 1270
1690 1400
1730 1320
1280
1680
1930
1950
1110
1470
1600
1580
530
690
800
-
420
540
570
-
720
950
1100
1130
560
740
810
770
860
1130
1280
1320
700
910
990
910
160 M_
160 L_
180 M_
180 L_
200
225 S_
225 M_
250
1240
1320
2320
3050
3570
4090
750
710
1630
2050
2180
2360
1670
1730
3100
3170
4100
4680
4770
5570
1100
1030
2230
2150
2880
3130
3040
3180
1960
2050
3750
4830
5650
6520
1340
1250
2650
3510
3790
4070
2140
2260
4160
5450
6120
6250
7210
1560
1500
3100
4060
4500
4370
4700
970
1050
1780
2370
2810
3240
480
440
1100
1370
1420
1520
1300
1370
2400
2480
3180
3650
3740
4420
730
670
1540
1460
1970
2100
2020
2030
1530
1610
2900
3700
4390
5100
900
820
1800
2390
2530
2650
1650
1770
3200
4200
4720
4850
5630
1070
1010
2140
2800
3090
2960
3120
8500 4300
9000 3700
9600 3400
1)
10000
9500
11600
12400
18500
4600
5400
5000
3800
11000
13500
14800
21200
5500
6200
5600
5000
12200
14500
16200
23000
6600
7500
7000
6800
6950 2700
7450 2100
8100 1850
1)
12200
7700
9450
10100
15700
2800
3200
2850
1000
8900
10900
12200
18000
3350
3650
3150
1750
9750
11900
13200
19400
4200
4650
4150
3100
280
315 SM_
315 ML_
355 S_
1)
350
560
600
40,000 hours
2-pole
4-pole
FAD
FAZ
FAD
FAZ
N
N
N
N
620
690
560
600
970 800
1270 1060
1470 1140
1490 1120
On request
118
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Ordering information
When placing an order, please state the following
minimum data in the order, as in the example.
Motor type
M2QA 90S4A
Pole number
4
Mounting arrangement (IM-code) IM B3 (IM 1001)
Rated output
1.1 kW
Product code
3GQA092101-ADA
Variant codes if needed
D, E, F
5-6 7
8-10 11 12 13 14
A Motor type
B Motor size
C Product code
D Mounting arrangement code
E Voltage and frequency code
F Generation code
G Variant codes
112
132
160
180
20
22
25
28
=
=
=
=
200
225
250
280
Position 12
Mounting arrangement
A = Foot-mounted, top-mounted terminal box
R = Foot-mounted, terminal box on RHS,
seen from D-end
L = Foot-mounted, terminal box on LHS,
seen from D-end
B = Flange-mounted, large flange
C = Flange-mounted, small flange sizes (71-112)
H = Foot- and flange-mounted
31 = 315
35 = 355
Position 13
Voltage and frequency code
See tables on appropriate page
6
7
8
9
=
=
=
=
12 poles
>12 poles
Two-speed motors
Multi-speed motors
Position 14
Generation code
A, B, C
The product code must be, if needed, followed by
variant codes.
Positions 8 to 10
Serial number
Position 11
- (dash)
size
50Hz
60 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
71-250
220-240 V
380-420 VY
220, 230 V
380,400,415VY
440-480 VY
440VY
380-420 V
660-690 VY
380, 400, 415 V
660, 690 VY
440-480V1)
440V
-
415 V
415 V
-
500 V
500 V
-
575 V
-
500 VY
500 VY
-
660 V
660 V
-
690 V
690 V
-
280-400
X
Other rated
voltage,
connection or
frequency,
690 V maximum
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
119
Motor type
Full
3/4
Speed load
load
r/min
100% 75%
Product code
0.37
0.55
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
2)
2)
2)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
71 M2A
71 M2B
80 M2A
80 M2B
90 S2A
90 S2A
90 L2A
100 L2A
112 M2A
132 S2A
132 S2B
160 M2A
160 M2B
160 L2A
180 M2A
200 L2A
200 L2B
225 M2A
250 M2A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
1)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
112 L2 A
132 M2A
132 M2B
160 L2B
180 L2A
200 L2C
225 M2B
250 M2B
280 SMC
Current
factor
cos
100%
IN
Is
TN
Ts
Tmax
IN
Nm
TN
TN
1.27
1.89
2.52
3.68
5.03
5.03
7.37
10.02
13.17
17.99
24.53
35.85
49.06
60
71
96
119
144
177
241
289
353
423
513
641
800
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.5
2.5
2.5
2.3
2.2
2.3
2.5
2.4
1.7
1.7
1.5
1.7
1.7
2.6
1.5
3.0
2.7
3.0
2.2
2.5
2.5
3.5
3.0
3.2
3.0
3.5
3.1
2.6
2.7
2.5
2.6
2.6
2.7
2.7
2.6
2.5
2.5
2.5
2.4
3.1
2.8
2.0
2.0
2.2
2.3
2.3
2.2
2.5
2.4
1.9
2.1
2.2
2.2
2.8
2.8
2.6
2.8
2.8
2.6
400 V 50 Hz
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
071 301-A
071 302-A
081 301-A
081 302-A
091 101-A
091 101-A
091 501-A
101 501-A
111 301-A
131 101-A
131 102-A
161 301-A
161 302-A
161 501-A
181 301-A
201 501-A
201 502-A
221 301-A
251 301-A
281 210-D
281 220-D
311 210-D
311 220-D
311 230-D
311 410-D
351 100-D
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
111 501-A
131 301-B
131 302-B
161 502-A
181 501-A
201 503-A
221 302-A
251 302-A
281 230-D
Power
2780
2785
2840
2855
2850
2850
2850
2860
2900
2920
2920
2930
2920
2930
2940
2955
2955
2970
2960
2974
2970
2979
2977
2976
2980
2983
70.0
73.0
75.0
78.0
79.0
79.0
81.5
83.0
85.0
87.5
88.5
90.0
90.0
90.5
90.8
91.4
92.2
92.6
93.4
94.1
94.5
94.1
94.7
95.1
95.7
95.7
Basic design
68.0
72.4
75.5
77.9
79.0
79.0
81.8
83.2
84.6
87.9
90.1
90.5
90.1
90.9
91.0
91.1
91.8
92.2
91.7
93.6
94.2
93.4
94.1
94.8
95.3
95.3
0.81
0.82
0.85
0.85
0.87
0.87
0.86
0.88
0.90
0.89
0.90
0.89
0.89
0.90
0.90
0.90
0.90
0.89
0.89
0.87
0.89
0.85
0.87
0.88
0.88
0.89
3)
0.90
0.88
0.90
0.90
0.90
0.90
0.89
0.89
0.90
400 V 50 Hz
1)
2)
3)
2900
2910
2900
2930
2950
2955
2975
2970
2973
82.0
85.5
88.0
88.0
90.8
92.0
92.6
91.0
95.0
Torque
0.94
1.33
1.7
2.4
3.15
3.15
4.53
5.93
7.55
10.2
13.6
19.82
27.03
32.78
38.86
52
64
78
96
134
156
198
232
273
345
424
6.1
6.1
6.1
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
6.5
6.5
6.5
6.5
6.5
6.5
7.0
7.5
6.7
6.4
6.3
6.3
6.2
7.9
6.8
High-output design
3)
3)
3)
3)
3)
3)
3)
94.8
10.76
17.65
20.05
40.09
53
78
96
134
187
7.0
7.5
8.0
6.5
6.5
7.0
7.0
7.0
6.7
18.1
30.2
36.2
71
97
145
177
241
353
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Output
kW
Motor type
Speed
r/min
Efficiency
%
380 V 50 Hz
0.37
0.55
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
2765
2780
2825
2840
2835
2835
2835
2845
2885
2905
2905
2918
2917
2920
2940
2950
2950
2965
2956
2970
2966
2976
2974
2972
2978
2981
2)
2)
2)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
71 M2A
71 M2B
80 M2A
80 M2B
90 S2A
90 S2A
90 L2A
100 L2A
112 M2A
132 S2A
132 S2B
160 M2A
160 M2B
160 L2A
180 M2A
200 L2A
200 L2B
225 M2A
250 M2A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
1)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
112 L2 A
132 M2A
132 M2B
160 L2B
180 L2A
200 L2C
225 M2B
250 M2B
280 SMC
70.0
73.0
75.5
77.5
79.0
79.0
81.5
83.0
85.0
87.5
87.5
90.0
90.0
90.5
90.8
91.2
91.7
92.2
93.2
94.0
94.2
94.1
94.5
95.0
95.6
95.7
Power
factor
cos
Current
Speed
IN
r/min
A
0.83
0.84
0.86
0.86
0.90
0.90
0.89
0.90
0.92
0.90
0.90
0.91
0.91
0.91
0.91
0.91
0.91
0.90
0.90
0.88
0.89
0.86
0.87
0.88
0.89
0.90
0.97
1.37
1.75
2.52
3.23
3.23
4.61
6.14
7.82
10.7
14.5
20.41
27.82
34.13
40.45
54
67
82
100
137
163
208
243
290
358
440
Efficiency
%
Power
factor
cos
Current
IN
A
0.79
0.79
0.85
0.83
0.86
0.86
0.83
0.86
0.87
0.88
0.90
0.87
0.88
0.89
0.88
0.89
0.89
0.87
0.88
0.86
0.88
0.83
0.85
0.88
0.87
0.88
0.93
1.33
1.64
2.37
3.08
3.08
4.56
5.85
7.53
9.94
13.1
19.54
26.35
31.95
38.3
51
62
77
93
130
151
197
230
265
335
412
415 V 50 Hz
380 V 50 Hz
2795
2800
2855
2870
2865
2865
2865
2875
2915
2935
2935
2930
2932
2935
2955
2960
2960
2975
2962
2976
2974
2980
2979
2978
2982
2984
70.0
73.0
75.0
78.0
79.0
79.0
81.0
83.5
85.0
88.0
89.0
90.0
90.0
90.5
90.8
91.3
92.3
92.6
93.5
94.2
94.6
94.1
94.7
95.2
95.7
95.7
Weight
kg
Sound
pressure
level LP
dB(A)
Basic design
415 V 50 Hz
0.0003
0.00037
0.00091
0.00107
0.00135
0.00135
0.00163
0.00402
0.00671
0.01241
0.01491
0.0436
0.0551
0.06549
0.08805
0.14821
0.16822
0.29345
0.3784
0.7
0.82
1.05
1.25
1.5
1.95
2.7
10
11
16
17
21
21
24
33
42
58
63
112
122
142
170
235
254
328
390
570
610
820
870
960
1130
1500
56
56
57
58
61
61
61
65
67
70
70
72
72
72
72
81
81
81
84
78
78
83
83
83
83
83
High-output design
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
2968
94.8
0.90
198
2975
95.1
0.89
180
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Moment
of inertia
J=1/4 GD2
kgm2
0.00826
0.01500
0.01768
0.06549
0.10339
0.18473
0.33431
0.45829
1.05
49
68
73
130
185
276
340
411
660
70
71
73
75
75
81
81
85
78
121
Output
kW
Motor type
Product code
Speed
r/min
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
2)
2)
2)
2)
2)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
71 M4A
71 M4B
80 M4A
80 M4B
90 S4A
90 L4A
100 L4A
100 L4B
112 M4A
132 S4A
132 M4A
160 M4A
160 L4A
180 M4A
180 L4A
200 L4A
225 S4A
225 M4A
250 M4A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
1)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
112 L4A
132 M4B
132 M4C
160 L4B
180 L4B
200 L4B
225 M4B
250 M4B
280 SMC
Power
Current
Full
load
100%
factor
cos
100%
IN
Is
TN
Ts
Tmax
IN
Nm
TN
TN
1.71
2.53
3.73
5.06
7.5
10.31
14.69
20.18
26.71
36.73
49.74
71
98
120
142
194
238
290
354
483
580
707
849
1028
1286
1604
2.1
2.1
2.4
2.4
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.4
2.3
2.3
2.4
2.2
2.2
2.2
2.4
2.1
2.1
1.7
1.9
2.1
2.1
2.0
2.7
2.7
2.7
2.6
2.4
2.6
2.7
2.8
2.8
2.9
2.7
2.8
2.4
3.0
3.0
2.9
2.7
2.7
2.7
2.6
2.4
2.3
2.4
2.6
2.5
2.6
2.2
2.2
2.2
2.2
2.2
2.2
2.3
2.3
2.7
2.2
2.2
2.2
2.4
2.6
2.6
2.4
2.4
2.8
3/4
load
75%
400 V 50 Hz
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
072 301-A
072 302-A
082 301-A
082 302-A
092 101-A
092 501-A
102 501-A
102 502-A
112 301-A
132 101-A
132 301-A
162 301-A
162 501-A
182 301-A
182 501-A
202 501-A
222 101-A
222 301-A
252 301-A
282 210-D
282 220-D
312 210-D
312 220-D
312 230-D
312 410-D
352 100-D
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
112 501-A
132 302-A
132 303-A
162 502-A
182 502-A
202 502-A
222 302-A
252 302-A
282 230-D
Efficiency
1395
1395
1410
1415
1400
1390
1430
1420
1430
1430
1440
1460
1460
1470
1470
1470
1480
1480
1480
1483
1481
1486
1485
1486
1485
1488
65.5
68.5
73.5
74.5
77.5
78.5
81.5
82.8
85.0
86.0
88.5
89.5
90.0
91.0
91.5
92.2
92.6
92.8
93.4
94.2
94.6
94.6
94.9
95.4
95.7
95.6
Basic design
63.3
69.4
71.4
75.2
77.8
79.2
82.3
82.5
84.6
87.1
88.3
90.0
90.4
90.9
90.0
91.8
91.2
91.7
91.3
94.2
94.7
94.2
94.7
95.2
95.6
95.3
0.72
0.75
0.72
0.75
0.78
0.79
0.81
0.83
0.82
0.85
0.85
0.85
0.86
0.86
0.88
0.88
0.85
0.87
0.87
0.83
0.86
0.84
0.85
0.85
0.86
0.85
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
95.1
0.83
0.85
0.85
0.86
0.88
0.88
0.87
0.87
0.85
400 V 50 Hz
1)
2)
3)
1430
1430
1430
1460
1470
1470
1480
1480
1484
84.0
84.0
84.5
87.0
89.0
89.2
91.0
90.4
95.1
Torque
0.77
1.04
1.5
1.93
2.65
3.5
4.85
6.3
8.29
10.9
14.4
20.87
27.97
34.12
39.44
53
67
80
98
138
162
203
239
286
354
448
5.2
5.2
5.2
6.0
6.0
6.0
6.0
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
7.0
7.0
7.0
6.3
6.4
6.4
6.1
6.7
6.4
6.7
High-output design
11.39
18.6
22.11
35.69
55
68
100
137
196
7.0
6.5
6.5
6.5
6.5
6.5
7.0
7.0
7.1
36.7
61
73
121
195
240
355
484
708
122
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Motor type
Output
kW
Speed
r/min
Efficiency
%
380 V 50 Hz
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
1385
1385
1400
1405
1390
1380
1420
1410
1420
1420
1430
1455
1452
1465
1465
1465
1475
1475
1477
1480
1478
1484
1483
1483
1482
1487
2)
2)
2)
2)
2)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
71 M4A
71 M4B
80 M4A
80 M4B
90 S4A
90 L4A
100 L4A
100 L4B
112 M4A
132 S4A
132 M4A
160 M4A
160 L4A
180 M4A
180 L4A
200 L4A
225 S4A
225 M4A
250 M4A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
1)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
66.0
69.0
73.5
74.5
77.0
78.5
81.5
82.5
84.5
85.5
88.0
89.5
90.0
91.0
91.5
92.3
92.3
92.6
93.2
94.0
94.2
94.5
94.8
95.0
95.2
95.6
Power
factor
cos
Current
Speed
IN
r/min
A
Power
factor
cos
Current
IN
A
415 V 50 Hz
0.74
0.78
0.75
0.78
0.80
0.80
0.82
0.85
0.84
0.87
0.85
0.87
0.88
0.88
0.90
0.89
0.85
0.88
0.88
0.85
0.86
0.85
0.86
0.86
0.86
0.86
0.78
1.05
1.52
1.97
2.72
3.64
4.98
6.5
8.57
11.3
15.2
21.46
28.78
35.1
40.59
55
71
83
102
143
169
209
248
300
375
465
1405
1405
1420
1425
1410
1400
1440
1430
1440
1440
1450
1463
1461
1470
1475
1470
1480
1480
1482
1484
1483
1487
1486
1487
1486
1489
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
64.0
68.0
72.5
74.0
77.5
78.5
81.4
82.7
85.0
86.5
88.0
89.5
90.0
91.0
91.5
92.2
92.0
92.8
93.6
94.2
94.7
94.6
95.0
95.4
95.7
95.6
0.79
1.07
1.55
1.96
2.65
3.48
4.85
6.17
8.24
10.7
14.1
20.6
27.28
34.49
38.9
55
68
79
95
137
157
198
232
279
343
438
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
94.8
0.86
204
1485
95.2
0.84
191
415 V 50 Hz
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Moment
of inertia
J=1/4 GD2
kgm2
Weight
kg
Sound
pressure
level LP
dB(A)
Basic design
0.69
0.71
0.68
0.72
0.75
0.77
0.78
0.82
0.80
0.83
0.84
0.83
0.85
0.82
0.86
0.88
0.82
0.85
0.86
0.82
0.85
0.82
0.84
0.84
0.85
0.84
380 V 50 Hz
112 L4A 3)
132 M4B 3)
132 M4C 3)
160 L4B 3)
180 L4B 3)
200 L4B 3)
225 M4B 3)
250 M4B 3)
280 SMC 1481
Efficiency
%
0.00053
0.00066
0.00145
0.00174
0.00254
0.00317
0.00679
0.00862
0.01306
0.02673
0.03432
0.06543
0.09349
0.16049
0.18046
0.2819
0.37
0.42
0.78
1.05
1.32
1.9
2.2
2.6
3.2
5.4
11
11
16
17
21
25
32
36
45
60
73
116
137
170
186
254
308
335
450
560
600
800
855
930
1030
1500
43
45
46
46
52
52
53
53
56
59
59
66
66
66
66
71
73
73
76
71
71
78
78
78
78
82
High-output design
0.01484
0.0347
0.04227
0.10686
0.20783
0.29715
0.6244
0.9125
1.7
49
75
80
147
200
277
351
485
660
64
71
73
66
70
72
75
77
71
123
Output
kW
Motor type
Product code
Speed
r/min
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
2)
2)
2)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
71 M6A
71 M6B
80 M6A
80 M6B
90 S6A
90 L6A
100 L6A
112 M6A
132 S6A
132 M6A
132 M6B
160 M6A
160 L6A
180 L6A
200 L6A
200 L6B
225 M6A
250 M6A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
112 M6B
132 M6C
160 L6B
180 L6B
200 L6C
225 M6B
250 M6B
280 SMC
Power
Current
Full
load
100%
factor
cos
100%
IN
Is
TN
Ts
Tmax
IN
Nm
TN
TN
1.8
1.8
1.9
1.9
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.3
2.2
2.1
2.2
2.3
2.4
2.4
1.9
1.9
2.1
2.2
1.8
2.4
2.5
2.0
1.8
2.3
2.6
2.4
2.3
2.4
2.9
3.0
2.3
2.4
2.9
2.5
3.2
2.9
2.6
2.4
2.4
2.3
2.3
2.6
2.5
2.3
3/4
load
75%
400 V 50 Hz
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
073 301-A
073 302-A
083 301-A
083 302-A
093 101-A
093 501-A
103 501-A
113 301-A
133 101-A
133 301-A
133 302-A
163 301-A
163 501-A
183 501-A
203 501-A
203 502-A
223 301-A
253 301-A
283 210-D
283 220-D
313 210-D
313 220-D
313 230-D
313 410-D
353 100-D
910
890
930
925
920
920
940
940
960
960
960
970
970
980
980
980
980
980
990
989
992
991
991
991
992
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
113 302-A
133 303-A
163 502-A
183 502-A
203 503-A
223 302-A
253 302-A
283 230-D
950
970
970
980
980
980
980
989
Efficiency
55.0
60.0
63.0
65.0
71.0
73.0
76.0
80.0
82.5
84.0
86.0
88.0
88.5
89.0
90.3
90.4
90.8
92.2
93.5
93.8
94.2
94.8
95.1
95.3
95.3
50.1
58.3
63.2
65.1
70.2
73.1
75.3
81.2
83.5
84.2
85.6
88.3
88.6
89.1
90.2
90.3
89.2
92.4
93.3
93.7
94.0
94.7
95.0
95.2
95.2
Basic design
0.65
0.65
0.66
0.68
0.72
0.74
0.77
0.76
0.78
0.77
0.79
0.78
0.78
0.82
0.82
0.83
0.78
0.88
0.82
0.83
0.80
0.83
0.82
0.83
0.83
0.73
0.93
1.29
1.8
2.12
2.94
3.78
5.23
6.73
8.93
11.7
15.77
23
29.67
36.06
42.32
61
66
85
103
145
166
206
242
293
0.76
0.78
0.78
0.82
0.78
0.78
0.88
0.83
740
14.49
30.3
37.87
63
78
82
139
400 V 50 Hz
1)
2)
3)
77.0
83.0
85.5
86.0
87.4
87.8
89.2
94.5
3)
3)
3)
3)
3)
3)
3)
94.5
Torque
4.0
4.0
5.0
5.0
5.0
5.0
5.5
5.5
6.5
6.5
6.5
6.0
6.0
6.0
6.0
6.0
6.6
6.8
6.7
6.4
6.3
6.5
6.7
6.5
6.2
1.89
2.68
3.8
5.68
7.79
11.42
15.24
22.35
29.84
39.79
54
73
108
146
180
214
292
360
434
531
722
867
1060
1272
1540
High-output design
6.5
6.5
6.0
6.0
6.0
6.6
6.8
6.9
30.2
64
138
180
292
361
439
724
1.9
1.9
2.1
2.2
2.0
2.1
2.2
2.6
2.1
2.1
2.2
2.7
2.6
2.6
2.6
2.5
124
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Output
kW
Motor type
Speed
r/min
2)
2)
2)
2)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
71 M6A
71 M6B
80 M6A
80 M6B
90 S6A
90 L6A
100 L6A
112 M6A
132 S6A
132 M6A
132 M6B
160 M6A
160 L6A
180 L6A
200 L6A
200 L6B
225 M6A
250 M6A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
Power
factor
cos
Current
Speed
IN
r/min
A
380 V 50 Hz
905
885
925
920
915
915
935
935
955
955
945
968
966
980
975
975
980
978
988
987
990
990
990
989
991
Efficiency
%
112 M6B 3)
132 M6C 3)
160 L6B 3)
180 L6B 3)
200 L6C 3)
225 M6B 3)
250 M6B 3)
280 SMC 987
55.5
60.0
63.5
65.0
71.0
73.0
76.0
79.0
82.0
84.0
85.5
88.0
88.5
89.0
90.6
90.9
90.5
92.0
93.9
93.5
94.1
95.7
94.9
95.1
95.2
0.69
0.65
0.70
0.71
0.75
0.77
0.79
0.77
0.81
0.77
0.80
0.79
0.80
0.84
0.84
0.84
0.78
0.90
0.83
0.84
0.82
0.84
0.83
0.83
0.83
Efficiency
%
Power
factor
cos
Current
IN
A
415 V 50 Hz
0.72
0.98
1.29
1.82
2.13
2.98
3.8
5.5
6.87
9.39
12.3
16.39
23.61
30.48
36.94
43.79
64
68
89
108
148
174
215
255
307
915
895
935
930
925
925
945
945
965
965
955
975
975
985
980
980
980
982
990
990
992
992
991
991
993
380 V 50 Hz
52.5
59.0
62.0
65.5
70.5
73.0
75.5
80.0
82.5
84.0
86.0
88.0
88.5
89.0
90.1
90.1
90.9
92.3
93.5
93.8
94.2
94.8
95.0
95.3
95.3
0.62
0.62
0.62
0.66
0.69
0.70
0.75
0.75
0.76
0.75
0.78
0.75
0.75
0.79
0.79
0.81
0.76
0.86
0.80
0.82
0.77
0.81
0.80
0.82
0.82
Weight
kg
Sound
pressure
level LP
dB(A)
Basic design
0.77
0.95
1.33
1.79
2.15
2.98
3.73
5.14
6.66
8.84
11.4
15.81
23.06
29.68
36.16
41.93
60
64
84
101
143
163
203
237
287
415 V 50 Hz
0.00056
0.00074
0.00159
0.00196
0.00292
0.00379
0.00999
0.03116
0.03116
0.04074
0.05332
0.09231
0.1297
0.2418
0.34174
0.46837
0.62691
0.97
1.6
1.9
2.8
3.6
4.4
5.3
7.3
10
11
17
18
21
25
32
40
55
65
75
119
140
180
231
254
308
382
540
580
780
870
930
1040
1500
42
42
45
45
48
48
51
54
56
56
56
61
62
63
64
64
66
68
71
71
75
75
75
75
77
High-output design
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
3)
94.3
0.84
144
990
94.6
0.82
135
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Moment
of inertia
J=1/4 GD2
kgm2
0.0199
0.0611
0.139
0.28398
0.495
0.80327
1.32
2.6
45
75
155
196
291
351
455
660
56
59
64
65
66
68
71
71
125
Output
kW
Motor type
Product code
Speed
r/min
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
80 M8A
80 M8B
90 S8A
90 L8A
100 L8A
100 L8B
112 M8A
132 S8A
132 M8A
160 M8A
160 M8B
160 L8A
180 L8A
200 L8A
225 S8A
225 M8A
250 M8A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
112 M8B
132 M8B
160 L8B
180 L8B
200 L8B
225 M8B
250 M8B
280 SMC
Power
Current
Full
load
100%
3/4
load
75%
factor
cos
100%
IN
Is
TN
Ts
Tmax
IN
Nm
TN
TN
50.1
53.3
62.1
63.3
70.1
70.3
75.4
81.8
81.4
84.0
85.6
85.8
87.0
89.4
89.1
88.2
90.1
93.3
93.8
94.0
94.4
94.7
95.0
94.9
0.60
0.60
0.60
0.60
0.64
0.65
0.68
0.70
0.75
0.73
0.74
0.74
0.77
0.76
0.75
0.75
0.79
0.78
0.78
0.81
0.82
0.82
0.83
0.81
0.85
1.11
1.42
2.07
2.42
3.45
4.27
5.6
7.13
9.42
12.55
16.91
23.51
32.009
39.56
46.78
60
74
90
104
141
167
203
247
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.1
2.1
2.1
2.0
2.3
2.1
2.2
2.3
1.8
1.9
1.6
1.7
1.8
1.8
1.3
1.9
1.9
1.9
2.0
2.2
2.4
2.4
2.5
2.2
2.6
2.8
2.5
2.8
2.8
2.7
2.7
2.4
3.0
3.2
2.7
2.7
2.7
2.7
2.3
2)
0.68
0.75
0.74
0.77
0.76
0.75
0.79
0.79
5.94
9.38
19.86
33.2
40.85
66
76
108
400 V 50 Hz
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
3GBA
084 301-A
084 302-A
094 101-A
094 501-A
104 501-A
104 502-A
114 301-A
134 101-A
134 301-A
164 301-A
164 302-A
164 501-A
184 501-A
204 501-A
224 101-A
224 301-A
254 301-A
284 210-D
284 220-D
314 210-D
314 220-D
314 230-D
314 410-D
354 100-D
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GQA
3GBA
114 302-A
134 302-A
164 502-A
184 502-A
204 502-A
224 302-A
254 302-A
284 230-D
Efficiency
700
700
700
700
700
700
700
710
710
720
720
720
730
730
740
740
740
741
741
742
741
741
740
743
51.0
54.5
62.5
63.5
70.0
71.5
75.0
81.0
81.0
84.0
85.5
86.5
87.7
89.0
90.0
90.5
91.3
93.5
94.0
94.1
94.5
94.8
95.0
95.0
Basic design
400 V 50 Hz
1)
2)
700
710
720
730
730
740
740
741
72.0
78.0
83.5
84.7
86.0
87.5
88.3
94.4
Torque
3.3
3.6
4.4
4.7
5.0
5.0
5.0
5.5
5.5
5.5
5.5
5.5
5.4
5.5
5.5
6.0
6.5
7.3
7.6
7.1
7.1
7.4
7.3
6.5
2.46
3.41
5.05
7.5
10.23
15.01
20.46
29.59
40.35
53
72
99
143
196
238
283
387
477
580
708
968
1161
1420
1697
High-output design
2)
2)
2)
2)
2)
2)
94.3
5.2
5.5
5.5
5.4
5.4
6.3
6.5
7.8
27.3
51
113
196
242
387
478
709
1.7
1.7
2.0
1.9
1.9
2.1
2.2
1.9
1.9
1.9
2.4
2.6
2.6
2.6
2.5
3.2
126
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Motor type
Output
kW
EffiSpeed ciency
r/min %
380 V 50 Hz
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
695
695
695
695
695
695
695
705
705
715
715
715
725
725
740
740
738
740
740
741
740
740
739
742
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
M2BAT
80 M8A
80 M8B
90 S8A
90 L8A
100 L8A
100 L8B
112 M8A
132 S8A
132 M8A
160 M8A
160 M8B
160 L8A
180 L8A
200 L8A
225 S8A
225 M8A
250 M8A
280 SMA
280 SMB
315 SMA
315 SMB
315 SMC
315 MLA
355 S
1)
1)
1)
1)
1)
1)
1)
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2QA
M2BAT
112 M8B
132 M8B
160 L8B
180 L8B
200 L8B
225 M8B
250 M8B
280 SMC
51.0
54.0
62.0
63.0
70.0
71.5
75.0
80.5
81.0
84.0
85.5
86.5
87.7
88.9
89.9
90.4
91.1
93.2
93.8
93.9
94.3
94.6
94.9
94.9
Power
factor
cos
Current
Speed
IN
r/min
A
Efficiency
%
Power
factor
cos
Current
IN
A
415 V 50 Hz
0.61
0.61
0.61
0.61
0.67
0.68
0.68
0.75
0.78
0.76
0.76
0.77
0.79
0.78
0.75
0.76
0.80
0.80
0.80
0.83
0.83
0.84
0.84
0.82
0.88
1.16
1.49
2.18
2.43
3.45
4.47
5.6
7.22
9.52
12.86
17.11
24.12
32.86
41.69
48.65
63
75
92
108
147
173
210
258
380 V 50 Hz
705
705
705
705
705
705
705
715
715
720
720
722
730
730
745
745
741
742
742
743
742
742
741
743
51.5
54.5
62.5
63.5
69.0
70.5
75.0
80.5
81.0
84.0
85.5
86.5
87.7
88.8
90.3
90.3
91.4
93.4
94.0
94.1
94.5
94.8
95.0
95.0
Weight
kg
Sound
pressure
level LP
dB(A)
Basic design
0.60
0.60
0.60
0.60
0.64
0.62
0.67
0.69
0.72
0.70
0.70
0.70
0.74
0.74
0.71
0.71
0.78
0.76
0.75
0.79
0.81
0.81
0.81
0.80
0.82
1.08
1.38
2.01
2.39
3.47
4.16
5.55
7.11
9.46
12.78
17.23
23.58
31.75
40.14
47.74
58
73
90
103
137
164
198
244
415 V 50 Hz
0.00111
0.00326
0.00541
0.00756
0.00971
0.01186
0.01559
0.03625
0.04141
0.0676
0.09524
0.12122
0.23645
0.37103
0.53287
0.65825
0.975
1.85
2.2
3.2
4.1
4.9
5.8
7.3
16
17
21
24
31
34
42
56
64
105
125
142
176
235
290
302
392
570
610
820
910
980
1100
1500
42
42
46
46
53
53
55
55
56
58
58
58
61
63
65
65
67
65
65
65
65
65
72
75
High-output design
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
740
94.2
0.81
110
742
94.4
0.77
106
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Moment
of inertia
J=1/4 GD2
kgm2
0.0199
0.04776
0.1312
0.28398
0.46854
0.80327
1.28
2.85
45
75
136
196
274
349
436
690
58
59
61
63
65
67
69
65
127
Variant
Motor size
719080
100
1)
112132
160180
200250
280355
Balancing
052
417
NA
424
NA
NA
NA
NA
037
NA
NA
NA
039
Cold resistant grease (-55... +100C). For frame sizes 160-225, only posM
sible when using regreasable bearings.
Heat resistant grease (-25... 150C). For frame sizes 160-225, only possible
M
when using regreasable bearings.
040
041
NA
NA
043
NA
NA
M/S
178
209
NA
425
785
Reinforced tropicalisation.
Cooling system
068
Metal fan.
183
NA
Dimension drawing
141
Drain holes
065
NA
NA
076
NA
Earthing bolt
067
Heating elements
450
451
Insulation systems
014
NA
405
NA
*)
128
=
=
Included as standard
On modification of a stocked motor, or on new
manufacture,the number per order may be limited.
P
R
NA
=
=
=
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Code
Variant
1)
Motor size
719080
100
112132
160180
200250
280355
Mounting arrangements
008
NA
NA
009
047
IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5).
NA
NA
066
NA
NA
078
NA
NA
NA
090
IM 2101 foot/flange mounted, DIN C-flange, from IM 1001, (B34 from B3).
NA
NA
NA
Painting
114
Protection
005
072
073
158
211
Weather protected, IP xx W.
NA
401
NA
NA
NA
403
095
135
138
NA
139
161
NA
122
123
125
321
322
323
325
127
*)
=
=
Included as standard
On modification of a stocked motor, or on new
manufacture,the number per order may be limited.
P
R
NA
=
=
=
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Code
Variant
Motor size
719080
100
1)
112132
160180
200250
280355
435
436
437
439
441
442
445
446
Terminal box
015
NA
017
NA
021
NA
180
NA
137
NA
157
NA
230
231
NA
400
NA
418
NA
NA
NA
467
Lower than standard terminal box and rubber extended cable, length 2 m
included.
NA
468
NA
469
NA
731
Testing
140
Test confirmation.
NA
145
146
Type test with report for motor from specific delivery batch.
148
760
762
NA
NA
NA
NA
NA
NA
NA
704
NA
NA
NA
*)
130
=
=
Included as standard
On modification of a stocked motor, or on new
manufacture,the number per order may be limited.
P
R
NA
=
=
=
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Sizes 71-132
Dimension drawings
Foot-mounted; IM B3 (IM 1001), IM B6 (IM 1011), IM B7 (IM 1061),
IM B8 (IM 1071), IM V5 (IM 1011), IM V6 (IM 1031)
M000090
4
Motor
size
Poles
AA
AB
AC
AD
EG
71M
2-6
112
30
145
145
120
90
110
45
14
80M
2-6
125
35
160
165
145
100
135
50
19
M5
30
12.5
M6
40
90S
2-6
140
35
175
180
150
100
140
56
24
16
M8
50
90L
2-6
140
35
175
180
150
125
165
56
19
24
M8
50
19
100L
2-6
160
40
200
205
175
140
180
112M
2-8
190
50
235
225
185
140
190
63
28
M10
60
22
70
28
M10
60
132S
2-8
216
55
270
265
205
140
22
205
89
38
M12
80
132M
2-8
216
55
270
265
205
28
178
240
89
38
M12
80
28
Motor
size
Poles
GD
HA
HD
HF
LD
71 M
2-6
11
80 M
2-6
15.5
71
10
200
255
100
80
12
225
170
10
285
116
90 S
2-6
20
90 L
2-6
20
90
12
240
185
10
310
128
90
12
240
185
10
335
100 L
2-6
128
24
100
14
275
245
12
380
112 M
2-6
144
24
112
15
290
265
12
380
144
132 S
132 M
2-6
10
33
132
18
335
300
12
465
169
2-6
10
33
132
18
335
300
12
505
169
Tolerances:
A, B, C +, - 0.8
D,DA
ISO m6
F, FA
ISO h9
H + 0, - 0.5
N ISO j6
BB
DB
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
131
Sizes 71-132
Dimension drawings
Flange-mounted; IM B5 (IM 3001), IM V1 IM 3001), IM V3 (IM 3031)
IM B14 (IM 3601), IM V18 (IM 3611), IM V19 (IM 3631)
M000091
4
IM B5 (IM3001), IM V1 (IM3011), IM V3 (IM3031)
Type
M2QA
Poles
AC
AD
DB
EG
GD
HE
71M
80M
2-6
2-8
145
165
120
145
14
19
M5
M6
30
40
12.5
16
5
6
90S
90L
2-8
2-8
180
180
150
150
24
24
M8
M8
50
50
19
19
100L
2-8
205
175
28
M10
60
22
LA
11
15.5
5
6
165
200
255
285
9
9
8
8
20
20
7
7
200
200
310
335
24
265
380
130
165
110
130
160
200
10
12
3.5
3.5
10
10
165
165
130
130
200
200
12
12
3.5
3.5
11
215
180
250
15
112M
2-8
225
185
28
M10
60
22
24
270
395
11
215
180
250
15
132S
132M
2-8
2-8
265
265
205
205
38
38
M12
M12
80
80
28
28
10
10
33
33
8
8
320
320
465
505
12
12
265
265
230
230
300
300
15
15
4
4
Flange HE
size
71M
2-6
80M
2-8
90S
2-8
90L
2-8
100L
2-8
112M
2-8
C105
C140
C120
C160
C140
C160
C140
C160
C160
C200
C160
C200
Tolerances:
D,DA
ISO m6
F, FA
ISO h9
N
ISO j6
132
145
145
165
165
185
185
185
185
255
255
265
265
P
105
140
120
160
140
160
140
160
160
200
160
200
85
115
100
130
115
130
115
130
130
165
130
165
70
95
80
110
95
110
95
110
110
130
110
130
M6
M8
M6
M8
M8
M8
M8
M8
M8
M10
M8
M10
2.5
3
3
3.5
3
3.5
3
3.5
3.5
3.5
3.5
3.5
Above table gives the main dimensions in mm.
For detailed drawings please see our web-pages
'www.abb.com/motors&drives' or contact us.
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Sizes 71-132
Dimension drawings
Foot- and flange-mounted; M B35 (IM 2001), IM V15 (IM 2011), IM V 36 (IM 2031)
M000092
4
Motor
size
Poles
AA
AB
AC
AD
BB
DB
EG
71M
80M
90S
90L
100L
112M
132S
132M
2-6
2-8
2-8
2-8
2-8
2-8
2-8
2-8
112
125
140
140
160
190
216
216
30
35
35
35
40
50
55
55
145
160
175
175
200
235
270
270
145
165
180
180
205
225
265
265
120
145
150
150
175
185
205
205
90
100
100
125
140
140
140
178
110
135
140
165
180
190
205
240
45
50
56
56
63
70
89
89
14
19
24
24
28
28
38
38
M5
M6
M8
M8
M10
M10
M12
M12
30
40
50
50
60
60
80
80
12.5
16
19
19
22
22
28
28
5
6
8
8
8
8
10
10
Motor
size
Poles
71M
80M
90S
90L
100L
112M
132S
132M
2-6
2-8
2-8
2-8
2-8
2-8
2-8
4-8
Tolerances:
A, B, C +- 0.8
D,DA
ISO m6
F, FA
ISO h9
GD
HA
HD
HF
11
15.5
20
20
24
24
33
33
5
6
7
7
7
7
8
8
71
80
90
90
100
112
132
132
10
12
12
12
14
15
18
18
200
225
240
240
275
290
335
335
170
185
185
245
265
300
300
7
10
10
10
12
12
12
12
LA
LD
255
285
310
335
380
395
465
505
9
9
10
10
11
11
12
12
100
116
128
128
138
144
169
169
130
165
165
165
215
215
265
265
110
130
130
130
180
180
230
230
160
200
200
200
250
250
300
300
10
12
12
12
15
15
15
15
3.5
3.5
3.5
3.5
4
4
4
4
H + 0, -0.5
N ISO j6
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
133
Sizes 160-250
Dimension drawings
Foot-mounted; IM B3 (IM 1001), IM B6 (IM 1051), IM B7 (IM 1061),
IM B8 (IM 1071), IM V5 (IM 1011), IM V6 (IM 1031)
M000093
Motor
size
Poles
AA
AB
AC
AD
BB
DB
EG
160 M
160 L
180 M
180 L
200 L
225 S
225 M
225 M
250 M
250 M
2-8
2-8
2-4
4-8
2-8
4-8
2
4-8
2
4-8
254
254
279
279
318
356
356
356
406
406
60
60
70
70
70
75
75
75
80
80
325
325
350
350
390
435
435
435
490
490
330
330
355
350
395
440
450
450
515
515
255
255
270
270
305
335
335
335
395
395
210
254
241
279
305
286
311
311
349
348
265
310
315
350
380
380
405
405
455
455
108
108
121
121
133
149
149
149
168
168
42
42
48
48
55
60
55
60
60
65
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
110
110
110
110
110
140
110
140
140
140
36
36
36
36
39
39
39
39
39
39
Motor
size
Poles
GD
HA
HD
HF
LD
160 M
160 L
180 M
180 L
200 L
225 S
225 M
225 M
250 M
250 M
2-8
2-8
2-4
4-8
2-8
4-8
2
4-8
2
4-8
12
12
14
14
16
18
16
18
18
18
47
47
42.5
42.5
49
53
49
53
53
58
8
8
9
9
10
11
10
11
11
11
160
160
180
180
200
225
225
225
250
250
22
22
22
22
25
28
28
28
30
30
415
415
450
450
510
560
560
560
645
645
380
380
420
420
470
520
520
520
580
580
15
15
15
15
19
19
19
19
24
24
600
645
670
710
770
820
815
840
930
930
250
250
270
270
285
340
310
340
360
360
Tolerances:
A, B, C +, - 0.8
D,DA
ISO k6 < 50 mm
ISO h9 > 50 mm
134
F, FA
H
ISO h0
+ 0, - 0.5
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Sizes 160-250
Dimension drawings
M000094
4
Motor
size
Poles
AD
DB
EG
GD
HE
LA
160 M
160 L
180 M
180 L
200 L
225 S
225 M
2-8
2-8
2-4
4-8
2-8
4-8
2
255
255
270
270
305
335
335
42
42
48
48
55
60
55
M16
M16
M16
M16
M20
M20
M20
110
110
110
110
110
140
110
36
36
36
36
39
39
39
12
12
14
14
16
18
16
47
47
42.5
42.5
49
53
49
8
8
9
9
10
11
10
400
400
420
420
470
520
520
600
645
670
710
770
820
815
15
15
18
18
20
20
20
300
300
300
300
350
400
400
250
250
250
250
300
350
350
350
350
350
350
400
450
450
19
19
19
19
19
19
19
5
5
5
5
5
5
5
225 M
250 M
250 M
4-8
2
4-8
335
395
395
60
60
65
M20
M20
M20
140
140
140
39
39
39
18
18
18
53
53
53
11
11
11
520
655
655
840
930
930
20
22
22
400
500
500
350
450
450
450
550
550
19
19
19
5
5
5
Tolerances:
D,DA
ISO k6 < 50 mm
ISO m6 > 50 mm
F, FA
ISO h9
N
ISO j6
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
135
Sizes 160-250
Dimension drawings
Foot- and flange-mounted; IM B35 (IM 2001), IM V15 (IM 2011), IM V36 (IM 2031)
M000095
Motor
size
Poles
AA
AB
AC
AD
BB
DB
EG
160 M
160 L
180 M
180 L
200 L
225 S
225 M
225 M
250 M
250 M
2-8
2-8
2-4
4-8
2-8
4-8
2
4-8
2
4-8
254
254
279
279
318
356
356
356
406
406
60
60
70
70
70
75
75
75
80
80
325
325
350
350
390
435
435
435
490
490
330
330
355
350
395
440
450
450
515
515
255
255
270
270
305
335
335
335
395
395
210
254
241
279
305
286
311
311
349
349
265
310
315
350
380
380
405
405
455
455
108
108
121
121
133
149
149
149
168
168
42
42
48
48
55
60
55
60
60
65
M16
M16
M16
M16
M20
M20
M20
M20
M20
M20
110
110
110
110
110
140
110
140
140
140
36
36
36
36
39
39
39
39
39
39
12
12
14
14
16
18
18
18
18
18
47
47
42.5
42.5
49
53
49
53
53
53
Motor
size
Poles
GD
HA
HD
HF
LA
LD
160 M
160 L
180 M
180 L
200 L
225 S
225 M
225 M
250 M
250 M
2-8
2-8
2-4
4-8
2-8
4-8
2
4-8
2
4-8
8
8
9
9
10
11
10
11
11
11
160
160
180
180
200
225
225
225
250
250
22
22
22
22
25
28
28
28
30
30
415
415
450
450
510
560
560
560
645
645
380
380
420
420
470
520
520
520
580
580
15
15
15
15
19
19
19
19
24
24
600
645
670
710
770
820
815
840
930
930
15
15
18
18
20
20
20
20
22
22
250
250
270
270
285
340
310
340
360
360
300
300
300
300
350
400
400
400
500
500
250
250
250
250
300
350
350
350
450
450
350
350
350
350
400
450
450
450
550
550
19
19
19
19
19
19
19
19
19
19
5
5
5
5
5
5
5
5
5
5
Tolerances:
A, B, C +, - 0.8
D,DA
ISO k6 > 50 mm
ISO m6 > 50 mm
136
F, FA
H
N
ISO h9
+ 0, - 0.5
ISO j6
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Sizes 280-355
Dimension drawings
M000096
4
Motor
size
Poles A
AA
AB
AC
B'
BA
BB
CA
CA '
DA
DB
DC
EA
EG
EH
280 SM_ 2
4-12
457 85
457 85
530
530
572
572
368
368
419
419
146 506
146 506
190
190
400
400
349
349
65
75
60
65
M20
M20
M20
M20
140
140
140
140
40
40
40
40
315 SM_ 2
4-12
508 100
508 100
590
590
645
645
406
406
457
457
163 556
163 556
216
216
465
465
414
414
65
80
60
75
M20
M20
M20
M20
140
170
140
140
40
40
40
40
315 ML_ 2
4-12
508 100
508 100
590
590
645
645
457
457
508
508
163 607
163 607
216
216
465
465
414
414
65
90
60
75
M20
M24
M20
M20
140
170
140
140
40
48
40
40
355 _
2
4-12
610 120
610 120
700
700
740
740
500
500
161 662
161 662
254
254
460
460
70
100
70
90
M20
M24
M20
M24
140
210
140
170
40
48
40
48
Motor
size
Poles F
GA
GB
GC
GD
HA
HC
HD
LA
LC
LD
FA
GF
O
1)
280 SM_ 2
4-12
18
20
18
18
58
69
53
67.5 79.5 58
315 SM_ 2
4-12
18
22
18
20
58
71
315 ML_ 2
4-12
18
25
18
20
58
84
355 S_
20
28
20
25
2
4-12
Tolerances:
D, DA ISO M6
H
+ 0, - 1.0
11
12
11
11
280
280
40
40
566
566
745
745
24
24
1088
1088
22
22
1238
1238
332
332
100
100
69
85
53
64
11
67.5 79.5 14
11
12
315
315
50
50
638
638
840
840
30
30
1218
1248
25
25
1367
1397
351
381
115
115
69
95
53
64
11
67.5 79.5 14
11
12
315
315
50
50
638
638
840
840
30
30
1269
1299
25
25
1418
1448
351
381
115
115
12
14
355
355
55
55
725
725
955
955
35
35
1344
1414
25
25
1494
1594
397
467
130
130
1)
2)
64
69
Cooling distance.
Second shaft end on request.
Above table gives the main dimensions in mm.
For detailed drawings please see our web-pages
'www.abb.com/motors&drives' or contact us.
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
137
Sizes 280-355
Dimension drawings
M000097
4
Motor
size
Poles
AC
DA
DB
DC
EA
EG
EH
FA
GA
GB
GC
GD
GF
280 SM_
2
4-12
572
572
65
75
60
65
M20
M20
M20
M20
140
140
140
140
40
40
40
40
18
20
18
18
58
67.5
69
79.5
53
58
64
69
11
12
11
11
315 SM_
2
4-12
645
645
65
80
60
75
M20
M20
M20
M20
140
170
140
140
40
40
40
40
18
22
18
20
58
71
69
85
53
67.5
64
79.5
11
14
11
12
315 ML_
2
4-12
645
645
65
90
60
75
M20
M24
M20
M20
140
170
140
140
40
48
40
40
18
25
18
20
58
81
69
95
53
67.5
64
79.5
11
14
11
12
355 S_
2
4-12
746
645
70
100
70
90
M20
M24
M20
M24
140
210
140
170
40
48
40
48
20
28
20
25
62.5
90
74.5
106
62.5
81
74.5
95
12
16
12
14
Motor
size
Poles
HB
LA
LB
LC
LD
280 SM_
2
4-12
465
465
1088
1088
22
22
938
938
1238
1238
332
332
500
500
450
450
100
100
550
550
18
18
5
5
315 SM_
2
4-12
525
525
1218
1248
25
25
1078
1078
1367
1397
351
381
600
600
550
550
115
115
660
660
23
23
6
6
315 ML_
2
4-12
525
525
1269
1299
25
25
1129
1199
1418
1448
351
381
600
600
550
550
115
115
660
660
23
23
6
6
355 S_
2
4-12
600
600
1344
1414
25
25
1204
1204
1494
1594
397
467
740
740
680
680
130
130
800
800
23
23
6
6
1)
Tolerances:
D, DA ISO M6
F
ISO h9
H
+ 0, - 1.0
N
ISO j6 (280)
ISO js6 (315)
1)
2)
Cooling distance.
Second shaft end on request.
Above table gives the main dimensions in mm.
For detailed drawings please see our web-pages
'www.abb.com/motors&drives' or contact us.
138
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Sizes 280-355
Dimension drawings
M000098
Foot- and flange-mounted; M B35 (IM 2001), IM V15 (IM 2011), IM V 36 (IM 2031)
4
Motor
size
Poles A
AA
AB
AC B
B'
BA
BB
CA
CA ' D
DA
DB
DC
EA
EG
EH
FA
280 SM_ 2
4-12
457 85
457 85
400
400
349 65
349 75
60
65
M20
M20
M20 140
M20 140
140
140
40
40
40
40
18
20
18
18
315 SM_ 2
4-12
508 100
508 100
465
465
414 65
414 80
60
75
M20
M20
M20 140
M20 170
140
140
40
40
40
40
18
22
18
20
315 ML_ 2
4-12
508 100
508 100
465
465
414 65
414 90
60
75
M20
M24
M20 140
M20 170
140
140
40
48
40
40
18
25
18
20
355 _
2
4-12
610 120
610 120
460
460
70
100
70
90
M20
M24
M20 140
M24 210
140
170
40
48
40
48
20
28
20
25
Motor
size
Poles G
GB
HD
LA
LC
LD
GA
GC
GD GF
HA
HC
O
1)
280 SM_ 2
4-12
58 69
53
67.5 79.5 58
315 SM_ 2
4-12
58
71
315 ML_ 2
4-12
58
84
355 S_
2
4-12
11 11
12 11
280 40
280 40
566
566
745
745
24
24
1088 22
1088 22
1238 332
1238 332
500
500
450
450
550
550
18
18
5
5
100
100
69
85
53 64 11 11
67.5 79.5 14 12
315 50
315 50
638
638
840
840
30
30
1218 25
1248 25
1367 351
1397 381
600
600
550
550
660
660
23
23
6
6
115
115
69
95
53 64 11 11
67.5 79.5 14 12
315 50
315 50
638
638
840
840
30
30
1269 25
1299 25
1418 351
1448 381
600
600
550
550
660
660
23
23
6
6
115
115
355 55
355 55
725
725
955
955
35
35
1344 25
1414 25
1494 397
1594 467
645
715
740
740
680
680
23
23
6
6
130
130
Tolerances:
D, DA ISO M6
F
ISO h9
H
+ 0, - 1.0
N
ISO j6 (280)
ISO js6 (315)
64
69
1)
2)
Cooling distance.
Second shaft end on request.
Above table gives the main dimensions in mm.
For detailed drawings please see our web-pages
'www.abb.com/motors&drives' or contact us.
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
139
Rating plates
For motor sizes 71 to 132 the rating plate gives one
current value for the voltage area. That is the highest
current that can occur within the voltage area with the
given output.
M000100
M000101
140
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Motor construction
13
12
11
10
4
M000098
9
8
7
1
2
3
4
5
6
7
Endshield, D-end
Terminal box
Rating plate
Rotor
Fan
Fan cover
Terminal box cover
8
9
10
11
12
13
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Stator
Bolt
Bearing
Wave-shape spring ring
Endshield, N-end
Screw
141
71
90
100
112
132
160
Material
Paint thickness
Bearing end
Material
shields
Paint thickness
D-end
6202
DDU C3
6204
DDU C3
6205
DDU C3
6206
DDU C3
6207
DDU C3
6208
DDUC3
6309
ZZ C3
N-end
6202
DDU C3
6204
DDU C3
6205
DDU C3
6206
DDU C3
6206
DDU C3
6207
DDU C3
6209
ZZ C3
Bearings
Axially-locked
bearings
Lubrication
80
Rating plate
Material
Stainless steel
Terminal box
Frame material
Cover material
Cable entries
Terminals
Fan
Material
Fan cover
Material
Steel
Paint thickness
Material
Insulation
Copper
Insulation class F
Winding protection
On request
Material
Connections
Stator winding
Rotor winding
Balancing method
Key ways
Enclosure
IP 55
Cooling method
IC 411
142
2xM40x1.5
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
Bearings
Axially-locked
bearings
180
Terminal box
225
250
280
315
Paint thickness
Material
Paint thickness
D-end 2 pole
4 to 8 pole
6310
ZZ C3
6312
ZZU C3
6313
ZZ C3
6314 C3
6316/C4
6316/C3
6316/C4
6319/C3
6319M/C3
6322/C3
N-end 2 pole
4 to 8 pole
6210
ZZ C3
6212
ZZ C3
6213
ZZ C3
6214 C3
6316/C4
6316/C3
6316/C4
6316/C3
6319M/C3
6319/C3
Material
Regreasable bearings
Stainless steel
Frame material
Cover material
Cable entries
2xM40x1.5
2xM63 + 2xM20
Terminals
Fan
Material
Fan cover
Material
Steel
Connections
Stator winding
Rotor winding
355
Material
Lubrication
Rating plate
200
Paint thickness
Material
Copper
Insulation
Insulation class F
Winding protection
On request
Material
Balancing method
Key way
Enclosure
IP 55
Cooling method
IC 411
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006
143
144
ABB LV Motors / Cat. BU / Low Voltage General Purpose Motors / Cast iron EN 12-2006