FRIALIT & XiVE

Catalog

FRIALIT & XiVE

ANKYLOS FRIOS

PEPGEN P-15

FRIALIT & XiVE Catalog

FRIALIT & XiVE Two implant designs, one prosthesis!

FRIALIT The root-analog implant with unlimited prosthetic options for ultimate esthetics. XiVE The implant design for accelerated treatment with highest primary stability in all bone qualities. Ultimate esthetics and accelerated treatment the FRIALIT and XiVE implant options cover all indications. The identical implant-abutment-connection of FRIALIT and XiVE S implants provides a unique platform for the optimal realization of all prosthetic concepts using the components of FRIADENT Prosthetics.

FRIADENT Prosthetics

XiVE TG Prosthetics

XiVE TG The transgingival alternative. Single-stage transgingival XiVE TG Screw Implants are available in addition to the subgingival implant design. The superstructure is produced with XiVE TG prosthetic line components.

FRIALIT Implants

XiVE S Implants

XiVE TG Implants

Information regarding the materials involved in implants, system components and instruments is given in the form of a reference number after every article: FRIADENT Gingiva Former2. Page 87 of this catalog presents an overview of the materials and the composition of the materials used.

The pictures in this catalog are for illustration. The size of the illustrated products may deviate from the original product. DENTSPLY Friadent reserves the right to make any technical changes without prior notice.

Content

FRIALIT Implants
Pre-surgical planning Implant placement Instruments for implant placement

4 6 9 12 20 22 24 28 38 42

XiVE Implants
Pre-surgical planning Implant placement Instruments for implant placement

FRIADENT Prosthetics
Uncovery Fabrication of superstructure at implant level Soft tissue management, Provisional restorations Impression making Prosthetics/laboratory Fabrication of superstructure at gingival level (MP-Abutment) Transgingival extension, temporary sealing Impression making Prosthetics/laboratory Instruments for impression making/ prosthetics/laboratory

43 46 49

55 57 58 62 66 68 70 72 73 76 78 79 79

XiVE TG Implants and Prosthetics


Implant placement Instruments for implant placement Impression making Prosthetics/laboratory Instruments for impression making/ prosthetics/laboratory

Presentation material Appendix


Materials

Additional DENTSPLY Friadent Product Catalogs Order No. 6-252004 for ANKYLOS Order No. 6-302017 for FRIOS and PEPGEN P-15

Presentation material

XiVE TG

FRIADENT Prosthetics

for FRIALIT & XiVE S


XiVE

FRIALIT

FRIALIT

FRIALIT plus Implants Prevention instead of intervention for perfect esthetics


Innovative esthetic implant concepts should consider tooth-by-tooth replacement as early as possible. FRIALIT, the first root-analog implant geometry in the world, offers perfect esthetics of peri-implant soft tissues, excellent prosthetic results and long-term success. Following natures design, FRIALIT implants stepped design ensures an optimum transfer of occlusal forces. The anatomical diameters allow support of the alveolar bone, reconstruction of the interproximal space and maintenance of the papillae. Perforating the buccal plate or injuring converging roots during surgery can be avoided since the apical end of the implant is narrower. The implant-abutment connection provides the utmost in stability with long parallel-walled sections to resist lateral forces and a deep internal hex to prevent rotation.

Indications
Cases: where hard and soft tissue atrophy can be prevented through immediate or delayed-immediate implant placement with high esthetic demands, particularly in the anterior region requiring a natural emergence profile based on the crestal-anatomical implant diameter where trauma to the labial or buccal wall or adjacent anatomical structures can be prevented by using rootanalog stepped implants planned for tooth-by-tooth reconstruction

Macro-design
Root-analog, stepped design provides functional transfer of occlusal forces, supports peri-implant bone and overlying soft tissue. The interproximal space and the papillae are preserved based on the anatomy.

Micro-design
The synchronized thread design of the FRIALIT plus stepped screw offers increased self-tapping efficiency in cortical bone and optimum primary stability with secure retention in soft spongy bone ideal in all bone qualities.

Nano-design
Growth-activating FRIADENT plus surface. Stepped screw implant with trimodal surface morphology providing an ideal environment for functional adaptation of epithelium, connective tissue and bone.

Implant diameters D 3.4 FRIALIT

D 3.8

D 4.5

D 5.5

D 6.5

FRIALIT

Pre-surgical planning

Order No.

Article

FRIADENT Select Try-in Abutments and Sleeves can be used either for FRIALIT or XiVE implants. The design of the Select Try-in Abutments has been adapted to the special implant geometries. Therefore, different Try-in Implants (FRIALIT or XiVE) have to be used for FRIALIT and XiVE.

45 5020

FRIALIT Select Basic Set Complete The Basic Set includes for each implant diameter one straight FRIADENT Select Try-in Abutment and the D 3.4 and D 3.8/A 15 angled Select Try-in Abutment one FRIADENT Select Sleeve and the pin one FRIALIT Select Try-in Implant Implant Forceps one Select Tray

Try-in Abutments

Gingival height, angulation and the correct position of the horizontal screw (GH 2) for FRIADENT abutments can easily and quickly be determined with the FRIADENT Select Try-in Abutments.
45 2190 FRIADENT Basic Set Select Try-in Abutment The Basic Set consists of a FRIADENT Select Try-in Abutment A 0, straight for each implant diameter and the FRIADENT Select Try-in Abutments D 3.4 and D 3.8/A 15, angled. FRIADENT Select Try-in Abutment2 45 45 45 45 45 45 2120 2121 2122 2123 2220 2221 D D D D D D 3.4/A 3.8/A 4.5/A 5.5/A 3.4/A 3.8/A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 15 (angled 15) 15 (angled 15)

FRIADENT Select Multipack Try-in Abutment (3 pieces) 45 45 45 45 45 45 2193 2194 2195 2196 2293 2294 D D D D D D 3.4/A 3.8/A 4.5/A 5.5/A 3.4/A 3.8/A 0 (straight, 3 pieces) 0 (straight, 3 pieces) 0 (straight, 3 pieces) 0 (straight, 3 pieces) 15 (angled 15, 3 pieces) 15 (angled 15, 3 pieces)

Order No. Sleeves

Article

FRIADENT Select Sleeves allow for an exact transfer of the pre-prosthetic planning to the clinical situation.
45 5090 FRIADENT Select Basic Set Sleeve The Basic Set contains one pin and one FRIADENT Select Sleeve per implant diameter. FRIADENT Select Sleeve2 without pin 45 45 45 45 45 5035 5045 5055 5065 5075 D D D D D 3.4 3.8 4.5 5.5 6.5

FRIADENT Multipack Select Sleeve (3 pieces, without pin) 45 45 45 45 45 5095 5091 5092 5093 5094 D D D D D 3.4 3.8 4.5 5.5 6.5 (3 (3 (3 (3 (3 pieces) pieces) pieces) pieces) pieces)

91 4502

FRIADENT Khoury Drill Guide Pin2

Try-in Implants

With FRIALIT Select Try-in Implants you can verify implant position, implant axis and the implant position in relation to the bone crest during surgery. The thickness of the the soft tissue can be measured.
45 5080 FRIALIT Select Basic Set Try-in Implant The Basic Set contains one FRIALIT Select Try-in Implant per implant diameter. FRIALIT Select Try-in Implant2 45 45 45 45 45 5030 5040 5050 5060 5070 D D D D D 3.4 3.8 4.5 5.5 6.5

FRIALIT Multipack Select Try-in Implant (3 pieces) 45 45 45 45 45 5085 5081 5082 5083 5084 D D D D D 3.4 3.8 4.5 5.5 6.5 (3 (3 (3 (3 (3 pieces) pieces) pieces) pieces) pieces) 7

FRIALIT

Pre-surgical planning

Order No. 48 0040

Article FRIALIT Select Tray (empty)

Others 49 1211 FRIADENT Radiographic Balls for pre-surgical planning6 ( 5 mm), quantity: 12 FRIALIT Radiographic Template (Scales 1:1; 1.3 :1; 1.7 :1)

45 5570

Implant placement

FRIADENT sterile packaging for implants


All FRIADENT implants are packed in gamma sterilized, sealed transparent double vials. An adhesive label seals the color-coded cap with the non-sterile outer vial. The blister is also non-sterile.

No-touch insertion FRIALIT implants

1. Remove the cap from the outer vial (non-sterile)

Transparent outer vial to see the content Color-coded cap displaying the implant length for clear identification Sterile inner vial with implant retaining stopper for fast and safe no-touch placement of implants Peel-off labels for a reliable documentation
and slide the inner vial (sterile) onto the surgical tray.

FRIADENT sterile packaging for FRIALIT Screw Implants

2. Remove the implant via the silicone stopper without touching the inner vial.

Color-coded cap matching the implant diameter

3. Insert the FRIALIT implant dependent on the implant type. Please follow the instructions for use.

Cover screw Retaining stopper

Stepped screw with placement head Polycarbonate inner vial (sterile)

Outer vial (non-sterile) The Cover Screw of FRIALIT Stepped Cylinders is already in the implant.

The undamaged label clearly indicates that the sterile package has not been opened and thus product sterility.
9

FRIALIT

10

Implant placement

Order No.

Article

Implants (sterile) FRIALIT plus Stepped Screw Content: Stepped Screw, Placement Head2 and Cover Screw2 36 0431 36 0433 36 0435 36 0441 36 0443 36 0445 36 36 36 36 36 36 36 36 0450 0451 0453 0455 0460 0461 0463 0465 D 3.4/L 11 3 D 3.4/L 13 3 D 3.4/L 15 3 D 3.8/L 11 2 D 3.8/L 13 2 D 3.8/L 15 2 D D D D D D D D 4.5/L 4.5/L 4.5/L 4.5/L 5.5/L 5.5/L 5.5/L 5.5/L 82 10 2 13 2 15 2 82 10 2 13 2 15 2

36 0471 36 0473 36 0475

D 6.5/L 10 2 D 6.5/L 13 2 D 6.5/L 15 2

Before rotating the FRIALIT Screw Implant into place, the Placement Head is removed with the 0.9 mm FRIADENT Hex Driver. To complete the insertion, use the FRIALIT Stepped Screw Implant Driver for ratchet or handpiece (see page 18). The Cover Screw for FRIALIT Stepped Screw Implants is located in the silicone stopper of the inner vial. The Cover Screws are seated in with the 0.9 mm FRIADENT Hex Driver or with the blade width 2.0 mm FRIADENT Screwdriver.

FRIADENT Cover Screw for Implants2 45 45 45 45 45 1130 1140 1150 1160 1170 D D D D D 3.4 3.8 4.5 5.5 6.5

11

FRIALIT

Instruments for implant placement

The FRIALIT drill sequence


A successful implant placement requires precise and careful implant site preparation. Therefore, please follow our recommendations for drilling exactly. FRIALIT Twist Drills and Stepped Drills FRIALIT Twist Drills and Stepped Drills are used at 800 rpm. In very dense cortical bone the diameter 5.5 mm and 6.5 mm stepped drills are used at a maximum speed of 400 to 500 rpm. During the preparation make sure drills are adequately internally and externally irrigated. FRIALIT Cortical Drill Dense cortical bone (type I bone) frequently exhibits elastic forces after implant site preparation. Additional preparation of the top step with the FRIALIT Cortical Drill can compensate for this effect. The FRIALIT Cortical Drill gently expands the implant site as required by increasing the diameter of the first step by 1/10 mm and thus allows for an easy and atraumatic implant insertion avoiding a too high insertion torque.

FRIALIT Stepped Screw D 3.4 FRIALIT Stepped Cylinder D 3.4

FRIALIT Twist Drill D 2.0 FRIALIT Round Drill

FRIALIT Stepped Drill D 3.4

FRIALIT Stepped Screw D 3.8 FRIALIT Stepped Cylinder D 3.8

FRIALIT Stepped Screw D 4.5 FRIALIT Stepped Cylinder D 4.5

FRIALIT Stepped Screw D 5.5 FRIALIT Stepped Cylinder D 5.5

FRIALIT BoneCondenser In cases of poor bone quality, FRIALIT BoneCondensers can be used for lateral and apical implant site condensation. This improvement of bone quality and quantity enhances primary implant stabilization.

FRIALIT Stepped Screw D 6.5 FRIALIT Stepped Cylinder D 6.5

12

FRIALIT Stepped Drill D 3.8

Cortical Drill D 3.8

FRIALIT Stepped Drill D 4.5

Cortical Drill D 4.5

FRIALIT Stepped Drill D 5.5

Cortical Drill D 5.5

FRIALIT Stepped Drill D 6.5

Cortical Drill D 6.5

For type I bone

13

FRIALIT

Instruments for implant placement

Order No.

Article

FRIALIT Sets Surgical Instruments The instrument sets contain all instruments required for implant placement. The kits are supplied in the new FRIALIT Surgical Tray. 45 8072 45 8090 FRIALIT Basic Set Surgery FRIALIT Expert Set Surgery

Contents: Radiographic Balls for pre-surgical planning (5 pcs.) FRIALIT Select Try-in Implant StarterSet FRIALIT Select Try-in Implant D 3.4

StarterSet

ExpertSet

Contents: Handpiece Stepped Screw Implant Driver D 3.8 D 6.5 Handpiece Stepped Screw Implant Driver D 3.4 Ratchet Stepped Screw Implant Driver 12 mm 16 mm 20 mm FRIADENT Ratchet FRIADENT Ratchet Insert for Implant Driver Seating Instrument for Cylinder Implants standard Seating Instrument for Cylinder Implants posterior Handpiece Hex Driver 0.9 mm Ratchet Hex Driver 0.9 mm Handpiece Slot Screwdriver Ratchet Slot Screwdriver Implant Forceps Surgical Tray

StarterSet

ExpertSet

FRIADENT Select Try-in Abutment StarterSet FRIADENT Select Try-in Abutment D 3.4 FRIADENT Select Try-in Abutment D 3.4/A 15 (angled 15) Fitting Tool for Depth Stops Depth Gauge D 2

Twist Drill D 2 (with 4 Depth Stops) Stepped Drill D 3.4 (with 5 Depth Stops) Round Drill Stepped Drill D 3.8 universal (with 4 Depth Stops) Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D 4.5/L 4.5/L 4.5/L 4.5/L 5.5/L 5.5/L 5.5/L 5.5/L 8 10 13 15 8 10 13 15

Stepped Drill D 6.5/L 10 Stepped Drill D 6.5/L 13 Stepped Drill D 6.5/L 15 Cortical Drill D Cortical Drill D Cortical Drill D Cortical Drill D 3.8 4.5 5.5 6.5

Drill Extension Long Internal Irrigation Tube Drill Cleaning Instrument

14

Order No. Drills6

Article

All FRIALIT Drills are provided with internal irrigation. Please replace the cutting instruments after approximately 20 uses or if they are damaged or dull.
45 5102 45 5130 FRIALIT Twist Drill D 26 (with 4 Depth Stops) FRIALIT Round Drill6 FRIALIT Stepped Drill6 45 5331 45 5340 45 45 45 45 45 45 45 45 5350 5351 5353 5355 5360 5361 5363 5365 D 3.4 universal (with 5 Depth Stops) D 3.8 universal (with 4 Depth Stops) D D D D D D D D 4.5/L 4.5/L 4.5/L 4.5/L 5.5/L 5.5/L 5.5/L 5.5/L 8 10 13 15 8 10 13 15

45 5371 45 5373 45 5375 45 5101

D 6.5/L 10 D 6.5/L 13 D 6.5/L 15 FRIALIT Drill Depth Stop Tool6 (two-piece) FRIALIT Cortical Drill6

45 45 45 45

5349 5359 5369 5379

D D D D

3.8 4.5 5.5 6.5

The FRIALIT Cortical Drill is used to prepare the coronal section of the implant site in very dense cortical bone.

45 5280 91 0003 90 5042 90 5043

FRIADENT Drill Cleaning Instrument6 FRIADENT Drill Extension6 FRIOS Contra-angle Handpiece 20:1 Irrigation Tube Long Internal Irrigation Tube (for Drill Extension)

The drill extension must always be used with the long internal irrigation tube.

15

FRIALIT

Instruments for implant placement

Order No.

Article

FRIALIT BoneCondenser

FRIALIT BoneCondenser can be used in reduced bone quality to condense the lateral and apical bone of the implant site. The improved bone quality and quantity increases implant primary stability.

FRIALIT Instrument Set BoneCondenser, straight with tray 45 8550 45 8560 45 8570 Instruments Set for diameter D 3.8 D 4.5 (surgical tray with six instruments) Instruments Set for diameter D 3.8 D 5.5 (surgical tray with nine instruments) Instruments Set for diameter D 3.8 D 6.5 (surgical tray with twelve instruments) FRIALIT BoneCondenser, straight25/6 45 5402 45 5403 45 5440 45 5451 45 5453 45 5455 45 5461 45 5463 45 5465 45 5471 45 5473 45 5475 D 2.0 D 3.0 D 3.8 D 4.5 /L 10 D 4.5 /L 13 D 4.5 /L 15 D 5.5 /L 10 D 5.5 /L 13 D 5.5 /L 15 D 6.5 /L 10 D 6.5 /L 13 D 6.5 /L 15

FRIALIT Instrument Set BoneCondenser, angled with tray 45 8950 45 8960 45 8970 Instruments Set for diameter D 3.8 D 4.5 (surgical tray with six instruments) Instruments Set for diameter D 3.8 D 5.5 (surgical tray with nine instruments) Instruments Set for diameter D 3.8 D 6.5 (surgical tray with twelve instruments)

16

Order No.

Article FRIALIT BoneCondenser, angled25/6

45 5902 45 5903 45 5940 45 5951 45 5953 45 5955 45 5961 45 5963 45 5965 45 5971 45 5973 45 5975

D 2.0 D 3.0 D 3.8 D 4.5 /L 10 D 4.5 /L 13 D 4.5 /L 15 D 5.5 /L 10 D 5.5 /L 13 D 5.5 /L 15 D 6.5 /L 10 D 6.5 /L 13 D 6.5 /L 15

The angled FRIALIT BoneCondenser are used when limited space is available and for the posterior region.
48 0060 FRIALIT BoneCondenser Tray5/6/26 (empty)

FRIALIT BoneExpander

FRIALIT BoneExpander are used for the local expansion of the narrow atrophied jaw.
45 8870 FRIALIT Instrument Set BoneExpander with tray Instruments Set for diameter D 3.8 D 6.5 (surgical tray with twelve instruments)

FRIALIT BoneExpander25/6 45 5802 45 5803 45 5840 45 5851 45 5853 45 5855 45 5861 45 5863 45 5865 45 5871 45 5873 45 5875 48 0050 D 2.0 D 3.0 D 3.8 D 4.5 /L 10 D 4.5 /L 13 D 4.5 /L 15 D 5.5 /L 10 D 5.5 /L 13 D 5.5 /L 15 D 6.5 /L 10 D 6.5 /L 13 D 6.5 /L 15 FRIALIT BoneExpander Tray5/6/26 (empty) 17

FRIALIT

Instruments for implant placement

Order No.

Article

FRIADENT Periotome

The FRIADENT Periotome is ideally designed for atraumatic residual root and tooth removal.

45 5500

FRIADENT Periotome Handle6 FRIADENT Periotome Blade6

45 5501 45 5502 45 5503

P 1 (straight, wide) P 2 (straight, narrow) P 3 (angled, narrow)

Other instruments 45 5106 45 5709 45 5711 FRIADENT Paralleling Pin2 FRIADENT Ratchet6, without inserts FRIADENT Ratchet Insert for Implant Driver6 FRIALIT Ratchet Stepped Screw Implant Driver6 12 mm 16 mm 20 mm FRIALIT Handpiece Stepped Screw Implant Driver4 for D 3.4 for D 3.8 D 6.5

46 5512 46 5516 46 5520

45 5519 45 5510

45 5104 45 5100

FRIADENT Depth Gauge2 D 2.0 D 3.0

18

Order No.

Article FRIADENT Handpiece Hex Driver6 width 0.9 mm FRIADENT Handpiece Slot Screwdriver6 blade width 2.0 mm FRIADENT Ratchet Hex Driver6 with torque limit width 0.9 mm/14 Ncm/short width 0.9 mm/14 Ncm/long width 1.22 mm/24 Ncm/short width 1.22 mm/24 Ncm/long FRIADENT Ratchet Slot Screwdriver6 with torque limit blade width 2.0 mm/14 Ncm/short blade width 2.0 mm/14 Ncm/long FRIADENT Hex Driver6 without torque limit width 0.9 mm

45 5651

45 5640

45 45 45 45

5732 5733 5734 5736

45 5714 45 5722

45 5650

The 0.9 mm FRIADENT Hex Driver without torque limit is recommended for regions with limited access.

91 4510 91 4515

FRIADENT Implant Mallet6/20 FRIADENT Implant Forceps2 (titanium) FRIALIT Trephine Drill6

45 45 45 45 45

5654 5655 5656 5657 5658

D D D D D

3.4 3.8 4.5 5.5 6.5

19

FRIALIT

XiVE

XiVE plus Implants As simple as possible, as flexible as necessary


The goal of implant dentistry is to make treatment simpler, faster and as easy as possible for your patients. The XiVE implants offer an accelerated procedure with multiple prosthetic options without requiring expensive and complicated surgical and laboratory techniques. XiVE cylindrical screw implants combine increased primary stability in all types of bone with a standardized prosthetic platform including the option of immediate loading. Through its thread design and simplified surgical procedure, XiVE offers an implant for all types of bone. The internal implant-abutment connection, which has been proven for over 10 years, is fully compatible with the prosthetic components and instruments of FRIALIT. This universal prosthetic platform technology greatly simplifies life for the restorative dentist.

20

Indications
Cases: with atrophied ridges where augmentation is not desired or indicated multiple implant restorations in posterior regions where a cylindrical implant design is advantageous particularly in the lateral region where a subgingival and/or a transgingival implant design is indicated with limited interproximal space: narrowest implant diameter = 3.0 mm where the local bone must be used to the maximum possible extent: implant lengths available range from 8 to 18 mm requiring increased primary stability for early or immediate implant function when temporary and definitive components are needed for simple and fast prosthetic restoration

Macro-design
The cylinder-shaped design for internal condensation of the peri-implant bone prevents trauma and increases primary stability of implants, even in spongy bone.

Micro-design
The innovative thread design of XiVE screw implants combined with the bone-class-specific preparation of the implant site provides torque stabilization in all bone qualities.

Nano-design
Growth-activating FRIADENT plus surface. Screw implant with trimodal surface morphology providing an ideal environment for functional adaptation of epithelium, connective tissue and bone.

Implant diameters D 3.0 XiVE S XiVE TG

D 3.4

D 3.8

D 4.5

D 5.5

21

XiVE TG

Article overview XiVE TG see page 66

XiVE

Pre-surgical planning

Order No.

Article

Try-in Abutments

Gingival height, angle and the correct position of the horizontal screw (GH 2) for FRIADENT abutments can easily and quickly be determined with the FRIADENT Select Try-in Abutments.
FRIADENT Select Try-in Abutments2 45 45 45 45 45 45 45 45 2119 2120 2121 2122 2123 2219 2220 2221 D D D D D D D D 3.0/A 3.4/A 3.8/A 4.5/A 5.5/A 3.0/A 3.4/A 3.8/A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 0 (straight) 15 (angled 15) 15 (angled 15) 15 (angled 15)

Sleeves

FRIADENT Select Sleeves allow for an exact transfer of the pre-prosthetic planning to the clinical situation.
FRIADENT Select Sleeves2 without pin 45 45 45 45 45 5025 5035 5045 5055 5065 D D D D D 3.0 3.4 3.8 4.5 5.5

91 4502

FRIADENT Khoury Drill Guide Pin2

22

Order No. Try-in Implants

Article

26 1510 26 1500

XiVE Depth Gauge2 D 2.0 XiVE Select Basic Set Try-in Implant The Basic Set contains one XiVE Select Try-in Implant per implant diameter (D 3.0 D 5.5). XiVE Select Try-in Implant2

26 26 26 26 26

1520 1530 1540 1550 1560

D D D D D

3.0 3.4 3.8 4.5 5.5

Others 49 1211 26 9020 25 5206 FRIADENT Radiographic Balls for pre-surgical planning6 ( 5 mm), 12 pieces XiVE Radiographic Template (subgingival) XiVE TG Radiographic Template (transgingival)

23

XiVE

With XiVE Select Try-in Implants you can verify implant position, implant axis and the implant position in relation to the bone crest during surgery. The thickness of the soft tissue can be measured.

24

Implant placement

FRIADENT sterile packaging for screw implants


All FRIADENT screw implants are packaged in gammasterilized, sealed transparent double vials with colorcoded caps.

No-touch insertion XiVE S plus Screw Implant


1. Remove the outer vial cap (non sterile) and drop the sterile inner vial onto the surgical tray. 2. Remove the silicone stopper from the inner vial. The implant cover screw is located in the silicone stopper of the inner vial. 3. Place the XiVE Ratchet or Handpiece Implant Driver D 3.4/TempBase into the internal hex of the FRIADENT TempBase. 4. Remove the implant without touching the inner vial.

Transparent outer vial to see the content Color-coded cap displaying the implant length for clear identification Sterile inner vial with implant retaining stopper for fast and safe no-touch placement of implants Peel-off labels for a reliable documentation

FRIADENT sterile packaging for XiVE S plus Screw Implants

Retaining stopper: contains implant cover screw

Implant holder Inner vial (sterile): contains implant and TempBase (pre-mounted to implant) Outer vial (non-sterile)

5. By doing so, the implant holder falls apart in two halves.

6. Insert the XiVE S plus Screw Implant. Please follow the instructions for use.

The undamaged label clearly indicates that the sterile package has not been opened and thus product sterility.

25

XiVE

Implant placement

Order No.

Article

Implants (sterile) XiVE S plus Screw Implant Content: Screw Implant2, TempBase2, Cover Screw2 26 1422 26 1423 26 1425 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 1431 1432 1433 1435 1438 1440 1441 1442 1443 1445 1448 1450 1451 1452 1453 1455 1458 1460 1461 1462 1463 1465 D 3.0/L 11 D 3.0/L 13 D 3.0/L 15 D D D D D D D D D D D D D D D D D D D D D D 3.4/L 3.4/L 3.4/L 3.4/L 3.4/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 4.5/L 4.5/L 4.5/L 4.5/L 4.5/L 4.5/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L 9,5 11 13 15 18 8 9,5 11 13 15 18 8 9,5 11 13 15 18 8 9,5 11 13 15

All XiVE S Screw Implants are packaged with the FRIADENT TempBase for mounting the implant driver. To rotate the XiVE S Screw Implant into place, use the XiVE Driver for Ratchet or Handpiece (see page 36). Once the implant is seated, the TempBase Retaining Screw is loosened with the 0.9 mm FRIADENT Hex Driver. Then the TempBase removed. The Cover Screw for XiVE S Screw Implants is located in the silicone stopper of the inner vial. The Cover Screws are threaded in with the 0.9 mm FRIADENT Hex Driver.

26

Order No.

Article

FRIADENT TempBase

In addition, with the FRIADENT TempBase Cap (please order separately) the TempBase can be used for an immediate registration to fabricate a temporary during the healing period an immediate provisional restoration (single tooth or multiple implant provisional).
FRIADENT TempBase with Retaining Screw TempBase 46 46 46 46 46 1220 1230 1240 1250 1260 D D D D D 3.0 4 3.4 4 3.8 4 4.5 4 5.5 4

FRIADENT TempBase Cap28 46 1235 46 1255 46 1265 D 3.0 and D 3.8 D 4.5 D 5.5 FRIADENT Retaining Screw TempBase4 46 1279 46 1280 D 3.0 D 3.4 D 5.5

FRIADENT Cover Screw for Implants2 45 45 45 45 45 1120 1130 1140 1150 1160 D D D D D 3.0 3.4 3.8 4.5 5.5

27

XiVE

The FRIADENT TempBase serves as implant holder and placement head. It is included in the XiVE S plus Screw Implant.

Instruments for implant placement

The XiVE drill sequence


A successful implant placement requires precise and careful implant site preparation. Therefore, please follow our recommendations for drilling exactly. Pilot hole: XiVE D 2.0 Twist Drill (posterior or anterior) XiVE Twist Drills and Twist Drills crestal are used at 800 rpm. During the preparation make sure drills are adequately internally and externally irrigated. Optimum flow volume is guaranteed if separate sources are used for internal and external irrigation. Marking: XiVE Round Drill Preparation of the implant site: XiVE Twist Drill (posterior or anterior), starting with D 3.0 and increasing in diameter until the final implant diameter is reached.
Twist Drill anterior
18 mm 15 mm 13 mm 11 mm 9,5 mm 8 mm

XiVE S plus all implants D 3.0

XiVE Twist Drill posterior or anterior D 2.0

XiVE Round Drill

XiVE S plus and XiVE TG plus all implants D 3.4


XiVE S plus and XiVE TG plus all implants D 3.8


Twist Drill posterior XiVE TG L 13 XiVE S L 13


0,5 mm

XiVE S plus and XiVE TG plus all implants D 4.5


XiVE S plus all implants D 5.5

Crestal depth preparation

Crestal preparation to achieve the internal condensation effect: XiVE Twist Drill crestal
2 mm

6 mm

The crestal drilling varies between 2 and 6 mm based on the bone quality. Thus, an optimal primary stability of the implant in all types of bone is achieved.

Bone D I D III: up to 6 mm

Bone D IV: 2 mm

Pre-tapping the implant site in type I bone

Pre-tapping the implant thread: In very cortical bone, pre-tapping of the implant site at 15 rpm is required in the crestal area after the initial 6 mm deep preparation. The XiVE Tap can be used to reduce the crestal torque achieved during insertion of implants.

28

For type I bone


XiVE Twist Drill posterior or anterior D 3.0

XiVE Twist Drill posterior or anterior D 3.4

XiVE Twist Drill crestal D 3.4

XiVE Tap D 3.4

XiVE Twist Drill posterior or anterior D 3.8

XiVE Twist Drill crestal D 3.8

XiVE Tap D 3.8

XiVE Twist Drill posterior or anterior D 4.5

XiVE Twist Drill crestal D 4.5

XiVE Tap D 4.5

XiVE Twist Drill posterior or anterior D 5.5

XiVE Twist Drill crestal D 5.5

XiVE Tap D 5.5

XiVE BoneCondenser: In cases of poor bone quality, XiVE BoneCondensers can be used for lateral and apical implant site condensation. This improvement of bone quality and quantity enhances primary implant stabilization.

29

XiVE

XiVE Twist Drill crestal D 3.0

XiVE Tap D 3.0

Instruments for implant placement

Order No.

Article

XiVE Instrument Sets Surgery The XiVE Instrument Sets Surgery contain the instruments required for implant placement. The kits are supplied in the XiVE Surgical Tray. 26 8000 26 8005
Contents: Radiographic Balls for pre-surgical planning XiVE S Radiographic template XiVE TG Radiographic template

XiVE Expert Set Surgery XiVE Standard Set Surgery


Expert Standard Set Set 5 1 1 1 1 1 1 1 1 1 1 3 5 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contents: Long Internal Irrigation Tube Drill Cleaning Instrument Expert Standard Set Set 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

FRIADENT Select Try-in Abutment D 3.0/A 0 FRIADENT Select Try-in Abutment D 3.4/A 0 FRIADENT Select Try-in Abutment D 3.8/A 0 FRIADENT Select Try-in Abutment D 4.5/A 0 FRIADENT Select Try-in Abutment D 5.5/A 0 FRIADENT Select Try-in Abutment D 3.0/A 15 FRIADENT Select Try-in Abutment D 3.4/A 15 FRIADENT Select Try-in Abutment D 3.8/A 15

Depth Gauge D 2.0 XiVE Select Try-in Implant D XiVE Select Try-in Implant D XiVE Select Try-in Implant D XiVE Select Try-in Implant D XiVE Select Try-in Implant D 3.0 3.4 3.8 4.5 5.5

1 1 1 1 1 1 1 1

Ratchet Implant Driver posterior for Screw Implants D 3.0 1 Ratchet Implant Driver posterior for Screw Implants and TempBase D 3.4D 6.5 1 Ratchet Implant Driver anterior for Screw Implants D 3.0 1 Ratchet Implant Driver anterior for Screw Implants and TempBase D 3.4D 6.5 1 Handpiece Implant Driver posterior for Screw Implants D 3.0 1 Handpiece Implant Driver posterior for Screw Implants and TempBase D 3.4 1 Handpiece Implant Driver posterior for Screw Implants D 3.8D 6.5 1 Handpiece Implant Driver anterior for Screw Implants D 3.0 1 Handpiece Implant Driver anterior for Screw Implants and TempBase D 3.4 1 Handpiece Implant Driver anterior for Screw Implants D 3.8D 6.5 1 Ratchet Implant Driver TG 1 Handpiece Implant Driver TG 1 FRIADENT Ratchet FRIADENT Ratchet Insert for Implant Driver Handpiece Hex Driver 0.9 mm/short Handpiece Hex Driver 0.9 mm/long Handpiece Hex Driver 1.22 mm/short Handpiece Hex Driver 1.22 mm/long Handle for Contra-angle Hex Driver Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 0.9 mm/long Ratchet Hex Driver 1.22 mm/short Ratchet Hex Driver 1.22 mm/long Implant Forceps XiVE Surgical Tray 1 1 1 1 1 1 1 1 1 1 1 1 1

Twist Drill posterior D 2.0/L 815 Twist Drill anterior D 2.0/L 818 Round Drill Twist Drill posterior D Twist Drill posterior D Twist Drill posterior D Twist Drill posterior D Twist Drill posterior D Twist Drill anterior D Twist Drill anterior D Twist Drill anterior D Twist Drill anterior D Twist Drill anterior D Twist Drill crestal D Twist Drill crestal D Twist Drill crestal D Twist Drill crestal D Twist Drill crestal D XiVE Tap Set Drill Extension 3.0/L 3.4/L 3.8/L 4.5/L 5.5/L 815 815 815 815 815

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3.0/L 3.4/L 3.8/L 4.5/L 5.5/L

818 818 818 818 818

3.0 3.4 3.8 4.5 5.5

30

Order No.

Article

XiVE Security Kits

26 1200 26 1205

XiVE Expert Security Kit (posterior/anterior) XiVE Standard Security Kit (posterior only)

Contents: Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D XiVE Security Kit Tray 2.0D 2.0D 2.0D 2.0D 2.0D 3.4D 3.4D 3.4D 3.4D 3.4D 4.5D 4.5D 4.5D 4.5D 4.5D 3.0/L 3.0/L 3.0/L 3.0/L 3.0/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L 8 9.5 11 13 15 8 9.5 11 13 15 8 9.5 11 13 15

ExpertSet 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

StandardSet 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2.0D 2.0D 2.0D 2.0D 2.0D 2.0D 3.4D 3.4D 3.4D 3.4D 3.4D 3.4D 4.5D 4.5D 4.5D 4.5D 4.5D 4.5D

3.0/L 3.0/L 3.0/L 3.0/L 3.0/L 3.0/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L

8 9.5 11 13 15 18 8 9.5 11 13 15 18 8 9.5 11 13 15 18

The XiVE Depth Stops are mounted and removed from the XiVE drill manually, over the cutting end. No additional instruments are necessary.

26 8010 26 1390

XiVE Surgical Tray (empty) XiVE Security Kit Tray (empty) 31

XiVE

The XiVE Security Kits contain all depth stops required for using the universal XiVE Twist Drills. The kits are supplied in the XiVE Security Tray.

Instruments for Implant Placement

Order No. Drills

Article

XiVE Single-patient Drills (single articles) 26 1015 26 1025 26 1035 26 1045 26 1055 26 1065 D 2.0/L 8 L 15 D 3.0/L 8 L 15 D 3.4/L 8 L 15 D 3.8/L 8 L 15 D 4.5/L 8 L 15 D 5.5/L 8 L 15

Article sets

The XiVE Single-patient Drill Sets include all twist drills required for implant site preparation of the appropriate implant diameter. Once this diameter has been reached, the XiVE Twist Drill crestal has to be used additionally.

26 3025

XiVE Single-patient Drill Set D 3.0/L 8 L 15 XiVE Single-patient Drill Set D 3.4/L 8 L 15

26 3035

26 3045

XiVE Single-patient Drill Set D 3.8/L 8 L 15

26 3055

XiVE Single-patient Drill Set D 4.5/L 8 L 15

26 3065

XiVE Single-patient Drill Set D 5.5/L 8 L 15

32

Order No.

Article

All XiVE Drills are provided with internal irrigation. Please replace the cutting instruments after approximately 20 uses or if they are damaged or dull.

26 1115 26 1118 26 1110

XiVE Twist Drill posterior6 D 2.0/L 815 XiVE Twist Drill anterior6 D 2.0/L 818 XiVE Round Drill6 XiVE Twist Drill posterior6

26 26 26 26 26

1125 1135 1145 1155 1165

D 3.0/L 815 D 3.4/L 815 D 3.8/L 815 D 4.5/L 815 D 5.5/L 815

XiVE Twist Drill anterior6 26 26 26 26 26 1128 1138 1148 1158 1168 D 3.0/L 818 D 3.4/L 818 D 3.8/L 818 D 4.5/L 818 D 5.5/L 818

The XiVE Twist Drills posterior and anterior are provided with marking grooves for clear distinction:
XiVE Twist Drill crestal6 26 26 26 26 26 1120 1130 1140 1150 1160 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

posterior: 1 groove

anterior: 2 grooves

Once the appropriate diameter has been reached, the crestal preparation leads to an internal condensation of the implant site and thus increases primary stability. The Twist Drill crestal always has to be used. In type I bone, pre-tapping of the implant threads is required in the crestal area after crestal preparation. Therefore, the XiVE Tap (see page 35) has to be used.

33

XiVE

All XiVE Twist Drills are available in one length. The drills are adjusted to the desired implant length by using the respective XiVE Depth Stops. The XiVE Expert Security Kit contains one complete set of depth stops for the XiVE posterior and anterior Twist Drills. The XiVE Standard Security Kit includes only the depth stops for the posterior Twist Drills (see page 31).

Instruments for implant placement

Order No.

Article

Drill Depth Stops XiVE Depth Stop posterior6 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 1210 1211 1212 1213 1215 1230 1231 1232 1233 1235 1250 1251 1252 1253 1255 D D D D D D D D D D D D D D D 2.0 2.0 2.0 2.0 2.0 3.4 3.4 3.4 3.4 3.4 4.5 4.5 4.5 4.5 4.5 3.0/L 3.0/L 3.0/L 3.0/L 3.0/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L 8 9.5 11 13 15 8 9.5 11 13 15 8 9.5 11 13 15

XiVE Depth Stop anterior6 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 1310 1311 1312 1313 1315 1318 1330 1331 1332 1333 1335 1338 1350 1351 1352 1353 1355 1358 D D D D D D D D D D D D D D D D D D 2.0 2.0 2.0 2.0 2.0 2.0 3.4 3.4 3.4 3.4 3.4 3.4 4.5 4.5 4.5 4.5 4.5 4.5 3.0/L 3.0/L 3.0/L 3.0/L 3.0/L 3.0/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L 5.5/L 8 9.5 11 13 15 18 8 9.5 11 13 15 18 8 9.5 11 13 15 18

posterior: 1 groove

anterior: 2 grooves

The XiVE Depth Stops posterior and anterior are also provided with marking grooves for clear distinction. The XiVE Depth Stops are mounted and removed from the XiVE Drill manually, over the cutting end. No additional instruments are necessary.

34

Order No. 45 5280 91 0003 90 5042 90 5043

Article FRIADENT Drill Cleaning Instrument6 FRIADENT Drill Extension6

Long Internal Irrigation Tube (for Drill Extension)

The drill extension must always be used with the long internal irrigation tube.

Taps

In very cortical bone, pre-tapping of the implant site is required in the crestal area after the initial 6 mm deep preparation. The XiVE Tap can be used to reduce the crestal torque achieved during insertion of implants.
26 1180 XiVE Tap Set4 one tap per diameter D 3.0 D 5.5 XiVE Tap4 26 26 26 26 26 1121 1131 1141 1151 1161 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

The XiVE Taps are used with the FRIADENT Ratchet or Handpiece Implant Driver D 3.4/TempBase.

35

XiVE

FRIOS Contra-angle Handpiece 20:1 Irrigation Tube

XiVE

Instruments for implant placement

Order No.

Article

XiVE BoneCondenser

XiVE BoneCondenser can be used in reduced bone quality to condense the lateral and apical bone of the implant site. The improved bone quality and quantity increases implant primary stability. All XiVE BoneCondenser are available in one length. Depth marks at the working tip indicate the preparation depth.

26 1600

XiVE Instrument Set BoneCondenser straight and angled (tray with all XiVE BoneCondensers, straight and angled) XiVE Instrument Set BoneCondenser straight (tray with all XiVE BoneCondensers, straight) XiVE Instrument Set BoneCondenser angled (tray with all XiVE BoneCondensers, angled)

26 1603

26 1606

XiVE BoneCondenser, straight25/6 26 26 26 26 26 26 1610 1620 1630 1640 1650 1660 D 2.0 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

XiVE BoneCondenser, angled25/6 26 26 26 26 26 26 1615 1625 1635 1645 1655 1665 D 2.0 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

The angled XiVE BoneCondenser are used when limited space is available and for the posterior region.
26 1790 XiVE BoneCondenser Tray5/6/26 (empty)

Other Instruments 26 1510 45 5709 45 5711 XiVE Depth Gauge2 D 2.0 FRIADENT Ratchet6, without insert FRIADENT Ratchet Insert for Implant Driver6 36

Order No.

Article

Please use the FRIALIT Implant Drivers 46 5512 and 46 5516 (see page 18) when inserting XiVE S Screw Implants D 3.8 D 5.5 without TempBase.
FRIADENT Handpiece Implant Driver4 posterior for implants D 3.0 posterior for implants D 3.4 and TempBase posterior for implants D 3.8 D 6.5 anterior for implants D 3.0 anterior for implants D 3.4 and TempBase anterior for implants D 3.8 D 6.5 FRIADENT Ratchet Hex Driver6 with torque limit width 0.9 mm/14 Ncm/short width 0.9 mm/14 Ncm/long width 1.22 mm/24 Ncm/short width 1.22 mm/24 Ncm/long FRIADENT Ratchet Slot Screwdriver6 with torque limit blade width 2.0 mm/14 Ncm/short blade width 2.0 mm/14 Ncm/long FRIADENT Handpiece Hex Driver6 width 0.9 mm/short width 0.9 mm/long width 1.22 mm/short width 1.22 mm/long FRIADENT Handpiece Slot Driver6 blade width 2.0 mm/short blade width 2.0 mm/long FRIADENT Implant Driver Manual Long XiVE Trephine Drill 26 26 26 26 26 1129 1139 1149 1159 1169 D 3.0/L 818 D 3.4/L 818 D 3.8/L 818 D 4.5/L 818 D 5.5/L 818

46 46 46 46 46 46

5830 5932 5834 5840 5942 5844

45 45 45 45

5732 5733 5734 5736

45 5714 45 5722

46 46 46 46

5710 5720 5711 5721

46 5712 46 5722 46 5880

37

XiVE

FRIADENT Ratchet Implant Driver2 46 5810 posterior for implants D 3.0 46 5912 posterior for implants D 3.4 and TempBase 46 5820 anterior for implants D 3.0 46 5922 anterior for implants D 3.4 and TempBase

FRIADENT Prosthetics

FRIADENT Prosthetics for FRIALIT and XiVE S Universal compatibility


The FRIALIT and XiVE implant options cover all indications. From the top of the implant, the prosthetic procedure should be as simple as possible. Therefore, DENTSPLY Friadent provides the unique concept of platform technology:

Identical implant-abutment connection


Surgical versatility with unlimited prosthetic flexibility is provided through the universal internal hex connection. A patented connection that has been proven over more than10 years of clinical use for all prosthetic concepts.
2 1

1 2

Patent EP 0438 048 and US 4, 960 381, Internal Hex US Patent 5, 199 873 Mllersten et al., Comparison of strength and failure mode of seven implant systems: An in vitro test. J Prosthet Dent 1997; 78:582-91

FRIALIT Implants

XiVE S Implants

FRIADENT Cover Screw

FRIADENT Gingiva Former

FRIADENT Transfer Coping with TransferCap

FRIADENT ProTect

FRIADENT EsthetiCap

FRIADENT EstheticBase straight and angled, Horizontal or Transverse Screw optional

38

Implant diameters/prosthetic diameters D 3.0 FRIALIT


D 3.4

D 3.8

D 4.5

D 5.5

D 6.5

XiVE S

FRIADENT MP Cover Screw

FRIADENT MP Transfer or PickUp Impression Coping XiVE TG implants: implant-abutmentconnection compatible with FRIADENT MP Abutment

FRIADENT CERCON Abutment

FRIADENT CeraBase

FRIADENT AuroBase

FRIADENT Telescopic Abutment

FRIADENT Ball and Socket Attachment

FRIADENT MP Abutment with Bar Coping or Waxing Sleeve

39

FRIADENT Prosthetics

for FRIALIT & XiVE S

40

FRIADENT Prosthetics
At uncovery, based on the indication, you will decide whether to fabricate the superstructure from the implant level or from the gingival level (MP Abutment).

Impression Making

Single Crowns

Bridges

Overdentures
at implant level pages 43 54

FRIADENT EstheticBase straight or angled FRIADENT Transfer Coping (Transfer Technique)

FRIADENT EstheticBase straight or angled

Telescopic Abutment

FRIADENT Transfer Coping (PickUp Technique)

Telescopic Abutment

FRIADENT FRIADENT CERCON CeraBase Ceramic Abutments

at gingival level (MP Abutment)


FRIADENT MP Impression Coping (Transfer technique) FRIADENT MP Abutment (Bridge) with Castable or Cast-to Waxing Sleeve

pages 55 61
FRIADENT MP Abutment (Bar) with Gold, Titanium or Castable Bar Coping

FRIADENT MP Impression Coping (PickUp Technique)

FRIADENT MP Abutment

41

FRIADENT Prosthetics

for FRIALIT & XiVE S

FRIADENT AuroBase

FRIADENT Attachment

Uncovery

Order No.

Article

Soft Tissue Punches FRIADENT Tissue Punch6 45 45 45 45 45 45 5665 5666 5660 5661 5662 5663 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5

BoneProfiler

In case of implants placed subcrestally, new bone can grow over the implant during the healing phase. With the FRIALIT BoneProfiler, this bone can be removed and the Cover Screw uncovered. The geometry of the FRIALIT BoneProfiler exactly matches that of the Gingiva Former.
FRIADENT BoneProfiler6 45 45 45 45 45 5338 5348 5358 5368 5378 D D D D D 3.4 3.8 4.5 5.5 6.5

45 5300 45 5550

FRIADENT Guide Pin for BoneProfiler FRIADENT Soft Tissue Gauge6

42

Prosthetic fabrication at implant level:

Soft tissue management, provisional restorations


Order No. Article Gingiva Formers FRIADENT Gingiva Former2 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 1421 1422 1423 1425 1431 1432 1433 1435 1441 1442 1443 1445 1451 1452 1453 1455 1461 1462 1463 1465 D D D D D D D D D D D D D D D D 3.0/GH 3.0/GH 3.0/GH 3.0/GH 3.4/GH 3.4/GH 3.4/GH 3.4/GH 3.8/GH 3.8/GH 3.8/GH 3.8/GH 4.5/GH 4.5/GH 4.5/GH 4.5/GH 5.5/GH 5.5/GH 5.5/GH 5.5/GH 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5

1 mm

GH 1
2 mm

3 mm

GH 3
5 mm

D D D D

GH 5

The gingiva formers are threaded in with the 0.9 mm FRIADENT Hex Driver or with the blade width 2.0 mm FRIADENT Slot Screwdriver (see page 64).

Please note: D 3.0 components (bronze) can only be used for XiVE. FRIALIT implants D 6.5 (green) are restored with D 5.5 abutments.

43

FRIADENT Prosthetics

for FRIALIT & XiVE S

GH 2

Prosthetic fabrication at implant level:

Soft tissue management, provisional restorations


Order No. Article FRIADENT Gingiva Former2 Slim 45 1232 45 1233 45 1235 45 1242 45 1243 45 1245 45 1252 45 1253 45 1255 D 3.4/GH 2 D 3.4/GH 3 D 3.4/GH 5 D 3.8/GH 2 D 3.8/GH 3 D 3.8/GH 5 D 4.5/GH 2 D 4.5/GH 3 D 4.5/GH 5

With the FRIADENT Gingiva Former Slim a perfect contouring of the soft tissue can be achieved in cases with limited mesio-distal space. For making impressions, the FRIADENT Transfer Coping Slim (see page 47) is used.
FRIADENT Gingiva Former2 Loop 45 1333 45 1335 45 1343 45 1345 45 1353 45 1355 45 1363 45 1365 D 3.4/GH 3 D 3.4/GH 5 D 3.8/GH 3 D 3.8/GH 5 D 4.5/GH 3 D 4.5/GH 5 D 5.5/GH 3 D 5.5/GH 5

The FRIADENT Gingiva Former Loop allows easy securing of suture material, thus enabling simple and safe soft tissue surgery.

44

Order No.

Article FRIADENT EsthetiCap with Screw for EsthetiCap

46 1730 46 1740 46 1745 46 1750 46 1755 46 1760 46 1765

D 3.4/oval D 3.8/oval D 3.8/triangular D 4.5/oval D 4.5/triangular D 5.5/oval D 5.5/triangular

As anatomical gingiva formers, the FRIADENT EsthetiCap abutments provide perfect anatomical and esthetic peri-implant gingival contours by simple customization.

FRIADENT ProTect Abutment24 with PickUp Guide Pin4 45 45 45 45 1530 1540 1550 1560 D D D D 3.4 3.8 4.5 5.5

The PickUp Guide Pin ensures optimum stability for the provisional abutment.

Please note: D 3.0 components (bronze) can only be used for XiVE. FRIALIT implants D 6.5 (green) are restored with D 5.5 abutments.

45

FRIADENT Prosthetics

for FRIALIT & XiVE S

Provisional Restorations

Prosthetic fabrication at implant level:

Impressions
Order No. Article

FRIADENT Lab Set Transfer Impression The Lab Set Transfer Impression contains Transfer Coping, FRIADENT TransferCap (D 3.0 D 5.5), Standard Abutment Screw (D 3.0 with Abutment Screw D 3.0) and Implant Analog 46 8123 46 8125 46 8133 46 8135 46 8143 46 8145 46 8153 46 8155 46 8163 46 8165 D 3.0/GH 3 D 3.0/GH 5 D 3.4/GH 3 D 3.4/GH 5 D 3.8/GH 3 D 3.8/GH 5 D 4.5/GH 3 D 4.5/GH 5 D 5.5/GH 3 D 5.5/GH 5

FRIADENT Lab Set PickUp Impression The Lab Set PickUp Impression contains Transfer Coping, FRIADENT TransferCap (D 3.0 D 5.5), Standard Abutment Screw (D 3.0 with Abutment Screw D 3.0) and Implant Analog 46 8223 46 8225 46 8233 46 8235 46 8243 46 8245 46 8253 46 8255 46 8263 46 8265 D 3.0/GH 3 D 3.0/GH 5 D 3.4/GH 3 D 3.4/GH 5 D 3.8/GH 3 D 3.8/GH 5 D 4.5/GH 3 D 4.5/GH 5 D 5.5/GH 3 D 5.5/GH 5

The Transfer Coping GH 3 is used for gingiva up to 3 mm thick. Please use the Transfer Coping GH 5 for gingiva exceeding 3 mm thickness.

GH 3
3 mm

GH 5
5 mm

46

Order No.

Article FRIADENT Transfer Coping (Transfer Technique) with Standard Abutment Screw4 (D 3.0 with Abutment Screw4 D 3.0) and TransferCap20 (D 3.0 D 5.5)

45 1620 45 1621 45 1630 45 1631 45 1640 45 1641 45 1650 45 1651 45 1660 45 1661

D 3.0/GH 3 4 D 3.0/GH 5 4 D 3.4/GH 3 4 D 3.4/GH 5 4 D 3.8/GH 3 2 D 3.8/GH 5 2 D 4.5/GH 3 2 D 4.5/GH 5 2 D 5.5/GH 3 2 D 5.5/GH 5 2

FRIADENT Transfer Coping (PickUp Technique) with PickUp Guide Pin4 (D 3.0 with PickUp Guide Pin4 D 3.0) and TransferCap20 (D 3.0 D 5.5) 45 1625 45 1622 45 1635 45 1632 45 1645 45 1642 45 1655 45 1652 45 1665 45 1662 D 3.0/GH 3 4 D 3.0/GH 5 4 D 3.4/GH 3 4 D 3.4/GH 5 4 D 3.8/GH 3 2 D 3.8/GH 5 2 D 4.5/GH 3 2 D 4.5/GH 5 2 D 5.5/GH 3 2 D 5.5/GH 5 2

FRIADENT Transfer Coping Slim2 45 1239 45 1249 45 1259 D 3.4 D 3.8 D 4.5

The FRIADENT Transfer Coping Slim is used if in cases with limited mesiodistal space the contouring of the soft tissue has been made with the Gingiva Former Slim (see page 44).

47

FRIADENT Prosthetics

for FRIALIT & XiVE S

Prosthetic fabrication at implant level:

Impressions
Order No. Article FRIADENT Transfer Coping Basic2 46 46 46 46 1632 1642 1652 1662 D 3.4 D 3.8 D 4.5 D 5.5

The FRIADENT Transfer Coping Basic is used for simple impression making in cases with implant divergencies.

46 4304 45 4305 46 1605 45 1615

FRIADENT Standard Abutment Screw 4 D 3.0 FRIADENT Standard Abutment Screw4 FRIADENT PickUp Guide Pin4 D 3.0 FRIADENT PickUp Guide Pin4

Abutment screws and guide pins are seated with the 0.9 mm FRIADENT Hex Driver or with the blade width 2.0 mm FRIADENT Slot Screwdriver (see page 70).

TransferCaps

FRIADENT TransferCaps allow for greater precision during impression so that the implant inner geometry is transferred with even greater accuracy. The result is the best possible superstructure fit. FRIADENT TransferCaps are not available for diameter D 6.5.
FRIADENT Multi-Pack TransferCap20 (3 pieces) 45 45 45 45 45 1629 1639 1649 1659 1669 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

Please note: D 3.0 components (bronze) can only be used for XiVE. FRIALIT implants D 6.5 (green) are restored with D 5.5 abutments.

48

Prosthetic fabrication from the implant level:

Prosthetics/laboratory
Order No. Article FRIADENT Implant Analog5 45 45 45 45 45 45 4020 4030 4040 4050 4060 4070 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5

Try-in Abutments

Gingival height, angle and the correct position of the horizontal screw (GH 2) for FRIADENT abutments can easily and quickly be determined with the FRIADENT Select Try-in Abutments.
FRIADENT Select Try-in Abutment2 45 45 45 45 45 45 45 45 2119 2120 2121 2122 2123 2219 2220 2221 3.0/A 3.4/A 3.8/A 4.5/A 5.5/A 3.0/A 3.4/A 3.8/A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 0 (straight) 15 (angled 15) 15 (angled 15) 15 (angled 15)

FRIADENT Select Try-in Abutment Multi-Pack2 (3 pieces) 45 45 45 45 45 45 2193 2194 2195 2196 2293 2294 D D D D D D 3.4/A 3.8/A 4.5/A 5.5/A 3.4/A 3.8/A 0 (straight, 3 pieces) 0 (straight, 3 pieces) 0 (straight, 3 pieces) 0 (straight, 3 pieces) 15 (angled, 3 pieces) 15 (angled, 3 pieces)

49

FRIADENT Prosthetics

D D D D D D D D

for FRIALIT & XiVE S

Prosthetic fabrication at implant level:

Prosthetics/laboratory
Abutments for single tooth restorations and bridges
Order No. Article

EstheticBase Abutments FRIADENT EstheticBase straight / A 0 Screw for EstheticBase4 (D 3.0 with Abutment Screw4 D 3.0) 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 2121 2122 2123 2125 2131 2132 2133 2135 2141 2142 2143 2145 2151 2152 2153 2155 2161 2162 2163 2165 D D D D D D D D D D D D D D D D 3.0/GH 3.0/GH 3.0/GH 3.0/GH 3.4/GH 3.4/GH 3.4/GH 3.4/GH 3.8/GH 3.8/GH 3.8/GH 3.8/GH 4.5/GH 4,5/GH 4.5/GH 4.5/GH 5.5/GH 5.5/GH 5.5/GH 5.5/GH 14 24 34 54 14 24 34 54 12 22 32 52 12 22 32 52 12 22 32 52

GH 1 GH 2 GH 3 GH 5 1 mm 2 mm 3 mm 5 mm All FRIADENT EstheticBase Abutments are provided with a horizontal thread (M 1.4). An additional horizontal or transverse screw set is necessary for horizontally screw-retained crowns (see page 52).

D D D D

We recommend the use of special titanium drills (Gebr. Brasseler, Lemgo or Jota Dsseldorf) for preparing the abutments.
Abutment screws 46 4304 46 4305 FRIADENT Standard Abutment Screw4 D 3,0 FRIADENT Screw4 for EstheticBase

Please note: D 3.0 components (bronze) can only be used for XiVE. FRIALIT implants D 6.5 (green) are restored with D 5.5 abutments.

50

Order No.

Article FRIADENT EstheticBase angled / A 15 Screw for EstheticBase4 (D 3.0 with Abutment Screw4 D 3.0)

46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46

2221 2222 2223 2225 2231 2232 2233 2235 2241 2242 2243 2245 2251 2252 2253 2255 2261 2262 2263 2265

D D D D D D D D D D D D D D D D

3.0/GH 3.0/GH 3.0/GH 3.0/GH 3.4/GH 3.4/GH 3.4/GH 3.4/GH 3.8/GH 3.8/GH 3.8/GH 3.8/GH 4.5/GH 4.5/GH 4.5/GH 4.5/GH 5.5/GH 5.5/GH 5.5/GH 5.5/GH

14 24 34 54 14 24 34 54 12 22 32 52 12 22 32 52 12 22 32 52

D D D D

Horizontal screws 46 4403 46 4404 46 4407 46 4408 46 4401 46 4402 46 4405 46 4406 45 4410 FRIADENT Horizontal Screw Set Standard with Horizontal Screw Standard4 and Horizontal Screw Seat8 FRIADENT Horizontal Screw Set Long with Horizontal Screw Long4 and Horizontal Screw Seat8 FRIADENT Transverse Screw Set Standard with Transversal Screw Standard4 and Horizontal Screw Seat8 FRIADENT Transverse Screw Set Long with Transversal Screw Long4 and Horizontal Screw Seat8 FRIADENT Horizontal Screw Standard4 FRIADENT Horizontal Screw Long4 FRIADENT Transverse Screw Standard4 FRIADENT Transverse Screw Long4 FRIADENT Horizontal Screw Seat8

Horizontal screws are seated in with the 0.9 mm FRIADENT Hex Driver (see page 64). Particularly for molars, the use of the Horizontal Screw Set with a long head is recommended, as the crown usually requires broader buccal-lingual width.

51

FRIADENT Prosthetics

for FRIALIT & XiVE S

Prosthetic fabrication at implant level:

Prosthetics/laboratory
Abutments for single tooth restorations and bridges
Order No. Article

Ceramic Abutments FRIADENT CERCON Abutment32 straight / A 0 with Screw 47 1141 47 2141 47 1151 47 2151 47 1142 47 2142 47 1152 47 2152 D 3.8/GH1, neutral D 3.8/GH1, dentin D 4.5/GH1, neutral D 4.5/GH1, dentin D 3.8/GH2, neutral D 3.8/GH2, dentin D 4.5/GH2, neutral D 4.5/GH2, dentin FRIADENT CERCON Abutment32 angled / A 15 with Screw 47 1241 47 2241 47 1251 47 2251 47 1242 47 2242 47 1252 47 2252 D 3.8/GH1, neutral D 3.8/GH1, dentin D 4.5/GH1, neutral D 4.5/GH1, dentin D 3.8/GH2, neutral D 3.8/GH2, dentin D 4.5/GH2, neutral D 4.5/GH2, dentin

We recommend using the ceramic-line Shaping Set of DeguDent for prepping the FRIADENT CERCON Abutments. The grinding process of the CERCON Abutments requires irrigation. Please note that the indication is restricted to the front tooth region.

FRIADENT CeraBase Abutment with Standard Abutment Screw4, 45 2530 45 2531 45 2540 45 2541 45 2550 45 2551 45 2560 45 2561 D 3.4 conical 30/4 D 3.4 anatomical30/4 D 3.8 conical 30/3 D 3.8 anatomical30/3 D 4.5 conical 30/3 D 4.5 anatomical30/3 D 5.5 conical 30/3 D 5.5 anatomical30/3

We recommend using the FRIADENT CeraBase Tool Set for prepping the ceramic sleeve of the FRIADENT CeraBase Abutment (see page 65). The grinding process does not require irrigation.

52

Order No.

Article

Cast-to Abutments FRIADENT AuroBase20/8 Abutment with Standard Abutment Screw4 (D 3.0 with Abutment Screw4 D 3.0) 45 45 45 45 45 2420 2430 2440 2450 2460 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

Telescopic Abutments FRIADENT Telescopic Abutment with Standard Abutment Screw4 (D 3.0 with Abutment Screw4 D 3.0) 45 45 45 45 45 2620 2630 2640 2650 2660 D 3.0 4 D 3.4 4 D 3.8 2 D 4.5 2 D 5.5 2

The Telescopic Abutment can also be used as a custom abutment for single crowns. The Telescopic Abutment can be veneered with titanium ceramics (e.g., Duceratin, Ducera or Vita Titankeramik, Vita Zahnfabrik) for occlusally screw-retained single crowns.

Abutment screws 46 4304 46 4305 FRIADENT Standard Abutment Screw4 D 3.0 FRIADENT Screw4 for EstheticBase

Milling Implants FRIADENT Milling Implant6 45 45 45 45 45 2621 2631 2641 2651 2661 D 3.0 D 3.4 D 3.8 D 4.5 D 5.5

53

FRIADENT Prosthetics

for FRIALIT & XiVE S

Prosthetic fabrication at implant level:

Prosthetics/laboratory
Attachments
Order No. Article FRIADENT Ball and Socket Attachment Insert2, Attachment Screw2, Socket9 (gold alloy), with blue silicone ring and white plastic ring 45 3131 45 3132 45 3133 45 45 45 45 45 45 45 45 45 45 45 45 3141 3142 3143 3145 3151 3152 3153 3155 3161 3162 3163 3165 D 3.4/GH 1 4 D 3.4/GH 2 4 D 3.4/GH 3 4 D D D D D D D D 3.8/GH 3.8/GH 3.8/GH 3.8/GH 4.5/GH 4.5/GH 4.5/GH 4.5/GH 5.5/GH 5.5/GH 5.5/GH 5.5/GH 12 22 32 52 12 22 32 52 12 22 32 52

D D D D

The gingival collar section of the FRIADENT Ball and Socket Attachment is positioned using the FRIADENT Seating Instrument for Attachment Insert and MP Insert. The Attachment Screw is seated in the implant using the 1.22 mm FRIADENT Hex Driver (see page 70).

45 3200 45 4105

FRIADENT Attachment Matrix9 FRIADENT Attachment Patrix Analog universal

The FRIADENT Attachment Patrix Analog is used to repair and reline overdentures. The Analog is snapped into the socket in the denture base after reline impressions are made. One Patrix Analog is used for all diameters.

54

Prosthetic fabrication at gingival level (MP Abutment):

Transgingival extension, temporary sealing


Order No. Article FRIADENT MP Abutment2 MP Abutment Insert and MP Insert Screw 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 2831 2832 2833 2835 2841 2842 2843 2845 2849 2851 2852 2853 2855 2859 2861 2862 2863 2865 D D D D D D D D D D D D D D 3.4/GH 3.4/GH 3.4/GH 3.4/GH 3.8/GH 3.8/GH 3.8/GH 3.8/GH 3.8/GH 4.5/GH 4.5/GH 4.5/GH 4.5/GH 4.5/GH 5.5/GH 5.5/GH 5.5/GH 5.5/GH 1 2 3 5 1 2 3 5 9 1 2 3 5 9 1 2 3 5

D D D D

The appropriate MP Abutment Insert is selected according to the gingival height. The number of the grooves on the screw head indicates the gingival height of the matching MP Abutment Insert. GH 1 = 1 ring GH 2 = 2 rings GH 3 = 3 rings GH 5 = 5 rings

The MP Abutment Inserts are mounted on the implants with the Seating Instrument for Attachment Insert and MP Insert. The MP Abutment Screw is tightened with the MP Abutment Screw Driver for ratchet or handpiece (see page 65).

55

FRIADENT Prosthetics

for FRIALIT & XiVE S

Prosthetic fabrication at gingival level (MP Abutment):

Transgingival extension, temporary sealing


Order No. Article FRIADENT MP Cover Screw2 46 46 46 46 1430 1440 1450 1460 D 3.4 D 3.8 D 4.5 D 5.5

Please note: D 3.0 components (bronze) can only be used for XiVE. FRIALIT implants D 6.5 (green) are restored with D 5.5 abutments.

56

Prosthetic fabrication at gingival level (MP Abutment):

Impressions
Order No. Article

FRIADENT MP Lab Set Transfer Impression Content: MP Transfer Impression Coping, MP Analog 46 46 46 46 8130 8140 8150 8160 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT MP Lab Set PickUp Impression Content: MP PickUp Impression Coping, MP PickUp Guide Pin, MP Analog 46 46 46 46 8230 8240 8250 8260 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT MP Transfer Impression Coping2 46 46 46 46 1635 1645 1655 1665 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT MP PickUp Impression Coping2 46 46 46 46 1630 1640 1650 1660 D 3.4 D 3.8 D 4.5 D 5.5

46 1615

FRIADENT MP PickUp Guide Pin4

We recommend securing the MP PickUp Guide Pin with the width 1.22 mm FRIADENT Hex Driver (see page 70).

FRIADENT MP Analog5 46 46 46 46 4030 4040 4050 4060 D 3.4 D 3.8 D 4.5 D 5.5

57

FRIADENT Prosthetics

for FRIALIT & XiVE S

Prosthetic fabrication at gingival level (MP Abutment):

Prosthetics/laboratory
Bridges
Order No. Article

FRIADENT MP Lab Set Bridge with Castable Waxing Sleeve Content: Castable Waxing Sleeve, MP Screw for Waxing Sleeve 46 46 46 46 9530 9540 9550 9560 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT MP Lab Set Bridge with Cast-to Waxing Sleeve Content: Cast-to Waxing Sleeve, MP Screw for Waxing Sleeve 46 46 46 46 9930 9940 9950 9960 D 3.4 D 3.8 D 4.5 D 5.5

Please note: D 3.0 components (bronze) can only be used for XiVE. FRIALIT implants D 6.5 (green) are restored with D 5.5 abutments.

58

Order No.

Article

Waxing Sleeves FRIADENT Castable Waxing Sleeve21 45 45 45 45 4330 4340 4350 4360 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT Cast-to Waxing Sleeve21/8 45 45 45 45 4630 4640 4650 4660 D 3.4 D 3.8 D 4.5 D 5.5

Cast-to Waxing Sleeve: Smoothing with finishers is not necessary.

46 4300

FRIADENT MP Screw for Castable Waxing Sleeve4

We recommend using the 1.22 mm FRIADENT Hex Driver (see page 64) when seating the Screw for the Waxing Sleeve.

Soldering Analogs 45 4102 FRIADENT Lab Set Soldering Analog for Bridge FRIADENT Soldering Analog, universal and Soldering Screw for Bridge FRIADENT Soldering Analog6, universal FRIADENT Soldering Screw for Bridge4

45 4103 45 4207

59

FRIADENT Prosthetics

for FRIALIT & XiVE S

Castable Waxing Sleeve: Prior to bridge delivery, smooth the contact surface between crown and abutment and the screw and screw seat using the FRIADENT Finishers (see page 65).

Prosthetic fabrication at gingival level (MP Abutment):

Prosthetics/laboratory
Bars
Order No. Article

FRIADENT MP Lab Set Gold Bar Coping Content: Gold Bar Coping9, MP Screw for Bar Coping 46 46 46 46 9630 9640 9650 9660 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT MP Lab Set Titanium Bar Coping Content: Titanium Bar Coping, MP Screw for Bar Coping 46 46 46 46 9637 9647 9657 9667 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT MP Lab Set Castable Bar Coping Content: Castable Bar Coping, MP Screw for Bar Coping 46 46 46 46 9638 9648 9658 9668 D 3.4 D 3.8 D 4.5 D 5.5

Bar Copings FRIADENT Gold Bar Coping9 (without screw), for soldering 45 45 45 45 4230 4240 4250 4260 D 3.4 D 3.8 D 4.5 D 5.5

FRIADENT Titanium Bar Coping2 (without screw) 45 45 45 45 4231 4241 4251 4261 D 3.4 D 3.8 D 4.5 D 5.5

60

Order No.

Article FRIADENT Castable Bar Coping21 (without screw)

45 45 45 45

4530 4540 4550 4560

D 3.4 D 3.8 D 4.5 D 5.5

46 4200

FRIADENT MP Coping Screw4

We recommend using the 1.22 mm FRIADENT Hex Driver when seating MP Coping Screw (see page 64).

Accessories

45 4215

FRIADENT Gold Bar Clip9 50 mm length FRIADENT Titanium Bar round2 50 mm length

45 4212

Soldering Analogs 45 4101 FRIADENT Lab Set Soldering Analog for Bar FRIADENT Soldering Analog, universal and Soldering Screw for Bar FRIADENT Soldering Analog6, universal FRIADENT Soldering Screw for Bar4

45 4103 45 4206

61

FRIADENT Prosthetics

for FRIALIT & XiVE S

45 4210

FRIADENT Gold Bar round9 50 mm length

Instrument sets impression/prosthetics


Order No. Article

46 7000

FRIADENT Prosthetic Set Mini The Prosthetic Set Mini includes all instruments needed for the prosthetic delivery of implant restorations. Content: FRIADENT Ratchet Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 1.22 mm/short

45 8111

FRIALIT Basic Set Prosthetics The set includes all clinical instruments necessary for impression making and prosthetics. The instruments are supplied in the FRIALIT Prosthetic Tray. Content: FRIADENT Ratchet Handpiece Hex Driver 0.9 mm Handpiece Hex Driver 1.22 mm Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 1.22 mm/short Ratchet Hex Driver 1.22 mm/long Ratchet Slot Screwdriver 2.0 mm/long Seating Instrument for Transfer Coping and MH-6 Abutment/A 0 Seating Instrument for Attachment Insert and MP Insert Handpiece Seating Instrument for MP Insert Screw Ratchet Seating Instrument for MP Insert Screw

48 0030

FRIALIT Prosthetic Tray (empty)

62

Order No.

Article

26 8020

XiVE Prosthetic Tray The set includes all clinical instruments necessary for impression making and prosthetics. The instruments are supplied in the XiVE Prosthetic Tray. Content: FRIADENT Ratchet Handpiece Hex Driver 0.9 mm/short Handpiece Hex Driver 0.9 mm/long Handpiece Hex Driver 1.22 mm/short Handpiece Hex Driver 1.22 mm/long Handle for Handpiece Hex Driver Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 0.9 mm/long Ratchet Hex Driver 1.22 mm/short Ratchet Hex Driver 1.22 mm/long Seating Instrument for Attachment Insert and MP Insert Handpiece Seating Instrument for MP Insert Screw Ratchet Seating Instrument for MP Insert Screw Insertion Tool EstheticBase FRIADENT Select Try-in Abutment D 3.0/A 0 FRIADENT Select Try-in Abutment D 3.4/A 0 FRIADENT Select Try-in Abutment D 3.8/A 0 FRIADENT Select Try-in Abutment D 4.5/A 0 FRIADENT Select Try-in Abutment D 5.5/A 0 FRIADENT Select Try-in Abutment D 3.0/A 15 FRIADENT Select Try-in Abutment D 3.4/A 15 FRIADENT Select Try-in Abutment D 3.8/A 15

26 8025

XiVE Prosthetic Tray (empty)

63

FRIADENT Prosthetics

for FRIALIT & XiVE S

Instruments for impression/ prosthetics/laboratory


Order No. 45 5709 Article FRIADENT Ratchet6, without inserts FRIADENT Ratchet Hex Driver6 with torque limit width 0.9 mm/14 Ncm/short width 0.9 mm/14 Ncm/long width 1.22 mm/24 Ncm/short width 1.22 mm/24 Ncm/long FRIADENT Ratchet Slot Screwdriver6 with torque limit blade width 2.0 mm/14 Ncm/short blade width 2.0 mm/14 Ncm/long FRIADENT Handpiece Hex Driver6 width 0.9 mm/short width 0.9 mm/long width 1.22 mm/short width 1.22 mm/long FRIADENT Handpiece Slot Screwdriver6 blade width 2.0 mm/short blade width 2.0 mm/long FRIADENT Handle for Handpiece Hex Driver6

45 45 45 45

5732 5733 5734 5736

45 5714 45 5722

46 46 46 46

5710 5720 5711 5721

46 5712 46 5722 46 5750

This handle fits all handpiece drivers.


FRIADENT Hex Driver6 without torque limit width 0.9 mm

45 5650

The 0.9 mm FRIADENT Hex Driver without torque limit is recommended for regions with limited access.

64

Order No. 45 5605

Article FRIADENT Seating Instrument for Transfer Coping and MH-6 Abutment /A 0 FRIADENT Finisher6/10 for Horizontal Screw Seat FRIADENT Hermetics Basic Set (Seating Instrument, 20 Hermetics Sealing Rings) FRIADENT Hermetics Seating Instrument2 FRIADENT CeraBase Tool Set Contents: Medium Diamond Drill, Fine Diamond Drill, Rubber Polishing Wheel FRIADENT CeraBase Medium Diamond Drill

45 5702 45 5600

45 5601 45 5750

45 5753 45 5755 45 5758 45 5617

FRIADENT CeraBase Rubber Polishing Wheels (5 pieces) FRIADENT Seating Instrument2 for Attachment Insert and MP Insert FRIADENT Ratchet Seating Instrument6 for MP Insert Screw FRIADENT Handpiece Seating Instrument for MP Insert Screw FRIADENT Activator6 for Ball and Socket Attachment FRIADENT Deactivator6 for Ball and Socket Attachment FRIADENT Bar Clip Activator6 FRIADENT Finisher6/10 for Abutment Seat for screw-retained superstructures D 3.4 D 4.5 D 5.5 FRIADENT Finisher6/10 for Screw Head Seat for screw-retained superstructures

46 5610

46 5615

45 5621 45 5622 45 5623

45 5705 45 5707 45 5700

65

FRIADENT Prosthetics

for FRIALIT & XiVE S

FRIADENT CeraBase Fine Diamond Drill

XiVE TG

XiVE TG plus the transgingival alternative

If function is the first priority, then the single-component transgingival XiVE TG plus implant is recommended. As a leader in innovation, DENTSPLY Friadent accepts the obligation to apply new scientific insights to the development of existing and new implant systems. XiVE TG plus is the result of the scientific and clinical experience accumulated with the New Ledermann Screw and FRIALOC systems. With the implant-abutment connection and the machined implant collar extending through the soft tissue, the transgingival implant looks like a XiVE S plus implant with an integrated MP abutment.

66

Indications
Cases: where a transgingival implant design is indicated when temporary and definitive components are needed for simple and fast prosthetic restoration requiring increased primary stability for early or immediate implant function with atrophied ridges where augmentation is not desired or indicated, multiple implant restorations in posterior regions where a cylindrical implant design is advantageous particularly in the lateral region where the local bone must be used to the maximum possible extent: implant lengths available range from 8 to 18 mm

Macro-design
The cylinder-shaped design for internal condensation of the peri-implant bone prevents trauma and increases primary stability of implants, even in spongy bone.

Micro-design
The innovative thread design of XiVE screw implants combined with the bone-class-specific preparation of the implant site provides torque stabilization in all bone qualities.

Nano-design

Implant diameter D 3.4 XiVE TG

D 3.8

D 4.5

The XiVE TG product range is a further development of the FRIALOC implant system. All XiVE TG components and instruments (except the drills) are fully compatible with FRIALOC. Previously placed FRIALOC implants can still be restored with components of the XiVE TG prosthetic line.

67

XiVE TG

Growth-activating FRIADENT plus surface. Transgingival Screw implant with trimodal surface morphology providing an ideal environment for functional adaptation of epithelium, connective tissue and bone.

Implant placement

XiVE TG sterile packaging for implants

No-touch insertion XiVE TG plus Transgingival Screw Implant


1. Remove the outer vial cap (non-sterile) and drop the sterile inner vial onto the surgical tray. 2. Place the XiVE TG Ratchet or Handpiece Implant Driver onto the Adapter Screw.

All FRIADENT Screw Implants are packed in gamma sterilized, transparent double vials. The color-coded cap is sealed with an adhesive label.

Transparent outer vial to see the content Color-coded cap displaying the implant length for clear identification Sterile inner vial with implant retaining stopper for fast and safe no-touch placement of implants Peel-off labels for a reliable documentation

3. Remove the implant without touching the inner vial.

The undamaged label clearly indicates that the sterile package has not been opened and thus product sterility.

4. Remove the Implant Holder.

5. Place XiVE TG plus Screw Implant. Please follow the instructions for use.

68

Order No.

Article

For the pre-surgical planning of XiVETG plus, the same components as for XiVES Screw Implants are used (see pages 22/23).
Implants (sterile) XiVE TG plus Transgingival Screw Implant Screw Implant3, Adapter Screw 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 1431 1432 1433 1435 1438 1440 1441 1442 1443 1445 1448 1450 1451 1452 1453 1455 1458 D D D D D D D D D D D D D D D D D 3.4/L 3.4/L 3.4/L 3.4/L 3.4/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 3.8/L 4.5/L 4.5/L 4.5/L 4.5/L 4.5/L 4.5/L 9.5 11 13 15 18 8 9.5 11 13 15 18 8 9.5 11 13 15 18

An Adapter Screw is pre-mounted on XiVE TG plus Screw Implants to secure the Implant Driver. Use the XiVE TG Ratchet or Handpiece Implant Driver (see page 76) to thread in the XiVE TG Implants. After rotating in the implant, the Adapter Screw is removed with the 0.9 mm FRIADENT Hex Driver.

25 9200

XiVE TG Clinical Set Cover Screw (Four Cover Screws)

25 1400

XiVE TG Cover Screw for Implants2

The Cover Screws are placed with the 0.9 mm FRIADENT Hex Driver.

69

XiVE TG

Instruments

Order No.

Article

XiVE Instrument Sets Surgery The XiVE Instrument Sets Surgery contain the instruments required for implant placement (see page 30). The kits are supplied in the XiVE Surgical Tray. 26 8000 26 8005 XiVE ExpertSet Surgery5/6/26 XiVE StandardSet Surgery5/6/26

Drills and drill sequence for transgingival XiVE TG Implants are identical to those of subgingival XiVE S Implants (see page 28/29). XiVE BoneCondenser may also be used (see page 35).

Other Instruments 25 5206 45 5709 25 5600 25 5601 XiVE TG Radiographic Template (transgingival) FRIADENT Ratchet6, without inserts XiVE TG Ratchet Implant Driver6 XiVE TG Handpiece Implant Driver6 FRIADENT Ratchet Hex Driver6 with torque limit width 0.9 mm/14 Ncm/short width 0.9 mm/14 Ncm/long width 1.22 mm/24 Ncm/short width 1.22 mm/24 Ncm/long FRIADENT Handpiece Hex Driver6 width 0.9 mm/short width 0.9 mm/long width 1.22 mm/short width 1.22 mm/long

45 45 45 45

5732 5733 5734 5736

46 46 46 46

5710 5720 5711 5721

70

XiVE TG Prosthetics
Components are selected based on the prosthetic concept.

Impressions

Single Crowns

Bridges

Overdentures

XiVE TG Transfer Impression Coping

XiVE TG Abutment straight or angled 15

XiVE TG Abutment straight or angled 15

XiVE TG Gold, Titanium or Castable Bar Coping

XiVE TG PickUp Impression Coping

XiVE TG AuroBase

XiVE TG Waxing Sleeves

XiVE TG Attachment

The XiVE TG product range is a further development of the FRIALOC implant system. All XiVE TG components and instruments (except the drills) are fully compatible with FRIALOC. Previously placed FRIALOC implants can still be restored with components of the XiVE TG prosthetic line.

71

XiVE TG

Impressions

Order No.

Article

25 9100

XiVE TG Clinical Set Transfer Impression D 3.4 D 4.5 (Four Transfer Impression Copings )

25 9105

XiVE TG Clinical Set Transfer Impression (short) D 3.4 D 4.5 (Four Short Transfer Impression Copings)

25 9112

XiVE TG Clinical Set PickUp Impression D 3.4 D 4.5 (Four PickUp Impression Copings with four TG PickUp Guide Pins)

25 1600

XiVE TG Transfer Impression Coping2 D 3.4 D 4.5 XiVE TG Transfer Impression Coping (short)2 D 3.4 D 4.5

25 1605

The short Impression Copings are used for making the impression with an existing prosthesis.
25 1805 XiVE TG PickUp Impression Coping2 D 3.4 D 4.5 with PickUp Guide Pin XiVE TG PickUp Guide Pin4

25 1701

If, in cases of implant divergencies, a transfer of the square head is not required, please use the FRIADENT MP Transfer Impression Coping D 3.8 (Order no. 46 1640, see page 57). This impression coping is compatible with all diameters of XiVE TG.

72

Prosthetics/laboratory

Order No.

Article

25 9405

XiVE TG Implant-Soldering Analog Multipack D 3.4 D 4.5 (Four TG Implant-Soldering Analogs)

25 4010

XiVE TG Implant-Soldering Analog6 D 3.4 D 4.5

Bridges
Order No. Article

25 9900

XiVE TG Lab Set Bridge (Castable Waxing Sleeve) D 3.4 D 4.5 (Four TG Castable Waxing Sleeves, four TG Abutment Screws)

25 9905

XiVE TG Lab Set Bridge (Cast-to Waxing Sleeve) D 3.4 D 4.5 (Four TG Cast-to Waxing Sleeves, four TG Abutment Screws)

25 4245

XiVE TG Castable Waxing Sleeve21 D 3.4 D 4.5 with TG Abutment Screw

25 4300

XiVE TG Abutment Screw4 D 3.4 D 4.5

Soldering Analogs 25 9305 XiVE TG Lab Set Implant-Soldering Analog (Bridge) D 3.4 D 4.5 (Four TG Implant-Soldering Analogs, four TG Abutment Screws) XiVE TG Lab Set Soldering Analog Bridge D 3.4 D 4.5 TG Implant-Soldering Analog with TG Abutment Screw

25 4105

The TG Soldering Analog is used for securing the framework in the soldering base.

73

XiVE TG

25 4246

XiVE TG Cast-to Waxing Sleeve21/8 D 3.4 D 4.5 with TG Abutment Screw

IMZ-TwinPlus

Prosthetics/laboratory
Bridges and single crowns
Order No. 25 4500 Article XiVE TG Abutment straight2 D 3.4 D 4.5 (straight) with TG Abutment Screw XiVE TG Abutment angled 152 D 3.4 D 4.5 (angled 15) with TG Abutment Screw

25 4510

All straight and angled TG Abutments are provided with a horizontal thread (M 1.4). An additional horizontal or transverse screw set is necessary for horizontally screw-retained crowns (see page 51). We recommend the use of special titanium drills (Gebr. Brasseler, Lemgo or Jota Dsseldorf) for preparing the abutments.

25 4520

XiVE TG AuroBase20/8 D 3.4 D 4.5 with TG Abutment Screw XiVE TG Abutment Screw4

25 4300

25 4401

XiVE TG Attachment2/4 D 3,4 D 4,5

74

Overdentures
Order No. Article

25 9600

XiVE TG Lab Set Gold Bar Coping9 D 3.4 D 4.5 (Four TG Gold Copings, four TG Coping Screws)

25 9700

XiVE TG Lab Set Titanium Bar Coping D 3.4 D 4.5 (Four TG Titanium Copings, four TG Coping Screws)

25 9800

XiVE TG Lab Set Castable Coping D 3.4 D 4.5 (Four TG Castable Copings, four TG Coping Screws)

25 4240

XiVE TG Gold Bar Coping9 D 3.4 D 4.5 with TG Coping Screw XiVE TG Titanium Bar Coping2 D 3.4 D 4.5 with TG Coping Screw XiVE TG Castable Bar Coping21 D 3.4 D 4.5 with TG Coping Screw XiVE TG Coping Screw4

25 4241

25 4242

25 4200

Accessories 45 4210 45 4212 45 4215

FRIADENT Titanium Bar round2 50 mm length FRIADENT Gold Bar Clip9 50 mm length

Soldering Analogs

25 9306

XiVE TG Lab Set Implant-Soldering Analog (Bar) D 3.4 D 4.5 (Four TG Implant-Soldering Analogs, four TG Coping Screws)

25 4106

XiVE TG Lab Set Soldering Analog Bar D 3.4 D 4.5 TG Implant-Soldering Analog with TG Coping Screw

75

XiVE TG

FRIADENT Gold Bar round9 50 mm length

IMZ-TwinPlus

Instruments for impression/ prosthetics/laboratory


Order No. 45 5709 Article FRIADENT Ratchet6, without inserts FRIADENT Ratchet Hex Driver6 with torque limit width 0.9 mm/14 Ncm/short width 0.9 mm/14 Ncm/long width 1.22 mm/24 Ncm/short width 1.22 mm/24 Ncm/long FRIADENT Handpiece Hex Driver6 width 0.9 mm/short width 0.9 mm/long width 1.22 mm/short width 1.22 mm/long FRIADENT Handle for Handpiece Hex Driver6

45 45 45 45

5732 5733 5734 5736

46 46 46 46

5710 5720 5711 5721

46 5750

This handle fits all handpiece drivers.


25 5705 XiVE TG Finisher

76

77

XiVE TG

Presentation material

Order No. 45 9992 45 9981 45 9982 45 9985 45 9986 26 9110

Article Large scale model FRIALIT Synchro 5 :1 (with crown) FRIADENT Acrylic model maxilla without prosthetics (ANKYLOS, FRIALIT, XiVE) FRIADENT Acrylic model maxilla with prosthetics (ANKYLOS, FRIALIT, XiVE) XiVE Acrylic model mandible without prosthetics (bar construction) XiVE Acrylic model mandible with prosthetics (bar construction) XiVE Large Scale Model Set 5:1

CD-ROMs for Presentation

Each CD-ROM contains Powerpoint Presentations and high-resolution picture files for the exposing of slides
66 1035 66 4037 66 4038 66 4039 66 7010 66 4036 66 4501 66 1036 66 1037 66 1038 66 1067 66 1066 CD-ROM FRIALIT Basics Surgery and Prosthetics CD-ROM FRIALIT Synchro, FRIALIT BoneProfiler CD-ROM FRIALIT MP-Abutment CD-ROM FRIALIT Select CD-ROM XiVE, PowerPoint presentation and slides CD-ROM FRIALIT Video Sequences in PowerPoint CD-ROM, Picture CD FRIALIT/XiVE CD-ROM, Picture CD DENTSPLY Friadent CD-ROM, Picture CD CERCON plus CD-ROM, Picture CD Internet, all Systems CD-ROM CERCON, PowerPoint presentation CD-ROM FRIADENT plus, PowerPoint presentation

Videos 66 4046 66 4047 5 701012 FRIALIT System Video (English, PAL) FRIALIT System Video (English, NTSC) Implant Passport XiVE

78

Materials
Metals
Type Titanium Titanium Titanium Titanium Aluminium Stainless steel Brass Cast-to alloy* Gold alloy ** Hard metal Index 1 2 3 4 5 6 7 8 9 10 Composition Ti grade 1 Ti grade 2 Ti grade 4 Ti6AL4V AlMg3 DIN 1.4305 CuZn Au: 60%, Pt: 19%, Pd: 20%, Ir: 1% Au: 68.6%, Pt: 2.4%, Pd: 4%, Ag: 11.8%, Cu: 10.6%, Ir: 0.1%, Zn: 2.5% K 40

* TEC 11.9 x 10-6 K-1, pre-heating temperature < 850C, cast temperature < 1450C ** melting interval from 880 940C

Plastics
Type Polyoxymethylene Polymethylmethacrylate Polystyrene Polytetrafluourethylene Polyetheretherketone Polyetherimide Silicone Polycarbonate Polypropylene Index 20 21 22 23 24 25 26 27 28

Ceramics
Typ Aluminium oxide Hydroxyapatite Zirconium oxide Index 30 31 32 Composition Al2O3 Ca5(PO4)3OH ZrO2

79

Presentation material

80

81

82

FRIADENT Class l Medical Devices In terms of the Directive 93/42/EEC Class l Medical Devices are: Non-active hand-held surgical and prosthetic instruments for implant placement and augmentation Components for impression technique, which do not remain in the patients mouth Non-active components for the planning stage FRIADENT Class lla, llb and lll Medical Devices

0123

In terms of the Directive 93/42/EEC Class lla, llb and lll Medical Devices are: Dental Implants, membranes, membrane nails as well as bone reconstruction materials Active surgical and prosthetic instruments for implant placement and augmentation Components for impression technique and prosthetic overdenture, which remain in the patients mouth Manufacturer: FRIADENT GmbH P. O. Box 71 01 11 68221 Mannheim/Germany Phone: + 49 621 4302-1288 Fax: + 49 621 47 13 06 e-Mail: info@friadent.de Internet: http://www.friadent.de

83

Order No. 6-452001/009


060709/SB

Manufacturer: FRIADENT GmbH P. O. Box 71 01 11 68221 Mannheim/Germany Phone: + 49 621 4302-1288 Fax: + 49 621 47 13 06 e-Mail: info@friadent.de Internet: http://www.friadent.de